ACM & LBP SURVEY PERCY D. MILLER WATER TREATMENT PLANT
OPERATIONS & MAINTENANCE BUILDING RENOVATIONS 32 PENCE LANE ROAD
MIDDLETOWN, VIRGINIA 22645
TRIAD PROJECT NO. 07-19-0037
Submitted to:
PAINTER-LEWIS, P.L.C. Attn: Mr. Timothy G. Painter, PE 817 Cedar Creek Grade, Suite 120
Winchester, Virginia 22601
Submitted by:
TRIAD ENGINEERING, INC. 200 Aviation Drive
Winchester, Virginia 22602
____________________________________________
Jeffrey H. Mitchell, CPG Senior Environmental Geologist
February 26, 2019
ACM & LBP Survey Percy D. Miller WTP – Operations & Maintenance Building Renovations
February 26, 2019 Page i
TABLE OF CONTENTS
Page
AREA EVALUATION ................................................................................................................1
ACM SURVEY ...........................................................................................................................1
LBP SURVEY .............................................................................................................................3
USE OF REPORT ........................................................................................................................3
ATTACHMENTS 1. Asbestos Inspector and Laboratory Licenses 2. SACM Chain of Custody & Asbestos PLM Analytical Result Documentation 3. DMY LBP Survey Report 4. Photographs
LIST OF ACRONYMS
ACM Asbestos-Containing Material
COC Chain of Custody
LBP Lead-Based Paint
NESHAP National Emission Standard for Hazardous Air Pollutants
NVLAP National Voluntary Laboratory Accreditation Program
PLM Polarized Light Microscopy
SACM Suspect ACM
TCLP Toxic Characteristic Leaching Procedure
USEPA United States Environmental Protection Agency
ACM & LBP Survey February 26, 2019 Percy D. Miller WTP – Operations & Maintenance Building Renovations Page 1
ACM & LBP SURVEY PERCY D. MILLER WATER TREATMENT PLANT
OPERATIONS & MAINTENANCE BUILDING RENOVATIONS 32 PENCE LANE ROAD
MIDDLETOWN, VIRGINIA 22645
AREA EVALUATION
On February 12, 2019, Jeffrey H. Mitchell of Triad Engineering, Inc. (Triad) and Brandon J.
Colunga of DMY Capital LLC (DMY) conducted an asbestos-containing material (ACM) and
lead-based paint (LBP) survey of the interior portions of the Operations Building proposed for
renovation, which were identified by Mr. Farrell Owens, the Facility Manager, and the roofs of
the Operations and Maintence Buildings located at the Percy D. Miller Water Treatment Plant
addressed as 32 Pence Lane Road, Middletown, Virginia 22645.
ACM SURVEY
The ACM survey was performed by Jeffrey H. Mitchell; Asbestos Inspector Licensed by the
Virginia Department of Professional and Occupational Regulation (Attachment 1).
Following standard inspection practices, suspect ACM (SACM) samples were collected to
confirm the presence or absence of asbestos. Samples were collected from locations of SACM
using the following procedures: utilizing appropriate tools, a sufficient amount was obtained for
PLM analysis; each SACM sample was placed individually in a sealed bag; and a unique sample
identification number was assigned to each sample material and location.
As follows are the specific SACMs identified and sampled:
Roofing: roofing system layers, sealant, and caulk;
Interior Wall: ceramic tile and grout;
Windows: interior & exterior caulk;
HVAC Systems: caulk; and
Miscellaneous: fiberglass pipe insulation mastic.
SACM descriptions and locations are listed on the chain of custody (COC) documentation
included in Attachment 2. Photographs are included as Attachment 5.
ACM & LBP Survey February 26, 2019 Percy D. Miller WTP – Operations & Maintenance Building Renovations Page 2
Following standard inspection practices, Triad obtained a sufficient number of samples of the
suspect materials per the federal and state regulations to confirm the presence or absence of
asbestos fibers in the SACMs. Samples of the SACMs were collected using the following
procedures: utilizing appropriate tools, a sufficient amount of a suspect material was obtained for
PLM analysis; each suspect sample was placed individually in a sealed bag; and a unique sample
identification number was assigned to each sample material and location.
