WIRING DIAGRAMSplit System Air Conditioner (Outdoor Section)Notes: 1) Disconnect all power before servicing. 2) For supply connections use copper conductors only. 3) Furnace/Air Handler w/factory equipped 24 V control circuit transformers, should be modified/rewired to ONLY use 24V transformer from outdoor section. See installation instructions for typical modifications. 4) For replacement wires use conductors suitable for 105° C. 5) For ampacities and overcurrent protection, see unit rating plate.
C S
R
T2
T3
T1
T1 T2 T3
L1 L2 L3
BLACK
BLACK
RED
BLACK
BLACK
YELLOW
COMPRESSOR
LOW PRESSURESWITCH
HIGH PRESSURESWITCH
ORANGE
PURPLE
PURPLE
BLACK
WHITE
GREENBLACK
RED
YELLOW
BLACK
OUTDOOR FANMOTOR
CONTACTOR
ANTI-SHORT-CYCLE TIMER
CS
R
CCH
T2T3
T1
COMPRESSOR
CC
ASCT
ASCT
L1 L2 L3
LOW PRESSURESWITCH
HIGH PRESSURESWITCH
CC CC CC
OUTDOOR FANMOTOR
R Y C
ISOLATED T-STAT CONTACT
24V FOR INDOORCONTROL CIRCUIT
CYR
BLACK
Field WiringHigh VoltageLow Voltage
Factory WiringHigh VoltageLow Voltage
3-PHASE SUPPLYVOLTAGE