Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Copyright © 2021 Data Sync Engineering. All Rights Reserved. Designated trademarks and brands are the property of their respective owners.
Data Sync Engineering P.O. Box 539, 2 Footbridge Lane Blairstown, New Jersey 07825
TEL: (908) 362-6299
www.cdadapter.com
It's the rockin’ 50's and 60's all over again ...
The WB-HUBe is an SD (Secure Digital) memory card m usic player system for jukebox wallbox selectors. M ake selections on the wallbox and instantly your songs are played, one by one, in the order received. Same way as it was back in the 40's and into the 70's. Any numb er of the same wallbox models can be connected to a single port. Setting up is easy, create folders on your me mory card then save the wallbox song files in the f older, setup the input port to your wallbox type along wit h the folder number to play from and your ready to go.
The WB-HUBe has four wallbox input ports and each p ort can be setup for a different wallbox model type as well as a different folder to play from. Most wallb ox types only use a single port, but some, such as the Wurlitzer 5204 7-wire, 4851 4-wire and Seeburg "Dig ital Electronic Consolette", use more than one port .
The Random AutoPlay feature allows non-stop music p lay when all wallbox song selections have been play ed. Random selections will be played from any available folder number or from 1 to 10 user defined folder numbers. You can have up to 100 folders (00 to 99) with each having up to 100 songs (00 to 99) for Ran dom AutoPlay or directly select up to 10,000 songs from the wireless remote.
A 3.5mm to stereo RCA male cable provides the "line -out" signal for your external amplifier or you can plug in a Bluetooth Transmitter (TX) for Bluetooth supported speakers or amplifiers. The wireless remote control s the volume level.
The MP3 player supports all MPEG layer-III encoding s at fixed and variable bit-rates up to and includi ng 320 kbits/s. A 24-bit DAC provides 96dB of audio dynami c range. The player works with any FAT32 formatted SD Memory card which is compatible with Windows, Mac, Linux and other systems.
Remote control setup and description of the kit c ontents are at page 16
"WB-HUBe" FEATURES ♦ Bright 4-Digit LED Display for selecting, playing a nd setup ♦ Four Isolated Input Ports to support several wallbo x types ♦ Interval Timed Random AutoPlay from all or Selected Folders ♦ AutoPlay Preview Mode with Full Play action request ♦ Voltage Trip Input for Random or Sequential Song Se lections ♦ Line-Out Audio for Amplifier Input or Bluetooth TX Module ♦ Wireless Remote for Pause, Cancel, Volume, Select & Features ♦ J9 Auxiliary "Plug-Ins" provide expanded selection capabilities
Can also use a Micro SD card with Adapter
16.0
GB
16GB SD Memory Card Up to 3,200 song selections
using MP3 bitrate @192Kbps
USB 2.0 SD Reader
16GB SD Memory Card included, nothing else to buy !
Doc 022621
Page 2 © 2021 Data Sync Engineering
WB-HUBe Player System
Inside View FRONT PANEL LED INDICATORS
Green Selection Activity Red Player Activity
OPERATION
When power is applied to the player, the blue LED turns on for about 3-sec, turns off, then begins rapidly blinking during file indexing. When done, the LED remains off until a selection is made.
Blinks Error Description
1 Failed Hardware Test Diagnostics
2 FAT32 Filesystem Was Not Found
3 No Folders Found
4 No MP3 Files Found
If players blue LED rapidly flashing dim and green LED always on
No SD Memory Card in Socket or Defective SD Card
If players blue LED repeating 3-sec flash and green LED short flicker
Unsupported Memory Card Type or Defective SD Card
MP3 PLAYER FAULTS (Blue LED) Continuous Blinks - Pause - Blinks
The SD Memory Card Formatter can be Downloaded here
https://www.sdcard.org/downloads/formatter_4/
To format media above 32GB as FAT32 you can run "guiformat.exe" available here
www.ridgecrop.demon.co.uk/guiformat.htm
4-Digit LED Display
Blue LED Player Activity
Green LED SD Card Activity Red LED SD Card Power
Soft "Fade-In" Option Jumper On = Enabled Jumper Off = Disabled
PUSH-PUSH Style
SD Card Socket
Soft Fade-In starts song play at low volume then ramps up to the set level
To enter setup press & hold for 2-seconds
Rear View
1 2 3 4 5 6 7 8
2.1mm 9VDC Power
DB9F D-Sub J9 AUX
SETUP Push
Button
Wallboxes are connected to the WB-HUBe player using a pluggable, 3.81mm, screw type 8-wire Terminal Block Plug.
Each of the 2-wire input ports can support up to four of the same or mixed wallbox model types and each can be assigned to play from different song selection folders.
