Transcript
Page 1: PROLINK POWER BACKUP SOLUTION

Your Inspirations.Our Innovations.

POWER BACKUP SOLUTIONUNINTERRUPTIBLE POWER SUPPLY (UPS)

Page 2: PROLINK POWER BACKUP SOLUTION

1

TABLE OF CONTENTS

TABLE OF CONTENTSAbout Us – Company Profile

Online UPS

Professional I Series (1P/1P) – Tower P.F 0.8

Professional II Series (1P/1P) – Tower P.F 0.8

Professional II Series (1P/1P) – Rack P.F 0.8

Professional II Series (3P/1P) – Tower P.F 0.8

Professional II+ Series (1P/1P) – Tower P.F 0.9

Professional II+ Series (1P/1P) – Rack P.F 0.9

Master II Series (1P/1P) – Tower P.F 0.9

Master II Series (1P/1P) – Tower P.F 1.0

Master II Series (1P/1P) – Rack/Tower P.F 0.9

Master II Series (1P/1P) – Rack/Tower P.F 1.0

Master II Series (3P/3P) – Tower P.F 0.9

Master II+ Series (3P/1P) – Tower P.F 0.9

Master II+ Series (3P/1P) – Rack P.F 0.9

Master II+ Series (3P/3P) – Tower P.F 0.9

Master II+ Series (3P/3P) – Rack P.F 0.9

Power I Series (3P/3P 400VDC) – Tower P.F 0.9

Giant Series (1P/1P) – Tower P.F 0.8

Giant Series (3P/1P) – Tower P.F 0.8

Giant I Series (3P/1P) – Tower P.F 0.8

Giant I Series (3P/3P) – Tower P.F 0.8

Giant Industrial Series (3P/1P 220VDC) – Tower P.F 0.8

Giant Industrial Series (3P/1P 384VDC) – Tower P.F 0.8

Giant Industrial Series (3P/3P 384VDC) – Tower P.F 0.8

Giant Industrial Series (3P/3P 480VDC) – Tower P.F 0.9

Sorra Series Rack/Tower P.F 1.0

Extend Series (3P/3P 400V) – Tower P.F 1.0

Titan Series (3P/3P 400V) – Tower P.F 1.0

PRO-R Series P.F 0.8

2

4

4

7

10

13

16

19

22

25

29

32

36

38

41

44

50

53

58

61

64

67

69

71

73

75

77

79

81

84

86

86

89

92

95

98

98

100

107

107

109

109

110

111

111

115

116

116

Line Interactive UPS

PRO SFC Series

PRO SFT Series

PRO-L Series

Outdoor Line Interactive Series

Inverter

Simulated Sinewave Inverter Series

Pure Sinewave Inverter Series

Auto Voltage Regulator

PVR Series

DC UPS

PDC12V

PBU Series

Software & Accessories

PROLiNK Online UPS Accessories

Remote Monitoring & Management

Appendix

Battery Cabinet

Page 3: PROLINK POWER BACKUP SOLUTION

2

Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name “PROLiNK®” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in the area of Back-up UPS products.

Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively.

The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured that they are getting true value - superior quality products at affordable prices.

PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency.

Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.

IDEAS, INNOVATION AND INFORMATION

PROLiNK® aims to be the key driving force behind

technological changes and improvements in both developing

and developed countries. With its strong focus on technology,

our team sets high standards for itself in the areas of

innovation, change and improvement so as to provide the

next generation of users with products that are suitable for

their technology advanced environments.

The small “i” in PROLiNK represents ideas, innovation and

information – three key pillars of growth that drive us

towards achieving excellence in our field of expertise and

challenges us to think beyond our usual boundaries.

OUR VISION

ACCENTUATE THE BEST FOR THE E-GENERATION

PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace.

OUR MISSION

ABOUT US

ABOUT US - COMPANY PROFILE

Page 4: PROLINK POWER BACKUP SOLUTION

3

Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name “PROLiNK®” since 1991. With more than two decades of professional experience in the information communications sector, PROLiNK is now renowned as a specialist in its field, especially in the area of Back-up UPS products.

Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide the right solutions to meet the needs of both home and business users within each geographical location both efficiently and effectively.

The company’s quest for continuous improvement and quality assurance to its customers has earned us the ISO9001 quality certification since 1999. With its consistently strong commitment to quality, customers can be assured that they are getting true value - superior quality products at affordable prices.

PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our products are crafted to enhance performance whether you are at work or play – our products work harder, while you work smarter to achieve your desired results with less effort and better efficiency.

Providing value to our consumers – whether home or business users, remains a firm commitment of PROLiNK. With its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions for their technological needs, while business users are assured of reliable and secure solutions for their network infrastructure.

