WIRING DIAGRAM Split System Air Conditioner (Outdoor Section) Notes: 1) Disconnect all power before servicing. 2) For supply connections use copper conductors only. 3) Furnace/Air Handler w/factory equipped 24 V control circuit transformers, should be modified/rewired to ONLY use 24V transformer from outdoor section. See installation instructions for typical modifications. 4) For replacement wires use conductors suitable for 105° C. 5) For ampacities and overcurrent protection, see unit rating plate. C S R T2 T3 T1 T1 T2 T3 L1 L2 L3 BLACK BLACK RED BLACK BLACK YELLOW COMPRESSOR LOW PRESSURE SWITCH HIGH PRESSURE SWITCH ORANGE PURPLE PURPLE BLACK WHITE GREEN BLACK RED YELLOW BLACK OUTDOOR FAN MOTOR CONTACTOR ANTI-SHORT- CYCLE TIMER C S R CCH T2 T3 T1 COMPRESSOR CC ASCT ASCT L1 L2 L3 LOW PRESSURE SWITCH HIGH PRESSURE SWITCH CC CC CC OUTDOOR FAN MOTOR R Y C ISOLATED T-STAT CONTACT 24V FOR INDOOR CONTROL CIRCUIT C Y R BLACK Field Wiring High Voltage Low Voltage Factory Wiring High Voltage Low Voltage 3-PHASE SUPPLY VOLTAGE 1) Couper le courant avant de faire letretien. 2) Employez uniquement des conducteurs en cuivre. Three Phase 7039770 ¢703977V¤

Wiring Diagram-Split System Air Conditioner

  • Upload
    semirza

  • View
    165

  • Download
    4

Embed Size (px)

Citation preview

Page 1: Wiring Diagram-Split System Air Conditioner

WIRING DIAGRAMSplit System Air Conditioner (Outdoor Section)Notes: 1) Disconnect all power before servicing. 2) For supply connections use copper conductors only. 3) Furnace/Air Handler w/factory equipped 24 V control circuit transformers, should be modified/rewired to ONLY use 24V transformer from outdoor section. See installation instructions for typical modifications. 4) For replacement wires use conductors suitable for 105° C. 5) For ampacities and overcurrent protection, see unit rating plate.

C S

R

T2

T3

T1

T1 T2 T3

L1 L2 L3

BLACK

BLACK

RED

BLACK

BLACK

YELLOW

COMPRESSOR

LOW PRESSURESWITCH

HIGH PRESSURESWITCH

ORANGE

PURPLE

PURPLE

BLACK

WHITE

GREENBLACK

RED

YELLOW

BLACK

OUTDOOR FANMOTOR

CONTACTOR

ANTI-SHORT-CYCLE TIMER

CS

R

CCH

T2T3

T1

COMPRESSOR

CC

ASCT

ASCT

L1 L2 L3

LOW PRESSURESWITCH

HIGH PRESSURESWITCH

CC CC CC

OUTDOOR FANMOTOR

R Y C

ISOLATED T-STAT CONTACT

24V FOR INDOORCONTROL CIRCUIT

CYR

BLACK

Field WiringHigh VoltageLow Voltage

Factory WiringHigh VoltageLow Voltage

3-PHASE SUPPLYVOLTAGE

1) Couper le courant avant de faire letretien. 2) Employez uniquement des conducteurs en cuivre.

Three Phase

7039770¢703977V¤