ertified Data Centre Professional | CDCP Lesson 1 - The Mission Critical Site Data centre's; the foundation of any organization Downtime and its consequences The data centre and the value at stake

Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

  • Upload
    others

  • View
    29

  • Download
    4

Embed Size (px)

Citation preview

Page 1: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

CertifiedDataCentreProfessional | CDCP

Lesson1-TheMissionCriticalSite

Datacentre's;thefoundationofanyorganizationDowntimeanditsconsequencesThedatacentreandthevalueatstake

Page 2: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

ThecomplexityofdatacentresRiskfactorsfordatacentresMaincausesofdowntimePredominantcausesfordatacentrefailuresThemoralofthestory

Lesson2-DataCentreStandards

DataCentrestandardsANSI/TIA-942redundancylevelsStandardsusedfordatacentre'sInternationalversusnationalstandards

Lesson3-TheDataCentrelocation,BuildingandConstruction

SiteselectioncriteriaSiteselectioncriteria:LocationevaluationSiteselectioncriteria:Location(cont.)

Page 3: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Siteselectioncriteria:BuildingTheDataCentreandsupportingfacilitiesHoldingareaStagingareaComputer/ServerroomMediastorageareaUPSroomBatteryroomServicecorridorStandbygeneratorsetroom/areaMeet-MeIEntranceroomSecurityroomNOC(NetworkOperationsControl)/CommandcentreClassicmistakes

Lesson4-RaisedAccessFloorandSuspendedCeiling

RaisedfloorLoadingfactorsRaisedfloor:Standards(Metric)Raisedfloor:Standards{lmperial)Raisedfloor(Metric)

Page 4: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Raisedfloor{lmperial)Raisedfloor;GeneralguidelinesGroundingofraisedfloorGroundingofraisedfloorCuttingholesinaraisedfloortileRampsOtherconsiderationsSuspendedceiling

lesson5-light

LightdefinitionandunitofmeasureStandardslightfixturesandplacementEmergencylightTypeofemergencylights

lesson6-PowerInfrastructure

PowersupplyqualityEverincreasingpowerrequirements

Page 5: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

NewtechnologiesonthehorizonFromsourcetodestinationInthebuilding,redundancyoptionsFunctionoftheATSpanelInthebuilding,redundancyoptionsInthebuilding,redundancyoptions(cont.}FunctionoftheSTSpanetInthebuilding,redundancyoptions(cont.)ThreephasepowercablingConversionfromthreephasetosinglephaseThreephase/SinglephaseusageProperpowercableroutingRackpowerdistribution-dualfeedDualpowersourcesOption1:LoveavailabilityOption2:SlightlybetteravailabilityOption3:ImprovedavailabilityOption4:High-availability(exampleA)Option4:High_-availability(exampleB)CommontechniquesforpoweravailabilityPowerdistributionwithintheDataCentreCablingorbusbartrunkingGroundinginthedatacentreCommonModeNoise(CMN)GroundingCommonModeNoise(CMN)

Page 6: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Bondingofneural&groundDatacentrepowerdistribution-GoodDatacentrepowerdistribution-BestIsolationtransformersDistributionboardsFormfactorsFormfactorexamplesIP(IngressProtection)protectiongradesIPprotectiongrades-firstnumberIPprotectiongrades-secondnumberPowerQualityPowerquality;guidelinesCBEMA/ITl{C)curvesPowerquality;harmonicsPower;realversusapparentlabelpowerversusactualpowerconsumptionSizinguppowerusageforthedatacentre(sqft)Sizinguppowerusageforthedatacentre(sqmtr)DataCentreincomingpowersizingGeneratorsetsUPStechnologyStaticUPSsystemsDynamicUPSsystemsStaticUPStechnologiesOfflineIStandbyUPS(VFD)

Page 7: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Offline/StandbyUPS(VFD}lineinteractiveUPS{Vl)Trueonlinedoubleconversion(VFI)QuickcomparisontableEnergyfriendlyoptionsUPSinnormalmodeUPSrunningonbatteriesUPSrunningonstaticbypassUPSrunningonmaintenancebypassIncreasingavailabilityofUPSinstallationBypassIHot-standbyparallelParallelredundantUPSIsolatedparallelredundantDynamicUPS;normalutilitymodeDynamicUPS;changetodieselmodeDynamicUPS;continuousdieselsupplymodeDynamicUPS;returntonormalmodeMainbatterytechnologiesforUPSFloodedcellsSlA/VRLANickelcadmiumBatterytestingandtestersThermographicscanning

Page 8: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

lesson7-ElectroMagneticFields

ElectromagneticspectrumElectric&magneticfieldsWhatcausesEMF?WhatthevendorssayEMF-effectsonintegratedcircuitsMagneticfieldsandnetworkcablingBiologicaleffectsofEMFStandardsEMP/HEMPEMF-bestpracticesduringdesignphaseDesign/installationanalysisEMFprotectionbyusingshieldingShieldingperformance

lesson8-EquipmentRacks

TypeofracksandstandardsWidthofracksWidthofracksWhichracktouse

Page 9: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

GlassdoorracksPerforated/GrateddoorracksMeshdoorracksBaseoftherackColoroftherackSecurityPowerRails/StripsPowerRails/StripsAdditionalconsiderations

