Accurately Measuring Mouse Urinary Voiding Frequency and Volume Using The UroVoid System
Learn about new technology that enables noninvasive measurement of mouse urinary voiding frequency and volume from a recognized scientist in the field, Dr. Nathan Tykocki.
InsideScientific is an online educational environment designed for life science researchers. Our goal is to aid in
the sharing and distribution of scientific information regarding innovative technologies, protocols, research tools
and laboratory services.
JOIN FOR FREE AT WWW.INSIDESCIENTIFIC.COM
Gerry Herrera, PhD
Accurately Measuring Mouse Urinary Voiding Frequency and Volume Using The UroVoid System
Catamount R&DMED Associates [email protected]
• MED-CMG Small Animal Cystometry System, developed in early 2000’s
• Allows detailed urodynamic assessment lower urinary tract function in mice
• Very good phenotyping tool
• However, it requires surgical implant of bladder catheter
Measuring Bladder Function in Mice
Urinary bladder instability induced by selective suppression of the murine small conductance calcium-activated potassium (SK3) channel
Need for Noninvasive, Chronic Measurements of Bladder Function in Mice
1. Requires a cage designed for the mouse to live in.
2. Requires access to food and water.
3. Need to prevent food and water from contaminating measurements.
4. Need to separate feces from urine.
5. Need to collect and measure voided urine. Each void time and volume need to be captured.
Mouse Metabolic Cages
www.tecniplast.it www.hatterasinstruments.com www.labproductsinc.com www.colinst.com
Mouse UroVoid
✓ Allows chronic non-invasive measurements of voiding frequency in mice (up to 40 days)
✓ Monitor up to 12 mice simultaneously
click to learn more
Mouse UroVoid
✓ Accurate capturing of time and volume for every void
✓ Full separation of feces/urine
Voiding Micturogram (VMG)
Nathan Tykocki, PhD
Accurately Measuring Mouse Urinary Voiding Frequency and Volume Using The UroVoid System
Research Assistant ProfessorThe University of [email protected]
What We’re Going to Cover Today
1. Bladder function testing
a. What we learn from these experiments
b. Pros and cons of current techniques
2. Designing complex experiments using knockout mice
3. Sample data, protocols, and applications
4. The UroVoid System: Best practices
Bladder Function Testing
Invasive
– Cystometry: Void volume, intermicturition interval (IMI), NVCs; also a clinical tool of bladder function
Non-invasive
– Void Spot Assay: Void volume, void occurrence
– UroVoid System: Void volume, void frequency, IMI, fluid intake over time
Void Spot Assay
• Allow rodents to urinate on filter paper for 2-6 hours
• After drying, urine spots fluoresce when exposed to UV light
• Spot area, location and quantity can be determined using several image analysis software packages (e.g., ImageJ)
• Void spot area: measure of void volume
Yu W, et al. Am J Physiol Renal Physiol 306(11): F1296–F1307, 2014
Void Spot Assay
• Non-invasive
• Inexpensive
• Unimpeded voiding behavior (no catheter)
• Repeatable in the same animal at multiple time points
• Semi-quantitative measure of void volume
• Void frequency difficult to interpret
• False-negatives (urine spot overlap, feces, eating the paper)
• Short duration
Pros Cons
UroVoid System
• Hybrid of spot assay and metabolic cage
• Allow rodents to urinate on a scale for 24-48 hours (maybe longer?)
• Food/water mass can be measured before and after experiment
• Void frequency, volume and urine production rate can be determined with included analysis software
• Void mass: measure of void volume
Experimental Design: Knockout Mice
• Tamoxifen-inducible knockout mice are an indispensable tool to explore basic physiology
• Proper control experiments are key to their power
• This gets tricky with regard to voiding behavior
Experimental Design: Knockout Mice
✓ Time Controls
✓ Vehicle Controls
✓ Genetic Controls
✓ Age Controls
Tim
e
The Biggest Problem?
voiding varies a lot!
Solutions
1. Multiple measures from same animal (or lots and LOTS of animals per group)
2. Maximize data collected from each animal
3. Minimize animal loss post-surgery
4. Maintain tissue viability for further exploration
Limitations with other Methods
Cystometry
• Difficult to do in same animal pre/post tamoxifen
• Risk of infection over time
• Surgical intervention complicates complementary experiments (e.g., isometric force recordings)
• Cost-prohibitive
Void Spot Assay
• Short duration of measurements (~4 h)
• Incomplete measurement of voiding functions
• Safety concerns (tamoxifen in urine)
• Reproducibility can be a problem
In a Perfect World…
✓ Long-term measurements of voiding function
✓ Measures taken before, during and after drug/vehicle administration
✓ reproducible and objective measures of void volume, frequency, and behavior
✓ Non-invasive, yet simple to analyze data
✓ Complementary experiments after voiding behavior is possible
What Do The Data Look Like?
