4
Oxygen Permeation Analyser Barrier Film PET Bottles Containers Canisters Flexible pouches Bags Applications Features & Benefits combines the outstanding quality of Systech’s Oxygen Permeation Analyser with a unique, online ‘Remote Consultant TM ’ capability The Remote Consultant TM guidance utility saves time and money. New and improved oxygen sensor enhances analytical precision. Integrated computer saves valuable laboratory space and compatibility considerations. Widest measuring range in the market providing research grade flexibility. Electronic flow, temperature and humidity control for ultimate responsiveness and repeatability. System validation with certified gas or film for speed and convenience. Analytical Systems Manufactured Traceable to NIST. No archaic liquid coolants, catalysts or special gas mixtures required. Conforms to: ASTM D-3985 ISO 15105-2 DIN 53380 JIS K-7126 F2622-08 New

Oxygen Permeation Analyser - YAGASystech 8000 Series - Oxygen Permeation Analysers ambient ambient 8001e-net As8001,withnewcoulometric oxygensensorandanintegrated computer. 8001L As8001,withnewcoulometric

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Oxygen Permeation Analyser - YAGASystech 8000 Series - Oxygen Permeation Analysers ambient ambient 8001e-net As8001,withnewcoulometric oxygensensorandanintegrated computer. 8001L As8001,withnewcoulometric

Oxygen Permeation Analyser

Barrier Film PET Bottles Containers Canisters Flexible pouches Bags

Applications

Features & Benefits

combines the outstanding quality of Systech’sOxygen Permeation Analyser with a unique,online ‘Remote ConsultantTM’ capability

The Remote ConsultantTM guidanceutility saves time and money.

New and improved oxygen sensorenhances analytical precision.

Integrated computer saves valuablelaboratory space and compatibilityconsiderations.

Widest measuring range in the marketproviding research grade flexibility.

Electronic flow, temperature andhumidity control for ultimateresponsiveness and repeatability.

System validation with certified gas orfilm for speed and convenience.

Analytical Systems ManufacturedTraceable to NIST.

No archaic liquid coolants, catalysts orspecial gas mixtures required.

Conforms to: ASTM D-3985 ISO 15105-2 DIN 53380 JIS K-7126 F2622-08

New

Page 2: Oxygen Permeation Analyser - YAGASystech 8000 Series - Oxygen Permeation Analysers ambient ambient 8001e-net As8001,withnewcoulometric oxygensensorandanintegrated computer. 8001L As8001,withnewcoulometric

The exceptional e-net facility has a dual purpose for the user; for remote access to theanalyser or to utilise Systech’s Remote ConsultantTM for guidance.

The Remote Consultant offers:

Help and Support - Our experts can trainand communicate all aspects of theanalyser operation by navigating youthrough the intuitive menu system onscreen.

On-line instrument diagnostic - Our ownTechnical Engineers can run completesystem diagnostics, baselines, sample testsand even calibrate your analyser assuring itremains in optimum operational condition.

The integral computer eliminates the costand confusion of sourcing and configuringa work station, whilst saving on valuablelaboratory space.

The intuitive Windows based softwareoffers:

Easy input and recall of operatingparameters and test protocols.

User-friendly data tracking, searches,sorts, storage and output capabilities.

Complete system diagnostics.

On-line operation assistance - Methoddevelopment for unique samples - ourTechnical Engineers can makerecommendations and set-up your testprofiles with minimal effort and time.

Only the user can initiate connectivity with the Remote Consultant™ allowing secure remotesupport. Once the work session has ended, the connection is automatically closed. All thesebenefits are at a fraction of the cost in comparison to traditional analytical support options.

Remote ConsultantTM

Coulometric oxygen sensor

Integrated computer

Software

Software

The analyser has a new enhanced oxygensensor offering:

Extremely fast purge down time.

Accurate readings at the lowest levelsenhancing analytical precision.

The highest quality sensor in the marketwith the lowest replacement cost.

Automatic Barometric PressureCompensation.

Set Up

Data Graph

Report

Page 3: Oxygen Permeation Analyser - YAGASystech 8000 Series - Oxygen Permeation Analysers ambient ambient 8001e-net As8001,withnewcoulometric oxygensensorandanintegrated computer. 8001L As8001,withnewcoulometric

Our test laboratory will perform your Permeation Testing and Headspace Analysis. Whetheryou are developing innovative materials and packages or validating that your supplier ismeeting specification. We can exceed your expectations with:

Competitive PricesFast Turnaround

Independent non-biased results25 Years Experience

Laboratory Testing Services

Research grade flexibility.