Supports wallbox model types having more than one signal wire connection. The J9 AUX connector provides expanded song selection capabilities using custom plug-in adapters.
One such adapter, the "J9AUX-01" on the following page, supports the Packard Pla-Mor "Butler" or the Wurlitzer 2140 "Frog Box".
See the wallbox wiring diagrams for details.
Power Indicator
LED
3.5mm Stereo Line-Out Audio • Amplifier AUX / Line Level Input • Plug-In Bluetooth transmitter (TX)
Page 3 © 2021 Data Sync Engineering
WB-HUBe Player System
Lamp: #51, 7.5V, .22A. 1.0 MSCP
Wurlitzer 2140 "Frog Box", 24 select
Terminal Board Connections for the "T" number wires
1 2
16
4 5 6 7
13 11
17 14
10
18 19
#19 is lamp power
Pin 25 is GND
Solder pin side
of DB25M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
14 T7
15 T17
16 T11
17 T4
18 T13
19
20
21
22
23 FREE
24
25 T1 / T16
T6 1
T18 2
T10 3
T5 4
T2 5
LED 6
7
T14 8
9
10
11
12
13
180Ω "LED" to Anode GND
Light up an LED
You can change the Song Folder Number (00-99) at setup Address Location 36.
The "LED" output signal can be used to light an LED when selection credits are available or you can drive a Solid State Relay to turn on the wallbox lamps to indicate ready to select. Except for the lamps, no other power is required for operation.
Electrical Wiring Diagram
DB25 Signal Description
6 LED Output at 5VDC when ready for a selection
8 Coin 10¢ Input, adds 1-9 credits (at SETUP 34)
18 Coin 5¢ Input, adds 1-9 credits (at SETUP 34)
23 FREE Set one credit, always to GND = Free Play
24 To GND Connect Pin 24 to 25 for 2140 / Frog mode
25 GND Two wires, T1 & T16, are for Frog Box GND
• Buttons are not latched, press & release to make selection.
• No selection is made if no credits are available (LED off).
• LED turns off during any button being pressed.
• Selection is processed after button is released.
• LED turns back on if more credits are available.
The J9AUX-01 is available as a separate purchase
The J9AUX-01 Plug-In Adapter allows support for eit her the Packard Pla-Mor "Butler" or the Wurlitzer 2140 "Frog Box" to your WB-HUBe Player System. The J9AUX-01 plugs directly into the player or you can use a DB9 M-F extension cable to position the adapt er at a distance of 100 feet. To enable the adapter operation, enter SETUP and ma ke the following changes ...
[34:nn] This setup is for the Wurlitzer 2140 "Frog Box" Sets up the coin switch credits. Of t he 2-digit entry, the first digit is for the 5¢ switch, next digit for 10¢ switch. For example, en try "12" adds 1 credit for 5¢ and 2 credits fo r 10¢. Swap digits or change values to match wallbox.
[35:01] Any non-zero setting enables J9AUX operati on.
[36:nn] nn is the 2-digit Song Folder Number 00-99
J9AU
X-01
Sol
der
pin
side
w
ired
to w
allb
ox
DB25M
2 Serial In
3 Serial Out
5 Ground
8 +5VDC
DB9 Pinout
Optional J9AUX-01 Wallbox Adapter
Solder pin side
of DB25M
Packard Pla-Mor 30-200 "Butler" Wallbox , 24 select
Electrical Wiring Diagram
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
14 T14
15 T15
16 T16
17 T17
18 T18
19 T19
20 T20
21 T21
22 T22
23 T23
24 T24
25 GND
T1 1
T2 2
T3 3
T4 4
T5 5
T6 6
T7 7
T8 8
T9 9
T10 10
T11 11
T12 12
T13 13
1 24
2
23
GND
Lam
p P
ower
These two screw terminals supply power to the lamps. Top lamp #55, title lamp #44. Requires about 6-Volts, 1A.
Wiring is a direct one-to-one from the DB25M connector pin number to the wallbox screw terminal number.
This allows multiple wallboxes to be daisy-chained together.
D-Sub pin 25 is the GND signal which is connected to the upper left screw terminal on the BUTLER wallbox.
When a coin is inserted, the selection number terminal is momentary connected to GND.
Except for the lamps, no other power is required to operate.
[36:nn] sets the song play Folder Number (nn= 00 to 99).
Page 4 © 2021 Data Sync Engineering
WB-HUBe Player System 4-Digit LED Display Operations
The WB-HUBe contains a 4-Digit LED Display that sho ws the current player activity. It is also used for Wireless Remote selections and during the System Configuration Setups.
When power is applied, four dashes will be displaye d. Song indexing can take up to several seconds.
