Climapro2RF
www.glow-worm.co.uk
Installation
Wireless room thermostatwith receiver
- 1 -
INTRODUCTION
1 Instructionsguidance.........................................................................................................................31.1 Productdocumentation...........................................................................................31.2 Associateddocuments...........................................................................................31.3 Explanationofsymbols...........................................................................................3
2 Climapro2RFdescription...................................................................................................................32.1 Regulationandstatutoryrequirements..................................................................32.2 OperationalDiagram..............................................................................................3
3 Safetyinstructionsandregulations....................................................................................................33.1 Safetyregulations...................................................................................................33.2 Regulations.............................................................................................................4
4 Recycling...........................................................................................................................................44.1 Climapro2RF..........................................................................................................44.2 Packaging...............................................................................................................4
INSTALLATION
5 Installationlocation............................................................................................................................55.1 Roomthermostat....................................................................................................55.2 Radioreceiver........................................................................................................5
6 Climapro2RFInstallation...................................................................................................................56.1 Dimensions.............................................................................................................56.2 Listofcontents.......................................................................................................6
7 Fixing.................................................................................................................................................67.1 Fixingtheroomthermostat.....................................................................................67.2 Installingtheradioreceiver.....................................................................................7
8 Electricalconnections.......................................................................................................................88.1 Mainboard..............................................................................................................88.2 Connectingtheradioreceiver................................................................................88.3 Pairing(recognition)...............................................................................................9
9 Commissioning................................................................................................................................109.1 Appliancesincludedintheinstallation..................................................................109.2 Roomthermostat..................................................................................................10
10 Specificsettings...............................................................................................................................1010.1 Mainsettings........................................................................................................1010.2 Accesstotheinstallermenu................................................................................. 1110.3 Descriptionoftheinstallermenu.......................................................................... 1110.4 Heatingfunction.................................................................................................... 1110.5 Domestichotwaterfunction.................................................................................1210.6 Coolingfunction....................................................................................................1310.7 Options.................................................................................................................1310.8 Radio....................................................................................................................15
11 Control/Commissioning..................................................................................................................15
12 Userinformation...............................................................................................................................15
TAbLe Of CONTeNTS
- 2 -
MAINTeNANCe
13 Faultdiagnosis.................................................................................................................................16
TeChNICAL DATA
14 Climapro2RF...................................................................................................................................17
15 Radioreceiver..................................................................................................................................17
TAbLe Of CONTeNTS
0020094586_01-08/10-Glow-worm- 3 -
INTRODUCTION
INTRODUCTION
1 Instructions guidance
1.1 Product documentation
TheinstructionsareanintegralpartoftheClimapro2RFandmustbehandedtotheuseroncompletionoftheinstallationinordertocomplywiththecurrentregulation.
• Carefullyreadthemanual,toenablesafeinstallation,useandservicing.Noliabilitycanbeacceptedintheeventofdamagefornotcomplyingwiththeguidanceinthisinstructionmanual.
1.2 Associated documents
- Userinstructions
1.3 explanation of symbols
e DANGER: Risk of electric shock.
ATTENTION: Risk of damage to the Climapro2 RF or to its vicinity.
IMPORTANT: Useful information.
2 Climapro2 Rf description
2.1 Regulation and statutory requirements
CE Mark
TheCEmarkindicatesthattheappliancesdescribedinthismanualareincompliancewiththefollowingdirectives:
- EuropeanDirectiveNum.2004-108oftheEuropeanParliamentandtheCouncilregardingelectromagneticcompatibility
- EuropeanDirectiveNum.2006-95oftheEuropeanParliamentandtheCouncilregardinglowvoltage
- Directiverelatingtotelecommunicationsequipment(CounciloftheEuropeanCommunitydirectiveR&TTE99/5/CEE).
2.2 Operational Diagram
Theroomthermostatcommunicateswithacontrolunitviaaradioreceiver.
