    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Chapter 5 Troubleshooting for Clock

    5.1 Overview

    5.1.1 Description and Fault Causes in BSC Clock System

    Table 1.1 Description and fault causes in BSC clock system

    Fault causes Description

    Reference

    source fault

    The alarms DDS control data abnormal and Clock crystal oscillator override are

    reported on BSC alarm console. GCKS MOD indicator flashes slowly and most of

    the BTSs clock are out of lock.

    The alarms Clock source changed and Clock reference source abnormal/normal

    (alternatively) are displayed at the BSC alarm console. The MOD indicator or the

    F0/REFA indicator on the GCKS is constantly ON.

    After pulling out the two cables that introduces the two clock sources in the clock

    frame, the output 2MHz clock in the clock frame turns normal and most of the BTSs

    become locked.

    Board fault in

    clock frame

    On the maintenance console, GCKS is displayed red, or GCKS indicator is

    displayed abnormal, but turns normal after GCKS replacement.

    Clock alarms are displayed at the alarm console, but are removed after GCKS

    replacement.

    After pulling out the two cables that introduce the two clock sources in the clock

    frame, the CKB output clocks (including 2MHz, 4MHz, 8kHz and 32MHz) are tested

    abnormal and cannot recover even after GCKS replacement.

    Connection cable

    fault in clock

    frame

    On the maintenance console, GCKS is displayed red, the CLK indicator on GCKS

    flashes slowly. The fault cannot be removed even after GCKS replacement.

    On the maintenance console, GCTN/GSNT clock fault is reported, but the CKBoutput clock (including 2MHz, 4MHz, 8kHz and 32MHz) is tested normal by the

    frequency meter.

    Clock reference source fault alarm is reported on the BSC alarm console, and the

    F0/REFA indicator on the GCKS is ON.

    Data

    configuration

    fault

    On the maintenance console, GCKS is displayed red, the CLK indicator on the

    GCKS flashes slowly. The fault cannot be removed after GCKS replacement.

    1

  • 7/30/2019 05-troubleshooting for clocks.doc

    2/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    5.1.2 Description and Fault Causes in BTS Clock System

    I. Description and fault causes in BTS3X clock system

    Table 1.1 Description and fault causes in BTS3X clock system

    Fault causes Description

    Reference source

    problem

    13MHz clock out of lock alarm is reported.

    The BTS3X BSIC cannot be decode.

    The cell handover success rate is very low. The output 2MHz deviation of the

    MMU tested at the local end is large.

    Connection cable fault Clock-related alarms and test phase-lock ring alarm occur to all TRXs in the

    slots, accompanied with TRX repeated loading, TRX communication alarm

    and alarm removal report etc. But, no alarms occur to TMU, TDU indicators

    switches work normally and DIP switches set correct.

    Onsite operation error

    or BTS3X clock aging

    13MHz clock out-of-lock alarm occurs.

    Call drop occurs frequently.

    Handover success rate drops substantially.

    The output 2MHz clock of the TMU tested at the local end is normal.

    Board fault (TMU, TDU

    and TRX)

    TMU mailbox fault alarm occurs.

    TMU clock fault occurs. Clock-related alarm and repeated reset occur to all

    TRXs.

    Connection cables and TMU work normally, and DIP switches are correctly

    set. But, clock-related alarm and repeated reset occur to all TRXs.

    Clock-related alarm occurs to some TRXs.

    2

  • 7/30/2019 05-troubleshooting for clocks.doc

    3/31

  • 7/30/2019 05-troubleshooting for clocks.doc

    4/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    5.2 Fundamental Knowledge

    5.2.1 Introduction to BSC

    I. Introduction to BSC clock signal flow

    TCSM

    MSC

    E3M

    GCKS

    GCTN

    GFBI

    GOPT

    GNET

    GNOD/GLAP/GMC2

    E3M GSNT

    GMCC

    CKV BIE

    8kHz

    8kHz

    2MHz32MHz

    8kHz

    32MHz

    Figure I.1 Multi-module BSC clock signal flow

    As shown in Figure I.1, the path for multi-module BSC clock signals is as follows. Theclock is abstracted from MSC and is transmitted via TCSM and E3M to GCKS as8kHz reference source. GCKS traces the external reference signals and filters thejittering and drifting of the external reference signals to provide the high-stability clocksignals (32MHz, 8kHz and 4MHz) which the BSC required. The clocks output fromGCKS are first provided to the GCTN (32MHz, 4MHz and 8kHz) and the GSNT(32MHz and 8kHz) in AM. Then, they are driven by the GCTN to output the clocksignals (32MHz, 8kHz and 4MHz) to GFBI. Clock signals are transmitted to BMthrough the optical paths, and GOPT extracts the clock signals (2MHz and 8kHz) andtransmits them to the GNET in BM.

    The clock signals of the boards (GNOD, GLAP/LPN7 and GMC2) in the main controlframe in BM are provided by GNET. The clock signals extracted by GCTN are firstdriven by CKV, and then transmitted to the boards in BTS interface frame throughexternal HW clock cables.

    4

  • 7/30/2019 05-troubleshooting for clocks.doc

    5/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    II. Introduction to theinput reference source signals in BSC clock frame

    There are three channels of input reference source in BSC clock frame.

    1) 8kHz differential signal source from E3M (including 8kHz0

    and 8kHz1)

    8kHz0 and 8kHz1 are two sets of 8kHz reference source, most commonly used byBSC. They can be input to GCKS by JC1 or JC2 through differential cables (twistedpairs).

    The cable connection is illustrated in Figure II.1. The 8kHz differential signal sourcesfrom the trunk system are input by the 4-core sockets JC1 and JC2. Note that JC1and JC2 are connected in parallel, i.e., if the two channels of 8kHz differential signalsources from the trunk frame are input from one 4-core connector, the differentialcables can be connected either to JC1 or JC2.

    8k0-8k0+

    JC1JC2

    8K1-

    8K1+

    Figure II.1 The cable connection when the 8kHz differential reference sources come from the same

    trunk frame

    If the two channels of 8kHz differential signal sources come from different trunkframes, the cable connection must be handled with care. Only two differential cablescan be connected to either 4-core sockets, as shown in Figure II.2.

    8k0-

    8k0+

    8k1-

    8k1+

    JC1JC2

    Figure II.2 Cable connection when the 8kHz differential reference sources come from different trunk

    frames

    2) The 2.048Mbit/s (E1 signals and HDB3 codes are converted on GCKS to

    2.048MHz clocks) input reference source (including ER1 and ER2) from BITS

    equipment

    3) The 2.048MHz TTL clock signal input reference source (including 2MR1 and

    2MR2) from BITS equipment

    5

  • 7/30/2019 05-troubleshooting for clocks.doc

    6/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    III. Introduction to the output signals in BSC clock frame

    1) To GSNT: 8kHz, 32MHz

    2) To GCTN: 8kHz, 32MHz and 4MHz

    Note:

    8kHz and 32MHz clock signals are simultaneously output to the backplane of GSNTand that of GCTN, with the output matching resistance as 75 (150 for each board).The 4MHz signals only output to the GCTN, with the output matching resistance as75. Therefore, set the frequency meter to the state of low resistance matching whentesting the 8kHz, 32MHz and 4MHz clock signals with the meter. Otherwise, the testresult might be inaccurate.