IDEAS, INNOVATION AND INFORMATION

PROLiNK® aims to be the key driving force behind

technological changes and improvements in both developing

and developed countries. With its strong focus on technology,

our team sets high standards for itself in the areas of

innovation, change and improvement so as to provide the

next generation of users with products that are suitable for

their technology advanced environments.

The small “i” in PROLiNK represents ideas, innovation and

information – three key pillars of growth that drive us

towards achieving excellence in our field of expertise and

challenges us to think beyond our usual boundaries.

OUR VISION

ACCENTUATE THE BEST FOR THE E-GENERATION

PROLiNK® aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming more and more commonplace.

OUR MISSION

ABOUT US

ABOUT US - COMPANY PROFILE

CORE VALUESSECURED INFORMATION MANAGEMENT

With more than two decades of professional experience in providing backup power solutions to our customers, we are able to support our customers with superior technological know-how and expertise, as well as advice on market trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage confidential information discreetly.

INNOVATIVE DESIGN

Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With the team’s solid experience in the UPS market, customers can be certain that our designs are innovative yet functional, and suitable for each dynamic market that we have a presence in.

SUPERIOR SERVICE STANDARDS

Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets our strict standards – from the individual components to the actual finished product.

TOTAL QUALITY ASSURANCE SYSTEM

Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers receive only the best quality goods – of high reliability and durability. Our total quality system has been audited and approved by globally recognized bodies.

ABOUT US - COMPANY PROFILE

Page 5: PROLINK POWER BACKUP SOLUTION

4

Professional I Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Professional I Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses microprocessor controlled online double conversion technology to optimize system reliability. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. High input power factor correction in the system improves efficiency and reduce overall losses.

PROLiNK Professional I (1P/1P) Series is available in capacities ranging from 1KVA to 3KVA. The unit is equipped with LED Indication and RS232 communication port for status and alarm monitoring.

For business application that requires extended backup time, Professional I long run UPS models are available by using external battery bank.

PRO900-VS/VL SERIES 1-3KVA

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.8

• Wide input voltage (110 V – 300 V)

• Converter mode available

• ECO mode for energy saving

• Generator compatible

• Smart RS-232 communication port

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

Page 6: PROLINK POWER BACKUP SOLUTION

5

Professional I Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Professional I Series (1P/1P) is an advanced yet affordable single-phase UPS system that uses microprocessor controlled online double conversion technology to optimize system reliability. It is designed to protect against power outages, disturbances and spikes, making them most suitable for voltage fluctuating environments. High input power factor correction in the system improves efficiency and reduce overall losses.

PROLiNK Professional I (1P/1P) Series is available in capacities ranging from 1KVA to 3KVA. The unit is equipped with LED Indication and RS232 communication port for status and alarm monitoring.

For business application that requires extended backup time, Professional I long run UPS models are available by using external battery bank.

PRO900-VS/VL SERIES 1-3KVA

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.8

• Wide input voltage (110 V – 300 V)

• Converter mode available

• ECO mode for energy saving

• Generator compatible

• Smart RS-232 communication port

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

ONLINE UPS

Rear Panel

1. AC input2. Input circuit breaker3. RS-232 communication port4. External battery connection (Only available for L model)

5. Output receptacles6. Output terminal (Only available for 3KVA)

1-3KVA

3

2

5

1

3

25

4

1

PRO901-VS PRO901-VL

3

2

5

1

3

2

5

61

3

2 5

4

1

3

2

65

4

1

PRO903-VS PRO903-VL

PRO902-VS PRO902-VL

Page 7: PROLINK POWER BACKUP SOLUTION

6

MODEL PRO901-VS/VL PRO902-VS/VL PRO903-VS/VLPHASE Single phase with groundCAPACITY * 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 WINPUTNominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC

Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC or 160-280VAC (Based on load at 100%)

Frequency Range 40Hz ~ 70 HzPower Factor ≧ 0.99 @ Nominall Voltage (100% load)OUTPUTOutput Voltage 100/110/115/120/127VAC or 200/208/220/230/240VACVoltage Regulation ± 1 %Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 HzFrequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero Inverter to Bypass 4 ms (Typical)

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 88% 90%Battery Mode 83% 85% 88%BATTERY

Standard Model

Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 AhNumbers 2 4 6Typical Recharge Time 4 hours recover to 90% capacityCharging Current (max.) 1 A

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1%

Long-run Model **

Battery Type Depending on the capacity of external batteriesNumbers 2 3 4 6 8 6 8Charging Current (max.) 1A/2A/4A/6A (Adjustable)Charging Voltage 27.4VDC ± 1% 41.0VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 109.4VDC ±1% 82.1 VDC ±1% 109.4VDC ±1%

INDICATORSLED Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARMBattery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continuously sounding