The friability characteristics of the material were also evaluated by the inspector during the
sampling and procuring process. The friability of the material is described in two ways. A
designation of “friable” describes material meeting the following characteristics as described in
the U.S. Environmental Protection Agency (USEPA) National Emission Standard for Hazardous
Air Pollutant (NESHAP) for Asbestos 40 Code of Federal Regulation Section 61 Subpart M,
61.141: “that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure”.
A designation of “non-friable” describes a material meeting the following characteristics as
described in the USEPA NESHAP: “that, when dry, cannot be crumbled, pulverized, or reduced
to powder by hand pressure.” Please note however that material currently in a non-friable state
could become friable during demolition activities.
During the ACM Survey, a total of 15 sample sets totaling 45 SACM samples were collected and
submitted for asbestos analysis to SanAir Technologies Laboratory, an independent NVLAP
accredited and Virginia-licensed laboratory. Samples were analyzed using polarized light
microscopy (PLM) and dispersion staining analysis methods USEPA 600/R-93/116 and a total of
64 tests were performed due to multiple layers in some samples.
The following material contained asbestos at a level greater than one percent, which by
regulatory definition is an ACM.
Material Sample ID Location & Estimated Quantity Result
Black Caulk 10-A Upper Roof of the Operations Building (Unknown Quantity)
3% Chrysotile
The black caulk on the upper roof of the Operations Building is considered Category I non-
friable ACM.
ACM & LBP Survey February 26, 2019 Percy D. Miller WTP – Operations & Maintenance Building Renovations Page 3
LBP SURVEY
A copy of the LBP survey report prepared by DMY is included as Attachment 4. In summary,
the following items were identified or should be assumed to have a LBP coated surface:
All cream porcelain tiles within the Filter Operating Floor and Rear Entrance Lobby,
All blue paint located on the stair systems and guard rails,
The orange paint located on the I-beams within the columns of the Filter Operating Floor,
and
The red access doors located on the exterior of the Operations Building.
LIMITATIONS
It was attempted to perform an ACM and LBP survey of the interior portions of the Operations
Building proposed for renovation, which were identified by Mr. Farrell Owens, the Facility
Manager, and the roofs of the Operations and Maintence Buildings located at the Percy D. Miller
Water Treatment Plant located at 32 Pence Lane Road, Middletown, Virginia 22645; however,
some areas may have been hidden or impracticable to access. These areas may include, but are
not necessarily limited to, the sub-grade; flooring located below underlayments; above or behind
ceilings, walls, and roofing; and pipe and utility chases.
Any SACMs or suspect LBP coatings encountered during the renovation that were not tested
should be assumed to be ACM or LBP unless tested to determine asbestos or lead content.
USE OF REPORT
This report has been prepared for the exclusive use of the Client and persons or organizations to
which the Client wishes to make this report available. This report and the findings contained
herein shall not, in whole or in part, be used by or relied upon by any other party, without the
prior written consent of Triad.
ASBESTOS INSPECTOR AND LABORATORY LICENSES
SACM CHAIN OF CUSTODY & ASBESTOS PLM ANALYTICAL RESULT
DOCUMENTATION
Page 11 of 12
Page 12 of 12
SanAir ID#: 19006538
Project #: 07-19-0037
Project Name: Winchester WTP
Report Date: 2/20/2019
Analysis Report prepared forTriad Engineering, Inc.
