1
Pond Pond BUS STOP BUS STOP invt invt 562 561 585 585 586 586 587 587 588 588 589 589 590 590 591 591 592 592 593 593 shed shed 587 586 585 8 BCP BCP > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > 225Ø 150Ø 225Ø 150Ø 150Ø 225Ø 300Ø > > > IL 97.70 IL 96.70 IL 95.80 98.80 X I C P 600Ø 1 Conc I S C Pipe 1.009 600Ø 1:129 / Concr IL 94.60 F7 (1200Ø) CL 97.55 IL 94.15 F8 (1200Ø) CL 97.29 Pipe 1.006 150Ø 1:50 / 22.7m Clay IL 92.55 F10 (1200Ø) CL 96.96 Pipe 1.007 150Ø 1:17 / 27.0m Clay I F C Pipe 1.008 225Ø 1:109 / 20.2m Clay Pipe 1.009 225Ø 1:148 / 50.2m Clay Pipe N2 1.000 225Ø 1:81 / 49.7m Clay Headwall 2 IL 94.250 (825Ø) IL S C Pipe 1.007 600Ø 1:157 / 20.4m Concrete Pipe 1.008 600Ø 1:160 / 27.2m Concrete 825Ø 1:352 Pip 150Ø 1:5 Clay 96.88 IL 96.500 x Lat SW7 (1200Ø CL 97.850 IL 96.300 x Lat SW8 (1200Ø) CL 97.650 150Ø 1:11 IL 96.002 x Lat SW9a (1200Ø) CL 97.399 150Ø 1:13 IL 95.700 x Lat SW10 (1200Ø) CL 97.079 150Ø 1:14 IL 95.300 x Lat SW11 (1200Ø) CL 96.796 150Ø 1:98 IL 96.40 x Lat FW CL 97.8 IL 96.100 x Lat FW7 (1200Ø) CL 97.667 150Ø 1:5 IL 95.500 x Lat FW10a (1200Ø) CL 97.101 150Ø 1:2 IL 95.428 x Lat FW11 (1200Ø) CL 96.834 150Ø 1:2 I S C 150Ø 1:47 150Ø 1:10 150Ø 1:11 Road 1 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 110.0 120.0 130.0 140.0 150.0 160.0 170.0 180.0 0m F33 IL: 95.60m F35 IL: 95.50m F37 CL: 98.759m IL: 95.30m F39 IL: 94.90m F41 IL: 94.450m F43 IL: 94.325m Existing CL: 96.839m IL: 93.953m S32 IL: 98.725m HW1 IL: 98.50m S36 IL: 98.20m HW2 IL: 97.50m HW3 IL: 96.00m S76 IL: 96.665m S78 IL: 96.15m S82 IL: 96.65m S84 IL: 96.575m S86 IL: 96.425m S88 IL: 96.20m 150Ø 1/118 11.767m 1.016 450Ø 1/221 22.137m 5.006 150Ø 1/117 23.343m 1.015 225Ø 1/276 20.713m 7.001 225Ø 1/158 11.840m 7.000 150Ø 1/38 14.247m 1.021 150Ø 1/110 13.727m 1.020 450Ø 1/154 23.038m 5.008 450Ø 1/249 12.428m 7.003 600Ø 1/20 6.118m 1.016 600Ø 1/6 4.283m 1.017 5 150Ø 1/120 54.002m 1.019 300Ø 1/230 17.241m 7.002 150Ø 1/114 45.512m 1.018 150Ø 1/107 21.477m 1.017 450Ø 1/52 21.592m 5.007 OF1 OF2 IL: 98.518m OF3 IL: 98.325m 300Ø 1/140 28.958m Overflow Pipe 2 300Ø 1/140 26.674m Overflow Pipe 3 300Ø 1/122 15.303m Overflow Pipe 3 Ex. Pond 98.5m Bed Level 300mm Freeboard 99.900m Top of Bank S200 IL: 95.597m S202 IL: 95.468m Existing CL: 96.856m IL: 95.30m 225Ø 1/100 12.932m 9.000 225Ø 1/100 16.841m 9.001 00.300 FFL 100.750 FFL 101.200 FFL 101.350 FFL 101.500 FFL GARAGE 101.350 GARAGE 101.050 96.301 96.364 96.614 96.864 97.114 97.137 97.364 97.614 97.861 98.061 98.170 98.201 98.326 98.389 98.451 98.501 98.575 98.638 98.700 98.779 98.826 98.953 98.990 99.077 99.160 99.198 99.323 96.296 96.296 96.300 96.363 96.613 96.863 97.113 97.136 97.363 97.613 97.860 98.060 98.169 98.200 98.325 98.388 98.449 98.499 98.574 98.637 98.698 98.776 98.823 98.948 98.981 99.073 99.159 99.198 99.323 99.387 Note - Existing Drainage Connection Details TBC & altered accordingly to suit the Proposed invt invt w.l. w.l. w.l. post 98.41 98.60 98.51 98.45 98.46 98.52 98.76 99.27 99.43 99.50 99.56 99.96 100.08 101.45 100.08 99.95 100.29 17 99.79 99.51 98.98 98.78 1 97.80 97.71 97.74 95.94 95.71 96.13 96.55 96.71 96.90 97.17 97.48 98.02 98.76 98.39 98.44 98.62 98.55 98.54 98.48 98.28 98.49 98.53 98.24 98.41 98.17 97.98 97.77 97.56 97.67 97.61 97.70 97.77 97.89 98.13 98.25 98.23 98.52 98.33 98.07 97.84 97.69 97.64 97.49 97.35 97.19 9 96.32 96.66 96.85 97.05 97.20 97.35 97.49 97.45 97.60 97.93 98.31 98.51 98.16 97.79 97.52 97.32 97.00 96.69 96.65 96.79 96.34 96.17 9 96.54 96.50 96.17 96.50 97.02 97.72 98.17 98.51 99.17 100.12 99.18 98.63 98.22 97.64 97.17 96.91 97.26 97.48 97.61 97.98 98.42 99.03 99.59 100.27 99.75 99.41 99.28 98.72 98.88 98.23 98.28 97.93 98.17 98.27 98.60 98.61 99.71 99.63 99.40 99.19 99.68 99.90 100.15 100.35 100.38 99.25 99.13 100.70 100.25 98.79 98.43 98.28 98.18 97.77 97.47 97.27 97.00 96.01 96.31 97.57 97.43 97.31 96.87 96.84 96.64 96.28 96.01 96.59 96.92 97.09 97.35 98.60 98.87 99.03 98.25 97.27 97.67 97.81 97.55 97.53 98.28 97.43 97.99 98.23 98.44 98.49 98.44 98.72 98.72 98.78 98.63 98.46 98.70 99.06 98.10 96.26 98.51 97.61 98.70 98.78 98.42 99.90 97.47 99.16 99.22 99.29 99.23 99.40 98.85 99.76 100.40 97.51 97.01 97.23 95.86 97.48 95.44 Pond 96 0 100 98 98 98 98 98 98 98 98 100 8 98 LEVEL OF EXISTING ROAD AT POINT OF TIE IN WITH