EBUS
1
2
3
4
5
Legend1 Wall support for the Climapro2 Rf2 Radio receiver connected to the heating system 3 Testing heating system4 Room thermostat 5 batteries
3 Safety instructions and regulations
3.1 Safety regulations
AllworkinsideClimapro2RFmustbecarriedoutbyaqualifiedprofessionalorGlow-worm’sAfter-SalesService.
Climapro2RFmustonlybeinstalledbyaqualifiedandresponsibleprofessional,soastorespecttheapplicableregulationsandrules
Respectthebasicsafetyinstructions:
• Stoptheappliance.
• Cuttheelectricalpowertotheappliance.
• Whenworkontheapplianceiscompleted,performanoperationaltestandcheckforsafety.
0020094586_01-08/10-Glow-worm- 4 -
INTRODUCTION
3.2 Regulations
Duringtheinstallationandactivationoftheappliance,thedecrees,directives,technicalregulations,standardsandclauseshereaftermustbecompliedwithintheversionsthatarecurrentlyinforce.
4 Recycling
The recycling of the packaging must be carried out by the qualified professional who installed the room thermostat.
4.1 Climapro2 Rf
Mostoftheapplianceismadeofrecyclablematerials.
Thissymbolindicatesthatthisunitmustnotbedisposedofwithhouseholdwaste.Itshouldbeselectivelycollectedforenergyrecovery,reuseorrecycling.
• Taketheunittoanappropriatecollectionpointforprocessing,energyrecoveryandrecyclingofwaste.
By complying with this directive, you will contribute to the preservation of natural resources and the protection of human health.
4.2 Packaging
WerecommendthatyourecyclethepackagingofClimapro2RFinaresponsiblefashion.
• Sortthewasteinordertoseparatethoseelementswhichcanberecycled(cardboard,plastics)andthosewhichcannotberecycled.
• Disposeofthewasteinaccordancewithexistingregulations.
0020094586_01-08/10-Glow-worm- 5 -
INSTALLATION
INSTALLATION
5 Installation location
5.1 Room thermostat
• Explainthefollowingrequirementstotheuser.
Install the Climapro2 Rf:
- inaroomprotectedfromfrost,
- onaninteriorwallofthemainroominthehome,
- atapproximately1.50metresfromthefloor(accordingtotheregulationsinforce).
Do not install the Climapro2 Rf:
- Nearsourcesofheat,suchasradiators,chimneywalls,televisionsorsolarradiation,
- aboveacookerthatislikelytogiveoffsteamandgrease,
- oncoldwalls,
- betweenunitsorbehindcurtainsorotherobjectsthatmightdisturbtemperaturerecordingfortheambientairintheroom,
- inaroomthatisheavilyloadedwithdustorwheretheatmosphereiscorrosive,
- nearaircurrentsthatmaycomefromdoorsorwindows.
5.2 Radio receiver
Not all appliances have a location for holding the radio receiver. In this case, the radio receiver can be fixed to the wall.
Insidetheappliance:
• Installtheradioreceiverintheapplianceinthelocationprovided(seetheapplianceinstallationmanual).
Outsidetheappliance:
• Installtheradioreceiverneartheapplianceatapproximately1.8metresfromtheground.
• Keeptheradioreceiverawayfromallmetallicparts(cables,electricalcircuitboxes,metalwalls)soasnottodisturbtheradiotransmission.
1500
6 Climapro2 Rf Installation
Allofthemeasurementsinthischapterareexpressedinmm.
6.1 Dimensions
6.1.1 Room thermostat
62.5
34
6
173
0020094586_01-08/10-Glow-worm- 6 -
INSTALLATION
6.1.2 Wall support for the ambient temperature thermostat
66
27
58
6
6.1.3 Radio receiver
5820
171
6.2 List of contents
Thiskitisdeliveredwith:
- Climapro2RFprogrammableroomthermostat
- WallsupportfortheClimapro2RF
- Radioreceiver
- Packetcontaining2fixingscrewswithrawlplugs
- 4“AALR6"alkalinebatteries
- EBUScableforradioreceiver
7 fixing
7.1 fixing the room thermostat
• Determinethelocationinwhichtheinstallationistobeeffected.Seethe"Installationselection"chapter.