Page 1 of 12
Dear Jeffrey H. Mitchell,
We at SanAir would like to thank you for the work you recently submitted. The 45 sample(s) were received on Wednesday, February 13, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 1-A, 1-B, 1-C, 2-A, 2-B, 2-C, 3-A, 3-B, 3-C, 4-A, 4-B, 4-C, 5-A, 5-B, 5-C, 6-A, 6-B, 6-C, 7-A, 7-B, 7-C, 8-A, 8-B, 8-C, 9-A, 9-B, 9-C, 10-A, 10-B, 10-C, 11-A, 11-B, 11-C, 12-A, 12-B, 12-C, 13-A, 13-B, 13-C, 14-A, 14-B, 14-C, 15-A, 15-B, 15-C.
These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.
Sincerely,
Sandra SobrinoAsbestos & Materials Laboratory ManagerSanAir Technologies Laboratory
Final Report Includes:- Cover Letter- Analysis Pages- Disclaimers and Additional Information
Sample conditions:- 45 samples in Good condition.
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 2 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
1-A / 19006538-001Operations Interior-Ceramic Wall Tile
TanNon-Fibrous
Heterogeneous
100% Other None Detected
1-B / 19006538-002Operations Interior-Ceramic Wall Tile
TanNon-Fibrous
Heterogeneous
100% Other None Detected
1-C / 19006538-003Operations Interior-Ceramic Wall Tile
TanNon-Fibrous
Heterogeneous
100% Other None Detected
2-A / 19006538-004Operations Interior-Ceramic Wall Grout
TanNon-Fibrous
Heterogeneous
100% Other None Detected
2-B / 19006538-005Operations Interior-Ceramic Wall Grout
TanNon-Fibrous
Heterogeneous
100% Other None Detected
2-C / 19006538-006Operations Interior-Ceramic Wall Grout
TanNon-Fibrous
Heterogeneous
100% Other None Detected
3-A / 19006538-007Operations Interior-Upper Windows-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
3-B / 19006538-008Operations Interior-Upper Windows-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
3-C / 19006538-009Operations Interior-Upper Windows-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
4-A / 19006538-010Operations Interior-HVAC Ductwork Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 3 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
4-B / 19006538-011Operations Interior-HVAC Ductwork Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
4-C / 19006538-012Operations Interior-HVAC Ductwork Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
5-A / 19006538-013Operations Exterior-Lower Windows-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
5-B / 19006538-014Operations Exterior-Lower Windows-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
5-C / 19006538-015Operations Exterior-Lower Windows-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
6-A / 19006538-016Operations Lower Roof-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
6-B / 19006538-017Operations Lower Roof-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
6-C / 19006538-018Operations Lower Roof-Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
7-A / 19006538-019Operations Lower Roof-Upper Windows-L. Graye
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
7-B / 19006538-020Operations Lower Roof-Upper Windows-L. Graye
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 4 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
7-C / 19006538-021Operations Lower Roof-Upper Windows-L. Graye
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
8-A / 19006538-022Operations Lower Roof-Sealant
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
8-B / 19006538-023Operations Lower Roof-Sealant
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
8-C / 19006538-024Operations Lower Roof-Sealant
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
9-A / 19006538-025Operations Lower Roof-Roofing System, Roofing
BlackNon-Fibrous
Heterogeneous
40% Cellulose 60% Other None Detected
9-A / 19006538-025Operations Lower Roof-Roofing System, Felt Paper
BlackFibrous
Heterogeneous
75% Cellulose 25% Other None Detected
9-A / 19006538-025Operations Lower Roof-Roofing System, Membrane
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
9-B / 19006538-026Operations Lower Roof-Roofing System, Roofing
BlackNon-Fibrous
Heterogeneous
