96
PAGE NO DESCRIPTION UNIT QUANTITY RATE AMOUNT SECTION NO. 1 BILL NO. 1 PRELIMINARIES NOTES i) The Agreement is to be the form of offer and acceptance (agreement) C1.1 of bid document and JBCC Series 2000 Principal Building Agreement, Edition 5.0m July 2007, including Contract Data EC and EC an all other JBCC support documentation that together from the contract between the Employer and Contractor ii) The Preliminaries are to be the Association of South African Quantity Surveyors (ASAQS) Preliminaries, November 2007 as amended for use with the JBCC Principal Building Agreement and shall be deemed to be incorporated herein iii) The Tenderer is deemed to have referred to these documents for the full intent and meaning of each clause. These clauses are referred to by number and heading only iv) Where standard clauses or options are not applicable to this contract such modifications, or corrections as, are necessary are given under each relevant clause v) Where any items are not relevant to this specific Agreement such items are marked NOT APPLICABLE in the amount columns (N/A) vi) Option A as set out in clause B10.3.1 hereinafter, is to be used for the adjustment of the preliminaries. Each item priced is to be allocated to one or more of the three categories, where "F" denotes fixed amount (amount which shall not be varied), "V" denotes an amount which shall be varied in proportion to the contract value as compared with the contract sum and "T" denotes an amount which shall be varied in proportion to the contract period. vii) Items not priced in these preliminaries shall be deemed to be included elsewhere and as priced as such viii) Should there be any discrepancy between these Preliminaries and the Agreement, these Preliminaries shall take precedence SECTION A : PRINCIPAL BUILDING AGREEMENT AGREEMENT DEFINITIONS (A1) Definitions and interpretation (clause 1) 1 F:........................... V:........................... T:............................... Item C2.2 BILLS OF QUANTITIES C2.2 Bills of Quantities Elandsfontein/Isando 1 of 96

C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

  • Upload
    others

  • View
    14

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

PAGE NO DESCRIPTION UNIT QUANTITY RATE AMOUNT

SECTION NO. 1

BILL NO. 1

PRELIMINARIES

NOTES

i)

The Agreement is to be the form of offer and acceptance (agreement) C1.1 of bid document

and JBCC Series 2000 Principal Building Agreement, Edition 5.0m July 2007, including

Contract Data EC and EC an all other JBCC support documentation that together from the

contract between the Employer and Contractor

ii)

The Preliminaries are to be the Association of South African Quantity Surveyors (ASAQS)

Preliminaries, November 2007 as amended for use with the JBCC Principal Building

Agreement and shall be deemed to be incorporated herein

iii)

The Tenderer is deemed to have referred to these documents for the full intent and meaning

of each clause. These clauses are referred to by number and heading only

iv)

Where standard clauses or options are not applicable to this contract such modifications, or

corrections as, are necessary are given under each relevant clause

v)

Where any items are not relevant to this specific Agreement such items are marked NOT

APPLICABLE in the amount columns (N/A)

vi)

Option A as set out in clause B10.3.1 hereinafter, is to be used for the adjustment of the

preliminaries. Each item priced is to be allocated to one or more of the three categories,

where "F" denotes fixed amount (amount which shall not be varied), "V" denotes an amount

which shall be varied in proportion to the contract value as compared with the contract sum

and "T" denotes an amount which shall be varied in proportion to the contract period.

vii)

Items not priced in these preliminaries shall be deemed to be included elsewhere and as

priced as such

viii)

Should there be any discrepancy between these Preliminaries and the Agreement, these

Preliminaries shall take precedence

SECTION A : PRINCIPAL BUILDING AGREEMENT

AGREEMENT

DEFINITIONS (A1)

Definitions and interpretation (clause 1)

1 F:........................... V:........................... T:............................... Item

C2.2 BILLS OF QUANTITIES

C2.2 Bills of Quantities

Elandsfontein/Isando 1 of 96

Page 2: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

OBJECTIVE AND PREPARATION (A2 TO A14)

Offer, acceptance and performance obligations (clause 2)

2 F:........................... V:........................... T:............................... Item

Documents (clause 3)

3 F:........................... V:........................... T:............................... Item

Design responsibility (clause 4)

4 F:........................... V:........................... T:............................... Item

Employer's agents (clause 5)

5 F:........................... V:........................... T:............................... Item

Contractor's site representative (clause 6)

6 F:........................... V:........................... T:............................... Item

Occupational Health and Safety Act, 1983

Without limiting the generality of the provisions of clause 7.1 of

the Agreement, the Contractor's attention is drawn to the

provisions of the Construction Regulations, 2007 issued in

terms of the Occupational Health and Safety Act, 1993. The

Contractor is to enter into an agreement with the Employer

shall prepare a documented Health and Safety specification for

the works (refer to part C5 for a copy of the specification) and

to ensure that the has made provision for the cost of health and

afety measures prescribed during the execution of the Works

7 F:........................... V:........................... T:............................... Item

Works risk (clause 8)

8 F:........................... V:........................... T:............................... Item

Indemnities (clause 9)

9 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 2 of 96

Page 3: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

General insurances (clause 10)

10 F:........................... V:........................... T:............................... Item

Special insurances (clause 11)

11 F:........................... V:........................... T:............................... Item

Effecting insurances (clause 12)

12 F:........................... V:........................... T:............................... Item

Assignment (clause 13)

13 F:........................... V:........................... T:............................... Item

Security (clause 14)

This clause shall be amended as follows:

14.1 The security required shall be as described in the bid

document and shall be in the form of cash, a certified cheque or

bank guarantee from a banking institution registered in terms of

the Banks Act 1990 (Act No 94 of 1990) or from an insurer

registered in terms of the Insurance Act 1943 (Act No 27 of

1943)

14.2 Such selected security shall be provided within fourteen

(14) calendar days of written acceptance of the contractor's

tender.

14.3 For second highest scoring bidder security shall be provided

notification of the contractor's tender.

14.2 No Clause

14.3 The Employer's entitlement to recover expense and loss

in terms of 33.0 shall take precedence over the reducing of the

surety or proportions thereof

14.4.1 A fixed construction guarantee to the value of 10% of the

contract amount shall be applicable

14.5 The parties shall expressly agree that neither the

Employer nor the Contractor shall be entitled to cede the rights

to the surety to any third party and the Employer shall apply the

security strictly according to the provisions of this agreement

14.6 Such selected security shall be provided within fourteen

(14) calendar days of written acceptance of the contractor's

tender

C2.2 Bills of Quantities

Elandsfontein/Isando 3 of 96

Page 4: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

The employer reserves the right to reject a construction

guarantee if, in the opinion of the employer, the guarantor is

not accredited

14 F:........................... V:........................... T:............................... Item

EXECUTION (A15 TO A23)

Preparation for and execution of the Works (clause 15)

15 F:........................... V:........................... T:............................... Item

Site and access (clause 16)

16 F:........................... V:........................... T:............................... Item

Contract instructions (clause 17)

In addition to the provisions of sub-clause 17.3, contract

instructions are to be recorded in triplicate in a contract

instruction book, which is to be supplied and maintained on

site by the Contractor

17 F:........................... V:........................... T:............................... Item

Setting out of the Works (clause 18)

The Contractor shall notify the Principal Agent if any

encroachments of adjoining foundations, buildings, structures,

pavements, boundaries, etc. exist in order to make the

necessary arrangements for the rectification of any such

encroachments

18 F:........................... V:........................... T:............................... Item

Temporary works and plant (clause 19)

19 F:........................... V:........................... T:............................... Item

Nominated Subcontractors (clause 20)

In addition to the provisions of sub-clause 20.1.2, the

Contractor shall, at any time on being requested to do so by the

Principal Agent, furnish a copy of the JBCC Nominated

Subcontract Agreement to the Employer, within five (5) working

days of such request

20 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 4 of 96

Page 5: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Selected Subcontractors (clause 21)

In addition to the provisions of sub-clause 21.1.3, the

Contractor shall, at any time on being requested to do so by the

Principal Agent, furnish a copy of the JBCC Selected

Subcontractor Agreement to the Employer, within five (5)

working days of such request.

21 F:........................... V:........................... T:............................... Item

Employer's Direct Contractors (clause 22)

22 F:........................... V:........................... T:............................... Item

Contractor's Domestic Subcontractors (clause 23)

In addition to the provisions of sub-clause 23.1, the Contractor

shall, at any time on being requested to do so by the Principal

Agent, furnish a copy of the Domestic Subcontract Agreement

of the Employer, within five (5) working days of such request

23 F:........................... V:........................... T:............................... Item

COMPLETION (A24 TO A30)

Practical Completion (clause 24)

24 F:........................... V:........................... T:............................... Item

Work completion (clause 25)

25 F:........................... V:........................... T:............................... Item

Final completion (clause 26)

26 F:........................... V:........................... T:............................... Item

Latent defects liability period (clause 27)

27 F:........................... V:........................... T:............................... Item

Sectional completion (clause 28)

28 F:........................... V:........................... T:............................... Item

Revision of date for practical completion (clause 29)

29 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 5 of 96

Page 6: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Penalty for late or non-completion (clause 30)

30 F:........................... V:........................... T:............................... Item

PAYMENT (A31 TO A35)

Interim payment (clause 31)

This clause amended to read that payment will be made by the

employer within thirty (30) days from date of receipt of a correct

Invoice by the EMM finance department

31 F:........................... V:........................... T:............................... Item

Clause 31 shall be deemed to be amended and extended as

follows:

31.6 Not withstanding the provisions of Clause 31.6 or any

other clause, material and goods stored off site shall not be

included in the amount authorized for payment unless

specifically authorized by the Employer

31.17 Retention Fund

31.17.1 The Employer shall withhold from the Contractor

retention of 10% up to a maximum amount of 5% of the contract amount

of all payments made before the issuing of the certificate of

practical completion. No interest is to be paid to the Contractor

on the retention. The retention fund shall be held by the

Employer as a guarantee to the Employer for the completion

of the contract.

31.17.2 Fifty percent (50%) of the retention fund shall be

released to the Contractor on the issuing of the certificate of

practical completion, and the remainder on the issuing of final

completion on certificate and acceptance of the final account..

Adjustment of the contract value (clause 32)

32 F:........................... V:........................... T:............................... Item

Recovery of expense and lose (clause 33)

33 F:........................... V:........................... T:............................... Item

Final account and final payment (clause 34)

34 F:........................... V:........................... T:............................... Item

Payment to other parties (clause 35)

35 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 6 of 96

Page 7: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

TERMINATION (A35 TO A39)

Termination by Employer - Contractor's default (clause 36)

36 F:........................... V:........................... T:............................... Item

Termination by Employer - loss and damages (clause 37)

37 F:........................... V:........................... T:............................... Item

Termination by Contractor - Employer's default (clause 39)

38 F:........................... V:........................... T:............................... Item

Termination - cession of the Works (clause 39)

39 F:........................... V:........................... T:............................... Item

CONTRACT AGREEMENT (A41)

POST TENDER PROVISION

Post tender provisions (clause 41)

40 F:........................... V:........................... T:............................... Item

41.1 Information provided

Clause applicable

41.2 Contract data

Clause applicable

41.3 Dispute resolution body

Clause applicable

41.4 Payment guarantee

Clause not applicable, employer shall not provide

payment guarantee

41.5 Building industry holiday

Clause applicable

41.6 Further provision

Clause applicable

CONTRACT DATA CE

1 Contracting party

Clause applicable

2 Securities

Applicable as amended in accordance with clause 14

C2.2 Bills of Quantities

Elandsfontein/Isando 7 of 96

Page 8: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

3 Payment and adjustment of preliminaries

3.1 Payment of preliminaries

Option B applicable (clause 3.2.5)

3.2 Adjustment of preliminaries

Option A applicable (clause 3.2.6)

3.2.3 Payment certificate, cash flow

Clause applicable

3.2.4 Contract value adjustment

The contract value shall be adjusted in accordance with

CPAP (3.11)

Base month - MONTH PRIOR TO CLOSING

DATE OF BIDS

The following CPAP be used for contract price adjustment:

The formula that will apply for CPAP adjustment is:

JBCC series 2000 Contract price adjustment

provisions,      latest edition

ADJUSTMENT FORMULA

A= 0.85 x V x (Xe/Xo-1)

where

A= adjustment

0.85= a constant which provides for 15% non

adjustable                   element

V= the work value in such work group and the valuation

period

Xe= the value of the index applicable to such work

group   and the valuation       period

Xo= the value of the index applicable to such work

group   for the base month

4.0 Employer changes to JBCC Standard Documents

4.1 Clause applicable

5.0 Tender

5.1 - 5.8.6 Tender and bid sum to be calculated in

terms of the conditions and offer in the

bid document

Tender shall remain in full legal force

for 120 calendar days

C2.2 Bills of Quantities

Elandsfontein/Isando 8 of 96

Page 9: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

CONTRACTUAL AGREEMENT (A42)

42.1 Agreement

Clause applicable

42.2 Contracting parties

Employer: EKURHULENI METROPOLITAN MUNICIPALITY

68 Woburn Avenue

Benoni

'1501

Tel (011) 999 6540 Fax (011) 999 7511

42.3 Contract Sum

Clause applicable

42.4 Signature of parties

Clause applicable

CONTRACT DATA EC

1.0 Contracting and other parties

1.1 Employer: Ekurhuleni Metropolitan Municipality

[1.2] 68 Woburn Avenue

Benoni

'1501

1.2 Principal Agent:

As nominated by employer

Clause applicable

1.3-1.8 As nominated by employer

Clause applicable

1.9 Interest of agents

Clause applicable

1.10 Contract data schedule

Clause applicable

2.0 Contract and site information

2.1 The law applicable to the agreement: RSA

2.2 Works identification

2.2.1 The construction of New Elandsfontein/Isando

Fire Station

2.3 Site identification

2.3.1 Erf 161, Planeet Road, Klopperpark,

Germiston

2.4 Possession of the site is to be given within a

period of 21 (Twenty-One) calendar days from acceptance of the

tender and compliance therewith

C2.2 Bills of Quantities

Elandsfontein/Isando 9 of 96

Page 10: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

2.5 Period for the commencement of the works

after the contractor takes possession of the

site

Within five (5) working days

2.6 Completion of the works sections is required

No

2.7 Waiver of the contractor's lien or right of

continuing possession is required

Yes

2.8 Define restrictions to site areas

Yes. As described in the Bills of Quantities

where applicable.

2.9 Geotechnical investigation of the site

Not applicable

2.10 Existing premises will be occupied

No. As described in the Bills of Quantities

where applicable.

2.11 Provision of temporary services is required

Yes

2.11.1 Water Option A Contractor - his cost

2.11.2 Electricity Option A Contractor - his cost

2.11.3 Telecom Option A Contractor - his cost

2.11.4 Ablutions Option A Contractor - his cost

2.12 Protection of existing trees and shrubs is

required

Yes. As described in the Bills of Quantities

where applicable.

3.0 Insurances and Securities

3.1 Contract works

As outlined in the contract data section

3.2 Supplementary/Special insurance

As outlined in the contract data section

3.3 Public liability insurance

As outlined in the contract data section

C2.2 Bills of Quantities

Elandsfontein/Isando 10 of 96

Page 11: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

3.4 Support insurance to be effected by the

employer

As outlined in the contract data section

3.5 Special insurance to be effected by [11.1.2-

3, 12.1]

As outlined in the contract data section

4.0 PRACTICAL COMPLETION DATES AND

PENALTIES

4.1 For the works as a whole the completion shall

be as stated in the contract data from the

date of possession of site

The penalty per calendar day

is R10 000,00 (Excluding VAT)

4.2 For the works in sections:

Not applicable

5.0 DOCUMENTS AND GENERAL

5.1 Construction document copies to be

supplied to the contractor free of charge

One (1)

5.2 The priced document may be used as a

specification of material and good and work

methods.

No

5.3 The contractor shall be required to provide

a schedule of rates.

Yes. As described in the Bills of Quantities

where applicable.

5.4 Changes made to JBCC standard

documents.

Yes as listed in the Contract Data

5.5 On acceptance of the tender the priced

document is to be submitted within the

stated working days.

Documents are to be submitted with bid

5.6 Work to be undertaken by direct

contractors (refer to contract data)

Yes

5.7 On achievement of practical completion the

contractor is to hand over manuals etc.

related to the works as listed by principal

agent

5.8 Interim payment certificate to be issued by

25 day of each month

C2.2 Bills of Quantities

Elandsfontein/Isando 11 of 96

Page 12: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

6.0 CHANGES MADE TO THE STANDARD JBCC

DOCUMENTS

Changes made detailed in the Contract Data

7.0 DECLARATION BY THE PRINCIPAL AGENT

Clause applicable

SECTION B: PRELIMINARIES

DEFINITION AND INTEPRETATION (B1)

Definition and Interpretation (B1.1 to B1.4.6)

41 F:........................... V:........................... T:............................... Item

DOCUMENTS (B2)

Checking of documents (B2.1)

42 F:........................... V:........................... T:............................... Item

Provisional bills of quantities (B2.2)

See Schedule of Variables (B12)

43 F:........................... V:........................... T:............................... Item

Availability of construction documentation (B2.3)

See Schedule of Variables (B12)

44 F:........................... V:........................... T:............................... Item

Interest of agents (B2.4)

See Schedule of Variables (B12)

45 F:........................... V:........................... T:............................... Item

Priced documents (B2.5)

Price documents to be submitted with all bid documents issued

Notwithstanding the provisions of this clause, the contractor

shall deposit/submit the priced documents within the time as

stated in 5.5 of the Data EC

Rates (items)

C2.2 Bills of Quantities

Elandsfontein/Isando 12 of 96

Page 13: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Where appropriate, rates for similar items in these bills of

quantities should be the same

46 F:........................... V:........................... T:............................... Item

Tender submission (B2.6)

This clause is amended by substituting "JBCC Form of Tender"

with "Official Form of Tender".

47 F:........................... V:........................... T:............................... Item

THE SITE (B3)

Defined works area (B3.1)

See Schedule of Variables (B12)

48 F:........................... V:........................... T:............................... Item

Geotechnical investigation (B3.2)

See Schedule of Variables (B12)

49 F:........................... V:........................... T:............................... Item

Inspection of the site (B3.3)

50 F:........................... V:........................... T:............................... Item

Existing premises occupied (B3.4)

See Schedule of Variables (B12)

51 F:........................... V:........................... T:............................... Item

Previous work - dimensional accuracy (B3.5)

52 F:........................... V:........................... T:............................... Item

Previous work - defects (B3.6)

53 F:........................... V:........................... T:............................... Item

Services - known (B3.7)

C2.2 Bills of Quantities

Elandsfontein/Isando 13 of 96

Page 14: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

See Schedule of Variables (B12)

54 F:........................... V:........................... T:............................... Item

Services - unknown (B3.8)

55 F:........................... V:........................... T:............................... Item

Protection of trees (B3.9)

See Schedule of Variables (B12)

56 F:........................... V:........................... T:............................... Item

Articles of value (B3.10)

57 F:........................... V:........................... T:............................... Item

Inspection of adjoining properties (B3.11)

See Schedule of Variables (B12)

58 F:........................... V:........................... T:............................... Item

MANAGEMENT OF CONTRACT (B4)

Management of the Works (B4.1)

The Contractor shall obtain all necessary particulars of

Subcontractors' work timeously so that provision for recesses,

chases, holes, etc. can be made

59 F:........................... V:........................... T:............................... Item

Programming for the works (B4.2)

60 F:........................... V:........................... T:............................... Item

61 Progress meetings (B4.3)

62 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 14 of 96

Page 15: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Technical meetings (B4.4)

63 F:........................... V:........................... T:............................... Item

Labour and plant records (B4.5)

64 F:........................... V:........................... T:............................... Item

SAMPLES, SHOP DRAWINGS AND

MANUFACTURERS INSTRUCTIONS (B5)

Samples of materials (B5.1)

65 F:........................... V:........................... T:............................... Item

Workmanship samples (B5.2)

66 F:........................... V:........................... T:............................... Item

Shop drawing (B5.3)

67 F:........................... V:........................... T:............................... Item

TEMPORARY WORKS AND PLANT (B6)

Deposits and fees (B6.1)

68 F:........................... V:........................... T:............................... Item

Enclosure of the works (B6.2)

See Schedule of Variables (B12)

69 F:........................... V:........................... T:............................... Item

Advertising (B6.3)

Advertisements on the hoarding or elsewhere on the site will be

allowed, subject to the written approval of the Principal Agent

70 F:........................... V:........................... T:............................... Item

Plant, equipment, sheds and offices (B6.4)

In addition to the provisions of sub-clause 6.4.1, scaffolding

shall not be permitted to be erected from buildings on adjacent

sites.

