1
FLUXUS® ADM______
Non-Intrusive Liquid Flow Measurement
Chemical
Petrochemical
Oil Exploration & Production
Pharmaceutical
Semiconductor
Food and Beverage
Water and Wastewater
Power Generation
District Energy_______________
External Measurement of Internal Flow
2
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Our non-intrusive clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can optimally be configured to meet your individual requirements.
The FLUXUS® flowmeter series comprises a broad variety of transmitters and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous area metering locations.
Our Tradition is Innovation
Ever since its inception, FLEXIM has been among the pioneers in the field of ultrasonic flow measurement. Each FLUXUS® embodies the wealth of ex-pertise and application experience of our engineers.
FLEXIM rises to meet the challenges where others have already failed. Put FLEXIM’s experience and expertise to work for you. Submit your application to us and we will find the ideal solution!
Intelligent Signal Processing
FLUXUS® instruments feature an ex- ceptionally robust dual-μP technology core together with the latest digital signal processing. They produce sta- ble and reliable results even under the most difficult application conditions. The FLUXUS® measurement algo- rithms automatically adapt to the varying application conditions. Its very high measurement rate of up to 1000 measurements per second allows for a real time statistical analysis. All this makes the FLUXUS® unsurpassed in performance and one of the most ca-pable ultrasonic flow meters available on the market today.
FLUXUS® is ...______
3
From 6 mm tubing to 6.5 m penstocksFLEXIM’s non-intrusive ultrasonic technology suits an unmatched range of applications. FLUXUS® offers accurate and reliable measurements from the smallest pipes (e.g. 6 mm tubing in paint finishing systems) up to very large pen-stocks (e.g. flow measure-ments in hydroelectric plants).
For nearly every liquid and pipe materialMeasurement is possible on just about every liquid medium and pipe material, regardless of the conductivity. Steel, iron or plastic pipes; sludge, sand, acids or tar: FLUXUS® is up to the task!
Up to 400 °C and beyond
Standard transducers may be used for media temperatures up to 130 °C, the temperature range of the high temp. versions extends this up to 200 °C. The patented WaveInjector® system further extends the measurement ran-ge of FLEXIM’s standard transducers from cryogenic temperatures as low as -190 °C up to 400 °C and beyond.
... even in hazardous area locationsTransducers and transmitters are avail- able in ATEX, IECEx and FM certified versions.
Flexible.______
4
The advantages of the non-intrusive measurement are obvious: since the ultrasonic transducers are simply attached to the outside of the pipe, the measuring equipment is not subject to wear and tear by the media and does not cause any pressure losses.
Measurements at maximum operating pressures can be carried out easily with no additional costs. No pipe work is required when setting up the measuring point and, as a result, the operation is not interrupted.
100% plant availability p Simple attachment of the VARIOFIX
transducer system on the outside of the pipe
p Installation is possible during normal ongoing operation without process downtime
100% resistant to media p No contact with media, therefore
no chemical attack
p No need to use expensive special materials
100% wear-free p No wear and tear by abrasive media
p Long-term stable, maintenance-free operation due to permanent coupling pads
100% leak-proof p No additional risk of leakage
by the measuring equipment
100% pressure-resistant p No pressure limit
p Effortless measurement even at maximum operating pressures
p No extra charge for high pressure ranges
p Zero point stability and measure- ment readings are not affected by static pressure changes
100% secure p No blockage of small bores or
impulse piping
p Unaffected by pulsations, vibrations, speed peaks, swirling or cross flows
100% robust p Resistant to pressure surges, solids
or bubbles in the medium
Non-intrusive.______
5
100% economical p No pressure loss, thus low
operating costs
p Cost-effective installation
p Installation without welding or other mechanical work on the pipe
p No extra charge for large pipe diameters
100% progressive p Precise, hysteresis-free,
bi-directional flow measurement with large dynamic range (turndown)
p Long-term stable, drift-free measurement results
p High measuring rate
p Quick response time
p Measurement of even minute flows
p High sensitivity to low flows
6
“Plug & Play” calibrated transducers
Each pair of transducers undergoes a rigorous calibration at the factory and is shipped with traceable calibration documentation. All calibration data (includ- ing the transducer identification and parameters) is stored in a transducer- resident non-volatile memory. It is automatically transferred to the transmitter upon connection. Consequently, programming errors are eliminated and there is never a need for zero adjustment or calibration.
Guaranteed to be user friendlyNo elaborate instructions are required to use FLUXUS®‘s intuitively structured menus. Pipe and material parameters are easily found in the internal liquid media and pipe materials database. Measurement is activated with just a few key strokes. Our explosionproof instruments can be operated without having to open the housing and without requiring any additional programming devices.
