37
ONT portfolio

ALU GPON TRAINING 3

Embed Size (px)

Citation preview

Page 1: ALU GPON TRAINING 3

ONT portfolio

Page 2: ALU GPON TRAINING 3

2

Objective

Upon completion of the module you will be able to

� list the functions and properties of a generic ONT

� describe the nomenclature used for the different ONT families

Page 3: ALU GPON TRAINING 3

3

Table of Contents

1.Overview

2.Data only ONTs

3. Data and Voice ONTs

4.Wireless ONTs

5.MDUs

6. Business ONTs

Page 4: ALU GPON TRAINING 3

4

Overview1

Page 5: ALU GPON TRAINING 3

5

Same ONT portfolio for all GPON platforms

7302 ISAM

7330 ISAM FTTN

7342 ISAM FTTU

Data Voice Business Wireless MDU

ALU ONT portfolio Other vendor’s ONT

ALU GPON Platforms

• All new ONT variants are supported on the FD platform

Page 6: ALU GPON TRAINING 3

6

7342 ISAM FTTU

Optical Network Terminations – Portfolio

The most comprehensive ONT portfolio in the market

Data only Voice & Data Wireless Business

MDU portfolio

Page 7: ALU GPON TRAINING 3

7

Subscriber interfaces

ONT

ResidentialGateway

STB(IP)

l * Ethernet

k * POTS

LAN

TV

PC

m * Coax

SIP phone

black phone

Page 8: ALU GPON TRAINING 3

8

ONT mnemonics

I -2 4 1 G Single

family

MDU

O – 00 24 0 V

Indoor

Outdoor

POTS Ethernet RF GigE (G),

HPNA (H)

Indoor

Outdoor

POTS VDSL, FE or

GigE ports

RF GigE (G), VDLSL

(V)

Business B – 0 4 0 4

Business POTS GigE ports RF E1 or T1

ports

Page 9: ALU GPON TRAINING 3

9

Battery backup option

� Uninterruptible power supply

• 220 VAC input

• 12/48 VDC output - low voltage

• eight hour, commercial battery backup

• visual status indicator

• hot swap batteries

� Wall mount inside home

• extends battery life

• compact size

• CE certified

� Battery status monitored

• battery low

• AC power failure

• battery condition

Page 10: ALU GPON TRAINING 3

10

Data only ONTs2

Page 11: ALU GPON TRAINING 3

11

Data ONT portfolio overview

Type Interfaces Mnemonic

I-010 1GE I-010G-P

I-010G-B

I-010G-Q

I-020 2x1GE I-020G-F

I-020G-M

I-020G-P

I-040 4x1GE I-040G-A

I-040G-B

I-040G-P

I-011 1x1GE + RF I-011G-A

Page 12: ALU GPON TRAINING 3

12

Data ONT: I-010G

Characteristics I-010G-B I-010G-P I-010G-Q

Enclosure and

size

13,7 x 11,1 x 3,7

cm14 x 10 x 3,5 cm

7,55 cm x 5,5 cm x 2,5

cm

Power

consumption5,04W / 5,59W 3W / 4W 33W / 4W

Benefits

GE at wire-speed, multicast across all ports, flex packet inspection/modification

Auto-negotiation and MDI/MDIX auto-sensing, multicast on GEM port, VLAN tag manipulation, classification and filtering

GPON media converter. Ultra small ONT with 1 Gigabit Ethernet drop

Troubleshooting

and diagnosis

RSSI, Connectivity

Fault

Management

RSSI

RSSI

Application Single family home, typically connected to a Residential Gateway (RGW)

Page 13: ALU GPON TRAINING 3

13

Data ONT: I-020G

Characteristics I-020G-F I-020G-M I-020G-P

Enclosure and size 16,5 x 13,5 x 2,3 cm 13,7 x 11,1 x 3,7 cm14 x 10 x 3,5 cm

Power consumption 3,7W / 4,7W 5,04W / 6,63W 3W / 5W

Benefits Used as demarcation point;

IP Video with multistage;

