SDMEU SensorDisplayMemoryEthernet Unit

Operating and Maintenance Instructions English

Doc.: 3356723 / 2007-07-20

Page 2: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 2BeWa SDMEU 3356723 en.doc 2007-07-20

Trademarks The trademarks of other companies are exclusively used for the products of those companies.

Copyright © 2007 by HYDAC Filtertechnik GmbH all rights reserved All rights reserved. This manual may not be reproduced in part or whole without the explicit written agreement from HYDAC Filtertechnik. Contraventions are liable to compensation.

Exclusion of liability We made every endeavor to ensure the accuracy of the contents of this document. However, errors cannot be ruled out. Consequently, we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors. The content of the manual is checked regularly. We welcome any suggestions for improvements.welcome

All details are subject to technical modifications.

Technical specifications are subject to change without notice.

HYDAC Filtertechnik GmbH

Industriegebiet

D-66280 Sulzbach / Saar

Germany

Phone: ++49 (0) 6897 / 509 – 01

Fax: ++49 (0) 6897 / 509 – 846

Page 3: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 3BeWa SDMEU 3356723 en.doc 2007-07-20

Table of Contents Table of Contents ...................................................................................................................3 Preface ....................................................................................................................................5

Customer Service .................................................................................................................6 Modifications to the Product .................................................................................................6 Warranty ...............................................................................................................................6

1 General Safety Guidelines..............................................................................................8 1.1 Obligations and Liability.................................................................................................8 1.2 Explanation of Symbols and Warnings..........................................................................8

1.2.1 Basic Symbols........................................................................................................9 1.3 Proper/Designated Use .................................................................................................9 1.4 Improper Use.................................................................................................................9 1.5 Informal Safety Precautions ........................................................................................10 1.6 Instructions to Be Followed in the Event of an Emergency .........................................10 1.7 Training and Instruction of Personnel..........................................................................10

2 Packing, Storage ...........................................................................................................11 2.1 Transportation and Packing.........................................................................................11 2.2 Storage ........................................................................................................................11

3 Scope of Delivery ..........................................................................................................11 4 Description: ...................................................................................................................12 5 Installation .....................................................................................................................13 6 Connection ....................................................................................................................14

6.1 Connector cable ..........................................................................................................15 6.1.1 Plugs ....................................................................................................................15 6.1.2 Connector cable ...................................................................................................15 6.1.3 Connector cable ...................................................................................................15

7 Control unit....................................................................................................................16 8 Installation .....................................................................................................................16 9 Operation .......................................................................................................................17

9.1 Keypad ........................................................................................................................17 9.2 Selecting menus and entering values..........................................................................17 9.3 Selecting main and system menus..............................................................................18

9.3.1 Status display .......................................................................................................18 9.3.2 Main menu without password protection ..............................................................19 9.3.3 Main menu with password protection ...................................................................19 9.3.4 System menu .......................................................................................................20

10 Description of the settings...........................................................................................22 10.1 Password protection ....................................................................................................22 10.2 Password setup ...........................................................................................................22

Page 4: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 4BeWa SDMEU 3356723 en.doc 2007-07-20

10.3 Select the scope of the password................................................................................23 10.4 Activating the password...............................................................................................23 10.5 Access with password protection ................................................................................24 10.6 Changing the password and range..............................................................................25 10.7 Password, delete .........................................................................................................25 10.8 Changing the menu language .....................................................................................26 10.9 Setting the date and time.............................................................................................26 10.10 Startup behavior ...................................................................................................27 10.11 Setting the LCD contrast and backlighting ...........................................................27

11 Software Update............................................................................................................28 12 Functions / Menu guide ................................................................................................29

12.1 CS 1000 Menu.............................................................................................................29 12.2 Sensor status CS 1000................................................................................................29 12.3 AS 1000 menu.............................................................................................................30 12.4 HLB (HYDACLab)........................................................................................................30

12.4.1 HLB Sensor status: ..............................................................................................30 12.5 Service menu...............................................................................................................30

12.5.1 Data logging .........................................................................................................31 12.5.1.1 Data logging status .......................................................................................31

12.5.2 Units .....................................................................................................................31 12.5.2.1 Status CS / HLB ............................................................................................31 12.5.2.2 Status AS ......................................................................................................31

12.5.3 Information ...........................................................................................................31 12.6 Changeover display mode automatic /manual ............................................................32

13 Data format data logger+..............................................................................................33 14 OPC Variables / OPC Server ........................................................................................35 15 Disposal / Recycling .....................................................................................................36 16 Sensor settings .............................................................................................................37 17 Technical details ...........................................................................................................37 18 Customer Service..........................................................................................................38

Page 5: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 5BeWa SDMEU 3356723 en.doc 2007-07-20

Preface

For you,

as owner of a product manufactured by us, we have produced this manual, comprising the most important instructions for its operation and maintenance.

