7
UP UP UP LIFT LIFT 340.2 m² / 3662 ft² Office 12.2 m² / 132 ft² Female 9.7 m² / 104 ft² Male Stair 2 Stair 1 A 3100 B 3101 C 3102 D 3102 W501 W502 W503 W504 ED05.01 ED05.04 ED05.02 ED05.05 D506.02 D506.03 D504.02 D507.03 D501.02 D501.01 ED05.03 D504.01 D502.01 D506.01 D507.01 D503.01 D501.03 3 5901 4 5901 5 5902 2 5900 3 5105 4 5105 6 5903 7 5903 1 5900 D509.01 D509.02 D509.04 D506.04 D506.05 D507.02 IPS IW12 IW14 IW12 IPS IPS IPS IW12 IW12 IW12 IW14 IPS IW12 IW12 IW14 IW14 IW12 IW12 IPS IW13 3.4 m² / 37 ft² Acc. WC / 508 IPS D509.03 Door opening to be widened to fit a 1010mm doorset Teapoint location indicative, for tenant fitout 1.1 m² / 12 ft² Cleaner's Cupboard / 505 +17.630 m +17.742 m +17.742 m +17.630 m B C 2 3 4 5 6 A D 1 6495 4520 7470 3000 6725 5450 7480 4855 1480 757 Partition Key Existing Partition Proposed Partition IW Internal Wall Types Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification For AWW Site Location Plan see drawing 0100 For AWW Demolition Drawings see 1200 series For AWW Existing Drawings see 1500 series For AWW Proposed GA Plans see 2000 series For AWW Acoustic Strategy Drawings see 2200 series For AWW Fire Strategy Drawings see 2300 series For AWW Access & Security Drawings see 2400 series For AWW Wall Types see drawing 2500 For AWW Floor Build-Ups Drawings see 2650 series For AWW Finishes Drawings see 2700 series For AWW Reflected Ceiling Plans see 2800 series For AWW Proposed Elevations see 3000 series For AWW Proposed Sections see 3100 series For AWW Core & WC Drawings see 5000 series For AWW Lifts & Stairs Drawings see 5100 series For AWW Key Internal Space Drawings see 5300 series For AWW Strip Sections see 5900 series For AWW Detail Drawings see 6000 series For AWW Area Schedules see drawing 7000 For AWW Door Schedules & Legends see 7200 series For AWW Window Schedules & Legends see 7300 series For AWW Interior Design Drawings see 9000 series Please read in conjunction with AWW NBS Specification & finishes Schedules Structures and MEP information indicative, refer to respective Tender information for details. For structural and civil engineering proposals refer to Fairhurst drawings and specification For mechanical, electrical & public health proposals refer to WPP drawings and specification For repairs to existing building refer to TMD repair works schedule and specification Drawing References Setting Out Point Setting Out Point inspired environments N or t h Notes Init Notes Rev Date Status Drawing No. Revision Drawing Title Project Title Sheet Drawn Checked Chkd A1 This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes. Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice. London - 106 Weston Street London SE1 3QB Bristol - Rivergate House, Bristol, BS1 6LS Plymouth - East Quay House, Plymouth, PL4 0HX RIBA Chartered Practice Project No. Drawing Reference Drawing Originator Client 020 7160 6000 0117 923 2535 01752 261 282 www.aww-uk.com Date Scale 1:50 1 : 50 C 3873 100 St John Street Proposed Fifth Floor GA Plan Clerkenwell London, EC1M 4EH CONSTRUCTION DH 25/05/18 2006 SW STJ-AWW-A-DWG VISUAL SCALE 1:50 5m 1m 4m 3m 2m 0m A 12/07/18 SW Amendments to Tender information IS B 08/10/18 SW Construction Issue IS C 13/06/19 SW Section 2 Record Issue IS