PROPOSED SITE ROAD MUST BE CHECKED BEFORE COMMENCEMENT OF WORKS AND ANY DISCREPANCIES REPORTED IMMEDIATELY. FOUNDATIONS FOR PLOTS ADJACENT TO ADOPTABLE SEWERS LESS THAN 5m AWAY FROM PLOT WALL TO BE LOWER THAN THE INVERT LEVELS OF SEWER TO PREVENT ANY LOADING FORCES ON THE PIPEWORK POLISHED STONE VALUES, AGGREGATE SIZES, AGGREGATE ABRASION VALUES AND PENETRATION VALUES OF ALL SURFACE COURSE MATERIALS MUST BE CHECKED WITH HIGHWAY AUTHORITY AND COMPLY WITH ALL CODES OF PRACTICE PRIOR TO ORDERING AND LAYING OF MATERIALS ALL ADOPTABLE DRAINAGE MUST COMPLY WITH SEWERS FOR ADOPTION 6TH EDITION AND ADOPTING WATER AUTHORITIES REQUIREMENTS S106 APPLICATION A SECTION 106 APPLICATION TO SEVERN TRENT WATER MUST BE COMPLETED FOR THE RE USE OF ANY EXISTING CONNECTION INTO THE EXISTING PUBLIC SEWERAGE SYSTEM OR THE CONSTRUCTION OF A NEW CONNECTION. AN APPLICATION WILL BE REQUIRED FOR THE FOUL AND SURFACE WATER DRAINAGE ARRANGEMENTS AND THIS SHOULD BE COMPLETED BY THE CONTRACTOR. MANHOLE RINGS SHALL NOT BE CUT A SCREEN AND SUMP IS TO BE FITTED OVER THE OUTGOING PIPE TO THE LAST NEW SURFACE AND FOUL MANHOLES BEFORE ENTERING THE EXISTING SEWERS IN ACCORDANCE WITH SEWERS FOR ADOPTION 6. THE SCREEN SHALL ONLY BE REMOVED ONCE ON SITE CONSTRUCTION WORKS HAVE BEEN COMPLETED SURFACE WATER SEWER NETWORK DESIGNED IN ACCORDANCE WITH ROADS IDENTIFIED ON ORIGINAL DRAINAGE AND LEVELS CONCEPT LAYOUT AND POSITIONS ARE SUBJECT TO CHANGE ALL EXISTING SEWER LEVELS AND LOCATIONS TO BE CHECKED AND VERIFIED PRIOR TO ANY CONSTRUCTION WORKS AND ANY DISCREPANCIES REPORTED IMMEDIATELY. MATERIALS FOR ADOPTABLE SEWERS PIPES 150mm - 300mm DIA :- SURFACE AND FOUL WATER PIPES ARE TO BE EXTRA STRENGTH VITRIFIED CLAY WITH FLEXIBLE MECHANICAL JOINTS. PIPES MUST COMPLY WITH THE RELEVANT REQUIREMENTS OF BS EN 295-1:2013 AND BS 65:1991 (surface water pipes only). PIPES > 300mm:- DIA SURFACE AND FOUL WATER PIPES ARE TO BE HIGH STRENGTH CONCRETE. CONCRETE PIPES AND FITTINGS WITH FLEXIBLE JOINTS SHALL COMPLY WITH THE RELEVANT PROVISIONS OF BS 5911-1:2002. SURFACE WATER MANHOLE S36 IS TO BE FITTED WITH A HYDROBRAKE. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT DESIGN DRAWINGS AND OTHER INFORMATION ANY POND BED LINING AND / OR BANK STABILISATION METHODS REQUIRED FOR BALANCING POND TO BE ASSESSED BY STRUCTURAL ENGINEER IMPORTANT: HEADWALLS WILL REQUIRE THE ENVIRONMENT AGENCY'S PRIOR WRITTEN CONSENT UNDER SECTION 109 OF THE WATER RESOURCES ACT 1991 BEFORE ANY CONSTRUCTION TAKES PLACE HEADWALLS TO BE PRE_CAST CONCRETE. PIPES OF DIFFERENT DIAMETERS ENTERING MANHOLES SHOULD BE INSTALLED WITH SOFFITS AT THE SAME LEVEL THE OUTSIDE OF THE SEWER SHOULD BE IN VEHICLE CARRIAGEWAY (NOT FOOTPATH) AND BE AT LEAST 1m FROM KERB LINE. THE OUTSIDE MANHOLES SHOULD BE AT LEAST 0.5m FROM THE KERB LINE. TREES ON THE DRAWING ARE EXISTING OR PROPOSED AND ADHERE TO B.2.3 (PAGE 33) OF SFA6. THE TREES SPECIFIED WILL BE AS PER SEWERS FOR ADOPTION AND POSITIONED. WHERE CLEARANCES WITH VEGETATION IS NOT ACHIEVABLE, APPROPRIATE ROOT PROTECTION WILL BE PROVIDED THE MATERIALS TO BE USED ARE SUITABLE FOR THE GROUND CONDITIONS WHERE PIPE CROSSING, PLASTIC MEMBRANE TO BE USED FOR PROTECTION TO ELIMINATE CHANCES OF CROSS CONTAMINATION PRELIMINARY SUBJECT TO SECTION 38 & 104 APPROVAL 2 7 Notes: 1) Larger sizes may be required for manholes on bends or where there are junctions. 2) May be reduced to 675 by 675 where required by highway loading considerations, subject to a safe system of work being specified. 3) Not applicable due to working space needed. 4) Minimum height of chamber in shafted manhole 2m from benching to underside of reducing slab. 5) Min clear space between ladders or steps and the opposite face of the shaft should be approximately 900mm. 6) Winch only - no steps or ladders, permanent or removable 7) The minimum size of any manhole serving a sewer (i.e any drain serving more than one property) should be 1200 mm x 675 mm rectangular or 1200 mm diameter 600 600 600 na³ Circular diameter 675 x 675 675 x 675 675 x 675 1050 1200 900 1050 x 800 1200 x 800 900 x 800 6 5 5 Steps Ladder Winch 1200 1200 1200 The larger of 1800 or (DN+775) 1000 1200 1200 The larger of 1800 or (DN+450) Circular diameter 4 Min clear opening size¹ Rectangular length and width 2 750 x 675 1200 x 675 7 