a118. Extron Sw_vga-Ars

Embed Size (px)

Citation preview

  • 7/28/2019 a118. Extron Sw_vga-Ars

    1/28

    Extron USA - WestHeadquarters

    +800.633.9876InsideUSA/CanadaOnly

    +1.714.491.1500

    +1.714.491.1517FAX

    Extron USA - East

    +800.633.9876InsideUSA/CanadaOnly

    +1.919.863.1794

    +1.919.863.1797FAX

    Extron Europe

    +800.3987.6673InsideEuropeOnly

    +31.33.453.4040

    +31.33.453.4050 FAX

    ExtronAsia

    +800.7339.8766InsideAsiaOnly

    +65.6383.4400

    +65.6383.4664FAX

    Extron Japan

    +81.3.3511.7655+81.3.3511.7656 FAX

    Extron China

    +400.883.1568InsideChinaOnly

    +86.21.3760.1568

    +86.21.3760.1566 FAX

    Extron Middle East

    +971.4.2991800+971.4.2991880 FAX

    2009 Extron Electronics. All rights reserved.

    Users M

  • 7/28/2019 a118. Extron Sw_vga-Ars

    2/28

    Precautions

    This symbol is intended to alert the user of importantoperating and maintenance (servicing) instructions inthe literature provided with the equipment.

    This symbol is intended to alert the user of thepresence of uninsulated dangerous voltage withinthe products enclosure that may present a risk ofelectric shock.

    CautionReadInstructions Read and understand all saety and operating

    instructions beore using the equipment.

    Retain Instructions The saety instructions should be kept or uturereerence.

    Follow Warnings Follow all warnings and instructions marked on theequipment or in the user inormation.

    Avoid Attachments Do not use tools or attachments that are notrecommended by the equipment manuacturer because they may behazardous.

    WarningPower sources This equipment should be operated only rom the power source

    indicated on the product. This equipment is intended to be used with a main powersystem with a grounded (neutral) conductor. The third (grounding) pin is a saetyeature, do not attempt to bypass or disable it.

    Power disconnection To remove power rom the equipment saely, remove all powercords rom the rear o the equipment, or the desktop power module (i detachable),or rom the power source receptacle (wall plug).

    Power cord protection Power cords should be routed so that they are not likely to bestepped on or pinched by items placed upon or against them.

    Servicing Reer all servicing to qualifed service personnel. There are no user-serviceable parts inside. To prevent the risk o shock, do not attempt to servicethis equipment yoursel because opening or removing covers may expose you todangerous voltage or other hazards.

    Slots and openings I the equipment has slots or holes in the enclosure, these areprovided to prevent overheating o sensitive components inside. These openingsmust never be blocked by other objects.

    Lithium battery There is a danger o explosion i battery is incorrectlyreplaced. Replace it only with the same or equivalent type recommended bythe manuacturer. Dispose o used batteries according to the manuacturersinstructions.

    Ce symbole sert avertir lutilisateur que ladocumentation fournie avec le matriel contient desinstructions importantes concernant lexploitation etla maintenance (rparation).

    Ce symbole sert avertir lutilisateur de la prsencedans le botier de lappareil de t ensions dangereusesnon isoles posant des risques dlectrocution.

    AttentionLire les instructions Prendre connaissance de toutes les consignes de

    scurit et dexploitation avant dutiliser le matriel.

    Conserver les instructions Ranger les consignes de scurit afn de pouvoirles consulter lavenir.

    Respecter les avertissements Observer tous les avertissements et consignesmarqus sur le matriel ou prsents dans la documentation utilisateur.

    Eviter les pices de fxation Ne pas utiliser de pices de fxation ni doutilsnon recommands par le abricant du matriel car cela risquerait de posercertains dangers.

    AvertissementAlimentationsNe aire onctionner ce matriel quavec la source dalimentation

    indique sur lappareil. Ce matriel doit tre utilis avec une alimentation principalecomportant un fl de terre (neutre). Le troisime contact (de mise la terre) constitueun dispositi de scurit : nessayez pas de la contourner ni de la dsactiver.

