2.00 MATERIALS AND WORKMANSHIP

Page 2: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271

CONTENTS C20 Demolition C90 Alterations - spot items G20 Carpentry/ Timber framing/ First fixing L20 Doors/ Shutters/ Hatches L40 General glazing M20 Plastered/ Rendered/ Roughcast coatings M60 Painting/ Clear finishing N10 General fixtures/ furnishings/ equipment P12 Fire stopping systems P20 Unframed isolated trims/ skirtings/ sundry items P21 Ironmongery P31 Holes, Chases, Covers and Supports for services V90 Electrical installations - domestic Z10 Purpose made joinery Z20 Fixings and adhesives Z22 Sealants

Page 3: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/1

C20 DEMOLITION 05 SURVEY - Scope: Before starting work, carry out a survey and submit a report and method statement

covering the following: - Condition and demolition methods and sequences for the structures. - Removal methods of any hazardous materials. - Type and location of adjoining or surrounding premises which may be adversely affected

by the Works. - Identification, location, disconnection and removal of services. - Arrangements for protection of personnel and the public. - Arrangements for control of site transport and traffic. 10 EXTENT OF DEMOLITION - General: Subject to retention requirements specified elsewhere, demolish structures down to

floor level. 15 BENCH MARKS - Unrecorded bench marks and other survey information: Give notice when found. - Do not remove or destroy. 25 LOCATION OF SERVICES - Services affected by the Works: Locate and mark positions. - Mains services: Arrange with the appropriate authorities for locating and marking positions. 30 DISCONNECTION OF SERVICES ARRANGED BY CONTRACTOR - Responsibility: Before starting demolition arrange with the appropriate authorities for

disconnection of services and removal of fittings and equipment. 31 DISCONNECTION OF SERVICES ARRANGED BY EMPLOYER - Responsibility: The Employer will arrange disconnection of services and removal of fittings

and equipment prior to demolition. - Before starting demolition ensure that disconnections have been carried out. 32 DISCONNECTION OF DRAINS - General: Locate and disconnect all disused drain connections. Permanently seal within the

site. 35 DRAINS IN USE - General: Protect drains and fittings still in use and keep free of debris at all times. - Damage: Make good any damage arising from demolition work. Leave clean and in working

order at completion. 40 BYPASS CONNECTIONS - General: Provide as necessary to maintain continuity of services to occupied areas of the

same and adjoining properties. - Notice: Give adequate notice to occupiers if shutdown is necessary. 45 SERVICES WHICH ARE TO REMAIN - Damage: Give notice and notify the service authority or owner of any damage arising from the

execution of the Works. - Repairs: To the satisfaction of the CA and service authority or owner. 50 WORKMANSHIP - Standard: Demolish structures in accordance with BS 6187. - Operatives: Appropriately skilled and experienced for the type of work and holding or be

training to obtain relevant CITB Certificates of Competence. - Site staff responsible for supervision and control of work: Experienced in the assessment of

risks involved and methods of demolition to be used.

Page 4: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/2

C20 DEMOLITION (Continued) 55 SITE HAZARDS - Fire or explosion caused by gas or vapour: Prevent. - Dust: Reduce by periodically spraying with water. - Site operatives and general public: Protect from vibration, dangerous fumes and dust arising

during the course of the Works. 60 ADJOINING PROPERTY - Temporary support and protection: Provide at each stage. - Damage: Prevent. Promptly repair. Leave no unnecessary or unstable projections. - Support to foundations: Do not disturb. - Defects: Report any defects exposed or becoming apparent. 65 STRUCTURES TO BE RETAINED - Parts which are to be kept in place: Protect. - Extent of work: Cut away and strip out the minimum necessary. - Debris: Prevent from overloading any part of the structure which is not to be demolished. 70 PARTLY DEMOLISHED STRUCTURES - General: Leave partly in a stable condition, with adequate temporary support at each stage to

prevent risk of uncontrolled collapse. - Debris: Prevent from overloading scaffolding platforms. - Unauthorised persons: Prevent access. Keep safe outside working hours. 71 DANGEROUS OPENINGS - General: Illuminate and protect as necessary. 76 ASBESTOS BASED MATERIALS - Discovery: Give note immediately of any suspected asbestos based materials discovered.

Avoid disturbing such materials and submit details of methods for safe removal. 85 SITE CONDITION AT COMPLETION - Debris: Clear away and leave the site tidy on completion. 86 SITE LEVELS AT COMPLETION - Debris: Grade the site to follow the levels of adjacent areas. 90 CONTRACTOR’S PROPERTY - Components and materials arising from the demolition work: Property of the Contractor

except where otherwise provided. Remove from site as work proceeds. 95 RECYCLED MATERIALS - Materials arising from demolition work: May be recycled or reused elsewhere in the project,

subject to compliance with the appropriate specification.

Page 5: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/3

C90 ALTERATIONS - SPOT ITEMS To be read with Preliminaries/General conditions.