Manhole shaft > 3.0m deep to soffit of pipe 1200 x 1000 1200 x 1075 1350 x 1225 1800 x (DN+775) 750 x 675 1200 x 675 1200 x 750 1800 x (DN+450) Min internal dimensions¹ Rectangular length and width ≤ 225 300 375-450 >450 ≤ 150 225 300 >300 Size of largest pipe (DN) Manhole < 1.5m deep to soffit > 1.5m deep to soffit Type Minimum Dimensions for Manholes Severn Trent Water Manhole Requirements For Sewers For Adoption 6th Edition - Adoptions & Diversions General requirements Copies of delivery notes for concrete and pipe bedding will be required intermittently as the job progresses. All other component units must be kite-marked. Channels and Benching All chambers with pipe sizes 150mm, 225mm, 300mm must have swept bends and channels. All benching to be a minimum 40mm thick granolithic concrete trowelled to a smooth finish. Ironwork In Manholes If the chamber is less than 3m deep we require double encapsulated step rungs unless otherwise approved. If the chamber is over 3m deep we require hot dipped galvanised mild steel ladders. There must be 900mm between ladder and back of shaft. Depth is measured from finished cover level to the top of the benching. The maximum distance between cover level and the first step must be 675mm. Brickwork Min 2 max 4 courses under frame and must be solid class B engineering bricks or concrete spacing rings neatly pointed up. English Bond to be used on all brickwork. Sulphate resisting cement must be used in all locations. Cover and Frames Cover slab opening, cover and frames must be 675 x 675 unless otherwise approved. DN400 shall be used at all locations. On spine roads must be 150mm deep. On residential cul-de-sacs 100mm may be used subject to approval. Frames for manhole covers should be bedded in a polyester resin bedding mortar in all situations where covers are sited in NRSWA Road Categories I, II or III. 'Infill' type covers should not be used. In block paved areas 150mm deep frames must be used (in accordance with cl 2.8.6 SfA6 p.25) Laterals They should be laid to the same standard as public sewers. They should have no changes of line or gradient between the sewer and the demarcation chamber. They should have an adoptable manhole as the demarcation chamber unless there is only on property when a plastic chamber to BS EN 13598-2:2009 is allowed. Lockable B125 and A15 covers may be allowed in certain locations subject to approval. The demarcation should be inside the boundary of the property, no more than 1m inside the boundary, preferably in the driveway and not in the wheel tracks of vehicles. FOUL WATER Manhole Pipe line Direction Arrow Rising Main Demarcation Chamber* SURFACE WATER Manhole Pipe line Direction Arrow Demarcation Chamber* HIGHWAY DRAINAGE Manhole Gully Highway Drain / Gully Connection OTHER Existing Sewers to be abandoned/ grubbed up in accordance with Severn Trent Water Specification * Demarcation chambers to be constructed as per adoptable manhole construction details depending on chamber depth. A 450Ø Inspection chamber can be used providing lateral only serves one plot. XXXX Client Title Status Date Created Scale @ A0 PM/Checked by Drawn By Drawing Number Rev Project Job Ref rpsgroup.com/uk c 2018 RPS Group Notes 1. This drawing has been prepared in accordance with the scope of RPS’s appointment with its client and is subject to the terms and conditions of that appointment. RPS accepts no liability for any use of this document other than by its client and only for the purposes for which it was prepared and provided. 2. If received electronically it is the recipients responsibility to print to correct scale. Only written dimensions should be used. MAKING COMPLEX EASY Salisbury House, 2A Tettenhall Road, Wolverhampton, West Midlands, WV1 4SA T: 01902 925500 E: [email protected] Preliminary AG AAC5560 NJEJ 1:200 04.03.20 900-3 P01 St. Modwen Homes Phase 2B Uttoxeter Engineering Layout Sheet 2 Rev Description Date Initial Checked P01 Latest Layout added, slight amendments made to drainage. 20.03.20 NJEJ AG For guidance only. Do not scale off this drawing 1:20 - 5m 4m 400mm 3m 300mm 2m 200mm 1m 100mm 0 0 2000 1800 1600 1400 1200 800mm 600mm 400mm 200mm 0 9m 10m 0 1m 2m 3m 4m 5m 6m 7m 8m 1000 1:100- 1:50 - 1:5 - 500mm P/2020/00671 Received 02/07/2020

