Axial Ventilators TJHU 60Hz_F400.F300_V31.01.2013

Embed Size (px)

Citation preview

  • 8/18/2019 Axial Ventilators TJHU 60Hz_F400.F300_V31.01.2013

    1/3

     

    Technical specifications for information only. Soler & Palau Sistemas de Ventilación S.L.U, reserves the right to change data without prior notice 

     Axial Jet Fans 

     ApplicationJet fans to induce air movement in enclosed car parking, tunnels and large spaces.TJHU: for ventilation and one off emergency smoke operation at F400, F300.

    TJFU: for ventilation only.0370-CPD- 

    DescriptionDiameters: 315, 355, 400 mm.Uni-direction impeller for airflow in forward direction, Form B.

    Impeller with 7 blades in cast aluminum alloy in accordance with EN 1706,

    and balanced in accordance with ISO 14694: G 6.3.

    Fan duct and 2 mounting feet are steel in accordance with EN 10130-99, and0370-CPD-1422 hot dip galvanized in accordance with EN 1461: 1999.

    Fan external electrical terminal box.

    Two circular sound attenuators in galvanised sheet steel, with flared inlet and

    acoustic media.Supplied with inlet and outlet steel guard.

    Complete fan assembly independently tested and approved in accordance

    with EN12101-3 at F400120 min, F300-120 min.

    MotorsIEC 80, 90 frame. 3phase/380V/60Hz. IP55.Class H at F400, F300.

    Two speed 2/4 pole Dalhander winding.Ambient temperature range -20ºC to +40ºC

    On requestVersion with single speed 2 pole motor.

    External terminal box Two protection guards on fan  Version with inlet guard and steel discharge deflector for uni-direction airflow.

    for ease of connection inlet and outlet Version with factory fitted IP65 isolator in place of fan electrical terminal box.

    Isolator also available as an accessory for use with standard terminal box fan.

    External painting to RAL colour.

     A P P L I C A T I O N S Optional deflector on outlet Optional electrical Isolator

    for uni-direction fitted to fan for security,or as accessory.

    Fan reference

    1. Fan type2. Motor speed (poles)3. Nominal diameter4. C= terminal box (standard). I=isolator (optional)5. Motor power in kW6. Emergency operation designation7. Nominal electrical suppy (Volts)8. Frequency (Hz)

    TJHU / 2 / 4 - 315 C / I 1.1 /0.25kW F300 380V 60Hz

    1 2 3 4 5 6 7 8

    TJHU

  • 8/18/2019 Axial Ventilators TJHU 60Hz_F400.F300_V31.01.2013

    2/3

     

    Technical specifications for information only. Soler & Palau Sistemas de Ventilación S.L.U, reserves the right to change data without prior notice 

     Axial Jet Fans 

    Technical characteristicsModel  Speed  Speed  Thrust   Ai rf low   Air velo ci ty   Motor*  FLC* Sound Weight 

    level**

     

    (poles) 

    (rpm)  (N)  (m3/h)  (m/s)  (kW)  (A)Form B***

      (LpA) (Kg) 

    UNI-DIRECTION - 1 speed 2 POLE

    TJHU/2-315-C  2 3265 33 5300 19 1.1 2.4 67 56

    TJHU/2-355-C  2 3400 57 7800 22 1.5 3.4 70 75

    TJHU/2-400-C  2 3450 89 11000 24 3 6.6 75 88

    UNI-DIRECTION - 2 speed 2/4 POLE

    TJHU/2/4-315-C  2/4  3290/1620 33/8 5300 19/9 1.1/0.25 2.6/0.8 67/50 56

    TJHU/2/4-355-C  2/4  3370/1670 57/14 7800 22/11 1.5/0.37 3.5/1.2 70/53 75

    TJHU/2/4-400-C  2/4  3460/1715 89/22 11000 24/12 3.1/0.8 7.1/2.5 75/58 88*May depend on motor used. **Sound pressure at 3m, hemispherica l propagation, in free field conditions, for comparison. *** Form B: Impeller over Motor (uni-directi on) 

    Dimensions (mm)

    C/C: Dimension with terminal boxC/I: Dimension with isolator

    Model   A  B  C/C  C/I ØD  E  H  L  L1

    315 310 405 236 279 385 485 397 1754 1797

    355 310 445 259 302 425 525 437 1754 1797

    400 310 506 283 326 486 586 498 1754 1797

    TJHU

  • 8/18/2019 Axial Ventilators TJHU 60Hz_F400.F300_V31.01.2013

    3/3

     

    Technical specifications for information only. Soler & Palau Sistemas de Ventilación S.L.U, reserves the right to change data without prior notice 

     Axial Jet Fans 

     Acoustic characteristics

    Sound power levels LwA ref 1pW. Tested in accordance with ISO 13347:2004

    2 pole 4 pole

    Form B: air direction Impeller over Motor  

    Wiring diagrams

    1 SPEED MOTOR 2 SPEED MOTOR (DALHANDER WINDING) 

    Form B  63 125 250 500 1k 2k 4k 8k  LwA

    315 66 66 68 79 78 79 71 66 84

    355 61 69 72 82 82 81 74 68 87

    400 72 74 73 82 86 87 80 75 91

    Form B  63 125 250 500 1k 2k 4k 8k  LwA

    315 45 54 58 61 61 54 50 43 66

    355 48 58 62 65 67 58 54 47 71

    400 51 62 65 70 67 64 60 52 74

    TJHU