18
Certus Metrology Consultation & Training Services Temperature Humidity Pressure Electrical

Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

CertusMetrology

Consultation & Training Services

Temperature

Humidity

Pressure

Electrical

Page 2: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

Introduction ..................................................................................................................................................................................................................................2

About the Director ..................................................................................................................................................................................................3

Consultation and Training Service ......................................................................................................................4

Temperature Calibration Service ..............................................................................................................................6

Humidity Calibration Service ..........................................................................................................................................10

Pressure Calibration Service ...............................................................................................................................................12

Electrical Calibration Service ............................................................................................................................................14

CONTENTS

Page 3: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

2 Certus Metrology

You CAn CounT on CErTuS for:ConSISTEnCY – We address every variable of our measurement process to assure consistency of calibration results, which leads to accurate results in your processes, products and services.

• Environmental Controls – CErtus laboratories environmental conditions are strictly monitor and control.

• Finest Equipment – for each measurement quantity, CErtus possesses the finest calibration equipment available.

• Highly skilled Metrologists and technicians – CErtus has a highly trained staff of metrologists and technicians capable of making precise measurements and monitoring calibration processes.

• Measurement system – CErtus’s measurement system is constantly reviewed. our multiple reference standards are directly traceable to national and International standard.

ConfIDEnCE – CErtus assures its consistency through independent verification because CERTUS is Certain.

• Accreditation – CErtus’s Calibration System comply to ISo/IEC 17025 standards.

• Documented Procedures – Procedures are documented for every step of the calibration process.

• Inter laboratory comparison / proficiency testing – CErtus participation in proficiency testing enables the laboratory to assess and demonstrate the reliability of the resultant measurement data by comparison with results from other participating laboratories.

CoMMITMEnT – CErtus committed to provide an extra miles to our customers.

• Attitude - To being polite, patient, and thorough.• respond - We commit to timely and comprehensive responses.• solve - We commit to helping you resolve technical issues to

your satisfaction.• Feedback - We listening to your feedback.

CErTuS CalIbraTION SErvICES

Page 4: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 3

abOuT ThE FOuNdEr & dIrECTOr

TJHANG HENDRI - is a founder and Director of PT. Certus Metrology Indonesia.

He holds a Bachelor of Engineering (Mechanical Engineering) Degree from Trisakti university, Jakarta and Master of Science (Mechanical Engineering) Degree from nanyang Technological university, Singapore.

using his knowledge, expertise and skills, he is serving as a Technical Assessor for Accredited Laboratory in area of calibration and measurement in Singapore, Member of Metrology Society of Australia and Member of Institute of Physic, London.

He has more than 10 years of experience in the calibration and measurement and has received training in temperature, pressure, humidity and ISo 17025 related courses in Singapore and united Kingdom.

Previously, joined a private calibration laboratory in Singapore specialize in temperature, pressure and humidity as a Business and Development Manager cum Head of Laboratory for years. Throughout his career as Head of Laboratory in Singapore, he has numerous contributions to the laboratory by developing the technical capability on their existing fields in additions the new fields of electrical and airflow calibration. And have design a wind tunnel for airflow calibration facility and developing Microsoft® Excel based calculation software for infra red thermometer calibration.

His passion to the metrology has given him a wide opportunity by opening his own laboratory, CErtus MEtrology InDonEsIA to pursue further innovation and give the customer assurance quality of services.

Page 5: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

4 Certus Metrology

Consultation & Training Services

TRAINING & CoNSUlTATIoN SERvICES – Our qualified and experienced trainers had put together of experience and expertise to help industries grow through our training program and consultation.

Page 6: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 5

CErtus’s training syllabus is built around our core business which is Temperature, Humidity, Pressure and Electrical.our qualified and experienced trainers had put together more than 10 years of experience and expertise will benefit the industries to grow through our training session and consultation.our training could also be tailored to your location, your specific requirement and at your convenience. fACILITY AnD EquIPMEnT Environmental monitor and control Temperature, Humidity, Pressure and Electrical laboratory fully equips with the state-of-the-art reference standards.Training room with projector and screen. ProCESSESCErtus can offer standard and custom training program in area of our core business and expertise. In additions, CErtus also extend its service to a measurement solution, setting up a new calibration laboratory, reference standards commissioning or technical assessment for newly set up calibration laboratory.

TrAInIng AnD ConSuLTATIon SErvICES InCLuDE:• ResistanceThermometry• FixedPoint• ThermocoupleThermometry• ResistanceThermometry• RadiationThermometry• LiquidInGlassThermometry• Temperatureand/orHumidityEnclosure• Humiditymeasurementandcalibration• Pressuremeasurementandcalibration• Consultationonsettingupcalibrationlaboratory• Consultationonmeasurementsolution• Commissioning• Technicalassessmentfornewlysetupcalibrationlaboratory• Couldn’tfindwhatyoulookingforfromabovelist,

please consult with us for your specific requirement

Page 7: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

6 Certus Metrology

Temperature

TEMpERATURE – Temperature Calibrations from -35° C to 1200° C , Comparison calibrations or selected fixed points for all of your resistance temperature measuring devices including Semi Standards pRT’s, RTD’s, thermistors, digital readouts, calibrators, liquid-in-glass thermometers, radiation thermometer and thermocouples.

