6
31 PPE - CPE / Arc Flash Protection PPE - CPE Fire-retardant clothing in case of exposure to an electric arc, confirming to IEC 61482-2 and the regulation NFPA 70E. PROTECTION AGAINST ARC FLASH The following are used to determine the proper equipment for protecting against an electric arc: • The maximum fault current value. • The phase/ground rated voltage at the site of the risk. • The distance between the source of the arc and the reception surface. • The AC cycle number and the mono or three-phase circuit type. • The location where the arc is produced (confined space). After recording these parameters, we can estimate the level of risk and determine the proper protective clothing and PPE to use: 12 to 100 cal/cm 2 or class 1 or 2. For more information, please contact our technical department. The "Arc Flash" phenomenon. An electric arc follows a short circuit. It produces nearly instant effects with serious consequences without proper protection. Arc Flash Protection the solution for complete electric arc protection - The arc's main manifestation is its thermal effect. The heat energy released, which is proportional to the voltage, intensity, and fault length, can be considerable (19.000°C), melting the metal and charring the insulation. - Blast effect, caused by the very rapid release of energy in a limited volume of air (similar to an explosion). - Light effect with high ultraviolet and infrared radiation. - Ionisation effect that can trigger an arc on nearby active sections. When electric arc danger exists, heat-resistant clothing must be worn. The arc's characteristics are given by: • The resistance value of the free arc, expressed in cal/cm 2 according to NFPA 70 E, ASTM standards, and IEC 61482-1-1. or • The protection class (1 or 2) with a constrained arc according to IEC 61482-1-2. mm Dimensions kg Weight

CATU Arc Flash Protection Clothing Brochure

Embed Size (px)

Citation preview

Page 1: CATU Arc Flash Protection Clothing Brochure

31PPE - CPE / Arc Flash Protection

PPE - CPE

Fire-retardant clothing in case of exposure to an electric arc, confirming

to IEC 61482-2 and the regulation NFPA 70E.

PROTECTION AGAINST ARC FLASH

The following are used to determine the proper equipment for protecting against anelectric arc:• The maximum fault current value.• The phase/ground rated voltage at the site of the risk.• The distance between the source of the arc and the reception surface.• The AC cycle number and the mono or three-phase circuit type.• The location where the arc is produced (confined space).

After recording these parameters, we can estimate the level of risk and determinethe proper protective clothing and PPE to use: 12 to 100 cal/cm2 or class 1 or 2.

For more information, please contact our technical department.

The "Arc Flash" phenomenon.An electric arc follows a short circuit. It produces nearly instant effects with seriousconsequences without proper protection.

Arc Flash Protectionthe solution for complete electric arc protection

- The arc's main manifestation is its thermal effect. The heat energy released, which is proportional to the voltage, intensity, and fault length, can be considerable(19.000°C), melting the metal and charring the insulation.

- Blast effect, caused by the very rapid release of energy in a limited volume of air (similar to an explosion).

- Light effect with high ultraviolet and infrared radiation.- Ionisation effect that can trigger an arc on nearby active sections.

When electric arc danger exists, heat-resistant clothing must be worn.The arc's characteristics are given by:• The resistance value of the free arc, expressed in cal/cm2 according to NFPA 70 E,

ASTM standards, and IEC 61482-1-1.or• The protection class (1 or 2) with a constrained arc according to IEC 61482-1-2.

mmDimensions kg Weight

Jack Nottidge
T&D.com Stamp
Jack Nottidge
T&D.com Stamp
Page 2: CATU Arc Flash Protection Clothing Brochure

32PPE - CPE / Arc Flash protection

Arc Flash protection

Nomex III ® Undergloves100% Nomex III® fire-resistant and heat-resistant undergloves. Protects the hands against heat of up to 100°C. Ideal protection for "arc flash" equipment.

High performance synthetic Nomex III ® fibre.