AAC5560 RPS XX XX DR C 900-3 Engineering Layout - Sheet 2 P01

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AAC5560 RPS XX XX DR C 900-3 Engineering Layout - Sheet 2 P01

PondPond

BU

S

ST

OP

BU

S

ST

OP

invtinvt

562

561

585

585

586

586

587

587

588

588

589

589

590

590

591

591

592

592

593

593

s

h

e

d

s

h

e

d

587

586

585

588

BCP

BCP

>

>>

>

>>

>

>>

>

>>

>

>>

>>

>>

>

>

>>

>

>

>>

>

>>

>>

>>

>>

>

>>

>>

>>

>>

>>

> > > > > > > > > >>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>>

>

>

>

>

225Ø

150Ø

225Ø

150Ø150Ø

225Ø

300Ø

>

>

>IL 97.70

IL 96.70

IL 95.80

98.80 XIL 94.99

S8 (1500Ø)CL 97.56

Pipe 1.006

600Ø 1:33 / 12.0m

Concrete

IL 94.69

S10 (1500Ø)CL 96.95

Pipe 1.009

600Ø 1:129 / 1

1.6m

Concrete

IL 94.60

F7 (1200Ø)CL 97.55

IL 94.15

F8 (1200Ø)CL 97.29

Pipe

1.0

06

150Ø

1:5

0 /

22.7

m

Clay

IL 92.55

F10 (1200Ø)CL 96.96

Pipe

1.0

0715

0Ø 1

:17

/ 27

.0m

Clay

IL 92.36

F11 (1200Ø)CL 96.72

Pipe

1.0

0822

5Ø 1

:109

/ 2

0.2m

Clay

Pipe

1.0

0922

5Ø 1

:148

/ 5

0.2m

Clay

Pipe

N2

1.00

022

5Ø 1

:81

/ 49

.7m

Clay

Headwall 2IL 94.250 (825Ø)

IL 94.86

S9 (1500Ø)CL 97.29

Pipe

1.0

07

600Ø

1:1

57 /

20.