    Dconnexion de lalimentationPour mettre le matriel hors tension sans danger,dconnectez tous les cordons dalimentation de larrire de lappareil ou du moduledalimentation de bureau (sil est amovible) ou encore de la prise secteur.

    Protection du cordon dalimentation Acheminer les cordons dalimentation demanire ce que personne ne risque de marcher dessus et ce quils ne soient pascrass ou pincs par des objets.

    Rparation-maintenance Faire excuter toutes les interventions de rparation-maintenance par un technicien qualif. Aucun des lments internes ne peut trerpar par lutilisateur. Afn dviter tout danger dlectrocution, lutilisateur ne doitpas essayer de procder lui-mme ces oprations car louverture ou le retrait descouvercles risquent de lexposer de hautes tensions et autres dangers.

    Fentes et orifces Si le botier de lappareil comporte des entes ou des orifces, ceux-ciservent empcher les composants internes sensibles de surchauer. Ces ouverturesne doivent jamais tre bloques par des objets.

    Lithium Batterie Il a danger dexplosion sll y a remplacment incorrect de la batterie.Remplacer uniquement avec une batterie du meme type ou dun ype equivalentrecommande par le constructeur. Mettre au reut les batteries usagees conormementaux instructions du abricant.

    Safety Instructions English

    Consignes de Scurit Franais

    Sicherheitsanleitungen DeutschDieses Symbol soll dem Benutzer in der imLieferumfang enthaltenen Dokumentationbesonders wichtige Hinweise zur Bedienung undWartung (Instandhaltung) geben.

    Dieses Symbol soll den Benutzer darauf aufmerksammachen, da im Inneren des Gehuses diesesProduktes gefhrliche Spannungen, die nicht isoliertsind und die einen elektrischen Schock verursachenknnen, herrschen.

    AchtungLesen der Anleitungen Bevor Sie das Gert zum ersten Mal verwenden,

    sollten Sie alle Sicherheits-und Bedienungsanleitungen genau durchlesenund verstehen.

    Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheitdes Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall daraufzurckgreien knnen.

    Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise undAnleitungen auf dem Gert oder in der Benutzerdokumentation.

    Keine Zusatzgerte Verwenden Sie keine Werkzeuge oder Zusatzgerte,die nicht ausdrcklich vom Hersteller empfohlen wurden, da diese eineGefahrenquelle darstellen knnen.

    VorsichtStromquellen Dieses Gert sollte nur ber die auf dem Produkt angegebene

    Stromquelle betrieben werden. Dieses Gert wurde fr eine Verwendung mit einerHauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der dritteKontakt ist r einen Erdanschlu, und stellt eine Sicherheitsunktion dar. Diesesollte nicht umgangen oder auer Betrieb gesetzt werden.

    Stromunterbrechung Um das Gert auf sichere Weise vom Netz zu trennen, solltenSie alle Netzkabel aus der Rckseite des Gertes, aus der externen Stomversorgung(falls dies mglich ist) oder aus der Wandsteckdose ziehen.

    Schutz des Netzkabels Netzkabel sollten stets so verlegt werden, da sie nicht imWeg liegen und niemand darauf treten kann oder Objekte darauf- oder unmittelbardagegengestellt werden knnen.

    Wartung Alle Wartungsmanahmen sollten nur von qualiziertem Servicepersonaldurchgefhrt werden. Die internen Komponenten des Gertes sind wartungsfrei.Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall, diesesGert selbst ffnen, da beim Entfernen der Abdeckungen die Gefahr eineselektrischen Schlags und/oder andere Gefahren bestehen.

    Schlitze und ffnungen Wenn das Gert Schlitze oder Lcher im Gehuse aufweist,dienen diese zur Vermeidung einer berhitzung der empndlichen Teile imInneren. Diese nungen dren niemals von anderen Objekten blockiert werden.