BW management per port per service

GE at wire-speed, multicast across all ports, flex packet inspection/modification

Auto-negotiation and MDI/MDIX auto-sensing, multicast on GEM port, VLAN tag manipulation, classification and filtering

Troubleshootingand diagnosis

RSSI, Connectivity Fault Management

RSSI, Connectivity Fault Management

RSSI

Application Residential users: single family home connected to Residential Gateway (RGW)

Enterprise or corporate users: Fiber to the desktop

Page 14: ALU GPON TRAINING 3

14

Data ONT: I-040G

Characteristics I-040G-A I-040G-B I-040G-P

Enclosure and size 16,5 x 13,5 x 2,3 cm 13,7 x 11,1 x 3,7 cm 13 x 17 x 3,3 cm

Power consumption 3,7W / 4,7W 5,04W / 7,9W 4,5W / 7W

Benefits Used as demarcation point;

IP Video with multistage;

BW management per port per service

GE at wire-speed, multicast across all ports, flex packet inspection/modification

Auto-negotiation and MDI/MDIX auto-sensing, multicast on GEM port, VLAN tag manipulation, classification and filtering

Troubleshootingand diagnosis

RSSI, Connectivity Fault Management

RSSI, Connectivity Fault Management

RSSI

Application Residential users: single family home connected to RGW

Enterprise or corporate users: Fiber to the desktop

Page 15: ALU GPON TRAINING 3

15

Data & RF ONT: I-011G

Characteristics I-011G-A

Enclosure and size 20,8 x 14,2 x 3,3 cm

Power consumption 4,75W / 8W

Benefits GE at wire-speed, multicast across all ports, flex packet

inspection/modification

ApplicationSingle family home with a Residential Gateway (RGW) and RF overlay for

video service

Page 16: ALU GPON TRAINING 3

16

Data and Voice ONTs3

Page 17: ALU GPON TRAINING 3

17

Data and Voice ONT portfolio overview

Type Interfaces Mnemonic

I-120 1xPOTS + 2x1GE I-120G-P

I-220 2xPOTS + 2x1FE I-220E-A

I-221 2xPOTS + 2x1FE + 1RF I-221E-A

I-240 2xPOTS + 4x1GE I-240G-A

I-240G-B

I-240G-P

I-241 2xPOTS + 4x1FE + 1RF I-241G-A

I-241G-B

I-241G-P

I-440 4xPOTS + 4x1GE I-440G-P

Page 18: ALU GPON TRAINING 3

18

Data and Voice ONT: I-120G

Characteristics I-120G-P

Enclosure and size 14 x 10 x3,5 cm

Power consumption 4,5W – 7W

Benefits Auto-negotiation and MDI/MDIX auto-sensing, multicast on GEM port, VLAN

tag manipulation, classification and filtering, multiple voice codex, CLASS

services, SIP, Megaco

Softswitch ALU 5020

ApplicationSingle family home with one analog phone and mulitple GigE service. Can be used with RGW to deliver IPTV.

Page 19: ALU GPON TRAINING 3

19

Data and Voice ONT: I-220E and I-221E

Characteristics I-220E-A and I-221E-A

Enclosure and size H:20,3 cm W:22,9 cm

Power consumption 4,5W / 7,6W

Benefits Echo cancellation,GR-909-CORE, loop start signaling, SIP based VoIP client

Softswitch FS 5K, Netcentrix, Metaswitch, Xener, Mitel, Centile, ALU 5020, Nortel

CS2K, Broadsoft

ApplicationSingle family home with two analog phone lines and GigE services. Can be used with RGW to deliver IPTV.