Power Up Initializing
Player is Ready
A After indexing is completed, the Table Of Contents (TOC) is transferred to the player memory. During this transfer, the dashes will sequentially turn off.
When "PLAY" is displayed, it means the player is re ady and waiting for song selections. The front panel "PLAYER" LED (RED) flashes rapidly to indicate stopped.
Power Up
Flashing Error Displays (Press Remote CH- to continue)
Factory Test requires the selected folder at [14:xx] to have 100 selections,
numbered 00 to 99.
E0 E1 E2 Problem with Port 4 "Play Trip" setup
[04:xx] Trip type was not 28 or 29 [08:xx] Folder not found or was empty [12:xx] Number of tracks for each trip
Random AutoPlay Setup Error User Defined Folder Missing or Empty
Playing Songs
During song play, the first two digits are the curr ent Folder / Disc Number, the last two digits are the Song / Track Number. Also, the front panel "PLAYER" LED (R ED) flashes once per second while playing. If the wireless remote MUTE b utton is pressed, the song play is paused and the "PLAYER" LED is continuously on, press MUTE again to resume play. After the song has finished playing, the LED display goes blank an d the "PLAYER" LED flashes rapidly to indicate stopped.
If another song is waiting to be played, it is star ted and the song number is shown on the LED display. If no selection is available within 10 se conds, the LED display will show "PLAY".
8888 Folder # Song #
If the song was from a wallbox selection, this mess age will appear momentarily before the Folder & Song numbers are displayed. This is the ac tual wallbox song number. The example shows song number 26 as being played. Two wire wal lboxes show as 001-200, the Seeburg DEC wallbox displays the record numbers 100-179 ("A " side) and 200-279 ("B" side). 026
Four digit song selections can be directly entered from the wireless remote. The first two digits are the Folder / Disc Number and the next two digits are the Song / Track Number.
As digits are entered, they are shown in the low di git position of the LED display then moved up after each additional digit until all four digits are received. If you made a mistake before the last digit, you can cancel all digits b y pressing CH+. Remote selections are saved to play memory in the s ame way as wallbox selections. "Song Not Found" sel ections are ignored.
Remote Function Buttons
Cancel the current song play
Pause ON/OFF of the current song play. The front p anel "PLAYER" LED (RED) is always on during pause.
Turns AutoPlay ON (also used to clear incomplete remote selection digits or to switch from preview t o Full Play)
Turns AutoPlay OFF
Exit SETUP mode and re-boot (can be programmed to also enter SETUP mode)
Decrease or Increase the output volume level
Wireless Remote Control Operation
POWER
MUTE
CH+
CH−
INPUT
VOL− VOL+
Page 5 © 2021 Data Sync Engineering
WB-HUBe Player System Setting Up the WB-HUBe Configuration
Setup Mode is used to make changes to the operating configuration such as wallbox types, song folders and playing features. The SETUP addres s descriptions are outlined below.
To enter Setup, press & hold the SETUP button until the LED displays what's shown at the left.
On the LED display, the 1st 2 digits are the addres s location of the setting, the last 2 digits show the current setting value. To change a setting , simply enter a new two digit value 00-99.
Address "00" is not a setting but is used to cause a direct JUMP to any other address location. Pressing the SETUP button at any time forces the ad dress back to "00".
You can use the Remote to navigate through the sett ing list. CH+ to step upward to "00" or CH- to step downward to "47". To exit SETUP & reboo t, press the Remote INPUT button.
