2 www.dunnair.com.au
Dunnair Quality Engineering SolutionsDunnair is now firmly positioned as a leading supplier to the air conditioning industry.
The name Dunnair is synonymous with high quality products in the commercial air-conditioning industry. Beginning with Dunn Air Conditioning in 1961 and more recently, Dunnair International and Dunnair Australia, the company continues to be a leading supplier of air-conditioning units for the Australian market.
In 1994, the company was bought by Multistack and renamed Dunnair International. In 2004, Ernest Ugazio acquired the sales and subsequently state service department of Dunnair. This led to the company being divided into separate entities: Dunnair International and Dunnair Australia, the former focused on Multistack Chiller sales and spare parts; while the latter began design and development of a split ducted and rooftop packaged range that was manufactured in China. More recently, in April 2018, Air Change Group acquired Dunnair Australia, solidifying Dunnair's position as a manufacturer of high quality, specified air conditioning units.
The Air Cooled series of split ducted units shown in this brochure are part of Dunnair’s range of high quality units for every application. Dunnair has also become the first choice when individual engineering solutions are required. Fast-moving and responsive, Dunnair supplies made-to-measure HVAC solutions to a growing number of high profile developments across Australia.
Dunnair research and development plus a strict quality control program have been fundamental to our growth, success and reputation. Dunnair units are manufactured in accordance with strict quality control standards and are MEPS rated and developed for Australian conditions.
Range: Dunnair’s modern factories manufacture 16 separate product lines and some 600 different models. Dunnair can supply most products the HVAC industry requires. The recent acquisition by Air Change, a company known for it's award winning innovation, is proof that the company is working continuously to improve its product range and the efficiency of its products.
Specialised Solutions: Dunnair will engineer and manufacture equipment to suit the application and building design. No challenge will go unaccepted. We will design and make special products as required for the building, mining, transport and maritime industry. We employ mechanical engineers in all sales offices in Australia. Their role is to supporting designers to achieve their goals.
Our promise to system designers is: “Tell us what you need and we will work with you to deliver”.
With a head office in Sydney, Dunnair also has offices in Victoria and Queensland. Dunnair maintains a dedicated engineering and sales support staff waiting to assist you with technical and product information and provide valuable solutions for your project.
Dunnair will design, build and deliver HVAC equipment to meet the most stringent specifications and difficult applications.
“We make special equipment.”
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 3
Features • SHS6 to 35 single stage
• SH40 to 200 two stage
• Optional two stage available for 18 kW to 35 kW
• SHS6 to 35 direct drive
• SH40 to 200 belt drive
• Automatic De-Ice
• Liquid Accumulator
• Dry Filter
• Crankcase heater
• 24 volt control
• Galvanised steel panelling
• Durable powder coated cabinet (outdoor unit)
• External stainless steel fittings
• Easy access panels with turn lock handles, no screws
• 25 mm insulation
• Coil corrosion protection
• High quality scroll compressors
• High/low pressure protection for compressor
• Time delay protection for compressor
• Limit start timer
• Quiet & efficient
• Independent defrost dual circuit units for two stage units
• Phase reverse protection
• Optional electric reheat high temperature protection
• Overload protection for both indoor and outdoor fan motor
• MEPS rated
• Manufactured for Australian Standards & Conditions
• High quality control procedures
• R410a refrigerant is used in standard units. Units with R407c refrigerant are available on request
4 www.dunnair.com.au
Optional FeaturesAs an active market player in the commercial air conditioning industry, we understand that every project is unique. Standard manufactured units may not meet the requirements of your system design.
Dunnair always welcome enquiries for custom made air conditioning equipment.
Available options are listed below:
• Stainless steel condensate tray
• 50 mm insulation
• Electric heating fitted to cooling-only models
• Higher external static pressure up to 500 pa
• Two stages or more dependent on unit size
• Belt drive instead of direct drive fan
• Copper fins
• Vertical fan coil units
• EC motor
• EC plug fan
• Other Customised options available. Please contact your local Dunnair sales office
Optional Controller
DAT – 770 multifunction thermostatTechnologically advanced in design and performance, the DAT – 770 is the ideal thermostat control for any installation of air conditioning systems.