Page 8: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 7

CErtus’s Temperature Calibration Laboratory utilizes the most advanced equipment and training to provide the lowest temperature measurement uncertainties available in the market place. CErtus’s Temperature Laboratory is ISo/IEC 17025 compliant for temperature calibrations. CErtus offers a complete range of temperature calibration services from -35°C to 1200°C for Semi Standard PRT’s, RTD’s, Thermistors, Thermocouples, Digitalreadouts, radiation Thermometer and Liquid-in-glass Thermometers.

fACILITY AnD EnvIronMEnTCErtus’s Temperature Calibration Laboratories meet strict ISo/IEC 17025 guidelines. Environmental conditions in the Laboratory are strictly monitored and controlled.

EquIPMEnTCErtus’s Temperature Calibration Laboratory is outfitted with the latest state-of-the-art equipment for fixed point and comparison temperature calibrations. Equipment includes an High Precision Thermometer Indicator, a variety of cells covering two temperature fixed points (ga and H2o), high precision standard resistors, blackbody source and calibration baths (Alcohol, oil, and Block).

ProCESSESCErtus can tailor a calibration for your temperature-measuring device from primary fixed point calibrations for calibrating in-house temperature standards and high precision temperature devices to secondary comparison calibrations for less accurate temperature measuring devices. All temperature standards are traceable to the national and International.

Page 9: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

8 Certus Metrology

TEMPErATurE CALIBrATIon SErvICES InCLuDE:

•Temperature calibration services – from -35°C to1200°C for Semi StandardPRT’s, RTD’s,Thermistors, Thermocouples, Digital readouts, Calibrators radiation Thermometer and Liquid in glass Thermometers.

• Calibration Method – fixed-Point and Comparison

• ISO/IEC17025compliantlaboratory

• Fastturnaroundtime

CErtus offers a variety of standard calibration services. We can also customize a calibration to meet your requirements. The various services available from CErtus include:

Calibration Certificate for Comparison Temperature Calibrations - A detailed, multi-page temperature certificate designed to meet all regulatory and audit requirements.

Calibration Certificate for Fixed-Point Temperature Calibrations – A detailed, multi-page temperature certificate that contains calibration data for comparisons to fixed point cell(s). Coefficient calculation for PrT’s, Thermistor and Thermocouple.

Page 10: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 9

TEMPEraTurE raNGESdevice Calibration Service Temperature

SPRT, PRT, Precision Thermistor

Fixed Point Calibration 0.01°C (Water Triple Point)

29.7646°C (Gallium Melt Point)

Semi standard PRT, PRT Comparison to Reference PRT -35°C to 500°C

Thermistor Comparison to Reference PRT -35°C to 250°C

Thermocouple Comparison to Reference PRT or Type S Thermocouple

-35°C to 1200°C

Liquid-in-Glass Comparison to Reference PRT -35°C to 250°C

Digital/Analogue Readoutsand calibrator

Resistance and mV -270 to 1768°C

Page 11: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

10 Certus Metrology

Humidity

HUMIDITy – Humidity Calibrations from 10% to 95% – Calibrations on a wide variety of humidity measurement devices including chart recorders, data loggers, hygrometers, thermo-hygrographs, sensors, transmitters and dew point hygrometers.

Page 12: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 11

CErtus offers standard and custom calibration services for a wide variety of humidity measuring devices including chart recorders/data loggers, sensors, thermo-hygrographs, transmitters and hygrometers. CErtus also calibrates dew point hygrometers.

fACILITY AnD EnvIronMEnTThe Humidity Calibration Laboratory is ISo/IEC 17025 compliant. Environmental conditions in the Laboratory are strictly monitored and controlled.

EquIPMEnTCErtus’s Humidity Calibration Laboratory utilizes the “two-pressure” and “two-temperature” humidity generation process developed and proven by nIST. This design produces high precision humidity determinations ideal for instrument calibration and evaluation. CErtus is proudly used our very own design of “two temperature” humidity generator for our humidity calibration. Laboratory capabilities are 10% to 95% relative Humidity. Temperature range covered is 5°C to 70°C.

ProCESSESCErtus offers standard and custom humidity calibration procedures. CErtus’s traceable Humidity Calibration Certificate is a detailed, multi-page document designed to meet all regulatory and audit requirements.

HuMIDITY CALIBrATIon SErvICES InCLuDE:• Calibration capabilities: 10% to 95% Relative Humidity at 5°C to 70°C,

Dew Point range -30°C to 70°C

• Types of instruments serviced include: Chart recorders/Data loggers,Thermohygroraphs, Sensors, Hygrometers, Transmitters & Dew point hygrometers

• ISO/IEC17025compliantlaboratory

• Fastturnaroundtime

Page 13: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

12 Certus Metrology

Electrical

ElECTRICAl – Electrical calibrations include DC voltage, DC Current, AC voltage, AC Current, Resistance, and Capacitance for calibrator and indicator.

