24
1 Analytical study of multiple scattering SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna A detector independent analytical study of the contribution of multiple scattering to the momentum error in barrel detectors and comparison with an exact Kalman filter

and comparison with an exact Kalman filter

  • Upload
    nuri

  • View
    55

  • Download
    0

Embed Size (px)

DESCRIPTION

A detector independent analytical study of the contribution of multiple scattering to the momentum error in barrel detectors. and comparison with an exact Kalman filter. Introduction. Gluckstern’s formulae [1] Frequently used Often stressed far beyond their limits - PowerPoint PPT Presentation

Citation preview

Page 1: and comparison with an exact Kalman filter

1Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

A detector independent analytical study of the contribution of multiple scattering to the momentum error in

barrel detectors

and comparison with an exact Kalman filter

Page 2: and comparison with an exact Kalman filter

2Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Introduction

• Gluckstern’s formulae [1]

– Frequently used

– Often stressed far beyond their limits

– Assumptions: constant magnetic field, track in the symmetry plane (perpendicular to the magnetic field)

• Generalization of Gluckstern’s formulae [2]

– Different resolutions, material budgets

– Quite large incident angles, high curvatures

– Only in symmetry plane of barrel detector (see above)

Page 3: and comparison with an exact Kalman filter

3Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Introduction

homogeneous material,equidistant measurements

• Rossi: multiple scattering in homogeneous detectors (diagonal elements)

• Gluckstern: First attempt to deal with multiple scattering in discrete detectors, based on earlier publication by Bruno Rossi

Page 4: and comparison with an exact Kalman filter

4Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Introduction• Multiple scattering, general formulae

– General case applied at the Split Field Magnet (SFM) at the first high energy pp collider (CERN Intersecting Storage Rings ISR) [3]

– Only restriction: validity of local linear expansion

• Aim of this study:– Complement generalized Gluckstern formulae for realistic dip angle

λ range in the barrel region– Method independent of detector, mathematically exact– Detector optimization: needs 9 coefficients per detector setup instead

of simulation program– Prerequisites: detector rotational symmetric, invariant w.r.t.

translations parallel to magnetic field (no z dependent resolution in e.g. a TPC)

Page 5: and comparison with an exact Kalman filter

5Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Sample detector for simulation

• Example silicon detector– B = 4 [T], solenoid– 11 cylinder layers– 10 mm ≤ R ≤ 1010 mm equidistant– Thickness of each layer: X = 0.01 X0

– Point resolutions σ(RΦ) = σ(z) = 5μm– Reference surface in front of innermost detector layer

• Simulation with LiC Detector Toy 2.0 [4]

– Parameters: λ, φ, κ = 1/RH

Page 6: and comparison with an exact Kalman filter

6Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

The global formula• In plane z = 0: σ(Δpt/pt)=σ(Δp/p)• Global formula (extension to λ ≠ 0):

– Without MS:Follows behavior of detector errors (see below)

– With MS: σ(λ) and ρ(λ,κ) have to be studied more extensively

Page 7: and comparison with an exact Kalman filter

7Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

• Assumptions:– multiple scattering in λ and in φ independent

– > covariance matrix block diagonal

• General covariance matrix for discrete layers:

Multiple scattering covariance matrix

Page 8: and comparison with an exact Kalman filter

8Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Multiple scattering covariance matrix

• Rossi-Greisen:

• Extension to λ ≠ 0:

• Least squares method: • Rigorous procedure:

– VMS dominates at low pt, but is singular– Vdet from detector errors, asymptotic values– keep Vdet for inversion, after inversion limit Vdet → 0

Page 9: and comparison with an exact Kalman filter

9Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Multiple scattering in λ

• Covariance matrix:

– With

• Derivative matrix Dz for LSM:

– Dimension: NCoordinates x 2

Page 10: and comparison with an exact Kalman filter

10Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Multiple scattering in λ

• Derivatives from geometry:

LSM

λ

zi

z

ds

dz

sp

s

a1,2 and a2,2 not straight forwarddeterminable at λ = 0!

Page 11: and comparison with an exact Kalman filter

11Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

• Covariance matrix:

– Projection to plane B→ additional factor

• Derivative matrix DRΦ for LSM:

– Dimension: NCoordinates x 2

Multiple scattering in φ

Page 12: and comparison with an exact Kalman filter

12Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Multiple scattering in φ

• λ ≠ 0, low pt: Correlations between λ and φ (b)

• Calculated derivatives checked by simulationb1,1 and b1,2 not straight forward

determinable at λ = 0!

