A Deeper Understandingof Corrosion Control
Utilizing no-fuss, practical implementation of new technologies for improved long-term corrosion
prevention
The #1 factor determining the success or failure of protective coatings
(including galavanization)
Scope of Metal Surface Preparation
Corrosion Control FAILURE:Weak, Shallow Surface Cleaning
“Conventional surface preparation systems set up
mechanisms for coating failure because they
fail to account for & address the
roots of corrosion.”
Visually Clean, Blasted Surfaces ContainMicroscopic Contaminants
Visual Standards Fail to RecognizeMicroscopic Contaminants
Contaminants Clearly Visualized Under Microscopic Examination of “Clean” Blasted Surface
Contaminants Draw Moisture From the Atmosphere
Microscopic Contaminants Bondwith Atmospheric Moisture
Corrosion Process (Flash Rusting) Begins
Visual Standards Fail To Recognize Microscopic Oxidation
Coating Covers Microscopic Contaminants and Oxidation (Rust)
Coating Conceals but Does Not Remove Contaminants and Oxidation (Rust)
Contaminants and Oxidation (Rust) Become “Ticking Time Bomb” of Corrosion Reactions
Moisture Moves Through Coating via Osmosis
Hydrostatic Pressure Builds Beneath Coating
Corrosion Reactions Occur & Rust Develops Beneath Coating
Expansion of Corrosion Reactions Causes Coating Delamination
Corrosion Blisters “Bloom” Compromised Coating & Metal Fail
Corrosion Control SUCCESS:Deep Surface Decontamination
“CleanWirx surface decontamination pio-neers
an entirely new category of surface prepa-ration that
gets to the roots of corrosion to eliminate impurities
that interfere with coating adhesion & per-formance.”
Microscopic Contaminants Recognized and Anticipated After Abrasive Blast Cleaning
Metal is Treated with CleanWirx Decontamination Gel
CleanWirx Gel Allowed to Dwell on Metal 30 Minutes
CleanWirx Gel Dissolves & EliminatesMicroscopic Contaminants
Metal is Pressure Washed with CleanWirx Rinse
CleanWirx Rinse Washes Away Gel
Decontaminated Metal Dries Ready to Coat
Microscopic Analysis Confirms Absence ofMicrocontaminants, Film & Residue on CleanWirx- Treated Metal
Coating is Applied to (CleanWirx-Treated)Decontaminated Metal
No Corrosion Mechanisms Remain Under CoatingSo Coating Adhesion & Performance Are Unimpeded
Assets Treated with CleanWirx Last Longer Due to More Uniform Coating Adhesion & Longevity
SIMPLE, EFFICIENT REMOVALOF MICRO-CONTAMINANTS
& INTERFERENCE MATERIALS
1 2 3
1 apply CleanWirx gel to blasted metal
spray, brush, dip or roll on
2 wait 30 minutes (recommended dwell time)
micro-contaminants removed & suspended in gel
3 pressure wash with CleanWirx rinse
decontaminated surface ready to applyyour choice of paint or protective coating
Non-Film FormingCoating NeutralHolds the BlastBiodegradable
Non-Hazardous
• NO inhibitors• NO dehumidifica-
tion• NO acid wash• NO re-blasting
• LEANER• GREENER• FASTER• DEEPER
Better Process
Better Solu-tion
• Lengthens coating maintenance intervals up to 5x
• Single-pass continuous process, even across large surfaces
• Removes impurities thoroughly for no-hassle compliance
• Significant process time and cost savings
Better Re-sults