A
B
1
2
4
3
5
6
Legend1 Drilling2 fixing screw3 fixing holes4 Room thermostat support5 Plugs6 Room thermostat
• Positiontheroomthermostatsupport(4)onawall.
• Drill(A)thescrewholes(1)inaccordancewith2mountingholes(3)inthewallsupport(4).
• Inserttherawlplugs(5)intheholes(1).
• Secure(B)theroomthermostatsupport(4)withscrews(2).
• Slidetheroomthermostat(6)intoitssupport(4).
0020094586_01-08/10-Glow-worm- 7 -
INSTALLATION
7.2 Installing the radio receiver
Case n°1 - radio receiver on control box unit
1
2
Legend1 Control box unit2 Radio receiver
• Slidetheradioreceiverintothenotches.
1
2
Legend1 Radio receiver2 Location of radio receiver
Case n°2 - radio receiver in the control box unit
A
B
1
2
Legend1 Control box unit2 Radio receiver
The receiver should be installed outside the appliance if the appliance control box does not have a location for the radio receiver.
Case n°3 - radio receiver outside appliance
• Determinetheinstallationlocation.Seethe"Installationlocation"chapter.
A
B
5
4
3
2
1
Legend1 Radio receiver2 fixing screw3 fixing holes4 Plugs5 Drilling
• Positiontheradioreceiver(1)onawall.
• Drillthehole(5)forthefixingscrewinaccordancewiththefixinghole(3)ontheunitorusethestickypadifprovided.
• Inserttherawlplug(4)inthedrilledhole(5).
• Fixtheradioreceiverwiththefixingscrew(2).
• Respectthestandardsforelectricalinstallationsinforceforconnectingtheebuscablebetweentheradioreceiverandtheappliance.
0020094586_01-08/10-Glow-worm- 8 -
INSTALLATION
8 electrical connections
The electrical connection of the room thermostat must be made only by a qualified engineer.
The radio receiver must be connected to the eBUS connector.
8.1 Main board
1 2 3
30 mm max.
Legend1 Connector2 electrical wires3 Insulation
Whenconnectingelectricalcablestoaconnectorofthemainboard:
• Maintainamaximumdistanceof30mmbetweentheconnector(1)andtheinsulation(3).
8.2 Connecting the radio receiver
The location of the EBUS terminal block varies according to the heating system. It is always identified by having "BUS" written on it.
• UsetheEBUSconnectioncableprovided.
• CuttheEBUSconnectioncabletothelengthnecessaryforyourinstallation.
Case n°1 - radio receiver on the control box
• ConnecttheEBUScable,followingtheorderofoperationsfrom(A)to(F).
A
B
24V
C
1
2
3
Legend1 Access for 24 V connection2 Control box3 Pre-cut part of control box unit
• Open(A)theaccessforthe24Vconnection(1).
• Cut(B)thepre-cutpart(3)ofthecontrolboxunit(2).
• Remove(C)thepre-cutpartofthecontrolboxunit(2).
D
RT 24V T° extBUS
BUS24 V
F
E
1
2
3
6
5
4
Legend1 ebUS connecting cable2 Link the connection terminal block on the room thermostat3 ebUS terminal block for the main board4 Control box unit5 Radio receiver connector6 Pre-cut part of control box unit
• Donotremovethelinkfromtheterminalblockconnectingtheroomthermostattothemainboard.
• Pass(D)theEBUScable(1)throughthecablepassagecreatedbyremovingthepre-cutpart(6).
• Connect(EandF)theEBUScable(1)totheradioreceiver'sconnector(5)andtotheEBUSterminalblockonthemainboard(3).Thereisnopolaritythatmustberespected.