PHYSICAL

Standard Model

421 x 190 x 318Net Weight (kgs) 9.8 17 27.6

Long-run Model **

282 x 145 x 220 397 x 145 x 220Net Weight (kgs) 4.1 6.8 7.4

ENVIRONMENT

Humidity 20-90 % RH @ 0- 40°C (Non-condensing)

Noise Level Less than 50dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC**Long-run model is only available in 200/208/220/230/240VAC systems * Product specifications are subject to change without further notice

Full Specifications

ONLINE UPS

Dimension, D x W x H (mm)

Dimension, D x W x H (mm)

282 x 145 x 220 397 x 145 x 220

Page 8: PROLINK POWER BACKUP SOLUTION

7

MODEL PRO901-VS/VL PRO902-VS/VL PRO903-VS/VLPHASE Single phase with groundCAPACITY * 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 WINPUTNominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC

Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC or 160-280VAC (Based on load at 100%)

Frequency Range 40Hz ~ 70 HzPower Factor ≧ 0.99 @ Nominall Voltage (100% load)OUTPUTOutput Voltage 100/110/115/120/127VAC or 200/208/220/230/240VACVoltage Regulation ± 1 %Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 HzFrequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero Inverter to Bypass 4 ms (Typical)

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 88% 90%Battery Mode 83% 85% 88%BATTERY

Standard Model

Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 AhNumbers 2 4 6Typical Recharge Time 4 hours recover to 90% capacityCharging Current (max.) 1 A

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1%

Long-run Model **

Battery Type Depending on the capacity of external batteriesNumbers 2 3 4 6 8 6 8Charging Current (max.) 1A/2A/4A/6A (Adjustable)Charging Voltage 27.4VDC ± 1% 41.0VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 109.4VDC ±1% 82.1 VDC ±1% 109.4VDC ±1%

INDICATORSLED Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARMBattery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continuously sounding

PHYSICAL

Standard Model

421 x 190 x 318Net Weight (kgs) 9.8 17 27.6

Long-run Model **

282 x 145 x 220 397 x 145 x 220Net Weight (kgs) 4.1 6.8 7.4

ENVIRONMENT

Humidity 20-90 % RH @ 0- 40°C (Non-condensing)

Noise Level Less than 50dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC

*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC**Long-run model is only available in 200/208/220/230/240VAC systems * Product specifications are subject to change without further notice

Full Specifications

ONLINE UPS

Dimension, D x W x H (mm)

Dimension, D x W x H (mm)

282 x 145 x 220 397 x 145 x 220

Professional II Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Professional II Series (1P/1P) is a single-phase UPS system using microprocessor controlled true online double conversion technology and it can be used to provide protection for critical loads especially on IT applications. High input power factor correction in the system improves efficiency and reduces overall losses.

PROLiNK Professional II series (1P/1P) Tower Type is available in capacities ranging from 1KVA to 10KVA. Users can easily monitor and access to their UPS status from a comprehensive LCD display. Both Tower and Rack Types of UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Adjustable battery number option is available from 6KVA and 10KVA long-run UPS models. In addition, Emergency Power Off (EPO) function is also available for 6KVA and 10KVA models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO900-WS/WL SERIES 1-10KVA

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.8

• Wide input voltage (110 V – 300 V)

• Converter mode available

• ECO mode for energy saving (Only available for 1-3KVA models)

• Generator compatible

• Adjustable battery number (Only available for 6-10KVA long-run models)

• Smart SNMP works well with either USB or RS-232 together

• Emergency power off function (EPO) (Only available for 6-10KVA models)

• Optional isolation transformer available

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

Page 9: PROLINK POWER BACKUP SOLUTION

8

ONLINE UPS

Rear Panel

1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port

5. Intelligent slot6. External battery connection (only available for L model)

7. Output receptacles8. Output circuit breaker9. Output terminal

3

4

1

2

7

5

PRO901-WS

3

1

2

5

7

4

PRO902-WS

12

7

3 5

4

9

PRO903-WS

12 7

3 5

4

89

6

PRO903-WL

Rear Panel

PRO906-WL / PRO910-WL

4

2

3

5

9

7

8

1

6

PRO906-WS / PRO910-WS

4

21

6

3

5

9

7

8

6-10KVA

1-3KVA

1

2 7

3 5

4 6

PRO901-WL

7

PRO902-WL

1

2

3

4

5

6

1. External battery connector2. RS-232 communication port3. Intelligent slot4. USB Communication port5. Emergency power off function connector (EPO connector)6. Cooling fan7. Input circuit breaker8. Input/Output terminal 9. Maintenance bypass switch (Optional)

Page 10: PROLINK POWER BACKUP SOLUTION

9

MODEL PRO901-WS/WL PRO902-WS/WL PRO903-WS/WL PRO906-WS/WL PRO910-WS/WLPHASE Single phase with groundCAPACITY * 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000VA / 4800W 10000 VA / 8000 WINPUTNominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC

Input Voltage Range 55-150 VAC or 110-300 VAC (Based on load at 50%)85-140VAC or 160-280VAC (Based on load at 100%)

110-300 VAC (Based on load at 50%)176-300 VAC (Based on load at 100%)

Frequency Range 40 Hz ~ 70 Hz 46~54 Hz or 56~64 HzPower Factor ≧0.99 @ Nominall Voltage (100% load)OUTPUTOutput Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACVoltage Regulation ± 1 %Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 HzFrequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz or 60Hz ± 0.1 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load)

≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero Inverter to Bypass 4 ms (Typical) Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 88% 90% 92% 93%Battery Mode 83% 87% 88% 90% 91%BATTERY

Standard Model

Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 AhNumbers 2 4 6 16 20 16 20Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current (max.) 1 A 1 A / 2 A

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 273VDC ±1% 218.4 VDC

±1% 273VDC ±1%

Long-run Model **

Battery Type Depending on the capacity of external batteriesNumbers 2 3 4 6 8 6 8 16 ~ 20 (Adjustable)

Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)

Charging Voltage 27.4VDC ± 1%

41.0VDC ± 1%

54.7VDC ±1%

82.1 VDC ±1%

109.4VDC ±1%

82.1 VDC ±1%

109.4VDC ±1% 273 VDC ±1% (Based on 20pcs batteries)

INDICATORSLCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 369 x 190 x 688 442 x 190 x 688Net Weight (kgs) 9.8 17 27.6 61 74 66 76

Long-run Model **

282 x 145 x 220 397 x 145 x 220 369 x 190 x 318 442 x 190 x 318Net Weight (kgs) 4.1 6.8 7.4 12 16

ENVIRONMENT

Humidity 20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH @ 0-50°C (non-condensing)

0-95% RH @ 0-40°C (non-condensing)

Noise Level Less than 50dB @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC. 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC.**Long-run model is only available for 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA).

Full Specifications

ONLINE UPS

Dimension, DxWxH (mm)

Dimension, DxWxH (mm)

Page 11: PROLINK POWER BACKUP SOLUTION

10

Professional II Series (1P/1P)-Rack

ONLINE UPS

PROLiNK Professional II Series (1P/1P) is a single-phase UPS system using microprocessor controlled true online double conversion technology and it can be used to provide protection for critical loads especially on IT applications. High input power factor correction in the system improves efficiency and reduces overall losses.

PROLiNK Professional II series (1P/1P) Rack Type is available in capacities ranging from 1KVA to 10KVA. Users can easily monitor and access to their UPS status from a comprehensive LCD display. Both Tower and Rack Types of UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Adjustable battery number option is available from 6KVA and 10KVA long run UPS models. In addition, Emergency Power Off (EPO) function is also available for 6KVA and 10KVA models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO900-WRS/WRL SERIES 1-10KVA

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.8

• Wide input voltage range (110-300 VAC)

• Converter mode available

• ECO mode for energy saving (Only available for 1-3KVA models)

• Generator compatible

• Adjustable charging current via LCD or software (1A~6A)

• Emergency power off function (EPO) (Only available for 6-10KVA models)

Work-Stations Servers 19” Rack Mount

Local AreaNetwork (LAN)

Small ComputerNetwork

Page 12: PROLINK POWER BACKUP SOLUTION

11

Professional II Series (1P/1P)-Rack

ONLINE UPS

PROLiNK Professional II Series (1P/1P) is a single-phase UPS system using microprocessor controlled true online double conversion technology and it can be used to provide protection for critical loads especially on IT applications. High input power factor correction in the system improves efficiency and reduces overall losses.

PROLiNK Professional II series (1P/1P) Rack Type is available in capacities ranging from 1KVA to 10KVA. Users can easily monitor and access to their UPS status from a comprehensive LCD display. Both Tower and Rack Types of UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Adjustable battery number option is available from 6KVA and 10KVA long run UPS models. In addition, Emergency Power Off (EPO) function is also available for 6KVA and 10KVA models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO900-WRS/WRL SERIES 1-10KVA

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.8

• Wide input voltage range (110-300 VAC)

• Converter mode available

• ECO mode for energy saving (Only available for 1-3KVA models)

• Generator compatible

• Adjustable charging current via LCD or software (1A~6A)

• Emergency power off function (EPO) (Only available for 6-10KVA models)

Work-Stations Servers 19” Rack Mount

Local AreaNetwork (LAN)