    Litium-Batterie Explosionsgefahr, falls die Batterie nicht richtig ersetztwird. Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen

    vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen Sieverbrauchte Batterien bitte gem den Herstelleranweisungen.

    Este smbolo se utiliza para advertir al usuariosobre instrucciones importantes de operacin ymantenimiento (o cambio de partes) que se deseandestacar en el contenido de la documentacinsuministrada con los equipos.

    Este smbolo se utiliza para advertir al usuario sobrela presencia de elementos con voltaje peligroso sinproteccin aislante, que puedan encontrarse dentrode la caja o alojamiento del producto, y que puedanrepresentar riesgo de electrocucin.

    PrecaucionLeer las instrucciones Leer y analizar todas las instrucciones de operacin y

    seguridad, antes de usar el equipo.

    Conservar las instrucciones Conservar las instrucciones de seguridad parautura consulta.

    Obedecer las advertencias Todas las advertencias e instrucciones marcadasen el equipo o en la documentacin del usuario, deben ser obedecidas.

    Evitar el uso de accesorios No usar herramientas o accesorios que nosean especifcamente recomendados por el abricante, ya que podrianimplicar riesgos.

    AdvertenciaAlimentacin elctrica Este equipo debe conectarse nicamente a la uente/tipo

    de alimentacin elctrica indicada en el mismo. La alimentacin elctrica de esteequipo debe provenir de un sistema de distribucin general con conductor neutroa tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no puenteariani eliminaria.

    Desconexin de alimentacin elctrica Para desconectar con seguridad la acometidade alimentacin elctrica al equipo, desenchuar todos los cables de alimentacinen el panel trasero del equipo, o desenchuar el mdulo de alimentacin (si ueraindependiente), o desenchuar el cable del receptculo de la pared.

    Proteccin del cables de alimentacin Los cables de alimentacin elctrica se debeninstalar en lugares donde no sean pisados ni apretados por objetos que se puedanapoyar sobre ellos.

    Reparaciones/mantenimiento Solicitar siempre los servicios tcnicos de personalcalifcado. En el interior no hay partes a las que el usuario deba acceder. Para evitarriesgo de electrocucin, no intentar personalmente la reparacin/mantenimientode este equipo, ya que al abrir o extraer las tapas puede quedar expuesto a voltajespeligrosos u otros riesgos.

    Ranuras y aberturas Si el equipo posee ranuras o orifcios en su caja/alojamiento,es para evitar el sobrecalientamiento de componentes internos sensibles. Estasaberturas nunca se deben obstruir con otros objetos.

    Batera de litio Existe riesgo de explosin si esta batera se coloca en la posicinincorrecta. Cambiar esta batera nicamente con el mismo tipo (o su equivalente)recomendado por el abricante. Desachar las bateras usadas siguiendo lasinstrucciones del abricante.

    Instrucciones de seguridad Espaol

    ExtronElectronicsor a period o thrthe warranty periExtron Electronicsto whatever exten

    condition, providpurchase and des

    USA, Canadand CentralExtron USA1001 East BaAnaheim, CAU.S.A.

    Europe, AfrExtron EuroHanzeboule3825 PH AmThe Netherla

    Asia:Extron Asia135 Joo SengPM IndustriSingapore 36Singapore

    This Limited Warhandling care, eleExtron authorized

    If it has been deteApplications Eng(Asia), or 81.3.351

    will begin the repUnits must be retassume the risk oserial number andcontact in case the

    ExtronElectronicto the product anduse. In no event wdamages resultinadvised o such d

    Please note that laprovisions o this

  • 7/28/2019 a118. Extron Sw_vga-Ars

    3/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    4/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    5/28

    ii SW VGArs / Ars Series Switchers Table of Contents

    Table of Contents, contd

    Chapter 4 Remot e Control .................................................. 4-1

    Simple Instruction Set Control ....................................... 4-2

    Host-to -sw itcher comm unicat ions ........................................ 4-2

    Swit cher-initiat ed (unsolicited ) me ssa ge s ............................ 4-3

    Error responses ...................................................................... 4-3