Features include: • Auto season change over
• Select programmable or manual mode
• Heat cool or heat pump (O/B) logic
• 0-10 V output option for heating or cooling
• High & Low balance points
• Single or three-speed fan control
• Keyboard and/or temperature locks
• Occupancy sensor inputs
• Programmable occupancy inputs
• Adaptive recovery (Optimised start)
• Smart fan logic for commercial control
• PIN protected menus (installer PIN)
• Outside air temperature display
• 24 V powered with memory backup
• Volt free (clean contact) relays
• Large backlit EL display
• Remote temperature sensors available
• Integrated Modbus option
• Replaces most 24 V thermostats
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 5
Specifications
Models SHS6 – SH200
Model
Capacities (kW) Nominal Levels
Power Phase
Unit Noise Levels (dBA)
Fan DriveRefrigerant
CircuitsTotal Cooling
Sensible Cooling
HeatingAir Flow
(L/s)
Max Current
(A)Indoor Outdoor
SHS6 5.8 5 5.7 361 11.2
1
47.8 55.5
Direct 1
SHS8 7.8 7.2 7.6 467 10.4 46.5 56.4
SHS10 9.8 8 10.1 611 20.8 48.6 56.7
SHS12 12.2 9.9 12.6 695 14
3
68.4 57.5
SHS15 14.3 13 14.2 840 13.9 61.8 58.2
SHS18 17.2 14.4 17.4 928 16 63.7 59.8
SHS20 19.6 15.7 19.3 1030 17 70.5 73.7
SHS25 24.2 19.3 24.5 1390 22.4 71 74.9
SHS30 30.6 25.4 30.6 1800 25.9 69.8 75.5
SHS35 34.8 28.8 32.4 2000 27.6 70.3 75.3
SH40 39.1 32.6 38 2200 30.8 71.4 75.7
Belt 2
SH45 44.4 36.8 43.5 2700 37.2 72.2 76.2
SH50 48.6 39.8 44.2 2800 41.2 72.8 76.7
SH56 55.6 45 57.4 3000 47.7 72.8 77.1
SH66 65.5 50.9 60.7 3500 54.5 73.1 77.7
SH73 72.8 59.3 66.6 3900 60.6 73.7 78.4
SH80 80.4 65.5 80.7 4300 66.2 74.6 79
SH90 88.5 71 85 4800 74.4 75.5 79.6
SH100 102.2 82.9 98.5 5500 85.2 77 80.6
SH120 117.6 95.2 116.2 6500 98.8 77.1 82.2
SH140 137.8 110.6 132 7500 117.5 77.7 83.3
SH160 156.2 127.5 152.5 8500 133.9 80.1 83.7
SH180 176.8 143.6 169.4 9500 153.2 82.5 85.4
SH200 201.8 164.3 196.2 10500 163.7 82.6 87.2
Cooling Capacity is based on DB 27°C, 19°C WB Entering Air Temperature & 35°C Ambient Temperature
Heating Capacity is based on 21°C DB, Entering Air Temperature
Sound Levels are measured from 1 m of the unit
6 www.dunnair.com.au
Dimensions
Models PHS8–PH200
Model
Outdoor Unit Indoor Unit
Length x Width x Height (mm)
Weight(kg)
Length x Width x Height (mm)
Weight (kg)
SHS6 860 x 310 x 718 65 850 x 620 x 400 50
SHS8 950 x 340 x 840 77 1100 x 620 x 400 56
SHS10 950 x 340 x 840 82 1100 x 620 x 400 58
SHS12 950 x 350 x 950 89 1250 x 620 x 400 65
SHS15 950 x 340 x 1245 105 1400 x 620 x 420 80
SHS18 950 x 340 x 1230 105 1550 x 620 x 420 86
SHS20 950 x 340 x 1230 122 1600 x 620 x 420 90
SHS25 1300 x 950 x 700 241 1650 x 720 x 485 121
SHS30 1300 x 950 x 930 276 1900 x 720 x 485 132
SHS35 1300 x 1000 x 930 282 2100 x 720 x 485 140