See Schedule of Variables (B12)

71 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 15 of 96

Page 16: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Main notice board (B6.5)

See Schedule of Variables (B12)

72 F:........................... V:........................... T:............................... Item

Subcontractors notice board (B6.6)

See Schedule of Variables (B12)

73 F:........................... V:........................... T:............................... Item

TEMPORARY SERVICES (B7)

Location (B7.1)

74 F:........................... V:........................... T:............................... Item

75 Water (B7.2)

See Schedule of Variables (B12)

76 F:........................... V:........................... T:............................... Item

77 Electricity (B7.3)

See Schedule of Variables (B12)

78 F:........................... V:........................... T:............................... Item

79 Telecommunication equipment (B7.4)

See Schedule of Variables (B12)

80 F:........................... V:........................... T:............................... Item

Ablution facilities (B7.5)

See Schedule of Variables (B12)

81 F:........................... V:........................... T:............................... Item

PRIME COST AMOUNTS (B8)

Responsibility for prime cost amounts (B8.1)

82 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 16 of 96

Page 17: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

ATTENDANCE ON NOMINATED/SELECTED

SUBCONTRACTORS (B9)

General Attendance (B9.1)

In addition to the provisions of clause B9.1, the Contractor

shall, at his own expense, provide the following additional

general attendance:

Make good after Nominated/Selected Sub-contractors

83 F:........................... V:........................... T:............................... Item

Special attendance (B9.2)

See Schedule of Variables (B12)

84 F:........................... V:........................... T:...............................

Commissioning - Fuel, water and power (B9.3)

85 F:........................... V:........................... T:............................... Item

FINANCIAL ASPECTS (B10)

Statutory taxes, duty and levies (B10.1)

In addition to the provisions of clause B10.1, all individual

amounts in these bills of quantities exclude Value Added Tax

(VAT). VAT is to be calculated as a lump sum and added to the

total value of all value in the Final Summary under the item

provided for VAT

86 F:........................... V:........................... T:............................... Item

Payment of preliminaries (B10.2)

See Schedule of Variables (B12)

87 F:........................... V:........................... T:............................... Item

Adjustment of preliminaries (B10.3)

Notwithstanding the provisions of sub-clause B10.3.1

(Alternative A) and for the purpose of adjusting the Time

Related amount, only revision of the date for practical

completion granted by the Employer for variations, omissions,

additions and substitutions referred to in sub-clauses 29.2 and

29.3 of the Principal Building Agreement, shall be taken into

account

88 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 17 of 96

Page 18: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Payment certificate cash flow (B10.4)

89 F:........................... V:........................... T:............................... Item

GENERAL (B11)

Protection of the Works (B11.1)

See Schedule of Variables (B12)

90 F:........................... V:........................... T:............................... Item

Protection/isolation of existing/section ally occupied Works

(B11.2)

See Schedule of Variables (B12)

91 F:........................... V:........................... T:............................... Item

Security of the works (B11.3)

92 F:........................... V:........................... T:............................... Item

Notice before covering work (B11.4)

93 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 18 of 96

Page 19: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Disturbance (B11.5)

See Schedule of Variables (b12)

94 F:........................... V:........................... T:............................... Item

Environmental disturbance (B11.6)

95 F:........................... V:........................... T:............................... Item

Works cleaning and clearing (B11.7)

96 F:........................... V:........................... T:............................... Item

Vermin (B11.8)

97 F:........................... V:........................... T:............................... Item

Overhand work (B11.9)

98 F:........................... V:........................... T:............................... Item

Instruction Manuals and guarantees (B11.10)

99 F:........................... V:........................... T:............................... Item

As built information (B11.11)

100 F:........................... V:........................... T:............................... Item

Tenant Installation (B11.12)

101 F:........................... V:........................... T:............................... Item

SCHEDULE OF VARIABLES (B12)

PRE-TENDER INFORMATION

Pre-tender information (B12.1)

102 F:........................... V:........................... T:............................... Item

12.1.1 Provisional bills of quantities (B2.2)

The quantities are provisional:

Yes

12.1.2 Availability of construction documentation (B2.3)

Construction documentation is complete:

No

C2.2 Bills of Quantities

Elandsfontein/Isando 19 of 96

Page 20: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

12.1.3 Interests of agents (B2.4)

The agents have no interest in this project apart

from their professional interest

12.1.4 Defined Works area (B3.1)

The works will be defined and restricted to specific

areas only as determined by the Principal Agent and

shall be dealt with at the compulsory site inspection

meeting

12.1.5 Geotechnical investigation (B3.2)

Not applicable. The geotechnical report shall be made

available on request should it be necessary.

12.1.6 Existing premises occupied (B3.4)

No

12.1.7 Previous work - dimensional accuracy (B3.5)

No

12.1.8 Previous work defects (B3.6)

No

12.1.9 Services - known (B3.7)

As shown on drawings

12.1.10 Protection of trees (B3.9)

No trees are to be removed without prior instruction

by the Principal Agent and existing trees to be

protected from damage for the full duration of the

contract

12.1.11 Inspection of adjoining properties (B3.11)

Yes

12.1.12 Enclosure of the Works (B6.2)

Contractor to make provision for own enclosures,

temporary barriers, etc. of the works. If permanent

site fencing is utilized contractor is to maintain same

for the duration of the contract. The works shall also be

enclosed off the main road construction and

landscaping

12.1.13 Offices (B6.4.3)

One site office shall be minimum 3 x 3 x 3m

high internally, suitably insulated and ventilated,

provided with electric light an fitted with boarded

floor, table and adequate chairs

One site meeting room shall be minimum 6 x 3 x 3m

high internally, suitably insulated and ventilated,

provided with electric light an fitted with boarded

floor, table and adequate chairs

C2.2 Bills of Quantities

Elandsfontein/Isando 20 of 96

Page 21: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

12.1.14 Main notice board (B6.5)

One main notice board shall be strongly made,

2,17m wide and 1,715m high, with 19mm thick

surround projecting 13mm over face the board

is to have a flush even surface and is to be

divided into four sections and painted navy blue

and ivory white

The lettering is to be 50mm and 100mm "sans

serif" in ivory white on the blue background and

in 100mm "sans serif" in navy blue and the ivory

whited background. The inscription, is on

language only, which must bear the approval of

the Employer, will be given to the Contractor by

the Principal Agent. The board must be

adequately supported no other names or notice

boards may be erected without the written

approval of the Principal Agent

Sketch drawings of all proposed names or

notice boards must be submitted to the

Principal Agent for approval, before being

prepared and erected on site these sketch

drawings must not only show the full content of

the proposed names or notice boards, but also

the position and locality in which the boards

will be erected.

The notice board shall be relocated from site to site

once initial site has been completed

12.1.15 Subcontractor notice board (B6.6)

A notice board is required:

No

12.1.16 Water (B7.2)

Option A applicable

12.1.17 Electricity (B7.3)

Option A applicable

12.1.18 Telecommunication (B7.4)

Telephone - Yes

Facsimile - Yes

Email - Yes

12.1.19 Ablution facilities (B7.5)

Option A applicable

12.1.20 Protection of existing/section ally occupied works

(B11.2)

Protection is required:

No

12.1.21 Special attendance (B9.2)

Not applicable

C2.2 Bills of Quantities

Elandsfontein/Isando 21 of 96

Page 22: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

12.1.22 Protection of the works (B11.1)

The sections where construction works is in

progress needs to be barricaded and sealed off from

access to the general public

12.1.23 Disturbance (B11.5)

Contractor to take note that the works is to be

carried out within public areas and precaution is to

be taken with regard to minimizing disturbance, dust,

movement, noise, etc. Steps for prevention and

minimization of above factors will be pre-determined

on site with the Principal Agent.

12.1.24 Environmental disturbance (B11.60)

Clause applicable

No specific requirements

POST-TENDER INFORMATION

Post-tender information (B12.2)

103 F:........................... V:........................... T:............................... Item

12.2.1 Payment preliminaries

Option B applicable

12.2.2 Adjustment of preliminaries

Option B applicable

12.2.3 Additional agreed preliminaries items: No

C2.2 Bills of Quantities

Elandsfontein/Isando 22 of 96

Page 23: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION C: SPECIFIC PRELIMINARIES

PROPRIETARY BRANDED PRODUCTS

The contractor shall take delivery of, handle, store, sure apply

and/or fix all proprietary branded products in strict accordance

with the manufacturers' instruction after consultation with the

manufacturer's authorised representative

104 F:........................... V:........................... T:............................... Item

OVERTIME

Should overtime be required to be work for any reason

whatsoever, the costs of such overtime are to be borne by the

contractor unless the principal agent has specifically authorised

in writing, prior to the execution thereof, that costs for such

overtime are to be borne by employer

105 F:........................... V:........................... T:............................... Item

AS BUILT DRAWINGS

The position of construction breaks and the extent of

individual concrete pours are to be recorded by the contractor

on the structural engineer's drawings and are to be submitted to

the principal agent and the structural engineer for their records

106 F:........................... V:........................... T:............................... Item

SITE INSTRUCTIONS

Site instructions issued on site are to be recorded in triplicate in

a site instruction book which is to be maintained on site by the

contractor

107 F:........................... V:........................... T:............................... Item

LABOUR RECORD

At the end of each week the contractor shall provide the

principal agent with a written record, in schedule form, reflecting

the number and description of tradesmen and labourers

employed by him and all subcontractors on the works each day

108 F:........................... V:........................... T:............................... Item

PLANT RECORD

At the end of each week the contractor shall provide the

principal agent with a written record, in schedule form, reflecting

the number, type and capacity of al plant, excluding hand tools,

currently used on the works

NON CESSION OF MONIES

The contractor shall not cede nor assign his rights or claims to

any monies due or to become due under this contract

109 F:........................... V:........................... T:............................... Item

C2.2 Bills of Quantities

Elandsfontein/Isando 23 of 96

Page 24: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

GENERAL SPECIFICATION

The general specification for the works is the Model Preambles

for Trades November 2008 as published by the Association of

Quantity Surveyors. Tenderers are to acquaint themselves of

the full contract thereof and the document will be deemed to be

part of the conditions of tender and contract

110 F:........................... V:........................... T:............................... Item

OCCUPATIONAL HEALTH AND SAFEY ACT - SECTION

37(2)

The tenderers attention is drawn to the fact that the

Occupational Health and Safety Act (Act 85 of 1993) is in force.

Copies of the Act are available from the Government Printing

Works, 149 Bosman Street, Pretoria, (Private Bag X85,

Pretoria, 0001, Tel No. (012) 334-4500).

Tenderers are expected to be fully acquainted with the

requirements of the Act

A pro-forma "Agreement in terms of the Occupational Health

and Safety Act - Pat C 1.4" is included in these bid documents.

Tenderers are advised to study this pro-forma in order to make

themselves fully conversant with the requirements and

responsibilities of the Act and the Municipality.

The tenderers are to provide for the above-mentioned

requirements and to allow for all cost implications regarding the

above including risk assessment, safety plan and monitoring

the system for the duration of the contract.

111 F:........................... V:........................... T:............................... Item 1

COMMUNITY EMPLOYMENT AND SMME

INVOLVEMENT

The building related projects of the EMM shall be labour

intensive and shall promote community employment in the

execution of the contract resulting form their tender.

Furthermore, it shall contribute to the development of SME's

(Small and Medium Enterprises) especially from previously

disadvantaged communities

 A minimum of 30% of the contract value must be  utilised in payment of at least one or more of

the following:

(a)               Emerging sub-contractors

(b)               Emerging suppliers

(c)               Local labour

(d)               Or similar local content as approved by the employer.

Local Labour

C2.2 Bills of Quantities

Elandsfontein/Isando 24 of 96

Page 25: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

It is an explicit condition of this contract that only persons

normally resident in the locality of the works (Local Labour) may

be employed on the contract. Provided however, that should

adequate and appropriate labour not be available within the

locality, other labour may be employed, subject to the approval

of the Representative/Agent and satisfactory proof being

provided that every reasonable endeavour has been made, to

employ labour from the immediate locality. The contractors

shall identify the local community leaders, with the purpose of

negotiation with them, regarding utilisation of local labour in

the construction process. In this regard, the Contractor shall

furthermore give preference, where possible, to the

employment of women, youth and disabled

persons. The Contractor shall in general, maximize the

involvement of the local community

112 F:........................... V:........................... T:............................... Item

SPECIFIC GOAL PARTICIPATION

Tenderers should note that this project is subject to the

maximum utilization of women, youth and disabled and

preference will be given as such and also monitored during the

construction stage.

Details of the tenderers proposals in this regard is to be

provided before commencement of the works and data forms

to be completed by the contractor

113 F:........................... V:........................... T:............................... Item

EXTENDED PUBLIC WORKS PROGRAMME (EPWP) REQUIRMENTS

Tenderers should note that this project is partly funded by the

Provincial Government under their Expanded Public Works

Programme (EPWP) and that certain requirements in terms of

the programme will be applicable in addition to the prescribed

conditions of this tender with regard to registration of the

contractor, supplying and issuing of training and employment

statistics on a monthly basis

C2.2 Bills of Quantities

Elandsfontein/Isando 25 of 96

Page 26: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

F:........................... V:........................... T:............................... Item

114 NON ACCREDITED TRAINING

The Contractor shall be responsible to employ and provide training to youth workers as

stipulated by the Expanded Public Works Programme (EPWP) and National Youth Service

(NYS). Allow the amount R250 000 (Two Hundred and Fifty Thousand Rand) for compliance

with EPWP/NYS requirements to be deducted in whole and actual paid amount added

Details of the tenderer's proposals in this regard is to be

provided before commencement of the works by the Contractor

for approval by the Representative Agent

115 F:........................... V:........................... T:............................... Item R 250 000.00

COMMUNITY LIAISON OFFICER (CLO)

The successful tenderer shall enter into an agreement with the Community Liaison Officer

(CLO), nominated by the Local Ward Council for liason with the recipient community. This

agreement shall make provision for the payment by the Contractor of a monthly wage to the

CLO based on the minimum wage recommended by the Local Council. Allow the amount of

R200 000 (Two Hundred Thousand Rand) for remuneration of the Community Liaison Officer

(CLO) to be deducted in whole and actual paid amount added

F:........................... V:........................... T:............................... Item 1

SUMMARY OF PRELIMINARIES

Tenderer's to submit breakdown of overall preliminaries as

indicated hereunder

Total preliminaries:

1. Fixed related R_________________________

2. Valued related R_________________________

3. Time related R_________________________

Carried to Section Summary

Carried to Final Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 26 of 96

Page 27: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION No. 2

BILL No. 1

EARTHWORKS (PROVISIONAL)

SUPPLEMENTARY PREAMBLES

Nature of ground

Use "assumed to be" if no trial holes, soils investigations, etc have been carried out - discuss

with engineer. Use "Trial holes indicate that" where the ground has been investigated by

means of trial holes

Nature of ground

A soils investigation has been carried out on site by the engineer and the report is annexed to

these bills of quantities. Descriptions of excavations shall be deemed to include all ground

conditions classifiable as "earth" described in the above report and where conditions of a more

difficult character are indicated these are separately measured

Carting away of excavated material

Descriptions of carting away of excavated material shall be deemed to include loading

excavated material onto trucks directly from the excavations or, alternatively, from stock piles

situated on the building site

TEMPORARY BARRIERS, SCREENS, ETC

Temporary barriers, screens, etc including removal

1

Diamond mesh fencing 2,100mm high including green shade netting, posts, uprights, etc

complete and removing and making good on completion of the works m 421

2

Galvanised steel double gate overall size 6,000 x 2,100mm high including green shade

netting, posts, uprights, etc complete and removing and making good on completion of works No 1

SITE CLEARANCE ETC

Site clearance

3

Digging up and removing rubbish, debris, vegetation, hedges, shrubs and trees not exceeding

200mm girth, bush, etc m2 13571

4 Stripping average 150mm thick layer of top soil and stockpiling on site m2 13571

REMOVAL OF TREES ETC

Taking out and removing, grubbing up roots and filling in holes

5 Tree stump exceeding 200mm and not exceeding 500mm girth No 5

6 Tree stump exceeding 500mm and not exceeding 1000mm girth No 2

BULK EXCAVATION, FILLING, ETC

Open face excavation in earth for soil raft

7 Open face excavation to form platforms, etc m3 253

C2.2 Bills of Quantities

Elandsfontein/Isando 27 of 96

Page 28: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Extra over bulk excavation in earth for excavation in

8 Soft rock m3 25

9 Hard rock m3 13

Extra over all excavations for carting away

10

Surplus material from excavations and/or stock piles on site to a dumping site to be located by

the contractor m3 253

Keeping excavations free of water

11 Keeping excavations free of all water other than subterranean water Item 1

Backfilling of excavation to construct soil raft with material obtained from excavations

compacted in 150mm layers to 95% Mod AASHTO density at -1% to +2% of OMC

12 Over site to make up levels m3 42

Back filling of excavation with G5 imported granular material compacted in 150mm thick layers

to 93% Mod AASHTO density at -1% to +2% of OMC

13 Over site to form platforms m3 187

Coarse river sand filling supplied by the contractor compacted to 100% Mod AASHTO density

14 Under floors, steps, pavings, etc m3 372

Compaction of surfaces

15

Compaction of ground surface under floors etc including scarifying for a depth of 150mm,

breaking down oversize material, adding suitable material where necessary and compacting to

93% Mod AASHTO density m2 1877

Prescribed density tests on filling

16 Mod AASHTO density test No 51

17 DCP "dinamic cone penetration" tests No 6

GEOTEXTILE

Supply and installation of RockPC 100/100 geotextile to manufacturer specification or similar

approved

18 To soil raft m2 1877

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 2

FOUNDATIONS

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

C2.2 Bills of Quantities

Elandsfontein/Isando 28 of 96

Page 29: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SUPPLEMENTARY PREAMBLES

Nature of the ground

The Tenderer shall acquaint himself by personal examination of the nature of the ground.

Descriptions of excavations shall be deemed to include all ground conditions classifiable as

"earth" and where conditions of a more difficult character are indicated these are separately

measured

Carting away of excavated material

Descriptions of carting away of excavated material shall be deemed to include loading

excavated material onto trucks directly from the excavations or alternatively, from stock piles

situated on the building site

EXCAVATION, FILLING, ETC OTHER THAN BULK

Excavation in earth not exceeding 2m deep

1 Trenches m3 645

2 Holes m3 109

Extra over trench and hole excavations in earth for excavation in

3 Soft rock m3 151

4 Hard rock m3 75

Extra over all excavations for carting away

5

Material from excavations and/or stock piles on site to a dumping site to be located by the

Contractor m3 591

Risk of collapse of excavations

6 Sides of trench and hole excavations not exceeding 1.5m deep m2 3864

Keeping excavations free of water

7 Keeping excavations free of all water other than subterranean water Item 1

Earth filling obtained from excavations compacted to 93% Mod AASHTO density

8 Backfilling to trenches, holes, etc m3 112

Earth filling of G5 material supplied by the contractor and compacted to 98% Mod AASHTO

density

9 Under floors, stairs etc. m3 472

Clean river sand filling supplied by the contractor compacted to 100% Mod AASHTO density

10 Under floors, steps, pavings, etc m3 282

SOIL POISONING

Approved insecticide applied in strict accordance to the manufacturers instruction

11

Under floors etc including forming and poisoning shallow furrows against foundation walls etc,

filling in furrows and ramming m2 1877

12 To bottoms and sides of trenches etc m2 2990

C2.2 Bills of Quantities

Elandsfontein/Isando 29 of 96

Page 30: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

CONCRETE

UNREINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

Class 20MPa/19mm concrete

13 Surface blinding under column bases, footings, etc m3 29

REINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

Class 30MPa/19mm concrete

14 Strip footings m3 51

15 Ground beams m3 183

16 Bases m3 44

TEST BLOCKS

17 Making and testing set of three 150 x 150 x 150mm concrete strength test cubes No 50

REINFORCEMENT

Mild steel reinforcement to structural concrete work

18 16mm Diameter bars t 0.16

19 12mm Diameter bars t 0.16

20 10mm Diameter bars t 0.98

21 8mm Diameter bars t 0.98

C2.2 Bills of Quantities

Elandsfontein/Isando 30 of 96

Page 31: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

High tensile steel reinforcement to structural concrete work

22 32mm Diameter bars t 1.15

23 25mm Diameter bars t 1.15

24 20mm Diameter bars t 1.97

25 16mm Diameter bars t 10.5

26 12mm Diameter bars t 10.83

27 10mm Diameter bars t 15.59

Total Carried Forward To Section Summary

SECTION No 2

BILL No 3

CONCRETE, FORMWORK AND REINFORCEMENT

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Cost of tests

The costs of making, storing and testing of concrete test cubes as required under Clause 7

"Tests" of SABS 1200 G shall include the cost of providing cube moulds necessary for the

purpose, for testing costs and for submitting reports on the tests to the Architect. The testing

shall be undertaken by an independent firm or institution nominated by the Contractor to the

approval of the Architect (Test cubes are measured separately)

Formwork

Descriptions of formwork shall be deemed to include use and waste only (except where

described as "left in" or "permanent"), for fitting together in the required forms, wedging,

plumbing and fixing to true angles and surfaces as necessary to ensure easy release during

stripping and for reconditioning as necessary before re-use. The vertical strutting shall be

carried down to such construction as is sufficiently strong to afford the required support without

damage and shall remain in position until the newly constructed work is able to support itself

Formwork to soffits of solid slabs, etc shall be deemed to be to slabs not exceeding 250mm

thick unless otherwise described Formwork has been measured to the sides of all reinforced

concrete in foundations and will be remeasured according to actual usage. However,

formwork necessitated by irregularity or collapse of excavated faces will not be measured and

the cost thereof shall be deemed to be included in the allowance for taking the risk of collapse

of the sides of the excavations, provision for which is made in "Earthworks"

CONCRETE

UNREINFORCED CONCRETE

15MPa/19mm concrete

1 Plinth m3 0.4

C2.2 Bills of Quantities

Elandsfontein/Isando 31 of 96

Page 32: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

REINFORCED CONCRETE

Class 30 Mpa/19mm concrete

2 Surface beds cast in panels on waterproofing m3 281

3 Apron slabs cast in panels on waterproofing m3 46

4 Thickening in apron slabs m3 10

5 Slabs including beams and inverted beams m3 13

6 Roof slabs including upstand beams m3 20

7 Stairs including landings, beams and inverted beams m3 3

8 Ring beams m3 40

9 Walls m3 39

10 Columns m3 0.4

CONCRETE SUNDRIES

Finishing top surfaces of concrete smooth with a power float

11 Surface beds, slabs, etc. m2 984

Finish top surface of concrete smooth with a wooden float

12 Surface beds, slabs, etc. m2 1379

13 Concrete to falls and currents m2 77

Finish top surface of concrete smooth with a wood float. Add oxide paint to achieve pigmented

charcoal colour finish.