GENERALLY

110 APPLICABILITY: The requirements of this section apply to all alteration work to existing buildings given as spot items in various parts of the schedules.

120 QUALITY OF WORK in spot items to be as described in the relevant other sections of the

specification. 150 SUPPORT existing structure as necessary during cutting of new openings or replacement of

structural parts. Do not remove supports until new work is strong enough to support the existing structure.

160 PROTECTION OF BUILDING INTERIORS: Protect building interiors exposed to weather

during course of alteration work with temporary weathertight enclosures of sufficient size to permit execution of new work and ability to withstand severe weather.

170 MAKING GOOD: Unless otherwise stated make good parts and/or finishes of existing

structure disturbed during alterations to match existing.

PRODUCTS/MATERIALS ARISING

210 OWNERSHIP: Products and materials arising from the alteration work are to become the

property of the Contractor except where otherwise stated. Remove from site as work proceeds.

220 OWNERSHIP: The following are to remain the property of the Employer. Carefully lift to take

down and store on site where directed. Protect until removed by Employer or end of Contract:

As itemised in the Schedule of Works. 220 HARDCORE:Brick rubble or other hard materials arising from the work may be re-used as

hardcore, subject to compliance with specification. 230 INFECTED TIMBER: Where instructed, remove timber affected by fungal/insect attack from

the building in a way which will minimise the risk of infecting other parts of the building, and destroy as soon as possible.

280 BURNING ON SITE of materials arising from the work will not be permitted.

Page 6: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/4

G20 CARPENTRY/ TIMBER FRAMING/ FIRST FIXING 40 MOISTURE CONTENT - Moisture content of wood and wood based products at time of installation: Not more than: - Covered in generally unheated spaces: 24%. - Covered in generally heated spaces: 20%. - Internal in continuously heated spaces: 20%. 41 BOLT/ SCREW ASSEMBLIES GENERALLY - Designation: As specified. - Size: As specified. - Coating applied by manufacturer: ______ . - Nuts and washers: Material grade and finish to suit bolts - Washer dimensions: Diameter/ side length of washers in contact with timber faces to be

minimum 3 times bolt diameter, with a thickness not less than 0.25 times bolt diameter. 43 BOLTED JOINTS - Bolt spacings (minimum): To BS 5268-2, table 81. - Holes for bolts: Located accurately and drilled to diameters as close as practical to the

nominal bolt diameter and not more than 2 mm larger. - Washers: Placed under bolt heads and nuts that would otherwise bear directly on timber. Use

spring washers in locations which will be hidden or inaccessible. - Bolt tightening: So that washers just bite the surface of the timber. Ensure that at least one

complete thread protrudes from the nut. - Checking: At agreed regular intervals. Tighten as necessary. 45 FRAMING ANCHORS - Manufacturer: As specified. - Product reference: As specified. - Material/ finish: Stainless steel. - Fasteners: Galvanized or sherardized square twist nails. - Size: Not less than size recommended by anchor manufacturer. - Fixing: Secure using not less than the number of nails recommended by anchor manufacturer. 50 ADDITIONAL SUPPORTS - Provision: Position and fix additional studs, noggings and/ or battens to support edges of

sheet materials, and wall/ floor/ ceiling mounted appliances, fixtures, etc. shown on drawings. - Material properties: Timber to be of adequate size and have the same treatment as adjacent

timber supports.

Page 7: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/5

L20 DOORS/ SHUTTERS/ HATCHES 10 TIMBER PROCUREMENT - Timber (including timber for wood based products): Obtained from well managed forests and/

or plantations in accordance with: - The laws governing forest management in the producer country or countries. - International agreements such as the Convention on International Trade in Endangered

Species of wild fauna and flora (CITES). - Documentation: Provide either: - Documentary evidence (which has been or can be independently verified) regarding the

provenance of all timber supplied. - Evidence that suppliers have adopted and are implementing a formal environmental

purchasing policy for timber and wood based products. 20 WOOD FLUSH DOORS GENERALLY - Manufacturer: Jeld Wen. - Product reference: As specified. - Facings: Veneer to be confirmed. - Lippings: Hardwood. - Preservative treatment: Required. - Finish as delivered: Veneered. - Glazing details: As specified. - Beading: As specified. 55 DOORSETS GENERALLY - Finish as delivered: As specified. - Glazing details: As specified. - Ironmongery: As specified. - Perimeter seals: Intumescent strips. - Fixing: Screwed. - Spacing of fixings (frames not predrilled): Maximum 150 mm from ends of each jamb and

at 600 mm maximum centres. 70 FIRE RESISTANCE - Requirement: Specified performance to be the minimum period attained when tested for

integrity in accordance with BS 476-22, BS EN 1634-1 or BS EN 1634-3. 75 FIRE RESISTING/ SMOKE CONTROL DOORS/ DOORSETS - Gaps between frames and supporting construction: Filled as necessary in accordance with

door/ doorset manufacturer's instructions. 80 SEALANT JOINTS - Sealant: - Manufacturer: Dow Corning. Product reference: Polysulphide mastic. - Colour: To be confirmed. - Application: As section Z22 to prepared joints. Triangular fillets finished to a flat or slightly

convex profile. 85 FIXING IRONMONGERY GENERALLY - Fasteners: Supplied by ironmongery manufacturer. - Finish/ Corrosion resistance: To match ironmongery. - Holes for components: No larger than required for satisfactory fit/ operation. - Adjacent surfaces: Undamaged. - Moving parts: Adjusted, lubricated and functioning correctly at completion.