1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

UP

LIFT LIFT

340.2 m² / 3662 ft²Office

12.2 m² / 132 ft²

Female9.7 m² / 104 ft²

Male

Sta

ir 2

Stair 1

A

3100

B

3101

C

3102

D

3102

W501

W502

W503

W504

ED05.01ED05.04

ED05.02ED05.05

D506.02

D506.03

D504.02

D507.03

D501.02D501.01

ED05.03

D504.01

D502.01

D506.01

D507.01

D503.01

D501.03

3

5901

4

5901

5

5902

2

5900

3

5105

4

5105

6

5903

7

5903

1

5900

D509.01

D509.02

D509.04D506.04

D506.05

D507.02

IPS

IW12

IW14

IW12

IPS

IPS IPS

IW12 IW12

IW12

IW14 IPS IW12

IW12

IW14 IW14

IW12

IW12

IPS

IW13

3.4

/ 37 ft²

Acc. W

C / 5

08 IPS

D509.03

Door opening to be widened to fit a 1010mm doorset

Teapoint location indicative, for tenant fitout

1.1 m² / 12 ft²Cleaner's Cupboard / 505

+17.630 m

+17.742 m +17.742 m

+17.630 m

B

C

2 3 4 5 6

A

D

16495 4520 7470 3000 6725

5450

7480

4855

1480

757

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

C

3873

100 St John Street

Proposed Fifth Floor GA Plan

Clerkenwell

London, EC1M 4EH

CONSTRUCTION

DH 25/05/18

2006

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 08/10/18 SW Construction Issue IS

C 13/06/19 SW Section 2 Record Issue IS

Page 2: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

459.7 m² / 4948 ft²Office / 401

15.5

/ 16

6 ft²

Sta

ir 2

/ 4

03

16.8 m² / 181 ft²Stair 1 / 402

A

3100

B

3101

C

3102

D

3102

W409 W410W408

W401

W402

W403

W406

W407

W405

W418

W417

W412

W411

W404 W415

W414

W416

W413

D402.01

D406.02

D407.03

D401.02D401.01

D404.01

D406.01

D407.01 D403.01

D404.03

D404.02

D409.01

D409.04

D406.03

D406.04

D407.02

IW03

3

5901

4

5901

5

5902

2

5900

3

5105

4

5105

6

5903

7

5903

1

5900

IPS IW14 IPS

IPS IPSIW14 IPS IW12 IW14 IW14

IW12

IW12

IPS

IW13

3.4

/ 37 ft²

Acc. W

C / 4

08 IPS

D409.03

Door opening to be widened to fit a 1010mm doorset

Teapoint location indicative, for tenant fitout

LIFT LIFT

+14.100 m

B

C

2 3 4 5 6

A

D

16495 4520 7470 3000 6725

5450

7480

4855

500

500

IW05

IW03

1.1 m² / 12 ft²Cleaner's Cupboard / 405

12.2 m² / 132 ft²

Female8.8 m² / 95 ft²

Male

D409.02

IW12

IW12 IW12 IW12

IW12

IW12

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

D

3873

100 St John Street

Proposed Fourth Floor GA Plan

Clerkenwell

London, EC1M 4EH

CONSTRUCTION

DH 25/05/18

2005

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 08/10/18 SW Construction Issue IS

C 30/11/18 DH Revised Comms Cupboard andStorage Layout at Lower Ground,

Removed Excess Risers Ground to

Fourth, Revised Basement Door to

Stair 2, Updated Lightwell Glazing,

Updated Ground Floor Stair Walls

IS

D 13/06/19 SW Section 2 Record Issue IS

Page 3: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

463.7 m² / 4991 ft²Office / 301

15.5

/ 16

6 ft²

Sta

ir 2

/ 3

03

16.8 m² / 181 ft²Stair 1 / 302

A

3100

B

3101

C

3102

D

3102

W312 W313W311

W301

W302

W309

W310

W320

W319

W315

W314

W303

W308

W307

W304

W318

W316

W214

W213

W305

W306

D302.01

D304.03

D306.02

D304.02

D307.03

D301.01D301.02

D304.01 D307.01 D303.01

D309.01

D309.03

D309.04D306.03

D306.04

D307.02

D306.01

IW03

3

5901

4

5901

5

5902

2

5900

3

5105

4

5105

6

5903

7

5903

1

5900

IPS IW14 IPS

IPS IPSIW14 IPS IW12 IW14 IW14

IW12

IW12

IPS

IW13

3.4

/ 37 ft²

Acc. W

C / 3

08 IPS

Door opening to be widened to fit a 1010mm doorset

Teapoint location indicative, for tenant fitout

LIFT LIFT

+10.580 m

B

C

2 3 4 5 6

A

D

16495 4520 7470 3000 6725

5450

7480

4855

500

500

IW05

IW03

1.1 m² / 12 ft²Cleaner's Cupboard / 305

12.2 m² / 132 ft²

Female8.8 m² / 95 ft²

Male

D309.02

IW12

IW12 IW12 IW12

IW12

IW12

-

---

-

---

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

D

3873

100 St John Street

Proposed Third Floor GA Plan

Clerkenwell

London, EC1M 4EH

CONSTRUCTION

DH 25/05/18

2004

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 08/10/18 SW Construction Issue IS