Small ComputerNetwork

Rear Panel

1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port

1-3KVA

6-10KVA

5. Intelligent slot6. External battery connection (only available for L model)7. Output receptacles8. Output terminal

1. External battery connector2. RS-232 communication port3. Intelligent slot4. USB communication port

5. Emergency power off function connector (EPO connector)6. Input circuit breaker7. Input/Output terminal

PRO906-WRS/WRL PRO910-WRS/WRL

ONLINE UPS

PRO901-WRS

1

2 5 3

4

7

PRO902-WRL

7 1 3 4

2 5 6

PRO903-WRL

7 1 3 4

652

8

PRO901-WRL

7 1

2 5 6

3 4

7 6

31452

7 6

3 1452

PRO902-WRS

2 3 5

1 4 7

PRO903-WRS

2 4 7

1 5 3 8

Page 13: PROLINK POWER BACKUP SOLUTION

12

Full Specifications

ONLINE UPS

MODEL PRO901-WRS/WRL PRO902-WRS/WRL PRO903-WRS/WRL PRO906-WRS/WRL PRO910-WRS/WRLPHASE Single phase with groundCAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 WINPUT Nominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC

Input Voltage Range 55-145 VAC or 110-300 VAC at 50% load85-140 VAC or 160-280 VAC at 100% load

110-300 VAC ± 3% at 50% Load176-300 VAC ± 3% at 100% Load

Frequency Range 40Hz ~ 70 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 HzPower Factor ≧ 0.99 @ Nominal Voltage (100% load)OUTPUTOutput Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACVoltage Regulation ± 1% ± 1%Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 HzFrequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦3 % THD (Linear Load), ≦6 % THD (Non-linear Load)

≦3 % THD (Linear Load), ≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero 0 msInverter to Bypass 4 ms (Typical) 0 ms

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 89% 90% 92% 93%Battery Mode 83% 87% 88% 90% 91%BATTERY

Standard Model

Battery Type 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 12 V / 9 AHNumbers 2 4 6 16 20 16 20Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current 1.0 A 1A/2A (Adjustable)

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4VDC ± 1%

273 VDC ± 1%

218.4VDC ± 1%

273 VDC ± 1%

Long-run Model

Battery Type Depending on the capacity of external batteries Depending on applicationsNumbers 2 3 4 6 8 6 8 16 - 20 pcs (Adjustable)

Charging Current (max.) 1.0A/2.0A/4.0A/6.0 A 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)

Charging Voltage 27.4VDC ± 1%

41.0VDC ± 1%

54.7 VDC ±1%

82.1 VDC ±1%

109.4VDC ±1%

82.1 VDC ±1%

109.4VDC ±1% 218.4 VDC ± 1% (Based on 16pcs batteries)

INDICATORSLCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

ALARMBattery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continuously sounding

PHYSICAL

StandardModel

Dimension, D x W x H (mm)

Dimension, D x W x H (mm)

310 x 438 x 88 [2U] 410 x 438 x 88 [2U] 630 x 438 x 88 [2U]

UPS Unit: 530x438x88

[2U]Battery Pack: 668x438x88

[2U]]

UPS Unit: 530x438x88

[2U]Battery Pack: 580x438x133

[3U]]

UPS Unit: 580x438x133[3U]

Battery Pack: 580x438x133[3U]

Net Weight (kgs) 12 19 29.3UPS Unit: 15Battery Pack:

48

UPS Unit: 15Battery Pack:

61

UPS Unit: 18Battery Pack:

51

UPS Unit: 18Battery Pack:

61Long-run Model*

310 x 438 x 88 [2U] 410 x 438 x 88 [2U] 530 x 438 x 88 [2U] 580 x 438 x 133 [3U]Net Weight (kgs) 9 12 14.2 15 18

ENVIRONMENTHumidity 20-90 % RH @ 0- 40°C (non-condensing) 0-95 % RH @ 0- 40°C (non-condensing)Noise Level Less than 50dB @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

*Long-run model is only available for 200/208/220/230/240VAC systems.**Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC.

Page 14: PROLINK POWER BACKUP SOLUTION

13

Professional II Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Professional II Series (3P/1P) is a three-phase input online UPS system which is designed to provide clean power for critical devices especially on IT application. The unit is equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

PROLiNK Professional II Series (3P/1P) is available in capacities ranging from 10KVA to 20KVA. Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

In addition, Emergency Power Off (EPO) function is also available for the models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO93100-WS/WL SERIES 10-20KVA

ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

• True double-conversion

• Output power factor 0.8

• Wide input voltage range

• 50Hz frequency converter mode

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for optimized

battery performance

• Optional maintenance bypass switch

Page 15: PROLINK POWER BACKUP SOLUTION

14

ONLINE UPS

Rear Panel

1. External battery connector 2. RS-232 communication port3. Intelligent slot4. USB communication port5. Emergency power off function connector (EPO connector)6. Cooling fan7. Input circuit breaker8. Maintenance bypass switch (Optional)9. Output terminal10. Grounding terminal11. Utility input terminal