• Unpublished findings using a tamoxifen-inducible knockout mouse
• Tamoxifen delivered by 21-day time release pellet (10 mg/kg)
• Measurements taken 3 time points/ages
– 4 weeks: pre-pellet implantation (implanted at 6 wks)
– 8 weeks: during tamoxifen treatment
– 14 weeks: 5 weeks post-tamoxifen completion
First Test: Example Data
16 weeks of age. Sham (top) or pellet implantation (bottom) surgery 8 weeks prior to recording.
Knockout Mice Voiding Micturogram (VMG)
4 weeks of age. Prior to sham (top) or pellet implantation (bottom) surgery.
14 weeks of age. Sham (top) or tamoxifen treated (bottom).
Knockout Mice Voiding Micturogram (VMG)
Water Intake
• Relatively constant over time
• Small increase in water intake during tamoxifen treatment
• This increase returned to sham levels after treatment
4 wks
(pre
-TM
X)
8 wks
(dur
ing
TMX)
13 w
eeks
(pos
t-TM
X)
0
2
4
6
8
10
12
14
Mass (
g)
Water Intake
KO-Sham
KO-Tamoxifen
Voids Per Day
4 wks
(pre
-TM
X)
8 wks
(dur
ing
TMX)
13 w
eeks
(pos
t-TM
X)
0
2
4
6
8
10
12
14
Void
s p
er
Day
Void Frequency
KO-Sham
KO-Tamoxifen
• Steady decrease with age in sham mice
• Tamoxifen treatment increased void frequency
• This increase never returned to sham levels
• Average volume voided steadily increases in sham mice
• This coincides with the decrease in void frequency
• This increase in volume is much less pronounced in tamoxifen treated mice
4 wks
(pre
-TM
X)
8 wks
(dur
ing
TMX)
13 w
eeks
(pos
t-TM
X)
0.000
0.100
0.200
0.300
0.400
0.500
0.600
Mass (
g)
Average Amount Voided
KO-Sham
KO-Tamoxifen
Void Volume
IntermicturitionInterval
• Steady increase with age in sham mice
• Tamoxifen treatment reduced IMI
• This decrease never returned to sham levels
4 wks
(pre
-TM
X)
8 wks
(dur
ing
TMX)
13 w
eeks
(pos
t-TM
X)
0
50
100
150
200
250
300
Tim
e (
min
ute
s)
Intermicturition Interval
KO-Sham
KO-Tamoxifen
Urine Production Rate
• Defined as amount voided per duration since last void (IMI)
• Measure with the highest variability
• Relative differences between sham and tamoxifen-treated mice is unchanged over time
• Suggests normal kidney function (i.e. the changes in voiding behavior are not due to increased diuresis) 4
wks
(pre
-TM
X)
8 wks
(dur
ing
TMX)
13 w
eeks
(pos
t-TM
X)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Rate
(m
g/m
in)
Urine Production Rate
KO-Sham
KO-Tamoxifen
What Next?
• Cystometry
• Histology/molecular biology
• Isometric force recordings
• Ex vivo afferent nerve recordings
• Any additional techniques to explore the scientific questions at hand
UroVoid System: Best Practices
✓ “Training” does not appear to be necessary
✓ Proper cleaning between experiments is imperative
✓ Cage-mates work best
✓ Quiet, climate-controlled place for entire duration
Given the duration (48+ hours), the little things count:
✓ A quiet humidifier and lighting controls
✓ Turning off the monitor and preventing computer sleep/ screen saver
✓ UPS power supply suggested (if your building is as old as mine)
UroVoid Systems for Rats
• Uses standard metabolic cages
• Cages for rats < 300 grams, and > 300 grams body weight
• Urine collected in special funnel – minimizes evaporation
click to learn more
✓ Very stable voiding patterns
✓ Clear circadian patterns
UroVoid Systems for Rats
Nathan Tykocki, PhDResearch Assistant ProfessorThe University of [email protected]
Gerry Herrera, PhDCatamount R&DMED Associates [email protected]
Thank YouFor additional information on the products and applications presented during this webinar, please visit www.med-associates.com