It is intended to help you become acquainted with the proper/designated use of the product and to use it properly. You should keep it in the vicinity of the product so it is always at your fingertips.

Sometimes the information contained in this documentation cannot always keep up with changes made to the product as we attach considerable importance to keeping our products cutting-edge. Consequently, there might be deviations in technical details, illustrations and dimensions.

In these cases we go to every effort to keep your documentation current by sending you updates (see “What’s New”).

But we need your help. Please make sure that you incorporate the updates in your documentation and that non-current sections are removed.

If you discover errors while reading the documentation or have suggestions or other useful information, please don’t hesitate to contact us:

HYDAC Filtertechnik GmbH SVFI, Technical Documentation Department Postfach 12 51 66273 Sulzbach / Saar, Germany

Fax: ++49 (0) 6897 509 846 Email: [email protected]

The editor would welcome your involvement.

Our motto: “Putting experience into practice”

Page 6: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 6BeWa SDMEU 3356723 en.doc 2007-07-20

Customer Service If you have any questions, suggestions, or encounter any problems of a technical nature, please contact us. When contacting us, please always include the model/type designation and article no. of the product:

Fax: ++49 (0) 6897 509 846 Email: [email protected]

Modifications to the Product We would like to point out that changes to the product (e.g. purchasing options, etc.) may result in the information in the operating instructions no longer being completely accurate or sufficient.

When making modifications or performing repair work to components affecting the safety of the product, the product may not be put back into operation until it has been examined and released by a HYDAC representative.

Please notify us immediately of any modifications made to the product whether by you or a third party.

Warranty For the warranty provided by us, please refer to the General Conditions of Sale and Delivery of HYDAC Filtertechnik GmbH.

They are available at: www.hydac.com Legal information.

Page 7: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 7BeWa SDMEU 3356723 en.doc 2007-07-20

... and now for a few tips on using this document..

The following example shows you how you can access the information you are looking for quick and easy.

WHAT do I want to know?

WHERE can I find the information I’m looking for?

The documentation is subdivided into chapters and sections.

Look for the table of contents.

Skim the boldfaced section headings.

HOW can I find the section and page I’m looking for?

Page through the operating instructions, keeping your eyes focused on the lower right corner.

As soon as you see the page number you are looking for, stop paging.

The product description heading is featured in the upper right corner of each page.

The documentation number/edition and index are featured in the lower left corner of each page and on the cover sheet of the instructions. This information features the following format:

The documentation no. is a p/no. which is used to order the instructions. The index is supplemented every time the instructions are revised or changed.

Please note that the method described above of locating specific information does not release you from your responsibility for carefully reading the entire manual prior to starting the unit up for the first time and carefully rereading the manual at regular intervals later on.

Productdescription or Chapter heading

Page no. Edition date of

h t / ti

Documentation no. Index

BeWa Product 12345678a en

Page 8: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 8BeWa SDMEU 3356723 en.doc 2007-07-20

1 General Safety Guidelines These operating instructions contain the key instructions for properly and safely operating the SDMEU.

1.1 Obligations and Liability • The basic prerequisite for the safe and proper handling and operation of the SDMEU is

knowledge of the safety instructions and warnings.

• These operating instructions in general, and the safety precautions in particular, are to be adhered by all those who work with the SDMEU.

• Adherence is to be maintained to pertinent accident prevention regulations applicable at the site where the product is used.

• The safety precautions listed herein are limited solely to using the SDMEU.

The SDMEU has been designed and constructed in accordance with the current state of the art and recognized safety regulations. Nevertheless, hazards may be posed to the life and limb of the individual using the unit or to third parties. Risk of damage may be posed to the unit or other equipment and property. The SDMEU is only to be used as follows

• solely for its designated use

• only when in a safe, perfect condition

• Any faults or malfunctions which might impair safety are to be properly repaired or remedied immediately.

Our General Terms and Conditions apply. They are made available to the owner upon concluding purchase of the unit at the latest. Any and all warranty and liability claims for personal injuries and damage to property shall be excluded in the event they are attributable to one or more of the following causes:

• Improper use of the SDMEU or use deviating from its designated use

• Improper assembly, installation, commissioning, operation and maintenance of the SDMEU

• Operating the SDMEU when the system equipment or systems are defective

• Modifications to the SDMEU made by the user or purchaser

• Improper monitoring of unit components subject to wear and tear

• Improperly performed repair work

1.2 Explanation of Symbols and Warnings The following designations and symbols are used in this manual to designate hazards, etc.:

Page 9: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 9BeWa SDMEU 3356723 en.doc 2007-07-20

1.2.1 Basic Symbols

This symbol designates safety instructions whose non-observance may pose a hazard to individuals.