    IV. Introduction to BSC clock hardware configuration

    1) Introduction to GCKS

    GCKS is the board that generates the reference clock source in the clock system ofthe switch. In the board, there is a stratum-2 Oven voltage Control Oscillator(OCXO) inGCKS. GCKS traces the external reference signals and filters their jittering anddrifting to ensure high frequency accuracy and stability of the timing signals outputand provide the switch a high-quality clock source. The GCKS can provide bothstratum-2 and stratum-3 clocks.

    GCKS works under four modes. When GCKS is first powered on, the OCXO in it willhave been heated for 3 minutes. In the 3 minutes, its MOD indicator is OFF. Then, theboard starts to work, its OCXO enters free-run state and the MOD indicator is OFF. Ifthere is no reference source, the OCXO will continue in its free-run state. If there isreference source, GCKS will first check its frequency deviation. If the deviation is big,REFA indicator will be ON. If the deviation is normal, the OCXO will enter fast pull-in

    state and the MOD indicator will flash quickly. Usually fast pull-in state will last 10~15minutes. After the 10~15 minutes, if the reference source is abnormal, the OCXO willenter free-run state. If the reference source is normal, the OCXO will enter lockedstate, MOD indicator will flash slowly and GCKS starts to work. If the referencesource is abnormal during the locked state, the OCXO will enter holdover state andMOD indicator will be ON. But when the reference source resumes normal, theOXCO will re-enter locked state.

    2) Important DIP switches

    (a) Configuration of GMPU and GCKS communication rate

    There are DIP switches on both GCKS and CKB for configuration of communicationbetween GCKS and GMPU. Only when the DIP switches on both GCKS and CKB arecorrectly set, can the communication between GMPU and GCKS be normal.

    Otherwise, GCKS fault will occur.

    Table 1.1 The DIP switches for configuring the communication rate between GCKS and CKB

    BSC type GCKS

    S5.1

    CKB

    S4.1 S4.2 S4.3 S4.4

    Communication mode

    Multi

    module

    OFF ON ON ON ON Point to multi-point, high

    baud rate

    Single

    module

    ON OFF OFF OFF OFF Point to point, low baud rate

    6

  • 7/30/2019 05-troubleshooting for clocks.doc

    7/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    7

  • 7/30/2019 05-troubleshooting for clocks.doc

    8/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    (b) Other DIP switches on GCKS

    There are other two DIP switches on GCKS for configuring the clock stratum andphase lock mode of GCKS. Usually they are set as follows.

    DIP switch Common setting in BSC Description

    S5.2 ON ON: PDH phase lock mode

    OFF: SDH phase lock mode

    S5.3 ON ON: stratum-3 clock

    OFF: stratum-2 clock

    3) Indicator on GCKS

    Indicator Color and normal

    state

    Meaning and description

    RUN Red, flashing once

    every second when the

    communication is

    normal.

    The RUN indicator flashes once every second when the

    communication is normal, 4 times every second when the

    communication is abnormal. The normal communication depends

    on the correct settings of the DIP switches. GCKS communicates

    with SLT or ALM with low baud rate when there is an SLT in the

    clock frame or there is a clock frame in the independent C&C08B

    standalone exchange. If the RUN indicator flashes quickly after

    GCKS is powered on, first check the DIP switches on the GCKS.

    ACT Green ON when the GCKS is active and OFF when the GCKS is standby.

    F0 Green, OFF when the

    reference source is

    normal

    Indicator for the status of the external reference source selected.

    ON when the reference source is abnormal, On when the

    reference source is normal, flashing when the software is re-

    capturing the reference source, OFF again when the reference

    source is locked. If F0 is ON after GCKS is powered on, check to

    ensure the reference source is correctly accessed to the GCKS.

    There can be six types of reference source to be accessed. Seen

    from the back of the backplane, J1 and J2 are the input terminals

    for 2048kbit/s reference source, J3 and J4 are the input terminals

    for 2048kHz reference source. Under locked state (MOD indicator

    flashes slowly. Refer to the description below), when F0 indicator

    flashes, GCKS is re-capturing the reference source and it will be

    OFF again after it locks the reference source. If F0 flashes

    frequently, check if SDH mode is required. For F0 flashing under

    other modes, check the quality of the reference source accessed.

    F1 Green, OFF when the

    board works normally

    OFF when the system works normally (including VCXO, DDS,

    88915). If F1 on the GCKS is ON, GCKS fault occurs (including

    VCXO, DDS AND 88915 fault). Normally GCKS will be switched

    over automatically (if it is standby, no switchover will be

    8

  • 7/30/2019 05-troubleshooting for clocks.doc

    9/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Indicator Color and normal

    state

    Meaning and description

    performed). Maintenance personnel shall replace the faulty board

    timely according to the status of other indicators.

    LOF Green, OFF when the

    board works normally

    ON when the 88915 is out of lock. Under this case, the board will

    be automatically switched over (if it is standby, then no switchover

    will be implemented). Due to 88915 out-of-lock, the clock signals

    (frequency and amplitude) output from the board will be abnormal,

    so the maintenance personnel shall replace the board timely.

    DDS Green, OFF when DDS

    output is normal

    OFF when DDS output is normal, ON when the DDS components

    on GCKS work abnormally. When DDS is ON, automatic

    switchover of the GCKS shall occur (if the board is standby, no

    switchover will occur). The abnormal DDS components will make

    the clock signals output by the board abnormal (frequency and

    amplitude). DDS output abnormal is most probably caused by the

    inaccuracy of the reference source. Therefore, first check the

    reference source. If the reference source is normal, replace the

    board timely.

    LOCK Green, OFF when

    88915 is normal

    ON when 88915 is out of lock.

    The meaning of LOCK indicator is completely the same as that of

    LOF indicator.

    CLK Green, OFF when58274 is normal

    OFF when the time chip 58274 has calibrated the time and worksnormally. Otherwise, it flashes. The time chip 58274 in the

    C841CKS provides time to the switch, but the initial time shall be

    configured on the BAM. CLK indicator is OFF when 58274 works

    normally. If no initial time has been configured at the BAM, or

    58274 chips work abnormally, CLK indicator will flash once every

    second.

    R8K0 Green,ON when R8K0

    is selected

    The 8kHz reference source from the trunk. There are altogether 6

    reference source indicators on C841CKS. When the external

    reference source is selected, its corresponding indicator will be ON.

    Otherwise, the corresponding indicator will be OFF. R8K0 is default

    reference source with highest priority (unless other reference

    source has been configured with higher priority than R8K0 on the

    BAM). As long as R8K0 is available, it will be configured as the

    default reference source. If it is unavailable, select R8K1 as the

    default reference source. By analog, the rest can be selected as

    the default reference source when all the reference sources before

    it in numbering are not available. If the active reference source is

    not available after GCKS is powered on, F0 indicator will be ON

    and the indicator for the active reference source will also be ON

    9

  • 7/30/2019 05-troubleshooting for clocks.doc

    10/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Indicator Color and normal

    state

    Meaning and description

    (R8K0 by default). If stratum-3 clock is configured for GCKS (by

    setting SW3.5 as ON or configuring it on the GMPU), GCKS can

    capture suitable reference source as active. Its stratum-2 clock will

    be configured by the GMPU. The active reference source states

    (normal or abnormal) are indicated by F0.