14 Concrete to falls and currents to aprons m2 298

Take delivery of, set up in exact position and cast holding down bolt, frame, etc, into concrete

15 Set of four holding down bolts No 30

GROUTING

25 MPa non-shrink cementitious grout

16 25mm Cementitious grout below steel base plates as per engineer specification m2 5

ROUGH FORMWORK (DEGREE OF ACCURACY II)

Rough formwork to sides

17 Walls m2 104

18 Walls with total height exceeding 8.5m and not exceeding 9.0m above bearing level m2 70

19 Rectangular columns with total height not exceeding 3,5m above bearing level m2 6

20 Edges, risers, ends and reveals not exceeding 300mm high or wide m 25

SMOOTH FORM WORK (DEGREE OF ACCURACY I)

Formwork to sides

21 Inverted beams m2 19

22 Inverted beams above concrete m2 11

23 Edges, risers, ends and reveals not exceeding 300mm high or wide m 21

C2.2 Bills of Quantities

Elandsfontein/Isando 32 of 96

Page 33: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

24 Sloping and stepped outer edges of stairs not exceeding 300mm high extreme m 5

Formwork to soffits

25 Slabs propped up exceeding 1.5m and not exceeding 3.5m high m2 155

26 Landings m2 9

27 Stairs with sloping soffits m2 5

Formwork to sides and soffits

28 Isolated beams propped up exceeding 3m and not exceeding 3,5m high m2 361

Boxing in smooth formwork to form

29 25 x 25mm Vertical chamfer at corners to columns m 21

30 25 x 25mm Chamfer along top or bottom edge m 75

MOVEMENT JOINTS ETC

Saw cut joints

31 Saw cut joint as per engineer specification m 96

Construction joints

32 Construction joint as per engineer specification m 96

Isolation joints with "Jointex" between all vertical column and brick wall interface

33 10mm Joints not exceeding 300mm wide m 80

Expansion joints with "Flexcell" impregnated fibreboard between concrete surfaces

34 10mm Joints not exceeding 300mm wide m 50

REINFORCEMENT

Mild steel reinforcement to structural concrete work

35 16mm Diameter bars t 0.17

36 12mm Diameter bars t 0.17

37 10mm Diameter bars t 1.01

38 8mm Diameter bars t 1.01

High tensile steel reinforcement to structural concrete work

39 32mm Diameter bars t 1.18

40 25mm Diameter bars t 1.18

41 20mm Diameter bars t 2.02

42 16mm Diameter bars t 10.75

43 12mm Diameter bars t 11.09

44 10mm Diameter bars t 15.96

Total Carried Forward To Section Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 33 of 96

Page 34: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION 2

BILL No. 4

MASONRY

MODEL PREAMBLES FOR TRADES

NOTE:Tenderers are advised to study the Model Preambles for Trades before pricing this bill

SUPPLEMENTARY PREAMBLES

BRICKWORK

Sizes in descriptions

Where sizes in descriptions are given in brick units, "one brick" shall represent the length and

"half brick" the width of a brick

Hollow walls, etc

Descriptions of hollow walls shall be deemed to include leaving every fifth perpend of the

bottom course of the external skin open as a weep hole Walls in two skins described as

"bagged and sealed" shall be deemed to include having the outer face of the inner skin bagged

with 1:6 cement and sand mixture and sealed with two coats "Brixeal" bitumen emulsion

waterproofing coating

Pointing

Descriptions of recessed pointing to fair face brickwork and face brickwork shall be deemed to

include square recessed, hollow recessed, weathered pointing, etc

C2.2 Bills of Quantities

Elandsfontein/Isando 34 of 96

Page 35: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Bagged brick finish

Bagged brickwork shall be of the mortar as described rubbed onto wall with hessian cloth to

provide a fair finish. The finished surface shall be free of penetrations or pitted openings or

large protruding lumps of mortar. The finish shall be to the principal agent's approval

Face bricks

Bricks shall be ordered timeously to obtain uniformity in size and colour

Pointing

Descriptions of recessed pointing to fair face brickwork and face brickwork shall be deemed to

include square recessed, hollow recessed, weathered pointing, etc

Samples

Samples of all masonry building units, except those for walls described as "load bearing", shall

consist of a minimum of six units. Samples of building units to be used in walls described as

"load bearing" shall consist of thirty units from every thirty thousand units delivered to site

BRICKWORK

SUPERSTRUCTURE

Brickwork of "NFP" burnt clay bricks (7MPa nominal compressive strength) in Class II mortar

1 80mm Cut linings to concrete m2 10

2 Half brick walls m2 502

3 Half brick walls in beamfilling m2 56

4 One brick walls m2 2149

5 One brick yard walls including wire ties m2 86

Mortar strength test cubes

6 Making and testing 100 x 100 x 100mm mortar strength test cube No 15

Joint forming material in movement joints

7 8mm Bitumen impregnated fibre board built in vertically between brick skins m2 74

8 8mm Bitumen impregnated fibre board built in vertically between brick and concrete surfaces m2 255

Mesh reinforcement

9 Type 617 in brick shear walls m2 111

Brickwork reinforcement

10 75mm Wide reinforcement built in horizontally m 1477

11 150mm Wide reinforcement built in horizontally m 6321

Fabricated prestressed precast concrete lintels

12 110 x 75mm Lintels in lengths not exceeding 3m m 221

13 110 x 75mm Lintels in lengths exceeding 3m and not exceeding 4,5m m 75

14 110 x 75mm Lintels in lengths exceeding 4,5m and not exceeding 6m m 63

C2.2 Bills of Quantities

Elandsfontein/Isando 35 of 96

Page 36: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Galvanised hoop iron cramps, ties, etc

15

30 x 1,6mm Roof tie 1,5m long built into brickwork with both sides wrapped over steel beam,

fixed onto beam with "Hilti" shot-fired steel pins No 234

FACE BRICKWORK

"Firelight Satin" or equivalent and approved clay facebricks pointed with recessed horizontal

and vertical joints

16 Extra over brickwork for face brickwork m2 922

Brick-on-edge header course copings, sills, etc of 'Firelight Satin' or equivalent and approved

face bricks pointed with recessed joints on all exposed faces

17 Coping on top of one brick wall m 94

18 230mm Wide sill set level and slightly projecting m 16

PAVING

Paving is to be laid in accordance with SABS 1200 MJ, SABS 1058 and the Concrete Masonry

Association's specifications

50mm "Smart Stone Magalies" or equivalent and approved paving bricks with butt joints on

50mm thick river sand bed mixed with 10% dry cement with sand and cement mixture swept

into joints and hosed down including all necessary preparation of ground or filling, setting out,

cutting, etc complete

19 Paving in herringbone pattern to falls and currents m2 920

20 Straight cut paving joint m 90

21 220mm Wide brick-on-flat header course edging on 25mm thick mortar bed m 110

22 220mm Wide brick-on-flat header course edging m 434

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 5

WATERPROOFING

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Waterproofing

Waterproofing of roofs, basements, etc shall be laid under a ten year guarantee.

Waterproofing to roofs shall be laid to even falls to outlets, etc with necessary ridges, hips and

valleys. Descriptions of sheet or membrane waterproofing shall be deemed to include

additional labour to turn-ups and turn-downs

DAMPPROOFING OF WALLS AND FLOORS

One layer of 375 micron "Consol Plastics Brikgrip DPC" or equivalent and approved embossed

damp proof course

1 In walls m2 162

C2.2 Bills of Quantities

Elandsfontein/Isando 36 of 96

Page 37: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

One layer of 250 micron "Consol Plastics Gunplas USB Green" or equivalent and approved

waterproof sheeting sealed at laps with "Gunplas Pressure Sensitive Tape"

2 Under surface beds m2 6819

One layer Derbigum CG3 and one layer Derbigum CG4H (horticultural) waterproofing

membrane, with 100mm side laps and 150mm end laps, sealed by 'torch-fusion' to primed

surfaces, followed by 150 micron polythene sheeting loose laid with 100mm laps sealed with

pressure sensitive tape, to receive Delta MS20P (perforated) high density polyethylene

dimpled drainage layer and followed by one layer of Bidim A2 Geofabric and landscaping

(elsewhere specified). Waterproofing to be installed by an Approved Derbigum Contractor.

3 On planter walls m2 88

WATERPROOFING TO FLOORS, ROOFS, BASEMENTS, ETC

One layer 4mm thick "Derbigum SP" waterproofing system with a min of 300mm lapping

applied strictly according to manufacturers specifications

4 On roofs to falls m2 115

5 On tops and sides of inverted beams m2 107

6 Additional membrane at rainwater outlet No 4

Pro-drain polypropolene sheet of 5mm Thickness laid with overlaps on top of waterproofing

membrane to suppliers specification

7 On roofs to falls m2 115

PROTECTIVE ROOFING PAINT

Two coats bituminous aluminium paint

8 On waterproofing to roofs m2 134

19-25mm "Worcester Brown" crushed stone dressing evenly spread with larger stones around

outlets

9 50mm Thick on waterproofing to roofs m2 115

JOINT SEALANTS, ETC

Approved silicone sealing compound including primer, etc

10 Pointing between frames and walls m 550

11 Pointing to 6mm saw cut joints m 96

"Thioflex" two-part grey polysulphide sealing compound including backing cord, bond breaker,

primer, etc

12 10 x 10mm In vertical and horizontal expansion joints m 50

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 6

ROOF COVERINGS, ETC

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

C2.2 Bills of Quantities

Elandsfontein/Isando 37 of 96

Page 38: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SUPPLEMENTARY PREAMBLES

Fixing

All side cladding shall be fixed to purlins through the narrow flutes of the sheeting

Straight cutting

Descriptions of all roof coverings are deemed to include for all straight cutting

Flashings

Prior to flashings being fixed, all troughs at the apex shall be stop-ended to the full depth of the

sheet in order to prevent any penetration of wind driven water. The trough shall be lipped at

the eaves end to form a drip. Transverse flashing flanges shall be notched to the sheet profile

where necessary

Certificate for galvanised roof sheeting

The contractor is to submit a certificate signed by the merchant, stating that the galvanised roof

covering supplied, complies with the required thickness specified.

PROFILED METAL SHEETING AND ACCESSORIES

0,58mm "Klip-Tite" or equivalent and approved concealed-fix type" aluminium roof sheeting

and accessories, fixed to steel purlins or rails, with 12x 65mm long class 3 metal self drilling

screws at every second crest, at intermediate purlins and at every crest at eaves purlins, side

laps to be stitched at 500mm centres between purlins, all in accordance with manufacturers

recommendations (Colour: Charcoal)

1

Roof covering with pitch not exceeding 25 degrees, fixed to steel purlins, in transportable

lengths not exceeding 20m m2 2475

2 Side cladding m2 482

3 Gable trim 462mm girth 3 times bent m 182

4 Sidewall flashing 462mm girth 2 times bent m 79

5 Headwall flashing 462mm girth 2 times bent m 263

6 Counter flashing 185mm girth 2 times bent m 342

7 Apron flashing 305mm girth 2 times bent m 266

8 Apex flashing 660mm girth 3 times bent m 99

9 Corner trim 736mm girth 3 times bent m 353

10 Drip flashing 231mm girth 3 times bent m 192

11 Narrow and broad flute closers 150mm girth m 309

12 Moulded narrow and broad rib polyethylene filler blocks m 309

ROOF AND WALL LINING AND INSULATION

50mm Thick non-combustible, lightweight "Factorylite" or equivalent and approved aluminium

foil faced insulation, with Class I fire rating in accordance with SANS 428 of the National

Building Regulations, installed with foil side facing down

13

Insulation laid taut over purlins and fixed concurrent with battens, purlins, etc including white

PVC coated straining wires at 300mm centres. m2 1878

80mm Thick "Lambdaboard" or equivalent and approved insulation board, fixed in accordance

with the manufacturer's recommendations

14

Insulation laid taut over purlins and fixed concurrent with battens, purlins, etc including white

PVC coated straining wires at 383mm centres. m2 1079

C2.2 Bills of Quantities

Elandsfontein/Isando 38 of 96

Page 39: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SHEET METAL FLASHINGS, LININGS, COPING, ETC.

0,6mm Galvanized sheet iron with embossed baked enamel finish on one side

15

Copings with riveted and soldered joints attached with suitable clips at 500mm centres along

both edges, riveted to coping and plugged to brickwork or concrete m2 50

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 7

CARPENTRY AND JOINERY

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Particle board:

Particle board shall comply with the following specifications: a) SABS 1300 Particle board:

exterior and flooring type b) SABS 1301 Particle board: interior type

Joinery:

Descriptions of frames shall be deemed to include frames, transoms, mullions, rails, etc

Descriptions of hardwood joinery shall be deemed to include pelleting of bolt holes

Prior proceeding with the production of the joinery fittings of the Library fit-out, the contractor

needs to present one (1) sample shelving unit for approval by the Principal Agent

Timber Types:

Hardwood and Softwood All hardwood shall be deemed te be Meranti. All softwood shall be

deemed to be South African Pine

Fixing:

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or shot pins

to brickwork or concrete

Fittings are to be bolted to walls to architect's approval

Sizes:

The Contractor shall make allowance in his prices for minor variances in stated finished sizes

of timber doors, door members, door frames, architraves, etc, which are to match existing

The specified sizes of wrought timbers are the net finished sized as required and the

Contractor is to make such allowance for wrought faces as he deems necessary

Decorative laminate finish:

Laminate finish shall be glued under pressure. Edge strips shall be butt jointed at junctions

with adjacent similar finish

C2.2 Bills of Quantities

Elandsfontein/Isando 39 of 96

Page 40: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

EAVES, VERGES, ETC

"Nutec" or similar approved pressed fibre cement

1

350 x 12mm medium density plain ungrooved Fascias and barge boards fixed with

countersunk brass screws including galvanised steel H-profile jointing strips m 250

SKIRTINGS

Wrought softwood

2 70 x 19mm Supawood skirting fixed 10mm above finished floor level to create shadowline m 95

DOORS ETC

Wrought hardwood meranti doors

3 40mm Single door 813 x 2332mm high (Type D01) No 3

4 40mm Single door 813 x 2332mm high (Type D03) No 4

5 40mm Single door 813 x 2332mm high (Type D10) No 2

6 40mm Single door 813 x 2332mm high (Type D11) No 1

7 40mm Single door 813 x 2057mm high (Type D12) No 4

8 40mm Double door 1626 x 2330mm high with flush meeting edges (Type D04) No 3

9 40mm Double door 1626 x 2330mm high with flush meeting edges (Type D07) No 1

10 40mm Double door 1626 x 2055mm high with flush meeting edges (type D08) No 2

11 Extra over doors for cut-out for 400 x 100mm high louvre (louvre elsewhere measured) No 3

12 Extra over doors for cut-out for 520 x 200mm high louvre (louvre elsewhere measured) No 8

13 Extra over doors for cut-out for 700 x 500mm high louvre (louvre elsewhere measured) No 2

Hollow core flush doors with commercial veneer

14 40mm Door 762 x 2032mm high (Type D06) No 15

Semi-solid flush doors with commercial veneer

15 40mm Single door 813 x 2100mm high (Type D02) No 10

"Bitcon Industries" or equivalent and approved fire doors with commercial veneer

16 40mm Class B door 813 x 2,032mm high including frame for one brick wall No 1

FITTINGS

SUPPLEMENTARY PREAMBLES

Particle board

Particle board shall comply with the following specifications:

a) SANS 1931

b) SANS 50312/EN312

C2.2 Bills of Quantities

Elandsfontein/Isando 40 of 96

Page 41: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Joinery

Descriptions of frames shall be deemed to include frames, transomes, mullions, rails, etc

Descriptions of hardwoord joinery shall be deemed to include pelleting of bolt holes

Fixing

All items to be plugged to brick/concrete walls inless stated otherwise

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or shot pins

to brickwork or concrete

Decorative laminate finish

Laminate finish shall be glued under pressure. Edge strips shall be butt jointed at junctions

with adjacent similar finish

Panelling

The descriptions of panelling shall be deemed to include all components, assembling, housing,

notching, glueing, blocking, screwing with cuntersunk screws, cleats, edge strips, routing lines,

skirtings, cornices, metalwork, duco spray painting, sealant, staining, paint or varnish finishes,

etc

General

The references given in the descriptions are to the respective types of fittings detailed on the

architect's drawings attached to this bill for tender purposes

The fittings have been measured as complete units i.e the components of the units have not

been separately measured. The descriptions, therefore, of such units shall be deemed to

include all components, assembling, housing, notching, glueing, blocking, screwing with

countersunk screws, edge strips, expansion joints, insulation, decorative plastic finish, glass,

ironmongery, upholstered cushions, metalwork, duco spray painting, sealant, staining, paint or

varnish finishes, etc

Fridges, hydro boils, coffee machines, plate warmers, electrical connections, power outlet

isolators, plumbing and drainage, fire equipment, tiled skirting and drywall partitions are by

others

Rates to include for procurement, workshop drawings where required, fabrication with welding

as indicated on drawings, delivery and erection on site complete

Copies of shop drawings, samples and mock-ups shall be submitted to the principal agent for

approval prior to commencement of the works

C2.2 Bills of Quantities

Elandsfontein/Isando 41 of 96

Page 42: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Kitchen cupboards, etc

Kitchen cupboards and counter tops as per architect's specification with white

melamine carcass, including 20mm thick Rustenburg granite worktop with hole for

sanitary fittings and 16mm thick 'Havard cherry' melamine particle board panels,

including all subframes, supports, skirtings, ironmongery, etc (sink provided for

elsewhere)

Floor units

17

Floor cupboard, 1,432mm long x 650mm deep x 900mm high overall, as per architect's

drawings with counter top, sides, bottom, divisions, shelf, back, doors, dividing framework and

drawers No 1

-Drawing 0372607C - 403 - Multi-purpose and Dining room

18

Floor cupboard, 3,129mm long x 600mm deep x 900mm high overall, as per architect's

drawings with counter top, sides, bottom, divisions, shelf, back, doors, dividing framework and

drawers No 1

-Drawing 0372607C - 401 - Staff room

19

Floor cupboard, 8,979mm long x 600mm deep x 900mm high overall, as per architect's

drawings with counter top, sides, bottom, divisions, shelf, back, doors, dividing framework and

drawers No 1

-Drawing 0372607C - 403 - Multi-purpose and Dining room

Laundry cupboards as per architect's specification with white melamine carcass and

16mm thick 'White' melamine particle board panels, including all subframes, supports,

skirtings, ironmongery, etc

Floor units

20

Floor cupboard, 1,100mm long x 600mm deep x 760mm high overall, as per architect's

drawings with sides, bottom, divisions, shelf, back, doors, dividing framework and drawers

(counter top measured elsewhere) No 1

-Drawing 0372607C - 401 - Laundry room

Tall units

21

Tall cupboard, 1,800mm high x 600mm deep x 550mm wide, as per architect's drawing with

sides, bottom, divisions, shelf,back, doors and dividing framework No 2

Drawing 0372607C - 401 - Laundry room

Counter tops, etc

Rustenburg granite worktop with 100mm high granite skirting, with bevelled edge

finish, concealed fixed through steel angle frames, frames to be painted Plascon GR-

NO2, colour: Black, as per architect's specification and drawings

22 Counter top, 1,800mm long x 600mm deep x 20mm thick overall, as per architect's drawing No 1

- Drawing 0372607C-402 - Guardhouse

23 Counter top, 6,185mm long x 600mm deep x 20mm thick overall, as per architect's drawing No 1

- Drawing 0372607C-402 - Guardhouse

Rustenburg granite worktop with 100mm high granite skirting, with bevelled edge

finish, concealed fixed through steel angle frames, frames to be painted Plascon GR-

NO2, colour: Black, including brushed aluminium support frames, as per architect's

specification and drawings

24 Counter top, 7,732mm long x 600mm deep x 20mm thick overall, as per architect's drawing No 1

- Drawing 0372607C-401 - Laundry room

25

Counter top, 8,170mm long x 750mm deep on one side and 950mm deep on other side x

20mm thick overall, as per architect's drawing No 1

- Drawing 0372607C-402 - Watch room

C2.2 Bills of Quantities

Elandsfontein/Isando 42 of 96

Page 43: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Shelving, etc

Shelving as per architect's specification with 16mm thick 'White' melamine particle

board panels, steel shelf brackets with white epoxy powder coated finish equally

spaced at 900mm max, including all subframes, supports, bolts, etc

26 Shelving, 4,912mm wide x 1,040mm high overall, as per architect's drawing No 1

- Drawing 0372607C-401 - Laundry room

GENERAL ALLOWANCE

Office furniture

27

Allow the budgetary amount of R315,000 (Three Hundred and Fifteen Thousand Rand) for

office furniture Item 1 R 315 000.00

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 8

CEILING, PARTITIONS AND ACCESS FLOORING

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Descriptions:

Items described as "nailed" shall be deemed to be fixed with hardened steel nails or pins or

shot pinned to brickwork or concrete

Items described as "plugged" shall be deemed to include screwing to fibre, plastic or metal

plugs at not exceeding 600mm centres, and where described as "bolted" the bolts have been

given elsewhere

Bulkheads

Bulkheads are those areas of the ceiling which are at a level differing from the general ceiling

in a particular room or area and which generally occur along the perimeter of the room or area.

Their purpose is either to conceal services or to create an architectural feature by changing

levels.

Bulkheads will only be measured as such when they conform with the above description and

when the horizontal or vertical dimensions do not exceed 1,2m. Should these dimensions be

more than 1,2m then the horizontal or vertical ceilings will be included in the general ceiling

measurements.