This symbol designates safety instructions whose non-observance may result in the injury of individuals by electric shock.

This symbol provides important instructions and tips for the proper handling and operation of the SDMEU. Non-adherence to these instructions may result in damage to the SDMEU or in damage to its immediate surroundings.

This symbol designates tips for usage and other particularly useful information. This information helps you to optimally utilize all the features offered by your SDMEU.

1.3 Proper/Designated Use The Sensor Display Memory Unit (SDMEU) was developed for the continuous monitoring of particulate contamination in hydraulic systems.

Analyzing the type, size and quantity of contamination enables quality standards to be verified and documented, and the requisite optimization measures to be implemented.

Any other use shall be deemed to be improper and not in keeping with the product's designated use.

Proper or designated use of the product extends to the following:

• Maintenance of fluids in hydraulic and lubrication systems

• Maintaining adherence to all the instructions contained herein.

1.4 Improper Use • Any use deviating from the proper/designated use described above is prohibited.

• Improper use may result in hazard to life and limb.

• Example of improper use:

improper connection of the SDMEU voltage and sensor cables.

Page 10: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 10BeWa SDMEU 3356723 en.doc 2007-07-20

1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the SDMEU.

• Apart from the operating instructions, any and all general and local regulations pertaining to accident prevention and environmental protection are to be made available and observance to be maintained to them.

1.6 Instructions to Be Followed in the Event of an Emergency

In the event of an emergency, immediately disconnect the SDMEU from the power supply!

1.7 Training and Instruction of Personnel • The SDMEU may only be operated by properly trained and instructed personnel.

• The areas of responsibility of your staff must be established in a clear-cut manner.

• Staff undergoing training may not use the SDMEU unless supervised by an experienced staff member.

Individuals Activity

Individuals undergoing

training

Individuals with technical

training/engineering background

Electrician Supervisor with the

appropriate authority

Packing Transportation X X X

Commissioning X X X

Operation X X X X

Troubleshooting / locating the source of malfunction

X X X

Troubleshooting, mechanical problem X X

Troubleshooting, electrical problem X X

Maintenance X X X X

Repair work X

Decommissioning

Storage X X X X

Page 11: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 11BeWa SDMEU 3356723 en.doc 2007-07-20

2 Packing, Storage

2.1 Transportation and Packing The SDMEU comes packed in a cardboard box.

Unpack the unit and check it for damage in transit. Report any damage to the forwarding agent immediately.immediately

2.2 Storage Make sure to store the SDMEU in a clean, dry place, in the original packing, if possible. Do not remove the packing until you are ready to install the unit.

3 Scope of Delivery SDMEU comes packed and factory-assembled. Before commissioning the SDMEU, check the content of the package to make sure everything is present.

The following items are supplied:

Qty. Designation

1 pc. SensorDisplayMemoryEthernet Unit

1 pc. Voltage cable for the SDMEU, L=5m, (ZBE 08-05)

4 pc. Wall fixing tabs for mounting the housing

1 pc. SDMEU Operating and Maintenance Instructions (this document)

Page 12: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 12BeWa SDMEU 3356723 en.doc 2007-07-20

4 Description: The Sensor Display Memory Ethernet Unit SDMEU is a small control unit for saving measured values on an MMC memory card.

The following fluid sensors can be connected directly:

• ContaminationSensor CS 1000

• AquaSensor AS 1000

• HYDACLab

The display shows the fluctuating measured values of the connected sensors.

The measured values are saved as *.csv files every 60 seconds (a 128 MB memory card records ca. 3 years' worth of data).

For further processing and evaluation, the data can simply be transferred to Office applications, e.g. MS Excel.

Uses for the SDMEU include:

• Storage of data from fluid monitoring in the field.

• Test installation to validate sensors

Advantages offered by the SDMEU unit:

• Cost-effective, easy-to-install solution

• Simple processing and evaluation with MS Excel

• Ethernet / TCP/IP interface for open communication and OPC servers

• Program restarts independently after a voltage loss

Page 13: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 13BeWa SDMEU 3356723 en.doc 2007-07-20

5 Installation The SDMEU comes packed with 4 wall fixing tabs. These are used to install the housing on a flat surface, such as a wall or switch cabinet..