Page 20: ALU GPON TRAINING 3

20

Data and Voice ONT: I-24xG

Characteristics I-24xG-A I-24xG-B I-24xG-P

Enclosure and size 25,3 x 19,2 x 4,2 cm 20,8 x 14,2 x 3,3 cm 13 x 17,2 x 3,3 cm

Power consumption 14W typical 4,75W – 7,74W 4,5W-9W / 5,5W-12W

Benefits Echo cancellation,GR-909-CORE, loop start signaling, SIP based VoIP client

GE at wire-speed, multicast across all ports, flex packet inspection and modification

multicast on GEM port, VLAN tag manipulation, class. and filtering, multiple voice codex, CLASS services

Targeted Softswitch Broadsoft Broadworks,Mitel 3300 ICP, Centile, Surpass 4200

Nortel CS2K, ALU FS5K, Broadsoft, Mitel Centile, 5020 CSC, Nortel CS2K H.248, Broadsoft H.248, Surpass 4200 H.248

Stratus SIP

Application Deliver triple play services to single family home with analog POTs, GigE for HSI and optional RF video

Page 21: ALU GPON TRAINING 3

21

Data and Voice ONT: I-440G

Characteristics I-440G-P

Enclosure and size 13 x 17,2 x 3,3 cm

Power consumption 4,5W-9W / 5,5W-12W

Benefits multicast on GEM port, VLAN tag manipulation, class. and filtering, multiple voice codex, CLASS services

Target Softswitch Huawei Soft Ex 3000 H.248

Application Single family home with analog POTs and multiple GigEs

Page 22: ALU GPON TRAINING 3

22

Wireless ONTs4

Page 23: ALU GPON TRAINING 3

23

Wireless ONT portfolio overview

• Variants include RGW (layer 3) functionality

• IPTV over wireless is not supported

Type Interfaces Mnemonic

I-240W-P 2xPOTS + 4xGE I-240W-P

I-241W-P 2xPOTS + 4xGE + 1RF I-241W-P

I-241W-S 2xPOTS + 4xGE + 1RF I-241W-S

Page 24: ALU GPON TRAINING 3

24

Wireless ONT: I-241W-S (hosts Residential Gateway Application Module)

Characteristics I-240W-P

Enclosure and size 27cm x 19cm x 5 cm

Power supply 12V feed via external AC/DC convertor

Benefits L3-RGW & Wifi included (WEP +MAC filtering ); 802.11 b/g/n

support; SIP+H/248

Application Single family home with wireless internet access, analog POTS and

multiple GigE ports. Has an internal USB slot for added functionality

(RGAM) to enable the Connected Home.

Residential Gateway Application Module fits into USB slot at

top of ONTI-241W-S ONT

Page 25: ALU GPON TRAINING 3

25

Wireless ONT: I-240 Wireless

Characteristics I-240W-P

Enclosure and size 66mm x267mm x200mm (H x W x D)

Power supply 12V feed via external AC/DC convertor

Benefits L3-RGW & Wifi included (WEP +MAC filtering ); 802.11 b/g/n

support; SIP+H/248

Target softswitch Ericsson ICS 4.0 SIP

Application Single family home with wireless internet access, analog POTS and

multiple GigE ports.

Page 26: ALU GPON TRAINING 3

26

Wireless ONT: I-241 Wireless

Characteristics I-241W-P

Enclosure and size 66mm x267mm x200mm (H x W x D)

Power supply 12V feed via external AC/DC convertor

Benefits L3-RGW & Wifi included (WEP +MAC filtering ); 802.11 b/g/n support; SIP+H/248,

including RF overlay

Targeted softswitch Stratus SIP

Application Single family home with wireless internet access, analog POTS, multiple GigE ports and

RF video overlay.

Page 27: ALU GPON TRAINING 3

27

MDU (Multi Dwelling Unit)5

Page 28: ALU GPON TRAINING 3

28

MDU portfolio

Type Interfaces Mnemonic

O-00240 24xVDSL2 O-00240V-A

O-00240V-P

O-00240V-Q

O-00160 16xVDSL2 O-00160V-Q

O-8881 8xPOTS + 8xFE +8VDSL + 1xRF O-8881V-P

O-0881 8xFE +8VDSL + 1xRF O-0881V-A

Page 29: ALU GPON TRAINING 3

29

MDU: O-00240 VDSL

Characteristics O-00240V-A O-00240V-P or Q

Enclosure and size 43,8 x 24,5 x 4,4 cm 4,40 x 2,90 x ,66 cm

Power consumption 100 W (max) 56W (max)

