Transfer switches ATyS d H Remotely operated Transfer Switching Equipment from 4000 to 6300 A > Data centre > Telecommunications > Industries The solution for > Ready for installation in the enclosure of your choice > High-performance switching > Safe on-load transfer: I-0-II Strong points > Please contact your SOCOMEC office Enclosed solution > The ATyS d H is an RTSE which is compatible with most building management systems. It may also be supplied as an ATSE by including an ATyS C20/C30/ C40 controller with a door mounted external display. External automatic controller > IEC 60947-6-1 > GB 14048-11 Conformity to standards Function The ATyS d H is a three-phase transfer switch, 3 and 4 poles, designed for low voltage high power applications that require high-performance and fast reliable switching. The open transition transfer is performed on-load in line with IEC 60947-6-1 and GB 14048-11 standards (Class PC) with minimal power supply interruption to the load during transfer. The ATyS d H is remote transfer switching equipment (RTSE) with an integrated dual power supply (DPS) that accepts remote orders through volt-free contacts. Advantages Ready for installation in the enclosure of your choice The ATyS d H has been designed to facilitate installation as it is available as a fixed or completely withdrawable type of transfer switch. It is composed of two switches that are mounted one above the other with easily accessible power connections located at the rear. Furthermore the ATyS d H does not need any external bridging bars as the load side is connected within the product. This enables to save time during installation. High-performance switching The ATyS d H offers high withstand short circuit current ratings of 143 kA I cm (making) and 65 kA for 0.1sec I cw (withstand). Further to its high short circuit withstand, the ATyS d H performance in terms of load switching capacity is AC-33iB (6 x I n cos Ø 0.5) without derating. Safe on-load transfer: I-0-II The ATyS d H includes two mechanically interlocked switches to ensure fast switching whilst providing a neutral (Off - 0) position. This ensures that the main and alternative power supplies do not overlap. Approvals and certifications atys_865_a 466 General Catalogue 2017-2018

ATyS d H - Socomec · atys_865_a ATyS d H Remotely operated Transfer Switching Equipment ... ATyS d H IEC ATyS d H CCC Control relay Reference Reference Reference 4000 A Fixed

  • Upload
    hathien

  • View
    238

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ATyS d H - Socomec · atys_865_a ATyS d H Remotely operated Transfer Switching Equipment ... ATyS d H IEC ATyS d H CCC Control relay Reference Reference Reference 4000 A Fixed

Tran

sfer

sw

itch

esATyS d HRemotely operated Transfer Switching Equipmentfrom 4000 to 6300 A

> Data centre > Telecommunications > Industries

The solution for

> Ready for installation in the enclosure of your choice

> High-performance switching > Safe on-load transfer: I-0-II

Strong points

> Please contact your SOCOMEC office

Enclosed solution

> The ATyS d H is an RTSE which is compatible with most building management systems. It may also be supplied as an ATSE by including an ATyS C20/C30/C40 controller with a door mounted external display.

External automatic controller

> IEC 60947-6-1 > GB 14048-11

Conformity to standardsFunction

The ATyS d H is a three-phase transfer switch, 3 and 4 poles, designed for low voltage high power applications that require high-performance and fast reliable switching. The open transition transfer is performed on-load in line with IEC 60947-6-1 and GB 14048-11 standards (Class PC) with minimal power supply interruption to the load during transfer. The ATyS d H is remote transfer switching equipment (RTSE) with an integrated dual power supply (DPS) that accepts remote orders through volt-free contacts.

Advantages

Ready for installation in the enclosure of your choiceThe ATyS d H has been designed to facilitate installation as it is available as a fixed or completely withdrawable type of transfer switch. It is composed of two switches that are mounted one above the other with easily accessible power connections located at the rear. Furthermore the ATyS d H does not need any external bridging bars as the load side is connected within the product. This enables to save time during installation.

High-performance switching The ATyS d H offers high withstand short circuit current ratings of 143 kA Icm (making) and 65 kA for 0.1sec Icw (withstand). Further to its high short circuit withstand, the ATyS d H performance in terms of load switching capacity is AC-33iB (6 x In cos Ø 0.5) without derating.

Safe on-load transfer: I-0-IIThe ATyS d H includes two mechanically interlocked switches to ensure fast switching whilst providing a neutral (Off - 0) position. This ensures that the main and alternative power supplies do not overlap.