Page 14: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 14BeWa SDMEU 3356723 en.doc 2007-07-20

6 Connection The SDMEU comes packed with a l=5m voltage cable. Attach this cable according to the following figure.

The sensor connections are clearly defined, so the sensors must be connected to the SDMEU according to the following figure.

Page 15: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 15BeWa SDMEU 3356723 en.doc 2007-07-20

6.1 Connector cable The following plugs and cables are available as accessories.

6.1.1 Plugs

Part no.

Connector female with screw clamp,

screened 6049128

Connector female with screw clamp,

screened ZBE 08 6006786

Connector female with screw clamp,

screened ZBE 44 3281243

Connector female with screw clamp,

screened ZBE0P 6055444

6.1.2 Connector cable

Connector female ↔ Cable ending open Length Part no.

↔ 2 m ZBE 08-02 6006792

↔ + Shield 2 m ZBE 08S-02 6019455

↔ 5 m ZBE 08-05 6006791

↔ + Shield 5 m ZBE 08S-05 6019456

↔ + Shield 10 m ZBE 08S-10 6023102

↔ + Shield 30 m ZBE 08S-30 6035063

6.1.3 Connector cable Connector female ↔ Plug (male) Length Part no.

↔ 5 m ZBE 43-05 3281240

↔ 2 m ZBE 30-02 6040851

↔ 3 m ZBE 30-03 6053924

↔ 5 m ZBE 30-05 6040852

Page 16: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 16BeWa SDMEU 3356723 en.doc 2007-07-20

7 Control unit The core of the SDMEU is the easyControl unit from the Moeller company. It is composed of the following parts:

- easyControl control unit EC4P-222-MTAD1

- Memory module for MMC cards EU4A-MEM-CARD1

- Memory card RS-MMC 128 MB industrial

The control unit includes a 4-line text display with 16 figures per line, and has a real-time clock that will continue to record for at least 72 hours after a voltage loss.

The following are used by the INLETS/OUTLETS and interfaces of the control unit:

- Analog INPUT

• 1x CS1000 (cleanliness class)

• 1x HLB (changes in condition)

• 2x AS1000 – (1x temperature / 1x saturation)

- Ethernet interface (RJ45) provides access to the OPC server. The cover plate of the SDMEU must be removed during use.

For security reasons, the project and parameters relevant to the control unit are also saved on the memory card. Additionally, the memory card serves as a memory device for the data logger function.

8 Installation In the availability status, the project is located on the control unit. The application starts automatically when the power supply is switched on.

During the initial installation or in the case of a longer service life without power, the system clock should be checked and reset if necessary.

The system clock is checked when the program starts. If this times out, the following message appears on the display: „SET CLOCK -> Reboot system.” To set the system clock, first press the ESC to switch to the main menu. Set the hour and date by pressing the ALT button several times (see Setting the system clock, chapter 10.9).

The installation phase lasts ca. 105 seconds and appears on the start page as a % specification.

The sensors are connected to the M12-unit plug on the underside of the SDMEU.

To connect a CS 1000 to the SDMEU, you must first set the analog OUTPUT signal to HDA.ISO.

For all sensors, the SDMEU requires a 4-20mA signal for analog INPUT (no CS 1000 with a voltage signal!).

When using the SDMEU as a data logger, the memory card must be correctly inserted. This will show up on the display as "MC." To check this when the program is running, press the "ESC" button to switch to the main menu.

Page 17: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 17BeWa SDMEU 3356723 en.doc 2007-07-20

9 Operation The following chapter describes the operation of the buttons and the display on the front plate.

9.1 Keypad

DEL Delete or return to applications program from main menu

ALT Special function, status display

Cursor buttons ▲ ▼ ◄ ►: Move cursor Select menu items Set numbers and values

OK Next menu level, save entry

ESC Previous menu level, cancel

9.2 Selecting menus and entering values DEL

and ALT

OK

ESC

Call up system functions

Move to next menu level Call menu item Activate, change, save entry

Move to previous menu level Cancel entries since last OK

▲ Change menu item

♣▼ Change value, change place

◄► P-button function

▲ Input P1 ► Input P2

▼ Input P3 ◄ Input P4

Page 18: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 18BeWa SDMEU 3356723 en.doc 2007-07-20

9.3 Selecting main and system menus 9.3.1 Status display

Page 19: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 19BeWa SDMEU 3356723 en.doc 2007-07-20

9.3.2 Main menu without password protection

9.3.3 Main menu with password protection

Page 20: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 20BeWa SDMEU 3356723 en.doc 2007-07-20

9.3.4 System menu

Page 21: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 21BeWa SDMEU 3356723 en.doc 2007-07-20

Page 22: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 22BeWa SDMEU 3356723 en.doc 2007-07-20

10 Description of the settings Settings are all changed using the operating elements on the control unit.

10.1 Password protection You can protect access to the main menu and system menu, the clock setting and the operating mode (RUN/STOP) with a password. Choose <Security l Range> for the individual setting options.