40% Cellulose 60% Other None Detected
9-B / 19006538-026Operations Lower Roof-Roofing System, Felt Paper
BlackFibrous
Heterogeneous
75% Cellulose 25% Other None Detected
9-B / 19006538-026Operations Lower Roof-Roofing System, Membrane
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 5 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
9-C / 19006538-027Operations Lower Roof-Roofing System, Roofing
BlackNon-Fibrous
Heterogeneous
40% Cellulose 60% Other None Detected
9-C / 19006538-027Operations Lower Roof-Roofing System, Felt Paper
BlackFibrous
Heterogeneous
75% Cellulose 25% Other None Detected
9-C / 19006538-027Operations Lower Roof-Roofing System, Membrane
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
10-A / 19006538-028Operations Upper Roof-Caulk, Roof Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
10-A / 19006538-028Operations Upper Roof-Caulk, Roof Caulk
BlackNon-Fibrous
Heterogeneous
97% Other 3% Chrysotile
10-B / 19006538-029Operations Upper Roof-Caulk, Roof Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
10-B / 19006538-029Operations Upper Roof-Caulk, Roof Caulk
Not Analyzed
10-C / 19006538-030Operations Upper Roof-Caulk, Roof Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
10-C / 19006538-030Operations Upper Roof-Caulk, Roof Caulk
Not Analyzed
11-A / 19006538-031Operations Upper Roof Capstones-L. Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 6 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
11-B / 19006538-032Operations Upper Roof Capstones-L. Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
11-C / 19006538-033Operations Upper Roof Capstones-L. Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
12-A / 19006538-034Operations Interior-Fiberglass Pipe Insulation Mastic, Insulation
YellowFibrous
Heterogeneous
95% Glass 5% Other None Detected
12-A / 19006538-034Operations Interior-Fiberglass Pipe Insulation Mastic, Mastic
WhiteNon-Fibrous
Heterogeneous
100% Other None Detected
12-B / 19006538-035Operations Interior-Fiberglass Pipe Insulation Mastic, Insulation
YellowFibrous
Heterogeneous
95% Glass 5% Other None Detected
12-B / 19006538-035Operations Interior-Fiberglass Pipe Insulation Mastic, Mastic
WhiteNon-Fibrous
Heterogeneous
100% Other None Detected
12-C / 19006538-036Operations Interior-Fiberglass Pipe Insulation Mastic, Insulation
YellowFibrous
Heterogeneous
95% Glass 5% Other None Detected
12-C / 19006538-036Operations Interior-Fiberglass Pipe Insulation Mastic, Mastic
WhiteNon-Fibrous
Heterogeneous
100% Other None Detected
13-A / 19006538-037Maintenance Roof Capstones-L. Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
13-B / 19006538-038Maintenance Roof Capstones-L. Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 7 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
13-C / 19006538-039Maintenance Roof Capstones-L. Caulk
GrayNon-Fibrous
Heterogeneous
100% Other None Detected
14-A / 19006538-040Maintenance Roof-Caulk
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
14-B / 19006538-041Maintenance Roof-Caulk
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
14-C / 19006538-042Maintenance Roof-Caulk
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
15-A / 19006538-043Maintenance Roof-Roofing System, Roofing
BlackNon-Fibrous
Heterogeneous
40% Cellulose 60% Other None Detected
15-A / 19006538-043Maintenance Roof-Roofing System, Felt Paper
BlackFibrous
Heterogeneous
75% Cellulose 25% Other None Detected
15-A / 19006538-043Maintenance Roof-Roofing System, Membrane
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
15-A / 19006538-043Maintenance Roof-Roofing System, Foam
YellowNon-Fibrous
Heterogeneous
100% Other None Detected
15-B / 19006538-044Maintenance Roof-Roofing System, Roofing
BlackNon-Fibrous
Heterogeneous
40% Cellulose 60% Other None Detected
15-B / 19006538-044Maintenance Roof-Roofing System, Felt Paper
BlackFibrous
Heterogeneous
75% Cellulose 25% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 8 of 12
Analyst: Vaughan, Nathaniel