Reference

CG-37

Characteristics

One size 32Includes 5 pairs

EN 407EN 420

Fire protection.

g

Jack Nottidge
T&D.com Stamp
Page 3: CATU Arc Flash Protection Clothing Brochure

33PPE - CPE / Arc Flash equipment

PPE - CPE

Arc Flash equipment

"Arc flash" face shield kit(12 cal/cm2)

1.5

MO-187

MO-182/1-B

M-87413

Reference KIT-ARC-01

1 Face shield with chin cup 12 cal/cm2, absorbs> 99.9% of harmful UV radiation,

70% light transmission, tested to ASTM F 2178specifications

1 ABS helmet electrically insulated EN397, EN 50365, ANSI Z89.1 20kV.

1 carrying bag for face shield and helmet

NFPA 70E

ATPV 20 Cal/cm2

IEC 61482-1-1IEC 61482-1-2 Classe 2

ElectricianABS helmet.

Large fieldof view.

Chin protection

Anti UV and polycarbonate1.5 mm thickness.

"Arc flash" Helmet (20 cal/cm2)The only one all integrated helmet with "arc flash"faceshield on the market.

NFPA 70E

CharacteristicsReference

MO-180-ARC Integrated helmet with "arc flash" Faceshield 1.2

"Arc flash" coverall double zipperProtects against the thermal hazards of an electric arc. Easy to put on.

CharacteristicsReference

MV-105(*) Ultra soft 1.4

Composition

RetractableFaceshield highvisibility& UV Protection.According toNFPA 70EASTM F 2178IEC 61482-2IEC 61482-1-1IEC 61482-1-2class 2GS-ET 29

Mechanical & Electrical Protection helmetEN 397EN 50365

Double zipper along the entire length.

Light, compact and flexible protection in Arc rated fabricASTM F1959ASTM F1506

IEC 61482-2

NFPA 70E

(*) to complete by size M, L ou XL. Other sizes on request.

kg

kg

kg

Total length g WeightPackaging

Jack Nottidge
T&D.com Stamp
Page 4: CATU Arc Flash Protection Clothing Brochure

34PPE - CPE / Arc Flash equipment

Arc Flash equipment

(*) Reference to be completed by the size M, L or XL.Size S to 3 XL on request.

*1 For reference KIT-ARC-12-C-(*).*2 For reference KIT-ARC-12-C-(*).*3 For reference KIT-ARC-12-J-(*).

Blue jacket 3/4with 12 cal/cm2.

Protectivehood12 cal/cm2.

Safety glasses.

Coverall 12 cal/cm2.

Reference Characteristics

KIT-ARC-12-C-(*) *1

KIT-ARC-12-J-(*) *2

KIT-ARC-12-JP-(*) *3

Coverall

Long hooded jacket

Short jacket withouthood + pants

Capacity cal/cm2

12 cal/cm2

12 cal/cm2

12 cal/cm2

4.2

3

4.4

IEC 61482-2 NFPA 70E

Made of ultra soft ®

confortable and light.

"Arc flash" jacket and protective coverall kits (12 cal/cm2)

Made of Indura ultra soft ®

confortable and light.

Carrying bagfor the kit.

kg

Face shield on electrician helmet

MO-187

MO-182/1-B

MO-11000

MO-134

M-87413

M-87295

1 Face shield with chin cup 12 cal/cm2, absorbs> 99.9% of harmful UV radiation, tested to

ASTM F2178 specifications

1ABS helmet electrically insulated EN397, EN 50365, ANSI Z89.1, 20kV.

1 safety glasses EN 166/EN 170

1 arc flash protective hood (12 cal/cm2), only with coverall and blue short jacket.

1 protective coverall 12 cal/cm2 *1 , ASTM F1506 and NFPA 70E Standards or1 arc flash protective jacket 12 cal/cm2, ASTM F1506 and NFPA 70E Standards.

1 carrying bag for face shield and helmet.

1 all kit carrying bag.

Composition of KITS

Jack Nottidge
T&D.com Stamp
Page 5: CATU Arc Flash Protection Clothing Brochure

35PPE - CPE / Arc Flash equipment

Arc Flash equipment

PPE - CPE

MO-182/1-B

MO-11000

M-87295

KIT-ARC-25-B-(*) *1

KIT-ARC-40-B-(*) *2

KIT-ARC-65-B-(*) *3

KIT-ARC-100-B-(*) *4

Carrying bagfor the kit.