Page 14: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 13

All electrical calibrations are ISo/IEC 17025 compliant and include DC voltage, DC Current, AC voltage, AC Current, resistance and Capacitance. CErtus can calibrate most equipment that generate and measure for the above disciplines as well as most multimeters up to 5.5 digits. ranges and uncertainties are found in the table below.

fACILITY AnD EnvIronMEnT CErtus’s Electrical Calibration Laboratory meets ISo 17025 guidelines. Environmental conditions in the laboratory are strictly monitored and controlled.

EquIPMEnTCErtus’s Electrical Calibration Laboratory is outfitted with the latest state-of-theart equipment. Equipment includes multi function calibrators for electrical measurements calibration, 7.5 digits multimeter and Standard resistors.

ProCESSESCErtus’s can tailor a calibration for your Electrical devices if our standard service does not meet your needs.

CErTuS Calibration Certificates for Electrical, Calibrations - A detailed multi-page ISo/IEC 17025 compliant calibration certificate traceable to International standards that contains the following data: “as found” readings, standards used, uncertainty of measurements, low/high limit of device being calibrated, and environmental conditions.

raNGES aNd uNCErTaINTIESMeasurement discipline range uncertainty

DC Voltage 0 – 1025 V 25 ppm

DC Current 0 – 30 A 50 ppm

AC Voltage 0 V – 1020 V Frequency range 10 Hz – 500 kHz 0.035%

AC Current 0 A – 30 A Frequency range 10 Hz – 10 kHz 0.06%

Resistance DC 0 – 1 GΩ 40 ppm

Capacitance 1 nF – 10 μF 0.25%

Frequency 1 Hz – 10 MHz 20 ppm

Page 15: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

14 Certus Metrology

Pressure

pRESSURE – pressure Calibrations from -1 to 1000 bar with accuracy as low as 0.015% of reading – Types of instruments serviced by CErtus include gages, transmitters, transducers, calibrators, monitors and dead weight testers in gauge, vacuum and differential mode. Four standard levels of service, as well as custom services are available.

Page 16: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

www.certus-met.com 15

CErtus’s Pressure Calibration Laboratory utilizes the latest calibration equipment with reference standards traceable to the national and International.

fACILITY, EnvIronMEnT AnD EquIPMEnT Environmental conditions in the Laboratory are strictly monitored and controlled. All pressure calibration equipment used in CErtus’s Pressure Calibration Laboratories is state-of-the-art with the highest precision possible.Calibration equipment includes a two Dead weight tester as a primary pressure standard and sets of class f1 trims mass.

ProCESSESCErtus can offers standard and custom calibration services for a wide variety of pressure measuring devices. CErtus’s Calibration Certificate is a detailed, multi-page document designed to meet all regulatory and audit requirements.

Page 17: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

16 Certus Metrology

STaNdard PrESSurE CalIbraTION SErvICES Deadweight Testers Level 1 Level 2 Level 3

Device Accuracy (% of Reading /FS)

< ±0.05% ≥ ±0.05% < ±0.1% ≥ ±0.1%

ISO 17025 compliant • • • •

National/International Traceable • • • •

turnaround time** Less than 2 weeks 3 to 5 working days 3 to 5 working days 3 to 5 working days

Expedited service available • • • •

“As found” and “as left” data • • • •

Adjustments** & Cleaning as required • • • •

**Term and conditions apply

PrESSurE CALIBrATIon SErvICES InCLuDE:• National/Internationaltraceablecalibrations

• LaboratoryisISO/IEC17025compliant.

• Capabilities:-1barto1000barwithaccuracyaslowas0.015%ofreading.

• Types of instruments serviced include: Gages, Transducers, Calibrators,Monitors, Pressure Controllers and Deadweight Testers in gauge, vacuum and differential mode.

• Detailedcertificateprovidedwithyourpressuremeasurementdevices

• Fastturnaroundtime

Pressure Calibration Certificate – A detailed, multi-page pressure certificate designed to meet all your all regulatory and audit requirements.Certificate includes “as found” and “as left” data for: reference Pressure, Device under Test and Accuracy found. In addition, deadweight tester certificates include cross floating calibration data for the deadweights.

Page 18: Certus Metrologycertus-met.com/download/Certus Company Brochure LR.pdfDC Voltage 0 – 1025 V 25 ppm DC Current 0 – 30 A 50 ppm AC Voltage 0 V – 1020 V Frequency range 10 Hz –

PT. Certus Metrology IndonesiaKomplek ITC Duta Mas Fatmawati Blok D2 no. 8

Jl. RS Fatmawati No. 39, Jakarta Selatan - Indonesia Tel: (62) 21 7396965, 7396967 • Fax: (62) 21 7246634

www.certus-met.com

CertusMetrology

© d

esig

ned

by Le

vive

L (le

vive

l@ya

hoo.

com

.sg)