Page 8: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/6

L40 GENERAL GLAZING 10 WORKMANSHIP GENERALLY - Glazing: - Generally: To BS 6262. - Integrity: Wind and watertight under all conditions. Make full allowance for deflections and

other movements. - Glass: - Standards: Generally to BS 952 and to the relevant parts of: BS EN 572 for basic soda lime silicate glass. BS EN 1096 for coated glass. BS EN 12150 for thermally toughened soda lime silicate glass. BS EN ISO 12543 for laminated glass. - Quality: Free from scratches, bubbles and other defects. - Dimensional tolerances: Panes/ sheets to be accurately sized. - Material compatibility: Glass/ plastics, surround materials, sealers primers and paints/ clear

finishes to be compatible. Comply with glazing/ sealant manufacturer’s recommendations. 20 REMOVAL OF GLASS/ PLASTICS FOR REUSE - Existing glass/ plastics, glazing compound, beads, etc: Remove carefully, avoiding damage to

frame, to leave clean, smooth rebates free from obstructions and debris. Clean glazing, beads and other components that are to be reused.

- Deterioration of frame/ surround: Submit report on defects revealed by removal of glazing. - Affected areas: Do not reglaze until instructed. 30 PREPARATION - Surrounds, rebates, grooves and beads: Clean and prepare before installing glazing. 55 BEAD FIXED INSULATING GLASS UNITS TO NEW WINDOWS AND DOORS - Pane material: ______ . - Inner pane: ______ . - Outer pane: ______ . - Spacer: ______ . - Perimeter taping: Do not use. - Surround/ bead: ______ . - Preparation: ______ . - Bead location: ______ . - Bead fixing: ______ . - Glazing system: ______ . - Glazing installation: - Insulating unit: Located centrally in surround using setting and location blocks. - Gaskets and beads: Installed as recommended by frame manufacturer. - Gasket fit at corners: Tight, without gaps. - Drainage and ventilation holes: Unobstructed.

All as specified

Page 9: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/7

M20 PLASTERED/ RENDERED/ ROUGHCAST COATINGS 30 LIGHTWEIGHT GYPSUM PLASTER GENERALLY: - Background/ Backing: To existing and new walls. - Preparation: Bonding agent if required. - Plaster manufacturer: Gypsum. - Undercoats: To BS 1191-2. - Thickness (excluding dubbing out): 13mm. - Final coat: Finish plaster to BS 1191-1, class B. - Product reference: Thistle finish. - Thickness: 2 mm. - Finish: Smooth. 50 GYPSUM PLASTER SKIM ON PLASTERBOARD - Background: Plasterboard. - Plasterboard manufacturer: Gypsum. - Product reference: Foil backed. - Plaster: Board finish plaster to BS 1191-1, class B. - Manufacturer: Gypsum. Product reference: Skim coat. - Thickness: 3mm. - Finish: Smooth. 67 COLD WEATHER - Internal work: Take precautions to prevent damage to internal work when air temperature is

below 3°C. - External work: Avoid when air temperature is below 5°C and falling or below 3°C and rising. 71 SUITABILITY OF BACKGROUNDS - General: Suitable to receive coatings. Sound, free from contamination and loose areas. 74 EXISTING DAMP AFFECTED PLASTER/ RENDER - Plaster affected by rising damp: Remove to a height of 300 mm above highest point reached

by damp or 1 m above dpc, whichever is higher. - Perished and salt contaminated masonry: - Mortar joints: Rake out. - Masonry units: Seek instructions. - Drying out backgrounds: Establish drying conditions. 76 REMOVING DEFECTIVE EXISTING PLASTER - Plaster for removal: Loose, hollow, soft, friable, badly cracked, affected by efflorescence or

otherwise damaged. - Stained plaster: Seek instructions. - Removing plaster: Cut back to a square, sound edge. 80 FIXING PLASTERBOARD BACKINGS - Additional framing supports: - Fixtures, fittings and service outlets: To suit fixings. - Board edges and perimeters: To suit type and performance of board. - Joints: - Joint widths (maximum): 3 mm. - End joints: Stagger between rows. - Two layer boarding: Stagger joints between layers. - Joint reinforcement: To joints and angles except where coincident with metal beads.

