Transcript
Page 1: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Wind Induced Vibration of Cable Stay Bridges Workshop

April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Page 2: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

New Developments in Cable Stay Vibration Suppression

Andrew Micklus, P.E.COO FREYSSINET LLC

Page 3: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Table of Contents

1. Stay Cable System Details2. Sources of Vibration3. Review of Available Vibration Suppression Devices4. Project Examples5. Conclusions

Page 4: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Bundle of individually protected strands• Individual anchorage with wedges• In an outer stay pipe

Freyssinet Parallel Strand System (PSS)

Page 5: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Parallel Strand Stay Cable System

• Hot dip galvanization– 190 to 350 g/m² of zinc– applied before final drawing of wires

(no loss of ultimate strength)• Wax filling around and within strand

– adhesion properties anti-corrosion layer– lubrication against fretting fatigue– prevents expense of zinc (redundancy)

• Semi-bonded HDPE coating (patented)– shape designed for semi-bond (only 12 g/m wax)– UV stabilized, shock resistant– Extruded on the strand

Page 6: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Multi function compact anchorage

Individual Wedge anchor

Fixed or adjustable Nut

Watertightness

Bending filtration

Stay Anchorage – General Layout

Page 7: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Each strand is guided individually by a trumpet with controlled curvature

– bending < 250 MPa in transition zone – bending < 50 MPa in anchorage

• Allows SLS design to 0.50 fGUTS instead of 0.45

1. Freyssinet Stay Cable SystemStay Anchorage – Bending Filtration

Page 8: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

0

24

68

12 31 55 75 109

0.95 GUTS

0.45 GUTS

2 millions cycles

Force

Time

PTI testPTI test

• Nearly 100 multi-strand fatigue and ultimate tests according to PTI and CIP recommendations

200 MPa

Testing – Mechanical Performance

Page 9: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Testing - Waterproofing

Page 10: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

anchor blockon sliding plate

steel tube

Stay anchorage

2. Heater [20 - 70°C]

dyed water

1. Jack for axial loading[0.20 - 0.50 GUTS ]

h ≈

3m

3. Transversaljack for bending

[+/- 25 mrad]

Testing - CIP Waterproofing Test

Total test duration = 6 weeks

Page 11: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Extension of outer anticorrosion barrier– Active stuffing box – Anchorage casing fully treated against corrosion

• Micro-crystaline wax injection– Reversible injection– Very high thermal

stability (90°C )

• Passed rigorous testing– PTI Leak Test Reversible injection– CIP/SETRA Waterproofing Tests

Stay Anchorage - Corrosion Protection

Page 12: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Testing - CIP Waterproofing Test

Page 13: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Vibration Sources

• Aerodynamic phenomena on stay cables are complex • Numerous sources of vibrations, some of the most

frequently encountered:

1. Rain & wind induced instability2. Motion induced / parametric

excitation3. Vortex shedding / buffeting4. Others (Wake galloping,

ice accumulation galloping, etc)

Page 14: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Stay Cables are Sensitive to Vibrations Due to Very Low Internal Friction (Intrinsic Damping)– Good fatigue behavior (low fretting)

reduced intrinsic damping– Intrinsic damping can be increased with additional dampers

(internal or external)

Stay Cable Vibrations

Page 15: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Rain/Wind Induced Vibrations

• In Case of Moderate Rain and Wind:– rivulets of water flow along the stay pipe– upper rivulet oscillates and creates stay instability

• Large Amplitude Vibration (over 1 meter)

wind wind U = 7 to U = 7 to 15m/s15m/s

Page 16: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Amplitude

Wind velocity

No fillet

Fillet

7m/s 15m/s

Rain/Wind Induced Vibrations

Page 17: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Deck and pylon response to gusty winds– Deck displacement periodic displacement – Pylon displacement of stay anchorages

Motion Induced / Parametric Excitation

Instability whenfstruct = k . fstay

k = ½, 1, 2

Page 18: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Transversal Excitation of Stay Anchorage

• Resonance: When Frequencies are Equal : fstruct = fstay

• Stay Amplitude ~ Anchorage Amplitude Multiplied by 2/δ– 5 mm amplitude deck oscillations can generate +/- 500 mm

stay oscillations• Solution: Add damping

Motion Induced / Parametric Excitation

Page 19: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Longitudinal Excitationof Stay Anchorage

• Instability When Frequencies Double:

• fstruct = 2 . fstay

• Solution: – Place cross tie cables to shift stay frequencies

Motion Induced / Parametric Excitation

Page 20: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Obstacle in Laminar Air Flow Von Karman Vortices• Vortex Shedding Oscillating Vertical Force Fv

• No instability, but solution = increase damping

Number Strouhal22.0U

Df)tf2(cosF)t(Fv

==⋅

π=

Vortex Shedding

Fv

Page 21: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Stay Cable VibrationsBuffeting