0020094586_01-08/10-Glow-worm- 9 -
INSTALLATION
Case n°2 - radio receiver in the control box unit
A
RT 24V T° extBUS
BUS24 V
B1
2
3
5
4
Legend1 ebUS connecting cable2 Link for the connection terminal block on the room thermostat3 ebUS terminal block for the main board4 Control box unit5 Radio receiver connector
• Donotremovethelinkfromtheterminalblock(2)connectingtheroomthermostattothemainboard.
• Connect(AandB)theEBUScable(1)totheradioreceiver'sconnector(5)andtotheEBUSterminalblockonthemainboard(3).Thereisnopolaritythatmustberespected.
Case n°3 - radio receiver outside the appliance
1
2
3
Legend1 ebus and 0V connection2 Cable strain relief3 Connector for the radio receiver
• Donotremovethelinkfromtheterminalblockforconnectingthemainboard’sroomthermostat.
• ConnecttheEBUScabletotheradioreceiverconnectorandtheEBUSand0Vconnectionintheelectricalcartridge.Polarityisnotimportant.
8.3 Pairing (recognition)
8.3.1 The room thermostat delivered with a radio receiver
Thepairingbetweentheroomthermostatanditsradioreceiverrequiresnoactiononyourpart.Itiscarriedoutinthefactory.
8.3.2 The radio receiver with wireless outdoor sensor
Pairingbetweentheexternaltemperatureprobeandtheradioreceiverispossible(seetheinstallationmanualfortheexternalprobe).
Theradioreceivercanbepairedwiththewirelessoutdoorsensor(seetheoutdoorsensorinstallationmanual).
0020094586_01-08/10-Glow-worm- 10 -
INSTALLATION
9 Commissioning
9.1 Appliances included in the installation
• Switchontheappliancesthatmakeuptheinstallation(seetheinstallationmanuals).
9.2 Room thermostat
B
A
C
1
3
2
4
5
Legend1 battery cover2 batteries3 Insulating strip4 battery compartment5 Room thermostat
• Removetheinsulatingstrip(3)locatedinthebatterycompartment,respectingtheorderofoperations(A)to(C).
• Performthepairingoftheroomthermostatbasedonyourinstallation(seeChapterpairing).
10 Specific settings
Accessingtheroomthermostatsinstallermenuallowsforsomeadjustmentstobemadetotheinstallation(roomthermostatandremotesensor)andtheroomthermostat’susermenu.
10.1 Main settings
function Title ActionHeating Maximum
roomtemperature
Chooseavaluebetween5°Cand30°C.(factorysetting:30°C).
Roomtemperaturecorrection
Chooseavaluebetween-5°Cand5°Cwithastepof0.5°C.(factorysetting:0°C).
Modulatingcontrol
Activate(ON)ordeactivate(OFF)(defaultsetting:OFF).
Hotwater On/Off Activate(ON)ordeactivate(OFF)(defaultsetting:ON).
Maximumtemperatureofdomestichotwater
Chooseavaluebetween38°Cand65°C.(factorysetting:60°C).
Program Enable(YES)ordisable(NO)(defaultsetting:ON).
Coolingfunction On/Off Activate(ON)ordeactivate(OFF)(defaultsetting:OFF).
Program Enable(YES)ordisable(NO)(defaultsetting:OFF).
Options(outdoorsensor)
Adjustmentpossibleonlyifanoutdoorsensorisconnected
Outsidetemperaturecorrection
Chooseavaluebetween-5°Cand5°Cwithastepof1°C.(factorysetting:0°C).
Choosingtheheatingprofile
Chooseavaluebetween0.2and4.(factorysetting:2).Seetheinstructionsfortheoutdoorsensorconnectedtotheappliancetocarryoutthisadjustment.Note:thesettingsfortheoutdoorsensormadeontheappliancewillnolongerbeactive.
