31
C C hapter 3 hapter 3 Atomic Emission Spectroscopy Atomic Emission Spectroscopy 3.1. Fundamentals of AES 3.2. Instrumentation 3.3. Analytical Methods of AES 3.4. Control of Analytical Interferences

Chapter 3 atomic emission spectroscopy

Embed Size (px)

Citation preview

Page 1: Chapter 3 atomic emission spectroscopy

CChapter 3 hapter 3 Atomic Emission SpectroscopyAtomic Emission Spectroscopy

3.1. Fundamentals of AES

3.2. Instrumentation

3.3. Analytical Methods of AES

3.4. Control of Analytical Interferences

Page 2: Chapter 3 atomic emission spectroscopy

3.1. Fundamentals of AES

Atomic Emission Processes

Page 3: Chapter 3 atomic emission spectroscopy

3.2. Instrumentation

1. Light source 2. Spectrometer3. Detector 4. Readout

Page 4: Chapter 3 atomic emission spectroscopy

1. Light Source

Type Eva.Temp. Exci. Temp. stability Application.

DC Arc high low poor Qualitative Analysis

AC Arc mid mid good Qualitative Analysis

Spark low highest good Quantitative Analysis

ICP highest high best Quantitative Analysis

Page 5: Chapter 3 atomic emission spectroscopy

Light Source Progresses

Page 6: Chapter 3 atomic emission spectroscopy
Page 7: Chapter 3 atomic emission spectroscopy
Page 8: Chapter 3 atomic emission spectroscopy
Page 9: Chapter 3 atomic emission spectroscopy

2. Spectrometer

⑴Monochromater Optical-direct Read Spectrometor

⑵Polychromater Optical-direct Read Spectrometor

Page 10: Chapter 3 atomic emission spectroscopy
Page 11: Chapter 3 atomic emission spectroscopy
Page 12: Chapter 3 atomic emission spectroscopy

3. Detector

⑴Spectrograph

⑵Photomultiplier Tube

⑶Segmented-array Charge-Coupled

Detector(SCD)

Page 13: Chapter 3 atomic emission spectroscopy
Page 14: Chapter 3 atomic emission spectroscopy

4. ICP-AES Instrumentation System

Page 15: Chapter 3 atomic emission spectroscopy
Page 16: Chapter 3 atomic emission spectroscopy
Page 17: Chapter 3 atomic emission spectroscopy

Two-dimensional array produced by the echelle mount

Page 18: Chapter 3 atomic emission spectroscopy
Page 19: Chapter 3 atomic emission spectroscopy
Page 20: Chapter 3 atomic emission spectroscopy

Fig 3-16 Scheme of SCD Detector

Page 21: Chapter 3 atomic emission spectroscopy

3.3 Analytical Methods of AES

1. Qualitative Analysis

⑴Standard Iron Spectra Comparison

⑵Indicate Element Spectra Comparison

⑶Determination of Line Wavelength

Page 22: Chapter 3 atomic emission spectroscopy

2. Quantitative Analysis

Quantitative Formula

⑴theoretical Formula of AES

ne

gI i

kTuululul

E

x

x

ZhvA

u

11

1

neg

vhAI ikTul

ululul

E

x

x

Z

u

11

bi can

(3.1)

(3.2)

(3.3)

Page 23: Chapter 3 atomic emission spectroscopy

⑵Lomakin Formula

Internal Standard Methods⑶

Standard Calibration Methods⑷

bACI

bx

bxb

ss

x

s

x KCCCA

A

I

IR

KCbR lglglg

(3.4)

(3.5)

(3.6)

Page 24: Chapter 3 atomic emission spectroscopy

3.4. Analytical Interferences

1. Spectrum Interference

2. Background Interference

3. Matrix Interference

Page 25: Chapter 3 atomic emission spectroscopy

1. Spectrum Interference

Page 26: Chapter 3 atomic emission spectroscopy

2. Background Interference

Page 27: Chapter 3 atomic emission spectroscopy
Page 28: Chapter 3 atomic emission spectroscopy

3. Matrix Interference

Page 29: Chapter 3 atomic emission spectroscopy
Page 30: Chapter 3 atomic emission spectroscopy

3.5 Sensitivity and Detection Limit

1. Detection limit

ss

CR

LD3

.. (3.7)

Page 31: Chapter 3 atomic emission spectroscopy