10-20KVA

3

5

8

7

1

4

6

2

PRO93115-WL/PRO93120-WL

9 10 11

35

8

7

9 10 11

1

4

6

2

PRO93110-WL

3

5

8

7

1

4

6

2

PRO93115-WS/PRO93120-WS

3

5

8

7

1

4

6

2

PRO93110-WS

9 10 119 10 11

Page 16: PROLINK POWER BACKUP SOLUTION

15

ONLINE UPS

Rear Panel

1. External battery connector 2. RS-232 communication port3. Intelligent slot4. USB communication port5. Emergency power off function connector (EPO connector)6. Cooling fan7. Input circuit breaker8. Maintenance bypass switch (Optional)9. Output terminal10. Grounding terminal11. Utility input terminal

10-20KVA

3

5

8

7

1

4

6

2

PRO93115-WL/PRO93120-WL

9 10 11

35

8

7

9 10 11

1

4

6

2

PRO93110-WL

3

5

8

7

1

4

6

2

PRO93115-WS/PRO93120-WS

3

5

8

7

1

4

6

2

PRO93110-WS

9 10 119 10 11

Full Specifications

ONLINE UPS

MODEL PRO93110-WS/WL PRO93115-WS/WL PRO93120-WS/WLPHASE 3 phase in / 1 phase outCAPACITY 10000 VA / 8000 W 15000 VA / 12000 W 20000 VA / 16000 WINPUT Nominal Voltage 3 x 400 VAC (3Ph+N)

Voltage Range 190-520 VAC (3-phase) @ 50% load305-520 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz OUTPUTOutput Voltage 208/220/230/240VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz Current Crest Ratio 3:1 (max.)Harmonic Distortion ≦3 % THD (Linear Load) ; ≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 91% 91% 91%Battery Mode 91% 91% 91% BATTERY

Standard Model

Battery Type 12 V / 9 AHNumbers 16 pcs 20 pcs 16 pcs 20 pcs 16 pcs x 2 strings 20 pcs x 2 stringsTypical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1A ± 10% 1A/2A/4A ± 10% (2A default)Charging Voltage 218.4 VDC ± 1% 273 VDC ± 1% 218.4 VDC ± 1% 273 VDC ± 1% 218.4 VDC ± 1% 273 VDC ± 1%

Long-run Model

Battery Type Depending on the capacity of external batteriesNumbers 16 pcs 20 pcs 16 pcs 20 pcs 16 pcs 20 pcsCharging Current (max.) 4A Default, 1A/2A/4A (Adjustable)Charging Voltage 218.4 VDC ± 1% 273 VDC ± 1% 218.4 VDC ± 1% 273 VDC ± 1% 218.4 VDC ± 1% 273 VDC ± 1%

INDICATORSLCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

StandardModel

Dimension, D x W x H mm) 442 x 190 x 688 442 x 190 x 688 815 x 250x 826Net Weight (kgs) 66 76 67 78 125 145

Long-run Model

Dimension, D x W x H (mm) 442 x 190 x 318 575 x 190 x 318Net Weight (kgs) 15 16 18.95

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 50°C (Non-condensing)Noise Level Less than 60dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

Page 17: PROLINK POWER BACKUP SOLUTION

16

Professional II+ Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Professional II+ Tower Series (1P/1P) is a single-phase UPS system with output power factor 0.9. The system design is based on microprocessor controlled true online double conversion technology to optimize system reliability. The unit is able to provide protection for critical loads especially on IT applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

PROLiNK Professional II+ Tower Series is available in capacities ranging from 1KVA to 10KVA. Long run models are only available from 6KVA to 10KVA. Adjustable battery number option is available for 6KVA and 10KVA long run models.

In addition, Emergency Power Off (EPO) function is also available for 6KVA and 10KVA models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO900-ES/EL SERIES 1-10KVA

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.9

• Wide input voltage

• Converter mode available

• ECO mode for energy saving (Only available for 1-3KVA models)

• Adjustable battery numbers

• Generator compatible

• Smart SNMP works well with either USB or RS-232 together

• Comprehensive display allows easy monitoring and access of UPS status

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

Page 18: PROLINK POWER BACKUP SOLUTION

17

• True double-conversion

• Microprocessor control optimizes reliability

• Input power factor correction

• Output power factor 0.9

• Wide input voltage

• Converter mode available

• ECO mode for energy saving (Only available for 1-3KVA models)

• Adjustable battery numbers

• Generator compatible

• Smart SNMP works well with either USB or RS-232 together

• Comprehensive display allows easy monitoring and access of UPS status

ONLINE UPS

Rear Panel

1. AC input2. Input circuit breaker3. USB communication port4. RS-232 communication port

5. Intelligent slot6. Output receptacles7. Output terminal

Rear Panel

PRO906-EL / PRO910-ELPRO906-ES / PRO910-ES

1. External battery connector2. RS-232 communication port3. Intelligent slot4. USB communication port5. Emergency power off function connector (EPO connector)6. Cooling fan7. Input circuit breaker8. Input/Output terminal 9. Maintenance bypass switch (Optional)