Setup Mode
SUMMARY OF SETUP ADDRESSES (Page 1)
Adr Res SETUP PARAMETER DESCRIPTIONS Adr Res SETUP PARAMETER DESCRIPTIONS
00: 00 (NOT A SETUP) 00-69= "JUMP to Adr" 70-99= F unction 24: 00 Non-zero allows direct SETUP from Remote INPUT butt on
01: 06 00-31, Port 1 Wallbox Type "Add 32 for 50Hz operat ion" 25: 99 00-98, 00= Cont AP, 01-98 = x1 min intervals, 99 = Off
02: 06 00-31, Port 2 Wallbox Type "Add 32 for 50Hz operat ion" 26: ## Number of previous selections for no-repeat AP chec king
03: 06 00-31, Port 3 Wallbox Type "Add 32 for 50Hz operat ion" 27: 00 WB no-repeat / WB duplicates / disable IR / Factory test
04: 06 00-31, Port 4 Wallbox Type "Add 32 for 50Hz operat ion" 28: 60 AutoPlay seconds multiplier (#25), 60= 1 Min, 01= 1 Sec
05: 01 00-99, Port 1 Starting Folder Number (if Seeburg DEC mode ) 29: 00 Zero= Quad WB mode, non zero= Seeburg DEC mode
06: 01 00-99, Port 2 Starting Folder Number 30: 00 Custom Wallbox setting "C2" and "C5" modifiers
07: 01 00-99, Port 3 Starting Folder Number 31: 00 <unassigned>
08: 01 00-99, Port 4 Starting Folder Number 32: 00 <unassigned>
09: 00 00-99, Port 1 Track Number Adder or Latched Offset 33: 00 <unassigned>
10: 00 00-99, Port 2 Track Number Adder or Latched Offset 34: 00 <AUX J9> Optional Setup Value (if required)
11: 00 00-99, Port 3 Track Number Adder or Latched Offset 35: 00 <AUX J9> Non-zero, enables AUX J9 operation
12: 00 00-99, Port 4 Track Number Adder or Latched Offset 36: 00 <AUX J9> Starting Folder Number, 00-99
13: 00 Song Play duration length (in sec) for Immediate Au toPlays 37: 00 00-99, Custom Wallbox Type "31" #1 (C1)
14: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #1 38: 00 00-99, Custom Wallbox Type "31" #2 (C2) 1
15: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #2 39: 00 00-99, Custom Wallbox Type "31" #3 (C3)
16: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #3 40: 00 00-99, Custom Wallbox Type "31" #4 (C4)
17: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #4 41: 00 00-99, Custom Wallbox Type "31" #5 (C5) 1
18: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #5 42: 00 00-99, Custom Wallbox Type "31" #6 (C6) 2
19: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #6 43: 00 00-99, Custom Wallbox Type "31" #7 (C7) 2
20: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #7 44: 00 00-99, Custom Wallbox Type "31" #8 (C8)
21: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #8 45: 00 <reserved> Factory usage only. 3
22: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #9 46: ## <reserved> Shows Major Program Version Number. 4
23: 99 00-98, 99= ignore, User Defined AutoPlay Folder to use #10 47: ## <reserved> Shows Minor Program Version Number. 4
SUMMARY OF SETUP ADDRESSES (Page 2)
ADR is the Setup Address location. RES is the Factory Default values.
1 Input values are internally modified by the set ting of Address 30. 2 Internally, the actual value is +156 higher. 3 To enable the 100 song folder test. [45:04] & [14:nn] nn= folder # 00-99 4 Changing these values forces a reset back to Fa ctory Defaults.
0000 Address Value
Colon symbol indicates SETUP
2g01 NOTE: In some areas of this manual ...
Text setup statements may be expressed within Squar e Brackets For example, [29:01] means Setup Adr 29: is set to Value "01".
This example sets the operating mode
for Seeburg DEC
Page 6 © 2021 Data Sync Engineering
WB-HUBe Player System Setup Configuration Details
Song Play Previews of Immediate Random AutoPlays
ADDRESS LOCATION
SETTING RANGE FACTORY
DEFAULT USER
SETTING
Preview Duration 13 00-99 00
Allows previewed plays during Random AutoPlay. Each song is played for 01-99 seconds, stopped, then to next song. The front panel GREEN LED turns on during preview play. Switch to full play of the current song by pressing the re mote CH+. "00" disables preview. Great for "Name-That-Song" e vents.
ADDRESS LOCATION
SETTING RANGE FACTORY
DEFAULT USER
SETTING
User AP Folder 1 14 00-98 99
User AP Folder 2 15 00-98 99
User AP Folder 5 18 00-98 99
User AP Folder 6 19 00-98 99
User AP Folder 7 20 00-98 99
User AP Folder 8 21 00-98 99
User AP Folder 9 22 00-98 99
User AP Folder 10 23 00-98 99
User Specified Folders for Random AutoPlays
User AP Folder 3 16 00-98 99
User AP Folder 4 17 00-98 99
Full AutoPlay mode picks random selections from ava ilable folders and track numbers.
These "User AutoPlay Folder" settings allow you to limit the song selections to a specific choice of up to ten i ndividual folders. Any setting with a folder range of 00 to 9 8 will cause AutoPlay to pick selections only from those folders .
Any setting of 99 will be ignored. All ten settings at 99 will cause full AutoPlay of all available folders.
ADDRESS LOCATION
SETTING RANGE FACTORY
DEFAULT USER
SETTING
PORT #1 09 00-99 00
PORT #2 10 00-99 00
PORT #3 11 00-99 00
PORT #4 12 00-99 00
4-Port Track Number Adder Offset (or Latched Offset ) These settings allow each wallbox input port to off set the song selection number to a specified position within the folder. "00" does not change the song selection numb er.