    REFA Green, OFF when the

    clock deviation is

    normal

    ON when the clock deviation is too large and OFF when the clock

    deviation is normal. REFA indicates the clock deviation when the

    clock is under holdover or free-run state, and it indicates the output

    of clocks under fast pull-in or locked state.

    REFA will be ON when the output frequency deviation is bigger

    than 0.4ppm or 4.6ppm respectively under the case that stratum-2

    clock or stratum-3 clock is configured to GCKS. Only when the

    GCKS is in locked state, That frequency deviation check would be

    performed to the reference source. If the deviation is detected too

    big, GCKS will enter holdover state, and it returns into locked state

    when the reference source resumes normal.

    MOD Green OFF: free run (just powered on/the reference source is abnormal

    after fast pull-in)

    Flash quickly: fast pull-in (quickly lock the reference source)

    Flash slowly: locked (normal)

    ON: holdover (the reference source is abnormal after being locked)

    +12V Green, ON when the

    12V power supply is

    normal

    12V power supply indicator. OFF when it is normal. +12V is the

    power supplied to the OCXO on GCKS. If the 12V power supply is

    abnormal, there will be no output from the OCXO and the GCKS

    cannot work normally.

    V. Introduction to BSC clock data configuration

    Table 1.1 Tables required to be configured for BSC clocks

    Table name Function

    [Clock description table] Describes the clock source of the GNET

    [AM_CKS clock configuration table] Describes the work mode selection of the clock

    module

    For multi-module BSC, the two tables in the above table are required for BSC clockdata configuration.

    [Clock description table] configuresthe clock source of GNET. For multi-module BSC,

    10

  • 7/30/2019 05-troubleshooting for clocks.doc

    11/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    select hardware selection (module B/C2K network) and select clock frame clock (Bindependent office) for C&C08B standalone exchange BSC.

    [AM_CKS clock configuration table] configures the stratums and reference sources ofthe clock.

    [Select clock reference source]

    There are 3 categories, 6 types of clock reference sources, i.e., 8kHz differentialsignals 8K0 and 8K1, 2Mbit/s E1 signals 2MB0 and 2MB1, 2MHz TTL signals 2M0and 2M1. Usually 8kHz differential signals are used. Generally all are selected.

    [Configure the priority of the reference source]

    Usually the priority level for reference source selection from higher to lower is 8K0,8K1, 2MB0, 2MB1, 2M0 and 2M1. Generally all are selected.

    [Select the active clock after power on]

    Select the GCKS first used after the clock frame is powered on. Usually the activeGCKS0 is firstly selected.

    [Set clock stratum]

    For GCKS combines the stratum-2 and stratum-3 clocks, this parameter is designed.Usually stratum-2 is selected for MSC and HLR, and stratum-3 for BSC.

    [Set clock phase lock mode]

    Select the PDH mode.

    [Select clock module work mode]

    Usually automatic adjustment mode is selected. Controlled mode is selected only forcommissioning and clock network access acceptance test.

    VI. Troubleshooting for BSC clocks

    1) Check indicators on GCKS

    Note especially the state of MOD and REFA indicators during the normaloperation of GCKS. If the MOD indicator flashes slowly, it means GCKS istracing normally the MSC clocks. If the MOD indicator is OFF, it means theGCKS is working under free-run mode (usually the free-run mode is not takenunless when the frequency deviation of the clock reference source obtained fromMSC is too big). If the MOD indicator is in the states other than ON and OFF, itmeans the GCKS is working abnormally. In addition, if the REFA indicator is ON,it means the frequency deviation of the GCKS output clock is too big. Check the

    status of F0 indicators. If the F0 indicator is ON, it means the reference source isabnormal. If the F0 indicator is OFF, it means the reference source is locked. Ifthe F0 indicator is flashing, it means the software is now tracing the referencesource. When CLK indicator is ON, it means there is communication faultbetween GCKS and GMPU.

    2) Query on the maintenance console

    (a) Query whether GCKS is faulty or abnormal on the maintenance console.

    (b) Query the state of the clock source by selecting the menu [Controloptions/ /GCKS Board Control/Query Clock Source State]

    Select the menu above to query the state of the clock source. Note that thefrequency deviation queried on the maintenance console is not accurate enough.

    11

  • 7/30/2019 05-troubleshooting for clocks.doc

    12/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Therefore, usually the average value of multiple frequency deviations queried onthe maintenance console is taken for reference.

    (c) Query the work state of GCKS by using the right-key menu on themaintenance console.

    3) Query clock-related alarms on the alarm console

    Query whether there are clock-related alarms on the alarm console, such asClock reference source abnormal, Clock configuration data error, BTS 8kHzclock alarm, 13MHz clock out of lock, DDS control data abnormal, Clockreference source switchover and GCTN clock fault alarm etc.

    4) Check related components with meters

    The most commonly used test instrument for clocks is frequency meter. Thecommonly used frequency meter is HP53132A, used to measure the frequencyaccuracy. Oscillometer is used to check whether the waveforms of the clocksignals are deformed and whether the phases are normal.

    Clock test can be performed at MSC side, BSC side and BTS side. Refer to theBSC clock test point below for clock test accuracy requirement. Usually the clocktest follows a process below.

    5) First test whether the clocks output from the BSC clock frame are accurate.

    6) If the BSC clocks are accurate, test the clocks at BTS side.

    7) If the BSC clocks are not accurate, test the clock at MSC side.

    8) If the clock at MSC side are also inaccurate, test the clock reference source of

    MSC.

    9) If the MSC clocks are accurate, test whether there are faults on the clock

    transmission path between MSC and BSC.

    VII. BSC clock test point

    1) Output 2MHz clock in GCKS

    Test instrument: frequency meter

    Test point: 2MH-OUT test point on the backplane of the clock frame, J16 in the

    Figure 1-4. This is the most commonly used clock test point and it exists in the

    clock frame of both MSC and BSC.

    Grounding point: coaxial shield layer of the clock frame can be used as the

    grounding point.

    Test requirement:

    Stratum-2 clock is adopted at the MSC side and its clock accuracy should bef/f1E-8.

    Stratum-2 clock is adopted at the BSC/BTS side and its clock accuracy shouldbe f/f5E-8.

    Therefore, the frequency deviation allowed at the MSC side is 2048000.000 1E 8 = 0.02Hz.

    And the frequency deviation allowed at the BSC/BTS side is 2048000.000 5E 8 = 0.1Hz.

    If there is too big frequency deviation, check whether the reference source,GCKS and CKB are normal.

    12

  • 7/30/2019 05-troubleshooting for clocks.doc

    13/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    See Figure VII.1 for 2MHz test point.

    8K0-8K0+8K1-8K1+

    2MH-OUT1

    8K-IN

    JC1JC2

    J16

    Figure VII.1 2MHz clock output from the backplane of the clock frame

    2) 8kHz reference source accuracy on the CKB of the clock frame

    Take the 8kHz clock reference source as the example.

    Test instrument: Frequency meter

    Test point: It depends on the reference source selected, as shown in Figure 1-5.

    Grounding point: The GND point in Figure VII.2 is recommended, or the coaxial

    shield layer of the clock frame can also be used as the grounding point.

    Test requirement:

    The allowed frequency deviation of the 8kHz reference source at the MSC sideis 8000.000 1E 8 = 8 1E 5 Hz

    The allowed frequency deviation of the 8kHz reference source at the BSC/BTS side is

    8000.000 5E 8 = 4 E 4 Hz

    Figure VII.2 Test point for 8kHz clock reference source on CKB

    3) Clock test at the back of MSM

    Test instrument: Oscillometer

    Test point: As shown in Figure VII.3, connect the oscillometer on the upper part

    of pins at the back of MSM on TCB to test the 8kHz, 2MHz and 4MHz clocks.