    Time o ut ..................... .............. ............. .............. .............. ...... 4-4

    Using th e comm a nd /response ta ble ..................................... 4-4

    Symbol def initions ................................................................ 4-4

    Comm a nd /response t a ble f or SIS com ma nd s ....................... 4-5

    Window s-Based Program Control ................................. 4-7

    Insta lling th e soft w a re .......................................................... 4-7

    Using th e soft w a re ................................................................ 4-8

    Upda ting firmw a re ................................................................ 4-9Dow nload ing th e firmw are f rom the Web site . .. . . .. . . .. . . .. . . . 4-9

    Loa ding t he firmw a re to the sw itcher .............................. 4-11

    Using th e help system ......................................................... 4-14

    VSW I AAP Remote Control ............................................ 4-14

    Contact Closure Remot e Control ................................. 4-15

    IR 102 Infrared Remot e Control ................................... 4-15

    Appendix A Reference Inform ation ............................ A-1

    Specifications ......................................................................... A-2

    Part Num bers .......................................................................... A-5

    Sw itche rs ............. .............. .............. ............... .............. ......... A-5

    Included parts ....................................................................... A-5

    Cables .................................................................................... A-5

    Accessories ............................................................................ A-6

    All trademarks mentioned in this manual are the properties of their respective owners.

  • 7/28/2019 a118. Extron Sw_vga-Ars

    6/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    7/28

    SW VGArs / Ars Series Switchers Introduction

    Introduction, contd

    1-4

  • 7/28/2019 a118. Extron Sw_vga-Ars

    8/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    9/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    10/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    11/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    12/28

    SW VGArs / Ars Series Switchers Installation

    Installation, contd

    2-10

    Identif ying t he Board Version andSetting the SW VGA/Ars Jumpers

    If you plan to use the switcher with VSW I AAP remotecontrols, you must configure the switcher. It is moreconvenient to do this before installing it in a rack or

    furniture and making connections.

    Using the SW VGA/Ars switcher with VSW I AAP controlpanels requires you to set internal jumpers in the switcher.When you open the switcher, you can also check the circuit

    board installed in the switcher to ensure that it is compatiblewith the VSW I AAP control panels.

    On the VSW I A AP remot e control, ensure thatjumper J6 is installed. Refer to the VSW I AAP manualfor details.

    1. If applicable, disconnect all power to the switcher and anyattached devices.

    2. Remove the eight screws from the switcher (three on eachside of the switcher and two on top) (figure 2-8). Removethe two connector nuts from the Remote connector ( 6 onfigure 2-3 and figure 2-4) and each VGA connector ( 2 and4 on figure 2-3 and figure 2-4) on the rear panel of the

    switcher. Lift the top cover off of the switcher.

    SWVG

    A/ArsSE

    RIES

    VGA/A

    UDIO

    SWITC

    HER

    6

    5

    4

    3

    2

    1

    MODE

    NORM

    AL

    AUTO

    AUTO

    SWITC

    H

    ACTIV

    E

    Lift CoverStraight Up

    Remove (2)nuts each sideof each 9-pin and15-pin connector.

    Figu re 2 -8 Remo v in g t he cove r

  • 7/28/2019 a118. Extron Sw_vga-Ars

    13/28

    SW VGArs / Ars Series Switchers Installation

    Installation, contd

    Configuring t he sw itcher

    There are six jumpers on the circuit board, numbered JMP5,JMP7, JMP9, JMP11, JMP 13, and JMP15, that control connectionwith one or more VSW I AAP control panels (figure 2-9 and

    figure 2-10).

    OPEN CLOSED

    All jumpers are set open (removed) by default.The jumpers in the table below must be set closed(installed) when a VSW I AAP is connected to theassociated input.