The setting is a latched offset if the input Type i s 30. This is typically used for some multiple signal wallb ox types to automatically offset the final song number.
ADDRESS LOCATION
SETTING RANGE FACTORY
DEFAULT USER
SETTING
PORT #1 05 00-99 01
PORT #2 06 00-99 01
PORT #3 07 00-99 01
PORT #4 08 00-99 01
4-Port Starting Folder Number These settings allow each wallbox input port to pla y selections starting at a specified folder number 00 to 99.
Keep in mind that each folder can have up to 100 son g selections, so if an input wallbox range is greater than 100 selections, the WB-HUBe will automatically move t o the next sequential folder number for selections.
The Seeburg "Digital Electronic Consolette" wallb ox operating mode uses the Port #1 Starting Folder Numbe r.
ADDRESS LOCATION
SETTING RANGE @60HZ
SETTING RANGE @50HZ
FACTORY DEFAULT
USER SETTING
PORT #1 01 00-31 32-63 06
PORT #2 02 00-31 32-63 06
PORT #3 03 00-31 32-63 06
PORT #4 04 00-31 32-63 06
4-Port Wallbox Input Type For each of the four ports, there are 32 input type settings numbered 00-31. These settings are used for 60hz lin e frequency operation. To operate at 50hz, add 32 to the input type. For example, the AMI W-120 input setting at 60hz is 06, but at 50hz, the setting would be 38 (0 6+32).
There are four special input type settings ... Type 28, enable Port 4 Play Trip for Random Track s Type 29, enable Port 4 Play Trip for Sequential Tracks Type 30, assign for Latched Offsets (not a wallbox type) Type 31, use the "Custom Wallbox Configuration" type
Page 7 © 2021 Data Sync Engineering
WB-HUBe Player System
ADDRESS LOCATION
SETTING RANGE FACTORY
DEFAULT USER
SETTING
CONFIG #1 (C1) 37 00-99 00
CONFIG #2 (C2) 38 00-99 00
CONFIG #3 (C3) 39 00-99 00
CONFIG #4 (C4) 40 00-99 00
CONFIG #5 (C5) 41 00-99 00
CONFIG #6 (C6) 42 00-99 00
CONFIG #7 (C7) 43 00-99 00
CONFIG #8 (C8) 44 00-99 00
4-Port Wallbox Type "31" Custom Configuration These eight settings, together with the [30:nn] modi fier, create a special type 31 "Custom Wallbox" configurat ion.
This in turn, sets up the "Electronic Stepper" func tion. The purpose of the Custom Configuration was to be ab le to develop new tables for unknown wallboxes & provi de the user with the setup values to manually enter. In rare cases, a table is created to compensate for a worn o ut motor or other mechanical differences.
Creating these values can only be done at the facto ry. They are not user friendly and require measurement instruments to sync up the Digital Filters and Decod ers.
ADDRESS LOCATION
SETTING RANGE
FACTORY DEFAULT
Auto-Play Mode 25 00-99 99
Sets the time duration from no play until autoplay
00 = Continuous autoplay 01 to 98 = Time duration at 1-minute intervals ( 20-minutes would be 20) 99 = Autoplay off
No Repeat Check 26 Program Generated X Number of previous selections for no-repeat AutoPla y checking. Not user settable.
Special Options 27 00-63 00
Special Options (add selected option dig its together for final setting)
00+1 [ ] Insert wallbox selections into no repeat autoplay m emory +2 [ ] Allow duplicate wallbox song selecti ons +4 [ ] Disable song selections from IR Remo te +8 [ ] - +16 [ ] - +32 [ ] Factory Test, 4-sec song play + other options
AP Multiplier 28 01-99 60 Autoplay duration interval multiplier (in 1-second ticks)
4-Port Op-Mode 29 00-99 00 00 = 4-Port wallbox input mode, non-zero = Seebu rg DEC mode
C2/C5 Mods 30 00-99 00 Custom Wallbox C2/C5 modifiers
31 00-99 00 <unasssigned>
32 00-99 00 <unasssigned>
33 00-99 00 <unasssigned>
AUX J9V 34 00-99 00 <AUX J9> Optional Setup Value (if required)
AUX J9E 35 00-99 00 <AUX J9> Non-zero enables AUX J9 operation
AUX J9F 36 00-99 00 <AUX J9> Starting Folder Number
Operating Condition Options
<reserved> Factory Usage Only
ADDRESS LOCATION
SETTING RANGE
FACTORY DEFAULT
Factory Test 45 00-99 00
Major Prog Ver 46 nn Changing this value forces a reset back to Factory Defaults after re-boot
Minor Prog Ver 47 nn Changing this value forces a reset back to Factory Defaults after re-boot
Non-Zero allows direct SETUP entry from Remote INPU T button
ADDRESS LOCATION
SETTING RANGE FACTORY
DEFAULT USER
SETTING
Remote to SETUP 24 00-99 00
If not zero, pressing the Remote INPUT causes a dir ect entry into the SETUP mode, displays [00:00]
If enabled, this may cause an annoyance if the INPU T button was accidentally pressed. Re-booting is the same as pow er-up and will erase all saved song selections.