Asbestos Bulk PLM EPA 600/R-93/116Stereoscopic Components
SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers
15-B / 19006538-044Maintenance Roof-Roofing System, Membrane
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
15-B / 19006538-044Maintenance Roof-Roofing System, Foam
YellowNon-Fibrous
Heterogeneous
100% Other None Detected
15-C / 19006538-045Maintenance Roof-Roofing System, Roofing
BlackNon-Fibrous
Heterogeneous
40% Cellulose 60% Other None Detected
15-C / 19006538-045Maintenance Roof-Roofing System, Felt Paper
BlackFibrous
Heterogeneous
75% Cellulose 25% Other None Detected
15-C / 19006538-045Maintenance Roof-Roofing System, Membrane
BlackNon-Fibrous
Heterogeneous
100% Other None Detected
15-C / 19006538-045Maintenance Roof-Roofing System, Foam
YellowNon-Fibrous
Heterogeneous
100% Other None Detected
Analyst:
Analysis Date: 2/20/2019 Date: 2/20/2019
Approved Signatory:
1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | [email protected]
07-19-0037Project Number:P.O. Number:
Project Name: Winchester WTP
2/12/2019Collected Date:
2/13/2019 10:15:00 AMReceived Date:
2/20/2019 6:28:52 PM
19006538SanAir ID Number
FINAL REPORT
Triad Engineering, Inc.Name:Address: 1097 Chaplin Road
Morgantown, WV 26501
3017976400Phone:
Page 9 of 12
Disclaimer
The final report cannot be reproduced, except in full, without written authorization from SanAir. Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Samples are held for a period of 60 days. For NY state samples, method EPA 600/M4-82-020 is performed. Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing. Asbestos Certifications NVLAP lab code 200870 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075 New York ELAP lab ID: 11983 Rhode Island License Number: AAL-126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000566 Vermont License: AL166318
Revision Date: 11/30/2017
Page 10 of 12
DMY LBP SURVEY REPORT
4400acArthur Boulevard, Suite 304, Washington, DC 20007 • www.dmycapitol.com • Phone: (202) 741-9159 GEOTECHNICAL ● ENVIRONMENTAL ● DRILLING ● INSTRUMENTATION ● MATERIALS TESTING
SPECIAL INSPECTIONS ● THIRD PARTY INSPECTIONS ● FACILITIES
PERCY D. MILLER WATER TREATMENT PLANT
32 PENCE LANE ROAD
MIDDLETOWN, VIRGINIA 22645
DMY PROJECT NO. 02.03044.01
Submitted to:
TRIAD ENGINEERING, INC. Attn: Mr. Jeffrey H. Mitchell, CPG
200 Aviation DriveWinchester, Virginia 22602
Submitted by:
DMY CAPITOL LLC 4400 MacArthur Boulevard, Suite 304
Washington, District of Columbia 20007
Inspector ____________________________________________ Brandon J. Colunga
Senior Environmental Project Manager
February 24, 2019
4400acArthur Boulevard, Suite 304, Washington, DC 20007 • www.dmycapitol.com • Phone: (202) 741-9159 GEOTECHNICAL ● ENVIRONMENTAL ● DRILLING ● INSTRUMENTATION ● MATERIALS TESTING
SPECIAL INSPECTIONS ● THIRD PARTY INSPECTIONS ● FACILITIES
LEAD-BASED PAINT SURVEY REPORT
On February 12, 2019, DMY Capitol LLC (DMY) conducted a Limited-Scope Lead-Based Paint Survey in the filter basin area in the interior of the operations structure and the roofs of the operations and maintenance structures located at 32 Pence Lane Road in Middletown,Virginia at the request of Mr. Jeffrey H. Mitchell, representing Triad Engineering, Inc. The scope of work for the Survey included an lead-based paint (LBP) analysis of only the areas identified for a pending renovation.
DMY conducted the LBP survey in the structure utilizing an X-ray fluorescence (XRF) unit in general accordance with the procedures and directives described in the U.S. Department of Housing and Urban Development (HUD) guidance document Guidelines for the Evaluation and
Control of Lead-Based Paint Hazards, June 1997. Because removal or management of any identified LBP or surface coatings is considered to be incidental to the renovation project and not intended as a lead abatement activity or to reduce or eliminate a lead-based paint hazard, testing for LBPs was conducted in a survey fashion and representative testing combinations were selected accordingly throughout the structure.