INSULATION

Approved type mineral wool ceiling insulation in blanket form laid in single thickness

1 140mm Insulation nailed to underside of ceilings m2 861

C2.2 Bills of Quantities

Elandsfontein/Isando 43 of 96

Page 44: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

CEILINGS ETC

NAILED UP CEILINGS

6,4mm Thick "Rhino" or equivalent and approved gypsum plasterboard ceiling with 63mm wide

strips of mesh scrim nailed over joints and the whole finished with 6mm thick gypsum skim

plaster to a smooth polished surface as per the manufacturers specification

2 Ceilings including 38 x 38 mm sawn softwood brandering fixed to steel at 400 mm centres m2 175

80mm Thick "Lambdaboard" or equivalent as ceiling laid over purlins, fixed in accordance with

the manufacturer's recommendations

3

Insulation laid taut over purlins and fixed concurrent with battens, purlins, etc including white

PVC coated straining wires at 383mm centres. m2 10

"Rhino" gypsum plasterboard cornices

4 75mm Coved cornices m 105

Sundries

5 Extra over ceiling for opening for 1 700 x 1 200mm No 5

6 Extra over ceiling for opening for 550 x 4 000mm No 15

SUSPENDED CEILINGS

Pre-painted 1200 x 600 x 9mm "Lafarge gypsum" or equivalent and approved acoustic lay-in

ceilings on "Donn" pre-painted exposed tee suspension system including main and cross

tees, necessary hangers, grids, etc

7 Ceilings suspended not exceeding 1m below steel trusses and concrete soffits m2 979

Pre-painted 1200 x 600 x 9mm "Lafarge gypsum" or equivalent and approved vinyl faced lay-in

ceilings on "Donn" pre-painted exposed tee suspension system including main and cross tees,

necessary hangers, grids, etc

8 Ceilings suspended not exceeding 1m below steel trusses and concrete soffits m2 56

Cornices, perimeter trims, etc to suspended ceilings

9 Standard 25mm aluminium "Shadow Line" or similar approved cornice m 920

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 9

FLOOR COVERINGS, WALL LININGS, ETC

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

C2.2 Bills of Quantities

Elandsfontein/Isando 44 of 96

Page 45: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

FLOOR COVERINGS

600 x 600mm x 7mm "Avance 07" or equivalent and approved use class 5 heavy commercial

bitumen backed tufted loop pile carpet tiles

1 On floors m2 262

500 x 500 x 6,5mm Thick "Plasti-for" or equivalent and approved interlocking heavy duty tiles

with medallion textures and hidden interlocking joints (Colour: Dark Grey)

2 On floors m2 59

SUNDRIES

3 Making good defects in power floated concrete floors with "Pavelite" to receive vinyl tiles m2 321

Total Carried Forward To Section Summary

SECTION No 2

BILL No 10

IRONMONGERY

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Finishes to ironmongery

Where applicable finishes to ironmongery are indicated by suffixes in accordance with the

following list: BS Satin bronze lacquered CH Chromium plated SC Satin chromium plated SE

Silver enamelled GE Grey enamelled AS Anodised silver AB Anodised bronze AG Anodised

gold ABL Anodised black PB Polished brass PL Polished and lacquered PT Epoxy coated SD

Sanded

Fixing

Unless otherwise described all ironmongery shall be deemed to be fixed to soft- or hardwood

All ironmongery items referenced to trade names or similar approved must be manufactured

and fixed in strict accordance with the manufacturers specification and fixing detail

C2.2 Bills of Quantities

Elandsfontein/Isando 45 of 96

Page 46: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

HINGES, FLOOR SPRING HINGES, BOLTS, PANIC BOLTS, ETC

"Dorma" or equivalent and approved

1

PHA2/S Two point locking panic bar - Single door - door leaf 1000 x 2270mm high

(2201.2104.PHX02.PHX04) Sets 2

2 DFB-SC-180 153mm Satin chrome flush bolt with heel No 5

3 DFB-SC-181 305mm Satin chrome flush bolt with heel No 5

4 DPS-SS-032 dust proof strike No 8

LOCKS

The following locks are to be suitable for master and grand master key operation

"Dorma" or equivalent and approved

5 D032D stainless steel bathroom/WC deadlock No 16

6 781402352 Iseo 35mm stainless steel narrow stile hook lock No 5

7 D07635 35mm Stainless steel narrow stile heavy duty swivel sash lock No 12

8 D07735 35mm Stainless steel narrow stile heavy duty swivel deadlock No 1

9 D036S stainless steel euro profile cylinder sash lock No 18

10 D037D stainless steel euro profile cylinder dead lock No 8

11 D038R Nickel Plated rebate conversion kit for D036/D037 No 5

12 DPL1000MK Satin Nickel 50mm Padlock - master keyed No 3

CYLINDERS

"Dorma " or equivalent and approved

13 DDC106601MK Nickel plated 66mm ten pin euro profile master keyed double cylinder No 36

14 DSC104301MK Nickel plated 43mm five pin euro profile master keyed single cylinder No 10

15 DCE-105 stainless steel narrow stile cylinder escutcheon Pairs 6

HANDLES

"Dorma" or equivalent and approved

16 CR001 Stainless steel lever handle on rose with cylinder escutcheons Pairs 18

17 PHT3901 Exterior access lock with lever handle (cylinder not included) No 2

18 DFP-SS-026 102 x 50mm Stainless steel rectangular flush pull handle No 10

19

"DPH215 BTB 382 x 32mm stainless steel "D" shaped offset tubular back-to-back pull handle

(BTB fixing sets included) Pairs 2

20

DPH301B 325 x 25mm stainless steel D shaped straight tubular back-to-back pull handle with

flange fixing (BTB fixing sets included) Sets 2

21 TH120 N/S stainless steel lever handles on rose with N/S Cylinder escutcheons Sets 12

"Dorma" or equivalent and approved

22 DWC-006 stainless steel WC indicator with 79mm turn knob for physically impaired Pairs 16

C2.2 Bills of Quantities

Elandsfontein/Isando 46 of 96

Page 47: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

PUSH PLATES AND KICK PLATES

"Dorma" or equivalent and approved

23

DPP-SS-CL 150X300 150x 300 x 1,2mm Thick stainless steel push plate with cylinder hole

punched left hand side No 4

24

DPP-SS-CR 150X300 150x 300 x 1,2mm Thick stainless steel push plate with cylinder hole

punched right hand side No 4

25 DPP-SS-BL 170X75 170 x 75 x 1,2mm Thick brushed stainless steel blank push plates No 15

26 DHP-SS-BL 75X170 DPH 301 Pull handle on 75x 170x 1,2mm stainless steel plate (no cut out) No 15

27

DHP-SS-BL 150X300 DPH 301C Pull handle on 150x 300x 1,2mm brushed stainless steel

plate (no cut out) No 8

28 DKP-SS-200 Stainless steel door width kickplate, width x 200 x 1,2mm thick No 22

DOOR CLOSERS, ETC

"Dorma" or equivalent and approved

29

BTS75 SAA-NHO Single S.S action non hold open floor spring for aluminium doors with no

stainless steel cover plate/caps (Mech/Spindle/7510SS/7411K/56E) Sets 2

30

TS91B EN 3 Cam action slide channel non-hold open door closer - Hydraulic speed control;

Push side - transom fixing; Pull side - leaf fixing (Silver) No 8

31

TS92G EN 2-4 Cam action slide channel non-hold open door closer - Adjustable length,

Hydraulic speed control; Pull side - transom fixing; Push side - leaf fixing (Silver) No 2

32

TS73V PA EN 2-4 Parallel arm door closer with delayed action - push side - fixing (soffit

bracket included) (Silver) No 1

LETTERS, NAMEPLATES, ETC FIXED IN POSITION COMPLETE

"Dorma" or equivalent and approved

33 DSS-130 "MALE" pictogram sign on 150 x 150mm stainless steel plate No 4

34 DSS-131 "FEMALE" pictogram sign on 150 x 150mm stainless steel plate No 4

35 DSS-133 "DISABLED PERSONS" pictogram sign on 150 x 150mm stainless steel plate No 1

BATHROOM FITTINGS

36

32mm granite counter top with 25mm bullnose edge and 150mm high granite splash back

sealed flush to granite counter. Counter to have fixed timber piece to sides as per detail. m 12

37

Servest hygiene solar hot air hand dryer "code DIS-STAIN-060" or equivalent and approved,

plugged and screwed to wall with stainless steel screws No 1

38 "Franke STRX210" or equivalent and approved, touch free electronic warm air hand dryer No 4

39

"Servest hygiene ocean DIS-TIDYR-003" or equivalent and approved toilet roll holder for five

rolls, 102 x 508 x 103mm deep, plugged and screwed to wall with stainless steel screws No 16

40

"Servest hygiene solar DIS-STAIN-071" or equivalent and approved wall mounted soap

dispenser, foam or spray, 330 x 394 x 229mm deep, plugged and screwed to wall with

stainless steel screws No 20

41

"Servest hygiene solar ocean simplicity DIS-LUNAD-050" or equivalent and approved wall

mounted towel dispenser size 338 x 479 x 149mm No 6

C2.2 Bills of Quantities

Elandsfontein/Isando 47 of 96

Page 48: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

42

"Cobra Watertech AC-0901-100" or equivalent and approved, collette chrome plated towel rail,

590 x 60mm wide, plugged and screwed to wall No 4

43

"Cobra Watertech" or equivalent and approved, collette chrome plated robe hook (code: AC-

0907-100), 89 x 57mm wide, plugged and screwed to wall No 10

44

"Alisea hotel perfection 030516" or equivalent and approved, brass swivel towel rail with

chrome plated finish, 425 x 86 x 60mm deep, plugged and screwed to wall with stainless steel

screws concealed with chrome plated cover plates No 3

45

"Servest Hygiene DIS-BINNS-005 oceans femme" or equivalent and approved female sanitary

bin No 10

46

"Servest hygiene solar DIS-STAIN-121" or equivalent and approved wall mounted waste bin

large, plugged and screwed to wall with stainless steel screws No 6

47

"Chairman Industries SR2A" or equivalent and approved 32mm diameter stainless cistern back

rail No 1

48 "Chairman Industries DL2" or equivalent and approved stainless steel side grab rail No 1

49 "Genesis 706" or equivalent and approved stainless steel shelf, 400 x 111mm deep No 8

SUNDRIES

"Dorma" or equivalent and approved

50 DDH-SS-020 SS wall buffer plugged to brickwork or concrete No 6

51 DHC-SS-031B Stainless steel hat and coat hook with rubber buffer No 15

52 DDS-NP-018 Nickel plated floor door stop plugged to concrete No 48

BUILT-IN BRAAI

"Jetmaster 1200 Standard" or equivalent and approved built-in braai place complete with

outerbox, light fitting, potjie hook, charcoal starter and dispenser, charcoal tray, nickel plated

grille and door complete with and including flue, rotating cawl, etc

53 1275 x 530 x 1180mm High built-in braai No 1

STEEL LOCKERS

"Greenfield" or equivalent and approved steel lockers with standard baked enamel finish

complete with 25mm chromed metal hagrail with hinged bottom and top door with ventilation

louvres and locking mechanism and handle

54 Steel locker 450 x 300 x 1950mm high No 62

GENERAL ALLOWANCE

Gym equipment

55

Allow the budgetary amount of R1,400,000.00 (One Million and Four Hundred Thousand

Rand) for gym equipment Item 1 R 1 400 000.00

Building Signage

56

Allow the budgetary amount of R70,000.00 (Seventy Thousand Rand) for building signage to

be instructed by the Principal Agent Item 1 R 70 000.00

Total Carried Forward To Section Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 48 of 96

Page 49: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION No. 2

BILL No. 11

STRUCTURAL STEELWORK

NOTE

The Tenderer is advised to refer to the Trade Preambles before pricing these bills of quantities

SUPPLEMENTARY PREAMBLES

Descriptions

Descriptions of bolts shall be deemed to include nuts and washers

Descriptions of L-shaped and U-shaped anchor bolts shall be deemed to include bending,

threading, nuts and washers and embedding in concrete

Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed

to include nuts, washers and mortices in brickwork or concrete

Steelwork described as 'galvanised' shall be galvanised by means of the hot-dip process after

fabrication. Where welding on site is unavoidable, such welded joints shall be cleaned down

and cold galvanised to approval

Rates to include for procurement, three (3) copies of workshop drawings where required,

fabrication with welding as indicated on drawings, holes, wire brushing, delivery and erection

on site complete Correction of shop drawings shall not constitute a change in scope of work

unless the contractor notifies the principal agent in writing within seven (7) calender days and

shall not proceed with fabrication until so authorised by the principal agent

STEEL COLUMNS AND BEAMS

Welded columns in single lengths with flat section bearer and connection plates bolted to

concrete columns and beams

1 203 x 203 x 46kg/m H-section columns t 9.42

Welded beams in single lengths with flat section bearer and connection plates bolted to

concrete columns and beams

2 203 x 133 x 25kg/m I-section beams t 0.8

3 254 x 146 x 31kg/m I-section beams t 0.2

4 356 x 171 x 57kg/m I-section beams t 0.97

5 IPE 200 profile rafters t 0.27

6 300 x 100mm PFC profile t 2.84

7 195 x 195 x 6mm Square hollow sections t 0.15

C2.2 Bills of Quantities

Elandsfontein/Isando 49 of 96

Page 50: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Bolts to columns, beams, etc

8 High tensile bolts (class 8.8) t 1.47

9

Anchor assembly consisting if four (4 No) M16 straight threaded anchor bolts each 350mm

long with welded 70 x 70 x 10mm plate, caged together with two 50 x 5mm flat sections,

400mm girth each No 30

10 M16 x 220mm cast-in hold down bolts No 8

11 "Hilti" HVU/HAS M16 x 220mm chemical anchor and bolt No 18

STEEL GIRDERS, TRUSSES ETC

Welded portal frames with flat section bearer, gusset and connection plates and L-section

cleats bolted to concrete

12

10 (No) Single pitched portal frames of 406 x 178 x 54kg/m I-section rafters and 203 x 203 x

46kg/m columns, the truss 28 000mm long x approximately 3400mm high extreme and

columns 2293mm high, including tapered ends to rafters t 32.17

Welded roof trusses of angle section rails, struts, braces, cleats, etc and flat section bearer,

gusset and connection plates bolted to steel

13 1 (No) mono pitched lattice trusses 6100mm long x 2145mm high extreme (truss T3) t 0.29

14 4 (No) Mono pitched lattice trusses 7221mm long x 812mm high extreme (truss T8) t 1.02

15 1 (No) mono pitched lattice trusses 7343mm long x 1100mm high extreme (truss T6) t 0.28

16 2 (No) Mono pitched lattice trusses 8794mm long x 1350mm high extreme (truss T4a) t 0.73

17 2 (No) mono pitched lattice trusses 9707mm long x 885mm high extreme (truss T9) t 0.59

18 5 (No) Mono pitched lattice trusses 11114mm long x 1725mm high extreme (truss T7) t 2.23

19 3 (No) mono pitched lattice trusses 11193mm long x 1350mm high extreme (truss T5) t 1.33

20 2 (No) Mono pitched lattice trusses 11231mm long x 1200mm high extreme (truss T4) t 0.87

21 3 (No) mono pitched lattice trusses 11500mm long x 1350mm high extreme (truss T5a) t 1.37

22 4 (No) mono pitched lattice trusses 15932mm long x 2145mm high extreme (truss T2) t 2.47

23 1 (No) mono pitched lattice trusses 15932mm long x 2145mm high extreme (truss T2a) t 0.55

24 3 (No) mono pitched lattice trusses 16142mm long x 2586mm high extreme (truss T12) t 2.05

25 3 (No) Mono pitched lattice trusses 17254mm long x 2144mm high extreme (truss T1) t 2

Bolts to trusses, etc

26 High tensile bolts (class 8.8) t 4.8

27 "Hilti" HVU/HAS M16 x 220mm chemical anchor and bolt No 130

C2.2 Bills of Quantities

Elandsfontein/Isando 50 of 96

Page 51: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

PURLINS, GIRTS, BRACING, TRIMMERS, RAFTERS, ETC

Trimmers and welded rafters

28 70 x 70 x 6mm rafters t 2.03

Pre-galvanised purlins and girts bolted to steel

29 100 x 75 x 20 x 2,5mm Cold formed lipped channel girts t 1.48

30 150 x 50 x 20 x 2,0mm Cold formed lipped channel girts t 1.06

31 150 x 75 x 20 x 3,0mm Cold formed lipped channel girts t 1.62

32 75 x 50 x 20 x 3,0mm Cold formed lipped channel purlins t 0.17

33 100 x 75 x 20 x 2,5mm Cold formed lipped channel purlins t 4.5

34 100 x 75 x 20 x 3,0mm Cold formed lipped channel purlins t 0.2

35 125 x 75 x 20 x 3,0mm Cold formed lipped channel purlins t 0.23

36 150 x 50 x 20 x 3,0mm Cold formed lipped channel purlins t 0.81

37 150 x 75 x 20 x 3,0mm Cold formed lipped channel purlins t 5.23

38 200 x 100 x 20 x 3,0mm Cold formed lipped channel purlins t 0.33

39 250 x 100 x 20 x 3,0mm Cold formed lipped channel purlins t 0.36

40 300 x 100 x 20 x 3,0mm Cold formed lipped channel purlins t 0.4

Welded bracing etc with flat section connection plates bolted to steel

41 Angle anti-sag rails t 1.29

42 Angle bracing, etc t 1.2

43 Round sag rods with threaded ends t 0.2

Bolts to purlins, girts, bracing, etc

44 High tensile bolts (class 4.8) t 2.11

PAINTING

Prepare and apply one coat red-oxide primer

On structural steel (workshop application) t 92.11

Prepare and apply one coat universal undercoat and two coats polyurethane paint on steel

45 On structural steel (site application) t 92.11

Total Carried Forward To Section Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 51 of 96

Page 52: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION No. 2

BILL No. 12

METALWORK

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Descriptions

Descriptions of bolts shall be deemed to include nuts and washers Descriptions of expansion

anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers

and mortices in brickwork or concrete Metalwork described as "holed for bolt(s)" shall be

deemed to exclude the bolts unless otherwise described

Sealing frames of doors and windows

Descriptions of metal doors and windows shall be deemed to include sealing at junctions

between frames and walls, sills, etc all around with a continuous fillet of an approved clear

silicone sealant on both sides

Shop drawings, samples and mock-ups

Rates to include for procurement, three (3) copies of workshop drawings where required,

fabrication with welding as indicated on drawings, holes, wire brushing, delivery and erection

on site complete Correction of shop drawings shall not constitute a change in scope of work

unless the contractor notifies the principal agent in writing within seven (7) calender days and

shall not proceed with fabrication until so authorised by the principal agent

STAINLESS STEEL HANDRAILS, BALUSTRADES, ETC

Supplementary Preambles

Rates for balustrades and handrails are deemed to include for all closure ends, intersections,

mitred intersections, ramps, knees, etc as will be required

Welded handrails to stairs

1

60mm Diameter continuous horizontal stainless steel handrails, 1000mm high overall, fixed

with and including 15mm diameter stainless steel rods at 600mm centres fixed to wall with

40mm diameter stainless steel spon cups to conceal fix plate, including all flat section plates,

cleats, etc m 8

2

60mm Diameter continuous raking stainless steel handrails, 1000mm high overall, fixed with

and including 15mm diameter stainless steel rods at 600mm centres fixed to wall with 40mm

diameter stainless steel spon cups to conceal fix plate, including all flat section plates, cleats,

etc m 7

3 Extra over for flat closed end No 2

4 Extra over for ramp or knee No 4

5 Extra over for mitred L-section No 4

GALVANISED STEEL BALUSTRADES

Supplementary Preambles

Rates for balustrades and handrails are deemed to include for all closure ends, intersections,

mitred intersections, ramps, knees, etc as will be required

C2.2 Bills of Quantities

Elandsfontein/Isando 52 of 96

Page 53: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Welded balustrading to balconies

6

Balustrading to balconies 600mm high of 60mm diameter continuous horizontal handrail,

including 4 No 12mm diameter mild steel rods welded horizontally at 100mm centres on and

including 2 No 8 x 45mm flat section posts at varying centres each with 150 x 30 x 5mm flat

section base plate bolted to concrete with and including M8 chemical anchor bolts m 25

7 Extra over for flat closed end No 4

8 Extra over for mitred L-intersection No 4

SUNDRY GALVANISED STEELWORK

Welded bearers to non-load bearing brickwork

9 100 x 18mm Thick stiffener plates kg 814

10 200 x 10mm Thick stiffener plates kg 3179

11 8mm Diameter high tensile steel reinforcing bar welded to plate kg 184

12 150 x 100 x 18mm Flat section plates kg 38

13 200 x 150 x 12mm Flat section plates kg 127

14

M12 "Hilti" HVU/HAS chemical anchors, welded to plate and cast into concrete slab, all in

accordance with manufacturers recommendations No 252

Welded bearers to load-bearing brickwork

15 10mm Diameter stud, 100mm long, welded to plate and cast into ring beam No 180

16

M8 concrete anchor, welded to plate and cast into concrete slab, all in accordance with

manufacturers recommendations No 180

17 20mm Diameter high tensile steel reinforcing bar welded to plate kg 311

18 Fishtail anchors No 720

19 120 x 30 x 10mm Flat section plates kg 57

20 Slip joint, 230mm wide m 270

BURGLAR BARS

10mm Solid square Spanish type "Code B2" or equivalent and approved mild steel burglar

bars, colour black, bolted to frames at opening sections at 150mm centres fixed to walls

21 Steel burglar bars to pattern m2 79

PRESSED STEEL TRANSFORMER ROOM DOORS AND FRAMES

"Durowin" or equivalent and approved

22

Type D.V. steel transformer room door size 1,829 x 2,438mm high with 240 x 1630mm high

door grille to suit one brick wall No 3

ALUMINIUM WINDOWS, DOORS, LOUVRES, ETC

Supplementary Preambles

Tenderers are referred to architect's drawings accompanying these bills of quantities for tender

purposes All dimensions to be confirmed on site prior to manufacturing

Copies of design and shop drawings, samples and mock-ups shall be submitted to the

principal agent for approval prior to commencement of the works

C2.2 Bills of Quantities

Elandsfontein/Isando 53 of 96

Page 54: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Aluminium windows, etc., are to be constructed and installed in accordance with the guidelines

of The Association of Architectural Aluminium Manufactures of South Africa (AAAMSA). Unless

otherwise stated ironmongery is to be the manufacturer's standard

Glazing shall comply with SAGGA regulations. Glass shall be toughened glass as described in

the bills of quantities. Glass thickness shall comply with SAGGA regulations irrespective of the

thickness referred to in the schedules/drawings

Doors and windows shall be supplied with protective tape and plastic which shall be removed

only once surrounding trades have been completed

Ironmongery for windows, doors and shopfronts, including hinges, friction stays, handles, flush

bolts, etc shall be included in the rate of the specific item and shall be installed as part of that

item Ironmongery such as locks, door handles, door closers, etc shall form part of the