    Grounding point: The GND points in Figure VII.3 are recommended.

    13

  • 7/30/2019 05-troubleshooting for clocks.doc

    14/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Test requirement: The waveform is normal.

    In addition, to test the accuracy of the 8kHz clock reference source, lead the MSM TxE1 cables to the test TMU to test the 2MHz clocks extracted by the TMU. Theaccuracy requirement is the same as that in testing the clocks at the back of CKB.

    Pin in Up Socet of MSM Backplane

    2M-2M+

    4M-4M+

    8K-8K+

    25

    26

    27

    A B CGND

    GND

    GND

    Figure VII.3 MSM clock signal test point

    4) Clock accuracy at the back of GCTN

    Test instrument: Oscillometer

    Test point: As shown in Figure VII.4, connect the oscillometer on the upper part

    of pins at the back of the backplane of corresponding GCTN to test the 8kHz,

    32MHz and 4MHz clocks (two groups for each).

    Grounding point: The grounding points in Figure VII.4 are recommended.

    Test requirement: The waveform is normal.

    32M132M0

    8k 18k 0

    4M14M0

    45

    46

    47

    A B CGND

    GND

    GND

    Pin in Up Socet of CTN Backplane

    Figure VII.4 Test points for the clock signals on the backplane of GCTN

    5) GSNT clock accuracy

    Test instrument: Oscillometer

    Test point: As shown in Figure VII.5, connect the oscillometer on the back of

    14

  • 7/30/2019 05-troubleshooting for clocks.doc

    15/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    backplane of corresponding GSNT to test the 8kHz and 32MHz clocks (two

    groups for each).

    Grounding point: The GND points in Figure VII.5 are recommended.

    Test requirement: The waveform is normal.

    SNT Backplane

    8k 0

    8k 1

    32M0

    32M1

    4

    34

    35

    A B C

    GND

    Figure VII.5 Test points for the clock signals on the backplane of GSNT

    5.2.2 Fundamental Knowledge of BTS Clock System

    BTS clock system performs radio link time division and radio frequency calibration

    function in GSM system. It plays an important role in the normal serviceimplementation of GSM system.

    I. BTS reference clock

    When BTS clock reference source comes from BSC, the BTS is connected to the BIEof the BSC through the E1 cables of the BIU (BTS Interface Unit). BIU selects andprocesses one channel of clocks among the clocks extracted from E1 interface line,then takes it as the reference clock for the MCK module of the BTS high-precisionclock. Under some cases, BIU can also provide the input for the external referenceclocks. It selects one channel of clocks from the two channels of clocks it extractsfrom the E1 as the reference source clock for MCK module. The deviation of the clockis required to be no more than 0.05ppm.

    II. BTS system clock

    The OXCO, frequency divider, frequency verification unit, CPU and D/A in the MCKmodule comprises a closed-loop frequency calibration system to automatically tracethe reference source input and provide the BTS high-performance 13MHz referenceclock, as shown in Figure II.1.

    15

  • 7/30/2019 05-troubleshooting for clocks.doc

    16/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Reference sourceCPU D/A OCXO System clock

    Frequency division

    System clockPhase discrimination

    Figure II.1 MCK module phase-locked loop

    All clock signals used by the BTS are generated by the 13MHz signals. MCK modulecan decide the precision of the external reference signals, automatically pull in andlock the reference clock signals and filter their jittering so that the clock signals outputcan have high frequency precision and stability and can work under free-run orholdover state when the external reference clock source gets lost.

    There are two BTS clock software versions currently in service, V 0407 and V0529.Their algorithms are not the same.

    For V0407, when the phase discrimination deviation is less than 4Hz, the clocks will

    trace and lock the reference clock. Otherwise, they will not trace and lock thereference clock and they stay in free-run mode.

    For V0529, the clocks always trace and lock the reference source.

    MCK module has three phase lock states, free-run, pull-in and locked.

    Free-run state occurs under the following scenarios:

    When the reference source jitters terribly and cannot stay stable for the clocks to

    pull in.

    When the reference source gets lost, MCK will enter free-run state immediately

    no matter what state it is in.

    13MHz clock out-of-lock alarm will be reported under both the above scenarios. When the reference source is set as the internal clock on the local MMI, the MCK

    module will be forced into free-run state.

    Pull-in state occurs under the following scenarios.

    When the reference source jittering is less than 4Hz (BTS3X) or 5Hz

    (BTS3001C) under free-run state, MCK module will enter pull-in state.

    When the clock deviation frequently exceeds the security range under the locked

    state, MCK module will enter pull-in state.

    The locked state occurs under the following scenarios.

    The 13MHz clock deviation has been less than 0.2Hz for long time; the MCK module will enter locked state.

    III. The generation of BTS system clock signals

    GSM system is a TDMA (Time Division Multiple Access) system, i.e., the multipleaccess function is accomplished through time division. Both the TDMA principle andGSM05.10 specification regulate that four signals are required for the timing at theradio interfaces, FCLK (Frame Clock), FN (Frame No.), TSCLK (Timeslot Clock) andOBCLK (Octet bit clock).

    As defined in GSM specification, system clock signals can be generated through thefrequency division of the master clock of 13MHz. Among the clock signals, OBCLK is

    the sixth frequency division of the 13MHz, i.e., 136=2.16MHz. The FCLK, OBCLK

    16

  • 7/30/2019 05-troubleshooting for clocks.doc

    17/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    and SREF signals are aligned with the rising edge of the 13MHz clocks (10-20 nsdelay allowable).

    SREF: Frequency 13MHz/4=3.25 MHz, period 307.7 ns, duty ratio 50%

    OBCLK: Frequency 13MHz/6=2.167 MHz, period 461.5 ns, duty ratio 50%

    FCLK: Frequency 13MHz/6/10000=216.7Hz, period 4.615 ms, duty ratio 50%

    13MHz: Frequency 13MHz, duty ratio 50%

    The period relationship between clocks of different systems is as the following:

    1 FCLK=8TSCLK

    1 TSCLK=156.25 BCLK=1250 OBCLK

    IV. The calibration of 13MHz clocks

    Because the frequency dispersion of the 13MHz OCXO is rather large in actualmanufacturing, the 13MHz output frequencies of different boards differ greatly.Therefore, to ensure an accurate 13MHz reference clock for each board, all the13MHz clocks are required to be calibrated respectively before the boards start towork. In addition, the 13MHz clocks are required to be calibrated once every year toavoid the 13MHz clock deviation due to clock aging.

    1) Required equipment and environment

    One frequency meter, one serial port communication cable and MMI BTSmaintenance system.

    2) 13MHz clock calibration process

    Check to ensure the board is in normal service (warm-up end). Connect the

    frequency meter to the board 13MHz clock port, and the serial port

    communication cable to the MMI BTS maintenance system control console.

    Start MMI control, obtain administration authority and complete the board

    configuration.

    Select board management and clock configuration item.

    Select Internal clock in clock configuration interface, adjust the default DA

    control value so that the difference between the 13MHz value on the frequency

    meter and the actual 13MHz is controlled within 0.1Hz.