Setup Configuration Details
Page 8 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Model Type Codes and Play Trip
Wallbox Model Type Description
13 08 40 100 Wurlitzer 5225
10 09 41 24 Wurlitzer 3020, 120VAC powered
10 09 41 48 Wurlitzer 4851, 4-wire terminals, (requires 2-Po rts)
10 10 42 104 Wurlitzer 5204 , 7-wire terminals, (requires 4-po rts)
11 11 43 120 RockOla 1544 & 1546
16 12 44 160 RockOla 506 Tri-View, (SIGNAL / COM)
12 13 45 104 Wurlitzer 5204A, 3-wire terminals
11 14 46 120 RockOla 1542 & 1548
16 15 47 160 RockOla 507 Tri-View, (SIGNAL / 24VAC)
9 16 48 100 RockOla Electronic JRW, "Johnny Rockets"
28 X Assign Port 4 Play Trip, Random Track Selections
29 X Assign Port 4 Play Trip, Sequential Track Selection s
30 X Assign for Latched Offset Captures (not a WB type)
31 63 Port to use "Custom Wallbox Configuration" type
Code @
60Hz
Wiring P
age
Code @
50Hz
Selections
Wallbox Model Type Description
14 00 32 200 Rock-Ola 1555
15 00 32 160 Rock-Ola 1558
15 00 32 160 Rock-Ola 500
12 01 33 160 Seeburg Consolette SC-1, SC-2, SC-3 & SC-4
12 01 33 160 Seeburg Consolette SCH1, SCH2, SCH3 & SCH4
13 02 34 200 Wurlitzer 5210
14 02 34 200 Wurlitzer 5250
13 02 34 200 Wurlitzer 5220
11 03 35 100 Seeburg Wall-O-Matic 3W1
11 03 35 100 Seeburg Wall-O-Matic 3W100
12 04 36 200 Seeburg Wall-O-Matic 3WA
12 04 36 160 Seeburg Wall-O-Matic 3W160
14 05 37 200 Rowe WRA & WRB
14 05 37 200 Rowe WRC
13 06 38 40 AMI W-40
13 06 38 80 AMI W-80
13 06 38 120 AMI W-120
15 06 38 200 AMI WQ-200
16 07 39 104 Wurlitzer 5207, 4-wire terminals
Code @
60Hz
Wiring P
age
Code @
50Hz
Selections
WALLBOX PORT TYPE CODES for SETUP Addresses 01:, 02 :, 03: & 04:
Set [29:01] to assign for Seeburg "Digital Electron ic Consolette" (160 select) to all four ports, wiri ng on Page 9
Play Trip Feature
The "Play Trip" feature allows a selectable number of tracks to be played when an AC or DC 5-30V signal is applied to Port 4. Play Trips are accumulative but require a 2.25sec g ap between signals. Continuous signals are ignored until after the 2.25 sec gap period. Upon a play trip, the specified number of tracks ar e added to the total number of tracks to be played, holding at the maxim um 255 tracks. Played tracks can be set as sequential from a singl e folder (with auto increment and restart) or random from all available folders or limited to only user specified folders. Suitable for selectors with only a coin switch or t imer. For arcade machines or stage effects, a 5-Volt signal at J5-1 (SIG), turns on during the track play duration which can be used with a So lid State Module to supply the AC power for the lights and animatronics . Here are the SETUP (Address) descriptions (04:nn) "Wallbox Type number" Enter 28 for Sequential Tracks from the selected folder Enter 29 for Random Tracks from all or user specified folders (08:nn) "Starting Folder Number" Enter the folder number for the Seq uential Tracks, nn= 00-99 (12:nn) "Track Number Adder Offset" Enter the number of tracks to play for each trip, nn= 01-99
