7/28/2019 Understanding Emergency Equipment in DENTISTRY
1/15
EMERGENCY EQUIPMENTS ALL SINGLE USE
LATEX FREE.Air way:
Procedure for insertion of oropharyngeal airway
7/28/2019 Understanding Emergency Equipment in DENTISTRY
2/15
Don gloves (if available).
Clear the patient's airway, apply suction if necessary.
Estimate the correct size of the airway by placing it against the patient's face and
measuring it from the angle of the jaw to the incisors (Fig 1). The correct size is one that
equates to the vertical distance between the incisors and the angle of the jaw (Nolan et
al, 2005). If possible, lubricate the airway before insertion (practically, in the emergency situation,
this is rarely done).
Open the patient's mouth, clear the airway, using suction if necessary, and insert the
airway in the inverted position (Fig 2) (the curved part of the airway will help press the
tongue down and prevent it from being pushed posteriorly).
As it passes over the soft palate, rotate the airway through 180 (Fig 3).
Following insertion, confirm that the airway is in the correct position - the patient's
airway should be improved and the flattened reinforced section should be positioned in
between the patient's teeth or gums if there are no teeth (Resuscitation Council (UK),
2000).
Closely monitor the patency and position of the airway; it can become blocked by thetongue or epiglottis and can become wedged into the vallecula (Marsh et al, 1991).
Vomit, secretions and blood can also compromise its patency.
BRONCO SPASM:
SPACER DEVICE
Breathing:
7/28/2019 Understanding Emergency Equipment in DENTISTRY
3/15
It features a 500 Litre D-size
O2 cylinder, non-detachable 2-flow regulator (5 and 15 ipm) c/w tubing connector, adult therapymask and tubing and a single-use self-inflating resus bag with adult mask.
7/28/2019 Understanding Emergency Equipment in DENTISTRY
4/15
Non-rebreathable mask, partially rebreathable mask, and venturi mask are different types of face
masks used in medical treatment for administering oxygen to patients.
1. Non-rebreathable mask is named so because it is designed to prevent mixing of
atmospheric air or the air exhaled by the patient with the oxygen. This type of mask allows
up to 90% concentration of oxygen to be delivered to the patient. However, too much
administration of oxygen can also cause medical problems, hence it is used only when
specifically prescribed and with proper medical attention.
2. Partially rebreathable mask block the intake of the atmospheric air only partially. Use of
such masks result in patient breathing about 40% to 60% concentration of oxygen.
Reservoir masks come in two types: a partial rebreather mask and a non-rebreather mask. Similar in
appearance, both masks have a reservoir bag that fills with oxygen, and the bag must be kept
inflated. These are considered low flow devices, but can deliver higher oxygen concentrations than a
simple face mask. However, a partial rebreather mask has no one-way valves; a non-rebreather
mask has a small one-way valve on the outside of the mask and another inside the mask at the top
of the bag where it connects to the mask. These valves allow expired CO2 to leave the mask.
Conserving devices are designed to decrease the
3. Venturi mask is is a mask that uses a mechanical vent that increases the rate of flow of
oxygen into the mask. This type of mask increases the supply of total oxygen for
breathing, but the concentration of oxygen supplied is about just 24% to 28%
7/28/2019 Understanding Emergency Equipment in DENTISTRY
5/15
7/28/2019 Understanding Emergency Equipment in DENTISTRY
6/15
Well-fitting adult and child masks attached to self-inflating bag
7/28/2019 Understanding Emergency Equipment in DENTISTRY
7/15
7/28/2019 Understanding Emergency Equipment in DENTISTRY
8/15
Fig. 3. Specific functions of the bag-valve-mask system that require testing, using non-disposable (upper) and disposable
(lower) Laerdal devices as examples. Visual and functional testing of the mask (A), patient valve (B), oxygen intake system (C),
emergency air-intake system (D), pressure relief valve (E) and reservoir bag (F) are mandatory to ensure proper operation.
Self-inflating bag.