Page 10: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/8

M20 PLASTERED/ RENDERED/ ROUGHCAST COATINGS (Continued) 82 BEADS/ STOPS - Location: External angles and stop ends. - Materials: - External render: Stainless steel. - Internal plaster/ render: Galvanized steel. - Fixing: Secure and true to line and level. - External render: Fix mechanically. 87 APPLICATION OF COATINGS - General: Apply coatings firmly and achieve good adhesion. - Appearance of finished surfaces: Even and consistent. Free from rippling, hollows, ridges,

cracks and crazing. - Accuracy: Finish to a true plane with walls and reveals plumb and square. - Drying out: Prevent excessively rapid or localized drying out. - Keying undercoats: Provide key for next coat by cross scratching (plaster coatings) and

combing (render coatings). Do not penetrate undercoat.

Page 11: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/9

M60 PAINTING/ CLEAR FINISHING 10 EMULSION PAINT TO INTERNAL WALLS TO AREA OF WORKS - Manufacturer: Dulux - Product reference: Dulux Diamond Matt Silk Emulsion - Surfaces: Internal existing and new surfaces - Preparation: Prime - Initial coats: Mist - Number of coats: 1 No - Undercoats: Full - Number of coats: 1 No - Finishing coats: Full - Number of coats: 1 No 12 GLOSS PAINT TO INTERNAL JOINERY AND MELATWORK TO AREA OF WORKS - Manufacturer: Dulux - Product reference: Dulux Trade - Surfaces: Internal joinery - Preparation: Prime - Undercoats: Full - Number of coats: 2 No - Finishing coats: Full - Number of coats: 1 No 30 PREPARATION GENERALLY - Standard: In accordance with BS 6150. - Risk assessment and method statement for hazardous materials: Prepare for operations,

disposal of waste, containment, and reoccupation, and obtain approval before commencing work.

- Preparation materials: Types recommended by their manufacturers and the coating manufacturer for the situation and surfaces being prepared.

- Substrates: Sufficiently dry in depth to suit coating. - Efflorescence salts, dirt, grease and oil: Remove. - Surface irregularities: Provide smooth finish. - Organic growths and infected coatings: - Remove with assistance of biocidal solution. - Apply residual effect biocidal solution to inhibit regrowth. - Joints, cracks, holes and other depressions: Fill with stoppers/ fillers. Provide smooth finish. - Dust, particles and residues from preparation: Remove and dispose of safely. - Doors, opening windows and other moving parts: - Ease, if necessary, before coating. - Prime resulting bare areas. 32 PREVIOUSLY COATED SURFACES GENERALLY - Preparation: In accordance with BS 6150, clause 11.5. - Contaminated or hazardous surfaces: Give notice of: - Coatings suspected of containing lead. - Substrates suspected of containing asbestos. - Significant rot, corrosion or other degradation of substrates. - Risk assessment and method statement for hazardous materials: Prepare for operations,

disposal of waste, containment and reoccupation, and obtain approval before commencing work.

- Removing coatings: Do not damage substrate and adjacent surfaces or adversely affect subsequent coatings.

- Loose, flaking or otherwise defective areas: Carefully remove to a firm edge. - Alkali affected coatings: Completely remove. - Retained coatings: - Thoroughly clean. - Gloss coated surfaces: Provide key. - Partly removed coatings: Apply additional preparatory coats. - Completely stripped surfaces: Prepare as for uncoated surfaces.

Page 12: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/10

M60 PAINTING/ CLEAR FINISHING (Continued) 35 FIXTURES AND FITTINGS - Risk assessment and method statement for hazardous materials: Prepare for operations,

disposal of waste, containment, and reoccupation, and obtain approval before commencing work.

- Removal: Before commencing work remove: All redundant brackets, screws, nails, fixtures and fittings complete.

- Replacement: Refurbish as necessary, refit when coating is dry. 37 WOOD PREPARATION - General: Provide smooth, even finish with lightly rounded arrises. - Degraded or weathered surface wood: Take back surface to provide suitable substrate. - Degraded substrate wood: Repair with sound material of same species. - Heads of fasteners: Countersink sufficient to hold stoppers/ fillers. - Resinous areas and knots: Apply two coats of knotting. - Defective primer: Take back to bare wood and reprime. 43 PLASTER PREPARATION - Nibs, trowel marks and plaster splashes: Scrape off. - Overtrowelled ‘polished’ areas: Provide suitable key.

Page 13: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/11

N10 GENERAL FIXTURES/ FURNISHINGS/ EQUIPMENT To be read with Preliminaries/ General conditions.

Page 14: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/12

P12 FIRE STOPPING SYSTEMS GENERAL 10 FIRE STOPPING GENERALLY - Joint filler: Fire resisting - Size or thickness: To suit application - Sealant: Fire resisting skin - Colour: White PRODUCTS 36 INTUMESCENT FOAMS - Manufacturer: Contractor’s choice - Product reference: To achieve 1 hour fire resistance EXECUTION 62 EXECUTION GENERALLY - Gaps: Seal gaps between building elements and services, to provide fire resistance and resist

the passage of smoke. - Adjacent surfaces: Prevent overrun of sealant or mortar on to finished surfaces. 63 INSTALLING FIRE STOP LAMINATES - Strip width: Wider than joint width. - Fitting of strips: Compress strips and fit into joint, so that as they decompress the strips