0020094586_01-08/10-Glow-worm- 11 -
INSTALLATION
10.2 Access to the installer menu
• Pressbutton for7seconds.
• Entertheinstallercode96.
10.3 Description of the installer menu
Menu browsing
Usethebuttons:
Selectwiththebutton:
Selectwiththebutton:- toreturntotheprofessionalmenuscreen,
- for3secondstoreturntotheuser'smainscreen.
Showing, enabling and disabling of functions is reflected in the user menu.
10.4 heating function
Menu This menu lets you:Setthemaximumadjustableroomtemperature.
Correctthemeasurementoftheroomtemperature.
Activateordeactivatethemodulatingcontrolforthehotwatertemperature.
(*)automaticadjustmentoftheheatingwatertemperature
10.4.1 To set the maximum room temperature
Thisfunctionletsyouadjustthemaximumroomtemperaturethatcanbesetbytheuser(valueadjustablebetween5and30°C-factorysetting:30°C).
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>heating>maximum room TO.
• Increaseordecreasewiththebuttons todisplaytheinitialcoolingtemperatureandpressthebutton .
10.4.2 Correcting the room temperature
Thisfunctionletsyourectifythetemperaturemeasuredbytheambienttemperaturethermostat(by+/-5°Cwithastepof0.5°C-(factorysetting:0).
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>heating>room temperature correction
• Increaseorreducewiththe buttonstodisplaythedesiredcorrectionandvalidatewithbutton .
10.4.3 Activating or deactivating the modulating control
Thisfunctionletsyouadapttheflowtemperatureintheheatingsystem.
0020094586_01-08/10-Glow-worm- 12 -
INSTALLATION
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>heating>modulating control
• Press tohighlightyourchoice(OnorOff)andpressthebutton toconfirm.
10.5 Domestic hot water function
Menu This menu lets you:Showorhidethedomestichotwaterfunctionintheendusermenu
Setthemaximumdomestichotwatertemperature.
Enableordisablethedomestichotwaterreheatingprogramintheendusermenu
10.5.1 The hot water function
Thisfunctionletsyouactivateordeactivatethehotwatermenufortheuser.
If the function is deactivated, the domestic hot water settings are adjusted via the appliance.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen> hot water>on/off
• Press tohighlightyourchoice(activateordeactivate)andpressthebutton toconfirm.
10.5.2 Adjust the maximum domestic hot water temperature
Thisfunctionletsyouadjustthemaximumhotwatertemperaturethatcanbesetbytheuser(valueadjustablebetween38and65°C-factorysetting:60°C).
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>hot water>maximum temperature
• Increaseorreducewiththe buttonstodisplaythedesiredwatertemperatureandvalidatewithbutton .
10.5.3 To enable or disable the domestic hot water heating program
The hot water function must be activated before it can be programmed. Depending on the appliance, deactivation cuts off the hot water heating as well as the production of hot water (see the appliances installation manual).
Thisfunctionmakesitpossibletoallowtheusertoprogramdomestichotwaterreheating.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>hot water>enable program
• Press tohighlightyourchoice(enableordisable)andpressthebutton toconfirm.
0020094586_01-08/10-Glow-worm- 13 -
INSTALLATION
10.6 Cooling function
Menu This menu lets you:
Activateordeactivatethecoolingfunctionintheendusermenu.
Enableordisablethecoolingprogramintheendusermenu.
10.6.1 Activate or deactivate the cooling function
Thisfunctionallowstheusertoactivateordeactivatethecoolingmenu.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>cooling >on/off
• Press tohighlightyourchoice(activateordeactivate)andpressthebutton toconfirm.
10.6.2 enable or disable the cooling program
The cooling function must be activated before it can be programmed.
Thisfunctionmakesitpossibletoallowtheusertoprogramcooling.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>cooling> enable program
• Press tohighlightyourchoice(enableordisable)andpressthebutton toconfirm.
