58
ACM1 Stefan Askenfors ACM AB Järfälla (Stockholm) Sweden www.acmab.com ACM AB, Drakvägen 8, SE-175 65 JÄRFÄLLA, Sweden Tel +46 -8 892715 E-mail [email protected] Fax +46 -8 893750

ACM1 Stefan Askenfors ACM AB GB.pdf · Ref 2 COFICAB, Europe and Africa 5 units Commscope - Catawba - NC - USA Conductores - Monterrey - Mexico Copperfield LLC - Bremen, IN - USA

Embed Size (px)

Citation preview

ACM1

Stefan AskenforsACM AB

Järfälla (Stockholm) Sweden

www.acmab.comACM AB, Drakvägen 8, SE-175 65 JÄRFÄLLA, Sweden

Tel +46 -8 892715 E-mail [email protected] Fax +46 -8 893750

ACM Program

ACM AB, Drakvägen 8, SE-175 65 JÄRFÄLLA, SwedenTel +46 -8 892715 www.acmab.com [email protected] Fax +46 -8 893750

Representing

ACM KSM

Automatic Measuring ofCable Slices

KSM Kabel

KSM KabelOff line

Measuring System

for Cables

CCD Camera

Cable slices are viewed by the CCD Camera in

the top of the Box

Round1 IEC 811-1-1

Measured in 1 Sec.

Optic Advantages

1. Long distance CCD Camera/optic -Cable slice

2. Optic locking down – no dust3. Fixed optic (zoom distortion)4. Not locking through glass Fish

Box Advantages1. Protection from outside

disturbing Light2. Fixed back light3. Adjustable over light for non

translucent samples4. Light overpressure via Filter5. Strong total even glass bottom6. Samples slide easy

on a measure glass7. Weight glass for XLPE cables

with built in tension

Round3 AEIC

Measured in 5 Sec.

Round3 IEC 811-1-1

Measured in 5 Sec.

Round2

Measured in 2 Sec.

Black/Red Rubber

Transparent outer layer

POF

Measuring Advantages

1. 20 year experiences of cable measuring2. Not measuring from the centre3. Knowledge of norms4. Co-operation with 11 Test institutes5. Ready to use applications “Boss proof”6. Continues development and update

service7. Our first unit still running and updated

Result LDB RG

KSM RL5

KSM R2L4

R1-90 Centring

Start up help by extrusion

12 O'clock

Green/Yellow %

Green/Yellow circumference % and stripes

Sector

R2_1 S2_1

Round, Lynen, Band cable

Skin Foam Skin

SLOT

KSM2 New Programs

KSM2 New Measure Programs

RG+OPAutomatic selection Open/Closed sample

RL+OP

S1+OPAlso refer to the complete list of programs

KSM2 New Programs

MDManual measurement

CM1Aut. measure after calibration

KSM2 New Measure Programs

OHMCollect resistance and present trend curves. Also as a separate program for the stranding department. A KSM without “KSM”

FI82Figure8 with dual part

Advantages KSM

•Measure equally bad each timevery good repeat accuracy

•The same values independent who is measuring

•Very quick and easy to usemeasurements take seconds. Even the boss can do it!

•Can be located by the production line•Splendid help for centring

reduces start scrap.•Measured values are stored at the server

eliminates wrongly keyed data

Ref. 20 year

ABB HV Cables - Karlskrona – SE 2 unitsABB Moskabel - RUAberdare Cables – ZA 3 units ACOME – Mortain - FRAMO Kabel - Alstermo - SE 4 unitsAMELCO - Noida - INBelden CDT – Örebro – SE 2 unitsBerkenhoff & Drebes - Aßlar - DE Brugg Kabel - CH B.S.I. - GB The British Board of ControlCentelsa - Cali – Colombia 2 unitsCBI Electric, AFC – Vereeniging - ZACNA Techn. – Grenville - NC - USA

Ref 2

COFICAB, Europe and Africa 5 unitsCommscope - Catawba - NC - USAConductores - Monterrey - MexicoCopperfield LLC - Bremen, IN - USA 4 unitsDEMKO (UL) - DK The Danish Board of Control DEVI – DK + PL 2 unitsDraka Cables – Barcelona – ES 3 units Draka Netherland - NL 6 unitsDraka Kabel - Nässjö - SE 2 unitsDraka Kabel - Ystad - SE 3 unitsDraka NK Cables - Oulu - FIN 2 unitsDraka Norsk Kabel - Drammen – NO 4 unitsDubai Cables - Dubai and Abu Dhabi 11 units