A “Straight-Shot” from the pipe to the PC
FluxData connects FLUXUS® to any PC. This software package with a graphical user interface takes care of the data exch-ange between the transmitter and the computer. With FluxData, you can readily transfer your measurement data from the flowmeter to a PC, analyze and visualize the measuring results and manage the data files directly or easily export them to an external data management program for analysis.
User-Friendly.______
7
* for measurement acc. to transit time difference principle, under reference conditions and at v > 0.15 m/s** reference uncertainty < 0.2 %
General Technical Data
Measuring principle: Transit time difference correlation principle
Quantities of measurement: Volume flow, mass flow, flow velocity, thermal energy flow (when temperature inputs are installed)
Flow velocity: 0.01 to 25 m/s
Resolution: 0.25 mm/s
Repeatability: 0.15% of reading ± 0.01 m/s
Accuracy*:- with standard calibration: - with extended calibration (option):- with field calibration**:
± 1.6 % of reading ± 0.01 m/s± 1.2 % of reading ± 0.01 m/s± 0.5 % of reading ± 0.01 m/s
Gaseous and solid content: < 10 %
Measuring principle
The Transit Time Difference Correlation Principle makes use of the fact that the time-of-flight of an ultrasonic signal is affected by the flow velocity of the carrier medium. Like a swimmer working his way across a flowing river, an ul-trasonic signal travels slower upstream than downstream.
Our instruments work according to this transit-time prin-ciple: an ultrasonic pulse is sent downstream through the medium, another pulse is sent upstream. By measuring the transit time difference, the average flow velocity can be determined. The volume flow can then be calculated out of the flow velocity and the pipe’s dimensional parameters.
The acoustic measuring method works without inertia and is independent of the flow direction. As a result, FLUXUS® measures the flow bidirectionally with excellent measurement rangeability.
8
The Transducer System
“Fit for the Purpose“ Construction
All FLEXIM clamp-on transducers are watertight and suitable for use in harsh industrial environments. The robust stainless steel construction and the rugged integrated cables guarantee reliable measurement results over long periods of extensive use. Almost all transducer types are available in explosion-protected and IP68 submersible versions.
Robust transducer mounting fixtures
Be it for quick and easy mounting of a short-term measurement solution or for a permanent installation, for large pipes or for small tubes: FLEXIM offers transducer mounting fixtures for every application.
The VARIOFIX mounting fixture pro- vides for a strong hold. Even in the event of strong temperature fluctuations, a continuous, stable contact pressure between the transducers and the pipe is ensured, allowing for the optimal irradiation of measuring signals into the medium.
The VARIOFIX transducer mounting fix-ture exists in two versions: VARIOFIX L and VARIOFIX C.
Both are constructed of stainless steel, being completely corrosion resistant and very durable. The transducer dis-tance can be set easily and precisely. Maintenance requirements are reduced considerably due to the permanent pipe wall contact with coupling pads.
VARIOFIX L is the standard transducer mounting fixture and VARIOFIX C provides for optimum protection even in the harshest conditions: beneath the stainless steel cover, the measu-ring point is permanently protected against external influences, wind and weather as well as mechanical damage.
Industry Hardened.______
9
General Technical Data of the Transducers
Operating temperature, standard transducers: -40 °C to +130 °C
Operating temperature, high temperature transducers:
-30 °C to +200 °C
Operating temperature with WaveInjector®: from -190 °C up to 400 °C and beyond
Protection degree: IP65, IP67 or IP68 depending on type (EN 60529)
Material: Stainless steel or PEEK with stainless steel protective cap (stainless steel SS316 optional)
Hazardous area classification: FM Class I, Div. 1 / 2 and ATEX (IECEx) Zone 1 & 2 types available (FMUS and FMC and GOST)
10
Unmatched in performance, this flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.
The wide pipe diameter range of each transducer type is one of its greatest assets: two pairs of transducers are sufficient to cover the most common pipe diame-ter ranges.
In addition, its optional thermal energy measure- ment capability makes it possible to carry out a com-plete analysis of thermal energy usage in any fa-cility. The collected data can be used to perform a complete energy balance assessment or to assist dur- ing process monitoring and optimization tasks.
