Spare part stock Calibration room
Headquarters Goteborg, Sweden,
founded 1979
Sensor development
Manufacture & assembly
Marketing and Sales
Service
Global organisationHeadquarters in Gothenburg.
-Management
-Development
-Production
-Service
NA office in Charlotte, NC
-Sales
-Service
Offices in the UK, Germany and Finland.
PreciCura SR/MR/LR
MR = Measurement RangeSO = Stand-Off distanceCE = SO=Xmin=Close End
Sensor output=MRFE = SO+MR=Xmax=Far End
Sensor output=0
CEXmin
FEXmax
Definitions
Technical specifications:
Measurement Range (MR): 100 … 8000 mmCCD array: 2000 pixels.Resolution: MR / 32000 (16 x sub-pixel)Power supply: +24 VDC (18-32 VDC)Diode laser: 1 to 20 mW Laser class: 2, 2M, 3R or 3BWave length: 635-670 nmMeasuring frequency: 2000 HzWorking temperature: 0 – 40 C
PreciCura SR PreciCura MR PreciCura LR
162 x 108 x 42 mm 303 x 149 x 57 mm 524 x 149 x 57 mm
1,0 kg 3,0 kg 5,0 kg
The PreciCura family
• Serial RS232 HOST (MR/LR only)• up to 115200 bit/s
• ASCII - FORMATS
• CAN-bus• Field bus system• up to 1 Mbit/s (Bus length 40 m)• up to 250 Kbit/s (Bus length 200 m)• Real time bus system• to combine with PLC, Encoder…
• Analog• 16 bit• 0…20 mA or 4…20 mA
C1: serial RS232 service interfaceC2: Main connector, Power supply CAN-bus and Analog interfaceC3: Serial RS232 HOST interface and sensor synchronization
Interfaces
Delivery includes:
- Manual in English
- 2 meter cable for the C2 connector
- Serial RS232 interface for setup and service
- CAN-bus and Analog (0 or 4 to 20 mA) interface
PreciCura SR
PreciCura SR
Options:
3-point bracket: Mounting bracket for easy fineadjustment of the sensor.
PreciCuraSet: Windows® based setup software.Incl. 5 meter cable to PC.
Air knife: For compressed air.
Blower unit: Front mounted. For fan driven air.
Calibration fixture: Rotating calibration target on an arm.Ideal for thickness calibration.
Cooling box (Air): Protective enclosure with fan drivenair cooling connection.
Delivery includes:
- Manual in English
- 2 meter cable for the C2 connector
- Serial RS232 interface for setup and service
- CAN-bus, Analog (0 or 4 to 20 mA) and serial RS232 HOST interface
PreciCura MR
PreciCura MR
Options:
Measurement Range: 100 < MR < 2000 mm, resolution 0,01or 0,1 mm depending on MR
Mounting bracket: Mounting bracket for easy fineadjustment of the sensor.
PreciCuraSet: Windows® based setup software.Incl. 5 meter cable to PC.
Air knife: For compressed air.
Blower unit: Front mounted. For fan driven air.
Cooling box (Air): Protective enclosure with fan drivenair cooling connection.
Delivery includes:
- Manual in English
- 2 meter cable for the C2 connector
- Serial RS232 interface for setup and service
- CAN-bus, Analog (0 or 4 to 20 mA) and serial RS232 HOST interface
PreciCura LR
PreciCura LR
Options:
Measurement Range: 600 < MR < 8000 mm, resolution 0,1or 1 mm depending on MR
Mounting bracket: Mounting bracket for easy fineadjustment of the sensor.
PreciCuraSet: Windows® based setup software.Incl. 5 meter cable to PC.
Air knife: For compressed air.
Blower unit: Front mounted. For fan driven air.
Cooling box (Air): Protective enclosure with fan drivenair cooling connection.
Protection and cooling box Brackets
Calibration unit Big display
PreciCuraSet
Accessories
- Rugged, industrial design
- No moving parts
- Not sensitive for colour variations
- Center-of-Gravity evaluation of measured distance and 16-times subpixel => increased resolution and accuracy
- CCD evaluation of distance => less sensitive for dirt on the front glasses, secondary reflections and background radiation
- No extra control unit
Benefits
Target: rotating white paper
Target: white paper, not moving
Speckle effect
Filter algorithms:
•Average Filter length: 2-1000 (Filter length = 1 => No filter).Data output rate is reduced proportional to theFilter length.
• Moving Average Filter length: 2-1000 (Filter length = 1 => No filter).Data output rate is NOT reduced by the Filter
length.
• Median Sorting the content of the data buffer. Normally uses the middle value of the buffer as
output.Can also be used as a min/max filter. Eliminates spikes in the data.
Filters
Filters
Control of data input to the filter:
- Continuous Fixed filter length (settable between 1-1000).
- Trig The filter length is controlled by the leading(positive) flanks of the trigger input.
- Gate The filter length is controlled by the leadingand trailing flanks of one trig pulse.
- Self trig The Filter length is controlled by the internalerror messages in the sensor (Valid data/”NO OBJECT”) i.e. the measurement target controls the filter length. (e.g. in thickness measurement applications of a board).
UpperPreciCura
LowerPreciCura
CAN-busConn. box
Upper PreciCura:
Measuring mode: DistanceCAN bus ID: 101Filter type: AveragingFilter Length: 1Synchronization mode: Slave (option)
Lower PreciCura:
Measuring mode: ThicknessCAN bus ID: 100Filter type: According to applicationFilter Length: According to applicationSynchronization mode: Master (option)Outputs available: CAN-bus, Analog, Serial RS232
Thickness measurement