    Close the indicated jumpers in the table belowto adjust the appropriate settings.

    Jumper

    Input 1

    Input 2

    Input 3

    JMP5

    JMP7

    JMP9

    JumperVSW I AAP

    connected to:VSW I AAP

    connected to:

    Input 4

    Input 5

    Input 6

    JMP11

    JMP13

    JMP15

    Figu re 2 -10 Jum per po s i t i on s vs. VSW I A AP

    i n p u t co n ne ct i o n s

    These jumpers enable/disable VGA connector pin 5 (control) foreach input. Close (install) the jumper for a specific VGA input

    to allow the VSW I AAPs show me signal to select that input.

    When an input is not connected via a VSW I AAP, thatinputs jumper should be in the default (open) position.

    Each jumper, when closed (installed) allows the switcher toreceive the show me signal from the VSW I AAP on thatinputs VGA connector. When a jumper is open (removed) thatinput cannot receive the signal.

    Auto switch mode must be disabled when using the

    switcher with one or more VSW I AAP remote controls.If the auto switch mode is enabled, the input cannot beselected using the show me function.

    2-12

  • 7/28/2019 a118. Extron Sw_vga-Ars

    14/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    15/28

    SW VGArs / Ars Series Switchers Operation

    Operation, contd

    3-4

    Selecting auto switch mode

    Press and hold the Input 1/Mode button while you press andrelease the Input 3/Auto button. The Auto Switch Active LEDturns on, indicating auto switch mode. Release theInput 1/Mode button.

    Auto switch mode must be disabled when using theswitcher with one or more VSW I AAP remote controls.If the auto switch mode is enabled, the input cannot beselected using the show me function.

    Locking the f ront panel (Executive mode)

    To toggle the front panel lock on and off, press and hold theInput 2/Normal button and the Input 3/Auto button forapproximately 3 seconds. All front panel LEDs flash three timesto indicate the mode change.

    All input LEDs blink once if you attempt a front paneloperation while the panel is locked.

    Selecting an input in normal switch mode

    To select an input using the front panel buttons, press andrelease the button for the desired input (must be in normalswitch mode). The LED for the selected input lights.

    An input can also be selected by an RS-232 device or a remotecontrol device (see chapter 4, Remote Control).

  • 7/28/2019 a118. Extron Sw_vga-Ars

    16/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    17/28

    SW VGArs / Ars Series Switchers Remote Control

    Remote Control, contd

    Timeout

    Pauses of 10 seconds or longer between command ASCIIcharacters result in a timeout. The command operation isaborted with no other indication.

    Using t he command/response t able

    The command/response table is on the next page. Lowercaseletters are allowed in the command field only as indicated.Symbols are used throughout the table to represent variables inthe command/response fields. Command and responseexamples are shown throughout the table. The ASCII to HEXconversion table below is for use with the command/responsetable.

    Symbol definit ions= CR/LF (carriage return/line feed) (0x0D 0A)

    = space

    X1 = Input number 0 through 6 (0 = output mute)

    X2 = Input signal status 0 = no signal detected1 = signal detected

    X3 = On/off status 0 = off 1 = on

    X4 = Software version x.xx

    X5 = Switch mode 1 = normal switch mode2 = auto switch mode

    ASCII to HEX Conversion Table

    4-4

  • 7/28/2019 a118. Extron Sw_vga-Ars

    18/28

    SWVGArs/ArsSeries

    SwitchersRemoteCon

    trol

    4-5

    Command/response table for SIS commands

    Command ASCII Command Response Addit(host to switcher) (switcher to host)

