15
Why there is need for Cable Jointing (Splicing) & Terminations ? COMPAQ INTERNATIONAL (P) LIMITED WWW.COMPAQINTERNATIONAL.COM [email protected]

Why there is need for cable Jointing ?

Embed Size (px)

Citation preview

Page 1: Why there is need for cable Jointing ?

Why there is need for Cable Jointing (Splicing) & Terminations ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 2: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

When you join two or more cables for further distribution, the joints so created are very weak and can be damaged easily. There are many threats for a cable joint such as environmental threats like rain, corrosion, wind and dust. Additionally, chemical contacts and mechanical impacts can also damage the joints. In order to protect these joints and terminals, you must use the cable jointing and termination kits. Compaq offers you a wide range of cable jointing and termination kits, which can be used under various loads starting from 1.1 KV to 72.5KV. The termination and jointing kits are available in both heat shrinkable and cold shrink types; hence they are suitable for both indoor and outdoor installation. They are available for both three core and single core cables.

Cable Joint (Splicing) and Terminations

Page 3: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

What is Joint? The Connection between two cables is called Joint.

What is Termination? The Connection to an equipment is called termination.

Page 4: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

We require cable jointing for following reasons; Cables are heavy and difficult to transport. If there is long feeder line then joint is to be needed. If there is fault in cable then for partial replacement joint is to be needed.

Why there is need for cable jointing ?

Page 5: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

1) Straight through Joints Such types of joints are used for long routes and for repair sections.

Types of Joints

2) Transition Joints Such types are of special type joints used in between two different Cables (Oil filled/XLPE).

Page 6: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

3) T- Joints Such types of joints are used for Branching a feeder.

Types of Joints

4) Branch Y Joints Such types of joints are used for Branching a feeder.

Page 7: Why there is need for cable Jointing ?

Straight Through Joints

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 8: Why there is need for cable Jointing ?

Transition Joints

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 9: Why there is need for cable Jointing ?

Branch Joints

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 10: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

We require cable Termination for following reasons; Cables needs to be connected to an equipment or another cable. End sealing kits are used to cover the cut end of cable against moisture entry. For terminating the cable the termination is needed.

Why there is need for cable Termination?

Page 11: Why there is need for cable Jointing ?

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

1) Indoor Terminations The termination kit is used for indoor terminating of medium voltage cables with belted paper insulation and lead or aluminium sheath. The kit is suitable for three core cables, both armoured and non-armoured.

Types of Terminations

2) Outdoor Terminations The termination kit is used for outdoor terminating of XLPE insulated medium voltage cables with Aluminium/copper wire shield. The kit is suitable for three core or single core cables.

Page 12: Why there is need for cable Jointing ?

Indoor Termination

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 13: Why there is need for cable Jointing ?

Outdoor Termination

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 14: Why there is need for cable Jointing ?

For More information contact Compaq sales team at [email protected]

COMPAQ INTERNATIONAL (P) LIMITED

WWW.COMPAQINTERNATIONAL.COM [email protected]

Page 15: Why there is need for cable Jointing ?

THANKYOU!