wedge themselves in the void. - Joints: - Ends of strips: Fit intumescent ‘end piece’ at the end of joints. - Joints in strips: Fit two intumescent ‘end pieces’ at each butt joint. 64 APPLYING INTUMESCENT FOAM - New joints: Remove builder’s debris, mortar droppings, grease, and the like. - Old joints: Clean and remove existing sealant from the joint. - Priming: Lightly moisten substrate with water. - Application: Fill joint to approximately half its depth, allowing foam to expand to face of joint. - Trimming: Do not trim or cut the face of the cured foam. 66 INSTALLING BATTS - Installing batts: Fit tight into void between the floor or wall and the penetrating services. - Face of batts: Flush with the surface of wall, floor or soffit. - Joints: Closed - Gaps between services and bulkhead: Seal with fire resisting sealant. COMPLETION 91 CLEANING - Masking tapes: Remove. - Cleaning: Clean off splashes and droppings. Wipe down finishes. 92 INSPECTION - Notice for inspection (minimum): 2 days.

Page 15: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/13

P20 UNFRAMED ISOLATED TRIMS/ SKIRTINGS/ SUNDRY ITEMS 10 SOFTWOOD JOINERY GENERALLY - Quality of wood and fixing: To BS 1186-3. - Species: European redwood. - Class: C2. - Moisture content at time of fixing: 12 to 19%. - Preservative treatment: Required. - Fire rating: Class 1. - Profile: As specified. - Finished size: As specified. - Finish as delivered: Primed. - Fixing: Screwed. 35 MEDIUM DENSITY FIBREBOARD GENERALLY - Manufacturer: Contractor’s choice. - Standard: To BS EN 622-5. - Type: MDF. - Formaldehyde class: To BS EN 622-1, Class E1. - Fire rating: Class 0. - Thickness: As specified. - Edges: Chamfered. - Finish: Prepared. - Support/ Fixing: As specified. 40 PLYWOOD GENERALLY - Face ply species: wbp - Appearance class to BS EN 635: Beech. - Bond quality to BS EN 314-2: P1. - Thickness: As specified. - Edges: As specified. - Support/ Fixing: As specified. 80 INSTALLATION GENERALLY - Joinery workmanship: As section Z10. - Metal workmanship: As section Z11. - Methods of fixing and fasteners: As section Z20. - Straight runs: To be in one piece, or in long lengths with as few joints as possible. - Running joints: Location and method of forming to be agreed where not detailed. - Joints at angles: Mitred. - Position and level: To be agreed where not detailed.

Page 16: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/14

P21 DOOR/ WINDOW IRONMONGERY All as specified.

Page 17: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/15

P31 HOLES, CHASES, COVERS AND SUPPORTS FOR SERVICES 10 HOLES, RECESSES AND CHASES IN MASONRY - Locations: To maintain integrity of strength, stability and sound resistance of construction. - Sizes: Minimum needed to accommodate services. - Holes (maximum): 300 x 300 mm. - Walls of hollow or cellular blocks: Do not chase. - Walls of other materials: - Vertical chases: No deeper than one third of single leaf thickness, excluding finishes. - Horizontal or raking chases: No longer than 1 m. No deeper than one sixth of the single

leaf thickness, excluding finishes. - Chases and recesses: Do not set back to back. Offset by a clear distance at least equal to the

wall thickness. - Cutting: Do not cut until mortar is fully set. Cut carefully and neatly. Avoid spalling, cracking

and other damage to surrounding structure. 20 NOTCHES AND HOLES IN STRUCTURAL TIMBER - General: Avoid if possible. - Sizes: Minimum needed to accommodate services. - Position: Do not locate near knots or other defects. - Notches and holes in same joist: Minimum 100 mm apart horizontally. - Notches in joists: Locate at top. Form by sawing down to a drilled hole. - Depth (maximum): 0.125 x joist depth. - Distance from supports: Between 0.07 and 0.25 x span. - Holes in joists: Locate on neutral axis. - Diameter (maximum): 0.25 x joist depth. - Centres (minimum): 3 x diameter of largest hole. - Distance from supports: Between 0.25 and 0.4 of span. - Notches in roof rafters, struts and truss members: Not permitted. - Holes in struts and columns: Locate on neutral axis. - Diameter (maximum): 0.25 x minimum width of member. - Centres (minimum): 3 x diameter of largest hole. - Distance from ends: Between 0.25 and 0.4 of span. 30 PIPE SLEEVES - Material: Match pipeline. - Sleeves: Extend through full thickness of wall or floor. Position accurately. - Clearance around service (maximum): 20 mm or diameter of service, whichever is the

lesser. - Installation: Bed solid.