GREEN
BLACK BLACK
WHITE
120VAC INPUT
120VAC OUTPUT
Basic wiring for AC Power Control Coin Switch Timer Switch Push Button
1 2
3
4
5 6
7
8
VCC J5-2
(1) SIG (2) VCC (3) GND (4) V+ (5)
SIG (1) VCC (2) GND (3)
V+ (4) (5)
J5
MU
TE
GN
D J
5-3
SIG
J
5-1
J5 on MULTI-PORT UNIVERSAL
Circuit Board
GND J5-3
Port #4
Example if you want to use
internal power for Play Trip
Solid State Module INPUT: 3-32VDC
AC Relay: 24-380VAC
JST XH 5-Pin
This circuit example was used in a "Bimbo the Clown " arcade machine
Page 9 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams
Seeburg "Digital Electronic Consolette", 160 select models DEC1, DEC2, DEC3 and DEC4
Black connected to Pins 2, 4, 6 & 8
Electrical Wiring Diagram
WH
T
GR
Y
VIO
B
LU
GR
N
YE
L
OR
N
RE
D
BR
N
BLK
(1) ORN
(3) RED
(7) BLU
Wallbox 24VAC Power Transformer
Speaker COM
Audio Control
DATA "D"
Speaker RCH
Speaker LCH
DATA "A"
DATA "B"
DATA "C"
(5) BRN
Seeburg Model DEC4
1 2
3
4
5 6
7
8
4x Diodes 1N4002
Setup Configuration
[29:01] Seeburg DEC mode [05:nn] nn= Song Folder #
This wallbox uses two consecutive song folders Additional wallboxes can
be daisy-changed together Number of ports used: 4
Rock-Ola JR1/JRW, "Johnny Rockets" Seeburg 3W1 Repl ica Wallbox
Electrical Wiring Diagram
Shown here being connected to Wallbox Port 1 (any of the four ports can be used)
Set all dipswitch settings to the
OFF (up) position
BLUE SIG
GRN PWR
RED GND
Wallbox 24VAC Power Transformer
Diode 1N4002
1 2
3
4
5 6
7
8
Setup Configuration
[01:16] Port 1 WB type [05:nn] nn= Song Folder # [09:00] No song track add [29:00] 4-port WB mode
Number of ports used: 1
Page 10 © 2021 Data Sync Engineering
WB-HUBe Player System
Wurlitzer Model 5204 Wallbox, 104 select (with 7-Sc rew Terminals)
7
6
5
4
3
2
1
SIG4
SIG3
SIG2
N/C
24VAC
COM
SIG1
Wallbox 24VAC Power Transformer
1 2
3
4
5 6
7
8
To Pins 2, 4, 6 & 8
SIG1
SIG2
SIG3
SIG4
SETUP CONFIGURATION
[01:10] WB Type (+32 @50H) [02:30] Port 2 latch [03:30] Port 3 latch [04:30] Port 4 latch [05:nn] nn= Start Folder # [09:00] No song track add [10:26] Port 2 offset =26 [11:52] Port 3 offset =52 [12:78] Port 4 offset =78 Number of ports used: 4
Electrical Wiring Diagram
Wurlitzer Model 4851 Wallbox, 48 select (with 2-Pag e Select Knob)
4
1
2
3
SIG2 (25-48)
SIG1 (1-24)
COM
24VAC
Wallbox 24VAC Power Transformer
1 2
3
4
5 6
7
8
SIG1
SIG2
Number of ports used: 2
Electrical Wiring Diagram
SETUP CONFIGURATION
[01:09] Port 1 WB Type (+32 @50H) [02:09] Port 2 WB Type (+32 @50H) [05:01] Port 1 Start Folder # 01 [06:01] Port 2 Start Folder # 01 [09:00] Port 1 Offset to 0 [10:24] Port 2 Offset to 24
To Pins 1 & 3
Wallbox Wiring Diagrams
This wallbox has its own “built-in” transformer and requires a 120VAC power cord. The wallbox adapter only requires the two wire connection to terminal #1 and terminal #3.