Ironmongery bill elsewhere in these bills of quantities

The following certificates shall be provided prior to commencement of the works on site: 1. A

copy of the relevant AAAMSA Performance Test Certificate from the manufacturer/contractor

supplying the architectural aluminium product 2. A certificate of Conformance confirming that

anodising or powder coating has been processed in accordance with SANS 999 and 1796

respectively 3. A powder guarantee of not less than 15 years issued by the powder

manufacturer. The specific condition contained in this guarantee shall form part of the powder

coating process 4. A certificate of Conformance confirming that glazing has been installed in

accordance with SANS 0137, ensuring that safety glazing material have been installed in

mandatory areas and that each individual pane of safety glazing materials has been

permanently marked 5. A warranty from the manufacturer of the laminated safety glass and or

hermetically sealed glazing units guaranteeing products against delamination and colour

degradation for a period of not less than five years

SHOPFRONTS, CURTAIN WALLS, ETC

"Wispeco" or equivalent and approved powder coated aluminium shopfront (colour Matt

Charcoal ANP 3055) with and including all channels, sills, mullions, gaskets, etc with 6mm Low

E laminated safety glass as per SANS 1400 Part N, all to specification and plugged to

brickwork or concrete

23 Purpose made shopfront size 1200 x 2400mm high overall (type SF06) No 7

24 Purpose made shopfront size 1310 x 1940mm high overall (type SF16) No 4

25 Purpose made shopfront size 1310 x 5225mm high overall (type SF15) No 8

26 Purpose made shopfront size 1480 x 1126mm high overall (type SF13) No 2

27

Purpose made shopfront size 2000 x 2400mm high overall with one single door, 975 x

2400mm high (type SF12) No 4

28 Purpose made shopfront size 2000 x 1900mm high overall (type SF09) No 1

29

Purpose made shopfront size 3000 x 2400mm high overall with one double door, 1425 x

2400mm high (type SF08) No 2

30

Purpose made shopfront size 3940 x 2400mm high overall with one single door, 975 x

2400mm high (type SF04) No 3

31

Purpose made shopfront size 4490 x 2400mm high overall with one double sliding door, 1750

x 2400mm high (type SF03) No 2

32 Purpose made shopfront size 4855 x 1615mm high overall, with one side sloping (type SF02) No 1

33

Purpose made shopfront size 4855 x 2400mm high overall with one double door, 1750 x

2400mm high (type SF01) No 1

34 Purpose made shopfront size 5365 x 1126mm high overall (type SF14) No 1

C2.2 Bills of Quantities

Elandsfontein/Isando 54 of 96

Page 55: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

35

Purpose made shopfront consisting of two fixed side panels, each 1045 x 2400mm high (type

SF06) and one single door, 1200 x 2400mm high (type SF07) No 1

36

Purpose made shopfront consisting of two fixed side panels, one 1045 x 2400mm high (type

SF06) and the other 2940 x 2400mm high (SF05), and one single door, 1200 x 2400mm high

(type SF07) No 1

37

Purpose made shopfront consisting of three fixed panels, one panel 2860 x 1126mm high

(type SF11) and two side panels 1330 x 1126mm high (type SF10) No 1

38

Purpose made shopfront consisting of four fixed side panels, each 1045 x 2400mm high (type

SF06) and one single door, 1200 x 2400mm high (type SF07) No 1

WINDOWS

"Wispeco" or equivalent and approved powder coated aluminium window (colour Matt

Charcoal ANP 3055) with 6mm Low E laminated safety glass as per SANS 1400 Part N, all to

specification and plugged to brickwork or concrete

39 Fixed pane clerestory windows size 1400 x 600mm high (type W05) No 4

40

Window size 600 x 1200mm high overall with 600 x 600mm high top hung opening window

section (type W02) No 21

41

Window size 1500 x 1200mm high overall with 1500 x 600mm high top hung opening window

section (type W04) No 6

42

Window size 1500 x 1800mm high overall with two 1500 x 600mm high top hung opening

window sections (type W01) No 17

43

Window size 2800 x 600mm high overall with four 700 x 600mm high top hung opening

window sections (type W06) No 4

DOORS

"Wispeco" or equivalent and approved powder coated aluminium doors (colour Matt Charcoal

ANP 3055) with 6mm Low E laminated safety glass as per SANS 1400 Part N, all to

specification and plugged to brickwork or concrete

44 3000 x 2100mm high Sliding double door and frame (type D05) No 4

DOOR FRAMES

"Wispeco" or equivalent and approved powder coated aluminium door frames (colour Matt

Charcoal ANP 3055), all to specification and plugged to brickwork or concrete

45 Frame for door 898 x 2100mm high (type D06) No 15

46 Frame for door 949 x 2125mm high (type D02, D12) No 15

47 Frame for door 949 x 2400mm high (type D01, D03, D10) No 12

48 Frame for door 1036 x 2400mm high (type D11) No 1

49 Frame for double door 1766 x 2100mm high (type D08) No 2

50 Frame for double door 1766 x 2400mm high (type D04, D07) No 4

LOUVRES

Natural anodised aluminium louvre units fixed into timber doors

51 Louvre size 400 x 100mm high (type D10, D11) No 3

52 Louvre size 520 x 200mm high (type D08, D12) No 9

53 Louvre size 700 x 500mm high (type D07) No 2

C2.2 Bills of Quantities

Elandsfontein/Isando 55 of 96

Page 56: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

"Wispeco" or equivalent and approved powder coated aluminium extruded slat serving hatch

set in built-in galvanised steel shutter box (colour Matt Charcoal ANP 3055), all to specification

and plugged to brickwork or concrete

54 Serving hatch size 1400 x 1500mm high (type W03) No 1

"Wispeco" or equivalent and approved powder coated aluminium extruded slat attenuator vent

louvre set in built-in galvanised steel shutter box (colour Matt Charcoal ANP 3055), all to

specification and plugged to brickwork or concrete

55 Louvre size 1200 x 2400mm high (type W07) No 2

SHOWER CUBICLE DOORS

"Primador" or equivalent and approved white powder coated aluminium single pivot shower

door, glazed with GSA SmartGlass clear toughened safety glass all fixed complete to walls

including pointing all round both sides of frame, all in accordance with the architect's

specifications and manufacturer's recommendations

56 Shower door 900 x 1800mm high No 8

SECTIONAL OVERHEAD DOORS, ETC

PRESSED STEEL POWDER COATED SECTIONAL DOORS

"Coroma Coroview" or equivalent and approved vertical slider sectional overhead door, all as

per architect's specification and manufacturer's recommendations, bolted to steel (Colour: to

be confirmed)

57

Electrically operated vertical slider sectional door for 4451 x 5000mm high opening with 12 No

aluminium coronet panel inserts and 15 No glass panels inserts, each approximately 1361 x

491mm high, including electrical connection and commissioning (electrical isolator elsewhere)

(type ED) No 10

C2.2 Bills of Quantities

Elandsfontein/Isando 56 of 96

Page 57: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

WELDED SCREENS, GATES, ETC

Mild steel welded gates

58

Single gate 1176 x 1870mm high overall consisting of 50 x 50 x 3mm hollow section frame and

50 x 50 x 3mm hollow section horizontal middle rail filled in vertically with 20mm diameter solid

bars at 100mm centres and fitted with a pair of suitable pivot hinges and brackets with fish tail

lugs built into brick walls and including ears for padlock, etc complete (type G02) No 2

GENERAL ALLOWANCE

Carports

59

Allow the budgetary amount of R155,000.00 (One Hundred and Fifty-five Thousand Rand) for

carports Item 1 R 155 000.00

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 13

PLASTERING

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SCREEDS

Screed on concrete

1 30mm Thick on floors and landings m2 1075

2 30mm Thick on treads and risers m2 8

3 85mm Thick under steel columns m2 2

4 Average 35mm thick on floors to falls and currents m2 209

INTERNAL PLASTER

Cement plaster on brickwork to receive tiling, etc.

5 On walls m2 749

6 On narrow widths m2 25

Cement plaster on brickwork

7 On walls m2 2648

8 On narrow widths m2 89

Gypsum skim plaster on brickwork

9 On walls m2 2648

10 On narrow widths m2 89

One coat cement plaster on concrete

11 On walls m2 65

12 On isolated beams m2 147

C2.2 Bills of Quantities

Elandsfontein/Isando 57 of 96

Page 58: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

13 On soffits m2 161

EXTERNAL PLASTER

One coat cement plaster on brickwork

14 On walls m2 2025

15 On sloping top, edge and projecting soffit of sills 380mm girth m 45

16 On narrow widths m2 34

Skim finish plaster 5:1 on concrete

Smooth concrete slab to receive gyproc cretestone skim finish plaster

17 On concrete soffits and beams m2 473

18 On concrete columns m2 45

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 14

TILING

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

SUPPLEMENTARY PREAMBLES

Descriptions:

Unless described as "fixed with adhesive to plaster (plaster elsewhere measured)" descriptions

of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster

backing and descriptions of tiling on concrete floors, etc. shall be deemed to include 1:3 plaster

bedding

WALL TILING

Allow the prime cost amount of R150.00/mB2 for 300 x 300mm ceramic tiles fixed with

adhesive to plaster (plaster elsewhere) and flush pointed with tinted waterproof jointing

compound and add for taking delivery, temporary storage, unpacking, fixing in position, waste,

profit. etc

1 On walls m2 749

2 On walls in splashbacks m2 8

3 On projecting and isolated columns m2 44

4 On narrow widths m2 26

5 Fair exposed cutting and fitting around pipe not exceeding 100mm diameter No 54

FLOOR TILING (INDOOR AREAS)

Allow the prime cost amount of R250.00/m2 for 200 x 200mm porcelain floor tiles fixed with

adhesive to screeds (screed elsewhere) and flush pointed with tinted waterproof jointing

compound and add for taking delivery, temporary storage, unpacking, fixing in position, waste,

profit, etc

6 On floors and landings m2 425

7 On sills 115mm wide of cut tiles in stretcher course laid flat m 54

C2.2 Bills of Quantities

Elandsfontein/Isando 58 of 96

Page 59: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

8 On treads 270mm wide m 21

9 On risers 150mm high m 21

10 Skirting 75mm high m 408

11 Skirting 150mm high stepped over treads and risers of stairs m 17

Allow the prime cost amount of R350.00/m2 for 600 x 600mm porcelain floor tiles fixed with

adhesive to screed (screed elsewhere) and flush pointing with tinted waterproofing jointing

compound and add for taking delivery, temporary storage, unpacking, fixing in position, waste,

profit, etc

12 On floors and landings m2 368

13 Skirting 75mm high m 309

Allow the prime cost amount of R500/m2 for mosaics, fixed with adhesive to screed (screed

elsewhere) and flush pointed with tinted waterproof jointing compound and add for taking

delivery, temporary storage, unpacking, fixing in position, waste, profit, etc

14 On shower floors to falls m2 14

FLOOR TILING (OUTDOOR AREAS)

Allow the prime cost amount of R250.00/m2 for 200 x 200mm non-slip porcelain floor tiles fixed

with adhesive to screeds (screed elsewhere) and flush pointed with tinted waterproof jointing

compound and add for taking delivery, temporary storage, unpacking, fixing in position, waste,

profit, etc

15 On floors and landings m2 38

16 On risers 85mm high m 9

17 On copings 230mm wide of stretcher course tiles laid sloping m 9

CORNER PROTECTORS, DIVIDING STRIPS ETC.

Kirk Marketing or equivalent and approved trims etc. fixed to brickwork or concrete

18 ASE080 polished aluminium straight edge trim m 1170

19 PVC trim and edging (code 648) m 135

Total Carried Forward To Section Summary

SECTION No. 2

BILL No. 15

PLUMBING AND DRAINAGE (PROVISIONAL)

MODEL PREAMBLES FOR TRADES

For Preambles refer to "MODEL PREAMBLES FOR TRADES 2008". These "MODEL

PREAMBLES", published by the Association of South African Quantity Surveyors, are deemed

to be included in these Bills of Quantities and tenderers are to ensure that they are in

possession thereof.

C2.2 Bills of Quantities

Elandsfontein/Isando 59 of 96

Page 60: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SUPPLEMENTARY PREAMBLES

"Polycop" polypropylene pipes

Polypropylene pipes 54mm diameter and under shall be seamless copper coloured class 16

pipes jointed with "Fast-fuse" heat welded thermoplastic or brass compression fittings as

designed for use with copper pipes as stated.Pipes shall be firmly fixed to walls etc with

coloured nylon snap-in pipe clips with provision for accommodating thermal movement and

jointed and fixed strictly in accordance with the manufacturer's instructions. All pipe diameters

are nominal external.

"Polylink" polypropylene pipes

Polypropylene pipes 63mm diameter and over shall be class 12 pipes jointed with cast iron

"Supraclamp" running joints. Fusion welded bends, once or twice mitred as necessary, and

tees shall be factory manufactured.

Fusion welded bends and tees shall include jointing to pipes with PVC rubber ring double Z

joint couplers. Branch tees shall include flanged and bolted joints to "Polycop" branch pipes in

addition and for brass compression male iron to copper straight couplers.

Reducers shall include jointing to pipes with PVC rubber ring double Z joint couplers and

reducers shall be of sufficient overall length to accommodate same. All pipes shall be jointed

and fixed strictly in accordance with the manufacturer's instructions. All pipe diameters are

nominal external.

uPVC pipes and fittings

Sewer and drainage pipes and fittings shall be jointed and sealed with butyl rubber rings. Soil,

waste and vent pipes and fittings shall be solvent weld jointed.

uPVC pressure pipes and fittings

Pipes for water supply shall be of the class stated. Pipes of 40mm diameter and smaller shall

be plain ended with solvent welded uPVC loose sockets and fittings. Pipes of 50mm diameter

and greater shall have sockets and spigots with push-in type integral rubber ring joints. Bends

shall be uPVC and all other fittings shall be cast iron, all with similar push-in type joints.

Copper pipes

Pipes shall be hard drawn and half-hard pipes of the class stated. Class 0 (thin walled hard

drawn) pipes shall not be bent. Class 1 (thin walled half-hard), class 2 (half-hard) and class 3

(heavy walled half-hard) pipes shall only be bent with benders with inner and outer formers.

Fittings to copper waste, vent and anti-syphon pipes, capillary solder fittings and compression

fittings shall be "Cobra Watertech" type. Capillary solder fittings shall comply with ISO 2016.

Only compression fittings shall be used in walls or in ground.

Reducing fittings

Where fittings have reducing ends or branches they are described as "reducing". In the case of

pipes with diameters not exceeding 60mm only the largest end or branch size is given. Should

the contractor wish to use other fittings and bushes or reducers he may do so on the

understanding that no claim in this regard will be entertained. In the case of pipes with

diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will

be entertained.

Fixing of pipes

Unless specifically otherwise stated, descriptions of pipes shall be deemed to include fixing

and chasing into walls etc, casting in, building in or suspending not exceeding 1m below

suspension level.

Wire gratings

Descriptions of gutter outlets etc shall be deemed to include wire balloon gratings.

C2.2 Bills of Quantities

Elandsfontein/Isando 60 of 96

Page 61: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Laying, backfilling, bedding, etc of pipes

Pipes shall be laid and bedded and trenches shall be carefully backfilled in accordance with

manufacturers' instructions.

Where no manufacturers' instructions exist pipes shall be laid in accordance with clauses 5.1

and 5.2 of each of the following: SABS 1200 L : Medium-pressure pipelines SABS 1200 LD :

Sewers SABS 1200 LE : Stormwater drainageSABS 1200 LC : Cable ductsPipe trenches etc

shall be backfilled in accordance with clauses 3, 5.5, 5.6, 5.7 and 7 of SABS 1200 DB :

Earthworks (Pipe trenches).Pipes shall be bedded in accordance with clauses 3.1 to 3.4.1, 5.1

to 5.3 and 7 of SABS 1200 LB : Bedding (Pipes). Unless otherwise described bedding of rigid

pipes shall be class B bedding.

Excavations

No claim for rock excavation will be entertained unless the contractor has timeously notified the

quantity surveyor thereof prior to backfilling. "Soft rock" and "hard rock" shall be as defined in

"Earthworks".

Flush pans

Flush pans shall have straight or side outlets and "P" or "S" traps as necessary.

Stainless steel basins, sinks, wash troughs, urinals, etc

Units shall have standard aprons on all exposed edges and tiling keys against walls where

applicable.

Waste unions

Descriptions of waste unions shall be deemed to include rubber or vulcanite plugs and chains

fixed to fittings.

C2.2 Bills of Quantities

Elandsfontein/Isando 61 of 96

Page 62: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

RAINWATER DISPOSAL

0,8mm Chromadek fascia gutters and accessories

1 100 x 125mm Ogee eaves gutters m 270

2 Extra over 100 x 125mm Ogee eaves gutter for stopped end No 10

3

Extra over 100 x 125mm Ogee eaves gutter for outlet with nozzle for 200 mm long in bottom of

gutter for 110 mm diameter rainwater pipe including flexible coupling and domical grating No 63

0,8mm Chromadek downpipes and accessories, cast into concrete

4 110mm diameter rain water downpipe fixed to pipe clips at 1000mm centres m 312

5 Extra over 110mm rainwater pipe for bend No 63

6 Extra over 110mm diameter rain water pipe for shoe No 63

"Fulbore" cast iron outlets

7 110mm vertical outlet with flat grating No 14

SANITARY PLUMBING INSTALLATION

Sinks

8

"Franke SA94 grade 304 18/10" or equivalent and approved stainless steel single bowl drop-in

sink with right-hand drainer (code 310507) overall size 900 x 535mm with one 460 x 410 x

120mm deep, fitted into kitchen cupboard worktop (elsewhere), complete with all required

accessories and fixing bolts as per manufacturers specifications No 1

9

"Franke Quinline" or equivalent and approved stainless steel double bowl drop-in sink with

satin finish (code QLX 621-120)) overall size 1200 x 500mm wide, fitted into kitchen cupboard

worktop (elsewhere), complete with all required accessories and fixing bolts as per

manufacturers specifications No 2

Basins

10

"Vaal emerald" or equivalent and approved wall mounted white vitreous china wash hand

basin (code 032) size 415 x 500mm with three semi-punched tapholes, integrated overflow,

and chainstay hole through the centre, bolted to wall with 10mm bolts (code 8448Z0) and

concealed wall brackets complete No 7

11

"Duravit" or equivalent and approved wall mounted white vero handrinse wash hand basin

(code 070225) size 450 x 250mm with one taphole, integrated overflow, and chainstay hole

through the centre, bolted to wall with 10mm bolts (code 8448Z0) and sealed with ABE Dow

corning 785 acetoxy silicone sealnt complete No 1

12

"Vaal weaver" or equivalent and approved rectangular surface mounted vanity (code

704201012) with one tap hole on vanity surface including silicone sealant around edges No 6

13

"Franke" or equivalent and approved wall mounted washtrough (code SIRX 342) in grade 304

stainless steel fitted to pair of stainless steel brackets pop riveted to flange No 2

WC's

14

"Vaal Orchid" or equivalent and approved vitreous china close-coupled WC (White) suite-pan

(code 439100) comprising 90B0 outlet with top inlet pan, fixed on and including floor bracket

(code: 8082Z0) and Jazz thermoset seat (code: 8531Z0) complete with fitments, flush pipe,

dual-flush handle, 110mm "GI Two-way" vent valve, 110mm pan connector etc. and all other

necessary fittings to complete the full installation. No 12

C2.2 Bills of Quantities

Elandsfontein/Isando 62 of 96

Page 63: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

15

"Vaal Orchid" or equivalent and approved vitreous china close-coupled WC (White) suite-pan

(code 439100) comprising 90B0 outlet with top inlet pan, fixed on and including floor bracket

(code: 8082Z0) with Geberit concealed cistern for wall-hung water closet and Jazz thermoset

seat (code: 8531Z0) complete with fitments, flush pipe, dual-flush handle, 110mm "GI Two-

way" vent valve, 110mm pan connector etc. and stop valve protection cover for service

opening and protection cover for flush pipe, and all other necessary fittings to complete the full

installation. No 6

Urinal

16

"Vaal Lavatera" or equivalent and approved white vitreous china wall mounted top inlet urinal

(code 705426) including 38mm chromium plated domical grating (code 8787Z0) and

chromium plated top inlet spreader (code 7054Z1), fixed on and including two hanger brackets

(code 8127Z0) and urinal division (code 7052) fixed with and including fixing screws and

hanger brackets No 3

Floor drains

17

Stainless steel floor drain including 70mm water seal to ensure odour free operation complete

as per manufacturers specifications No 12

Sumps, catchpits etc

18 500 x 500 Junction box 500mm deep internally No 8

19 500 x 500 Dished grating and frame No 8

WASTE UNIONS, ETC

Waste unions for basins, sinks, etc shall comprise chromium plated waste union with grating,

rubber washers and locknut

From approved supplier

20

32mm Chrome plated basin waste (code: 301) with 62mm diameter flange, 80mm shank,

slotted, with backnut, plug, chain and stay No 21

21

40mm Chromium plated heavy sink waste (code 310) with 86 diameter flange, 93mm shank,

slotted, with plug and backnut No 4

22 40mm Chrome plated anti-theft plug with spindle (code 309-40) No 19

TRAPS ETC

From approved supplier

23 40mm 373 RB shower P-trap with telescopic drain cover No 10

24 40mm CP deep seal bottle trap with outlet for 50mm PVC (code 365/50) No 22

25 50mm uPVC one-way vent valve No 0

26 110mm uPVC one-way vent valve No 0

TAPS, VALVES, ETC TO SANITARY WARE

From approved supplier

27 Brass 20mm strainer No 2

28 Brass 50mm strainer No 2

29 Brass 50mm Non-return valve No 2

30 Brass 80mm Non-return valve No 2

31 "Cobra Watertech" or equivalent and approved lever ballcock mini MXF (code 1030-15) No 21