SH40 1550 x 1200 x 900 360 1300 x 1200 x 940 220
SH45 1550 x 1400 x 900 365 1500 x 1200 x 940 240
SH50 1800 x 1755 x 910 530 1600 x 1200 x 940 290
SH56 1800 x 1755 x 910 532 1600 x 1200 x 940 290
SH66 1800 x 1755 x 910 535 2000 x 1250 x 1040 410
SH73 1800 x 1755 x 910 538 2000 x 1250 x 1040 412
SH80 1800 x 1803 x 910 615 2200 x 1250 x 1040 485
SH90 1800 x 2080 x 1100 710 2430 x 1350 x 1140 516
SH100 2050 x 2050 x 1350 1100 2150 x 1450 x 1350 620
SH120 2050 x 2050 x 1350 1170 2300 x 1550 x 1550 660
SH140 2050 x 2050 x 1750 1180 2650 x 1600 x 1550 730
SH160 2050 x 2050 x 1750 1250 2850 x 1800 x 1550 760
SH180 2150 x 2200 x 2350 1340 3050 x 1850 x 1650 820
SH200 2150 x 2150 x 2350 1400 3050 x 1850 x 1650 860
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 7
Fan Curves
Air Handling Performance
Nominal Airflow
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
280 320 360 400 440Airflow
(L/s)
50
100
150
250
200
High
Medium
Low
SHS6
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
390 430 470 510 550
50
100
150
250
200
High
Medium
Low
SHS8
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
430 470 510 550 590
50
100
150
250
200
High
Medium
Low
SHS10
High
Medium
Low
500 600 700 800 900
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
50
100
150
250
200
SHS12
640 740 840 940 1040
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
50
100
150
250
200
High
Medium
Low
SHS15
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
730 830 930 1030 1130
50
100
150
250
200
High
Medium
Low
SHS18
8 www.dunnair.com.au
High
Medium
LowExte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
630 830 1030 1230 1430
50
100
150
250
200
SHS20
50
100
150
200
300
250
990 1190 1390 1590 1790
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal AirflowSHS25
1400 1600 1800 2000 2200
50
100
150
200
300
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal AirflowSHS30
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
1600 1800 2000 2200 2400Airflow
(L/s)
Nominal Airflow
50
100
150
200
300
250
SH35
50
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
1600 1800 2000 2200 2400 2600 2800Airflow
(L/s)
Nominal Airflow
2.2 kW Motor Limit
SH40
50
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
2100 2300 2500 2700 2900 3100 3300Airflow
(L/s)
Nominal Airflow
3.0 kW Motor Limit
SH45
Fan Curves
Air Handling Performance
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 9
50
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
2200 2400 2600 2800 3000 3200 3400Airflow
(L/s)
Nominal Airflow
3.0 kW Motor Limit
SH50
50
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
2400 2600 2800 3000 3200 3400 3600Airflow
(L/s)
Nominal Airflow
4.0 kW Motor Limit
SH56
50
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