The system menu is always protected when a password is activated.

The password consists of a value between 000001 and 999999.

Clear a password with the number combination of 000000.

10.2 Password setup A password can be set in the system menu in either the RUN or STOP mode. You cannot change to the system menu if a password is already activated.

► Press DEL and ALT to call up the system menu.

► Select the menu option SECURITY to enter the password.

► Press the OK button and move to the password menu.

► Press OK again for the password entry mode.

Six dashes will appear if no password is entered: No password present.

► Press OK, and six zeroes will appear

► Set the password using the cursor button:

- ◄ ►:Select position in the password,

- ▲ ▼ Set a value between 0 and 9.

► Save the new password by pressing OK.

Press OK to exit the password menu and press ESC and ▼ to the RANGE menu...

The scope of the password has not yet been defined. The password is now valid but not yet activated.

ENTER PASSWORD

_______

ENTER PASSWORD

000042

Page 23: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 23BeWa SDMEU 3356723 en.doc 2007-07-20

10.3 Select the scope of the password ► Press the OK button.

► Select the function or menu to be protected.

► Press OK to protect the function or menu (checked box = protected).

The password protects the program by default. At least one function or one menu must be protected.

PROGRAM: The PROGRAM menu is protected.

• CLOCK: Date and time are protected by the password.

• OPERATING MODE: The toggling of the RUN or STOP program is protected.

10.4 Activating the password You can activate an existing password in four different ways:

• Automatically when the control unit restarts.

• Automatically after the program is loaded.

• Automatically if no telegram was sent to the computer interface 30 minutes after the password was entered.

• Via the password menu.

► Press DEL and ALT to call up the system menu.

► Open the password menu via the SECURITY menu...

The password menu is only displayed if a password is present.

The password protects the program by default.

Make note of the password before activating it. If you forget the password, you will not be able to access the system menu.

► Select ACTIVATE PW and press OK.

The password is now activated. The status display is activated.

You must enter the password before you can access a protected function, a protected menu or the system menu.

PROGRAM

CLOCK

MODE

CHANGE PW

ACTIVATE

Page 24: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 24BeWa SDMEU 3356723 en.doc 2007-07-20

10.5 Access with password protection Password protection is deactivated after the password is entered. You can reactivate the password later using the password menu or by switching the power supply off and the on again.

► Press OK to switch to the main menu.

The password entry will flash.

► Press OK to call up the password entry screen.

If the main menu shows PROGRAM instead of PASSWORD..., this means that password protection is not activated.

The password entry field is shown.

► Set the password using the cursor button.

► Confirm with OK.

If the password entry is correct, the status display is reactivated.

The menu item PROGRAM is enabled.

The system menu is also accessible.

PASSWORD

STOP RUN

PASSWORD

SET CLOCK

ENTER PASSWORD

XXXXX

PROGRAM

STOP

PARAMETERS

SET CLOCK

Page 25: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 25BeWa SDMEU 3356723 en.doc 2007-07-20

10.6 Changing the password and range ► Enter your password.

► Call up the system menu with DEL and ALT.

► Open the password menu using the menu item SECURITY and PASSWORD...

The entry CHANGE PW will flash.

This menu is only displayed if a password is present.

► Press OK for the password entry field.

► Press OK to move to the 6-digit entry field.

► The current password will be displayed.

► Change the six password digits with the cursor buttons.

► Confirm with OK.

Press ESC to exit the security menu.

10.7 Password, delete Use the number combination of 000000 to clear a password.

Six dashes will appear if no password is entered.

Password incorrect or no longer known Have you entered an incorrect password?

► Re-enter the password.

This can be repeated as many times as require!

Pressing ESC returns you to the start menu.

If you forget the password, you can only call up the browser command "factoryset." The password, user program, and boot project will be deleted and the command unit will be reinitialized with the default parameters. See section on "Reset," page 44.

CHANGE PW

ACTIVATE

ENTER PASSWORD

XXXXX

ENTER PASSWORD

100005

ENTER PASSWORD

______

ENTER PASSWORD

XXXXX

Page 26: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 26BeWa SDMEU 3356723 en.doc 2007-07-20

10.8 Changing the menu language You can set the menu languages German and English using the system menu.

The language option is only available if the control unit is not protected by a password.