    Input selection

    Select video and audio input X1 ! In X1 All Select in

    Select video input only X1& In X1Vid Select in

    Select audio input only X1$ In X1Aud Select in

    Input video sensing

    Request all inputs status 0S Sig X2 1 X2 2... X2 n Each X2

    starting inputs f

    Example (SW6 VGArs): 0S Sig111010 The inpu

    No signRequest one inputs status X1S X2 X1 s sig

    Video M ute

    Mute video 1 B/b Vmt X3 Video m

    Unmute video 0 B/b Vmt X3 Video m

    Read video mute B/b X3 Video m

    Audio M ute

    Mute audio 1 Z/z Amt X3 Audio m

    Unmute audio 0 Z/z Amt X3 Audio m

    Read audio mute Z/z X3 Audio m

  • 7/28/2019 a118. Extron Sw_vga-Ars

    19/28

    SWVGArs/ArsSeriesSwitchers

    RemoteControl

    Command/response table for SIS commands (continued)

    Command ASCII Command Response Addit(host to switcher) (switcher to host)

    Front panel mode

    Set normal switch mode 1# F1 Set swit

    Set auto switch mode 2# F2 Set swit

    Front panel lock (Executive m ode)

    Lock front panel 1X Exe1 Lock fro

    Unlock front panel 0X Exe0 Unlock

    Show front panel lock status X X3 Show fr0 = unlo

    View, information, part num ber, and firmw are requests

    Information request I/i V X1A X1FX5Vmt X3Amt X3

    Example V2A2F2Vmt 0Amt 1

    Video inauto; vid

    Request for part number N/n 60-xxx-xx

    Query software version Q/q X4 Software

    4-6

  • 7/28/2019 a118. Extron Sw_vga-Ars

    20/28

    SW VGArs / Ars Series Switchers Remote Control

    Window s-Based Program Control

    The Windows-based Extron Universal Switcher ControlProgram, which communicates with the switcher via the RS-232port, provides an easy way to configure and operate the

    SW VGArs / Ars Series switchers. The program is compatiblewith Windows 2000 and Windows XP.

    Installing the software

    The program is contained on the Extron Software Products disk.Install the software as follows:

    1. Insert the disk into the drive. The installation programshould start automatically. If it does not self-start, runLaunch.exe from the disk.

    The Extron software disk window appears (figure 4-2).

    Fi gu re 4 -2 So f tw a re d i s k w i ndo w

    2. Click the Software tab (figure 4-2).

    3. Scroll to the desired program and click Install (figure 4-3).

    Figu re 4 -3 Sof tw are ins ta l l a t i on

    4-7

    R t C t l td

  • 7/28/2019 a118. Extron Sw_vga-Ars

    21/28

    SW VGArs / Ars Series Switchers Remote Control

    Remote Control, contd

    4. Follow the on-screen instructions. By default, the Windowsinstallation of the Universal Switchers Control Programcreates a C:\Program Files\Extron\UnivSW, and it placesfour icons into a group folder named ExtronElectronics\Universal Switcher. The four installed icons

    are: Check for Universal Switcher Updates Uninstall Universal Switcher Universal Switcher Control Program Universal Switcher Help

    Using the soft w are

    Run the program as follows:

    1. Click Start> Programs > Extron Electronics >

    Universal Switcher Control Pgm.

    2. Click the comm port that is connected to theswitchers RS-232 port.

    3. The Extron Universal Switcher Control Program window(figure 4-4) displays the input signal status for each input(signal present or not present) and the selected input.

    Figu re 4 -4 Un ive rsa l Sw i t che r Con t r o l p r og ram

    w i n d o w

    4-8

    Remote Control contd

  • 7/28/2019 a118. Extron Sw_vga-Ars

    22/28

    SW VGArs / Ars Series Switchers Remote Control

    Remote Control, contd

    4-10

    2. On the Download Center screen, click the SW VGA SeriesDownload link.

    Figu re 4 -6 SW VGA Ar s f i rm w are

    3. Complete the Personal Information form and click theDownload button.

    Fi gu re 4 -7 Pe rsona l i n f o rm a t i on f o rm

    4. Follow the instructions on the rest of the download screensto save the executable firmware file to your computer. Notethe folder to which you save the file.

