APPENDIX A – Architectural Plans
APPENDIX A – Architectural Plans
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
N2
PROPOSED 8x MOTEL ROOMS
COVER SHEET
DB
000
ID8738
HOUSING 101
A 16.11.16PRELIMINARY ISSUE DB
PROPOSED 8xMOTEL ROOMS
FOR HOUSING 101
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
N2
PROPOSED 8x MOTEL ROOMS
GENERAL NOTES
DB
001
ID8738
HOUSING 101
000 COVER SHEET
001 GENERAL NOTES
101 SITE PLAN
201 GROUND FLOOR PLANS
301 ELEVATIONS
303 SECTIONS
401 SLAB
501 ELECTRICAL PLAN
CONSTRUCTION NOTESALL WORK TO COMPLY WITH THE NATIONAL CONSTRUCTION CODE OF AUSTRALIAREQUIREMENTS (NCC) AND AUSTRALIAN STANDARDS AND THEIR MOST CURRENTAMENDMENTS. ALL LOCAL COUNCIL REQUIREMENT ARE TO BE MET IN RELATION TO THECLASS AND TYPE OF CONSTRUCTION
BEFORE COMMENCING CONSTRUCTION ALL DIMENSIONS, EXISTING LEVELS, FINISHEDLEVELS AND ALL SITE SERVICES ARE TO BE VERIFIED BY THE BUILDER. NOTIFY THEARCHITECT OF ANY VARIATION BETWEEN THE DOCUMENTATION AND SITE CONDITIONS.
WRITTEN DIMENSIONS ARE TO TAKE PRECEDENCE OVER SCALING FROM THE DRAWINGS.NOTIFY THE ARCHITECT OF ANY VARIATIONS OR DISCREPANCIES IN THE DIMENSIONING OFTHE PLANS.
REFER TO ENGINEERS DETAILS FOR SOIL CLASSIFCATION AND ALL STRUCTURAL MEMBERSIZES, BRACING DETAIL AND POSITIONING OF CONSTRUCTION JOINTS WHERE REQUIRED.
BUILDER TO TAKE ALL STEPS NEEDED TO ENSURE THE STABILITY OF EXISTING AND NEWSTRUCTURES THROUGH-OUT CONSTRUCTION.
MANHOLE TO BE POSITIONED TO SUIT TRUSS LAYOUT. POSITION TRUSSES SO AS TOPROVIDE A CLEAR 600mm x 600mm OPENING. MANHOLE POSITION AS INDICATED ON PLAN
TERMITE PROTECTION TO COMPLY WITH AS 3660 AND AS 3660.1 AND A DURABLE NOTICESHALL BE PLACED IN THE METER BOX INDERCATING TYPE OF BARRIER AND REQUIREDPERIODICAL INSPECTIONS
ALL BATHROOMS, LAUNDRIES, ENSUITES AND WC'S NOT NATURALLY VENTILATED ARE TOBE MECHANICALLY VENTILATED TO COMPLY WITH 1668.2 AND AS/NZS 3666.1
WINDOW FRAME AND GLAZING TO BE INSTALLED IN ACCORDANCE WITH AS1288 AND TOMANUFACTURES REQUIREMENTS. AND SAFETY GLAZING TO BE USED IN THE FOLLOWINGCASES:• ALL ROOMS- WITHIN 500mm VERTICAL FROM FLOOR• BATHROOMS- WITHIN 1500mm VERTICAL FROM FLOOR• WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL• FULLY GLAZED DOORS• SHOWER SCREENS
WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY WITH MANUFACTURERSPECIFCATIONS, FLASHING REQUIRED ALL ROUND
POOL FENCING TO COMPLY WITH AS 1926.1 & 2 AND CURRENT REGULATIONS OF LOCALCOUNCIL
SMOKE ALARMS TO COMPLY WITH AS 3786
STAIRS, HANDRAILS AND BALUSTRADES TO COMPLY WITH CURRENT N.C.C. AND AS1170INCLUDING AS1288
BALUSTRADES TO HAVE A MINIMUM HEIGHT OF 1000mm ABOVE FINISHED SURFACE LEVEL.
STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE AS DETERMINED BY THERELEVANT AUTHORITY. AND COMPLY WITH CURRENT N.C.C. AND AS/NZS 3500
FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT IS RECOMMENDEDTHAT WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITY OF BOUNDARIES, ACHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH CURRENT N.C.C. AND AS 3740. SPLASH BACKS SHALL BEIMPERVIOUS FOR 150MM ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75MM OF THEWALL.