Approvals and certifications

atys

_865

_a

ATyS d HRemotely operated Transfer Switching Equipment

from 4000 to 6300 A

References ATyS d H

Rating (A) Type Number of poles

ATyS d H IEC ATyS d H CCC Control relay

Reference Reference Reference

4000 A

Fixed3 P 9533 3400 9533 3400 CN

ATyS C201599 3020

ATyS C301599 3030

ATyS C401599 3040

4 P 9533 4400 9533 4400 CN

Withdrawable3 P 9533 3401 9533 3401 CN4 P 9533 4401 9533 4401 CN

5000 A

Fixed3 P 9533 3500 9533 3500 CN

4 P 9533 4500 9533 4500 CN

Withdrawable3 P 9533 3501 9533 3501 CN4 P 9533 4501 9533 4501 CN

6300 A

Fixed3 P 9533 3630 9533 3630 CN

4 P 9533 4630 9533 4630 CN

Withdrawable3 P 9533 3631 9533 3631 CN

4 P 9533 4631 9533 4631 CN

(1) Instantaneous value. For a complete operation, power should be available during 0.5 s.

Characteristics according to IEC 60947-6-14000 to 6300 A

Thermal current Ith at 40°C 4000 A 5000 A 6300 ARated operating voltage Ue (V) 660Rated insulation voltage Ui (V) 660Rated impulse withstand voltage Uimp (kV) 12

Rated short-circuit withstand at 660 VACRated short-time withstand current 0.1s Icw (kA rms) 65Rated peak withstand current (kA peak) 143Rated operational current Ie (A), at 660 VAC - AC32B 4000 5000 6300Rated operational current Ie (A), at 660 VAC - AC33iB (6xIn cos Ø 0.5) 4000 5000 6300

ConnectionRear connection with busbar • • •

Switching timeI to 0 (ms) ≤ 1500 to I and 0 to II (ms) ≤ 90II to 0 (ms) ≤ 200I-0-II / II-0-I (s) 1.2Operating frequency 10 operations per hour

Power supplyVAC power supply (powered directly on terminals S1 and S2) 230Main coil operating current (peak during transfers) 65 A(1)

Mechanical characteristicsDurability (number of operating cycles) 3000Weight (kg) - Fixed 3/4P model 200 / 250 200 / 250 200 / 250Weight (kg) - Plug-in 3/4P model 300 / 400 300 / 400 300 / 400

466 General Catalogue 2017-2018

Page 2: ATyS d H - Socomec · atys_865_a ATyS d H Remotely operated Transfer Switching Equipment ... ATyS d H IEC ATyS d H CCC Control relay Reference Reference Reference 4000 A Fixed

Tran

sfer

sw

itch

es

ATyS d HRemotely operated Transfer Switching Equipmentfrom 4000 to 6300 A

> Data centre > Telecommunications > Industries

The solution for

> Ready for installation in the enclosure of your choice

> High-performance switching > Safe on-load transfer: I-0-II

Strong points

> Please contact your SOCOMEC office

Enclosed solution

> The ATyS d H is an RTSE which is compatible with most building management systems. It may also be supplied as an ATSE by including an ATyS C20/C30/C40 controller with a door mounted external display.

External automatic controller

> IEC 60947-6-1 > GB 14048-11

Conformity to standardsFunction

The ATyS d H is a three-phase transfer switch, 3 and 4 poles, designed for low voltage high power applications that require high-performance and fast reliable switching. The open transition transfer is performed on-load in line with IEC 60947-6-1 and GB 14048-11 standards (Class PC) with minimal power supply interruption to the load during transfer. The ATyS d H is remote transfer switching equipment (RTSE) with an integrated dual power supply (DPS) that accepts remote orders through volt-free contacts.

Advantages

Ready for installation in the enclosure of your choiceThe ATyS d H has been designed to facilitate installation as it is available as a fixed or completely withdrawable type of transfer switch. It is composed of two switches that are mounted one above the other with easily accessible power connections located at the rear. Furthermore the ATyS d H does not need any external bridging bars as the load side is connected within the product. This enables to save time during installation.

High-performance switching The ATyS d H offers high withstand short circuit current ratings of 143 kA Icm (making) and 65 kA for 0.1sec Icw (withstand). Further to its high short circuit withstand, the ATyS d H performance in terms of load switching capacity is AC-33iB (6 x In cos Ø 0.5) without derating.

Safe on-load transfer: I-0-IIThe ATyS d H includes two mechanically interlocked switches to ensure fast switching whilst providing a neutral (Off - 0) position. This ensures that the main and alternative power supplies do not overlap.

Approvals and certifications

atys

_865

_a

ATyS d HRemotely operated Transfer Switching Equipment

from 4000 to 6300 A

References ATyS d H

Rating (A) Type Number of poles

ATyS d H IEC ATyS d H CCC Control relay

Reference Reference Reference

4000 A

Fixed3 P 9533 3400 9533 3400 CN

ATyS C201599 3020

ATyS C301599 3030

ATyS C401599 3040

4 P 9533 4400 9533 4400 CN

Withdrawable3 P 9533 3401 9533 3401 CN4 P 9533 4401 9533 4401 CN

5000 A

Fixed3 P 9533 3500 9533 3500 CN

4 P 9533 4500 9533 4500 CN

Withdrawable3 P 9533 3501 9533 3501 CN4 P 9533 4501 9533 4501 CN

6300 A

Fixed3 P 9533 3630 9533 3630 CN

4 P 9533 4630 9533 4630 CN

Withdrawable3 P 9533 3631 9533 3631 CN

4 P 9533 4631 9533 4631 CN

(1) Instantaneous value. For a complete operation, power should be available during 0.5 s.