6-10KVA

1-3KVA

PRO901-ES

6

1

2

4

3 5

PRO903-ES

1

2

4

3

6

7

5

PRO902-ES

6

4

3

1

2

5

4

2

3

5

9

7

8

1

6

4

21

6

3

5

9

7

8

Page 19: PROLINK POWER BACKUP SOLUTION

18

MODEL PRO901-ES PRO902-ES PRO903-ES PRO906-ES/EL PRO910-ES/ELPHASE Single phase with groundCAPACITY * 1000 VA / 900 W 2000 VA / 1800 W 3000 VA / 2700 W 6000 VA / 5400 W 10000 VA / 9000 WINPUTNominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC

Input Voltage Range 60-150 VAC or 120-300 VAC (Based on load at 50%) 90-140 VAC or 180-280 VAC (Based on load at 100%)

110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%)

Frequency Range 40Hz ~ 70 Hz 46~54 Hz or 56~64 HzPower Factor ≧0.99 @ Nominall Voltage (100% load)OUTPUTOutput Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACVoltage Regulation ± 1 %Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 HzFrequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.5% 50 Hz or 60Hz ± 0.1 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load)

≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero Inverter to Bypass 4 ms (Typical) Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 89% 90% 92% 93%Battery Mode 83% 85% 88% 90% 91%BATTERY

Standard Model

Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 AhNumbers 2 4 6 16 20 16 20Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current (max.) 1 A 1 A / 2 A

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 273VDC ±1% 218.4 VDC

±1% 273VDC ±1%

Long-run Model **

Battery Type Depending on the capacity of external batteriesNumbers 16 ~ 20 (Adjustable)

Charging Current (max.)

N/AN/A

N/A

N/A

N/AN/A

1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)

Charging Voltage 273 VDC ±1% (Based on 20pcs batteries)INDICATORSLCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 369x190x688 442 x 190 x 688Net Weight (kgs) 9.8 17 27.6 61 74 66 76

Long-run Model **

369 x 190 x 318 442 x 190 x 318Net Weight (kgs) 12 16

ENVIRONMENT

Humidity 20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH @ 0-40°C (non-condensing)

Noise Level Less than 50dB @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACOptional SNMP Power management from SNMP manager and web browser

*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC. 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC.**Long-run model is only available for 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA).

Full Specifications

ONLINE UPS

Dimension, DxWxH (mm)

Dimension, DxWxH (mm)

Page 20: PROLINK POWER BACKUP SOLUTION

19

MODEL PRO901-ES PRO902-ES PRO903-ES PRO906-ES/EL PRO910-ES/ELPHASE Single phase with groundCAPACITY * 1000 VA / 900 W 2000 VA / 1800 W 3000 VA / 2700 W 6000 VA / 5400 W 10000 VA / 9000 WINPUTNominal Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VAC

Input Voltage Range 60-150 VAC or 120-300 VAC (Based on load at 50%) 90-140 VAC or 180-280 VAC (Based on load at 100%)

110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%)

Frequency Range 40Hz ~ 70 Hz 46~54 Hz or 56~64 HzPower Factor ≧0.99 @ Nominall Voltage (100% load)OUTPUTOutput Voltage 100/110/115/120/127VAC or 200/208/220/230/240VAC 208/220/230/240VACVoltage Regulation ± 1 %Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 HzFrequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.5% 50 Hz or 60Hz ± 0.1 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load)

≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero Inverter to Bypass 4 ms (Typical) Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 89% 90% 92% 93%Battery Mode 83% 85% 88% 90% 91%BATTERY

Standard Model

Battery Type 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 AhNumbers 2 4 6 16 20 16 20Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current (max.) 1 A 1 A / 2 A

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4 VDC ±1% 273VDC ±1% 218.4 VDC

±1% 273VDC ±1%

Long-run Model **

Battery Type Depending on the capacity of external batteriesNumbers 16 ~ 20 (Adjustable)

Charging Current (max.)

N/AN/A

N/A

N/A

N/AN/A

1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)

Charging Voltage 273 VDC ±1% (Based on 20pcs batteries)INDICATORSLCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

282 x 145 x 220 397 x 145 x 220 421 x 190 x 318 369x190x688 442 x 190 x 688Net Weight (kgs) 9.8 17 27.6 61 74 66 76

Long-run Model **

369 x 190 x 318 442 x 190 x 318Net Weight (kgs) 12 16

ENVIRONMENT

Humidity 20-90 % RH @ 0- 40°C (Non-condensing) 0-95% RH @ 0-40°C (non-condensing)

Noise Level Less than 50dB @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACOptional SNMP Power management from SNMP manager and web browser

*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC. 6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC.**Long-run model is only available for 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA).

