2
All leaflets are available on: www.asconumatics.eu PIC-13-20-GB 80414GB-2012/R02 Standard assemblies or engineered for the application Full range of components, highly configurable! ACTUATOR CONTROL SYSTEM ACS Reliable, industry proven solenoid technologies Unique versatile coupling system All major hazardous area approvals available. Solenoid valves TUV certified to IEC 61508, can be used up to SIL 4 Actuator Control System Benefits: • Corrosion resistant due to the use of 316L Stainless steel throughout • System engineered by ASCO Numatics freeing up engineering time • All components mounted on stable, vibration resistant panel easing installation • One flow factor for the complete system enabling fast and easy determination of actuator speed • Modular assembly enables infinite number of variations to suit any application • Can incorporate any threaded component demanded by the application • Uses standard, industry proven components to ensure reliability • Unique coupling system independent of thread tolerances, enabling easy component interchangeability and maintenance

Actuator Control System choices

Embed Size (px)

DESCRIPTION

Select your ASCO Numatics Actuator Control System based on standard solutions or engineered for the application

Citation preview

All leaflets are available on: www.asconumatics.eu

PIC-13-20-GB

8041

4GB

-201

2/R

02

Standard assemblies or engineered for the application

Full range of components, highly configurable!

ACTUATOR CONTROL SYSTEM ACS

Reliable, industry proven solenoid technologies Unique versatile coupling system

All major hazardous area approvals available.

Solenoid valves TUV certified to IEC 61508, can be used up to SIL 4

Actuator Control System Benefits:• Corrosionresistantduetotheuseof316LStainlesssteelthroughout• SystemengineeredbyASCONumaticsfreeingupengineeringtime• Allcomponentsmountedonstable,vibrationresistantpaneleasing

installation• Oneflowfactorforthecompletesystemenablingfastandeasy

determinationofactuatorspeed• Modularassemblyenablesinfinitenumberofvariationstosuitany

application• Canincorporateanythreadedcomponentdemandedbytheapplication• Usesstandard,industryprovencomponentstoensurereliability• Uniquecouplingsystemindependentofthreadtolerances,enablingeasy

componentinterchangeabilityandmaintenance

All leaflets are available on: www.asconumatics.eu

13-20-2

PIC

-13-

0020

-GB

--

Ava

ilabi

lity,

des

ign

and

spec

ifica

tions

are

sub

ject

to c

hang

e w

ithou

t not

ice.

All

right

s re

serv

ed.

8041

4GB

-201

2/R

02

ACTUATOR CONTROL SYSTEMACTUATOR CONTROL SYSTEM

GENERAL• Availablein1/4” and 1/2” sizes• Full 316L stainless construction• Systemwillbedesignedtomeetthemaximumpossiblepressuresandtemperaturesoftheapplication• Allmaterialsofconstructionwillbeselectedbasedonthestatedatmosphericconditionsandflowingmediaoftheapplication• AnystandardthreadedcomponentcanbeincorporatedintotheActuatorControlSystem(asummarylistofstandard

componentsisshownbelow)

Filter regulatorToregulatetheinletpressuretotheactuatorcontrolsystemandfiltertheflowingmedium

Non return valveTopreventtheflowofmediumfromtheactuatorintotheupstreampipingintheeventofalossofupstreampressure

Speed controllerToadjustactuatoropeningorclosingspeedstomeettheneedsoftheapplication

TeeUsedtoinstalladditionalcomponentsinthesystemorwhenasecondarysourceofregulatedpressureneedstobesuppliedtoanyancillarycomponents

Pressure relief valveTopreventtheactuatorbeingover-pressurisedintheeventofapressuresurgeorfailureofthefilterregulator

3/2 Solenoid valveManydifferent3/2solenoidvalvescanbeinstalleddependentonthepressure,temperature,requiredflowrateandelectricalclassification

5/2 Solenoid valveManydifferent5/2solenoidvalvescanbeinstalleddependentonthepressure,temperature,requiredflowrateandelectricalclassification

Isolation valveCanbeusedanywhereinthesystemtoisolateindividualcomponents,toisolatetheActuatorControlSystemfromtheupstreampressureortoisolatetheactuatorfromtheActuatorControlSystem

Pressure gaugeUsedforalocalindicationofpressure(requiredforcommissioning,maintenanceortrouble-shooting)

Quick exhaust valveUsedwhenthereisarequirementfortheactuatortomovetoafail-safeorotherspecifiedpositionwithinaspecifiedtimeandthedesiredexhaustratecannotbeachievedbyusingtheexhaustportofthesolenoid