Page 18: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/16

V90 ELECTRICAL SYSTEMS - DOMESTIC GENERAL 05 LOW VOLTAGE SUPPLY - New electrical system to be an extension off school’s existing system and all as specified in

the Schedule of Works. 20 GENERAL DESIGN - Standards: To BS 7671 and the requirements of the electricity distributor. - Design: Complete the design and detailing of the electrical installation. - Design information: Submit calculations, manufacturer's literature and drawings showing

equipment positions and routes. 21 DESIGN OF LOW VOLTAGE INCOMING SUPPLY - Capacity: Determine the anticipated maximum demand of the installation. - Establishing the supply: Manage and liaise with the electricity distributor to establish an

incoming electricity supply. - Electricity supplier: Refer to school. - Liaise with the electricity supplier, complete an application for supply of electricity and

manage installation of metering equipment. - Incoming earthing arrangement: Establish with the electricity distributor. - Location: Coordinate the location of the incoming supply and establish the spatial

requirements for the electricity distributor's equipment and metering. 24 GENERAL LIGHTING DESIGN - Purpose: As detailed. - Design: To CIBSE ‘Code for lighting’. - Room: As detailed. - Illuminance level (maintained average): 500 lux in classrooms/offices and 300 lux within

corridors. - Controls: As detailed. - Maintenance: Submit proposals for the maintenance/ relamping regime. 26 DESIGN AND LIGHTING CALCULATIONS - Design: Complete the design of the following lighting systems: Where referred to in the

Schedule. - Proposals: Submit drawings, technical information, calculations and manufacturers’ literature. - Lighting calculations: - Type: Computer generated point calculations. - Submit the following: - Luminaire layout drawings. - Luminaire photometric data including flux fraction ratios and polar intensity curves. - Lamp technical information. - Maintenance factor calculations, including proposals for luminaire maintenance and lamp

replacement. - Isolux contour plots for the working plane. - Schedule of design and calculated maintained average illuminance values. - Schedule of design and calculated uniformity values. 27 SMALL POWER DESIGN - Purpose: General teaching. - Small power outlets: Provide to serve the building and its equipment. - Room Where detailed. - Outlets: As Schedule. - Fixed equipment: Provide supplies.

Page 19: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/17

V90 ELECTRICAL SYSTEMS - DOMESTIC (Continued) 28 DESIGN OF PHOTOVOLTAIC SYSTEM - Refer to Eco First Specification - Standards: In accordance with DTI report URN 06/1972 and ENA G59/1 or G83/1-1. - Output: Determine a suitable rating for the installation. - Proposals: Submit drawings showing equipment positions, cable routes, technical information

and calculations. - Evidence of agreement with Electricity Distributor: Submit. - General: Manage and liaise with the Electricity Distributor. PRODUCTS 30 PRODUCTS GENERALLY - Standard: To BS 7671. - CE Marking: Required. 32 DISTRIBUTION BOARDS AND CONSUMER UNITS - Standards: To BS EN 60439-3 and ASTA certified. - Manufacturer: Contractor’s choice. - Number of ways: Determine. - Spare capacity: Required. 35 CONDUIT - Standard: To BS EN 61386-1. - Type: Suitable for location and use. 37 STEEL CONDUIT AND FITTINGS GENERALLY - Standards: To BS 4568-1 or BS EN 61386-1 and BS EN 61386-21. - Manufacturer: Contractor’s choice. 38 PVC CONDUIT AND FITTINGS GENERALLY - Standards: To BS 4607-5 or BS EN 61386-1 and BS EN 61386-21. - Manufacturer: Contractor’s choice. 39 CABLES - Standard: To BS 7671. - Approval: British Approvals Service for Cables (BASEC) certified. - Cable sizes not stated: Submit proposals and calculations. 40 PROTECTIVE CONDUCTORS - Type: Cable conductors with yellow/ green sheath. 45 LUMINAIRES GENERALLY - Standards: To BS EN 60598-1 and BS EN 55015. - All as detailed by Coco Lighting, telephone 01376 331515. 47 LAMPS GENERALLY - Standards: - Compact fluorescent lamps: To BS EN 60901 and BS EN 61199. - High pressure mercury lamps: To BS EN 60188 and BS EN 62035. - High pressure sodium lamps: To BS EN 62035. - Metal halide lamps: To BS EN 62035. - Tubular fluorescent lamps: Single-capped lamps: To BS EN 60901 and BS EN 61199. Double-capped lamps: To BS EN 60081 and BS EN 61195. - Tungsten halogen lamps: To BS EN 60432-2 and BS EN 60357. - Manufacturer: As detailed by Coco Lighting, telephone 01376 331515. - Lamps of the same type and rating: Same manufacturer.