    Select store to Flash Memory and press in the [CLK configuration]

    interface.

    Note: Press Ctrl + Alt + F to perform clock hardware parameter configuration.

    Exit the configuration item and complete the 13MHz clock calibration.

    The clock system principles for all Huawei BTS series are basically the same. Toget a comprehensive understanding of Huawei BTS clock system signal flow canhelp a lot for clock system troubleshooting.

    V. Huawei BTS clock system signal flow

    1) BTS30 clock system signal flow

    17

  • 7/30/2019 05-troubleshooting for clocks.doc

    18/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    BTS

    TDU

    Board

    JP3

    JP4BTS JP2

    JP1 JP3

    JP3

    TRB

    CMB

    U5

    U7

    U6

    U8

    U2

    U4

    U1

    U3

    SIX TRX

    Matching

    TMU

    Wring2

    Wring1

    Wring3

    Wring4

    Figure V.1 BTS30 clock system signal flow

    BTS30 clock system signal flow is illustrated in Figure 5-10. The path in the major

    cabinet is TMU CMU (JP3) TDU (JP2) TDU (JP4 and JP3 Extension

    cabinet) JP1TRB (JP3) 6 TRXs in the local cabinet. During the path, signals

    might pass four wiring points: wiring 1 and wiring 2 (to the extension cabinet), wiring 3(TDU to TRB) and wiring 4 (from the CMB of the major cabinet to the TDU).

    The path in the major cabinet is TDU (JP3 or JP4) TDU (JP1) TRB (JP3) the

    6 TRX in the local cabinet. During the path, signals might pass three wiring points:wiring 1 and wiring 2 (to the major cabinet and next level of extension cabinet), wiring3 (to TDU and TRB).

    The signal flow of BTS312 is similar to that of BTS30. Clock signals are forwarded viaTDU.

    2) BTS3001C clock system signal flow

    Because BTS3001C cabinets are encapsulated and not allowed to be opened in thefield, only clock source and operation problems, no internal signal flow, are describedhere.

    VI. Board indicators of BTS series

    1) Indicators of clock-related boards in BTS3X series

    Table 1.1 TMU indicator

    Indicator Color Meaning Description Normal state

    PLL Green Phase

    discrimination

    indicator

    ON: free run

    Flash quickly (4 Hz): pull-in

    Flash slowly (1 Hz): locked

    OFF: abnormal

    Flash slowly (1 Hz)

    2) BTS3001C clock-related indicator

    There is no clock-related indicator in BTS3001C.

    18

  • 7/30/2019 05-troubleshooting for clocks.doc

    19/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    VII. Huawei BTS series clock test points

    1) BTS3X series

    The T2MHz and 13MHz test output in TMU is illustrated in Figure VII.1.

    PWR

    RUN

    LI3

    LI1

    LI2

    M/S

    PLL

    DBG

    MMI

    LI4

    T2M

    FCLK

    T13M

    Figure VII.1 TMU clock test point

    2) BTS3001CBTS3001C test points are illustrated in Figure VII.1. The 13MHz output point is13MCLK, and FCLK output point is 2M (output shift is performed by executingcustom commands).

    19

  • 7/30/2019 05-troubleshooting for clocks.doc

    20/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    13MCLKFCLK

    SLAVE

    SLAVE

    MASTER

    IOPOWER

    MMI

    ASUO&M

    PWRRUNACTMODLIU

    S3

    ONOFF

    MSB

    LSB

    Figure VII.2 BTS3001C O&M cavity (REV.C)

    5.2.3 Specifications about BTS Clock System

    The requirement about GSM BTS frequency accuracy in GSM specifications is as thefollowing.

    The frequencies of radio part and baseband part of the BTS must derive from thesame signal source. For BTS of any type, no matter whether they support slow rateFH (Frequency Hopping), the absolute frequency error of their transceivers and therelative frequency error between transceivers must be less than 0.05ppm under alltest conditions.

    5.3 Trouble Handling

    5.3.1 Trouble Handling for BSC

    I. Trouble handling for reference source

    1) Description

    F0 indicator is ON or flashing after GCKS enters normal service. Clock referencesource abnormal and Reference source replacement alarms are displayed on thealarm console. Sometimes most of the BTSs clock are out of lock.

    2) Introduction to indicators

    F0 indicator indicates the state of the reference source.

    OFF: Reference source unavailable and GCKS in free-run state

    Flash quickly: Reference source available, GCKS in fast pull-in state for about half anhour.

    Flash slowly: GCKS in locked state (normally working state)

    ON: Reference source gets lost when GCKS is in locked state, GCKS enters holdoverstate.

    3) Analysis

    Remove the cables for the 8K0 and 8K1 reference sources from E3M and check

    if there are alarms related to reference source and if the BTS has locked the

    clocks of BSC.

    20

  • 7/30/2019 05-troubleshooting for clocks.doc

    21/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    If after the cables are removed, reference source alarms disappeared and theBTS normally locks the clocks of BSC, reference source fault can be confirmed.

    If there is frequency meter available, test the deviation of the output 2MHz clocks

    in the clock frame before the cable removal and after the cable removal. If theoutput clock deviation is large before the cable removal, but normal after the

    removal, reference source fault can be confirmed.

    Check board indicator

    When F0 indicator is ON, no reference source is available. When F0 is flashing, thereference source is not stable.

    4) Handling process

    If the reference source fault is confirmed, take the following steps for troubleshooting.

    Check whether the cables are correctly and reliably connected. Note that 8K0

    and 8K1 come from different offices and are connected to different sockets (JC1

    and JC2). IF possible, replace clock input cables to remove the problems caused

    by the clock input cable fault.

    Check the clock generation channels in E3M and TCSM frame. Connect the

    clock access cables to other E3Ms and TCSM frames to check whether there is

    E3M or TCSM frame fault. If there is, check whether the E3M interfaces are

    damaged or whether TCSM frame is not in normal service. Replace E3M or the

    DRC on the back of the backplane.

    If the reference source fault still cannot be removed, test in sequence the MSC

    CKS output clock, MSM clock and the 8kHz reference source clock input from

    the BSC CKB. If the MSC clocks are not accurate, check the reference source and the

    operating status of the clock frame of the MSC.

    If the MSM clock is not accurate, check the E1 cables between BSC and MSC. Ifthere is transmission between BSC and MSC, the transmission exerts great impacton the clocks and has to be tested.

    II. Trouble handling for the clock frame

    1) Components of the clock frame

    The clock frame is composed of GCKS, CKB and PWC. There are two GCKSs,

    working in active/standby mode in slot 4 and slot 6.2) Description

    On the maintenance console, GCKS is displayed red and GCKS indicator worksabnormally. Clock-related alarms are displayed on the alarm console.

    3) Analysis

    The most probable causes for clock frame fault is GCKS or CKB fault (including DIPswitches error).

    When the above scenario occurs, if the fault is removed after GCKS replacement,check whether the DIP switches are correctly set. If the DIP switches are correctlyset, it can be confirmed that the GCKS is faulty. Replace the corresponding GCKS.

    After GCKS replacement, if the fault still exists, remove the cables for the two

    21

  • 7/30/2019 05-troubleshooting for clocks.doc

    22/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    reference sources in the clock frame and test the CKB output clock (including 2 MHz,4 MHz, 8 kHz and 32 MHz). If the CKB output clock is abnormal (the waveform of thefault is difficult to obtain and the sampling will be long by using oscillometer), CKBmust be faulty. Replace CKB.