Lesson9-CoolingInfrastructure

DatacentrecoolingRecommendedTemperature/HumidityRecommendedhumidityCoolinganditsimpactonReliabilityFuturecoolingCoolingcapacitySensible/LatentHeatCoolingSystemsDifferencebetweenComfortandPrecisionCoolingBasicprincipleofAirConditioningAir-Conditioning:Air-cooled,Self-ContainedAir-Conditioning:Air-cooled,SplitSystem(DX)Air-Conditioning:Fluid-Cooled(Glycol)

Page 10: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Air-Conditioning:WaterCooledAir-Conditioning:ChilledWaterTopFloworDownFlow'Raisedfloor'versus'noraisedfloor'CoolingConcepts;RaisedFloorRaisedFloorPrincipleofRaisedFloorDesign'ClassRoom'setupHot-andCold-AisleSetupHot-andCold-AisleSetupwithSuspendedCeilingAirConditioningPositioningPlacementofequipmentinrackAvoidLeakageandShortCircuitAirTemperatureandAirVolumeCFM/CMHPerforatedtileandequipmentplacementComputerRoomCoolingConcepts;Non-RaisedFloorNon-RaisedfloorsolutionsNon-Raisedfloorcoolingoptions;In-RowNon-Raisedfloorcoolingoptions;OverheadDuctNon-Raisedfloorcoolingoptions;OverheadDuctCoolingConcepts;SupplementalCoolingHighDensityCooling:AirDuctFanHighDensityCooling:HotAirFansHighDensityCooling:OverheadSupplementAir

Page 11: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

In-RowCoolingReardoorheatexchangerHighDensityCooling;Self-ContainedRacksSelf-ContainedRacksCoolingConcepts;ContainmentHotAisleorColdAisleContainment?ContainmentpotentiallyimpactsFireSuppressionPartialcontainmentBreakContainmentwithRetractableRoofHypoxic-AirFirePreventionFireSuppressionwithintheContainedAreaHotAisleorColdAisleContainment?ColdAisleContainmentHotAisleContainment

Lesson10-WaterSupply

TheimportanceofwaterinaDataCentreBackupwatersupply;WaterstoragetanksBackupwatersupply;'Well'waterBackupwatersupply;Wellwater-risksBackupwatersupply;Retentionpond

Page 12: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Lesson11-DesigningaScalableNetworkInfrastructure

TheimportanceofastructuredcablingsystemPlanningconsiderationsStructuredversuson-demandsystemCablingcharacteristics-CoppercablesCoppercablesCoppertermination/patchpanelsFibercablesCablingcharacteristics-FibercablesSinglemodeversusmultimodeCommonfibersupportlengthsversusspeedFiberterminations/patchpanelsTIA942networkcablelogicalarchitectureTIA942networkcable/RatinglevelsillustrationCablingrecommendationbyTIA-942A(2012)TestingandverifyingstructuredcablingStorageAreaNetworks(SAN)NetworkredundancyBuildingtobuildingconnectivity-Telco

Page 13: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

Buildingtobuildingconnectivity-HardwireBuildingtobuildingconnectivity-CanopyBuildingtobuildingconnectivity-FSONetworkmonitoringNetworkmonitoringsystemrequiredcapabilities

Lesson12-FireProtectionandSafety

FireprotectionandsafetyRequirementsforDataCentrefiresuppressionStandardsDetectionsystemsFiresuppressionsystemBestpracticesformainfiresuppressionHandheldextinguishersSignageandsafetyRegulatoryrequirements/Bestpractice

Lesson13-DataCentreMonitoring

Page 14: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

ThechallengeDataCentremonitoringrequirementsEMSversusBMSRemotemonitoringsolutionWhattomonitor?WaterleakdetectionAlarmpanelsbasedonzonesAlarmpanelsbasedonzoneand/ordistanceNotificationIsyourenvironmentmonitored?

Lesson14-OperationalSecurityandSafety

ThebigquestionDataCentresecurityPhysicalsecurityDoorcontrolsSecuritywithintheDataCentreInfrastructuresecurityOrganizational/processsecuritySecurityrequirescontinuousimprovementOperationalsafetyFiresafetyEssentialsignage

Lesson15-Labeling

Page 15: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

RacknumberingandlabelingLabelingofUPS,lsoTrans,PDU's,breakersLabelingofnetworkcabling

Lesson16-DocumentationDocumentation

ProceduresanddisciplineDocumentmanagement429

Lesson17-CleaningPractices

CleaningofDataCentre'sDataCentrevacuumcleanersCleaningtheraisedfloorCleaningofequipmentCleaningabovethesuspendedceilingGeneralcomputerroomrules

lesson18-MTBF/MTTF/MTTRObjectives

MTBFIMTIR/MTTFdefinitionsMTIF-MTTR-MTBRRelationReliabilityversusavailability

Page 16: Certified Data Centre Professional CDCP · The complexity of data centres Risk factors for data centres Main causes of downtime Predominant causes for data centre failures The moral

MTBF,anyvalue?

lesson19-SLA,OLAandMaintenanceContracts

ObjectivesSLAandOLAMaintenancecontractsEvaluatingtheserviceproviderMinimumrequirementsmaintenancecontractBestbangforthebuckMaintenancecontracts&servicerecordsWarranty

BICSI002