C 30/11/18 DH Revised Comms Cupboard andStorage Layout at Lower Ground,

Removed Excess Risers Ground to

Fourth, Revised Basement Door to

Stair 2, Updated Lightwell Glazing,

Updated Ground Floor Stair Walls

IS

D 13/06/19 SW Section 2 Record Issue IS

Page 4: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

463.6 m² / 4990 ft²Office / 201

3.4

/ 37 ft²

Acc. W

C / 2

08

15.5

/ 16

6 ft²

Sta

ir 2

/ 2

03

16.8 m² / 181 ft²Stair 1 / 202

A

3100

B

3101

C

3102

D

3102

W208 W209W207

W217

W2016

W211

W210

W203

W204

W201

W202

W205

W206

W104

W215

W212

W214

W213

D202.01

D207.03

D201.02D201.01

D204.01D203.01D207.01

IW03

3

5901

4

5901

5

5902

2

5900

4

5105

6

5903

7

5903

1

5900

D204.02

D204.03

D206.02

D206.03

D206.01

D206.04 D209.04

D209.01

D207.02

IPS IW14 IPS

IPS IPSIW14 IPS IW12 IW14 IW14

IW12

IW12

IPS

IW13

IPS

D209.03

Door opening to be widened to fit a 1010mm doorset

Teapoint location indicative, for tenant fitout

3

9004

LIFT LIFT

+7.050 m2

9005

B

C

2 3 4 5 6

A

D

16495 4520 7470 3000 6725

5450

7480

4855

500

500

IW05

IW03

1.1 m² / 12 ft²Cleaner's Cupboard / 205

12.2 m² / 132 ft²

Female8.8 m² / 95 ft²

Male

D209.02

IW12

IW12

IW12 IW12

IW12

IW12

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

D

3873

100 St John Street

Proposed Second Floor GA Plan

Clerkenwell

London, EC1M 4EH

CONSTRUCTION

DH 25/05/18

2003

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 08/10/18 SW Construction Issue IS

C 30/11/18 DH Revised Comms Cupboard andStorage Layout at Lower Ground,

Removed Excess Risers Ground to

Fourth, Revised Basement Door to

Stair 2, Updated Lightwell Glazing,

Updated Ground Floor Stair Walls

IS

D 13/06/19 SW Section 2 Record Issue IS

Page 5: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

UP

462.9 m² / 4982 ft²Office / 101

15.5

/ 16

6 ft²

Sta

ir 2

/ 1

03

16.2 m² / 175 ft²Stair 1 / 102

A

3100

B

3101

C

3102

D

3102

W114

W113

W109

W108

W103

W105

W101

W102

W106

W107

W104

W112

W111

W110

D102.01

D104.03

D106.02

D104.02

D107.03

D101.02D101.01

D106.01

D103.01D104.01 D107.01

IW03

IW05

3

5901

4

5901

5

5902

2

5900

3

5105

4

5105

6

5903

7

5903

1

5900

D109.01

D109.03

D109.04

D106.03

D106.04

D107.02

IPS IW14 IPS

IPS IPSIW14 IPS IW12 IW14 IW14

IW12

IW12

1

5102

2

5102

IPS

IW13

3.4

/ 37 ft²

Acc. W

C / 1

08 IPS

1

5101

2

5101

Door opening to be widened to fit a 1010mm doorset

Teapoint location indicative, for tenant fitout

LIFT LIFT

+3.530 m

1

6036

2

9005

B

C

2 3 4 5 6

A

D

16495 4520 7470 3000 6725

5450

7480

4855

500

500

IW03

1.1 m² / 12 ft²Cleaner's Cupboard / 105

12.2 m² / 132 ft²

Female8.8 m² / 95 ft²

Male

D109.02

IW12

IW12 IW12 IW12

IW12

IW12

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

D

3873

100 St John Street

Proposed First Floor GA Plan

Clerkenwell

London, EC1M 4EH

CONSTRUCTION

DH 25/05/18

2002

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 08/10/18 SW Construction Issue IS