PROVIDE WALL TIES AT 600MM SPACINGS BOTH VERTICAL AND HORIZONTAL AND WITHIN300MM OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500MM SQ FOR EXTERNAL WALLS AND 1500MM SQ FORINTERNAL WALLS BELOW BEARER.
THERMAL INSULATION; R3.0 BATTS TO CEILING AND R1.0 BATTS AND REFLECTIVE FOIL TOEXTERNAL WALLS OR AS PER ENERGY RATING.
PROVIDE LIFT OFF HINGES TO W.C OR OPEN OUT DOOR OR MIN 1200MM CLEARANCE FROMDOOR TO PAN.
EXHAUST FANS FROM SANITARY COMPARTMENTS TO BE DUCTED TO THE OUTSIDE ARE AIROR TO A VENTED ROOF SPACE AND AS PER AS 1668.2
ALL CONSTRUCTION MATERIALS SUPPLIED MUST TAKE INTO ACCOUNT PROXIMITY TOCOASTAL OR INDUSTRIAL ENVIRONMENTS, IN ACCORDANCE WITH MANUFACTURERSSPECIFICATIONS
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS,STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS.
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THE AUTHOR.
PLANS MARKED CONSTRUCTION DRAWINGS AND CROSS REFERENCES ARE FOR BUILDINGPURPOSES ONLY AND DO NOT FORM PART OF THE CONTRACT DOCUMENTS
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
EXISTING MOTEL
EXISTING HOTEL
EXISTINGBOTTLESHOP
EXISTING WALKWAY
PROPOSED 8xMOTEL ROOMS
BRISBANE VALLEY HIGHWAY
85.2
7m
26
°30'
54.31m126°0'
84.1
0m
216°0
'
40.234m306°0'
EM
T. A
3.0m306°0'
3.0m126°0'
OMP
4082
EX. DRIVEWAY
6500
EXISTING PARKING FOR THE8 EXISTING MOTEL ROOMS
8 PROPOSED PARKINGSPOTS FOR PROPOSEDMOTEL ROOMS
FUTURE CARPARKING
2500
5400
5400
2500 2500
5400
EXISTINGDRIVE
THROUGH
REAL PROPERTY DESCRIPTIONRP -LOT -PARISH -COUNTY -AREA -
SP18065710
NORTHCHURCHILL
3976m²
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
As indicated
N2
PROPOSED 8x MOTEL ROOMS
SITE PLAN
DB
101
ID8738
HOUSING 101
GENERAL NOTES:
SITE LAYOUT SHALL BE READ IN CONJUNCTION WITH ENGINEER'SSOIL REPORT AND DETAILS.
ALL DIMENSIONS AND LEVELS SHALL BE CHECKED ON SITE PRIOR TOCOMMENCEMENT OF THE WORKS. DIMENSIONS SHOWN ARE TOFACE OF EXTERNAL CLADDING AND/ OR FRAME ONLY. DO NOTSCALE. ANY DISCREPANCIES TO BE REPORTED IMMEDIATELY TOHEAD OFFICE.
SITE NOTES:
EARTHWORKS
CUT AND FILL BANKS AND BATTERS SHALL BE IN ACCORDANCE WITHN.C.C AND DEVELOPERS REQUIREMENTS.
CUT AND FILL INDICATED ON PLAN MAY VARY AT CONSTRUCTIONSTAGE
ANY VERIATION TO COMPLY WITH ALL COUNCIL POLICY'S ONEARTHWORKS/DRAINAGE FOR RESIDENTAIL SITES
SITE WORKS ON THIS PLAN ARE FOR CONSTRUCTION PURPOSESONLY. AS FOR FINAL LEVELS, LANDSCAPING AND DRAINAGE THAT ISTHE RESPONSIBLILTY OF THE OWNER/BUILDER
STORMWATER
STORM WATER LAYOUT (WHEN SHOWN) IS INDICATIVE ONLY ANDSHALL BE DIRECTED TO STREET OR TO SOAKAGE PITS TO COUNCILREQUIREMENTS.