The survey consisted of testing the lead concentrations of painted surfaces using a Innov-X 6000 Alpha Series XRF analyzer. Typical tested surfaces included, but were not necessarily limited to, walls, interior and exterior door components, interior and exterior window components, and casework. Several building components were greater than 1.0 milligrams of lead per square centimeter (mg/cm2) and other building components exhibited detectable concentrations of lead that were below the 1.0 mg/cm2 threshold. With respect to the naming convention of walls within the structure, the “A” Wall refers to the side of the structure facing the addressed street, which in this case is the northwestern face of the site structure. The “B”, “C”,
and “D” Walls are subsequently named in a clockwise fashion. Additionally, in the case of structures such as doors or windows, the individual structures are denoted with sequential numerical subscripts in a clockwise fashion along a given wall. The following table includes all of the analyzed surfaces and those surfaces identified as containing greater than 1.0 mg/cm2 are denoted with bold text.
Room Name Side Structure Component Condition Substrate Color Lead
(mg/cm3)
Filter Operating
Floor A Wall - Intact Porcelain Cream 2.87
Filter Operating
Floor A Stairs Newel Post Intact Metal Blue >5.00
Filter Operating Floor A Stairs Handrail Intact Metal Yellow 0.02 Filter Operating
Floor B Wall - Intact Porcelain Cream 1.86
Filter Operating Floor B Ceiling Beam Intact Concrete Cream 0 Filter Operating Floor B Ceiling - Intact Concrete Cream 0
Filter Operating Floor B Floor Pedastal Intact Concrete Light Blue 0
Filter Operating
Floor B Wall Guard Rail Intact Metal Blue 5
Filter Operating D Wall I-Beam Column Intact Metal Orange 5
February 24, 2019 DMY Project No. 02.03044.01
Limited-Scope LBP Survey Report Percy D. Miller Water Treatment PlantMiddletown, Virginia Page 2
Room Name Side Structure Component Condition Substrate Color Lead
(mg/cm3)
Floor
Filter Operating Floor D Ceiling Beam Intact Concrete Cream 0 Filter Operating Floor D Ceiling Conduit Intact Metal Cream 0
Filter Operating Floor D Wall Controls - Filter #4 Intact Metal Gray-
Green 0
Filter Operating Floor D Wall Fan Bracket Intact Metal Brown 0.01 Filter Operating Floor D Wall Fan Intact Metal Tan 0 Filter Operating Floor D Wall Fan Intact Metal Brown 0
Rear Entrance Lobby A Wall - Intact Porcelain Cream 3.23
Rear Entrance Lobby A Wall Pipe Intact Cast Iron Black 0.4 Rear Entrance Lobby A Ceiling Beam Intact Concrete Cream 0 Rear Entrance Lobby A Ceiling - Intact Concrete Cream 0
Rear Entrance Lobby B Wall Master Filter Alarm Panel #3 Intact Metal Gray-
Green 0
Rear Entrance Lobby D Stairs Newel Post Intact Metal Blue 5 Rear Entrance Lobby D Stairs Handrail Intact Metal Yellow 0.17
Exterior B Wall Access Door Intact Metal Red 1.44
RECOMMENDATIONS
Based on the results of Limited-Scope LBP Survey at the site, DMY recommends the following:
LBP Survey – The planned renovations will not be designed as or intended to constitutea lead abatement activity or to reduce or eliminate a lead-based paint hazard. However,care should be taken during any renovation activity that will involve removal ordisturbance of LBP or lead-containing surface coatings to prevent contamination of thework area or adjacent spaces by lead dust or debris. Furthermore, any renovation workduring which employees may be occupationally exposed to lead must be conducted inaccordance with OSHA lead-safe work practices as set forth in 40 CFR 1926.62. Thisincludes any disturbance of LBP or any lead-containing surface coating.