10.7 Options
Menu This menu lets you:
Configurethewirelessoutdoorsensor:
- forcorrectingthemeasuredoutsidetemperature,
- forchoosingtheheatingcurve(seetheinstructionsforthewirelessoutdoorsensor).
Adjustthedateandtime
Choosethelanguage
Enterthetelephonenumberthatwillbedisplayedinafter-salesservicemessages.
Displayinformation:zone,typeandsoftwareversionfortheroomthermostat
10.7.1 Outdoor sensor settings
Correcting the outside temperature
Thisfunctionletsyourectifythetemperaturemeasuredbytheroomthermostat(by+/-5°Cwithastepof1°C-factorysetting:0).
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>settings >outdoor sensor settings>outside TO correction
• Increaseorreducewiththe buttonstodisplaythedesiredcorrectionandvalidatewithbutton .
Choosing the heating curve (gradient)
Thisfunctionletsyouchoosetheheatingprofile(valueadjustablebetween0.2and4-factorysetting:1.6).
• Seetheinstallationmanualfortheoutdoorsensor.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen> settings>outdoor sensor settings >selectheating curve
0020094586_01-08/10-Glow-worm- 14 -
INSTALLATION
• Usingthe buttons,selectthedesiredheatingprofileandvalidatewiththe button.
10.7.2 Setting the current date
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>settings>date
• Setthedisplayformatofthecurrentdatebypressing andpressing toconfirm.Thereisachoicebetweenthefactorysettingday/month/yearandyear/month/day.
• Setthecurrentdatebypressing andpressingthebutton toconfirm.
10.7.3 Setting the current time
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>settings>language
• Setthetimebypressing andpressingthebuttontoconfirm.
10.7.4 Choose the language for the menus
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>settings>language
Todisplaytheadditionallanguages:
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>other
• Choosethelanguagewiththebutton andpressthebutton toconfirm.
10.7.5 Telephone After-Sales Service
Thisfunctionletsyouspecifythetelephonenumberthatwillbedisplayedinafter-salesservicemessagesfromtheroomthermostat.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>settings>telephone
• Displaythedesirednumberwiththe buttonsandvalidatewiththe button.
• Validatethedashesfollowingthetelephonenumberwiththebutton.
10.7.6 General information on Climapro2 Rf
Thisfeatureallowsyoutodisplaythefollowinginformation:area,softwaretypeandversion.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>settings>about
0020094586_01-08/10-Glow-worm- 15 -
INSTALLATION
10.8 Radio
Menu This menu lets you:
Establishtheconnectionbetweentheradioreceiverandtheroomthermostat.
Testthequalityoftheradiosignal(thermostatandwirelessoutdoorsensor).
10.8.1 Pairing
Thisfunctionletsyouperformthepairingbetweenthethermostatandtheradioreceiver.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>Rf>pairing
10.8.2 Test
Thisfunctionletsyoutestthequalityofthesignalbetweentheroomthermostatandtheradioreceiver.
Inthecasewhereawirelessoutdoorsensorisincludedintheheatingsystem,theroomthermostatwillalsoindicatethequalityofthesignalbetweentheoutdoorsensorandtheradioreceiver.
Wait about fifteen minutes after activating the thermostat and the outdoor sensor before testing.
Signal Quality CommentExcellent
NormalfunctioningAverage
Poor Operatinglimit*
Null Inoperative*
(*) Check the room thermostat’s batteries (see the instructions). If the signal quality does not improve. Change the location of the appliances, reducing distances and removing obstacles.
• Fromtheinstallermenu(seeaccesstotheinstallermenu)>selectonthescreen>Rf>test
11 Control / Commissioning
Afterinstallingtheroomthermostat:
• Turnontheapplianceaccordingtotheoperatinginstructionsandcheckforcorrectoperation.
12 User information
Attheendoftheinstallation:
- explaintheoperationoftheapplianceanditssafetydevicestotheuser,ifnecessaryprovideademonstrationandansweranyquestions;
- givetheuseralltherequireddocumentation,
- fillinthedocumentswherenecessary;
- advisetheuseroftheprecautionsnecessarytopreventdamagetothesystem,applianceandthebuilding;
- remindtheusertoservicetheapplianceannually.