    III. Trouble handling for the cables

    1) Clock-related cables

    (a) Maintenance cables

    Maintenance cables are used to connect GMCCM and GCKS. GMCCM performsO&M to the two GCKSs through 2 serial ports.

    One end of the maintenance cable is connected to JB33 on C821MCB (it is insertedfrom the first pin on the top). Another end of the cable has two connectors, one 4-coreconnector and one 2-core connector. The 4-core connector is connected to JB21 onCKB (inserted in the pins five pins above the bottom) and the 2-core socket is

    connected to JB3 on CKB (inserted from the first pin on the top).

    (b) Clock cables

    There are two types of clock cables. One is the clock cable for synchronization(differential), which is connected to the fifth port at the back of E3M and inputssynchronization clock source to the clock frame. Another is the clock cable used totransmit the two sets of clocks (32MHz, 8kHz and 4MHz; 32MHz and 8kHz) output bythe clock frame to the GCTN and GSNT via corresponding backplane.

    2) Analysis

    On the maintenance console, GCKS is displayed red, GCKS CLK indicator flashesslowly and Clock reference source alarm is displayed on the alarm console. Thetrouble cannot be removed even after GCKS replacement. The F0/REFA indicator on

    the GCKS is ON, and it might indicate reference source cable fault. GCTN clockfault and GSNT clock fault alarms might be displayed on the alarm console, but noother correlated alarms occur.

    3) Handling process

    When GCKS is displayed red, GCKS CLK indicator flashes slowly and the troublecannot be removed after GCKS replacement, replace the maintenance cables.

    When Clock reference source fault alarm is reported and the F0/REFA indicator onGCKS is ON, the reference source cables might be faulty. Replace the referencesource cables.

    When GCTN clock fault and GSNT clock fault alarms, but no correlated alarm, aredisplayed on the alarm console, the CKB output clock cable might be faulty. Replace

    the CKB output clock cable.

    5.3.2 Troubleshooting for BTS

    I. Troubleshooting for the reference source

    1) Description

    Alarms 13MHz clock out-of-lock, BTS BSIC cannot be unlocked and the cellhandover success rate drops, but no other alarms, are reported.

    2) Probable causes

    22

  • 7/30/2019 05-troubleshooting for clocks.doc

    23/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Refer to Table 1-2.

    3) Handling process

    Step 1 On the local MMI maintenance console, check whether the BTS MCK module

    clock is in free-run state or fast pull-in state. Observe and record the D/A value in theboard information displayed.

    Step 2 Test and record the jittering deviation of the 2MHz output clocks in differentBTSs. The jittering deviation within a short time frame should be in the MCK moduletracing range, i.e., within +/-5Hz or +/-4Hz.

    Note that custom messages for clock signal switchover has to be sent through thelocal MMI maintenance console before the test of 2MHz output clocks in BTS3001C.

    D4-00-FF-FF-FF-81-00-FF-02-72- [00-FCLK, 01-2MHz]

    Step 3 Test the BTS 13MHz output clocks and write down the value.

    Step 4 If the BTS 13MHz output clock is not accurate, set the BTS clock mode as

    internal clock mode. Adjust the BTS D/A value to enable the BTS enter locked stateaccording to the deviations of the 13MHz clocks.

    Step 5 If BTS 13MHz output clock is accurate, 13MHz clock out-of-lock might becaused by the reference source fault, which probably is incurred by transmission orBSC clock fault.

    Step 6: Check whether 13MHz clock out-of-lock occurs to other BTSs of the sameBSC. Check whether the 2MHz clock of the BSC is accurate and normal.

    Step 7 If the BSC clock is accurate, check whether other TS abstraction equipmentexist on the transmission channel and whether the transmission equipment clocksystem is normal.

    II. Troubleshooting for field operation errors

    1) Description

    The alarms 13MHz clock out-of-lock alarm, BTS BSIC cannot be unlocked, Cellhandover success rate drops, but no other alarms, are displayed.

    2) Probable causes

    Refer to Table 1-2.

    3) Handling process

    Step 1 On the local MMI maintenance console, right click the MMU and observewhether the clock state in the board information displayed is free-run. Write down the

    D/A value displayed.

    Step 2 Set the BTS clock mode as the internal clock mode, test the 13MHz clockoutput by the BTS with the frequency meter and observe whether the 13MHz outputmeets the specification requirement.

    Step 3 If errors occur to the 13MHz clock output by the BTS, manually adjust the D/Avalue and observe whether the 13MHz output clock varies accordingly.

    Step 4 If D/A value can be successfully adjusted, it can be confirmed that the errors ofD/A value are causes by BTS clock aging or operation mistakes. Re-adjust the D/Avalue corresponding to the 13MHz BTS.

    If the adjustment of D/A value cannot according adjust the 13MHz output frequency,boards must be faulty. Replace the boards.

    23

  • 7/30/2019 05-troubleshooting for clocks.doc

    24/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    Detailed troubleshooting measures: under the internal clock mode, adjust the D/Avalue so that the BTS can output accurate 13MHz clocks and save the D/A value inthe Flash Memory of the BTS. Then reset the BTS clock work mode as the externalclock mode.

    III. Troubleshooting for cables

    1) Description

    Clock-related alarms and phase-locked loop alarm occur to the TRXs in all the slots.

    Repeated loading, TRX communication alarm and removal report occur to the TRXsof all slots.

    No alarms occur to TMU.

    TDU indicator and DIP switches are normal.

    2) Probable causes

    Refer to Table 1-2.

    3) Analysis

    Instrument required: multimeter

    Step 1 According to the BTS30 clock system signal flow, check the rack cabling fromthe transmission source (the TMU in the major BTS) to TRB. Replace the faultycables if there is any, and observe whether the troubles have been removed.

    If the troubles cannot be removed, it might be caused by board fault. Remove theboard fault accordingly.

    IV. Troubleshooting for board fault

    1) Description

    Boards are repeatedly reset and loaded due to TMU major clock alarm, TRX frameNo. (TS No.) alarm and clock alarm etc.

    TMU alarm and TRX alarm are most probably caused by board fault.

    As described in the BTS30 clock system signal flow, TMU is the source of the clocksystem, CMB, TRB and TDU are the parts the clock signal flow passes and the TRXis the termination of the clock signals.

    Therefore, TMU, TDU and CMB clock faults will lead to the abnormal working of allTRXs. The TMU fault alarm will be accompanied by TMU clock alarm

    Therefore, when TMU, TDU and CMB clocks are faulty, all TRXs cannot worknormally. TMU fault is usually accompanied with TMU clock alarm, TDU fault will leadto the fault of all TRXs and CMB fault will also lead to TDU fault.

    When TRB and TRX are faulty, usually clock alarms occur to the TRXs in some slots.

    Usually board faults can be analyzed and located according to the system clocksignal flow.

    2) Probable causes

    Refer to Table 1-1.

    3) Handling process

    There are two ways to handle board faults. One is board replacement. Another is

    24

  • 7/30/2019 05-troubleshooting for clocks.doc

    25/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    clock waveform test. The second way requires oscillometer on site to help the test.Test the clock wave form segment by segment according to the clock signal flow tolocate the faulty segment.

    The following describes the process for board replacement.

    Step 1 Check whether all TRXs are faulty and whether serious clock alarms occur toTMU.