4mCo

ncre

tePi

pe 1

.008

600Ø

1:1

60 /

27.

2mCo

ncre

te

825Ø 1:352

Pipe 1.005

150Ø 1:55 / 13.8m

Clay

96.88

IL 96.500

x Lat SW7 (1200Ø)CL 97.850

IL 96.300

x Lat SW8 (1200Ø)CL 97.650

150Ø 1:11

IL 96.002

x Lat SW9a (1200Ø)CL 97.399 150Ø 1:13

IL 95.700

x Lat SW10 (1200Ø)CL 97.079

150Ø 1:14

IL 95.300

x Lat SW11 (1200Ø)CL 96.796

150Ø 1:98

IL 96.400

x Lat FW6 (1200Ø)CL 97.875

IL 96.100

x Lat FW7 (1200Ø)CL 97.667

150Ø 1:5

IL 95.500

x Lat FW10a (1200Ø)CL 97.101

150Ø 1:2

IL 95.428

x Lat FW11 (1200Ø)CL 96.834

150Ø 1:2

IL 95.12

S11 (1200Ø)CL 96.71

150Ø 1:47

150Ø 1:10150Ø 1:11

Road 1

0.0

10.0

20.0

3

0

.0

4

0

.0

5

0

.0

6

0

.0

7

0

.0

8

0

.0

9

0

.0

100.0

110.0

120.0

1

3

0

.0

1

4

0

.

0

1

5

0

.0

160.0

1

7

0

.

0

1

8

0

.

0

IL: 95.80m

F33

IL: 95.60mF35

IL: 95.50m

F37

CL: 98.759m

IL: 95.30m

F39

IL: 94.90m

F41

IL: 94.450m

F43

IL: 94.325m

Existing

CL: 96.839m

IL: 93.953m

S32

IL: 98.725m

HW1

IL: 98.50m

S36

IL: 98.20m

HW2

IL: 97.50m

HW3

IL: 96.00m

S76

IL: 96.665m

S78

IL: 96.15m

S82

IL: 96.65m

S84

IL: 96.575m

S86

IL: 96.425m

S88

IL: 96.20m

150Ø

1/1

18

11.7

67m

1.0

16

4

5

0

Ø

1

/

2

2

1

2

2

.

1

3

7

m

5

.

0

0

6

1

5

0

Ø

1

/

1

1

7

2

3

.

3

4

3

m

1

.

0

1

5

225Ø

1/2

76

20.7

13m

7.0

01

2

2

5

Ø

1

/1

5

8

1

1

.8

4

0

m

7

.0

0

0

150Ø 1/38

14.247m 1.021

150Ø

1/110

13.727m

1.020

4

5

0

Ø

1

/1

5

4

2

3

.0

3

8

m

5

.0

0

8

450Ø

1/249

12.428m

7.003

600Ø 1/20

6.118m 1.016

600Ø 1/6

4.283m 1.017

5.900m

1.014

1

5

0

Ø

1

/1

2

0

5

4

.0

0

2

m

1

.0

1

9

3

0

0

Ø

1

/2

3

0

1

7

.2

4

1

m

7

.0

0

2

150Ø

1/1

14

45.5

12m

1.0

18

1

5

0

Ø

1

/1

0

7

2

1

.4

7

7

m

1

.0

1

7

450Ø

1/52

21.592m

5.007

OF1

OF2

IL: 98.518m

OF3

IL: 98.325m

3

0

0

Ø

1

/1

4

0

2

8

.9

5

8

m

O

v

e

rflo

w

P

ip

e

2

3

0

0

Ø

1

/1

4

0

2

6

.6

7

4

m

O

v

e

rflo

w

P

ip

e

3

300Ø

1/1

22

15.3

03m

Overf

low

Pip

e 3

Ex. Pond

98.5m Bed Level

300mm Freeboard

99.900m Top of Bank

S200

IL: 95.597m

S202

IL: 95.468m

Existing

CL: 96.856m

IL: 95.30m

2

2

5

Ø

1

/1

0

0

1

2

.9

3

2

m

9

.0

0

0

225Ø

1/1

00

16.8

41m

9.0

01

100.300

FFL

100.750

FFL

101.200

FFL

101.350

FFL

101.500

FFL

G

A

R

A

G

E

1

0

1

.3

5

0

G

A

R

A

G

E

1

0

1

.0

5

0

96.301

96.364

96.6

14

9

6

.8

6

4

9

7

.1

1

4

9

7

.1

3

7

9

7

.3

6

4

9

7

.6

1

4

9

7

.8

6

1

9

8

.0

6

1

9

8

.1

7

0

9

8

.2

0

1

98.3

26

98.389

98.4

51

98.501

98.575

98.638

9

8

.7

0

0

9

8

.7

7

9

9

8

.8

2

6

9

8

.9

5

3

9

8

.9

9

0

99.077

9

9

.