Page 20: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/18

V90 ELECTRICAL SYSTEMS - DOMESTIC (Continued) 52 PHOTOVOLTAIC SYSTEM - Standards: - General: To BS 7671. - PV modules: To BS EN 61215 or BS EN 61646. - Junction boxes and switchgear assemblies: To BS EN 60439-1. - Manufacturer: As detailed by Eco First, telephone 0845 2575064. EXECUTION 60 GENERAL EXECUTION - Standards: To BS 7671. 61 INSTALLING PHOTOVOLTAIC SYSTEMS - As detailed by Eco First, telephone 0845 2575064. 63 INSTALLING CONDUIT AND FITTINGS - Fixing: Fix securely. Fix boxes independently of conduit. - Drainage outlets: Locate at lowest points in conduit installed externally, and where

condensation may occur. - Location: Position vertically and horizontally in line with equipment served, and parallel with

building lines. Locate where accessible. - Jointing: - Number of joints: Minimize. - Lengths of conduit: Maximize. - Cut ends: Remove burrs, and plug during building works. - Movement joints in structure: Manufactured expansion coupling. - Threaded steel conduits: Tightly screw to ensure electrical continuity, with no thread

showing. - Conduit connections to boxes and items of equipment, other than those with threaded

entries: Earthing coupling/ male brass bush and protective conductor. - Changes of direction: Site machine-formed bends, junction boxes and proprietary

components. Do not use elbows or tees. Alternatively, use conduit boxes. - Connections to boxes, trunking, equipment and accessories: Screwed couplings, adaptors,

connectors and glands, with rubber bushes at open ends. 64 INSTALLING TRUNKING - Positioning: Accurate with respect to equipment served, and parallel with other services and,

where relevant, floor level and other building lines. - Access: Provide space encompassing cable trunking to permit access for installing and

maintaining cables. - Jointing: - Number of joints: Minimize. - Lengths of trunking: Maximize. - Steel systems: Mechanical couplings. Do not weld. Fit a copper link at each joint to ensure

electrical continuity. - Movement: Fix securely. Restrain floor mounted systems during screeding. - Junctions and changes of direction: Proprietary jointing units. - Cable entries: Fit grommets, bushes or liners. - Internal fire barriers: Provide to maintain integrity of fire compartment. - Protection: Fit temporary blanking plates. Prevent ingress of screed and other extraneous

materials. - Service outlet units: Fit when cables are installed.

Page 21: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/19

V90 ELECTRICAL SYSTEMS - DOMESTIC (Continued) 66 CABLE ROUTES - Cables generally: Conceal wherever possible. - Concealed cable runs to wall switches and outlets: Align vertically with the accessory. - Exposed cable runs: Submit proposals. - Orientation: Straight, vertical and/ or horizontal and parallel to walls. - Distance from other services running parallel: 150 mm minimum. - Heating pipes: Position cables below. 68 INSTALLING ELECTRICAL ACCESSORIES AND EQUIPMENT - Location: To be confirmed. - Arrangement: Coordinate with other wall or ceiling mounted equipment. - Positioning: Accurately and square to vertical and horizontal axes. - Alignment: Align adjacent accessories on the same vertical or horizontal axis. - Mounting: Wall mounted. - Mounting heights (finished floor level to underside of equipment or accessory): To be agreed. 70 INSTALLING FINAL CONNECTIONS - Size: Determine. - Cable: Heat resisting white flex. - Length: Allow for equipment removal and maintenance. 72 INSTALLING LUMINAIRES - Location: As detailed. - Supports: Adequate for weight of luminaire. - Locations: Submit proposals. 74 LABELLING - Identification and notices: - Standards: To BS 5499-5 and BS 5378-2. - Equipment: Label when a voltage exceeding 230 V is present. - Distribution boards and consumer units: Card circuit chart within a reusable clear plastic

cover. Fit to the inside of each unit. Include typed information identifying the outgoing circuit references, their device rating, cable type, size, circuit location and details. Label each outgoing way corresponding to the circuit chart.

- Sub-main cables: Label at both ends, with proprietary cable marker sleeves. 76 ENGRAVING - Metal and plastic accessories: Engrave, indicating their purpose. - Emergency lighting test key switches: Describe their function. - Multigang light switches: Describe the luminaire arrangement. 78 FINAL FIX - Accessory faceplates, luminaires and other equipment: Fit after completion of building

painting. 80 CLEANING - Electrical equipment: Clean immediately before handover. - Equipment not supplied but installed under the electrical works: Clean immediately before

handover.

Page 22: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/20

V90 ELECTRICAL SYSTEMS - DOMESTIC (Continued) COMPLETION 95 INSPECTION AND TESTING GENERALLY - Standard: To BS 7671. - Notice before commencing tests (minimum): 24 hours. - Labels and signs: Fix securely before system is tested. - Inspection and completion certificates: Submit. - Number of copies: 2. 96 TESTING AND COMMISSIONING OF PV SYSTEM - Standards: In accordance with ENA G59/1 or ENA G83/1-1. - Low carbon buildings programme completion certificate: Submit. 99 MAINTENANCE - Servicing and maintenance: Undertake. - Duration: 1 year.