    If yes, go to Step 2.

    If No, go to Step 7.

    Step 2 Replace the board suspected to be faulty with a normal board and observewhether the BTS can normally working.

    If the BTS can resume normal working, it can be confirmed that TMU is faulty.Replace the faulty TMU.

    If after TMU replacement, TMU major clock is removed, but TRX alarm cannot, go toStep 3.

    Step 3 Observe whether the configuration of the rack indicated by TDU indicator iscorrect. If yes, replace the faulty TDU with a normal TDU working in other racks andobserve whether the fault is removed. If yes, go to Step 4.

    Step 4 It can be confirmed that cabling fault is excluded.

    Step 5 Replace CMB.

    Step 6 Replace TRB.

    Step 7 If faults of some TRXs still cannot be removed, pull put the faulty TRXs andinsert them into normally-working TRX slots. Observer if faults still persists. If yes, the

    TRX must be faulty. If no, TRB corresponding slot or matching problem might happen.Replace TRB boards.

    For matching problem, pull out, then push in connectors to adjust the clock bus loadso that the fault can be removed.

    5.4 Examples

    5.4.1 Troubleshooting Examples for BSC Clock Fault

    I. Call drops during handover due to too large BTS clock frequency

    deviation

    Description

    Sometimes the call dropped during handover in GSM1800 system. But the signallevel was high and there was no interference.

    Handling process

    The maintenance personnel found that the BTS frequency deviation was very bigaccording to the onsite test result. The 13MHz output frequency deviation of someBTSs reached 2.5Hz, greatly larger than the international standard 0.65Hz. 8KHZ

    clock alarms of many BTSs were reported on the alarm console. MSC frequently

    25

  • 7/30/2019 05-troubleshooting for clocks.doc

    26/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    reported Clock software phase lock normal/abnormal alarm, which indicated theinaccuracy of the clock at MSC side.

    Analysis

    From the above description, it can be inferred that the instability of BTS clock werethe major causes for call drops during handover. Therefore, the maintenancepersonnel re-adjusted the clock reference source of the MSC to make it stable, the8kHz input clock error alarm disappeared and the call drop during handoverdisappeared.

    II. BTS clock frequency deviation too big due to configuration error in the

    clock description table

    Description

    In single module BSC, the maintenance personnel queried the MCK clock of the BTSand found its the frequency deviation was very big. Then tested the clock from theGCTN and found its frequency deviation was also very big.

    Handling process

    The maintenance personnel queried the data configuration and found the clockselection in the clock description table wad configured as Multi-module BSC clockload-sharing mode and the GCTN extracted clocks from GOPT.

    Analysis

    In the single module BSC, the clock selection should be configured as C&C08Bstandalone exchange and the GCTN extracted clocks directly from the clock frame.After modifying the configuration, the maintenance personnel tested the clocks fromthe GCTN and found their frequency deviation very small. They queried the MCK

    clocks and found the frequency deviation normal.

    III. Clock fault due to cable problem from MCB backplane to FIO backplane

    Description

    During the equipment check after an upgrading in an office, the maintenancepersonnel found clock system alarms were reported and the ENA indicator on GCTN0in SCP4 was flashing quickly.

    Handling process

    The maintenance personnel at first thought it was caused by GCTN fault. But the faultcould not be removed after GCTN replacement. They performed GCKS switchoverand the system resumed normal. They then replace GCKS0 and switch GCKS0 overas active, but the fault still remained. After repeated verification, it was found thatwhenever GCKS0 is used, the alarm would be reported. But when the GCKS1 wasused, the system would work normally. The maintenance personnel performed GSNTswitchover clock cable plug/unplug test and inserted only one GCKS in the frame, butthe fault could not be removed.

    Analysis

    In the internal cable set of the BSC, the cable from MCB to FIO backplane isdisrupted, so GCTN cannot correctly select clocks after clock switchover.

    26

  • 7/30/2019 05-troubleshooting for clocks.doc

    27/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    IV. BSC clock problem due to MSM fault

    Description

    In an office, BTS2.0 was used. After BTS cutover, most of the BTSs were in fast pull-in state and crystal oscillator override alarm was reported many times.

    Handling process

    The maintenance personnel queried BSC clock board and found it normal. The MODindicator of GCKS was flashing slowly and GCKS was in locked state. They checkedall the boards on the BSC maintenance console and found their state normal.

    Analysis

    After analyzing the faulty MSM, the maintenance personnel found that the matchingresistance of the E1 Rx/Tx chip of the faulty MSM is damaged. They replaced thedamaged resistance and the fault was removed.

    V. BTS out of lock because E1 TS integrater cannot transmit the clock in

    real time

    Description

    In a BSC module, 13MHz clock out-of-lock alarm was displayed at the BTS side.The TMUs of all the BTSs were in free-run state and could not lock BSC clocks.

    This fault can be temporarily removed by resetting GCKS but cannot be removedfrom its root cause.

    Handling process

    The maintenance personnel checked the E1 channels on E3M 2. They connected TScrossover equipment in one E1 channel. They replaced the clock extraction E1 port ofthe BSC and extracted the clocks from the E1 that did not pass the TS crossoverequipment. The out-of-lock problem of the BTS was removed and the BTS started totrace its upper level clock.

    VI. The reference source not available due to too small amplitude of 8k1

    reference source

    Description

    After XX BTSs cutover, most of the BTSs were found in fast pull-in state and crystaloscillator override alarm was reported many times. The maintenance personnel

    checked the BSC clocks and found them normal. They then checked MSC clocks andfound the 8kHz 1 reference source abnormal.

    Handling process

    The maintenance personnel tested the 2MHz differential signals output from the MSMon the pins at the back of the MSM backplane with an oscillometer and a frequencymeter. The square wave pulse voltage was only 68 mV and the frequency was onlyaround 2.048MHz.

    Analysis

    The fault was probably caused by too small signal level. After tested with thefrequency meter, it was 1.75MHz. After MSM replacement, the clocks resumed

    normal. Therefore, it can be inferred that the fault was caused by MSM problem.

    27

  • 7/30/2019 05-troubleshooting for clocks.doc

    28/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    VII. Clock fault due to CKB DIP switches setting error

    Description

    During batch GCKS replacement in the office X, the GCKS of the older versionworked normally in the slot 6 of the clock frame. But it was displayed faulty after beingreplaced with the GCKS of the new version.

    Handling process

    The maintenance personnel checked the DIP switches on CKB and found the S4 wasincorrectly set as ON ON ON OFF. Therefore it was the S4 setting error that causedthe abnormal working of new-version GCKS in slot 6.

    Analysis

    Under multi-module BSC, the communication between GCKS and GMCCM adoptspoint to multi-point mode. Since the serial port on GCKS0 in slot 4 in the clock frameis directly connected to the serial port cables communicating with GMCCS, the settingof the DIP switches exerts impact on the serial port communication of GCKS1 in slot6 instead of that of the GCKS0 in slot 4 in the clock frame.

    VIII. Clock fault due to connection problem of clock cables and the

    backplane

    Description

    In XX local network, there was no voice when calls were connected, and Group0clock fault alarm was reported to GCTN in AM/CM (Group0 clock refers to the clocksignals transmitted from GCKS0 to GCTN or to GSNT. Group1 clock refers to theclock signals from GCKS1 to GCTN or to GSNT).