Ref 3

Elkabel JSC - Bourgas – BGEnt. De (General Cables) , BISKRA, ALEricsson Cables – SE 8 unitsEZU - Praha - CZ The Czech Board of ControlFIMKO - Helsinki - FIN The Finish Board of Control General Cables – Christchurch – NZHelkama Kaapeli – Kaarina - FINHelkama Kaapeli – Hanko – FINHelkama – Shanghai – ROCHuber+Suhner, Pfäffikon, CH 2 unitsImacab – Casablanca - MA Interamericana - Valencia - VN 3 unitsIntertek SEMKO – Stockholm - S The Swedish Board of Control

Ref 4

Jeddah Cable – Jeddah – SAJordan New Cable – Mafraq . JOKabelwerke EHLERS -Hamburg – DEKabelwerke Eupen – BE 2 units Kablo Bratislava (Prysmian) – SL Kablo Velke Mezirici - CZKablo Vrchlabi - CZKEMA - Arnhem – NL The Dutch Board of ControlKromberg & Schubert - Rhede - DELABCo - Brake/Unterweser - DE Test LabMiguelez – Leon - ESNK Keila Kaabel - Tallin – EE (Draka)N K T - Asnæs - DK 5 units

Ref5

N K T Kablo Kladno - CZN K T Cables - Warszowice – PLNEMKO - N The Norwegian Board of ControlNexans - Chester NY - USANexans Benelux - Charleroi – BE 2 unitsNexans - Fergus - CDNNexans France - FR 8 unitsNexans Maroc - Mohammedia - MA Nexans IKO - Grimsås – SE 5 unitsNexans Norway - Halden - NONexans Norway - Namsos - NO Nexans Norway - Rognan – NO 2 units

Ref6

Nexans Romania - Arad – RONexans Suisse – Cortaillod - CHOLEX – Lilydale and Tottenham – AUS 5 unitsPrysmian Cables - GB 3 unitsPrysmian Cables - Charvieu – FRPrysmian Cables - Pikkala - FIN 2 unitsPrysmian Cables - Schwerin - DE 2 unitsREKA Cables - FIN 3 unitsSEV – Fehraltorf -CH The Swiss Board of ControlTele-Fonika - PL 6 unitsVDE - Offenbach – DE The German Board of Control

Many different programs

Used by test institutes such as BSI, KEMA, SEV, EZU, DEMKO (UL), FIMKO, LABCo, NEMKO, SEMKOand VDE

KSM to measure Cables, Tubes, Dies and Extruder Dies

175 units delivered

Calibration

Calibration procedureand calibrators are supplied. Also verification (daily control function) are available

KSM Replacing

The fully automatic KSM

is replacing manual Profile projectors and microscopes

Repeat accuracy

KSM has a repeatableaccuracy of 0,2%

Manual methods has a spread of at least 5%

Manual measuring

5-7 %

Automatic methods

0.2 %

KSM Automatic

KSM Economics

Old method

Spread

Test made also by several cable plants

show a spread of measuring values

typically to be 7 - 9%.

Manual measuring

5-7 %

Automatic methods

0.2 %

KSM Automatic

Over dimension

5 %extra material not paid for!!!

34 years ago profit on cables was very good

34

Now with lower prices we must reduce cost to make a profit

Lower

Material

Others MachineryLabour

The major cost factor, MATERIAL

Major

Over dimensions,mainly due to too high radial thickness

Over dim $

Database

Compare with Specification

Stored Reference values

Select the production line and the last used cable type will automatically be selected and measured again. Comparing measured values to reference.

Compare

Measured values will automatically be comparedwith reference values and deviations will be noted

Trend

Curve min and average with reference values and over dimensional costs will be presented

Ref. Wall average max

Ref. Wall average min

Ref. Wall min min

Database Advantages

1. Integrated measuring data base with summery report functions

2. Specification database3. Remote functions in operation in 15 year4. Automatic Trend curves5. Automatic OD Calculation

KSMEval

Analyse KSM data and calculate Total Over dimensional cost at the Office

Wall min Tot Over

Total over dimensional cost analyse= $

WHY IS THE CABLE INDUSTRY GIVING AWAY

SO MUCH MONEY?

Why2

Buy kg/pound

Make many m/”

AESA 7197

AESA Resistance meterconnected to KSM controlling stability of the values incorporating them into the KSM protocol

AESA New Resistance meter

Resistance meter 7197ET with knives for 0.5 m sample

ACM2

ACM ABJärfälla

(Stockholm) Sweden

www.acmab.comlinks to our suppliers and reps

ACM AB, Drakvägen 8, SE-175 65 JÄRFÄLLA, SwedenTel +46 -8 892715 E-mail [email protected] Fax +46 -8 893750