Page 23: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/21

Z10 PURPOSE MADE JOINERY 10 FABRICATION - Standard: To BS 1186-2. - Sections: Accurate in profile and length, and free from twist and bowing. Formed out of solid

unless shown otherwise. - Machined surfaces: Smooth and free from tearing, wooliness, chip bruising and other

machining defects. - Joints: Tight and close fitting. - Assembled components: Rigid. Free from distortion. - Screws: Provide pilot holes. Heads of countersunk screws sunk at least 2 mm below surfaces

visible in completed work. - Adhesives: Compatible with wood preservatives applied and end uses of timber. 20 CROSS SECTION DIMENSIONS OF TIMBER - General: Dimensions on drawings are finished sizes. - Maximum permitted deviations from finished sizes: - Softwood sections: To BS EN 1313-1. - Hardwood sections: To BS EN 1313-2. 30 PRESERVATIVE TREATED WOOD - Cutting and machining: Completed as far as possible before treatment. - Extensively processed timber: Retreat timber sawn lengthways, thicknessed, planed,

ploughed, etc. - Surfaces exposed by minor cutting and/ or drilling: Treat as recommended by main treatment

solution manufacturer. 40 MOISTURE CONTENT - Wood and wood based products: Maintained within range specified for the component during

manufacture and storage. 50 FINISHING - Surfaces: Smooth, even and suitable to receive finishes. - Arrises: Eased unless shown otherwise on drawings. - End grain in external components: Sealed with primer or sealer as section M60 and allowed

to dry before assembly.

Page 24: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/22

Z20 FIXINGS AND ADHESIVES 10 FIXINGS AND FASTENERS GENERALLY - Integrity of supported components: Select types, sizes, quantities and spacings of fixings,

fasteners and packings to retain supported components without distortion or loss of support. - Components, substrates, fixings and fasteners of dissimilar metals: Isolate with washers or

sleeves to avoid bimetallic corrosion. - General usage: To recommendations of fastener manufacturers and/ or manufacturers of

components, products or materials fixed and fixed to. - Fixings: To be in straight lines, at regular centres. 25 FASTENER DURABILITY - Materials: To have: - Bimetallic corrosion resistance appropriate to items being fixed. - Atmospheric corrosion resistance appropriate to fixing location. - Appearance: Submit samples on request. 30 FIXINGS THROUGH FINISHES - Penetration of fasteners and plugs into substrate: To achieve a secure fixing. 35 PACKINGS - Materials: Noncompressible, corrosion proof. - Area of packings: Sufficient to transfer loads. 40 CRAMP FIXINGS - Fasteners: Fix cramps to frames with screws of same material as cramps. - Fixings in masonry work: Fully bed in mortar. 50 PELLETED COUNTERSUNK SCREW FIXINGS - Finished level of countersunk screw heads: Minimum 6 mm below timber surface. - Pellets: Cut from matching timber, grain matched, glued in to full depth of hole. - Finished level of pellets: Flush with surface. 55 PLUGGED COUNTERSUNK SCREW FIXING - Finished level of countersunk screw heads: Minimum 6 mm below timber surface. - Plugs: Glue in to full depth of hole. - Finished level of plugs: Projecting above surface. 60 APPLYING ADHESIVES - Surfaces: Clean. Regularity and texture to suit bonding and gap filling characteristics of

adhesive. - Support and clamping during setting: Provide as necessary. Do not mark surfaces of or distort

components being fixed. - Finished adhesive joints: Fully bonded. Free of surplus adhesive.

Page 25: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship

3271 2/23

Z22 SEALANTS PRODUCTS 31 JOINTS GENERALLY - Primer, backing strip, bond breaker: Types recommended by sealant manufacturer. EXECUTION 61 SUITABILITY OF JOINTS - Presealing checks: - Joint dimensions: Within limits specified for the sealant. - Substrate quality: Surfaces regular, undamaged and stable. 62 PREPARING JOINTS - Surfaces to which sealant must adhere: - Remove temporary coatings, tapes, loosely adhering material, dust, oil, grease, surface

water and contaminants that may affect bond. - Clean using materials and methods recommended by sealant manufacturer. - Vulnerable surfaces adjacent to joints: Mask to prevent staining or smearing with primer or

sealant. - Backing strip and/ or bond breaker installation: Insert into joint to correct depth, without

stretching or twisting, leaving no gaps. - Protection: Keep joints clean and protect from damage until sealant is applied. 63 APPLYING SEALANTS - Substrate: Dry (unless recommended otherwise) and unaffected by frost, ice or snow. - Environmental conditions: Do not dry or raise temperature of joints by heating. - Sealant application: Fill joints completely and neatly, ensuring firm adhesion to substrates. - Sealant profiles: - Butt and lap joints: Slightly concave. - Fillet joints: Flat or slightly convex. - Protection: Protect finished joints from contamination or damage until sealant has cured.

Page 26: 2.00 MATERIALS AND WORKMANSHIPfastracktenders.com/wp-content/uploads/2019/11/tm17... · 2019-11-11 · Materials and Workmanship 3271 CONTENTS C20 Demolition C90 Alterations - spot

Materials and Workmanship £ p

3271 2/24

MATERIALS AND WORKMANSHIP – GENERALLY Allow for anything in the materials, workmanship

and general clauses that is not included elsewhere in the pricing.

List below the items included:

TOTAL MATERIALS AND WORKMANSHIP TO SUMMARY

£