• Gusty Wind from Large Obstacles on Upstream Flow• Dynamic Response of Stay Cables

– amplitude depends on total damping δtot = δint + δaero

• Limit Amplitude Under Moderate Wind (15 m/s)– increase intrinsic damping with additional dampers

Page 22: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Vortices from Upstream Cable– twin cables– longitudinal winds

• Solutions : – increase damping– place cross ties

laminar windif L< x.D3 < x < 5L

Stay Cable VibrationsWake Galloping

Page 23: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Ice / snow

Wind

Ice Accumulation

Stay Cable VibrationsWake Galloping

Page 24: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Preventive Actions

• Profiled stay pipe• Compact stay pipe• Add damping devices

– Internal dampers– External dampers– Tuned mass cable dampers

• Cross ties (aiguilles)• Reduce bridge vibration

– Deck profiling with spoilers,– Deck or pylon tuned mass damper

Page 25: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Profiled Stay Pipe

• External layer– color and UV protection

• Internal layer– mechanical resistance

• Two helical fillets– rain & wind induced instability

• Thickness / diameter ratio– adjusted for ungrouted solutions : ex 200mm x 6.2mm

Page 26: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Profiled Stay Pipe

• Freyssinet profiled helical rib– Initially for Normandy bridge twin shells

• Shape optimized for drag reduction– Drag factor CD = 0.60,

Page 27: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Amplitude

Wind velocity

No fillet

Fillet

7m/s 15m/s

Profiled Stay Pipe

• Freyssinet double helical rib– extruded during duct fabrication– disorganize water rivulets– prevents efficiently rain & wind

vibration

• Tested in CSTB and DMI laboratories

Page 28: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Profiled Stay Pipe

• Drag is a Concern on Long Stays (over 400 meters)

• Freyssinet Profiled Pipe : Lowest Drag Coefficient• Reduce Diameter D: further minimize drag

– special installation method– optimize components– compact stay pipe

x2

air DCU21drag ρ=

Page 29: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Freyssinet Compact Stay System• Drag force on a stay cable

• Static drag is cumulated over a large area on stays• Severe load on bridge if

– very long span (> 800 m)– single shaft pylon

• 22% Pipe OD Reduction

Dair CDUdrag ...21 2ρ=

Curve force deck/stay

stays

deck

Transverse force

Span200 600400 800 1,000

Page 30: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

2Freyssinet compact stay pipe

• Reduced outer diameter D– 15.7 x 1860 MPa strand– special

installationmethods

– Reduce D 22% Ø21

5

91

Ø225

109

Ø250

Ø240

121 130

Ø15

0

42

Ø195

75

Ø200

85

Ø17

0

57

Page 31: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Internal Dampers

• Since 1994 Freyssinet has developed a range of internal dampers

• Each system is replaceable and easy to maintain• All systems have been fatigue tested

Page 32: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Internal Elastomeric Damper (IED)

Elastomeric diabolo made of high damping rubber

Page 33: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Internal Hydraulic Damper (IHD)

Page 34: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Movable piston

Moving steel chamber

Viscous oil

Internal Hydraulic Damper (IHD)

Page 35: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Internal Radial Damper (IRD)

• Low aesthetical impact• Easy maintenance• Replaceable• Low dependence on T°

Page 36: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Internal Radial Damper (IRD)

• Easy and Fast installation• Higher Stroke

• Increase of δ=5%• Efficiency with A

Page 37: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Internal Radial Damper (IRD)•Three radial piston dampers•Steel collar clamped to cable •Steel guide tube connected to the structure

Page 38: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Theoretical Limit to Damper Efficiency

• Damping depends on– distance d damper - anchorage– cable length L

• Theoretical limit

– E.g. 300 m cable and d = 3 m then δ < 3%

• Critical for gussets orvery long stays (L > 300m)

Ld

opt πδ <

Page 39: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Viscous vs. Friction DampersTesting at the French National CEBTP

Testing for Sutong Bridge China on 92m (300 ft) Cables

Log. decrement

Vibration amplitude

Viscous damper: λ and k constant

Friction damper low efficiency for small amplitudes

Threshold (dry friction)

Page 40: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Fixed External Dampers (FED)

• Generally defined due to geometry:– distance d is too small– cable length too long– gussets not stiff enough

• Fixed external damper (FED):multiple pistons on fixed frame

Page 41: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Pendular External Dampers (PED)

• Two piston dampers on articulated lever– Normandy– Ting Kau

Téta

H

1328

.904

mm

This section is square atthis point to avoid pylonrotation

Tube Dia 219 thick 5orTube Dia 219 thick 10

37.730°

Angle téta

ANGLE Alpha

Page 42: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Cross Ties

• Provide "fix" point along stay cable– shift stay modal frequency– E.g. only even modes with one cross tie in the middle