The following items were identified or should be assumed to have a LBP coated surface: o All cream porcelain tiles within the Filter Operating Floor and Rear Entrance Lobby,o All blue paint located on the stair systems and guard rails,o The orange paint located on the I-beams within the columns of the Filter Operating
Floor, ando The red access doors located on the exterior of the Operations Building.
DMY made a reasonable effort to locate and sample all potential LBP associated with the pending renovation during the field survey as indicated by the field contact, Mr. Farrell Owens, the Facility Manager. However, DMY stresses that the LBP Survey was inherently limited to those conditions readily accessible to the DMY team during the field surveys. Conditions inside enclosed walls, pipe chases, or other inaccessible areas inside the site structure or historical conditions not previously divulged to DMY may not have been identified or otherwise assessed during this survey. DMY makes no other warranty, either expressed or implied, as to the
February 24, 2019 DMY Project No. 02.03044.01
Limited-Scope LBP Survey Report Percy D. Miller Water Treatment Plant Middletown, Virginia Page 3
professional services described herein. This report has been prepared by DMY for the use of the Triad Engineering, Inc. If you should have any questions or require further assistance, please contact the undersigned.
LIMITATIONS
It was attempted to perform a Limited-Scope LBP Survey of the structure located at 32 Pence Lane Road; however, some areas may have been hidden or impracticable to access. These areas may include, but are not necessarily limited to, the sub-grade; above or behind ceilings and walls; and pipe and utility chases.
The demolition and/or abatement contractor has the responsibility for determining actual quantities of all materials.
USE OF REPORT
This report has been prepared for the exclusive use of the Client and persons or organizations to which the Client wishes to make this report available. This report and the findings and recommendations contained herein shall not, in whole or in part, be used by or relied upon by any other party, without the prior written consent of DMY.
We appreciate the opportunity to assist you with this project. If you have any questions or require further assistance, please do not hesitate to contact the undersigned.
Sincerely, DMY Capitol, LLC
Brandon J. Colunga Senior Project Environmental Scientist
PHOTOGRAPHS
PROJECT NO. 07-19-0037 Page 1 of 4
DATE: February 12, 2019
CLIENT: Painter-Lewis, P.L.C. PROJECT NAME: Percy D. Miller Water Treatment Plant – Operations & Maintenance Building Renovations - ACM & LBP Survey 32 Pence Lane Road Middletown, Virginia 22645
Photograph # 1
View of a Sample 10-A Operations Upper Roof – Gray Caulk sampling location, which according to the asbestos laboratory, is underlain by black caulk that contains 3% Chrysotile Asbestos and is therefore
asbestos-containing material (ACM).
Photograph # 2
View of the porcelain tile that contain a lead-based coated surface.
PROJECT NO. 07-19-0037 Page 2 of 4
DATE: February 12, 2019
CLIENT: Painter-Lewis, P.L.C. PROJECT NAME: Percy D. Miller Water Treatment Plant – Operations & Maintenance Building Renovations - ACM & LBP Survey 32 Pence Lane Road Middletown, Virginia 22645
Photograph # 3
View of the porcelain tile that contain a lead-based coated surface.
Photograph # 4
View of the blue guard rails that contain a lead-based paint (LBP) surface.
PROJECT NO. 07-19-0037 Page 3 of 4
DATE: February 12, 2019
CLIENT: Painter-Lewis, P.L.C. PROJECT NAME: Percy D. Miller Water Treatment Plant – Operations & Maintenance Building Renovations - ACM & LBP Survey 32 Pence Lane Road Middletown, Virginia 22645
Photograph # 5
View of the blue guard rails that contain a LBP surface.
Photograph # 6
View of the orange steel I-beam column that contains a LBP surface.
PROJECT NO. 07-19-0037 Page 4 of 4
DATE: February 12, 2019
CLIENT: Painter-Lewis, P.L.C. PROJECT NAME: Percy D. Miller Water Treatment Plant – Operations & Maintenance Building Renovations - ACM & LBP Survey 32 Pence Lane Road Middletown, Virginia 22645
Photograph # 7
View of the red access door that contains a LBP surface.