Laboratory Monitoring Systems Contronics Limited Greenfield Farm Estate Congleton Cheshire CW12 4TU Phone +44 (0) 1260 298 383 Fax +44 (0) 1260 298 387 [email protected] www.contronics.co.uk tron cs i n o c The Control Program can also display and print composite trend graphs showing all the sensors connected to any piece of equipment for any timeframe . . . The Control Program can sort the complete audit trail back to system switch-on by timeframe, event type, equipment, sensor and department . . . Alerter The Alerter is a pop-up application. It can be installed on any PC with access to the network. Users can configure the program to respond only to alarms from relevant departments. Alerter provides real time audible and visual indication of alarm conditions. The pop-up display mirrors the alarm information displayed on an InfoPoint. A remote user can accept alarms using the Control Program. The audit trail is maintained whether the alarm is accepted using the InfoPoint or the Control Program. Working together We work closely with our customers from the initial user requirement specification through to system acceptance. We can temperature map your equipment and provide documented justification for sensor positions. Our engineers will install, commission, calibrate and validate your system and train your staff. We will work with you to generate the qualification protocols you need to satisfy your regulatory requirements. Support you can rely on A one year, on-site, parts and labour warranty demonstrates our confidence in our systems. On-going maintenance agreements preserve your investment in Contronics systems. We look after preventative maintenance and scheduled annual calibration, validation and mapping and prepare a comprehensive documentation pack ready for your regulatory inspection. Specification Prolog Lite (with integral InfoPoint) Network connection Ethernet System capacity 25/50/100 sensors Channel configuration (max) 4 sensors + 4 contact inputs Database MySQL Audit trail + data log Back to commissioning Channel titles + alarm messages User configurable Alarm management Via InfoPoint or Control Program Off site alarms Email to on-call staff Mobile alert to smartphone UPS runtime 15 minutes Dimensions 385 x 375 x 75 (WxHxD) InfoPoint Network connection Ethernet Display 17” colour LCD 1024 x 768 SVGA resolution User interface Touch screen navigation with on-screen keyboard UPS runtime 15 minutes Dimensions 385 x 375 x 75 (WxHxD) DataNode (specification for 16 input DataNode) Network connection Ethernet Inputs 16 analogue 16 contact 4 serial Outputs 4 changeover relays Sensor types Temperature Relative humidity Oxygen depletion Carbon dioxide level Differential pressure Particle count Voltage/current input Door contact Panic button Motion detector Measurement resolution 0.1ºC or 0.1% full scale Measurement accuracy ±0.2ºC or ±0.2% full scale Log interval 1 to 99 minutes Stored data 1 week at 1 min log interval Alarm levels 4 Alarm delays 0 to 99 minutes UPS runtime 6 hours Dimensions 384 x 470 x 58mm (WxHxD) 9100QB0904

9001 qb0904 prolog lite (web version)

Embed Size (px)

Citation preview

Page 1: 9001 qb0904 prolog lite (web version)

LaboratoryMonitoring

Systems

Contronics LimitedGreenfield Farm EstateCongleton CheshireCW12 4TU

Phone+44 (0) 1260 298 383Fax+44 (0) 1260 298 387

[email protected] www.contronics.co.uk

tron csinoc

The Control Program canalso display and printcomposite trend graphsshowing all the sensorsconnected to any pieceof equipment for anytimeframe . . .

The Control Programcan sort thecomplete audit trailback to systemswitch-on bytimeframe, eventtype, equipment,sensor anddepartment . . .

AlerterThe Alerter is a pop-up application. It can be installed onany PC with access to the network. Users can configure

the program to respondonly to alarms fromrelevant departments.Alerter provides realtime audible and visualindication of alarmconditions. The pop-updisplay mirrors the alarminformation displayed onan InfoPoint.

A remote user can accept alarms using the ControlProgram. The audit trail is maintained whether the alarmis accepted using the InfoPoint or the Control Program.

