Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Embed Size (px)

DESCRIPTION

It's silde about ionization tech.in mass spectrometry.

Citation preview

Page 1: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Presented by:-Ashutosh Panke (M.Pharmacy,Pune.)

Page 2: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Ionization TechniquesIonization Techniques Electron Impact (EI)Electron Impact (EI) Chemical Ionization (CI)Chemical Ionization (CI) Negative Ion Chemical Ionization (NICI)Negative Ion Chemical Ionization (NICI) Spray Methods:Spray Methods: Atmospheric Pressure Chemical Ionization (APCI)Atmospheric Pressure Chemical Ionization (APCI) Fast Atom Bombardment (FAB)Fast Atom Bombardment (FAB) Field Ionization (FI)Field Ionization (FI) Good for Gas Phase Samples (e.g. for GC Detector)Good for Gas Phase Samples (e.g. for GC Detector) Continuous Ion Source, High degree of Continuous Ion Source, High degree of

FragmentationFragmentation

Page 3: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Ionization TechniquesIonization Techniques

Electro spray Ionization (ESI)Electro spray Ionization (ESI) Matrix Assisted Laser Desorption Ionization Matrix Assisted Laser Desorption Ionization

(MALDI)(MALDI) Other Methods:Other Methods: Secondary Ion Mass Spectrometry (SIMS)Secondary Ion Mass Spectrometry (SIMS) Inductively Coupled Plasma (ICP)Inductively Coupled Plasma (ICP)

Page 4: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Ionization SourcesIonization Sources The scope and utility of a mass spectrometric method is dictated The scope and utility of a mass spectrometric method is dictated

by the ionization process.by the ionization process. The appearance of mass spectra for a given molecular species is The appearance of mass spectra for a given molecular species is

highly dependent upon method used for ion formation.highly dependent upon method used for ion formation. Ion sources are classified into two major categoriesIon sources are classified into two major categories Gas Phase: Gas Phase: - Applicable to thermally stable compounds with mol.Wt. less - Applicable to thermally stable compounds with mol.Wt. less

than 10 than 1033D or Boiling point less than 500D or Boiling point less than 50000C.C.

- Sample is 1- Sample is 1stst vaporized and then ionised. vaporized and then ionised. Desorption:Desorption: - Applicable to analytes with mol. Wt. as large as 10- Applicable to analytes with mol. Wt. as large as 1055D . D .

- Sample in solid state or liquid state is directly converted into - Sample in solid state or liquid state is directly converted into gaseous ions.gaseous ions.

Page 5: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Fast Atom bombardment (FAB)Fast Atom bombardment (FAB)

Polar molecules, such as peptides with mol. wt. up to 10000 Polar molecules, such as peptides with mol. wt. up to 10000 daltons can be analyzed by a ‘soft’ ionization technique called daltons can be analyzed by a ‘soft’ ionization technique called FAB.FAB.

The bombarding beam consists of xenon or argon atoms of high The bombarding beam consists of xenon or argon atoms of high translational energy. This beam is produced by 1translational energy. This beam is produced by 1stst ionizing xenon ionizing xenon atoms with electrons to give xenon radical cations.atoms with electrons to give xenon radical cations.

These radical cations are accelerated to 5-15 kev to give radical These radical cations are accelerated to 5-15 kev to give radical cations of high translational energy which are then passed cations of high translational energy which are then passed through xenon.through xenon.

During this passage, the charged high energy xenon obtains During this passage, the charged high energy xenon obtains electron from the xenon atoms and the Xe.+ ions removed by an electron from the xenon atoms and the Xe.+ ions removed by an electric field.electric field.

Page 6: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Fast atom bombardment (Fast atom bombardment ( FAB)FAB) Softer than EI and CI. Ions are produced by bombardment with Softer than EI and CI. Ions are produced by bombardment with

heavy atoms. Good for more polar compounds.heavy atoms. Good for more polar compounds.