32 Angle regulating valve with 350mm long service connector (code 232/350) No 5

C2.2 Bills of Quantities

Elandsfontein/Isando 63 of 96

Page 64: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

33

"Cobra Watertech Gala" or equivalent and approved sink mixer (code GA-670) chrome plated,

one hole single lever with swivel outlet and mounting kit, complete as per manufacturer's

specifications No 2

34

"Cobra Watertech Strata" or equivalent and approved chrome plated single lever basin mixer

with 110mm body extension and one taphole (code SA-851R), complete as per manufacturer's

specifications No 7

35

"Cobra Watertech" or equivalent and approved self-closing pillar tap with chrome plated finish

(code COB-KM2-102) non-hold open, including flow controller, backnut and washer complete

as per manufacturers specifications (flow cycle 1-20 seconds) No 6

36

"Cobra Watertech Medishift" or equivalent and approved single lever action basin mixer (code

NM-859) with chrome plated finish No 1

37

"Cobra Watertech" or equivalent and approved chromium plated elbow action wall mixer with

swivel outlet and mounting kit (code 515/055-211) No 2

38

"Cobra Watertech Gala" or equivalent and approved chromium plated single lever shower

mixer (code GA-656) with mounting kit and temperature and flow control cartridge classic

handle No 10

39

"Cobra Watertech" or equivalent and approved chromium plated 200mm diameter water

saving shower head with restricted flow (code 075-150) with ball-joint connector and

removable solid spray nipples for cleaning No 10

40

"Cobra Watertech" or equivalent and approved 15mm standard brass plain bibtap (code 100-

15) with flow straightner, complete as per manufacturer's specifications No 6

41

Stop taps (Code: LO-228-15) one hot and one cold per basin complete as per manufacturers

specifications No 19

42 Stop taps (Code: LO-228-15) per WC complete as per manufacturers specifications No 21

43

12mm Lockable "Cobra" or similar approved rough brass hose bibtap (Code 209/1-15x3/4)

with one hose union with wingnut and lining for 1" hose No 2

44 25mm Pressure reducing valve No 1

45 32mm Pressure control valve No 1

46 "Cobra FJ6000" or equivalent and approved flush valve No 5

47 Samba dual-flush actuator (code 115.770.46.1) in chrome plated matt finish No 5

48 Top inlet flushvalve (code FM1:214) with C-FM8.8 extension lever No 18

49 DP1 flushfit marley SG47 pan collar No 18

SANITARY PLUMBING

Class 12 uPVC pipes, etc including supports

50 32mm Pipes chased into brickwork m 12

51 40mm Pipes m 17

52 50mm Pipes m 16

53 50mm Pipes chased into brickwork m 54

54 110mm Pipes m 15

55 110mm Pipes chased into brickwork m 12

56 50mm Diameter vent piping m 42

57 110mm Diameter vent piping m 36

C2.2 Bills of Quantities

Elandsfontein/Isando 64 of 96

Page 65: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Extra over uPVC pipes for fittings

58 32mm Bend No 14

59 32 x 50mm Reducing junction No 12

60 50mm Bend No 20

61 50mm Access bend No 9

62 50mm Junction No 16

63 50mm Access Junction No 2

64 50mm Access double junction No 6

65 50 x 110mm Reducing junction No 12

66 110mm Bend No 10

67 110mm Junction No 8

68 110mm Access junction No 12

69 110mm Access double junction No 2

70 110 x 50mm Eccentric reducer No 2

71 110mm Pan connector No 18

72 110mm Rodding eye No 10

110mm Admittance air valve/vent valve No 13

Testing

73 Testing waste pipe system Item 1

HOT AND COLD WATER SUPPLY

PEX-B Pipes, etc including supports

74 15mm Pipes chased into brickwork including brown paper lagging m 88

75 25mm Pipes chased into brickwork including brown paper lagging m 91

Extra over PEX-B pipes for fittings

76 15mm Pipes m 68

77 25mm Pipes m 95

Isolating Valves

Ball type Isolating Valve complete with couplings to piping, etc., all strictly in accordance with

Manufacturer's instructions and complying to SANS 1056 - 3

78 15mm Diameter No 4

79 25mm Diameter No 4

WATER METER

Brass bodied type water meter complete with thread connections,valves and all other

necessary fittings to complete the installation. Water meter to be housed in a valve box as per

manufacturer's specification.

80 35 Diameter water meter No 1

C2.2 Bills of Quantities

Elandsfontein/Isando 65 of 96

Page 66: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SUNDRIES

81 Cutting into 110mm uPVC pipe for fixing to 15mm PEX-B pipe No 4

82 Cutting into 110mm uPVC pipe for fixing to 25mm PEX-B pipe No 4

83 All inspections, testing and commissioning of the complete hot and cold water installation Item 1

84

Allow for manual switch over from heat pump mode to geyser mode, in case of failure of heat

pump Item 1

ELECTRIC HOT WATER CYLINDERS

Monoblock Geyser Heat Pump, complete with all necessary fitting,gauges and connections as

per SANS 10254 and 10142-1 requirements.

85

200Litres Monoblock solar geyser heat pump, electric element, insulation material if necessary

and all other necessary accessories No 1

86

300Litres Monoblock solar geyser heat pump, electric element, insulation material if necessary

and all other necessary accessories No 2

87

2.5 square metre solar aperture area Direct Thermosyphon split system complete with

circulation pumps. Pumps and all necessary electrical supply to be provided from the DB.

Complete with Solar connections and all necessary plumbing connections to be provided. No 6

88

15Litre under/over basin water heater c/w all necessary fittings and supporting equipment as

per manufacturer's specifications. No 1

Support frames

89

Supply ,deliver, off-load, store on site support frames including all fixing bolts and accessories

and flashing, complete with shelter from environmental exposures. All solar collector tubes

support frames to be galavanised c/w all necessary fixing bolts. No 3

C2.2 Bills of Quantities

Elandsfontein/Isando 66 of 96

Page 67: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Plumbing fixtures

90

15mm Brass type bib tap, complete with all necessary fittings and connections to external

reticulation. No 1

FIRE PROTECTION, APPLIANCES, ETC

Fire appliances

NOTE:All fire protection equipment to have adequate fire protection signage as per the

National Building Regulations - SANS 0400Contractor to note pricing must include for all SABS

approved piping, nozzles, T's, elbows, connections, penetrations, reducers, etc to make a

complete and workable installationThe complete fire installation to be galvanized piping as per

relevant SANS and local council requirements. All hose reels will be fitted 1 800mm above

floor level and will be fitted with a pressure gauge to easily verify system pressure.

Supply and install SANS62 Medium wall galvanised steel Fire Hydrant Distribution pipes

including cutting or drilling for branch outlets, including preparation, cutting, rolling of grooved

ends, grooved end pipe couplings, jointing, cleaning, testing, bracketing and hangers. Steel

piping installed underground shall be protected using b

Painting and identification of all fire pipe work as per SANS. Painting and marking of all

exposed pipe work, equipment where required. (Colour: Red/Yellow)

91 110mm Pipes laid in and including trenches m 139

92 75mm Pipes laid in and including trenches m 0

93 25mm Pipes laid in and including trenches m 32

Pumps

94 Twin Booster Connection No 1

95 100mm Diameter Non-return valve No 2

Fire equipment

96

4,5kg DCP Fire Extinguisher including hardwood backboard plugged, screwed and pelleted to

wall No 12

97

Supply & Install Fire Hose Reels (30m long) c/w chromium plated 25mm valve, pressure

guage & cock, fittings, fixings, etc. No 6

Fire signage

98

Allow for the production and fixing of all statutory fire signage on chromadek or similar

approved material No 30

Sundries

99

Unreinforced concrete in thrust blocks at bends, tees, etc including necessary extra

excavation, formwork, etc m3 5

100 All inspections, testing and commissioning of the complete fire water installation Item 1

C2.2 Bills of Quantities

Elandsfontein/Isando 67 of 96

Page 68: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SLEEVES

Plastic sleeves for pipes not exceeding 100mm diameter

101 Sleeve not exceeding 250mm long No 40

Plastic sleeves for pipes exceeding 100mm and not exceeding 200mm diameter

102 Sleeve exceeding 250mm and not exceeding 500mm long No 10

HOLES ETC

Core drilling of hole for pipe not exceeding 50mm diameter

103 200mm Reinforced concrete slab, beam, wall, etc No 25

Core drilling of hole for pipe exceeding 50mm and not exceeding 100mm diameter

104 200mm Reinforced concrete slab, beam, wall, etc No 15

TESTING AND QUALITY ASSURANCE

105

On completion, allow for high pressure jet cleaning to the entire internal and external drainage

system on the instruction and to the satisfaction of the engineer Item 1

106

Allow for competent personnel to carry out "Quality Assurance" and necessary documentation

thereof as the contract proceeds. These documents to form part of the monthly certification

documentation Item 1

Total Carried Forward To Section Summary

SECTION 2

BILL No. 16

GLAZING

TOPS, SHELVES, DOORS, MIRRORS, ETC

6mm Silvered float glass copper backed mirrors with polished edges holed for and fixed with

chromium plated dome capped mirror screws with rubber buffers to plugs in brickwork or

concrete

1 Mirror 415 x 900mm high No 14

2 Mirror 1 200 x 800mm high No 2

3 Mirror 3000 x 1500mm high No 2

Total Carried Forward To Section Summary

SECTION 2

BILL No. 17

PAINTWORK

SUPPLEMENTARY NOTES:

Adjoining paint surfaces: The contractor is to take into consideration that the paintwork to the

external facade will be applied to different textures as well as differ in paint specification and

colour adjoining each other. No claims whatsoever for cost or time extention will be

entertained for the above-mentioned

Quality monitoring of paint surfaces: The contractor needs to allow for quality checks of all

primer coats by an approved authority (for example Qualitec) prior commencement of final

coats. No claims whatsoever for cost or time extention will be entertained for the above-

mentioned

C2.2 Bills of Quantities

Elandsfontein/Isando 68 of 96

Page 69: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

PAINTWORK ETC TO NEW WORK

SPECIALIST PAINT TO FLOOR COVERINGS

6mm Thick "BASF Ucrete" or equivalent and approved polyurethane floor finish applied by

approved applicator in accordance with manufacturers specifications, complete with trafficable

joints, etc

1 On power floated floors m2 729

ON FLOATED PLASTER

Prepare and apply one coat primer and two coats "Plascon Professional Superior" or

equivalent and approved matt acrylic emulsion paint

2 On internal walls m2 2737

3 On concrete soffits and beams m2 161

4 On concrete walls m2 65

5 On concrete columns m2 5

Prepare and apply one coat primer and two coats "Plascon Surecoat" or equivalent and

approved matt acrylic paint (Colour: white)

6 On soffits m2 161

7 Internal raking soffits m2 5

Prepare and apply one coat of masonry primer, one coat medium texture undercoat and two

coats washable stain resistant pure acrylic paint

8 On external walls m2 2070

9 On sills, thresholds, etc m2 45

ON PLASTER BOARD

Prepare and apply one coat primer and two coats "Plascon Professional Superior" or

equivalent and approved matt acrylic emulsion paint (Colour: white)

10 On ceilings and cornices m2 91

ON WOOD

Prepare and apply one coat wood primer to SABS 1313 "white", one coat universal undercoat

to SABS 681 grade 1 and two coats high gloss polyurethane non drip enamel paint to SABS

630

11 On doors and frames m2 139

Three coats "Nova 17" or equivalent and approved polyurethane matt varnish

12 On doors and frames m2 36

Prepare and apply one coat wood primer, one coat universal undercoat and two coats

polyurethane alkyd enamel paint

13 On skirtings, rails, etc not exceeding 300mm girth m 95

C2.2 Bills of Quantities

Elandsfontein/Isando 69 of 96

Page 70: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

ON METAL

Spot priming defects in pre primed surfaces with zinc chromate primer and applying one coat

universal undercoat and two coats gloss enamel paint on steel

14 On doors and door frames m2 26

15 On gates, grilles, burglar screens, balustrades, etc (both sides measured over the full flat area) m2 53

Total Carried Forward To Section Summary

SECTION 2 SUMMARY

Earthworks

Foundations

Concrete, Formwork and Reinforcing

Masonry

Waterproofing

Roof Coverings etc

Carpentry and Joinery

Ceilings, Partitions and Access Flooring

Floor Coverings, Wall Linings etc

Ironmongery

Structural Steelwork

Metalwork

Plastering

Tiling

Plumbing and Drainage

Glazing

Paintwork

Total Carried Forward To Final Summary

SECTION 3

BILL No.1

SITE SERVICES (PROVISIONAL)

SUPPLEMENTARY PREAMBLES

"Polycop" polypropylene pipes:

Polypropylene pipes 54mm diameter and under shall be seamless copper coloured class 16

pipes jointed with "Fast-fuse" heat welded thermoplastic or brass compression fittings as

designed for use with copper pipes as stated

Pipes shall be firmly fixed to walls etc with coloured nylon snap-in pipe clips with provision for

accommodating thermal movement and jointed and fixed strictly in accordance with the

manufacturer's instructions

All pipe diameters are nominal external

C2.2 Bills of Quantities

Elandsfontein/Isando 70 of 96

Page 71: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

"Polylink" polypropylene pipes:

Polypropylene pipes 63mm diameter and over shall be class 12 pipes jointed with cast iron

"Supraclamp" running joints

Fusion welded bends, once or twice mitred as necessary, and tees shall be factory

manufactured

Fusion welded bends and tees shall include jointing to pipes with PVC rubber ring double Z

joint couplers

Branch tees shall include flanged and bolted joints to "Polycop" branch pipes in addition and

for brass compression male iron to copper straight couplers

Reducers shall include jointing to pipes with PVC rubber ring double Z joint couplers and

reducers shall be of sufficient overall length to accommodate same

All pipes shall be jointed and fixed strictly in accordance with the manufacturer's instructions

All pipe diameters are nominal external

Concrete pipes:

Pipes shall be jointed with ogee joints with rubber collars or socket and spigot joints with

rubber rings

Vitrified clay pipes:

Pipes shall rest on solid ground and, where necessary, pockets of sufficient size shall be cut

around joints to enable the jointing to be properly performed or, alternatively, pipes shall be

bedded full length on and including unreinforced concrete laid in a semi-dry state immediately

before pipes are laid

Sewer and drainage pipes and fittings shall be jointed and sealed with butyl rubber rings

uPVC pipes and fittings:

Soil, waste and vent pipes and fittings shall be solvent weld jointed

uPVC pressure pipes and fittings:

Pipes for water supply shall be of the class stated

Pipes of 40mm diameter and smaller shall be plain ended with solvent welded uPVC loose

sockets and fittings

Pipes of 50mm diameter and greater shall have sockets and spigots with push in type integral

rubber ring joints. Bends shall be uPVC and all other fittings shall be cast iron, all with similar

push-in type joints

Copper pipes:

Pipes shall be hard drawn and half-hard pipes of the class stated. Class 0 (thin walled hard

drawn) pipes shall not be bent. Class 1 (thin walled half-hard), class 2 (half-hard) and class 3

(heavy walled half-hard) pipes shall only be bent with benders with inner and outer formers.

Fittings to copper waste, vent and anti-syphon pipes, capillary solder fittings and compression

fittings shall be "Cobra Watertech" type. Capillary solder fittings shall comply with ISO 2016.

Only compression fittings shall be used in walls or in ground

Fixing of pipes

Unless specifically otherwise stated, descriptions of pipes shall be deemed to include fixing to

walls etc, casting in, building in or suspending not exceeding 1m below suspension level

C2.2 Bills of Quantities

Elandsfontein/Isando 71 of 96

Page 72: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Lead pipes and fittings

All soldered joints shall be wiped and brass unions shall be used for jointing lead to steel

Reducing fittings

Where fittings have reducing ends or branches they are described as "reducing". In the case

of pipes with diameters not exceeding 60mm only the largest end or branch size is given.

Should the contractor wish to use other fittings and bushes or reducers he may do so on the

understanding that no claim in this regard will be entertained. In the case of pipes with

diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will

be entertained

Wire gratings

Descriptions of gutter outlets etc shall be deemed to include wire balloon gratings

Septic tanks

Descriptions of septic tanks shall be deemed to include excavation, bedding and jointing,

concrete base slabs, jointing to drains and backfilling, compaction, etc all in accordance with

the manufacturer's instructions

Exposed concrete surfaces

Exposed surfaces of concrete stormwater channels, cover slabs, inspection eye marker slabs,

gulley tops, cleaning eye tops, catchpits, inspection chambers, etc shall be finished smooth

with plaster

Excavations

No claim for rock excavation will be entertained unless the contractor has timeously notified the

quantity surveyor thereof prior to backfilling

"Soft rock" and "hard rock" shall be as defined in "Earthworks"

Laying, backfilling, bedding, etc. of pipes

Pipes shall be laid and bedded and trenches shall be carefully backfilled in accordance with

manufacturers' instructions

Where no manufacturers' instructions exist pipes shall be laid in accordance with clauses 5.1

and 5.2 of each of the following: SABS 1200 L : Medium-pressure pipelines SABS 1200 LD :

Sewers SABS 1200 LE : Stormwater drainage Pipe trenches etc shall be backfilled in

accordance with clauses 3, 5.5, 5.6, 5.7 and 7 of SABS 1200 DB : Earthworks (Pipe trenches)

Pipes shall be bedded in accordance with clauses 3.1 to 3.4.1, 5.1 to 5.3 and 7 of SABS 1200

LB : Bedding (Pipes). Unless otherwise described bedding of rigid pipes shall be class B

bedding

Steel sectional water tanks

Tanks shall comply with SABS CKS 114

"Densyl" petrolatum anti-corrosion tape as manufactured by Denso SA (Pty) Ltd.

Pipes to be taped shall be coated with the appropriate primer and the tape shall be applied

with minimum 15mm lap per spiral unless otherwise described

Couplings and fittings to pipes shall be taped in strict accordance with the manufacturer's

instructions including all mastic, tape, "Layflat" sheeting, securing of same, etc

C2.2 Bills of Quantities

Elandsfontein/Isando 72 of 96

Page 73: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

STORMWATER DRAINAGE

Excavate in all materials for storm water drainage, compact and dispose of surplus material

[C# 8.3.2]

Class 100D concrete stormwater pipes up to 450mm diameter for depths: Over and Up to:

1 1,0m to 2,0m m 168

Extra over for (Provisional):

2 Soft rock/Intermediate excavation [C# 8.3.2 (b1)] m3 25

3

Hard rock excavation: rate to include excavation and transportation of excavated hard rock to

a location to be identified by the contractor [C# 8.3.2 (b2)] m3 16

4

Excavate of unsuitable material from trench bottom and dispose to suitable location to be

identified by the contractor (Provisional) [C# 8.3.2 (c)] m3 115

Bedding (Class C)

From commercial sources:

5 Selected granular material - bedding m3 82

6 Selected fill material - blanket m3 33

Excavation Ancillaries

Make up deficiency in backfill material (provisional) [C# 8.3.3.1]

7 From other necessary excavations on site m3 49

8 By importation from commercial or of-site sources selected by the Contractor m3 20

C2.2 Bills of Quantities

Elandsfontein/Isando 73 of 96

Page 74: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Pipework

Class 100D concrete pipes

Supply, lay and bed according to manufacturers specifications

9 375mm diameter m 168

Construct catch pit (including covers) according to Engineer specifications for depths: Over

and Up to:

10 0,5m to 1,0m m 3

Sundries

11 Connect to existing system [SANS 1200LD; C# 8.2.11] No 2

SOIL DRAINAGE

Excavation [SANS 1200DB]

Excavate by machine in all materials for trenches, backfill, compact to 93% of MoD. AASHTO

(100% for sand) and dispose of surplus material [C# 8.3.2]

Class 34 uPVC pipes up to 250mm diameter for depths: Over and Up to:

12 0,0m to 1,0m m 441

Extra over for (Provisional):

13 Soft rock/Intermediate excavation [C# 8.3.2 (b1)] m3 50

14

Hard rock excavation: rate to include excavation and transportation of excavated hard rock to

a location to be identified by the contractor [C# 8.3.2 (b2)] m3 33

15

Excavate of unsuitable material from trench bottom and dispose to suitable location to be

identified by the contractor (Provisional) [C# 8.3.2 (c)] m3 231

Bedding (Class C)

From commercial sources:

16 Selected granular material - bedding m3 165

17 Selected fill material - blanket m3 66

Excavation Ancillaries [SANS 1200 DB]

Make up deficiency in backfill material (provisional) [C# 8.3.3.1]

18 From other necessary excavations on site m3 99

19 By importation from commercial or of-site sources selected by the Contractor m3 40

Existing services [C# 8.3.5]

Services that intersect a trench

20 Pipes up to 600mm diameter No 10

21 Cables No 15

22 Telkom optic fibre cables No 5

Services that adjoin a trench

23 Pipes up to 600mm diameter m 15

24 Cables m 10

25 Kerbs m 35

C2.2 Bills of Quantities

Elandsfontein/Isando 74 of 96

Page 75: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

26 Road m 15

27 Telkom optic fibre cables m 5

Pipework

Supply, handle, lay, bed (bedding as for flexible pipes), Class 34, uPVC sewer pipes [C# 8.2.1]

28 110mm diameter m 79

29 160mm diameter m 362

160mm diameter vertically or ramped to rodding eyes, etc m 8

Extra over class 34 uPVC pipes for uPVC fittings

30 110mm Bend No 6

31 110mm Junction No 3

32 160 x 110mm Taper pipe No 3

33 160mm Bend No 26

34 160mm Junction No 10

35 160mm Access junction No 6

Construct manholes (including covers) according to Engineer specifications for depths: Over

and Up to:

