Oxygen Permeation Analyzer8501
Features & Benefits
Advanced Technologies in Oxygen PermeationMeasurement
Digital electronics
OTR displayed as cc/m2/day orcc/100in2/day
Automated test routine
Scaleable analog outputs
RS232 output
Data logging capabilities
Low cost system
Accuracy traceable to currentNAMAS/N.I.S.T. standards
Sensor life indicator
Conforms to: ASTM D-3985 ISO 15105-2 DIN 53380 JIS K-7126 F2622-08
Produce Manufacturers Packaging Manufacturers Process Companies
Food Companies Converters Distributors R&D
Applications
Your solution to laboratory quality analysis of packag
Illinois’ 8501 offers a cost effectivesolution for those who need accurate,uncomplicated measurement of oxygentransmission rates (OTR) throughpermeable films.
The 8501 features state of the artelectronics that allow the user to initializetest or calibrate with the touch of abutton. Scaleable analog outputs allowthe user flexibility when connecting to achart recorder.
A standard RS232 port enables datalogging capabilities. The unique LIFEparameter indicates when the internaloxygen sensor needs to be replaced.
Illinois’ 8501 combines trace oxygensensitivity, rugged dependability, andexceptional ease of use in a compact,single chamber, precision oxygenpermeation analyzer.
The 8501 utilises our proprietary sensorto detect oxygen transmission ratesthrough flat film barriers. Flat filmsamples are clamped in a diffusionchamber. Pure oxygen (99.9%) is thenintroduced into the upper half of thechamber while an oxygen free carrier gasflows through the lower half. Molecules ofoxygen diffusing through the film into thelower chamber are conveyed to thesensor by the carrier gas.
Fast Analysis
Principle of Operation
This allows a direct measurement of theoxygen without using complex extrapolations.Oxygen transmission rate of the test film isdisplayed as either cc/m2/day orcc/100in2/day.
TEST FILM
SAMPLE TEST CHAMBER
O2 OUT
N2/O2 OUT
O2 IN
N2 IN
The proprietary sensor design of the8501 allows for extremely fast, accurateresults. In a head-to-head comparisonbetween the 8501 and its competitors,the 8501 was proven to be up to 4 timesfaster.
With a purge time of only 30 minutes andtest times as short as 20 minutes, the8501 is a must for high volumeproduction facilities.
With 2 button operation, the 8501 issimple to operate and requires littleor no special operator training. Theunit is easily calibrated to a certifiedNAMAS / N.I.S.T. traceablecalibration gas. This makes the testresults traceable to current NAMAS/ N.I.S.T. standards.
ing film barriers in a simple to use benchtop system.
400
350
300
250
200
150
100
50
00 10 20 30 40 50 60 70 80 90 100
Test Time
8501 Test Data
OxygenTransmissionRate
Although the 8501 is a stand-aloneinstrument, an RS232 port is provided forconnection to a PC. Supplied softwareallows users a graphical interface fordisplay, storage, and printout of the data.
The stored data can also be exported toa spreadsheet program such as Excel®or Lotus®. These programs allow you tograph and print the data or incorporate itinto analysis reports for customers ormanagement.
Easy to use software
Proven Accuracy
The data plot below illustrates that a testfilm of 340cc/100in2/day and a test run of60 minutes yields only about8cc/100in2/day (2.3%) increase. This iscompared to the 332cc/100in2/day sensedwithin the first 20 minutes.
Many applications will find that a shorter20 minute test routine will consistentlyproduce reliable and adequate results.
PC Supplied Software Typical Exported Excel® File
Illinois Instruments reserve the right to change specifications without notice. 10/03
Illinois Instruments, Inc (U.S)2401 Hiller Ridge RoadJohnsburg, Illinois 60051U.S.ATel: +1 815 344 6212Fax: +1 815 344 6332E-mail: [email protected]
Systech Instruments Ltd (UK)17 Thame Park Business Centre,Wenman Road,Thame, Oxfordshire OX9 3XATel: +44 (0)1844 216838Fax: +44 (0)1844 217220E-mail: [email protected]
Illinois Instruments (Thailand)6th fl Nopnarong Bldg No7Ladprao23, Jatujak, Bangkok 10900ThailandTel: +66 (0)2938 0798Fax: +66 (0)2938 1058E-mail: [email protected]
Systech Illinois (China)Room 519, No.3 FuCheng BuildingNo. 900 Quyang Rd, Hongkou district,Shanghai, China 200434Tel: +86 21 65533022Fax: +86 21 65539651Email: [email protected]
8002As 8001, but tests only dry or wet(assumed 100% RH).
82002 station for films orpackages.
8501Reduced specification singlestation for film or package,dry test only.
80012 stations for films or packages,precise humidity control, canswitch between wet or dry sampleswithin minutes.
870011 stations for films orpackages.
Illinois’ range meets the requirement for the testing of any application.
OTR Test RangeFilms0.0003 - 28,000 cc/100in2/day(0.005 - 432,000 cc/m2/day) No masking required0.0005 - 28,000 cc/100in2/day(0.008 - 432,000 cc/m2/day) No masking required
0.0001 - 5,000 cc/100in2/day(0.04 - 100,000 cc/m2/day) No masking required0.07 - 68,000 cc/100in2/day(1 - 99,999 cc/m2/day) No masking required
Package0.00004 - 1,000 cc/pack/day
Test Temperature Range41°F to 122°F (5°C to 50°C)59°F to 104°F (15°C to 40°C)
Controlled RH TestingDry and 20% to 90% RHDry and Unknown Wet RH (Assumed saturated or 100% RH)Dry only
ExpansionExpandable up to 5 Modules (Total 12 test cells)Expandable up to 5 Modules (Total 66 test cells)
Test Sample SizeFilms 7.75 in2
Films 15.50 in2
Packages
CalibrationFilms or NIST gas
Automatic Temperature Control
Illinois 8000 Series - Oxygen Permeation Analyzers
� � �
�
� � � �
� � ��
��
� � �
� � �
� � ��
� � � �
� � � �
� � � �
�
�
ambient
ambient
8001 e-netAs 8001, with new coulometricoxygen sensor and an integratedcomputer.
8001LAs 8001, with new coulometricoxygen sensor.
8003As 8001, but tests dryonly.
Technical Specifications 8001
�
�
�
�
�
�
�
�
�
8001e-net
�
�
�
�
�
�
�
�
�
8001L 8002 8003 8200 8501
��
�
ambient
�
�
�
ambient
��
8700