1

6

0

9

9

.

1

9

8

9

9

.

3

2

3

96.296

96.296

96.300

96.363

96.6

13

9

6

.8

6

3

9

7

.1

1

3

9

7

.1

3

6

9

7

.3

6

3

9

7

.6

1

3

9

7

.8

6

0

9

8

.0

6

0

9

8

.1

6

9

9

8

.2

0

0

98.3

25

98.388

98.4

49

98.499

98.574

98.637

9

8

.6

9

8

9

8

.7

7

6

9

8

.8

2

3

9

8

.9

4

8

9

8

.9

8

1

99.073

9

9

.

1

5

9

9

9

.

1

9

8

9

9

.

3

2

3

9

9

.

3

8

7

Note - Existing

Drainage Connection

Details TBC & altered

accordingly to suit the

Proposed

invt

invt

w.l.

w.l.

w.l.

post

98.41

98.60

98.51

98.45

98.46

98.52

98.76

99.27

99.43

99.5099.56

99.96

100.08

101.45

100.08

99.95

100.29

100.17

99.79

99.51

98.98

98.78

99.11

97.80

97.71

97.74

95.94

95.71

96.1396.55

96.71

96.90

97.17

97.48

98.02

98.76

98.39

98.44

98.62

98.55

98.54

98.48

98.28

98.49

98.53

98.24

98.41

98.17

97.98

97.77

97.56

97.67

97.61

97.70

97.77

97.89

98.13

98.2598.23

98.52

98.33

98.07

97.84

97.69

97.64

97.49

97.35

97.19

96.00

96.32

96.66

96.85

97.05

97.20

97.35

97.49

97.45

97.60

97.93

98.31

98.51

98.16

97.79

97.52

97.32

97.00

96.69

96.65

96.79 96.3496.17 95.70

96.54

96.50

96.17

96.50

97.02

97.72

98.17

98.51

99.17

100.12

99.18

98.63

98.22

97.64

97.17

96.91

97.26

97.48

97.61

97.98

98.42

99.03

99.59

100.27

99.75

99.41

99.28

98.72

98.88

98.23

98.28

97.93

98.17

98.27

98.60

98.61

99.71

99.63

99.40

99.19

99.68

99.90

100.15

100.35

100.3899.25

99.13

100.70

100.25

98.79

98.43

98.28

98.18

97.77

97.47

97.27

97.00

96.01

96.31

97.57

97.43

97.31

96.87

96.84

96.64 96.28

96.01

96.59

96.92

97.09

97.35

98.60

98.87

99.03

98.25

97.27

97.67

97.81

97.55

97.5398.28

97.43

97.99

98.23

98.44

98.49

98.44

98.72

98.72

98.78

98.63

98.46

98.7099.06

98.10

96.26

98.51

97.61

98.70

98.78

98.42

99.90

97.47

99.16

99.22

99.29

99.23

99.40

98.85

99.76

100.40

97.51

97.01

97.23

95.86

97.48

95.44

Pond

96

100

100

98

98

98

98

98

98

98

98

100

98

98

LEVEL OF EXISTING ROAD AT POINT OF TIE IN WITH

PROPOSED SITE ROAD MUST BE CHECKED BEFORE

COMMENCEMENT OF WORKS AND ANY DISCREPANCIES

REPORTED IMMEDIATELY.

FOUNDATIONS FOR PLOTS ADJACENT TO ADOPTABLE

SEWERS LESS THAN 5m AWAY FROM PLOT WALL TO BE

LOWER THAN THE INVERT LEVELS OF SEWER TO PREVENT

ANY LOADING FORCES ON THE PIPEWORK

POLISHED STONE VALUES, AGGREGATE SIZES,

AGGREGATE ABRASION VALUES AND PENETRATION

VALUES OF ALL SURFACE COURSE MATERIALS MUST BE

CHECKED WITH HIGHWAY AUTHORITY AND COMPLY WITH

ALL CODES OF PRACTICE PRIOR TO ORDERING AND

LAYING OF MATERIALS

ALL ADOPTABLE DRAINAGE MUST COMPLY WITH SEWERS

FOR ADOPTION 6TH EDITION AND ADOPTING WATER

AUTHORITIES REQUIREMENTS

S106 APPLICATION

A SECTION 106 APPLICATION TO SEVERN TRENT WATER

MUST BE COMPLETED FOR THE RE USE OF ANY EXISTING

CONNECTION INTO THE EXISTING PUBLIC SEWERAGE

SYSTEM OR THE CONSTRUCTION OF A NEW CONNECTION.

AN APPLICATION WILL BE REQUIRED FOR THE FOUL AND

SURFACE WATER DRAINAGE ARRANGEMENTS AND THIS

SHOULD BE COMPLETED BY THE CONTRACTOR.