To Port #
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
Wurlitzer Model 3020 Wallbox (24 select)
24VAC SIGNAL Warning! 115VAC
115VAC
Page 11 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams
COM Wallbox
24VAC Power Transformer
24VAC
SIG To Port #
Seeburg Wall-o-matic 3W1 / 3W100 (100 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
Rock-Ola 1544/1546 Wallbox, 20-Buttons, 6-Pages, 12 0-Select
Setup Configuration
[01:11] Port 1 WB type [05:nn] nn= Song Folder # [09:00] No song track add [29:00] 4-port WB mode
Electrical Wiring Diagram
Shown here being connected to Wallbox Port 1 (any of the four ports can be used)
Number of ports used: 1
Wallbox 24VAC Power Transformer
24VAC
SIG
COM
To Port #
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
115VAC Input (Black Wires)
General Wiring Diagram for 3-Wire Wallbox Model Typ es
WALLBOX SELECTOR
COM
24VAC
SIG Wallbox Transformer 24VAC @2A (48VA)
To Port # Any Port #
can be used
No wire polarity
Secondary
Prim
ary
jameco.com
P
art # 112513
24VAC Output (White Wires)
In-line fuse holder with 1A fuse
CABLE WIRE COLORS GRN 24VAC ORN COM BLU SIG
Page 12 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams
Wallbox 24VAC Power Transformer
CO
M
24V
AC
SIG
To Port #
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
Seeburg Wall-o-matic 3WA / 3W160 (200/160 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
Seeburg Consolette SC1 to SC4 and SCH1 to SCH4 (1 60 select)
COM BLK
SIG BLU
Wallbox 24VAC Power Transformer
24VAC WHT
To Port #
To enable coin operation, the BRN / RED / ORG terminals must be shorted together and connected to the 24VAC terminal (WHT)
SPEAKER TERMINALS
GRY Speaker Common GRN Right Channel YEL Left Channel
COM
24VAC
SIGNAL 1
3
2
Wurlitzer 5204A (104 select)
Wallbox 24VAC Power Transformer
To Port #
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
SIGNAL
24VAC
COM
Page 13 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams 1
2
3 4
5
6
7 8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
Wurlitzer 5220 (200 select) and Wurlitzer 5225 (100 select)
SIG 1
COM
G
24 VAC 3
2
To Port # Wallbox 24VAC Power Transformer
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
AMI W-40 / W-80 / W-120 (40 / 80 / 120 select)
24VAC
Wallbox 24VAC Power Transformer
SIG
COM
To Port #
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
Wurlitzer 5210 (200 select)
Wallbox 24VAC Power Transformer
COM
SIG
To Port #
24VAC
Page 14 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams
Wallbox 24VAC Power Transformer
To Port #
Rowe WRA / WRB / WRC (200 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
A wire jumper must be inserted from the 24VAC main power terminal (#2) to the 24VAC* keypad motor terminal (#4).
24VAC
SIGNAL
COM
CO
M
24V
AC
24V
AC
*
SIG
NA
L
Wallbox 24VAC Power Transformer
To Port #
Wurlitzer 5250 (200 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
SIGNAL
24VAC
COM C
OM
24V
AC
SIG
NA
L
Wallbox 24VAC Power Transformer
To Port #
Rock-Ola 1555 (200 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
SIGNAL
24VAC
COM
CO
M
24VA
C
SIG
NA
L
Page 15 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams
Wallbox 24VAC Power Transformer
To Port #
Rock-Ola 500 (160 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
24VAC
SIGNAL
COM CO
M
24VA
C
SIG
NA
L
Wallbox 24VAC Power Transformer
To Port #
AMI WQ-200 (200 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
SIGNAL
24VAC
COM
A wire jumper must be inserted from the 25VAC main power terminal to the 25VAC* lock-out.
CO
M
24V
AC
SIG
NA
L
24V
AC
*
Wallbox 24VAC Power Transformer
To Port #
Rock-Ola 1558 (160 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
SIGNAL
24VAC
COM CO
M
24VA
C
SIG
NA
L
Page 16 © 2021 Data Sync Engineering
WB-HUBe Player System Wallbox Wiring Diagrams
Wallbox 24VAC Power Transformer
To Port #
Wurlitzer 5207 (104 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
24VAC
SIGNAL
COM SIG
NA
L
CO
M
24VA
C
Wallbox 24VAC Power Transformer
To Port #
Rock-Ola Tri-Vue 506 and 507 (160 select)
1 2
3
4
5 6
7
8
Port 1
Port 2
Port 3
Port 4
Any Port # can be used
No wire polarity
SIGNAL
COM
RIG
HT
SP
EA
KE
R
AU
DIO
GR
OU
ND
LEFT
SP
EA
KE
R
AUDIO CONTROL
LOC
K-O
UT
WALLBOX TERMINAL
CONNECTIONS
CHASSIS GROUND
Rock-Ola Tri-Vue 506 / 507
COM
SIG
NA
L
24VA
C
Port Signals for the Tri-Vue Model 506: SIGNAL an d COM (Top P.C. board, green jumper wire, must be at t he "A" position)
Port Signals for the Tri-Vue Model 507: SIGNAL an d 24VAC
24VAC
WB-HUBe Kit Contents
Remote Set Up
Press & hold POWER and MUTE buttons
simultaneously until LED flashes on/off
then remains on.
Release buttons
Using the numeric keys
Enter 5320
LED should turn off
Blinking LED is error, perform set-up again
16.0
GB
16GB SD Memory Card Up to 3,200 song selections
using MP3 bitrate @192Kbps
USB 2.0 SD Reader
AC to 9VDC Power Cable
WB-HUBe Player System
Screw Terminal Plug for wallbox wiring
5ft Audio Cable
RC
H
LCH