3100 3300 3500 3700 3900 4100 4300Airflow
(L/s)
Nominal Airflow
4.0 kW Motor Limit
SH66
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
4.0 kW Motor Limit
3400 3500 3800 4000 4200 4400 4600
50
100
150
200
300
350
400
250
SH73
450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
4.0 kW Motor Limit
3500 3700 3900 4100 45004300 4700 51004900
SH80450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
5.5 kW Motor Limit
4200 4400 4600 4800 52005000 5400 58005600
SH90
10 www.dunnair.com.au
450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
Airflow(L/s)
Nominal Airflow
7.5 kW Motor Limit
4400 4675 4950 5225 57755500 6050 66006325
SH100 Nominal Airflow
450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
5200 5525 5850 6175 68256500 7150 78007475Airflow
(L/s)
7.5 kW Motor Limit
SH120
450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
3200 4500 5500 6500 7500 95008500 10500 11500Airflow
(L/s)
Nominal Airflow
11 kW Motor Limit
SH140 Nominal Airflow
450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
4500 5500 6500 7500 8500 105009500 11500 12500Airflow
(L/s)
15 kW Motor Limit
SH160
450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
5500 6500 7500 8500 9500 1150010500 12500 13500Airflow
(L/s)
Nominal Airflow
15 kW Motor Limit
SH180450
100
150
200
300
350
400
250
Exte
rnal
Sta
tic
Pre
ssur
e(P
asca
ls)
6500 7500 8500 9500 10500 1250011500 13500 14500Airflow
(L/s)
Nominal Airflow
15 kW Motor Limit
SH200
Fan Curves
Air Handling Performance
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 11
Wiring Diagrams
KM1-3 Contactor
TR Transformer
PU1/2/3 Fuse
PRF Phase Protection
DF1 De ice
VAR Varistor
KT1 Time Relay
C1–3 Capacitor
KA1 Fault Relay
RC1-3 Filter
RV1 Reversing valve
HP/LP HP/LP switch
CM1 Compressor
FM1 Condenser fan
EM Evaporator fan
SH1 Sump heater
BR1 Bypass Relay
SHS6–10
SHS12–20
Outdoor Unit
L1NE
H1M1
W1
CMW
C2
U
FM1
Black
RedBrownBlue
Earth electrode
U1
L1
EN
H1
Indoor Unit
M1
240V50HZ
KM1 KA2
E
PU1
C1
PU2L21
24V
θ PU3KM1SH1
AC100
HP
RV1
BR1
H
KM1
RHRH
RM
T
CKT1
1
12
12
3
2 6
RM
VAR
RLRL
NC COM
M1N
DF1
BR1 105 9
A1 A2
A1 A2
A B
A B
A B
A B
L1M1
C3EMH1
RL
RMRH
N
6
54
6
54
6
5 LP5
L
RC1
1P
KA2
KM1
Outdoor Unit
L1NE
H1M1
W1
CMWU
FM1
Black
RedBrownBlue
Earth electrode
U1V1
L1
EN
H1
Indoor Unit
M1
240V50HZ
KM1
W
C2
U
FM2
KA2
E
ABCN
PU1
C1
PU2L21
24V
θ PU3KM1SH1
AC100
HP
TR
RV1
BR1
H
KM1
RHRH
RM
T
CKT1
1
13
7
73
2 6
RM
VAR
RLRL
NC COM
M1N
DF1
BR1 10
13 14
A1 A2
A1 A2
A B
A B
A B
A1 A2
L1M1
C3EMH1
RL
RMRH
N
6
54
6
5
5
9
6
10
3
4
1
2
6
54
6
5LP5
L
RC1
1P
KA2
KM1
PRF
PRFL1 L2 L3
com
on
12 www.dunnair.com.au
SHS25–35
QF1-3 Motor Overload Breaker
KM1-5 Contactor
FR Thermal Relay
TR Transformer
PU1/2/3 Fuse
DF1/DF2 De ice
VAR Varistor
KT1-2 Time Relay