MANHOLE RINGS SHALL NOT BE CUT

A SCREEN AND SUMP IS TO BE FITTED OVER THE

OUTGOING PIPE TO THE LAST NEW SURFACE AND FOUL

MANHOLES BEFORE ENTERING THE EXISTING SEWERS IN

ACCORDANCE WITH SEWERS FOR ADOPTION 6.

THE SCREEN SHALL ONLY BE REMOVED ONCE ON SITE

CONSTRUCTION WORKS HAVE BEEN COMPLETED

SURFACE WATER SEWER NETWORK DESIGNED IN

ACCORDANCE WITH ROADS IDENTIFIED ON ORIGINAL

DRAINAGE AND LEVELS CONCEPT LAYOUT AND POSITIONS

ARE SUBJECT TO CHANGE

ALL EXISTING SEWER LEVELS AND LOCATIONS TO BE

CHECKED AND VERIFIED PRIOR TO ANY CONSTRUCTION

WORKS AND ANY DISCREPANCIES REPORTED

IMMEDIATELY.

MATERIALS FOR ADOPTABLE SEWERS

PIPES 150mm - 300mm DIA :-

SURFACE AND FOUL WATER PIPES ARE TO BE EXTRA

STRENGTH VITRIFIED CLAY WITH FLEXIBLE MECHANICAL

JOINTS. PIPES MUST COMPLY WITH THE RELEVANT

REQUIREMENTS OF BS EN 295-1:2013 AND BS 65:1991

(surface water pipes only).

PIPES > 300mm:-

DIA SURFACE AND FOUL WATER PIPES ARE TO BE HIGH

STRENGTH CONCRETE. CONCRETE PIPES AND FITTINGS

WITH FLEXIBLE JOINTS SHALL COMPLY WITH THE

RELEVANT PROVISIONS OF BS 5911-1:2002.

SURFACE WATER MANHOLE S36 IS TO BE FITTED WITH A

HYDROBRAKE.

THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL

RELEVANT DESIGN DRAWINGS AND OTHER INFORMATION

ANY POND BED LINING AND / OR BANK STABILISATION

METHODS REQUIRED FOR BALANCING POND TO BE

ASSESSED BY STRUCTURAL ENGINEER

IMPORTANT:

HEADWALLS WILL REQUIRE THE ENVIRONMENT AGENCY'S

PRIOR WRITTEN CONSENT UNDER SECTION 109 OF THE

WATER RESOURCES ACT 1991 BEFORE ANY

CONSTRUCTION TAKES PLACE

HEADWALLS TO BE PRE_CAST CONCRETE.

PIPES OF DIFFERENT DIAMETERS ENTERING MANHOLES

SHOULD BE INSTALLED WITH SOFFITS AT THE SAME LEVEL

THE OUTSIDE OF THE SEWER SHOULD BE IN VEHICLE

CARRIAGEWAY (NOT FOOTPATH) AND BE AT LEAST 1m

FROM KERB LINE. THE OUTSIDE MANHOLES SHOULD BE AT

LEAST 0.5m FROM THE KERB LINE.

TREES ON THE DRAWING ARE EXISTING OR PROPOSED

AND ADHERE TO B.2.3 (PAGE 33) OF SFA6. THE TREES

SPECIFIED WILL BE AS PER SEWERS FOR ADOPTION AND

POSITIONED. WHERE CLEARANCES WITH VEGETATION IS

NOT ACHIEVABLE, APPROPRIATE ROOT PROTECTION WILL

BE PROVIDED

THE MATERIALS TO BE USED ARE SUITABLE FOR THE

GROUND CONDITIONS

WHERE PIPE CROSSING, PLASTIC MEMBRANE TO BE USED

FOR PROTECTION TO ELIMINATE CHANCES OF CROSS

CONTAMINATION

PRELIMINARY

SUBJECT TO SECTION 38 & 104

APPROVAL

2

7

Notes:

1) Larger sizes may be required for manholes on bends or where there are junctions.

2) May be reduced to 675 by 675 where required by highway loading considerations, subject to a safe system of work being specified.

3) Not applicable due to working space needed.

4) Minimum height of chamber in shafted manhole 2m from benching to underside of reducing slab.

5) Min clear space between ladders or steps and the opposite face of the shaft should be approximately 900mm.