Characteristics according to IEC 60947-6-14000 to 6300 A

Thermal current Ith at 40°C 4000 A 5000 A 6300 ARated operating voltage Ue (V) 660Rated insulation voltage Ui (V) 660Rated impulse withstand voltage Uimp (kV) 12

Rated short-circuit withstand at 660 VACRated short-time withstand current 0.1s Icw (kA rms) 65Rated peak withstand current (kA peak) 143Rated operational current Ie (A), at 660 VAC - AC32B 4000 5000 6300Rated operational current Ie (A), at 660 VAC - AC33iB (6xIn cos Ø 0.5) 4000 5000 6300

ConnectionRear connection with busbar • • •

Switching timeI to 0 (ms) ≤ 1500 to I and 0 to II (ms) ≤ 90II to 0 (ms) ≤ 200I-0-II / II-0-I (s) 1.2Operating frequency 10 operations per hour

Power supplyVAC power supply (powered directly on terminals S1 and S2) 230Main coil operating current (peak during transfers) 65 A(1)

Mechanical characteristicsDurability (number of operating cycles) 3000Weight (kg) - Fixed 3/4P model 200 / 250 200 / 250 200 / 250Weight (kg) - Plug-in 3/4P model 300 / 400 300 / 400 300 / 400

467General Catalogue 2017-2018

Page 3: ATyS d H - Socomec · atys_865_a ATyS d H Remotely operated Transfer Switching Equipment ... ATyS d H IEC ATyS d H CCC Control relay Reference Reference Reference 4000 A Fixed

ATyS d HRemotely operated Transfer Switching Equipmentfrom 4000 to 6300 A

DimensionsDimensions for fixed models

atys

-dh_

006_

b_1_

x_ca

t

1. Fixing hole base: Ø13 mm

Ø13

16

530

833 (3P) / 1064 (4P)

865 (3P) / 1096 (4P)

16

1

1

1

1

1

1

1

A Power

B Power

LOAD

491 52 38

163 280

603

79 3822

190

700

105

105

3030

30

217

15

1 11

S NR S T TR R SR S TTN

195

52

21

80

25 25

230 230 161282

195 195 195 195 195

256 256 161

52

ATyS d HRemotely operated Transfer Switching Equipment

from 4000 to 6300 A

Dimensions for drawout models

atys

-dh_

007_

b_1_

x_ca

t

1. Fixing hole base: Ø13 mm

Ø13

21

80

25 25

56

602

704 (3P) / 934 (4P)82 82

868 (3P) / 1098 (4P)

616 56 38

A Power

B Power

LOAD

198

105

105

3070

030

30

275 165

732

S TR R S T

195247195

96256256

S NR S T TR N

195195195195

96230282230

38

225

15

22 211

1 111

468 General Catalogue 2017-2018

Page 4: ATyS d H - Socomec · atys_865_a ATyS d H Remotely operated Transfer Switching Equipment ... ATyS d H IEC ATyS d H CCC Control relay Reference Reference Reference 4000 A Fixed

ATyS d HRemotely operated Transfer Switching Equipmentfrom 4000 to 6300 A

DimensionsDimensions for fixed models

atys

-dh_

006_

b_1_

x_ca

t

1. Fixing hole base: Ø13 mm

Ø13

16

530

833 (3P) / 1064 (4P)

865 (3P) / 1096 (4P)

16

1

1

1

1

1

1

1

A Power

B Power

LOAD

491 52 38

163 280

603

79 3822

190

700

105

105

3030

30

217

15

1 11

S NR S T TR R SR S TTN

195

52

21

80

25 25

230 230 161282

195 195 195 195 195

256 256 161

52

ATyS d HRemotely operated Transfer Switching Equipment

from 4000 to 6300 A

Dimensions for drawout models

atys

-dh_

007_

b_1_

x_ca

t

1. Fixing hole base: Ø13 mm

Ø1321

80

25 25

56

602

704 (3P) / 934 (4P)82 82

868 (3P) / 1098 (4P)

616 56 38

A Power

B Power

LOAD

198

105

105

3070

030

30

275 165

732

S TR R S T

195247195

96256256

S NR S T TR N

195195195195

96230282230

38

225

15

22 211

1 111

469General Catalogue 2017-2018