Refrigeration and air conditioning systems
p Measurement of inlet and outlet flow for service work and maintenance
p Pump preventative maintenance and checks
p Optimization of energy efficiency p Detection of fouling processes in
heat exchangers
Power supply p Short-term replacement of insert
energy meters in case of failures
Facility management p Optimization of heating and
air conditioning systems in large building complexes
p Pump control
Applications
Portable, quick and reliable.______
FLUXUS® F601 and F608
SUPPLY
SUPPLY
RETURN
RETURN
Flow measurement
Temperature measurement Temperature measurement
Supply Return
General p Service and maintenance p Replacement of defective devices p Support of commissioning process
and installation p Performance and efficiency
measurement - Evaluation and assessments - Capacity measurement of pumps - Monitoring of regulating valves
p Energy efficiency audits
Mechanical engineering and plant engineering
p Leak detection on hydraulic systems
p Measurement of cooling lubricant p Monitoring of heating and cooling
circuits
11
Food and beverage industry p CIP and SIP optimization
p Consumption optimization
Chemical industry p Portable flow controls at start-up
and/or inspection of facilities p Helpful tool for facility optimization p Flow measurement of heat
transfer media
Water supply and wastewater services
p Leakage control p Treatment dosage control
p Flow control in water supply networks
Pharmaceutical and semiconductor industry
p Non-invasive measurement of ultra pure fluids, even in PVC, PFA and glass pipes
F601 / F608: The Portable All-Round Meters
Operating temperature: -10 °C to +60 °C
Flow channels: 2
Protection degree: Electronic unit: IP65 acc. to EN 60529 Transport case: IP67 acc. to EN 60529
Hazardous Area Classification (F608):
ATEX (IECEx) Zone 2, FM Class I, Div. 2 (Transducers: ATEX (IECEx) Zone 1 and 2, FM Class I, Div. 2)
Battery: Li-Ion, 7.2 V/4.5 Ah, >14 hours operating time
Inputs and outputs: Standard:
Outputs: 2 x current, 2 x binary
Energy: Inputs: 2 x Pt 100/1000; Outputs: 2 x current, 2 x binary
Double Energy (only F601):
Inputs: 4 x Pt 100/1000; Outputs: 2 x current, 2 x binary
Multifunctional (only F601):
Inputs: 2 x Pt 100/1000, 2 x current; Outputs: 4 x current, 2 x binary
Certified for the usage in hazar-dous areas, the highly rugged FLUXUS® F608 avoids the need for a „Hot work permit“ and is thus the system of choice for temporary measurement tasks within the:
p Chemical Industry p Petrochemical Industry p Refineries p Oil & Gas Exploration p as well as in Power plants
12
The FLUXUS® ADM 7X07 and F705 are designed for permanent installation. With one or two flow channels and versatile electrical inputs and outputs, they can optimally be configured for your measuring application. A variety of process parameters, including thermal energy (BTU) and mass flow rates, can be measured and handled. Further, with its stainless steel (316L / 1.4404) housing, IP66 protection degree and ATEX (IECEx) Zone 2 / FM Class I, Div. 2 certification, the F705 is the ideal measuring solution for corrosive and harsh industrial environments including Offshore.
Applications
Chemical industry p Measurement of corrosive or toxic media,
for example in the chlorine chemistry p Measurement of non-conductive media p Measurement of highly viscous media p Measurement of media containing
fibers or solid particles p Measurement of long-chained polymers p Measurement of highly concentrated
sulfuric acid p Measurement of heat transfer
media such as water/glycol (250 °C) and thermal oils
p Measurement on PVC or FRP pipes and tubes
Petrochemical industry p Measurement of basic materials
as well as intermediate and final products
p Measurement at high temperatures, for example tar, bitumen, quench liquids
Power plants p Measurements of cooling water,
boiler feed water, condensate and heat circuits
Oil and Gas p Measurement of all hydrocarbon
liquids p Measurement on high pressure
systems p Measurement of bitumen p Measurement of injection media
and additives
Pharmaceutical and semiconductor industry
p Non-invasive measurement of ultra pure fluids, even in PVC, PFA and glass pipes
Permanently installed, freely configurable.______
FLUXUS® ADM 7X07 and F705
13
Power plants p Measurements of cooling water,
boiler feed water, condensate and heat circuits
Oil and Gas p Measurement of all hydrocarbon
liquids p Measurement on high pressure
systems p Measurement of bitumen p Measurement of injection media
and additives
Pharmaceutical and semiconductor industry
p Non-invasive measurement of ultra pure fluids, even in PVC, PFA and glass pipes
Food and beverage industry p Hygienic contact-free measurement
of liquids p Thermal energy measurement in
the energy supply of central boilers and sanitizing machines
Water and waste water industry p Flow measurement on large diameter
pipes (influent, effluent, sludges) p Consumption and distribution
measurements p Measurement in underground or
underwater pipes p Chemical flows
(small pipe and low flows)
Mechanical engineering and plant engineering
p Leak detection on hydraulic systems p Measurement of cooling lubricant p Monitoring of heating and cooling
circuits
ADM 7X07 / F705: The Multi-Functional Meters
Operating temperature: -20 °C (-40 °C for F705) to +60 °C
Flow channels: 1 or 2
Protection degree: ADM 7407 / F705: IP65 / IP66 (EN 60529) ADM 7907: IP20 (EN 60529)
Hazardous Area Classification:
ADM 7407 / F705: ATEX (IECEx) Zone 2, FM Class I, Div. 2
Outputs: A variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
Inputs: Maximum 4. Available are: Temperature (Pt 100/1000 4-wire), current, voltage
Interfaces: HART, Modbus (RS485), BACnet
14
The FLUXUS® ADM 8027 is ATEX certified for stationary use in ex- plosion hazardous areas. Its connection and electronics compartment are hermetically sealed. It can be operated without having to open the enclosure and without any additional devices.