► Press DEL and ALT to call up the system menu.

► To change the menu language, select MENU LANGUAGE .

The option ENGLISH is displayed.

► Select the new menu language with ▲ or ▼.

► Confirm with OK. Enter a check mark next to "language".

► Exit the menu with ESC.

The new menu language is activated.

Press ESC to return to the status display.

10.9 Setting the date and time The units are provided with a real-time clock with date and time. During the first commissioning, set the hour, minute, day, month, and year.

► Select SET CLOCK in the main menu.

The clock setting menu will flash.

► Select SET CLOCK:

► Enter the values for hour, day, month, and year.

► Press OK to access the entry mode.

– ◄► Select location.

– ▲▼ Change the value.

– OK Save date and time.

– ESC Keep previous setting.

Press ESC to leave the clock setting display.

ENGLISH

GERMAN

SET CLOCK

HH:MM 1012

TTMM 2205

YEAR 2007

Page 27: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 27BeWa SDMEU 3356723 en.doc 2007-07-20

10.10 Startup behavior Setting the startup behavior The following startup options can be set using the menu.

• STOP

• WARM START

• COLD START (factory set)

► Switch to the system menu.

If the control unit is protected by a password, the system menu can only be accessed after entering the password (see "Access with password protection," page 36).

► Set the startup behavior.

10.11 Setting the LCD contrast and backlighting The background lighting of the LCD display can be switched off. The display contrast can be set to one of 5 levels. The display is not required during operation. The backlighting is only required during maintenance and when texts are being displayed.

► Switch to the system menu.

If the control unit is protected by a password, the system menu can only be accessed after entering the password, See "Access with password protection," page 36.

► Select the SYSTEM menu.

► Confirm with the OK button.

► Select the DISPLAY menu with the cursor keys ▲ and ▼ and confirm with OK.

The menus for setting the contrast and backlighting are displayed.

► Press OK to access contrast entry mode.

Using the cursor buttons ▲ and ▼, change the contrast to a value between 2 and +2.

► Select your setting.

► Confirm the setting with the OK button.

The contrast setting remains the same until you change it.

► Switch to the LIGHTING menu using the cursor buttons ▲ and ▼.

► Press the OK button.

SAFETY

SYSTEM

STARTING

PARAMETERS

RESTART

DISPLAY

FACTORY SET

CONTRAST 0

LIGHTING V

CONTRAST 1

LIGHTING V

CONTRAST 1

LIGHTING

Page 28: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 28BeWa SDMEU 3356723 en.doc 2007-07-20

► The background lighting is deactivated.

► If you want to reactivate the background lighting, press the OK button.

► The check mark ✔ shows that the background lighting is activated.

The basic factory setting is as follows:

The contrast is at the setting 0. The background lighting is constantly activated. Menu setting: LIGHTING ✔

11 Software Update If the program has been deleted (see main menu "Control unit"), the program is still saved on the memory card and can be loaded automatically by restarting the system. You can also carry out a software update in this way.

CONTRAST 1

LIGHTING V

Page 29: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 29BeWa SDMEU 3356723 en.doc 2007-07-20

12 Functions / Menu guide The program is divided into the following submenus:

- Start page

- CS 1000 (ContaminationSensor)

- AS 1000 (AquaSensor)

- HLB (HYDACLab)

- Service menu - Datalogging - Units - Information

The sensor data is automatically displayed in 5 second intervals.

Press the OK button to switch between manual (using cursors ◄►) and automatic display.

You can find more detailed information on the individual menu pages in the corresponding chapters.

12.1 CS 1000 Menu Display of the current measured values and of the unit status

CS 1000 ISO: = ISO-classes for 4 / 6 / 14 / 21 µm channel State: = Sensor status CS 1000 (see chapter: 12.2)

12.2 Sensor status CS 1000 - "Undefined": error in the evaluation of the status signal

- "OK...": CS is functioning without errors

- "Error...": Unit error / CS not ready

- "Flow 2 Low": Flow too low

- „ISO <9<8<7“: Flow too high

- "No value": no measured value (flow undefined)

Page 30: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 30BeWa SDMEU 3356723 en.doc 2007-07-20

12.3 AS 1000 menu Display of the current measured values

AS 1000 Sat [%]: = Water saturation in % T [°C]: = Temperature in °C

12.4 HLB (HYDACLab) Display of the current measured values and of the unit status

V = rel. Change of viscosity in % DK = relative change in dielectric constant value in % Sat = Water saturation degree in % T = Temperature in °C State = Sensor status (see chapter 12.4.1)

12.4.1 HLB Sensor status:

- "OK...": HLB is functioning without errors

- "Undefined": error in the evaluation of the status signal

- „Reference“: Reference phase

- „Operating“: Operating phase

- „OutOfRange“: oil status not plausible

- „Error“: Internal error

12.5 Service menu The selected menu item flashes in the service menu. Select the next menu item with the cursor buttons ▲▼ and press OK.

