INDEX OF DRAWINGS
TITLE PAGE001
003
CHANGES TO THIS PLAN/DRAWING SET REQUIRE WRITTEN APPROVAL BY FEI.
C:\Users\Diane\Desktop\BT-081 DEC 2015 LFG WORK\DRAWINGS\Sheets 1-2\BT-081-CD-001 (Title Sheet).dwg
NOVEMBER 2015
PREPARED FOR:
BRIDGETON LANDFILL, LLC.
CONSTRUCTION DRAWINGS FOR
DECEMBER 2015 LANDFILL GAS
ENHANCEMENTSBRIDGETON LANDFILL
BRIDGETON, ST. LOUIS COUNTY, MISSOURI
3405 HOLLENBERG DRIVE
BRIDGETON, MO 63044
TEL. (314) 736-5794
FULL SITE PLAN VIEW002
004-005
2015 LFG MODIFICATIONS PLAN VIEW
DETAILS
BRIDGETON LANDFILL, LLC
13570 ST. CHARLES ROCK ROAD
BRIDGETON, MISSOURI 63044
BRIDGETON LANDFILL
DECEMBER 2015
LFG MODIFICATIONS
DRAWING NO.:
APPROVED BY: ALK
NOVEMBER 2015
REVISION DATEPROJECT NUMBER: BT-081 FILE PATH:
FEEZORFULL SITE PLAN VIEW
002
DESIGNED BY: DMK
Feet
0 200 400
CLOSED
DEMOLITION
LANDFILL
WEST
LAKE
OU1(2)WEST LAKE OU2
WEST
LAKE
OU1(1)
LFG
MODIFICATION
LOCATIONS
NORTH
QUARRY
AREA
SOUTH
QUARRY
AREA
BRIDGETON LANDFILL, LLC
13570 ST. CHARLES ROCK ROAD
BRIDGETON, MISSOURI 63044
BRIDGETON LANDFILL
DECEMBER 2015
LFG MODIFICATIONS
DRAWING NO.:
APPROVED BY: ALK
NOVEMBER 2015
REVISION DATEPROJECT NUMBER: BT-081 FILE PATH:
FEEZOR2015 LFG MODIFICATIONS PLAN VIEW
003
Feet
0 100 200
GE
W
LFG EXTRACTION WELL DETAIL
PERFORATED PIPE DETAIL
BRIDGETON LANDFILL, LLC
13570 ST. CHARLES ROCK ROAD
BRIDGETON, MISSOURI 63044
BRIDGETON LANDFILL
DECEMBER 2015
LFG MODIFICATIONS
DRAWING NO.:
APPROVED BY: ALK
NOVEMBER 2015
REVISION DATEPROJECT NUMBER: BT-081 FILE PATH:
FEEZOR 004
GAS WELL DETAILS
DESIGNED BY: BJV
36" Ø
24" Ø
24" °Ø
18" Ø
18" Ø
Flange Adapter
w/ D.I. Backup Ring
Flange Adapter
w/ D.I. Backup Ring
18"Ø
18"Ø
(2) 24"Ø
2" Ø SOLID SDR 11
DROP TUBE W/ OPEN BOTTOM
2"Ø SDR 11 MOLDED 90°
2"Ø SDR 11 PIPE PENETRATION
W/ 316 SS TRANSITION FITTING
AND SUPPORT GUSSET AT EL. OF
LIFTING LUG
HDPE BAFFLE FROM 1" SHEET
(3" ABOVE 24" OUTLETS &
3" BELOW 18" INLETS)
HDPE SHEET BAFFLE
GROUND
36"Ø SUMP
CONDENSATE SUMP 81
36" Ø
24" °Ø
18" Ø
Flange Adapter
w/ D.I. Backup Ring
Flange Adapter
w/ D.I. Backup Ring
HDPE BAFFLE FROM 1" SHEET
(3" ABOVE 24" OUTLET &
3" BELOW 18" INLET)
18"Ø
24"Ø
2" Ø SOLID SDR 11
DROP TUBE W/ OPEN BOTTOM
2"Ø SDR 11 MOLDED 90°
2"Ø SDR 11 PIPE PENETRATION
W/ 316 SS TRANSITION FITTING
AND SUPPORT GUSSET AT EL. OF
LIFTING LUG
HDPE SHEET BAFFLE
GROUND
36"Ø SUMP
CONDENSATE SUMP 31
36" Ø
18" Ø OUTLET
Flange Adapter
w/ D.I. Backup Ring
Flange Adapter
w/ D.I. Backup Ring
18" Ø INLET
18"Ø INLET
2" Ø SOLID SDR 11
DROP TUBE W/ OPEN BOTTOM
2"Ø SDR 11 MOLDED 90°
2"Ø SDR 11 PIPE PENETRATION
W/ 316 SS TRANSITION FITTING
AND SUPPORT GUSSET AT EL. OF
LIFTING LUG
GROUND
36"Ø SUMP
18"Ø OUTLET
CONDENSATE SUMP 32
36" Ø
18" Ø OUTLET
Flange Adapter
w/ D.I. Backup Ring
18" Ø INLET
Flange Adapter
w/ D.I. Backup Ring
18"Ø INLET
2" Ø SOLID SDR 11
DROP TUBE W/ OPEN BOTTOM
2"Ø SDR 11 MOLDED 90°
2"Ø SDR 11 PIPE PENETRATION
W/ 316 SS TRANSITION FITTING
AND SUPPORT GUSSET AT EL. OF
LIFTING LUG
GROUND
36"Ø SUMP
18"Ø OUTLET
CONDENSATE SUMP 33
BRIDGETON LANDFILL, LLC
13570 ST. CHARLES ROCK ROAD
BRIDGETON, MISSOURI 63044
BRIDGETON LANDFILL
DECEMBER 2015
LFG MODIFICATIONS
DRAWING NO.:
APPROVED BY: ALK
NOVEMBER 2015
REVISION DATEPROJECT NUMBER: BT-081 FILE PATH:
FEEZOR 005
CONDENSATE SUMP DETAILS
DESIGNED BY: BJV