The all-stainless-steel and seawater-resistant FLUXUS® ADM 8127 is also ATEX-certified and thus ideally suited for offshore applications.
Applications Petrochemical industry
p Measurement of basic materials as well as intermediate and final products
p Measurement of crude oil during sampling for quality analysis
p Measurement at high temperatures, e.g. - Sump measurement - Overflash measurement
p Measurement of heavy gasoil (HGO)/heavy vacuum gasoil (HVGO)
p Measurement at cracker feeders p Monitoring the flow of heat
transfer oil
Chemical industry p Flow measurement in explosion
hazardous areas p Measurement of inorganic
and organic media
Experts for Hazardous Areas.______
FLUXUS® ADM 8X27
15
Applications Petrochemical industry
p Measurement of basic materials as well as intermediate and final products
p Measurement of crude oil during sampling for quality analysis
p Measurement at high temperatures, e.g. - Sump measurement - Overflash measurement
p Measurement of heavy gasoil (HGO)/heavy vacuum gasoil (HVGO)
p Measurement at cracker feeders p Monitoring the flow of heat
transfer oil
Chemical industry p Flow measurement in explosion
hazardous areas p Measurement of inorganic
and organic media
Oil extraction p Flow measurement of injection
media, for example methanol p Flow measurement of injected
water p Measurement of the feeding
process into sand separators for process management
p Flow measurement of condensate p Measurement on high pressure
systems
Natural gas extraction and processing
p Measurement of injection media (monoethylamine, triethylene glycol, etc...)
p Measurement of reservoir water
ADM 8027 / ADM 8127: The Explosion-Proof Experts
Operating temperature:
ADM 8027: -20 °C to +60 °C; ADM 8127: -20 °C to +50 °C
Flow channels: 1 or 2
Protection degree:
Electronic unit: IP65 acc. to EN 60529 Transport case: IP67 acc. to EN 60529
Hazardous Area Classification:
ATEX zone 1 and 2; ATEX mining certification optional
Outputs: 240V (AC) / 24V (DC) current supply version: 2 current outputs and 4 binary outputs (OC) or 2 current outputs, 2 binary outputs (OC) and 2 binary outputs (relay) or 1 frequency output and 1 binary output (OC)24V (DC) current supply version (intrinsically safe): 1 current supply and 1 binary output (OC)
Interfaces: HART, ModBus (RS485)
FLEXIM______
In partnership with you
FLEXIM is an active leader in many areas of process instrumentation. As a worldwide pioneer in the non- intrusive flow measurement of liquids and gases, FLEXIM has been leading the way in ultrasonic clamp-on flow metering for more than 20 years. In addition to non-intrusive flow mea- surement, FLEXIM specialises in inno-vative online process analysers using ultrasonic technology and refractometry.
Sustainable and progressive
measurement technology
Year after year, the Berlin based company continues its substantial investment in research and develop-ment in order to maintain and further improve its position as an industry lead- er. In keeping with its core principles, FLEXIM takes customer feedback very seriously. Every generation of FLEXIM products is directly driven by customer and industry needs.
The FLEXIM commitment to customer service
FLEXIM considers itself not only a manufacturer of measuring instru-ments, but also a provider of technical and consulting services. These ser-vices include instrument rentals, on- site measurements, laboratory anal-ysis, project handling, training, com-missioning and consulting services.
The company’s focus and dedication is
directed towards providing the highest quality equipment with the best support
and service possible.
FLEXIM GmbHBerlin, Germany
Phone: +49 30 93 66 76 60 Fax: +49 30 93 66 76 80 [email protected]
FLEXIM Instruments Benelux B.V.Berkel en Rodenrijs, Netherlands Phone: +31 10 24 92 333 Fax: +31 10 24 92 339 [email protected]
FLEXIM France SARLStrasbourg, France Phone: +33 388 27 78 02 Fax: +33 388 27 78 45 [email protected]
FLEXIM Instruments UK Ltd.Northwich, Cheshire United Kingdom Phone: +44 1606 781 420 Fax: +44 1606 784 544 [email protected]
FLEXIM InstrumentsAsia Pte Ltd. Singapore Phone: +65 67 94 53 25 Fax: +65 68 62 28 36 [email protected]
Shanghai, ChinaPhone: +86 21 64 95 75 20 [email protected] www.flexim.com
BU
LIQ
UID
V8-2
EN 0
1/20
14
Sub
ject
to c
hang
e w
ithou
t not
ifica
tion