36 0,5m to 1,0m No 13

Oil & grease traps

37

3 x Compartment concrete oil & grease trap including 3no covers and frames, etc complete as

per engineer's specification on drawing no. 16-0373107C/T/06 No 1

38 Sumps, catchpits, inspection chambers, etc (including gratings and covers) No 2

Sundries

39 Concrete encasing to 160mm horizontal pipes m 209

40 Concrete encasing to 160mm vertical pipes m 8

41 100mm Cast iron "ABC" cleaning eye - RE No 6

42 Connect to existing system [SANS 1200LD; C# 8.2.11] No 1

43 Testing soil drainage system Item 1

WATERMAINS

Services that intersect trenchs [C# 8.3.5 (a)]:

44 Pipes up to 600mm diameter No 12

45 Cables No 15

46 Telkom optic fibre cables No 5

Services that adjoin a trench

47 Pipes up to 600mm diameter m 10

48 Cables m 5

49 Telkom optic fibre cables m 5

C2.2 Bills of Quantities

Elandsfontein/Isando 75 of 96

Page 76: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

50 Kerbs m 25

51 Road m 35

Excavation [SANS 1200DB]

Excavate by machine in all materials for trenches (970mm wide, domestic and fire lines in

same trench), backfill, compact and dispose of surplus material [C# 8.3.2 (a)]

52

Water mains for, not exceeding 250mm diameter pipes exceeding 1m and not exceeding 1.5m

deep m 469

Extra over for [C# 8.3.2 (b)]:

53 Soft rock/Intermediate excavation [C# 8.3.2 (b1)] m3 49

54

Hard rock excavation [C# 8.3.2 (b2)]. Rate to include excavation and transportation of

excavated material to a location to be identified by the contractor m3 32

Excavation Ancillaries

Make up deficiency in backfill material (provisional) [C# 8.3.3.1]

55 From other necessary excavations on site m3 65

Imported backfill materials from:

56 Commercial or off-site sources selected by Contractor. m3 78

57 Compaction in road reserves [C# 8.3.3.3] m3 32

Bedding from commercial sources [SANS 1200 LB]

58 Selected granular material [C# 8.2.2.3] m3 162

59 Selected fill material [C# 8.2.2.3] m3 65

Pipework [SANS 1200 L]

Supply, handle, lay, bed (bedding as for flexible pipes), and disinfect, Class 12, uPVC pipes

[C# 8.2.1]

60 75mm Diameter pipes m 292

61 110mm Diameter pipes m 178

Extra over pipes for supply, handle, lay, bed, specials and fittings, including cutting pipes to

length where required for uPVC bends class 16 uPVC with socket couplings [C# 8.2.2/3]

62 75mm 90 degree bend No 15

63 75mm 45 degree bend No 5

64 75 x 75mm T-piece No 4

65 75 x25mm Reducer T-piece No 4

66 75mm End cap No 2

67 110mm 90 degree bend No 16

68 110mm 45 degree bend No 4

69 110 x 110mm T-piece No 2

70 110mm End cap No 2

C2.2 Bills of Quantities

Elandsfontein/Isando 76 of 96

Page 77: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Fire hydrants in accordance with Engineer specification on diameter, installed complete with all

fittings

71

Supply and installation Fire Hydrant complete with 65 mm dia brass right angle fire hydrants

complete with and all accessories mounted inside cabinets (if required) and/or surface

mounted and connected to piping. No 2

72 Concrete anchor/thrust blocks, prescribed concrete Grade 15 m3 2

Flanged resilient seal gate valve fitted to flange adaptor

73 65mm Diameter No 2

Valve and hydrant brick chambers (including covers)

74 Valve chamber as per Detail Drawing No 4

75 Fire Hydrant chamber as per detail drawing No 2

Building connections:

Supply, lay, bed, backfill and test building connections

76 25mm diameter Class 16 uPVC pipes m 2

Extra over for fittings and specials:

C2.2 Bills of Quantities

Elandsfontein/Isando 77 of 96

Page 78: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Saddles to Engineer specification (see typical detail on drawing), complete with packings,

bolts, nuts, and couplings for use on:

77 25mm Class 16 uPVC pipes No 4

Male threaded elbow:

78 25mm diameter No 4

79 75mm diameter No 4

80 110mm diameter No 2

81 Markings on kerb for Valves and Fire Hydrants No 6

Connecting to existing pipeline

82 160mm Class 12 uPVC pipe No 1

Non-return valves

83 75mm Diameter No 3

84 110mm Diameter No 2

Ancillaries

85 Irrigation tap No 2

Sundries

86

Unreinforced concrete thrust blocks at bends, tees, etc including necessary extra excavation,

formwork, etc m3 2

87 Testing water pipe system Item 1

Total Carried Forward To Section Summary

SECTION 3

BILL No. 2

ROADWORKS, PARKING AREAS, ETC (PROVSIONAL)

SUPPLEMENTARY PREAMBLES

General

Wherever possible abridged descriptions have been used for those items in this Bill which

appear under the main trade headings in subsequent Bills. The full descriptions of these items

in the Preambles, as referred to above, to the various trade bills are to, and do apply equally to

this section The descriptions are generally in accordance with the most recent edition of The

Standard System for Measuring Building Work.Special reference is made to SABS 1200

specifications for civil worksSpecial reference is made to Specifications and details of

Department of Public Works Drainage Detail (December 1998)Special reference is made to

Specifications of Materials and Methods to be used of Department of Public Works (DP 371)

Protection of existing services

The contractor must make allowance against the relevant items for the following: (a)

Necessary care to be taken when excavating near existing services in or across the path of

excavations (b) Protection and maintaining such service in operation by means of temporary

supports or shoring as necessary (c) Delays and disruption of the progress of the work due to

the existence of the service (d) Repairs necessitated by damage caused by the contractor

C2.2 Bills of Quantities

Elandsfontein/Isando 78 of 96

Page 79: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Controlling and re-routing of traffic

The contractor must make allowance next to the relevant item for the following: (a) Temporary

road traffic signs required for controling traffic (b) Construction and maintenance of bypass/es

and associated facilities where and when required (c) Warning lights, flagmen, barricades

where and when required (d) Ensure that the road is open at the end of each day's work and

is left in good and safe trafficable condition complete with signs and the necessary protection

facilities

SABS specifications references

Where reference is made to SABS 1200 specifications (all sections) it will be deemed to

exclude clause 8 "Measurements and Payments"

Nature of ground

Descriptions of excavations shall be deemed to include all ground conditions classifiable as

"earth" Conditions of a more difficult character are indicated and these are separately

measured.

Carting away of excavated material

Descriptions of carting away of excavated material shall be deemed to include loading

excavated material onto trucks directly form the excavations or, alternatively, from stock piles

situated on the building site

Type and quality of material supplied by the Contractor

The type and quality of imported materials G3, G4, G5 & G7 supplied by the contractor must

comply with TRH 14 "Guidelines for road and construction materials" issued by CSIR Where

sand is substituted for imported material type G7, or where sand is in situ, the compaction is to

be 100% Mod AASHTO density to a depth of 400mm for in-situ sand

INTERLOCKING PLANTER BLOCKS

"Loffelstein" precast concrete interlocking planter blocks finished smooth on exposed surfaces

1

Retaining structure with stepped face and curves as required to suit slopes of 65 degrees

"Loffelstein L300" interlocking planter blocks laid with horizontal bed joints to 5 degree slope

including backfilling with earth obtained from the excavations including cement stabilization as

deemed necessary and filling the blocks with garden soil lightly tamped as the work proceeds m2 88

ROADWORKS (MINOR ROADS)

Preparation of site [1200DM]

Rip, shape and compact in-situ road-bed material to minimum 93% Mod AASHTO density

(100% for sand) [C# 8.3.3]

2 150mm for roads and parking m2 2666

3 150m for platforms m2 2712

Earthworks [SANS 1200 DM]

Open face excavation over sloping site

4

Open face excavation to form platform under parking areas etc and depositing excavated

material over site including haulage not exceeding 1km from perimeter of excavations m3 2151

Extra over for (Provisional):

5

Intermediate rock excavation: rate to include excavation and transportation of excavated hard

rock to a location to be identified by the contractor [C# 8.3.2 (b2)] m3 323

6

Hard rock excavation: rate to include excavation and transportation of excavated hard rock to

a location to be identified by the contractor [C# 8.3.2 (b2)] m3 215

C2.2 Bills of Quantities

Elandsfontein/Isando 79 of 96

Page 80: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

7

Excavate and dispose of unsuitable material from trench bottom to suitable location to be

identified by the contractor (Provisional) m3 1345

Sub-grade [SANS 1200 DM]

8

Over site of G9 material in accordance with SABS 1200 DM compacted to 93% AASHTO

density m3 407

Sub-base [SANS 1200 ME]

9

Over site of G5 material in accordance with SABS 1200 DM compacted to 95% Mod AASHTO

density m3 807

Base [SANS 1200 MFL / SDM8-3]

10

Over site of G4 material (stabilized with 2% cement, C4) in accordance with SABS 1200 DM

compacted to 95% Mod AASHTO density m3 807

Keeping excavations free of water

11 Keeping excavations free of all water other than subterranean water Item 1

Prescribed density tests on filling

12 'Modified AASHTO Density" tests No 108

Soil insecticide

13

Under floors etc including forming and poisoning shallow furrows against foundation walls etc,

filling in furrows and ramming m2 5378

Precast concrete block road surfacing

Segmented paving [SANS 1200 MJ]

Construction of paving complete as per specification inclusive of 20mm sandbed [C# 8.2.2]

14

80mm Class 35 MPa concrete type S-A Light grey interlocking pavers to SANS 1058 laid in

herringbone pattern on roads and parking m2 2123

Cutting units to fit edge restraints [C# 8.2.3]

15 Radius not exceeding 20m m 25

16 Radius exceeding 20m and straight sections m 145

Concrete hardstand

35MPa/19mm unreinforced concrete

17 Surface beds cast in panels m3 542

Making and testing concrete strength test cubes

18 150 x 150 x 150mm Test cubes No 98

Finishing top surfaces of concrete with a power float and a coarse hard grass broom

19 Surface beds, slabs, etc to falls and currents m2 2712

Movement joints with 10mm bitumen impregnated softboard through concrete surface beds

20 10mm Joints not exceeding 300mm thick m 285

C2.2 Bills of Quantities

Elandsfontein/Isando 80 of 96

Page 81: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Saw-cut joints

21 3 x 43mm Joints in top of concrete surface beds and reamed 8mm wide x 8mm deep m 1329

Vertical joggle construction joints through concrete, including thick cement slurry to one face

22 Surface beds not exceeding 300mmm thick and reamed 8mm wide x 8mm deep m 271

Two-part grey polysulphide sealing compound, including backing cord, bond breaker, primer,

etc

23 8 x 8mm In joints in top of surfaces m 1329

24 10 x 10mm In joints in top of surfaces, including raking out expansion joint filler as necessary m 271

Kerbing

Kerbing and channelling [SANS 1200 MK / C# 8.2.2 / SDMK8-1]

Precast concrete mountable kerbs on concrete bedding according to detail drawing [SDMK 5-

1]:

25

180 x 280mm High semi-mountable kerbs (SANS 927 Fig 7a) with 150 x 150 x 300mm

unreinforced concrete haunching at the back of each joint, including excavation, backfilling, etc

- BK4 m 882

26

180 x 280mm High semi-mountable kerbs (SANS 927 Fig 7a) with 150 x 150 x 300mm

unreinforced concrete haunching at the back of each joint, circular on plan exceeding 4m

radius, formed with including excavation, backfilling, etc - BK2 m 128

27

300 x 125mm High channels forming V-channels (SANS 927 Fig 14) with 150 x 150 x 300mm

unreinforced concrete haunching at the back of each joint, including excavation, backfilling, etc

- 2 x C1 m 276

28

300 x 125mm High channels forming V-channels (SANS 927 Fig 14) with 150 x 150 x 300mm

unreinforced concrete haunching at the back of each joint, circular on plan exceeding 4m

radius, including excavation, backfilling, etc - 2 x C1 m 25

29

65 x 150mm High edge beam (SANS 927 Fig 13) with 150 x 150 x 300mm unreinforced

concrete haunching at the back of each joint, including excavation, backfilling, etc - E1 m 221

30

65 x 150mm High edge beam (SANS 927 Fig 13) with 150 x 150 x 300mm unreinforced

concrete haunching at the back of each joint, circular on plan exceeding 4m radius, including

excavation, backfilling, etc - E1 m 25

Waterproofing

One layer of 375 micron "Gundle Hyperlastic Orange" waterproof sheeting sealed at laps with

"Superstick" tape

31 Under paving etc m2 5378

Stormwater channels

Concrete stormwater channels

32 Excavation not exceeding 2m deep for channels m3 58

33 Risk of collapse of sides of excavations not exceeding 1,5m deep m2 137

34 35MPa/19mm reinforced concrete in bottoms and sides of channels m3 39

35 Finishing bottoms of channels smooth with a steel trowel to falls m2 89

36 Rough formwork (degree of accuracy II) to sides of channels m2 137

C2.2 Bills of Quantities

Elandsfontein/Isando 81 of 96

Page 82: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

37 Smooth formwork (degree of accuracy I) to sides of channels above sloping bottoms m2 105

38 20 x 20mm Deep recess in sides along top edges for concrete channels m 210

39

10mm Expansion joints with "Flexcell" softboard between concrete bottoms of channels not

exceeding 300mm high m 30

40

10mm Expansion joints with "Flexcell" softboard between concrete sides of channels not

exceeding 300mm wide m 14

41 Type 193 fabric reinforcement in concrete bottoms and sides of channels m2 194

42

30 x 30 x 3mm Angle section corner protectors in varying lengths with 25 x 3mm x 50mm

long flat section bent lugs each 150mm girth welded on at 300mm centres, including

embedding in concrete kg 309

43 Extra over for mitred and welded L-intersection No 16

44

"Mentis" or equivalent and approved grating of 500mm wide banded panels with 30 x 4,5mm

bearer bars in suitable lengths m 105

Ancillary roadworks [SANS 1200 MM]

Road markings [C# 8.4.1]

Prepare and apply one coat white reflective road marking paint on rough concrete surfaces,

paving surfaces and/or asphalt road surfaces

45 100mm Wide line (solid) m 150

46 300mm Wide line (solid) m 24

47 Parking bay numerals 150mm wide extreme No 26

48 Type RTM1 sign road marking "STOP" 3000 x 1500mm wide extreme No 2

49 Type WM5 sign road marking "YIELD" 3000 x 1500mm wide extreme No 2

50 Type RM17.3 "wheelchair" sign road marking 1200 x 1200mm wide extreme No 2

51 Type WM7.3, 4000 x 1000mm wide (extreme) traffic arrow No 12

52 6000 x 2000mm Wide (extreme) traffic island No 2

C2.2 Bills of Quantities

Elandsfontein/Isando 82 of 96

Page 83: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Supply and erect road signs, galvanized, constructed from 1,6 mm thick sheet steel, with

painted background, symbols, characters legends and borders in engineering grade retro-

flective material, complete with pole, mountings and concrete [C# 8.3.6]

53 Standard road sign type R1 [C# 8.3.6] No 2

54 Standard road sign type R2 [C# 8.3.6] No 4

55 Standard road sign type W204 and R201-20 fixed together [C# 8.3.6] No 2

56 Standard road sign type W306 [C# 8.3.6] No 3

BOUNDARY WALLS

Rates for boundary walls are to include for taking all necessary precautions to ascertain

position of and preventing damage to services in ground over which such boundary walls are

to be constructed. Nevertheless, the Contractor shall bear the full responsibility for any such

damage to services which may occur and the cost of consequent repairs shall be for the

Contractor's account, and rates shall include for the occurrence of this risk. The Contractor is

to allow for leveling, filling and excavating to maintain a regular ground level at finished ground

level and the bottom of the boundary wall.

57

Boundary wall consisting of a one and a half brick wall, 2800mm high, with 300 x 300mm wide

brick piers every 10m filled in with concrete, including 700 x 250mm thick 25MPa reinforced

concrete footing (95kg/m3), 200mm high one and a half brick wall in foundations, including bar

reinforcement and necessary waterproofing under and to sides of walls, 2600mm high one and

a half brick wall in superstructure, including bar reinforcement and finished both sides with

"Firelight satin" or equivalent and approved face brickwork in stretcher bond pointed with

recessed joint, 2770mm high, with facebrick brick-on edge header course coping pointed with

recessed joints on all exposed faces, including movement joints formed of 10mm thick

softboard built-in vertically between brickwork every 5m c/c and uPVC weepholes built into

brick walls at relevant intervals, all in accordance with the architect's specifications and

engineer's drawings m 297

Welded mild steel gates, etc

58

Motorized security sliding gate 4 200 x 1 800mm high overall including heavy duty rail, 3mm

diameter galvanized wire with aperture size 76.2mm x 25mm complete with hot dipped

galvanized finish then marine fusion bond coated (acid modified), inclusive of welded gate

frame consisting of 100 x 100mm posts with stays set in and including 20 x 20mm rails, on 500

x 500 x 500mm concrete bases, etc No 1

59

Single pedestrian gate 1200 x 1800mm high overall consisting of 50 x 50 x 3mm hollow

section frame and 50 x 50 x 3mm hollow section horizontal middle rail filled in vertically with

20mm diameter solid bars at 100mm centres and fitted with a pair of suitable pivot hinges and

brackets with fish tail lugs built into brick walls and including ears for padlock, etc complete

(type G03) No 1

LANDSCAPING

60

Allow the budgetary amount of R450,000.00 (Four Hundred and Fifty Thousand Rand) for

landscaping Item 1 R 450 000.00

Total Carried Forward To Section Summary

SECTION 3 SUMMARY

Site Services

Roadworks, Parking Areas, etc

Total Carried Forward To Final Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 83 of 96

Page 84: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION 4

BILL No. 1

ELECTRICAL INSTALLATION

PROJECT AND GENERAL SPECIFICATIONS

The project and general specifications applicable to the electrical work are issued as separate

documents which form part of the tender documentation. No specific reference in the

descriptions in these bills of quantities is made to particular clauses in these specifications.

Tenderers are however to acquaint themselves fully and read the descriptions closely with the

applicable clauses in these specifications for the full intent and meaning of each description.

SUPPLEMENTARY PREAMBLES

The firm which is to carry out the electrical work shall be a firm of experienced specialists to be

employed as a domestic subcontractor to the main contractor.

The measurement of these quantities is based on the contract drawings and will not be subject

to adjustment except in compliance with an order in writing. The quantities for cables, conduit

and conductors are assessed in relation to indicated positions of distribution boards and

outlets etc. and are taken as final unless the contractor is in disagreement, to which end he will

be required to indicate on drawings the sizes and routes of all cables and conduits for each

circuit as built. Similarly the numbers and sizes of conductors in each conduit must be

indicated. This information must be verified by the representative/agent and passed on to the

quantity surveyor for adjustment if necessary. All payments for work done will be based on the

original quantities unless the quantities for the cables, conduits and conductors have been

adjusted in terms of the foregoing.

Prices for conduits shall include for fixing to all types of surfaces, in chases including chasing

and making good, casting in or building into brickwork etc.

GENERAL ITEMS AND PRELIMINARIES

1 Items firm and fixed for duration of contract Item 1

a) Registration as contractor

b) Site establishment

c) Site supervision by accredited person including travel, subsistence, etc.

d) Quality assurance

e) Storage of material, containers and security

f) Contractors insurance

g) Safety Equipment for Workers

h) Health & Safety Plan for Project

i) Provision of a quality control inspector reporting to the Electrical Engineer for the duration of

the contract

j) Amount for carrying out of disturbing work for the duration of the contract

k) Transport of material for storage including installation and disposal of components. The

contractor to provide all required scaffolding, cherry picker, personnel/ operators, ladders,

tools, etc as required.