Page 13: and comparison with an exact Kalman filter

13Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Total multiple scatteringcovariance matrix

• Comparison of magnitude by simulation yields:– a1,1 >> b1,1 (var(λ) dominated by λ scattering)

b1,1 at 1 GeV/c comparable to the corresponding value due to detector errors, but several orders of magnitude smaller than a1,1

– a1,2 >> b1,2 (cov(λ,κ) dominated by λ scattering)

– b2,2 >> a2,2 (var(κ) dominated by φ scattering)

Page 14: and comparison with an exact Kalman filter

14Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Total multiple scattering matrix

var(λ) ~ cos(λ)cov(λ,κ) ~ sin(λ)

var(κ) ~ 1/cos(λ)

– blue: λ scattering

– green: φ scattering

– red: both

dominated byλ scattering

dominated byλ scattering

dominated byφ scattering

Page 15: and comparison with an exact Kalman filter

15Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

The covariance in the global formula

0º 1.181 ∙ 10-3 0 3.004 ∙ 10-3 3.004 ∙ 10-3 3.004 ∙ 10-3

15º 1.159 ∙ 10-3 - 0.095 3.072 ∙ 10-3 3.060 ∙ 10-3 3.058 ∙ 10-3

30º 1.101 ∙ 10-3 - 0.181 3.297 ∙ 10-3 3.245 ∙ 10-3 3.243 ∙ 10-3

45º 1.002 ∙ 10-3 - 0.252 3.741 ∙ 10-3 3.620 ∙ 10-3 3.621 ∙ 10-3

= cov(λ,κ)

excellent agreement, even for the worst case of 0.75 m projected

helix radius (1GeV/c @ 4T)

only small difference

Page 16: and comparison with an exact Kalman filter

16Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Discussion of the covariance

• Problem: can’t get a1,2 from e.g. Gluckstern’s formulae, because cov(λ,κ) = 0 in the symmetry plane z = 0

• Neglect small difference between σ(Δpt/pt) and σ(Δp/p)

• Large external lever arm and traversal of much passive material: assume ρ(λ,κ) → -1

• Determine a1,2 using simulation at λ ≠ 0

A. Einstein: “It’s better to be roughly right than to be precisely wrong.”

Page 17: and comparison with an exact Kalman filter

17Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

• Summation of covariance matrices for MS (which dominates at small pt) and for detector errors:

• Dependence on pt:

Covariance matrix at higher energy

Page 18: and comparison with an exact Kalman filter

18Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Covariance matrix at higher energy

• Covariance matrix due to detector errors:

– var(κ) can be assumed to be constant w.r.t. λ, and cov(λ,κ) can be neglected

– All terms are constant w.r.t. pt down to 5 GeV/c, where multiple scattering dominates by an order of magnitude

Page 19: and comparison with an exact Kalman filter

19Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

• MS in λ:

• MS in φ:

• Derivatives not λ dependent: var(φ) and cov(φ,κ) show same λ dependence as

• cov(λ,φ) can be neglected

Inclusion of azimuthal angle φ

Page 20: and comparison with an exact Kalman filter

20Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Inclusion of azimuthal angle φ

• var(φ) and cov(φ,κ) strongly dominated by MS in φ

• Total MS covariance matrix of kinematic terms (including pt dependence):

• Covariance matrix for detector errors:

Page 21: and comparison with an exact Kalman filter

21Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Summary• Method needs 9 coefficients per detector setup for

detector optimization– 5 to build covariance matrix of multiple scattering– 4 to build covariance matrix of detector errors

• Coefficients determinable using only two single tracks– One low energetic track yielding the coefficients of the

multiple scattering matrix– One high energetic track yielding the coefficients of the

detector error matrix– Both starting at x = 0, y = 0 → independent of φ– Eventually expansion to Perigee parameter and z

Page 22: and comparison with an exact Kalman filter

22Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Summary

• Optimization carried out in plane perpendicular to the magnetic field only– Leave this plane using the λ dependencies – Desired momentum using the pt dependencies

• Prerequisites: – rotational symmetry– invariance w.r.t. translations parallel to magnetic field

(no z dependent resolution in e.g. a TPC)

Page 23: and comparison with an exact Kalman filter

23Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

Summary

• Step 1: Calculate coefficients of CMStot at λ = 0 and

pt = ptref, e.g. from [1]

• Step 2: Calculate coefficients of Cdet at λ = 0, e.g. from [2]

• Step 3: Use λ dependencies to leave the plane perpendicular to the magnetic field

• Step 4: Use pt dependencies for desired momentum• Step 5: Add CMS and CDet

• Step 6: Use the global formula to calculate σ(Δp/p) - neglecting the correction terms or

- assuming ρ = -1 for a long lever arm incl. material

- taking a1,2 from simulation at λ ≠ 0

Page 24: and comparison with an exact Kalman filter

24Analytical study of multiple scattering

SiLC, Geneva, 2 July 2008 M. Regler, M. Valentan HEPHY – OEAW - Vienna

References• [1] R. L. Gluckstern

Uncertainties in track momentum and direction, due to multiple scattering and measurement errorsNuclear Instruments and Methods 24 (1963) 381

• [2] M. Regler, R. FrühwirthGeneralization of the Gluckstern formulas I: Higher Orders, alternatives and exact results Nuclear Instruments and Methods A589 (2008) 109-117

• [3] M. Metcalf, M. Regler and C. BrollA Split Field Magnet geometry fit program: NICOLECERN 73-2 (1973)

• [4] LiC Detector Toy 2.0, info on the web:http://wwwhephy.oeaw.ac.at/p3w/ilc/lictoy/

M. Regler, M. Valentan, R. FrühwirthThe LiC Detector Toy Program Nuclear Instruments and Methods A581 (2007) 553