Research grade accuracy andrepeatability.

Quality Assurance orientated speed andagility.

The 8001 e-net analyser gives you the widest measurement range in the market providing:

Measurement Range ranging from 0.005cc/m2/day to 432,000.

Up to five Expansion Modules available toincrease testing throughput.

Test gas and carrier gas flow is controlledby premium electronic flow controllers.

Widest sample temperature rangeavailable - 5°C to 50°C.

Accurate Relative Humidity range from20% to 90% RH.

This analyser offers precision electronic, temperature and humidity flow control providingultimate responsiveness and repeatability.

Fastest changeover from wet to dry sampleruns.

No need for archaic liquid coolants,catalysts or expensive gas mixtures - justsimple Nitrogen and Oxygen.

Utilising our proprietary coulometricsensor technology to detect oxygentransmission rates samples are clampedor attached to a diffusion chamber. Pureoxygen (99.9%) is then introduced intothe upper half of the chamber while anoxygen-free carrier gas flows through thelower half.

Molecules of oxygen diffusing through thesample into the lower chamber areconveyed to the sensor by the carrier gas.

Principle of Operation

This allows a direct measurement of theoxygen without using complexextrapolations. Oxygen transmission rateof the test sample is displayed as eithercc/m2/day or cc/100in2/day.

Widest measuring range

Precision control

TEST FILM

SAMPLE TEST CHAMBER

O2 OUT

N2/O2 OUT

O2 IN

N2 IN

Page 4: Oxygen Permeation Analyser - YAGASystech 8000 Series - Oxygen Permeation Analysers ambient ambient 8001e-net As8001,withnewcoulometric oxygensensorandanintegrated computer. 8001L As8001,withnewcoulometric

Systech Instruments have over 25 years experience of providing analysis solutions for a wide range of industries.From our manufacturing plant in the UK we produce gas analysers for industrial process industries, headspaceanalysers for monitoring gas flushing of food products, and our range of permeation analysers.

Systech reserve the right to change specifications without notice. 07/09

17 Thame Park Business Centre, Wenman Road,Thame, Oxfordshire OX9 3XATel: +44 (0)1844 216838 Fax: +44 (0)1844 217220E-mail: [email protected] www.systechinstruments.com

Illinois Instruments, inc2401 Hiller Ridge RoadJohnsburg, Illinois 60050U.S.ATel: +1 815 344 6212Fax: +1 815 344 6332E-mail: [email protected]

8002As 8001, but tests only dry or wet(assumed 100% RH).

82002 station for films orpackages.

8501Reduced specification singlestation for film or package,dry test only.

80012 stations for films or packages,precise humidity control, canswitch between wet or dry sampleswithin minutes.

870011 stations for films orpackages.

Systech’s range meets the requirement for the testing of any application.

OTR Test RangeFilms0.005 - 432,000 cc/m2/day(0.0003 - 28,000 cc/100in2/day) No masking required0.008 - 432,000 cc/m2/day(0.0005 - 28,000 cc/100in2/day) No masking required0.04 - 100,000 cc/m2/day(0.0001 - 5,000 cc/100in2/day) No masking required1 - 99,999 cc/m2/day(0.07 - 68,000 cc/100in2/day) No masking required

Package0.00004 - 1,000 cc/pack/day

Test Temperature Range5°C to 50°C (41°F to 122°F)15°C to 40°C (59°F to 104°F)

Controlled RH TestingDry and 20% to 90% RHDry and Unknown Wet RH (Assumed saturated or 100% RH)Dry only

ExpansionExpandable up to 5 Modules (Total 12 test cells)Expandable up to 5 Modules (Total 66 test cells)

Test Sample SizeFilms 50cm2

Films 100cm2

Packages

CalibrationFilms or NIST gas

Automatic Temperature Control

Systech 8000 Series - Oxygen Permeation Analysers

� � �

� � � �

� � ��

��

� � �

� � �

� � ��

� � � �

� � � �

� � � �

ambient

ambient

8001 e-netAs 8001, with new coulometricoxygen sensor and an integratedcomputer.

8001LAs 8001, with new coulometricoxygen sensor.

8003As 8001, but tests dryonly.

Technical Specifications 8001

8001e-net

8001L 8002 8003 8200 8501

��

ambient

ambient

��

8700