ELECTRICAL DISTRIBUTION (DETAILS AS PER SCHEMATIC DRAWINGS)

Pricing of items must include for the supply, transport, delivery, testing and off-loading of all

material and equipment including installation, erection, commissioning, labelling, consumables

and handing over in a complete working condition of the works

Supply and install surface mounted distribution boards complete with frames, sub-

frames, doors, chassis, fixtures, fittings, space, busbars, etc as per specification and

drawings

Main Distribution Board

2

Distribution board, 10kA, main, motorized changeover, 1,6mm mild steel, power coated,

busbar included, wired, labelled No 1

C2.2 Bills of Quantities

Elandsfontein/Isando 84 of 96

Page 85: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Distribution Boards to Engine bay and Admin building

3

Distribution board, size medium, 5kA, 1,6mm mild steel, power coated, busbar included, wired,

labelled, normal and backup dedicated sections No 2

Distribution Boards to Guardhouse and Washbay

4

Distribution board, size small, 5kA, 1,6mm mild steel, power coated, busbar included, wired,

labelled No 2

Generator

5 50kVA Backup Diesel Generator No 1

UPS Back-up power

6 30kVA UPS, three phase, online double conversion, 15 minute backup batteries, with cabinet Item 1

Sundries

7 Municipal electricity application and MV services to property minisub location Item 1

CABLE TRAY AND ACCESSORIES

Galvanised medium duty cable tray with adjustable splice sets,including all fixing on

P2000 brackets suspended from steelwork or concrete soffits with 10mm threaded rods

at 1000mm centres, etc complete as per the specification (bends,tees,etc elsewhere

measured)

8 300mm m 120

Fittings and accessories

300mm wide

9 Horizontal elbow No 4

10 Internal elbow No 4

11 Tee No 2

CABLING AND ACCESSORIES

600/1000 V grade PVC/PVC/SWA/PVC stranded copper conductor cable including

terminations

Cable fixed to cable tray or drawn into sleeves and or laid into trenches (cable tray, sleeves

and trenching elsewhere measured)

12

3 x 1,5mm² PVC general purpose copper wire, including accessories and termination -

Building lights m 1500

13

3 x 2,5mm² PVC general purpose copper wire, including accessories and termination -

Building sockets m 1200

14

3 x 1,5mm² PVC Surfix copper wire, including accessories and termination - Engine bay and

outside lights m 500

15

3 x 2,5mm² PVC Surfix copper wire, including accessories and termination - Engine bay

sockets m 500

600/1000 V grade PVC/PVC/SWA/PVC stranded copper conductor cable (terminations

measured elsewhere)

Cable fixed to cable tray or drawn into sleeves and or laid into trenches (cable tray, sleeves

and trenching elsewhere measured)

16 3C x 1,5mm² PVC copper SWA armoured m

17 3C x 2,5mm² PVC copper SWA armoured m 500

C2.2 Bills of Quantities

Elandsfontein/Isando 85 of 96

Page 86: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

18 3C x 4mm² PVC copper SWA armoured m 500

19 4C x 70mm² PVC copper SWA armoured m 200

20 1C x 25mm² BCEW m 100

21 4C x 25mm² PVC copper SWA armoured m 100

22 4C x 50mm² PVC copper SWA armoured m 100

23 4C x 16mm² PVC copper SWA armoured m 50

24 1C x 10mm² BCEW m 300

25 3C x 10mm² PVC copper SWA armoured m 300

Cable terminations complete, including gland shrouds, lugs, number tags, tape, etc and

connecting

26 Termination of 4C x 35-300mm² PVC copper armoured, including accessories No 6

27 Termination of 4C x 10-35mm² PVC copper armoured, including accessories No 18

SMALL POWER AND LIGHTING

Heavy duty Class 34 uPVC pipe ducts to SABS 791 with draw wire for electrical

Sleeves and conduits laid in trenches, including accessories (trenches measured

elsewhere)

28 25mm Diameter m 1000

29 32mm Diameter m 500

Kableflex HDPE pipe ducts to SABS 791 with draw wire for electrical

Sleeves and conduits laid in trenches, including accessories (trenches measured

elsewhere)

30 50mm Diameter m 500

31 110mm Diameter m 150

Galvanised conduit and accessories

Conduit surface mounted to brickwork,concrete,steel or ceiling void or cast into

concrete or built / or chased into brickwork

32 25mm Diameter m 500

Round conduit boxes placed in position for casting into concrete or build or chased

into brickwork

33 25mm Diameter No 65

Round conduit boxes lids

34 Round box lid No 65

Galvanised wall boxes placed in position for casting into concrete or built or chased

into brickwork

35 100 x 50 x 50mm No 28

36 100 x 100 x 50mm No 54

Galvanised wire ducts

37 P1000, 41mm x 41mm m

C2.2 Bills of Quantities

Elandsfontein/Isando 86 of 96

Page 87: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

38 P29000, 127mm x 76mm m 30

CONDUCTORS

600/1000V grade PVC insulated stranded copper conductors drawn into conduit or

trunking (conduit and trunking elsewhere measured)

39 1.5mm² m 2000

40 2.5mm² m 2200

Draw wire

41 Galvanised draw wire m 2100

APPLIANCES

Appliances complete with cover plates fixed in flush boxes (boxes elsewhere

measured)

Light switches

42 Light switch, one lever No 31

43 Light switch, two lever No 4

Socket outlets

44 3-PIN, 16A, double socket outlet, normal power, white No 72

45 3-PIN, 16A, single socket outlet, normal power, white No 10

46 3-PIN, 16A, single socket outlet, emergency dedicated power, Red No 62

47 3-PIN, 16A, double socket outlet, normal power, white, IP65, surface mounted No 3

48 Data and Telephone outlet, RJ45 and RJ11 No 42

49 HVAC Isolator switch, single phase, 25A, Surface mounted in ceiling space No 22

50 HVAC Isolator switch, single phase, 25A, Wall Surface mounted outdoor, IP65 No 6

51 HVAC Isolator switch, Three phase, 20A, Surface mounted in ceiling space No 10

52 HVAC Isolator switch, Three phase, 100A, Panel mounted No 1

53 Audio and video outlet, 1 x HDMI, 1 x VGA, 1 x speaker, 1 x USB No 2

Surface mounted appliances complete with cover plates and boxes

54 Flush mounted Floor outlet box, PVC No 2

55

Occupancy motion sensor, ceiling recessed mounted, infrared, 360 degree angle, 220V,

500W, 30 minutes time setting No 8

56

Occupancy motion sensor, surface mounted, infrared, 180 degree angle, 220V, 500W, 30

minutes time setting No 10

57 Light day /night sensor No 4

POWERSKIRTING

Three compartment two cover Classic or equal and approved powerskirting, complete

with cover as per the specification (bends, end caps, etc elsewhere measured)

58 Straight length m 200

59 Vertical riser m 20

C2.2 Bills of Quantities

Elandsfontein/Isando 87 of 96

Page 88: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Fittings to three compartment powerskirting

60 End caps No 48

61 45 Degree Bend No 65

62 Internal angles No 45

INTERNAL AND EXTERNAL LUMINAIRES

Supply and install light fittings in ceiling tee's and/or mounted to round boxes in

brickwork including 3m cabtyre and 5amp plugtop and all fixing (round boxes

elsewhere measured)

63 Office light, LED, 35W, 3 600 lumen, 600 x 600mm, recessed in ceiling No 78

64 Bulkhead, LED, 20W, 2 000 lumen, IP65, surface mounted No 52

65 Fluorescent light, LED, 40W, 4 700 lumen, surface mounted No 47

66 Downlight, LED, 20W, 4000K, 2000 lumen, recessed in ceiling No 63

67 Floodlight, LED, 50W, 6 000 lumen, IP65 No

68 High bay light, LED, 322W, wide beam, 37 000 lumen, IP65, mounted at 4,5m FFL No 6

69 Indicating STOP / GO light, 230V LED red and green lamps, wired to door contacts No 10

70 Perimeter light, floodlight, LED, 108W, IP65, 12 800 lumen, 4000k No 28

71

Light pole, Fibre glass reinforced, with steel base plate, 6.9m pole, 6m FFL after installed, for

perimeter lights No 17

72 Emergency battery pack as per manufacturers specifications fitted to light type No

DATA

Data and IT installation and office appliances

73

Allow a budgetary allowance of R1,100,000. 00 (One Million and One Hundred Thousand

Rand) for the supply and installation of a complete data and telephone network, including

office appliances Item 1 R 1 100 000.00

74 HDMI connection and reticulation between power skirting and boardroom screens No

75

CAT 6 cable in sleeves, including accessories and termination (trenches and sleeves

elsewhere measured) m 1000

Optic Fibre

76 Optic fibre cable, Single mode, 6 core cable, including accessories and termination m 600

77 Fibre termination box No 4

ACCESS CONTROL AND CCTV INSTALLATION

Supply and install CCTV Cameras and appliances mounted in accordance with

suppliers specifications

78

Outdoor network bullet camera, 3MP, 1920 x 1080p, triple streams, 2.8-12mm motorized

varifocal lens, array IR leds (50m range), 3DNR, true WDR (120db), audio, alarm in/out, smart

analysis, SD card slot, IP66 No 8

79

Light pole, Fibre glass reinforced, with steel base plate, 4.6m pole, 4m FFL after installed, for

perimeter cameras No 2

80 40 inch HD display screen for camera displays - Guardhouse and Watchroom No 2

C2.2 Bills of Quantities

Elandsfontein/Isando 88 of 96

Page 89: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Cables and accessories

81

CAT 6 cable in sleeves, including accessories and termination (trenches and sleeves

elsewhere measured) m 500

82 Junction box No 3

Sundries

83 Allow for wifi access point systems Item 1

84 Allow for TV satelite, decoder systems, etc Item 1

PUBLIC ADDRESS AND AUDIO SYSTEMS

85 Room audio speaker, 2,5W, round, recessed in ceiling No

86 PA audio speaker, 6W, round, recessed in ceiling No 12

87 PA audio speaker, 3W, round, IP55 rated, recessed in ceiling No 2

88 PA audio speaker, 15W, horn speaker, surface mounted, IP65 No 9

89 Firemans microphone unit No 1

90 Voice Alarm, Mixer amplifier, 240W, 6 Zones, system management No 1

91 Standby, Mixer amplifier, 240W, 6 Zones No 1

92 Speaker cabling m 500

93 Rack, complete No 1

94 Table conference phone microphone module, 360 degree reception, 30m² room size No

95 Gate intercom system No 1

FIRE DETECTION INSTALLATION

Prices to include for supply, transport, delivery to site, testing, installation, labelling and

consumables

96 Smoke detector, surface mounted No 39

97 Heat detector, surface mounted No 3

98 Siren and strobe light attached to detector, surface mounted No 7

99 Red break glass manual alarm panel No 9

100 Main Fire alarm control panel, surface mounted No 1

101 Mimic Fire alarm control panel, surface mounted No 1

102 Fire retardant cable for detectors m 500

Cables and accessories

103

Twisted pair cable, including accessories and termination (trenches and sleeves elsewhere

measured) m 1500

C2.2 Bills of Quantities

Elandsfontein/Isando 89 of 96

Page 90: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

TRENCH EXCAVATIONS

104

Trenching 500mm deep, inclusive of excavation in pickable soil, prescribed fill, compaction

and carting away of surplus material, all in accordance with the engineers specification.

Excavation through 100mm reinforced concrete surface slabs or 35mm asphalt road surfacing,

inclusive of making good. Protect with danger tape m 500

105

Trenching 1000mm deep, inclusive of excavation in pickable soil, prescribed fill, compaction

and carting away of surplus material, all in accordance with the engineers specification.

Excavation through 100mm reinforced concrete surface slabs or 35mm asphalt road surfacing,

inclusive of making good. Protect with danger tape m 100

106 Pole base excavation No 20

MANHOLES AND PRECAST CHANNELS

Manholes and covers

107

Concrete Manholes, size 600mm x 450mm x 600mm deep including excavations, backfilling,

covers, etc No 16

GENERAL ITEMS

Guarantee

108

Allow for a guarantee period of twelve (12) months on the entire electrical installation as per

the specification Item 1

Maintenance

109

Allow for free maintenance during the guarantee period of the electrical installation as per the

specification Item 1

Drawings and manuals

110 Allow for 3 sets of operating and maintenance manuals and as-built as per the specification Item 1

111 Allow for submission of 3 sets of shop drawings as specified Item 1

Labelling and marking

112 Allow for marking and labelling of all the equipment, cables, plugs, etc as per the specification Item 1

Earthing and bonding

113

Allow for earthing and bonding, including earth rods, terminals, junction boxes, copper cabling,

etc as per the specification Item 1

Testing and commissioning

114

Allow for testing and commissioning of the entire electrical installation in accordance with the

Engineer's requirements Item 1

Total Carried Forward to Section Summary

Total Carried Forward to Final Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 90 of 96

Page 91: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION 5

BILL No. 1

MECHANICAL INSTALLATION

SUPPLEMENTARY PREAMBLES

DUCTING AND EQUIPMENT

Ductwork

Where transformations or reducers occur the larger size ductwork has been measured through

the fitting. Descriptions of ductwork shall be deemed to include stiffeners, jointing materials,

sealants, couplers in the running length and access/inspection panels in accordance with the

specification

Air Diffusion

Descriptions of air terminals, grilles, louvres and the like shall be deemed to include necks,

frames, supports and flexible connections

Fans

Descriptions of fan assemblies shall be deemed to include supports from the structure, flexible

or other connections to ductwork, vibration isolation mountings and airtight inspection doors

Fan coil units, fan air terminals and fan heaters

Descriptions of fan coil units, fan air terminals and fan heaters shall be deemed to include

connection points for water, air and electrical, air grilles, dust trays, condensate trays and

vibration isolation mountings. Flexible ducting, flexible hose and connecting cables for

connecting these units to each other or to water piping and electrical supply are separately

measured

Major equipment

Descriptions of major equipment such as chillers, air handling units and the like shall be

deemed to include connections to water, air and electrical supply and/or discharge points,

supports, bearers, vibration isolation mountings, filters, insulation, inspection ladders and

gangways, access doors and panels, painting, etc as specified

PIPING AND PUMPS

Piping

All pipe diameters are nominal internal unless otherwise stated where fittings have reducing

ends or branches they are described as "reducing". In the case of pipes with diameters not

exceeding 60mm only the largest end or branch size is given. Should the contractor wish to

use other fittings and bushes or reducers he may do so on the understanding that no claim in

this regard will be entertained. In the case of pipes with diameters exceeding 60mm all sizes

are given and no claim for extra bushes, reducers, etc will be entertained

Fixing of pipes

Unless specifically otherwise stated, descriptions of pipes shall be deemed to include fixing to

walls etc, casting in, building in or suspending not exceeding 1m below suspension level

Pump sets

Descriptions of pumps shall be deemed to include connections to water and electrical supply

and/or discharge points, vibration isolation mountings, insulation, drip trays with outlets,

pressure gauges, etc

C2.2 Bills of Quantities

Elandsfontein/Isando 91 of 96

Page 92: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Valves

Descriptions of valves shall be deemed to include flanged or screwed connections to piping,

reducers, supports, etc

Insulation

Descriptions of insulation shall be deemed to include priming the piping with zinc chromate

primer before the insulation is applied, painting the insulation when completed and applying

vapour barrier where specified

Measuring note

Electrical work integral to the mechanical installation was measured under the Electrical

Installation trade

PRELIMINARY AND GENERAL - MECHANICAL SUB CONTRACTOR

1 Registration as contractor Item 1

2 Site establishment and site supervision by accredited person including travel, subsistence, etc. Item 1

3

Quality assurance and provision of a quality control inspector reporting to the Electrical

Engineer for the duration of the contract Item 1

4 Storage of material, containers and security Item 1

5 Contractors insurance Item 1

6 Health & Safety Plan for Project, and Safety Equipment for Workers Item 1

7

Transport of material for storage including installation and disposal of components. The

contractor to provide all required scaffolding, cherry picker, personnel/ operators, ladders,

tools, etc as required. Item 1

AIR CONDITIONING, VENTILATION AND REFRIGERATION

EXTRACT DUCTWORK

Galvanised rigid sheet metal spiral ducting including supports

Category 4 ductwork

Supply and install spiral ducting as per relevant drawings. Duct work to be joint and

sealed as per mechanical works specification. Discharges off main supply branch to be

flexible ducting

Rate to include cutting of duct lengths, connection of duct work, support of duct work, welding

of fittings where necessary and connection to inline ducted extraction fans.

8 100mm Diameter m 18.6

9 150mm Diameter m 40.2

10 200mm Diameter m 20.9

11 300mm Diameter m 40

12 350mm Diameter m 13.8

13 400mm Diameter m 38.2

Extra over Category 4 galvanised sheet metal low pressure ductwork for

14 Reducer, radius bend, square bend, transformation, spigot, branch or tee No 48

C2.2 Bills of Quantities

Elandsfontein/Isando 92 of 96

Page 93: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

DIFFUSERS, GRILLES, ETC

POWDER EPOXY COATED ALUMINIUM EXTRACT, TRANSFER AND RETURN AIR

GRILLES

Non-vision wall grilles

Approved supplier

Supply and install non-vision wall grilles as per relevant drawings suitable for internal walls.

Grilles to be installed in accordance with manufacturers guidelines.

Rate to include breaking into existing wall and installation of grille into void.

15 100 x 700mm Air supply grille, 135 L/s @ 25Pa No 1

Adjustable louvres

Approved supplier

Supply and install adjustable louvres as per relevant drawings suitable for internal walls.

Grilles to be installed in accordance with manufacturers guidelines.

Rate to include breaking into existing wall and installation of grille into void.

16 1000 x 400mm High No 4

Air-diffusers

Approved supplier

Supply and install air diffusers as per relevant drawings. Diffusers to be installed in accordance

with manufacturers guidelines.

Rate to include filters, breaking into existing structure and installation of diffuser into void.

17 125mm Diameter diffuser, 29L/s No 3

18 125mm Diameter diffuser, 34L/s No 2

19 125mm Diameter diffuser, 44L/s No 4

20 125mm Diameter diffuser, 50L/s No 6

21 125mm Diameter diffuser, 90L/s No 4

EQUIPMENT

Extraction Fans

Approved supplier

Supply and install roof mounted inline ducted extraction fans as per relevant drawings.

Fans to be installed horizontally at roof level with connection to electrical services and

integration into BMS system where relevant for remote control.

Rate to include supply, install, commissioning, connection to duct work and integration with

BMS system.

22 1100m3/H Plate mounted axial extraction fans - 0,09kW @ 400V No 4

23 Wall mounted extraction fan connected to light switch - 135 L/s @ 25Pa static pressure No 1

24 Ceiling mounted extraction fan - 29 L/s @ 50Pa 16W @ 240V No 1

C2.2 Bills of Quantities

Elandsfontein/Isando 93 of 96

Page 94: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

Air handling units

Approved supplier

Supply and install air handling units in ceiling void as per relevant drawings.

Rate to include supply, install, commissioning, connection to duct work and integration with

BMS system.

25 Ducted air handling unit with cross flow heat recovery, 60L/s @ 15Pa, 29W @ 240V No 1

26 Ducted air handling unit with cross flow heat recovery, 150L/s @ 15Pa, 210W @ 240V No 1

27 Ducted air handling unit with cross flow heat recovery, 520L/s @ 80Pa, 210W @ 240V No 1

AIR CONDITIONING UNITS AND DE-HUMIDIFIERS

Approved supplier

Supply and install VRV compatible indoor units in accordance with mechanical works

specification as per relevant drawings. Units to be supported from slab with connection

to electrical services and integration into BMS system where relevant for remote

control.

Rate to include supports, routing and fixing of refrigerant piping and drainage along cable tray,

connection to electrical supply, connection to outdoor VRV unit and integration to BMS

system.

28 1,7kW VRV cooling capacity wall mounted indoor unit, 0,025kW @ 400V No 1

29 2,8kW VRV cooling capacity wall mounted indoor unit, 0,034kW @ 240V No 3

30 3,6kW VRV cooling capacity wall mounted indoor unit, 0,035kW @ 240V No 4

31 4,5kW VRV cooling capacity wall mounted indoor unit, 0,02kW @ 400V No 2

32 5,6kW VRV cooling capacity wall mounted indoor unit, 0,039kW @ 400V No 2

33 7,1kW VRV cooling capacity wall mounted indoor unit, 0,06kW @ 400V No 1

34 9kW VRV cooling capacity wall mounted indoor unit, 0,092kW @ 400V No 1

35 11,2kW VRV cooling capacity ceiling mounted cassette indoor unit, 0,115kW @ 240V No 3

36 14kW VRV cooling capacity ceiling mounted cassette indoor unit, 0,186kW @ 240V No 1

37

111,5kW Variable refrigerant volume cooling capacity, heat recovery, heat pump combination

for simultaneous cooling and heating, 51,7 A @ 400V No 1

GENERAL

38 Testing and commissioning the air conditioning, ventilation and refrigeration installation Item 1

39

Provision of as built drawings, manuals and operative training (refer to additional preamble

under "Kitchen Equipment" for additional information on the provision of manuals and price

accordingly") Item 1

40 Certificate of compliance in terms of the Occupational and Health Safety Act 1993 Item 1

AIR COMPRESSORS

41

Supply and install bottled air compressors to deliver high pressure breathing air for use by fire

fighting personnel as per mechanical works specification - 600L/m No 2

C2.2 Bills of Quantities

Elandsfontein/Isando 94 of 96

Page 95: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

HIGH PRESSURE WASHER

42

Allow a provisional sum of R 110,000.00 (One Hundred and Ten Thousand Rand) for the

supply and installation of two wall mounted high pressure washers as directed by the Principal

Agent Item 1 R 110 000.00

KITCHEN APPLIANCES

43

Allow a provisional sum of R 75,000.00 (Seventy-five Thousand Rand) for the supply and

installation of kitchen appliances as directed by the Principal Agent Item 1 R 75 000.00

FUEL TANKS

44

Allow a provisional sum of R 65,000.00 (Sixty-five Thousand Rand) for the supply and

installation of fuel tanks and fuel dispensing pumps Item 1 R 65 000.00

POTABLE WATER TANK AND PUMP STATION

45

Allow a provisional sum of R 1,000,000.00 (One Million Rand) for the supply and installation of

an elevated water tank and pumps complete Item 1 R 1 000 000.00

Total Carried to Section Summary

Total Carried to Final Summary

C2.2 Bills of Quantities

Elandsfontein/Isando 95 of 96

Page 96: C2.2 BILLS OF QUANTITIES - Ekurhuleni 02 - 2017 bill of... · C2.2 Bills of Quantities Elandsfontein/Isando 8 of 96. CONTRACTUAL AGREEMENT (A42) 42.1 Agreement Clause applicable 42.2

SECTION No. 5

BILL No. 1

BUDGETARY ALLOWANCES

Work covered by the following budgetary allowance(s) shall be executed by the Contractor,

measured on completion thereof and valued at scheduled rates where applicable by the

Quantity Surveyor in terms of Clause 32 of the Principle Building Agreement

1

Provide the amount of R100,000.00 (One Hundred Thousand Rand) for a professional fee for

the interior decorator Item 1 R 100 000.00

2

Provide the amount of R200,000.00 (Two Hundred Thousand Rand) for builders work in

connection with specialist installations Item 1 R 200 000.00

3 Provide the amount of R300,000.00 (Three Hundred Thousand Rand) for connection fees, etc Item 1 R 300 000.00

Total Carried Forward To Final Summary

FINAL SUMMARY

Section 1: Preliminaries and General

Section 2: Building Works

Section 3: Site Services

Section 4: Electrical installation

Section 5: Mechanical installation

Section 6: Budgetary Allowances

SUB TOTAL (EXCLUDING VAT)

Contingencies

Allow 10% (Ten Percent) for Contingencies to be used as directed and deducted in whole or in

part if not required Item 10%

SUB TOTAL (EXCLUDING VAT)

ADD 14% VALUE ADDED TAX TAX 14%

TOTAL (INCLUDING VAT)

C2.2 Bills of Quantities