Xe + e XeXe + e Xe++ acceleration (5-15 KeV) acceleration (5-15 KeV)

Xe+ + Xe Xe + XeXe+ + Xe Xe + Xe++

fast slow fast slow ++ 8 KeV 8 KeV fast slowfast slow

Page 7: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

AdvantagesAdvantages

Parent IonParent IonHigh Mass Compounds High Mass Compounds

(10,000 amu)(10,000 amu)Thermally Labile Thermally Labile Compounds (R.T.)Compounds (R.T.)

DisadvantagesDisadvantages

No Fragment LibraryNo Fragment Library

Solubility in Matrix Solubility in Matrix (MNBA, Glycerol)(MNBA, Glycerol)

Quantitation DifficultQuantitation Difficult

Needs Highly Skilled Needs Highly Skilled OperatorOperator

Relatively Low SensitivityRelatively Low Sensitivity

Properties of FABProperties of FAB

Page 8: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Matrix Assisted Laser Desorption Matrix Assisted Laser Desorption Ionization (MALDI)Ionization (MALDI)

MALDI is achieved in two steps. In the first step, the compound to be analyzed is dissolved in a solvent containing in solution small organic molecules, called the matrix. The second step occurs under vacuum conditions inside the source of the mass spectrometer.

sample is co-crystallized with a matrix and then irradiated with laser.

Page 9: Mass spectrometry(Ionization Techniques) by Ashutosh Panke
Page 10: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

MALDI ( Matrix assisted laser desorption/ MALDI ( Matrix assisted laser desorption/ ionization)ionization)

In this technique an In this technique an aqueous/alcoholic solution of aqueous/alcoholic solution of sample was mixed with a large sample was mixed with a large excess of a radiation absorbing excess of a radiation absorbing matrix material.matrix material.

The resulting solution was The resulting solution was evaporated on the surface of a evaporated on the surface of a metallic probe that was used for metallic probe that was used for introduction of the sample into introduction of the sample into the mass spectrometer.the mass spectrometer.

The solid mixture is exposed to a The solid mixture is exposed to a pulsed laser beam, which pulsed laser beam, which resulted in sublimation of the resulted in sublimation of the analyte as ions.analyte as ions.

Page 11: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

1111

SELDI-TOF MS

Page 12: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

1212

SELDI – Surface-Enhanced Laser Desorptionand Ionization

For SELDI :-

• Proteins are cocrystallized with UV-absorbing compounds. • Vaporized by a pulsed-UV laser .• Ionized proteins are accelerated in an electric field • Mass to charge ratios of the different protein ion species are measured.

Also called SELDI-TOF-MS• TOF – Time of flight

Page 13: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

1313

Differences between SELDI and MALDI

SELDI • Wider mass range than MALDI• Biomarker discovery

MALDI• High accuracy in the lower peptide range • Protein identification

Page 14: Mass spectrometry(Ionization Techniques) by Ashutosh Panke
Page 15: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Electrospray Ionization Electrospray Ionization

Most important technique for analyzing biomolecules such as polypeptides, Most important technique for analyzing biomolecules such as polypeptides, proteins and oligonucleotides having mol. Wt. of 10000 D or more.proteins and oligonucleotides having mol. Wt. of 10000 D or more.

Electrospray ionization takes place under atmospheric pressure and Electrospray ionization takes place under atmospheric pressure and temperature.temperature.

A solution of the sample is pumped through a stainless steel capillary needle A solution of the sample is pumped through a stainless steel capillary needle at a rate of few microliter/min.at a rate of few microliter/min.

The needle is maintained at several kilo-volts with respect to a cylindrical The needle is maintained at several kilo-volts with respect to a cylindrical electrode that surrounds the needle.electrode that surrounds the needle.

The resulting charged spray of fine droplets then passes through a desolvating The resulting charged spray of fine droplets then passes through a desolvating capillary, where evaporation of the solvent and attachment of a charge to the capillary, where evaporation of the solvent and attachment of a charge to the analyte molecules takes place.analyte molecules takes place.