CONTOURS AND LEVELS
PLATFORM IMMEDIATELY SURROUNDING THE RESIDENCE SHALLFALL AWAY FROM THE RESIDENCE AT A SLOPE OF 1 IN 20.
ALL SURFACE DRAINAGE SHALL DISCHARGE WITHIN THE SITEWITHOUT NUISANCE TO ADJOINING PROPERTIES.
CONTOURS AND LEVELS SHOWN ARE TAKEN FROM LEVELSSUPPLIED BY 'COUNTOUR SURVEYOR' AND NO RESPONSIBILITY ISTAKEN FOR ACCURANCY
RETAINING WALLS
POSITION OF RETAINING WALLS AND EMBANKMENTS MAY VARYACCORDING TO SITE WORKS AND BUILDER TO VERIFY AND ADJUSTAS REQUIRED AND MUST COMPLY TO COUNCIL REQUIREMENTS.
WHEN RELEVANT:SEWERAGE SHALL BE CONNECTED TO OWNER SUPPLIED D.S.T.P.WITHIN 10m OF HOUSE WITH SUITABLE FALL. OWNER TO PROVIDELOCATION ON SEPERATE APPLICATION.
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
1 : 500
SITE PLAN1
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
301
2
301
1
301 3
EXISTING BUILDING
CLCLCLCLCLCLCLCLCL
EQ EQ EQ EQ EQ EQ EQ EQ
2400
3300
14400 14400
100
2300
82
3136
82
82 2414 86 945 152 945 86 2414 152 2414 86 945 152 945 86 2414 82
WALKWAYCONCRETE TO
MATCH EXISTING
BED 5EXISTING
VINYL
ENS. 5EXISTING
VINYL
BED 7EXISTING
VINYL
ENS. 7EXISTING
VINYL
BED 8EXISTING
VINYL
ENS. 8EXISTING
VINYL
BED 6EXISTING
VINYL
ENS. 6EXISTING
VINYL
820
EX
.D
OO
R
EX
.D
OO
R
EX
.D
OO
R
EX
.D
OO
R
820 820 820
EX. WIN. EX. WIN. EX. WIN. EX. WIN.
1303
WALKWAYCONCRETE TO
MATCH EXISTING
BED 1EXISTING
VINYL
ENS. 1EXISTING
VINYL
BED 3EXISTING
VINYL
ENS. 3EXISTING
VINYL
BED 4EXISTING
VINYL
ENS. 4EXISTING
VINYL
BED 2EXISTING
VINYL
ENS. 2EXISTING
VINYL
820
EX
.D
OO
R
EX
.D
OO
R
EX
.D
OO
R
EX
.D
OO
R
820 820 820
EX. WIN. EX. WIN. EX. WIN. EX. WIN.
82 2414 86 945 152 945 86 2414 152 2414 86 945 152 945 86 2414 82
EX. WIN.EX. WIN. EX. WIN.EX. WIN. EX. WIN.EX. WIN.EX. WIN.EX. WIN.
FLOOR COVERINGS LEGEND
SELECTED TIMBER BY CLIENT
PLAIN CONCRETE
NOTE: FLOOR COVERINGSSHOWN ARE INDICATIVE ONLY.LAYING PATTERN, DIRECTIONAND SIZE MAY VARY
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
1 : 100
N2
PROPOSED 8x MOTEL ROOMS
GROUND FLOOR PLANS
DB
201
ID8738
HOUSING 101
S
GENERAL NOTES:
ALL DIMENSIONS AND LEVELS SHALL BE CHECK ON SITE PRIOR
TO COMMENCEMENT OF THE WORKS. DIMENSIONS SHOWN ARE
TO FACE OF EXTERNAL CLADDING AND/ OR FRAME ONLY. DO
NOT SCALE. ANY DISCREPENCIES TO BE REPORTED
IMMEDIATELY TO HEAD OFFICE.
WINDOW AND DOOR SIZES ARE NOMINAL ONLY, REFER TO
MANUFACTURER'S SPECIFICATIONS AND SCHEDULES.
- DENOTES HARDWIRED SMOKE DETECTORS TO AS3786 -
1993 WITH 9V BATTERY BACKUP.
- DENOTES LOAD BEARING WALL.
- DENOTES POINT LOAD.