PRF Phase Protection
C1- 3 Capacitor
KA1-2 Fault Relay
RC1-5 Filter
RV1/RV2 Reversing valve
TK1-4 Overload protector
TK5-6 Disch temp sensor
L/HP1 HP/LP switch
CM1-2 Compressor
FM1-4 Condenser fan
EM Evaporator fan
SH1-2 Sump heater
BR1-2 Bypass Relay
Outdoor Unit
WE
UV
WE
UV
W1
CM1 FM1
RedWhiteBlue
RedWhiteBlue
Earth electrode
U1V1
W3U3V3
Indoor Unit
KM1KM3
QF1Set:16AE
ABCN
PU1PU2
L21
24V
θ PU3KM1SH1
AC100
HP1
TR
RV1
KM1
H1
T
C1KT1
TK11
13
18
21
12
12
5
VAR
NC COM
M1N
DF1
BR1 14
KM2
SH2 101
13 14
1 3A1 A26
5
3
4
1
26
5
3
4
1
2
LP17
L
RC1KM1
PRF
VU W
PRF
FR
L1 L2 L3
com
on
Three phase five line415V 50Hz 3P
W2
CM2 FM2
EM
U2V2
W4U4V4
KM2KM4
QF2
QF3
Set:16A
Set:5A
6
5
3
4
1
26
5
3
4
1
2
6
5
3
4
1
2
21
22
21
22
HP2C2KT2
TK22 22
3 9
61 3
6 10
A1 A2LP28
RC2KM2
A1 A2
A1 A2
BR2A1 A2
RC3KM3
RV2
KM2
H2
EF
12
NC COM
M2N
DF2
BR2 16
13 14
L
4 15
6 10
A1 A2
A1 A2
BR2A1 A2
RC4KM4
A1 A2
RC5KM5
Wiring Diagrams
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 13
SH40-45
QF1-3 Motor Overload Breaker
KM1-5 Contactor
FR Thermal Relay
TR Transformer
PU1/2/3 Fuse
DF1/DF2 De ice
VAR Varistor
KT1-2 Time Relay
PRF Phase Protection
C1- 3 Capacitor
KA1-2 Fault Relay
RC1-5 Filter
RV1/RV2 Reversing valve
TK1-4 Overload protector
TK5-6 Disch temp sensor
L/HP1 HP/LP switch
CM1-2 Compressor
FM1-4 Condenser fan
EM Evaporator fan
SH1-2 Sump heater
BR1-2 Bypass Relay
Outdoor Unit
WE
UV
WE
UV
W1
CM1 FM1
RedWhiteBlue
RedWhiteBlue
Earth electrode
U1V1
W3U3V3
Indoor Unit
KM1KM3
QF1Set:17AE
ABCN
PU1PU2
L21
24V
θ PU3KM1SH1
AC100
HP1
TR
RV1
KM1
H1
T
C1KT1
TK11
13
18
21
12
12
5
VAR
NC COM
M1N
DF1
BR1 14
KM2
SH2 101
13 14
1 3A1 A26
5
3
4
1
26
5
3
4
1
2
LP17
L
RC1KM1
PRF
VU W
PRF
FR
L1 L2 L3
com
on
Three phase five line415V 50Hz 3P
W2
CM2 FM2
EM
U2V2
W4U4V4
KM2KM4
KM5QF2
QF3
Set:17A
Set:6.8A
6
5
3
4
1
26
5
3
4
1
2
6
5
3
4
1
2
21
22
21
22
HP2C2KT2
TK22 22
3 9
61 3
6 10
A1 A2LP28
RC2KM2
A1 A2
A1 A2
BR2A1 A2
RC3KM3
RV2
KM2
H2
EF
12
NC COM
M2N
DF2
BR2 16
13 14
L
4 15
6 10
A1 A2
A1 A2
BR2A1 A2
RC4KM4
A1 A2
RC5KM5
13
14
14 www.dunnair.com.au
QF1-3 Motor Overload Breaker
KM1-5 Contactor
FR Thermal Relay
TR Transformer
PU1/2/3 Fuse
DF1/DF2 De ice
VAR Varistor
KT1-2 Time Relay
PRF Phase protection
KA1-2 Intermediate relay
KA3-4 Fault Relay
RC1-5 Filter
RV1/RV2 Reversing valve
TK1-4 Overload protector
TK5-6 Disch. temp. sensor
L/HP1-2 HP/LP switch
CM1/CM2 Compressor
FM1-4 Condenser fan
EM Evaporator fan
SH1-2 Sump heater
BR1-2 Bypass Relay
SH50–73
Outdoor Unit
WE
UV
WE
UV
W1
CM1 FM1
RedWhiteBlue
RedWhiteBlue
Earth electrode
U1V1
W3U3V3
Indoor Unit
KM1 KM3
QF1E
ABCN
PU1PU2
L21
24V
θ PU3
KM1
SH1
AC
100
HP1
TR
RV1
KM1
H1
T
C1KT1
TK11
13
18
21
12
12
23 25
VAR
NC COM
M1N
DF1
BR1 14
KM2 KA1 KA2
SH2101
13 14
1 3A1 A26
5
3
4
1
2
6
5
3
4
1
2
LP15
L
