Agilent Technologies InterLatin
UNIX to Windows Upgrade
Agenda
• 3070 History and Controller EOS
• Benefits of Windows upgrade
• 3070 SW releases
• Conversion Tools
3070 History
HP 3060
HP 3065
HP 3070
HP 3070 Series II
Agilent 3070
Series 3 UNIX
WN-based Agilent 3070
Medalist i5000
1970 1980 1990 1999 2001 2002 Feb 2005 Feb 2007 2009 2013
Medalist i3070
Series 5 Medalist i3070
Series 5 In-line
HP announced the Manufacturing Discontinue for PA-RISC UNIX Workstation
Medalist i3070
Controller End Of Support
Page 5
Process of Upgrading- Dual Boot Benefits
• Lowest risk approach
• No conversion needed for custom scripts developed on UNIX
• Space out the conversion workload. Not affecting production
• Option to new run PC programs and have UNIX as backup
• Flexibility (UNIX and PC capability on 1 system)
Page 6
i3070 is a valuable asset!
1) Easy to use Operator and Debug Interface
2) AutoDebug & AutoOptimizer tools
3) Test throughput enhancements
4) Award winning Vectorless Test solutions
5) Interactive Pin Locator
Page 7
i3070 can do all these! Manufacturing Problem Features Benefits
Lack of skilled engineers / operators and high employee turnover rate
Graphical Operator and Debug Interface
1) Simple to Use 2) Reduced engineer learning time 3) Less reliance on Operator's proficiency in English
Auto-Debug Increased analog debug productivity through intuitive GUI and Autodebug Tools
Test-time indication Maintenance of test time through monitoring of test time during debug
High production output
Improved test generation algorithm improves throughput
- Resistor and Capacitor tests are generated with test-time optimisation considerations - Shorts test with improved algo to reduce phantom shorts
Improved Analog test throughput (Auto-Optimizer)
-Increased return on asset on test budget -Ensure stability by using statistics (user specified CPK)
Need to be able to re-use existing test fixtures and programs
Transportability to and from 3070 / i5000
Test investment protection
Need to be able to easily and quickly deploy worldwide
Transportability, Repeatability, and Stability
Our Trusted, Robust, Simple-to-use tester is easy to deploy
Lower test investment Lower list price Better return on investment
Page 8
i3070 - Key new features – increased productivity
• Graphical User Interface
• IPG Enhancements – Interactive Pin Locator Tool
– AutoDebug Tool
– AutoOptimizer Tool
– Compatibility
– VTEP 2.0
Page 9
Graphical User Interface
• Windows-based familiarity • Simple point and click interface
• Different Logins for test code security • Operator Login
• Engineer Login
• Administrator Login
Page 10
Graphical User Interface
Operator Login
Page 11
Engineer Login
Graphical User Interface
Page 12
• New board tests generated with the new IPG will be faster!
• Capacitor test improvements – Improved IPG algorithm on frequency selection
• Improved algorithm of Capacitor tests using fr1024
• Select fr1024 instead of fr128 => reduce on “ed” measurements
• Possible savings of about 48% over total analog test time or about 19% of total board test time
• Resistor test improvements – Adding of guarding to cancel capacitive impedance
– Recalculating wait time for capacitive charging
– Possible savings of about 9% over total analog test time or about 3% improvement over total board test time.
IPG Enhancements - Improved IPG!
Page 13
Auto-Debug Tool
• Just by the click of a button
• Unpowered Analog Tests will be debugged based on rules that you set.
Page 14
Auto-Debug Tool
Page 15
Auto-Optimizer Interface • Just by a click of a button
• The Optimizer can save from 10% to 50% of test time per test!
The Optimizer will only work with Control XTP cards.
Page 16
Interactive Pin Locator
Gone are the days when you have to find the probe/pin based on the BBRRCC!
Page 17
3070 Software Release - Recent History
• 5.30: Unix and Windows 2000
– Vectorless Test Extended Performance: VTEP – (Windows only)
– New SW License implementation
– X-Tree Testing Syntax added to VCL
– Worst Probe Report
– Customer Requested Enhancements & Bug Fixes
– Last Unix Release
Last UNIX Release
• 5.31 & 5.32: Windows 2000
– Vectorless Test Extended Performance: VTEP – (Windows only)
– Customer Requested Enhancements & Bug Fixes
Page 18
3070 Software Release - Recent History
(cont) • 5.40/5.41: Windows XP
– Windows XP – iVTEP – iYET – dynamic retest of failed components – ScanWorks 3.7 including support for 1149.6 – Customer Requested Enhancements & Bug Fixes
• 7.00: Windows XP for 3070 and i5000
– i3070 feature set
• 5.42: Windows 2000 & XP
– 5.40 & 5.41 features for Windows 2000
Page 19
3070 Software Release - Recent History
(cont) • 7.10/7.20: Windows XP SP2
– Cover-ExTend technology
– Boundary Scan 1149.6
– Customer Requested Enhancements & Bug Fixes
• 8.20/8.30: Windows XP 32 bits and Windows 7 32 & 64 bits
– Agilent LED tests
– High voltage Zener tests.
– New BootP Turbo SW.
• 8.00: Windows 2000 & XP
– New Series 5 – ASRU-N System Speed up option feature
– External DLL Control
– Improved Power capabilities (Safety)
Page 20
Conversion Tools
• Prerequisites – Have a board directory with the testplan, test and all the files
compiled on SW revision b4.00pa or later.
– Be able to run IPG Test Consultant withour errors!!!
– Know the locations of board directories on both operating systems.
– Have enogh disk space. This is verified by the Conversion tool
– Know the remote logins, controller names and/or IP addresses and password of both systems.
Running the Conversion Tool • The Conversion Tool main screen has the same file
menu in both HP-UX and MS Windows. The Conversion Tool consists of five functions:
• Package: Merges and compresses all of the boards/<BoardName> directories text files into a single <BoardName>.cvt file.
• Transfer: Used to transfer files using FTP (file transfer protocol) to another ftp server-enabled controller.
• Extract: Extracts (uncompresses) a packaged <BoardName>.cvt file in a platform-dependent manner.
• View Log: Used to view resulting log files. • Abort: Aborts the Package or Extract process.
Running the Conversion Tool
Agilent 3070 Conversion Tool
• Review the Relevant Differences Between
HP-UX and MS Windows Operating Systems
• Verify that duplicate file names, except for
case (capitalization) in the HP-UX system,
are not causing problems.
• Search for /dev/* files in the
<BoardName>.cvt file that have meaning in
HP-UX, but are not applicable to MS
Windows.
Troubleshooting Problems
Q&A