0020094586_01-08/10-Glow-worm- 16 -
MAINTENANCE
MAINTeNANCe
13 fault diagnosis
In case the signal is lost between the room thermostat and the radio receiver (e.g. : batteries exhausted), the heating system uses its own functioning settings.
Faults described in this chapter should be carried out by a qualified engineer and if needed by the After Sales Service.
Youwillfindalistofcertainerrorcodesintheusermanual.
5
4
3
2
1
Legend1 Radio receiver2 Cover for radio receiver3 Red LeD4 Radio receiver circuit board5 Green LeD
Intheeventofaproblem:
• Checktheerrormessagesintheroomtemperaturethermostat'sdisplayzone
• Removethecover(2)fromtheradioreceiver(1)toseethe2LEDs.
• Checkthestateofthe2LEDs(green(5)andred(3)locatedontheelectronicboard(4)intheradioreceiver.
Radio receiver
Cause Solution
GreenLEDoff
RedLEDoff
-Failureofelectricalsupply-DefectiveEBUSconnectioncable
•Ensurethatthereisnointerruptiontotheelectricitysupplyandthattheapplianceisproperlyconnectedandturnedon.•Checktheelectricalconnectionbetweenthereceiverandtheappliance.
RedLEDswitchedon
-Appliancefault-Radiosignaltransmissionerror-EBUScommunicationserror-Defectiveradiotransmitterorreceiver-EBUSconnectingcabledefective
•Checkthat:-Theappliancesfunctioningstatusiscorrect-Theroomthermostatbatteriesareproperlyinstalledintheircompartment-Thebatterypolarityisnotreversed-Thebatteriesarenotexhausted.Ifso,replacewithnewbatteries.•Checktheelectricalconnectionbetweenthereceiverandtheappliance.•Checktheradiocommunicationbetweenthethermostatandthereceiver.
0020094586_01-08/10-Glow-worm- 17 -
TECHNICALDATA
TeChNICAL DATA
14 Climapro2 Rf
Description Unit Climapro2 Rf
Transmission/receptionfrequency
MHz 868
Transmission/receptionfrequencybetweentheoutdoorsensorandtheroomthermostat
min 15
Transmission/receptionfrequencybetweentheapplianceandtheroomthermostat
min 10
Averageunobstructedworkingrange(*)
m 100
Averagerangewithinthehome(*)
m 25
(*)CanvaryaccordingtoinstallationconditionsandelectromagneticenvironmentRoom thermostatRoomtemperatureauthorizedintheroomwherethecontrolisinstalled
°C 50
Maximumauthorisedtemperatureofdomesticwater
°C 65
Dimensions:Height mm 173Width mm 62,5Depth mm 34Supply:4“AALR6"alkalinebatteries
V 4x1.5
Batterylife(**) month 18(**)UndernormalconditionsofuseRoom thermostat supportDimensions:Height mm 58Width mm 66Depth mm 27Spacingbetweentheroomthermostat(insupport)andthewall
mm 6
15 Radio receiver
Description Unit Radio receiverTransmission/receptionfrequency
MHz 868
Transmission/receptionfrequencybetweentheoutdoorsensorandtheroomthermostat
min 15
Transmission/receptionfrequencybetweentheapplianceandtheroomthermostat
min 10
Averageunobstructedworkingrange(*)
m 100
Averagerangewithinthehome(*)
m 25
(*)CanvaryaccordingtoinstallationconditionsandelectromagneticenvironmentRadio receiverDimensions:Height mm 20Width mm 171Depth mm 58Power-supplyvoltageEBUS V 24VElectricalconnectioncablesection
mm² 2x0.75
Max.lengthofelectricconnectioncables
m 300
0020094586_01-08/10
Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.