- DENOTES ARTICULATION JOINT
LBW
AJ
1 : 100
PROPOSED GROUND FLOOR1
DOOR SCHEDULE
Count Size Type8 720 Existing Swing Door
8 820 Swing Door With0.75x0.6 Glass Panel
WINDOW SCHEDULE
Count Size Type8 350x750 Existing Sliding
Window
8 1200x908
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
GROUND FLOOR
U/S CEILING
NGL
2445
PAINTED LIGHTWIEGHT BRICKCLADDING FIXED TO MANUF.SPEC'S
ALUMINIUM FRAMED DOORSINSTALLED TO MANUFACTURER'SSPECIFICATIONS
CUSTOM ORB ROOF SHEETINGTO MATCH EXISTING FIXED TOMANUF. SPEC'S
BULLNOSE TO MATCH EXISTINGFIXED TO MANUF. SPEC'S
FEATURE TIMBER TO MATCHEXISTING
GROUND FLOOR
U/S CEILING
2445
NGL
PAINTED WEATHERTEX CLADDINGFIXED TO MANUF. SPEC'S
GROUND FLOOR
U/S CEILING
2445
PAINTED WEATHERTEX CLADDINGFIXED TO MANUF. SPEC'S
CUSTOM ORB ROOF SHEETINGTO MATCH EXISTING FIXED TOMANUF. SPEC'S
BULLNOSE TO MATCH EXISTINGFIXED TO MANUF. SPEC'S
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
1 : 100
N2
PROPOSED 8x MOTEL ROOMS
ELEVATIONS
DB
301
ID8738
HOUSING 101
GENERAL NOTES:
ALL DIMENSIONS AND LEVELS SHALL BECHECKED ON SITE PRIOR TOCOMMENCEMENT OF THE WORKS.DIMENSIONS SHOWN ARE TO FACE OFEXTERNAL CLADDING AND/ OR FRAME ONLY.DO NOT SCALE. ANY DISCREPANCIES TO BEREPORTED IMMEDIATELY TO HEAD OFFICE.
CUT AND FILL BANKS AND BATTERS SHALL BEIN ACCORDANCE WITH BCA ANDDEVELOPERS REQUIREMENTS.
PLATFORM IMMEDIATELY SURROUNDING THERESIDENCE SHALL FALL AWAY FROM THERESIDENCE AT A SLOPE OF 1 IN 20.
1 : 100
FRONT ELEVATION1
1 : 100
BACK ELEVATION2
1 : 100
SIDE ELEVATION3 REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
GROUND FLOOR
U/S CEILING
WALKWAY BED 5
ROOF SYSTEM ASPER ENG. SPEC'S
SLAB ANDFOOTINGS TOENG. SPEC'S
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
1 : 50
N2
PROPOSED 8x MOTEL ROOMS
SECTIONS
DB
303
ID8738
HOUSING 101
GENERAL NOTES:
ALL DIMENSIONS AND LEVELS SHALL BECHECKED ON SITE PRIOR TOCOMMENCEMENT OF THE WORKS.DIMENSIONS SHOWN ARE TO FACE OFEXTERNAL CLADDING AND/ OR FRAME ONLY.DO NOT SCALE. ANY DISCREPANCIES TO BEREPORTED IMMEDIATELY TO HEAD OFFICE.
CUT AND FILL BANKS AND BATTERS SHALL BEIN ACCORDANCE WITH BCA ANDDEVELOPERS REQUIREMENTS.
PLATFORM IMMEDIATELY SURROUNDING THERESIDENCE SHALL FALL AWAY FROM THERESIDENCE AT A SLOPE OF 1 IN 20.
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
1 : 50
SECTION 11
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
WALKWAY25mm SETDOWN
EXISTINGWALKWAY SLABF
ALL
FA
LL
BLOCK WALL TO PETER TO NATURAL
LINE OF FLOOR ABOVE EXISTINGMOTEL SLAB
WALKWAY25mm SETDOWN
FA
LL
FA
LL
LINE OF FLOOR ABOVE
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
1 : 100
N2
PROPOSED 8x MOTEL ROOMS
SLAB
DB
401
ID8738
HOUSING 101
GENERAL NOTES:
ALL DIMENSIONS AND LEVELS SHALL BECHECKED ON SITE PRIOR TO COMMENCEMENTOF THE WORKS. DIMENSIONS SHOWN ARE TOFACE OF EXTERNAL CLADDING AND/ ORFRAME ONLY. DO NOT SCALE. ANYDISCREPANCIES TO BE REPORTEDIMMEDIATELY TO HEAD OFFICE.