Arc Flash protectivehood with face shield, 40 cal/cm2. Electrician helmet.

Arc Flash Dungarees, 40 cal/cm2.

Safety glasses.

Arc Flash Jacket, 40 cal/cm2.

IEC 61482-2 NFPA 70E

"Arc flash" protective kits (25, 40, 65 or 100 cal/cm2)

Reference Capacity cal/cm2

25

40

65

100

6

6.9

8

8

KAKI

GREY

CAMEL

CAMEL

Color

Composition of KITS

M-881968 *1

M-881961 *2

M-881976 *3

M-881979 *4

1 arc flash protective hood with an integrated

face shield 25 *1, 40 *2, 65 *3 or 100 *4 cal/cm2,

ASTM F2178 and NFPA 70E Standards

1 ABS helmet electrically insulated EN397, EN 50365, ANSI Z89.1 20kV.

1 safety glasses EN 166/EN 170

1 arc flash protective bib overall 25 *1,

40 *2, 65 *3 or 100 *4 cal/cm2, ASTM F1506

and NFPA 70E Standards

1 arc flash protective coat 25 *1, 40 *2,

65 *3 or 100 *4 cal/cm2, ASTM F1506 and

NFPA 70E Standards

1 all kit carrying bag

KIT-ARC-40-B-(*)KIT-ARC-25-B-(*) KIT-ARC-65/100-B-(*)

kg

(*) Reference to be completed by the size M, L or XL.Size S to 3 XL on request.

*1 For reference KIT-ARC-25-B-(*).

*2 For reference KIT-ARC-40-B-(*).

*3 For reference KIT-ARC-65-B-(*).

*4 For reference KIT-ARC-100-B-(*).

kg Weight

Jack Nottidge
T&D.com Stamp
Page 6: CATU Arc Flash Protection Clothing Brochure

Knitted glove, 15 gauge, made oftexturized polyamide, blackcolour, black nitrilfoam coating onpalm and fingertips.

CG-951

36PPE - CPE / Workwear and other protections

2 flattened breastspockets closed by injected zips every plastic part hidden.

Workwear and other protections

Electrician coverallCoverall without metallic part, avoiding any flash hazards. 100% cotton.

CG-951 ManutentionActivities: Assembly, fitting, construction, maintenance and all building construction work.CG-952 Mechanical protection (cutting) Activities: Packaging, cutting, handling sharp and/or oily objects, stamping, automotive, aerospace, railway work, sharpening, all building and outdoor work.

Tape measure pocket on right back leg.

Neck jumper

Gusset back.

Front closed by injected zipevery plasticpart hidden.

2 flattened thighspockets.

Tape measurepocket onright back leg.

Reference

(*) Reference to be completed by the size,ex : MV-104/02.

36/38

40/42

44/46

48/50

52/54

56/59

60/62

64/66

MV-104/ (*)

Size

76/84

85/92

92/100

101/108

109/116

117/124

125/132

133/140

Chest size

00

01

02

03

04

05

06

07

Size forRef. (*)

Other Protection

Work Gloves

Reference

115

115

(*) Reference to be completed by the size of A, B, C or D.

A = 8

B = 9

C = 10

D = 11

One size

C = 10

CG-96-(*)

CG-97-C

Size

EN 388EN 420

CG-96-C

CG-97-C

American style gloves with very soft and flexible full bloom leather allowing full finger movement.

"Docker" style gloveswith very soft full bloomleather allowing full finger movement.

Semirigid red fabric top with elastic on the back.

3122

4544

4121

3122

g

Reference

Feeding fat and / or humid environment: installation,

adjustment, drawing, constructionand maintenance, wiring

and building work.

(*) Reference to be completed by the size of 07, 08, 09 or 10.

7 to 10

CG-951-(*)

CG-952-(*)

Size Use

Tightening elastic on theback of the hand.

Knitted glove, 13 gauge, made of cut resistant fibers, elasticated knitwrist,grey, with a black nonslip nitrilfoam coating on palm and fingertips.

CG-952

Jack Nottidge