6) Winch only - no steps or ladders, permanent or removable

7) The minimum size of any manhole serving a sewer (i.e any drain serving more than one property) should be 1200 mm x 675 mm

rectangular or 1200 mm diameter

600

600

600

na³

Circular

diameter

675 x 675

675 x 675

675 x 675

1050

1200

900

1050 x 800

1200 x 800

900 x 800

6

5

5

Steps

Ladder

Winch

1200

1200

1200

The larger of 1800

or (DN+775)

1000

1200

1200

The larger of 1800

or (DN+450)

Circular

diameter

4

Min clear

opening size¹

Rectangular

length and width

2

750 x 675

1200 x 675

7

Manhole shaft

> 3.0m deep to

soffit of pipe

1200 x 1000

1200 x 1075

1350 x 1225

1800 x

(DN+775)

750 x 675

1200 x 675

1200 x 750

1800 x

(DN+450)

Min internal

dimensions¹

Rectangular

length and width

≤ 225

300

375-450

>450

≤ 150

225

300

>300

Size of largest

pipe (DN)

Manhole

< 1.5m deep to soffit

> 1.5m deep to soffit

Type

Minimum Dimensions for Manholes

Severn Trent Water Manhole Requirements For Sewers

For Adoption 6th Edition - Adoptions & Diversions

General requirements

Copies of delivery notes for concrete and pipe bedding will be required intermittently

as the job progresses. All other component units must be kite-marked.

Channels and Benching

All chambers with pipe sizes 150mm, 225mm, 300mm must have swept bends and

channels. All benching to be a minimum 40mm thick granolithic concrete trowelled to

a smooth finish.

Ironwork In Manholes

If the chamber is less than 3m deep we require double encapsulated step rungs

unless otherwise approved. If the chamber is over 3m deep we require hot dipped

galvanised mild steel ladders. There must be 900mm between ladder and back of

shaft. Depth is measured from finished cover level to the top of the benching. The

maximum distance between cover level and the first step must be 675mm.

Brickwork

Min 2 max 4 courses under frame and must be solid class B engineering bricks or

concrete spacing rings neatly pointed up. English Bond to be used on all brickwork.

Sulphate resisting cement must be used in all locations.

Cover and Frames

Cover slab opening, cover and frames must be 675 x 675 unless otherwise approved.

DN400 shall be used at all locations. On spine roads must be 150mm deep. On

residential cul-de-sacs 100mm may be used subject to approval. Frames for

manhole covers should be bedded in a polyester resin bedding mortar in all situations

where covers are sited in NRSWA Road Categories I, II or III.

'Infill' type covers should not be used.

In block paved areas 150mm deep frames must be used (in accordance with cl 2.8.6

SfA6 p.25)

Laterals

They should be laid to the same standard as public sewers. They should have no

changes of line or gradient between the sewer and the demarcation chamber. They

should have an adoptable manhole as the demarcation chamber unless there is only

on property when a plastic chamber to BS EN 13598-2:2009 is allowed. Lockable

B125 and A15 covers may be allowed in certain locations subject to approval. The

demarcation should be inside the boundary of the property, no more than 1m inside

the boundary, preferably in the driveway and not in the wheel tracks of vehicles.

FOUL WATER

Manhole

Pipe line

Direction Arrow

Rising Main

Demarcation Chamber*

SURFACE WATER

Manhole

Pipe line

Direction Arrow

Demarcation Chamber*

HIGHWAY DRAINAGE

Manhole

Gully

Highway Drain /

Gully Connection

OTHER

Existing Sewers

to be abandoned/

grubbed up in accordance with

Severn Trent Water Specification

* Demarcation chambers to be constructed as per

adoptable manhole construction details depending

on chamber depth. A 450Ø Inspection chamber

can be used providing lateral only serves one plot.

X X X X

Client

Title

Status

Date CreatedScale @ A0

PM/Checked byDrawn By

Drawing NumberRev

Project

Job Ref

rpsgroup.com/uk

c 2018 RPS Group

Notes

1. This drawing has been prepared in accordance with the scope of RPS’s

appointment with its client and is subject to the terms and conditions of that

appointment. RPS accepts no liability for any use of this document other than

by its client and only for the purposes for which it was prepared and provided.

2. If received electronically it is the recipients responsibility to print to correct scale.

Only written dimensions should be used.

MAKING

COMPLEX

EASY

Salisbury House, 2A Tettenhall Road,

Wolverhampton, West Midlands, WV1 4SA

T: 01902 925500 E: [email protected]

Preliminary AG

AAC5560

NJEJ

1:200

04.03.20

900-3 P01

St. Modwen Homes

Phase 2B

Uttoxeter

Engineering Layout

Sheet 2

Rev Description Date Initial Checked

P01 Latest Layout added, slight amendments made

to drainage.

20.03.20 NJEJ AG

For guidance only. Do not scale off this drawing

1:20 -

5m4m400mm

3m300mm

2m200mm

1m100mm0

0

20001800160014001200800mm600mm400mm200mm0

9m 10m0 1m 2m 3m 4m 5m 6m 7m 8m

1000

1:100-

1:50 -1:5 - 500mm

P/2020/00671Received 02/07/2020

AutoCAD SHX Text
H
AutoCAD SHX Text
PUBLIC DRAINAGE
AutoCAD SHX Text
G
AutoCAD SHX Text
D
AutoCAD SHX Text
D
nick.jeavons
Text Box
R9061-RPS-20-00-DR-C-9003