CUT AND FILL BANKS AND BATTERS SHALLBE IN ACCORDANCE WITH BCA ANDDEVELOPERS REQUIREMENTS.
PLATFORM IMMEDIATELY SURROUNDING THERESIDENCE SHALL FALL AWAY FROM THERESIDENCE AT A SLOPE OF 1 IN 20.
SLAB NOTES:
REFER TO ENGINEERS PLANS FORSTRUCTURAL SLAB DESIGN.
DIMENSIONS PROVIDED FOR PLUMBINGFIXTURES ARE INDICATIVE ONLY AND MAYVARY ACCORDING TO THE TYPE OF FIXTURESUSED.
ALL DIMENSIONS TO BE CONFIRMED AGAINSTFLOOR PLAN AND CONFIRMED BYOWNER/BUILDER PRIOR TO BUILDING WORKS.
TERMITE PROTECTION AS PER AS3660.1-2000(PROTECTION OF BUILDINGS FROM SUB-TERRANEAN TERMITES- NEW BUILDINGS).
PERIMETER - KORDON OR EQUIVALENTPENETRATIONS - KORDON OR EQUIVALENT
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
1 : 100
PROPOSED SLAB PLAN1
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB
THIS BUILDING SHALL BE CONSTRUCTED INACCORDANCE WITH QLD BUILDING ACT 1975-91,THE CURRENT NCC, ALL RELEVANT AUSTRALIANSTANDARDS AND THE MANUFACTURERSSPECIFICATIONS FOR RELEVANT ELEMENTS.
SUBSTITUTION OF ANY STRUCTURAL MEMBERS,& OR VARIATIONS TO ANY PART OF THE DESIGN,WILL VOID ANY RESPONSIBILITIES OF THEBUILDING DESIGNER FOR THE STRUCTURALINTEGRITY & PERFORMANCE OF THE BUILDING
WIND SPEED
CLASSIFICATION
PROJECT
TITLE
DRAWN:
DATE:
SCALE:
SHEET
No:
SHEET SIZE:
JOB NO.CLIENT
SITE A3ISSUE: DESCRIPTION: DATE: BY:
FERNVALE HOTEL-MOTEL, 1490 BRISBANE VALLEY HIGHWAY,
FERNVALE, QLD, 4306
1 : 100
N2
PROPOSED 8x MOTEL ROOMS
ELECTRICAL PLAN
DB
501
ID8738
HOUSING 101
ELECTRICAL NOTES:
QDC MP 4.1- SUSTAINABLE BUILDINGS
ENERGY EFFICIENT LIGHTING:
FLUORESCENT LIGHTS OR COMPACTFLUORESCENT LIGHTS (CFLS) MUST BE THEONLY FIXED ARTIFICIAL LIGHT SOURCE USEDIN ROOMS THAT ACCOUNT FOR AT LEAST40% OF THE TOTAL FLOOR AREA
WATER CONSERVATION:
ALL SHOWER ROSES TO BE AAA RATED ORHAVE THREE STAR (WELS) RATING
TOILETS TO BE 6/3 LITRE DUAL FLUSHCISTERNS 3.7.2.
HOT WATER SUPPLY:
HOTWATER IS SUPPLIED BY:
1. A HEAT PUMP OR SOLAR HOT WATERSYSTEM THAT IS ELIGIBLE TO RECEIVE:
(a). IN A BUILDING WITH 3 OR MOREBEDROOMS, AT LEAST 22 RENEWABLEENERGY CERTIFICATES; OR
(b). OTHERWISE, AT LEAST 14 RENEWABLEENERGY CERTIFICATES; OR
(c). A GAS HOT WATER SYSTEM WITH A FIVESTAR ENERGY RATING
ALL SMOKE ALARMS TO COMPLY WITHCURRENT N.C.C. CODE & AS 3786
REFER TO ATTACHED PREVIOSALCERTIFIED ATCO STRUCTURES SERIEALNUMBER: 314100954 & 314102393
A 16.11.16PRELIMINARY ISSUE DB
1 : 100
PROPOSED ELECTRICAL PLAN1
LEFT BLANK FOR ELECTRICIAN
B 17.11.16PRELIMINARY ISSUE #2 DB
C 01.11.17FOR CONSTRUCTION/APPROVAL DB