Working togetherWe work closely with our customers from the initial userrequirement specification through to system acceptance.We can temperature map your equipment and providedocumented justification for sensor positions.

Our engineers will install, commission, calibrate andvalidate your system and train your staff. We will workwith you to generate the qualification protocols you needto satisfy your regulatory requirements.

Support you can rely onA one year, on-site, parts and labour warrantydemonstrates our confidence in our systems.

On-going maintenance agreements preserve yourinvestment in Contronics systems. We look afterpreventative maintenance and scheduled annualcalibration, validation and mapping and prepare acomprehensive documentation pack ready for yourregulatory inspection.

SpecificationProlog Lite (with integral InfoPoint)Network connection EthernetSystem capacity 25/50/100 sensorsChannel configuration (max) 4 sensors + 4 contact inputsDatabase MySQLAudit trail + data log Back to commissioningChannel titles + alarm messages User configurableAlarm management Via InfoPoint or Control ProgramOff site alarms Email to on-call staff

Mobile alert to smartphoneUPS runtime 15 minutesDimensions 385 x 375 x 75 (WxHxD)

InfoPointNetwork connection EthernetDisplay 17” colour LCD

1024 x 768 SVGA resolutionUser interface Touch screen navigation

with on-screen keyboardUPS runtime 15 minutesDimensions 385 x 375 x 75 (WxHxD)

DataNode (specification for 16 input DataNode)Network connection EthernetInputs 16 analogue

16 contact4 serial

Outputs 4 changeover relaysSensor types Temperature

Relative humidityOxygen depletionCarbon dioxide levelDifferential pressureParticle countVoltage/current input Door contactPanic buttonMotion detector

Measurement resolution 0.1ºC or 0.1% full scaleMeasurement accuracy ±0.2ºC or ±0.2% full scaleLog interval 1 to 99 minutesStored data 1 week at 1 min log intervalAlarm levels 4Alarm delays 0 to 99 minutesUPS runtime 6 hoursDimensions 384 x 470 x 58mm (WxHxD)

9100QB0904

Prolog Lite_18-12_Scanlog Leaflet 19/09/2012 17:45 Page 1

Page 2: 9001 qb0904 prolog lite (web version)

tron csinoc

Prolog LiteProlog Lite is the latest addition to our world-class range ofenvironmental monitoring systems. The system is 21CFR11Part 11 and GAMP compliant and will satisfy MHRArequirements. It is a multi-user system with the capacity tomonitor up to 100 points distributed over multiple sites. Itmonitors a complete facility whilst maintaining departmentalseparation and responsibility. Prolog Lite combines the serverand InfoPoint in a single, wall-mounted unit.

The server uses an industry standard MySQL database. Itstores the system configuration information and accumulatesmeasurements from DataNodes. It also maintains a secureaudit trail of alarms, alarm acceptances, settings changes andall system events and actions taken. Prolog Lite makesscheduled automatic database backups to a nominated serveron the network.

The system is highly resilient. Logged data is duplicated inthe database and in DataNode. If the network connection toDataNode is interrupted, missing database information will beautomatically retrieved when the network connection isrestored.

The system generates four alarms per sensor; upper and lowerwarning levels and upper and lower alarm levels.

Prolog Lite will send email containing detailed alarminformation to predefined addresses: including smartphones.Separate addresses can be defined for each department.

Departmental responsibility is achieved by configuringInfoPoint displays to respond only to alarms for specificdepartments.

As shown in the diagram above, Prolog Lite is connected by astandard Ethernet network to distributed DataNodes whichcollect and store data from local sensors. Local InfoPointsdisplay alarms and information only from equipment forwhich the department is responsible.

ProLog Lite software is being continuously developed toreflect the changing needs of users and to ensure that thesystem complies with current legislation and practice.Software updates are offered free of charge during warrantyand subsequent maintenance agreements.

InfoPointThe 17”, wall-mounted, colour LCD touch-screen display andintuitive user interface mean that InfoPoint is simple to use,easy to understand and minimises training.