7/28/2019 Understanding Emergency Equipment in DENTISTRY
9/15
Circulation:Capillary refill time, central pulse, peripheral pulse.
Single use syringes
7/28/2019 Understanding Emergency Equipment in DENTISTRY
10/15
EMERGENCY DRUGS:
Adrenaline Injection BP 1/1000 (1mg/1ml) Each 1ml of solution contains adrenalineacid tartrate BP equivalent to 1mg of adrenaline. Clear, colourless, sterile, aqueous
7/28/2019 Understanding Emergency Equipment in DENTISTRY
11/15
solution, intended for parenteral administration to human beings. Adrenaline is adirect-acting sympathomimetic agent.
Adrenaline may be used to provide rapid relief of severe hypersensitivity reaction todrugs and other allergens, and in the emergency treatment of anaphylactic shock.
Severe hypersensitivity reactions, anaphylactic shock>>IM Injection:
Adults: The usual dose is 500 micrograms (0.5ml of adrenaline 1/1000). If necessary, this dose may
be repeated several times at 5-minute intervals according to blood pressure, pulse and respiratory
function.
Half doses of adrenaline may be safer for patients who are taking amitriptyline, imipramine or a
beta blocker.
Children: The following doses of adrenaline 1/1,000 are recommended:
Age Dose
Over 12 years 500 micrograms (0.5ml)
250 micrograms (0.25ml) if child is small or prepubertal
6 - 12 years 250 micrograms (0.25ml)
6 months - 6 years 120 micrograms (0.12ml)
Under 6 months 50 micrograms (0.05ml)
If necessary, these doses may be repeated several times at 5-minute intervals
according to:blood pressure, pulse and respiratory function.
Adrenaline Injection contains sodium metabisulphite, which can cause allergic-typereactions, including anaphylaxis and life-threatening or less severe asthmaticepisodes, in certain susceptible individuals.
The presence of sodium metabisulphite in parenteral Adrenaline and the possibilityof allergic-type reactions should not deter use of the drug when indicated for thetreatment of serious allergic reactions or for other emergency situations.
The patients' ability to drive and use machines may be affected by the anaphylactic reaction,
as well as by possible adverse reactions to adrenaline.
7/28/2019 Understanding Emergency Equipment in DENTISTRY
12/15
7/28/2019 Understanding Emergency Equipment in DENTISTRY
13/15
EPIPEN
ORAL GLUCOSE 2O GM
1MG IN1ML STERILE WATER
7/28/2019 Understanding Emergency Equipment in DENTISTRY
14/15
100MICROGRAM/PUFF 2 PUFF NORMAL ADULT DOSE DOUBLE DURING EMERGENCY
IF NO IMPROVEMENT/SEVER SYMPTOMS GV4-6 DOSE W VOLUMETRIC DEVICE EVERY
10MIN.
STEPS:1.CORRECTGRIP,
HOLDTHEINHALERINMYFAVOURITEHAND,USETHEINDEXFINGER
ATTHETOPOFMOUTHPIECEANDTHUMBONTHEBASEOFMOUTH
PIECE.
2.DO ONE GOOD STRONGORALEXHALATION TRY NOT TO BREATH
OUT THROUGH YOUR NOSE. DO IT THROUGH YOUR MOUTH.
7/28/2019 Understanding Emergency Equipment in DENTISTRY
15/15
3.ORAL INHALATION PUT THE MOUTH PIECE SECURELY IN
MOUTH AND SPRAY THE MEDICINE INSIDE
INHALE WHILE THE MEDICINE BEING SPRAYED, MAKE SURE
MEDICINE GOES INTO LUNGS THROUGH AIR PASSAGES AND NOT
THRU TO YOUR STOMACH.
4 CORRECT DOSAGES:
5.MEDICAL ASSISTANCE INHALER ARE FOR IMMEDIATE
RELIEF, IT IS STILL IMPORTANT TO CONSULT GP, PROPER
MEDICAL ADVICE