Transcript
Page 1: XDD DFFFF2 5HY˛˝ ; $ 1ipcmty.com/wp-content/uploads/2015/07/94311-3A.pdf · 2015. 7. 30. · XDD DFFFF2 5HY˛˝ ; $ Detonation Flame Arresters 2 94311/94312/94313/94314 Class 300

5911 Butterfield Road Hillside, IL 60162 • tel: (708) 236-6000 • fax: (708) [email protected] • www.ljtechnologies.com • ISO 9001 Registered Rev: 9431X-3A

1

94311/94312/94313/94314Detonation Flame Arresters

Features • Withstands instantaneouspressure

attheFlamefrontinexcessof500psig

• Tubebankdesignensuresconsistentfunctioning

• Carbon steel or 316 S.S. housingconstruction,316S.S.tubebank

• Optionalfittingsforpressuretapsortemperatureprobes

• Designed&testedinaccordancewithappendixA, 33U.S.CodeofFederalRegulationspart154

• Standarddrainplug

• Pressure and temperature tapsoptional

TheShand&JursDetonationFlameArrestersprovideprotectionagainstflamepropagationthroughpipingruns and vapor recovery systems,while allowingmaximumflowefficiencies. Thisdesignquenchesaflamefrontapproachingfromeitherdirection,evenifithastransitionedtoadetonation.TheArresterscontainadetonationwhileretainingtheintegrityofboththearrestingelementandthehousing.Thisisensuredbythedesignofthepassagesinthetubebankandthedetonationresistantconstruction.

Standardconstructionof thehousing isavailable inCarbon Steelor 316 Stainless Steel. The tubebankis Stainless Steel throughout. Special constructionmaterialstowithstandthecorrosiveactionsofsomevapors andatmospheric conditionsareavailableuponrequest.

Becauseof the severe serviceconditions that theDetonationFlameArresterencounters,allconstructionweldingisperformedinaccordancewithASMEBoilerandPressureVesselCodeSectionVllland IX.Class150lb.hydrostaticallytestedat425psig.Class300lb.hydrostaticallytestedat750psig.

Thesemodelsareavailableinarangeofsizesfrom2”through24”.Additionalsizesavailableuponrequest.StandardconnectionsareANSI150lb.or300lb.Classraisedfaceflanges.

9431X Detonation Flame Arresters

Model Number Service / Approval* Size

94311 NECGroupD/FactoryMutual 2”-12”

94312 NECGroupDMarine/FactoryMutual,U.S.CoastGuard 2”-12”

94313 NECGroupC&D/FactoryMutual 2”-6”

94314 NECGroupC&DMarine/FactoryMutual 2”-6”

*STEEL,316,DUPLEXStainlessSteel

Page 2: XDD DFFFF2 5HY˛˝ ; $ 1ipcmty.com/wp-content/uploads/2015/07/94311-3A.pdf · 2015. 7. 30. · XDD DFFFF2 5HY˛˝ ; $ Detonation Flame Arresters 2 94311/94312/94313/94314 Class 300

5911 Butterfield Road Hillside, IL 60162 • tel: (708) 236-6000 • fax: (708) [email protected] • www.ljtechnologies.com • ISO 9001 Registered Rev: 9431X-3A

Detonation Flame Arresters

2

94311/94312/94313/94314

Class 300 lb.

Class 150 lb.

Dimensions

Size 2” 3” 4” 6” 8” 10” 12” 18”“A” 305/16 351/16 379/16 451/16 605/16 749/16 761/16 6913/16“B” 61/2 81/4 10 121/2 15 171/2 201/2 28“C” 10 121/2 15 201/2 251/2 301/2 36 471/2

Size 2” 3” 4” 6” 8” 10” 12” 14” 16” 18”“A” 291/16 339/16 361/16 431/16 581/16 7115/16 739/16 595/16 595/16 6113/16“B” 6 71/2 9 11 131/2 16 19 21 231/2 25“C” 9 11 131/2 19 231/2 271/2 32 383/4 383/4 433/4

Alldesignssubjecttochange.Certifieddimensionsandspecificationsavailableuponrequest.

Specifications

Materials of Construction

Sizes:2”,3”,4”,6”,8”,10”,12”,14”,16”,18”,20”,22”,24”DINSizesAvailable

CarbonSteel,316StainlessSteel,Carpenter20,Hastelloy-C,orDuplexStainlessSteel.(OtherMaterialAvailable)

150/300 lb.

Flange Rating:ANSI150lb.or300lb.


Recommended