C 30/11/18 DH Revised Comms Cupboard andStorage Layout at Lower Ground,

Removed Excess Risers Ground to

Fourth, Revised Basement Door to

Stair 2, Updated Lightwell Glazing,

Updated Ground Floor Stair Walls

IS

D 13/06/19 SW Section 2 Record Issue IS

Page 6: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

UP

UP

UPUP

UP

LIFT LIFT

ST

JO

HN

ST

RE

ET

VOID

VO

ID

5.1 m² / 55 ft²Acc. WC / G03

60.6 m² / 653 ft²Reception / G02

344.5 m² / 3708 ft²

Office / G01

Facade details TBC with fire engineer in response to

proximity of adjacent building

Ventilation louvre to sub-station below

Re

mova

l o

f cro

sso

ver

an

d r

etu

rn t

o f

ootw

ay

by

Lo

ca

l A

uth

ority

H

igh

wa

ys D

ep

art

me

nt

A

3100

B

3101

C

3102

D

3102

IW01

IW01

IW15

IW03

IW03

IW15

IW03

IW18

IW03

IW03

IW03

3

5901

4

5901

5

5902

1

5104

2

5105

1

5105

4

5105

6

5903

7

5903

1

5900

DG01.01

DG02.01

DG02.02

DG01.03DG01.02

DG05.01

DG03.02

IW16

1

5102

2

5102

DG03.01

1

5101

2

5101

IW04

Door opening to be widened to fit a 1010mm doorset

Teapoint location indicative, for tenant fitout

0

-870

0

0

0

0.9 m² / 10 ft²Cleaner's Cupboard / G04

GF

5105

2

9005

B

C

2 3 4 5 6

A

D

16495 4520 7470 3000 6725

5450

7480

4855

670

500

Sub-station access

IW03

IW03

4

5106

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

G

3873

100 St John Street

Proposed Ground Floor GA Plan

Clerkenwell

London, EC1M 4EH

RECORD

DH 25/05/18

2001

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 23/07/18 SW Amendments to Tender information.Glazing line at ground floor on front

elevation amended and columns

reclad, metalwork and stone

decoration to front elevation retained,

flagpole and stone base retained with

semi-circular stone element

reworked, circulation and lift lobby at

Lower Ground floor amended, floor

build-up 9 updated to hollowcore

IS

C 08/10/18 SW Construction Issue IS

D 02/11/18 SW Sub-station ventilation arrangementamended following comments from

UKPN

IS

E 30/11/18 DH Revised Comms Cupboard andStorage Layout at Lower Ground,

Removed Excess Risers Ground to

Fourth, Revised Basement Door to

Stair 2, Updated Lightwell Glazing,

Updated Ground Floor Stair Walls

IS

F 28/03/19 SW Section 1 Record Issue IS

G 13/06/19 SW Section 2 Record Issue IS

Page 7: 1 2 3 4 5 6...Office / 201 Acc. WC / 208 3.4 m² / 37 ft² Stair 2 / 203 15.5 m² / 166 ft² 16.8 m² / 181 ft² Stair 1 / 202 A 3100 B 3101 C 3102 D 3102 W207 W208 W209 W217 W2016