InfoPoint displays alarm conditions, current sensor values andsettings, audit trail information and trend graphs.

Alarms can be accepted, channels can be inhibited andtemporary disables initiated (eg for defrost). All thefrequently used system operation and maintenance functionsare included.

InfoPoint uses an index card metaphor to simplify navigation.Touching the tab at the top of the screen changes the displaymode.

When an alarm occurs, InfoPoint generates an audible andvisual alarm, jumps to the alarm tab and displays the alarminformation and advisory text . . .

Username and password are necessary to accept alarms and auser comment is required for the audit trail. These areentered using the on-screen keyboard . . .

Sensor data is displayed graphically . . .

An image can beinserted on the statuspage to provide moreinformation . . .

InfoPoints can bedistributedthroughout a facilityas required and alarm notifications can be transferred to adifferent InfoPoint when a department is not staffed.

InfoPoint’s UPS ensures operation is maintained duringchangeover to emergency supply.

DataNodeDataNode accepts up to 16 analogue inputs, 16 contactinputs and 4 serial inputs. In addition, 8/4/2 analogue inputversions are available to minimise system cost for smallerapplications. The minimum logging interval is 1 minute.At this setting, DataNode stores 1 week of local data.

DataNode makes continuous analogue sensor measurementsat 1-second intervals and stores the worst excursion duringthe logging interval in the database. It accepts a range ofinputs as shown in the specification on the back page.The serial inputs interface with particle counters and otherintelligent sensors.

DataNode has 4 relay outputs. These can be configured tochange state for any combination of alarms and used, forexample, for local alarm indication.

Each channel (or piece of equipment) can be configured toinclude up to 4 analogue or serial inputs and 4 contact inputs.

A UPS is installed to enable DataNode to continue logging ifthe mains supply fails.

Control ProgramThe Control Program is used to configure and control aProLog system. The Control Program is a web application;this means that any PC on the network can access thisprogram using a familiar web browser.

The system manager specifies the users who have access tothe system and attaches users to departments.

Usernames, passwords and the required level of accesspermissions are allocated to users so that they can configureand maintain the system, accept alarms and alter settingswithin their designated departments.

Details of alarm acceptances, settings changes and any otherinterventions are recorded in a secure audit trail along withuser’s name and comments.

A channel is configured for each piece of equipment attachedto the system. Sensors are assigned to a channel and upperand lower warning and alarm levels are set. The channelnames, sensor names, alarm messages and optional channeland sensor advisory text are entered. The equipment supplier,part number and serial number are also recorded . . .

Central action pointProlog lite

Central action point Remote site without local action pointRemote site without local action point Major department with local action pointMajor department with local action point Smaller department without local action pointSmaller department without local action point

Email

Smartphone

Prolog lite

Motion detection

Panic button

Door contact

Current input

oltage inputV

Particle count

ferential pressureDif

Carbon dioxide level

Oxygen depletion

Relative humidity

emperatureTTe

InfoPoint

Motion detection

Panic button

Door contact

Current input

V

Particle count

Dif

Carbon dioxide level

Oxygen depletion

Relative humidity

T

Motion detection

Panic button

Door contact

Current input

oltage inputV

Particle count

ferential pressureDif

Carbon dioxide level

Oxygen depletion

Relative humidity

emperatureTTe

Motion detection

Panic button

Door contact

Current input

oltage inputV

Particle count

ferential pressureDif

Carbon dioxide level

Oxygen depletion

Relative humidity

emperatureTTemperature

Email

Alerter + Control Program

required access permissions running

Remote user with passwords and

Alerter + Control Program

required access permissions running

Remote user with passwords and

Internet

Alerter + Control Program

Networked PC running

Ethernet network

Alerter + Control Program

Networked PC running

InfoPoint

Alerter + Control Program

Networked PC running

Alerter + Control Program

Networked PC running

Alerter + Control Program

Networked PC running

LaboratoryMonitoringSystems

Prolog Lite_18-12_Scanlog Leaflet 19/09/2012 17:46 Page 3