    5. In the Windows Explorer or other file browser, locate thedownloaded executable file, and double-click on it to openit.

    6. Follow the instructions on the Installation Wizard screens toinstall the new firmware on your computer. A ReleaseNotes file, giving information on what has changed in thenew firmware version, and a set of instructions for updatingthe firmware are also loaded.

    Remote Control contd

  • 7/28/2019 a118. Extron Sw_vga-Ars

    23/28

    SW VGArs / Ars Series Switchers Remote Control

    Remote Control, cont d

    3. If you have not updated firmware for the SW VGA switcherbefore, on the Add Device screen, select the RS-232 tab.

    If you have updated firmware for this model, click Cancel.The Firmware Loader window appears. Proceed to step 6.

    Figu re 4-8 Ad d Dev ice screen

    Although the screen also has a TCP/IP tab, the switcherdoes not have a LAN port. Do not select the TCP/IP tab.

    4. From the drop-down menus on the RS-232 screen, select theappropriate Com port number (obtained from your system

    administrator) and baud rate (the default is 9600).

    5. Click OK. The Firmware Loader window appears.

    Fi gu re 4 -9 Ex t r on Fi rmw a re Loade r w i ndo w

    6. Select the SW VGArs and click File> Open. The ChooseFirmware File screen appears.

    4-12

    Remote Control contd

  • 7/28/2019 a118. Extron Sw_vga-Ars

    24/28

    SW VGArs / Ars Series Switchers Remote Control

    Remote Control, cont d

    Using the help system

    For information about program features, you can access the helpprogram in any of the following ways:

    Click Start> Programs> Extron Electronics >

    Universal Switcher Control Help. From within the Windows-based switcher control

    program, select Help> Contentson the task bar.

    From within the Windows-based switcher controlprogram, press the F1 key.

    VSW I AAP Remote Control

    Each input of an SW VGArs / Ars Series switcher can beconnected to a VSW I AAP passive interface. The VSW I AAPfeatures a computer video input and pass-through, anunbalanced stereo input and pass-through, and an input select(Show Me) button. Pressing the VSW I AAPs Show Me buttoncauses the switcher to select the input connected via that AAP.

    SW6 VGA ArsREMOTE100-240V 0.2A INPUTS

    1

    2

    3

    4

    5

    50-60Hz

    OUTPUTOUTPUT

    L R

    SW6 VGA Ars

    6

    Projector

    VSW IAAP

    SW6 VGA Ars

    VSW I AAPCOMPUTERAUDIO

    SHOWME

    VSW IAAP

    VSW IAAPCOMPUTERAUDIO

    SHOW ME

    VSW IAAP

    VSW I AAPCOMPUTERAUDIO

    SHOW ME

    VSW IAAP

    VSW I AAPCOMPUTERAUDIO

    SHOWME

    VSW IAAP

    VSW IAAPCOMPUTERAUDIO

    SHOW ME

    VSW IAAP

    VSW I AAPCOMPUTERAUDIO

    SHOW ME

    Figu re 4-12 VSW I AA P app l i ca t ion

    4-14

    Remote Control, contd

  • 7/28/2019 a118. Extron Sw_vga-Ars

    25/28

    SW VGArs / Ars Series Switchers Remote Control

    Remote Control, cont d

    4-16

  • 7/28/2019 a118. Extron Sw_vga-Ars

    26/28

  • 7/28/2019 a118. Extron Sw_vga-Ars

    27/28

    Reference Information, contd

  • 7/28/2019 a118. Extron Sw_vga-Ars

    28/28

    SW VGArs / Ars Series Switchers Reference InformationA-6

    Accessories

    Accessory Part number

    RSU 129 1U Universal rack shelf 60-190-01

    RSB 129 1U Basic rack shelf 60-604-01

    MBU 125 Under-desk mounting kit 70-077-01

    MBD 129 Through-desk mounting kit 70-077-02

    KP 6 remote control 60-111-20

    IR 102 remote control kit 70-224-01