UP

UP

UP

1100 L 1100 L

11

00

L11

00

L

LIFT LIFT

18.1 m² / 195 ft²Water Tank / B21

26.5 m² / 286 ft²

Sub-Station / B23

10.7 m² / 115 ft²

Electrical Equipment Room /B08

8.6

/ 92 ft²

Sh

are

d L

ocke

r A

rea

/ B

09

46.3 m² / 499 ft²Cycle Store / B07

13.3

/ 14

3 ft²

Re

fuse

Sto

re / B

06

19.6 m² / 211 ft²

Circulation / B04

11.5 m² / 124 ft²Lift Lobby / B03

ROOFLIGHT ABOVE

VO

ID A

BO

VE

325.0 m² / 3498 ft²Office / B01

44 CyclesD

ryin

g C

abin

et

6.9 m² / 74 ft²Stair 2 / B02

A

3100

B

3101

C

3102

D

3102

VOID ABOVE

IW11

IW03

IW08

IW08

IW03

IW03

IW03

IW08

IW03

IW03

IW09

IW09

IW06

IW06

IW09

IW06

IW06

IW08

IW08IW06

IW06 IW06

IW03

IW03

IW02

IW02

IW06

IW08

IW10

IW18

IW08

IW03

IW10

3

5901

4

5901

5

5902

2

5900

1

5104

2

5105

1

5105

3

5105

4

5105

6

5903

7

5903

1

5900

DB05.02

DB05.01

DB03.01

DB04.01

DB07.01

DB08.01

DB04.02

DB05.03

DB12.01

DB04.03

DB10.02

DB15.01

DB04.04

DB09.02

DB18.01

DB16.01

DB03.03

DB01.01

DB09.01

DB10.01

DB10.03

DB02.02

DB02.01

Earth Rod

IW08IW06

DB03.02

5.8 m² / 63 ft²Female Showers / B10

5.5

/ 59 ft²

Ma

le S

ho

we

rs / B

15

6.1 m² / 66 ft²Accessible Shower / B14

1.4 m² / 15 ft²Gas Cupb'd / B22

1

5101

2

5101

IW08

IW10

1.0 m² / 11 ft²Welfare Facility / B20

New doorset in existing opening due to position of soffit of stairs above

0.8 m² / 9 ft²Comms / B19

-3.520 m

-3.500 m

-3.520 m LG

5105

0.6 m² / 6 ft²

BM Storage / B24

IW09

2

9005

B

C

2 3 4 5 6

A

D

1

measured from existing corner junction

2530

210

6495 4520 7470 3000 6725

5450

7480

4855

DB03.04

IW06

0.6 m² / 6 ft²Cleaner's Cupboard / B25

IW18

IW18

DB03.05

IW09

IW18

DB07.02

IW18

-3.520 m

Partition Key

Existing Partition

Proposed Partition

IW

Internal Wall Types

Indicates Internal Wall Type. For details see drawing 2500 and NBS Specification

For AWW Site Location Plan see drawing 0100For AWW Demolition Drawings see 1200 seriesFor AWW Existing Drawings see 1500 seriesFor AWW Proposed GA Plans see 2000 seriesFor AWW Acoustic Strategy Drawings see 2200 seriesFor AWW Fire Strategy Drawings see 2300 seriesFor AWW Access & Security Drawings see 2400 seriesFor AWW Wall Types see drawing 2500For AWW Floor Build-Ups Drawings see 2650 seriesFor AWW Finishes Drawings see 2700 seriesFor AWW Reflected Ceiling Plans see 2800 seriesFor AWW Proposed Elevations see 3000 seriesFor AWW Proposed Sections see 3100 seriesFor AWW Core & WC Drawings see 5000 seriesFor AWW Lifts & Stairs Drawings see 5100 seriesFor AWW Key Internal Space Drawings see 5300 seriesFor AWW Strip Sections see 5900 seriesFor AWW Detail Drawings see 6000 seriesFor AWW Area Schedules see drawing 7000For AWW Door Schedules & Legends see 7200 seriesFor AWW Window Schedules & Legends see 7300 seriesFor AWW Interior Design Drawings see 9000 series

Please read in conjunction with AWW NBS Specification & finishes Schedules

Structures and MEP information indicative, refer to respective Tender information for details.

For structural and civil engineering proposals refer to Fairhurst drawings and specification

For mechanical, electrical & public health proposals refer to WPP drawings and specification

For repairs to existing building refer to TMD repair works schedule and specification

Drawing References

Setting Out Point

Setting Out Point

inspiredenvironments

North

Notes

Init NotesRev Date

Status

Drawing No. Revision

Drawing Title

Project Title

Sheet Drawn Checked

Chkd

A1

This drawing may be scaled for the purposes of Planning Applications, Land Registry and for Legal plans where the scale bar is used, and where it verifies that the drawing is an original or an accurate copy. It may not be scaled for construction purposes.Always refer to figured dimensions. ALL DIMENSIONS RELATING BACK TO

EXISTING BUILDING ARE TO BE CHECKED ON SITE. Discrepancies and/or ambiguities between this drawing and information given elsewhere must be reported immediately to this office for clarification before proceeding. All drawings are to be read in conjunction with the specification and all works to be carried out in accordance with latest British Standards / Codes of Practice.

London - 106 Weston Street London SE1 3QB

Bristol - Rivergate House, Bristol, BS1 6LS

Plymouth - East Quay House, Plymouth, PL4 0HX

RIBA Chartered Practice

Project No.

Drawing Reference

Drawing Originator

Client

020 7160 6000

0117 923 2535

01752 261 282

www.aww-uk.com

DateScale

1:50 1 : 50

E

3873

100 St John Street

Proposed Lower Ground Floor GA

Plan

Clerkenwell

London, EC1M 4EH

RECORD

DH 25/05/18

2000

SW

STJ-AWW-A-DWGVISUAL SCALE 1:50

5m1m 4m3m2m0m

A 12/07/18 SW Amendments to Tender information IS

B 08/10/18 SW Construction Issue IS

C 30/11/18 DH Revised Comms Cupboard andStorage Layout at Lower Ground,

Removed Excess Risers Ground to

Fourth, Revised Basement Door to

Stair 2, Updated Lightwell Glazing,

Updated Ground Floor Stair Walls

IS

D 28/03/19 SW Section 1 Record Issue IS