Exit the service menu or return to the sensor data display with DEL.

You cannot switch from the service menu to the control unit menu. The ESC button is blocked.

Page 31: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 31BeWa SDMEU 3356723 en.doc 2007-07-20

12.5.1 Data logging Display status, time, and data size

State = Status at last storage (see chapter 12.5.1.1) Time [s] = remaining time until next storage

(storing interval of 60 seconds) Size = Specification of data size in [kB] or [MB]

12.5.1.1 Data logging status

- „OK…“: Memory card present

- „No disc“: No memory card present

- „Disc FULL“: Memory card full

- „Error“: Other data writing errors.

The MMC card can be removed and reinserted during operation. If no card is inserted during data storage, this data is lost. When the card is reinserted, the data that follows is added on to the existing data. If a memory card was not present during a measurement, this can be recognized by a time gap in the data.

12.5.2 Units Automatic scanning of the input and display of the connected sensors or the current scan phase for each individual sensor.

CS: = CS 1000 (ContaminationSensor) AS: = AS 1000 (AquaSensor) HLB: = HYDACLab

12.5.2.1 Status CS / HLB - „No sensor“: Sensor is not attached, broken cable

- „Sync…“: Synchronizing, recognition of waiting time between transfer of measured values (HDA.ISO Signal)

- „Sync…OK“: Start impulse recognized, begin transfer of measured values (HDA.ISO Signal)

- „Read…“: Reading measured values (HDA.ISO Signal)

12.5.2.2 Status AS - „No sensor“: Sensor is not attached, broken cable

- „Read…“: Reading measured values

12.5.3 Information

Page 32: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 32BeWa SDMEU 3356723 en.doc 2007-07-20

This information appears after switching on the SDMEU or in the service menu under the menu item "Information."

Product name

Software: Version number

Contact:(WWW)

12.6 Changeover display mode automatic /manual

While the program is running, you can switch between the manual and automatic display of pages by pressing the "OK" button.

During the changeover, the set mode appears briefly on the display.

In automatic mode, the individual windows are displayed for 5 seconds. The sensor menus are skipped when a sensor and measured values are no longer present.

If the SDMEU finds no sensor, or if no sensor has been attached, this message will appear on the display.

Page 33: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 33BeWa SDMEU 3356723 en.doc 2007-07-20

13 Data format data logger+ The measured values are deposited on a memory card in a text folder in CSV format (separated with a comma). This data format can be opened and edited further in different user programs, e.g. MS Excel.

The name of the measurement file is always „HYDAC_SDMEU_Data_JJJJMM.csv“ and is found on the memory card in the following directory:

Every month, a new file is created.

The CSV file has the following structure:

Header Line Description

1 Product name 2 Software Version 3 Sensors 4 Measurement channels 5 Units

Records Column Description

A Date B Time C CS 1000 sensor connected

0 = False / 1=True D ISO > 4µm E ISO > 6µm F ISO > 14µm G ISO > 21µm H CS 1000 Status

0 = Undefined 1 = OK 2 = Error 3 = Flow 2 low 4 = ISO <9<8<7 5 = No value

I AS 1000 sensor connected 0 = False / 1=True

J Degree of saturation in % K Temperature in °C

Page 34: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 34BeWa SDMEU 3356723 en.doc 2007-07-20

Records Column Description

L HLB sensor connected 0 = False / 1=True

M Relative change of viscosity in % N Relative change in dielectric constant value in % O Degree of saturation in % P Temperature in °C Q HLB Status:

0 = Undefined 1 = Reference 2 = Operating 3 = OutOfRange 4 = Error

Example of a file view in MS Excel:

Page 35: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 35BeWa SDMEU 3356723 en.doc 2007-07-20

14 OPC Variables / OPC Server The OPC server is a software product from the Moeller company. For details on its installation and configuration, see the the included instructions from the Moeller company.

In addition to the OPC server, the IP address of the SDMEU must be customized for the client. For this purpose, there is a file on the memory card called „STARTUP.ini.“ With this file and with the help of an editor, you can change the IP address as well as the subnet mask. (Default setting: IP address 192.168.119.60, Subnet mask: 255.255.255.0).

The INI file is located in the same file as the CSV files.