Benefits VDSL profiles 30a/17a; in-building or in-

cabinet installation; sustained 100Mbps

per subscriber throughput, IGMPv2 and

IGMPv3

VDSL profiles 8d, 12a, 12b, 17a and 30a;

in-building or in-cabinet installation;

sustained 100Mbps per subscriber

throughput, IGMPv2 and IGMPv3; upstream

Power backoff

Targeted softswitch No voice ports No voice ports

ApplicationAddresses customers in apartments and multi-tenant buildings in cost-effective way by

reusing existing in-building copper

Page 30: ALU GPON TRAINING 3

30

MDU: O-00160 VDSL

Characteristics O-00160V-Q

Enclosure and size 4,40 x 2,90 x ,66 cm

Power consumption 33.6W (max)

Benefits VDSL profiles 8d, 12a, 12b, 17a and 30a;

in-building or in-cabinet installation;

sustained 100Mbps per subscriber

throughput, IGMPv2 and IGMPv3;

upstream power backoff

Targeted softswitch No voice ports

ApplicationAddresses customers in apartments and

multi-tenant buildings in cost-effective

way by reusing existing in-building copper

Page 31: ALU GPON TRAINING 3

31

MDU: O-8881

Characteristics O-8881V-P

Enclosure and size 410mm x300mm x160mm (H x W x D)

Power consumption 35,2 W : 12,8W + 2W/channel VDSL + 0,8W/channel act. POTS

Benefits VDSL profiles 30a/17a; up to 100Mbps simultaneous TX/RX; completely

silent, passively cooled; IGMPv2 and IGMPv3. POTS = SIP or H.248

Targeted softswitch ALU 5020 SIP

ApplicationAddresses customers in apartments and multi-tenant buildings or small

businesses, in cost-effective way by reusing existing in-building wiring

Page 32: ALU GPON TRAINING 3

32

MDU: O-0881

Characteristics O-0881V-A

Enclosure and size 40,6 x 30,3 x 15,3 cm

Power consumption 3,5W per user typically

Benefits VDSL profiles 30a/17a; 100Mbps simultaneous TX/RX; completely silent, passively

cooled; IGMPv2 and IGMPv3

Targeted softswitch (no voice ports)

ApplicationAddresses customers in apartments and multi-tenant buildings or small businesses,

in cost-effective way reusing existing in-building wiring

Page 33: ALU GPON TRAINING 3

33

Business ONTs6

Page 34: ALU GPON TRAINING 3

34

Business portfolio

Type Interfaces Mnemonic

B-0404 4xGE + 4xE1 B-0404-A

B-8112G 8xPOTS + 1xGE + 1xRF + 2xE1 B-8112G-A

B-8102G 8xPOTS + 1xGE + 2xE1 B-8102G-A

Page 35: ALU GPON TRAINING 3

35

Business Outdoor ONT

Characteristics B-8112G-A and B-8102G-A

Enclosure and size H:41,37 cm W:36,6 cm D:15,11 cm

Power consumption 10W typical, 24W maximum

Benefits Outdoor ONT can be placed on same PON serving residential customers.

E1 emulation using Circuit Emulation Service.

Softswitch Nortel CS2000, Broadsoft Broadworks, Mitel 3300 ICP, Centile

ApplicationSmall businesses requiring voice, GigE connectivity and optional RF video Mobile backhaul of wireless traffic

Page 36: ALU GPON TRAINING 3

36

Business Indoor ONT

Characteristics B-0404-A

Enclosure and size H:25,32 cm W: 19,21 cm D: 4.18cm

Power consumption 5.4W typical, 10W maximum

Benefits Indoor ONT can be used on same PON as residential customers. E1

emulation using Circuit Emulation Service.

Softswitch Broadsoft Broadworks, Nextone

ApplicationSmall businesses requiring voice and GigE connectivity Mobile backhaul of wireless traffic

Page 37: ALU GPON TRAINING 3

37

www.alcatel-lucent.comwww.alcatel-lucent.com