As the droplet becomes smaller as a consequence of evaporation of the As the droplet becomes smaller as a consequence of evaporation of the solvent, their charge density becomes greater and desorption of ions into the solvent, their charge density becomes greater and desorption of ions into the ambient gas occurs.ambient gas occurs.

Page 16: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

AdvantagesAdvantagesElectrospray Ionization can

be easily interfaced to LC.Absolute signals from Electrospray are more easily reproduced, therefore, better quantitation.Mass Accuracy is considered better.Multiple charging is more common then MALDI.

DisadvantagesDisadvantages

No FragmentationNeed Polar Sample

Need Solubility in Polar Solvent (MeOH, ACN, H2O, Acetone are best)

Sensitive to SaltsSuppression

Properties of ESIProperties of ESI

Page 17: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

MASS ANALYZERS:MASS ANALYZERS:

Function: Function: To separate the ions produced in To separate the ions produced in the ion source acc. to their mass/charge ratio.the ion source acc. to their mass/charge ratio.

Ideally mass analyzer should be capable of Ideally mass analyzer should be capable of distinguishing small mass differences.distinguishing small mass differences.

It should also allow passage of a sufficient It should also allow passage of a sufficient number of ions to yield radially measurable number of ions to yield radially measurable ion current.ion current.

Page 18: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Classification of Mass Analyzer:Classification of Mass Analyzer:

1)1) SECTOR ANALYZERSSECTOR ANALYZERS

a)a) Magnetic field only - Single Focusing Mass AnalyzerMagnetic field only - Single Focusing Mass Analyzer

b)b) Magnetic and electrostatic field - Double FocusingMass Magnetic and electrostatic field - Double FocusingMass AnalyzerAnalyzer

2)2) TIME OF FLIGHT ANALYZER ( TOF ) TIME OF FLIGHT ANALYZER ( TOF )

3)3) QUADRAPOLE ANALYZERSQUADRAPOLE ANALYZERS

a)a) Quadrapole filterQuadrapole filter

b)b) Ion trap analyzerIon trap analyzer

4) FT – MS ( Ion cyclotion Resonance – Mass Spectrometer ) 4) FT – MS ( Ion cyclotion Resonance – Mass Spectrometer ) ( ICR-MS)( ICR-MS)

5) MS – MS ( Tandem Mass Spectroscopy )5) MS – MS ( Tandem Mass Spectroscopy )

Page 19: Mass spectrometry(Ionization Techniques) by Ashutosh Panke
Page 20: Mass spectrometry(Ionization Techniques) by Ashutosh Panke
Page 21: Mass spectrometry(Ionization Techniques) by Ashutosh Panke
Page 22: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

Time of Flight Mass AnalyzerTime of Flight Mass Analyzer::

• “Pulse” of ions are accelerated into analyzer– Very small range of kinetic energies (ideally all have same KE)– Since masses vary, velocity must also vary• Ions enter a field-free region, the drift tube, where theyare separated on the basis of their velocities– Lighter ions (smaller m/z) arrive at the detector first, heavier ions(larger m/z) arrive later

Page 23: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

REFERANCEREFERANCE

Organic Spectroscopy by Organic Spectroscopy by Pavia,Lampman,Kriz page no:402-415.Pavia,Lampman,Kriz page no:402-415.

Instrumental method of chemical analysis by Instrumental method of chemical analysis by G.R. Chatwal & S.K. Anand. G.R. Chatwal & S.K. Anand. Page no: 2.275-2.282.Page no: 2.275-2.282.

Website:-Website:- www.freepdf.com www.bioinformatics.ualr.edu www.sildeshare.netwww.sildeshare.net

Page 24: Mass spectrometry(Ionization Techniques) by Ashutosh Panke

THANK YOU…THANK YOU…