Structure of INI files:

After changing the address, you must:

- save the entries,

- Reinsert the card in the control unit and

- Reboot the system

See the Moeller company manual for how to test if the address has been correctly set, as well as for connecting the network cable.

Page 36: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 36BeWa SDMEU 3356723 en.doc 2007-07-20

The following variables have been defined or enabled for communication using the OPC.

Variable Data type Description g_CS_Connected BOOL CS connected Yes/No

g_AS_Connected BOOL AS connected Yes/No

g_HLB_Connected BOOL HLB connected Yes/No

PLC_PRG.CS_iso4Value WORD ISO >4µ (CS1000)

PLC_PRG.CS_iso6Value WORD ISO >6µ (CS1000)

PLC_PRG.CS_iso14Value WORD ISO >14µ (CS1000)

PLC_PRG.CS_iso21Value WORD ISO >21µ (CS1000)

PLC_PRG.CS_stateValue WORD CS status as a number (see CSV file)

PLC_PRG.AS_SatValue INT Saturation percentage [%] (AS1000)

PLC_PRG.AS_TempValue INT Temperature [°C] (AS1000)

PLC_PRG.HLB_ViscoValue INT relative change in viscosity [%] (HLB)

PLC_PRG.HLB_DKValue INT relative change dielectric constant value [%] (HLB)

PLC_PRG.HLB_SatValue INT Water saturation degree [%] (HLB)

PLC_PRG.HLB_TempValue INT Temperature [°C] (HLB)

PLC_PRG.HLB_stateValue INT HLB status as a number (see CSV file)

These variables always give the current measured value/status and are not positioned according to the storage interval.

The corresponding symbol file is located on the memory card in the folder „…\Symbolfolie\ …“

15 Disposal / Recycling The packing material is to be disposed of as specified by law or national regulations. It can be reused.

When decommissioning and/or disposing of the SDMEU, adherence is to be maintained to local guidelines and regulations pertaining to occupational safety and environmental protection. This applies in particular to the oil in the unit, components covered with oil and electronic components.

After disassembling the unit and separating the various materials, they can be reused or disposed of properly in accordance with local regulations.

Page 37: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 37BeWa SDMEU 3356723 en.doc 2007-07-20

16 Sensor settings The connected sensors must be set up according to the following table for their correct operation with the SDMEU.

Sensor Program settings CS 1000 ANA.OUT = HDA.ISO

Measurement time = 60 sec.

AS 1000 None

HYDACLab none

17 Technical details

General data Mounting position Arbitrary

Self-diagnosis Continuously with error indication on display

Display LCD, 4-lined, 17 segmented

Drop (IEC/EN 60068-2-31) Fall height 50 mm

Ambient temperature range -25° - +55° C

Storage temperature range -40° - +70° C

relative humidity maximal 95%, non-condensing

Electrical safety class III (low voltage protection)

IP class IP66

Weight 1.3 kg

Electrical data

Voltage supply 24 V DC (-15%/+20%)

Residual ripple ≤ 5 %

Power consumption 3.5 Watt

Accuracy of the real-time clock ± 5 s/day / ± 0.5 h/year

Clock back-up 170 h

Vibrations (IEC/EN 60028-2-6)

- constant amplitude 0. 15 mm - constant acceleration 2g

5..9 Hz

8..150 Hz

Page 38: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

SensorDisplayMemoryEthernet Unit - SDMEU

HYDAC Filtertechnik GmbH en Page 38BeWa SDMEU 3356723 en.doc 2007-07-20

CPU

Microprocessor Infineon XC161

Memory specifications

Program code 256 kByte

Program data 14 segments of 16 KB each

Marker/Input/Output/Retain data 16/4/4/8 kByte

Cycle time for 1 k instructions < 0.3

18 Customer Service HYDAC Service GmbH

Product Support, Werk 7

Rehgrabenstrasse 3

D-66125 Saarbruecken / Dudweiler - Germany

Telephone: ++49 (0) 6897 / 509 – 01

Page 39: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

Note

Page 40: BeWa SDMEU 3356723 en - HYDAC...BeWa SDMEU 3356723 en.doc 2007-07-20 1.5 Informal Safety Precautions • Make sure to always keep the operating instructions in the vicinity of the

HYDAC Filtertechnik GmbH Bereich Servicetechnik / Service Technology Division Industriegebiet Postfach 1251 66280 Sulzbach/Saar 66273 Sulzbach/Saar Germany Germany Tel: +49 (0) 6897 509 01 Fax: +49 (0) 6897 509 846 (Technik / Technical Department) Fax: +49 (0) 6897 509 577 (Verkauf / Sales Department) Internet: www.hydac.com email: [email protected]