KA1
PRF
VU W
PRF
FR
L1 L2 L3
FM2W3U3
V3
FM4W4U4
V4
com
on
13
14
Three phase five line415V 50Hz 3P
W2
CM2 FM3
EM
U2V2
W4U4V4
KM2 KM4
KM5QF2
QF3
Set:24.5ASet:24.5A
Set:11.6A
6
5
3
4
1
2
6
5
3
4
1
2
6
5
3
4
1
2
21
22
21
22
5
9
5
9
TK2 TK5
HP2KT2
TK32 22 24 25
19 20
1 3A1 A2LP26
7
8KA2
TK4 TK6C2
3 9
6 10
A1 A2
A1 A2
BR2A1 A2
RC3
RC1 RC2
KM3
RV2
KM2
H2
EF
12
NC COM
M2N
DF2
BR2 16
13 14
L
4 15
6 10
A1 A2A1
A2
A1
A2
A1 A2
BR2A1 A2
RC4KM4
A1 A2
RC5KM5
KM1 KM2
Wiring Diagrams
Air Cooled Split Ducted Air Conditioners
www.dunnair.com.au 15
QF1-3 Motor Overload Breaker
KM1-5 Contactor
FR Thermal Relay
TR Transformer
PU1/2/3 Fuse
DF1/DF2 De ice
VAR Varistor
KT1-2 Time Relay
PRF Phase Protection
KA1-2 Intermediate relay
KA3-4 Fault Relay
RC1-5 Filter
RV1/RV2 Reversing valve
TK1-4 Overload protector
L/HP1-2 HP/LP switch
CM1 /CM2 Compressor
FM1-4 Condenser fan
EM Evaporator fan
SH1-2 Sump heater
BR1-2 Bypass Relay
TK5 Compressor protect
SH80–200
W1
CM1 FM1U1
V1W3U3
V3
KM1FR1 FR2
KM3
QF1E
ABCN
PU1PU2
L21
24V
θ PU3
KM1
SH1
AC
100
HP1
TR
RV1
KM1
H1
T
C1KT1
TK11
13
18
21
12
12
23 25
VAR
NC COM
M1N
DF1
BR1 14
KM2 KA1 KA2
SH2101
13 14
1 3A1 A26
5
3
4
1
2
6
5
3
4
1
2
LP15
L
KA1
PRF
V5U5 W5
V5U5 W5
PRF
FR
L1 L2 L3
FM2W3U3
V3
FM4W4U4
V4
com
on
13
14
Three phase five line415V 50Hz 3P
W2
CM2 FM3U2
V2W4U4
V4
KM2 KM4
KM5
KM7
KM6
QF2
QF3
Set:37ASet:37A
Set:11.6A
6
5
3
4
1
2
6
5
3
4
1
2
6
5
3
4
1
2
21
22
21
22
5
9
5
9
TK2 TK5
HP2KT2
TK32 22 24 25
19 20
1 3A1 A2LP26
7
8KA2
TK4 TK6C2
3 9
6 10
A1 A2
A1 A2
BR2A1 A2
RC3
RC1 RC2
KM3
RV2
KM2
H2
EF
12
NC COM
M2N
DF2
BR2 16
13 14
L
4 15
6 10
A1 A2
A1
L1 L2
L21
L3
L N
N
B1 B2
26 6
11M2
A2
A1
A2
A1 A2
BR2A1 A2
RC4KM4
A1 A2
RC5KM5
A1 A2
RC7KM7
KM1 KM2
Outdoor Unit
WE
UV
WE
UV
RedWhiteBlue
RedWhiteBlue
RedWhiteBlue
Earth electrode
Indoor Unit
EM
W
UV
W
UV
RedWhiteBlue
6
5
3
4
1
2
6
5
3
4
1
2
KT3309 211
KM631
32
22
A1 A2
RC6KM6
KT3KT3TK6 339 215
KM7
S6
3422
31KM6
32
13KM6
14
13 14SY380 Overload Protector inner compressor
240V AC
L1 L2
L21
L3
L N
N
B1 B2
25 6
11M2
TK5
240V AC
www.dunnair.com.au
201808DUNACRTP
DUNNAIR (Aust) Pty Ltd
Head Office:Ashford Avenue, Milperra NSW 2214 p 02 8774 1403 f 02 8774 1490 e [email protected] w www.dunnair.com.au
Dunnair Victoria:p 03 9558 7001 f 03 9551 1644 e [email protected]
Dunnair Queensland:p 07 3890 8796 f 07 3890 8642 e [email protected]
For sales in SA, NT or WA please contact our distributor Industrial Air on 08 8354 0088
Dunnair (Aust) Pty Ltd supports a policy of continuous product improvement. Therefore specification and designs are subject to change without prior notice. Dunnair (Aust) Pty Ltd accepts no responsibility for possible errors in Catalogues, brochures and other printed material.Dunnair is part of the Air Change Group of companies.