• Useful for very long stays – In case of parametric instability– Over 400 meters

• Special cross tie system for Normandy Bridge– 3 years of R&D

Page 43: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Cross Ties

• Use of a specifically designed cable– continuous cable– symmetrical around stay cable– high damping rope

• Anchorage– high fatigue resistance– bending filtration

Page 44: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Tuned Mass Dampers

• Log Decrement up to 10%• Spring-Mass system : same mass in both tubes• M and k adapted to the damping requirements

Page 45: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Damper Tests ResultsCooper River Bridge

Stay Number Damper Type N° of measurement Design Criteria Average Value

202N SIHD 4 3% 6.11%207N SIHD 5 3% 3.65%210N DIHD 5 3% 3.79%216S EHD 7 6% 13.62%

Page 46: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Alternate Techniques• Windshield/Spoiler• Stucture Mass Tuned Dampers

Page 47: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IEDDee Crossing Bridge (France - 1977)

Vasco Da Gama Bridge Over the Tagus River (Portugal - 1998)

Charles River Bridge (USA - 2002)

Millau Viaduct (France - 2004)

Bridge Over the Vistula in Plock (Poland - 2004)

Ice Rink of Moscow (Russia - 2004)

Page 48: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IED

Millau Viaduct

Page 49: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IED

Charles River Bridge

Page 50: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IHDVasco Da Gama Bridge Over the Tagus River (Portugal - 1998)

Ting Kau (Hong Kong - 1998)

Oresund Bridge (Sweden - 2000)

My Thuan (Vietnam - 2000)

Seohae Grand Bridge (South Korea – 2002)

Bridge Over Panama Canal (Panama - 2004)

Millau Viaduct (France - 2004)

Bridge Over the Vistula in Plock (Poland - 2004)

New Cooper River Bridge (USA - 2005)

Shenzhen Western Corridor Bridge (Hong Kong - 2005)

Bai Chay Bridge (Vietnam - 2006)

Bridge Over Rio Orinoco (Venezuela - 2006)

Page 51: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IHD

Orinoco Bridge

Panama Bridge

Page 52: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IHD

Cooper River Bridge

Page 53: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IHD• No aesthetical impact• Stroke 40mm (1.6”)

Cooper River Bridge

Page 54: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IRDOresund Bridge (Sweden - 2000)

Shenzhen Western Corridor Bridge (Hong Kong - 2005)

Bai Chay Bridge (Vietnam - 2006)

Southern Outer Bangkok Ring Road (Thailand - 2007)

Page 55: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IRD

Bai Chay Bridge

Page 56: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of IRD

Oresund Bridge

Page 57: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of FEDBrotonne Bridge (France - 1977)

Iroise Bridge Over the Elorn River (France - 1994)

New Cooper River Bridge (USA - 2005)

Page 58: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of FED

Elorn Bridge

Page 59: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

• Higher log dec δ=6%• Higher Stroke > 50mm (2”)

Applications of FED

Cooper River Bridge

Page 60: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of FED

Page 61: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of PEDNormandy Bridge (France - 1995)

Ting Kau (Hong Kong - 1998)

Rion Antirion Bridge (Greece - 2004)

Page 62: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of PED

Normandy bridge

Page 63: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of Cross TiesNormandy Bridge (France - 1995)

Second Severn Bridge (UK - 1996)

Oresund Bridge (Sweden - 2000)

Charles River Bridge (USA - 2002)

Rion Antirion Bridge (Greece - 2004) : Provisional

New Cooper River Bridge (USA - 2005) : Provisional

Page 64: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of Cross Ties

Normandy Bridge

Normandy Bridge

Page 65: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Applications of Cross Ties

Normandy bridge

Cooper River Bridge

Page 66: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Conclusions

• Incorporate damper design at the structure design stage, preferred over a post-construction “fix”

• In depth dynamic analysis of the structure• Selection of anchoring scheme influences damper

selection and efficiency• Adapt solutions on a case-by-case (cable-by-cable)

basis for vibration mitigation• Consider combination of dampers and alternative

means

Page 67: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Conclusions• Considerations:

– Stay length– Environmental considerations– Seismic considerations– Anchorage details (maximize “d” between damper &

anchor)– Stay pipe with double helical rib: always

• Locate dampers at deck level for ease of inspection & maintenance combination of dampers and alternative means

Page 68: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Conclusions

• For Preliminary Damper Design Guidelines:

• Provision for cross ties: if L >150 m and risk of parametric excitation

IRD or FED150 < L < 300 m

IRD or PEDL > 300 m

IHD80 < L < 150 m

IEDL < 80 m

Recommended damperStay length

Page 69: Wind Induced Vibration of Cable Stay Bridges Workshop ... · PDF fileWind Induced Vibration of Cable Stay Bridges Workshop April 25 –27, 2006 St Louis, MO FREYSSINET LLC

Thank You!


Recommended