    Handling process

    The maintenance personnel pulled out the active GCKS0 and performedactive/standby switchover to the boards. Then the network worked normally.

    Analysis

    After test, it was confirmed that the fault was caused by the clock cable connectionproblem between the CKB and the group0 4MHz clock cable of GCTN 0. Replace theclock cable and the CKB, the fault can be removed.

    5.4.2 Troubleshooting Examples for BTS Clock Fault

    I. Clock fault because TMU13MHz clock cannot lock th external clock

    Description

    In office deployment, The maintenance personnel found that the BSIC of A BTS couldnot be unlocked and the TMU of BTS A was in free-run state. In the BSCconfiguration data, the working state of BTS A was set as Tracing BSC clocks, butthe actual state was free-run. The D/A value of TMU OXCO was 1470.

    Troubleshooting process: The maintenance personnel tested the T2MHz and T13MHzoutput of the BTS TMU with a frequency meter and found the deviation of the twoclocks was very big, as given in the following.

    28

  • 7/30/2019 05-troubleshooting for clocks.doc

    29/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    T2MHz 2047996Hz 2048006Hz

    T13MHz 12999993Hz 12999994Hz

    From the above test result, the clock deviation of the T2MHz was very big and it was

    necessary to check whether it was poor transmission quality or the TMU 21Q554 chipproblem that caused the clock deviation.

    The maintenance personnel selected a BTS B that was working normally in externalclock mode, and then they tested the output of the T2MHz and T13MHz clocks withthe frequency meter.

    T2MHz 2047999Hz 2048000Hz

    T13MHz 13000000Hz 13000000Hz

    They switched the TMU of the BTS B to the BTS A and tested the clock output ofTMU with a frequency meter.

    T2MHz 2047993Hz

    2048009HzT13MHz 13000000Hz 13000000Hz

    From the above test, it can be confirmed that the transmission of the BTS B was notstable and the clock deviation was big. But the TMU of BTS B could still lock theexternal clocks in BTS A and output standard 13MHz clocks. Therefore, though thetransmission quality was poor, it was not the cause for the free-run state of the TMUin BTS A.

    After switching the TMU of BTS A back, they adjusted the D/A value of the OXCO withthe frequency meter. They found that the TMU could output standard 13MHz clocksand successfully locked the external clock when the D/A value was 1910.

    Analysis

    The following three conclusions can be drawn from the troubleshooting process.

    1) The transmission quality of BTS A is poor, but it is not the cause for the problem

    that the TMU cannot lock the external clock.

    2) The chips of the TMU in BTS A are not damaged, because the TMU can work

    normally when the D/A value is 1910.

    3) The root cause for the fault is that the deviation between the setting of the D/A

    value of the OXCO in the TMU of BTS A and the actual value is too big (1910-

    1470=440).

    The maintenance personnel had traced the status of the TMU in BTS A for three

    weeks and found the value of the phase discriminator stayed around 1910 and theTMU worked normally. This means the fault has been removed.

    II. Faults are located segment bu segment accoriding to the signal flow

    Description

    In site X, TRX could not be started normally.

    Troubleshooting process: The maintenance personnel powered off the BTS, thenproceeded in the following procedures.

    1) Replaced the connection cable between CMBJ25 and TRBJC3. But the TRX still

    could not be started.

    29

  • 7/30/2019 05-troubleshooting for clocks.doc

    30/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    2) Replaced the TRB and the TRX could be started. But, master clock alarms were

    reported during the operation.

    3) Checked the DIP switches, the cables and the matching connectors of the TDU,

    CMB and TRB and found no error.

    4) Pulled out, then pushed in all TRXs one by one, and powered on them. But the

    fault could not be removed.

    5) Replaced TMU and reset the BTS X. The fault disappeared.

    6) Re-installed the replaced TMU and the master clock alarm occurred again.

    Therefore, it can be confirmed that the TMU was faulty.

    7) Replaced the faulty TMU with the normal one and tested the BTS X. The

    operating status of boards was normal.

    Analysis

    The BTS worked normally after TMU was replaced and master clock alarm occurredto the original TMU. From the fact, it can be inferred that the TMU fault caused theTRX unable to be started normally.

    III. Clock fault due to operation errors

    Description

    13MHz clock out-of-lock alarm was found in many BTSs in X area.

    Troubleshooting process: The maintenance personnel configured the 13MHz clockunder free-run mode at the local end and tested the output T13M of the BTS. Theyfound the output deviation was around 5Hz. They adjusted the D/A value and foundthe 13MHz clocks working normally under free-run mode. They then configured theclocks of the BTS under Tracing the upper level clock mode and found the BTSnormal without any out-of-lock alarm.

    Analysis

    The fault was caused by operation errors. The default clock D/A value on the clockO&M interface was 2048, while the D/A value adjusted for the boards was between1100 and 1600. When the user queried the interface and pressed to exit theinterface, the system would start clock capturing with the default D/A value. Under thiscase, the output of the 13MHz clocks was around 13MHz+5Hz, 5Hz deviated from theex-factory 13MHz. The version of many clocks in the BTS in the field was 0407,which usually gave up clock capturing of the reference clocks 4Hz deviated from thevalue of the 13MHz phase discriminator and adopted free-run clock mode. Thus, the

    13MHz clock out-of-lock alarm was reported.

    IV. Troubleshooting example 1 for faulty TMU

    Description

    In the BTS in X area, TRX repeatedly loaded the software, TRX communicationalarm, TRX micro-processor fault and frame TS alarm was also reported.

    Troubleshooting process: The maintenance personnel checked the output signalpulse of the 13MHz clocks of the TMU and found them intermittently disruptive. Theyreplaced the TMU and the BTS resumed normal.

    Analysis

    30

  • 7/30/2019 05-troubleshooting for clocks.doc

    31/31

    Troubleshooting ManualM900/M1800 Base Station Subsystem

    Chapter 5 Troubleshooting for Clock

    TMU was damaged and 13MHz clocks were unstable.

    V. Troubleshooting example 2 for faulty TMU

    Description

    In X local network, the TRX stayed in downloading state after BAM reset. There werehistory alarms such as 2166 TRX master clock alarm and 2136, test phase-lockedloop alarm, the clock of the TMU was in slave state, and to rest the TMU and TRXfrom the remote end failed.

    Troubleshooting process: The maintenance personnel found that the transmission atthe local end was normal and the ALM indicator on the TRX was ON. He performeddebugging on the MMI and found there was no reset hole beside the RST silk print onthe handle bar. He first mistaken that the RST hole was covered by the yellow ESDlabel. But, he then found that the clock of the TMU was a slave clock and the softreset cannot be performed. On the local end, there was master clock alarm and E1local end alarm, and the TRX was still in alarm state after hard reset of TMU at thelocal end and the TRX repeatedly downloaded software. He replaced the TMU andthe BTS resumed normal.

    VI. Troubleshooting examples for BTS3001C version fallback

    Description

    The cell handover success rate of BTS3001C microcell in X area drops sharply.

    Troubleshooting process: The maintenance personnel tested the 13MHz clock outputdeviation of the BTS with a frequency meter and found it reached around 27Hz. Hechecked the version of the BTS and found the version of the BTS fell back from05.0301A to BOOT 03.0301A. He re-activated the software and the fault disappeared.

    Analysis

    After version fallback, the versions of the BTS are not matched, so deviation of theBTS clocks occurs.