Full Specifications

ONLINE UPS

Dimension, DxWxH (mm)

Dimension, DxWxH (mm)

Professional II+ Series (1P/1P)-Rack

ONLINE UPS

PROLiNK Professional II+ Rack/Tower Series (1P/1P) is a single-phase UPS system with output power factor improvement to 0.9. The system design is based on microprocessor controlled true online double conversion technology which can be used for IT applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

The front panel LCD display comes with rotation feature for both rack and tower types. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

PROLiNK Professional II+ Rack/ Tower Series is available in capacities ranging from 1KVA to 10KVA. Long run models are only available from 6KVA to 10KVA. Adjustable battery number option is available for 6KVA and 10KVA long run models.

In addition, Emergency Power Off (EPO) function is also available for 6KVA and 10KVA models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO900-ERS/ERL SERIES 1-10KVA

• True double-conversion• Microprocessor control optimizes reliability• Input power factor correction• Output power factor 0.9• Wide input voltage range• Converter mode available

• ECO mode for energy saving (Only available for 1-3KVA models)• Generator compatible• Adjustable charging current via LCD or software (1A~6A)• Emergency power off function (EPO) (Only available for 6K/10K models)• Comprehensive display allows easy monitoring and access of UPS status

Work-Stations Servers 19” Rack Mount

Local AreaNetwork (LAN)

Small ComputerNetwork

Page 21: PROLINK POWER BACKUP SOLUTION

20

Rear Panel

1. AC input

2. Input circuit breaker

3. USB communication port

4. RS-232 communication port

1-3KVA

6-10KVA

5. Intelligent slot

6. Output receptacles

7. Output terminal

8. Cooling fan

1. External battery connector

2. RS-232 communication port

3. Intelligent slot

4. USB communication port

5. Emergency power off function connector (EPO connector)

6. Input circuit breaker

7. Input/Output terminal

ONLINE UPS

PRO903-ERS/ERL

PRO902-ERS/ERL

2

1 4

38 5 6

PRO901-ERS/ERL

2

1 4

35 6

1

2 48

35 6 7

PRO910-ERS/ERL

3 1

7 6

5 42

PRO906-ERS/ERL 7 6

315 42

Page 22: PROLINK POWER BACKUP SOLUTION

21

Rear Panel

1. AC input

2. Input circuit breaker

3. USB communication port

4. RS-232 communication port

1-3KVA

6-10KVA

5. Intelligent slot

6. Output receptacles

7. Output terminal

8. Cooling fan

1. External battery connector

2. RS-232 communication port

3. Intelligent slot

4. USB communication port

5. Emergency power off function connector (EPO connector)

6. Input circuit breaker

7. Input/Output terminal

ONLINE UPS

PRO903-ERS/ERL

PRO902-ERS/ERL

2

1 4

38 5 6

PRO901-ERS/ERL

2

1 4

35 6

1

2 48

35 6 7

PRO910-ERS/ERL

3 1

7 6

5 42

PRO906-ERS/ERL 7 6

315 42

Full Specifications

ONLINE UPS

MODEL PRO901-ERS/ERL PRO902-ERS/ERL PRO903-ERS/ERL PRO906-ERS/ERL PRO910-ERS/ERLPHASE Single phase with groundCAPACITY 1000 VA / 900 W 2000 VA / 1800 W 3000 VA / 2700 W 6000 VA / 5400 W 10000 VA / 9000 WINPUT Nominal Voltage 110/115/120/127VAC or 208/220/230/240VAC 208/220/230/240VAC

Input Voltage Range 60-145 VAC or 120-300 VAC at 50% load 90-145 VAC or 180-300 VAC at 100% load

110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%)

Frequency Range 40Hz ~ 70 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 HzPower Factor ≧ 0.99 @ Nominal Voltage (100% load)OUTPUTOutput Voltage 110/115/120/127VAC or 208/220/230/240VAC 208/220/230/240VACVoltage Regulation ± 1% ± 1%Frequency Range (Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 HzFrequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦3 % THD (Linear Load), ≦6 % THD (Non-linear Load)

≦3 % THD (Linear Load), ≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode Zero 0 msInverter to Bypass 4 ms (Typical) 0 ms

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 88% 89% 90% 92% 93%Battery Mode 83% 87% 88% 90% 91%BATTERY

Standard Model

Battery Type 12 V / 9 AH 12 V / 9 AH 12 V / 9 AH 12 V / 9 AHNumbers 2 4 6 16 20 16 20Typical Recharge Time 4 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current 1.0 A 1A/2A (Adjustable)

Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% 218.4VDC ± 1%

273 VDC ± 1%

218.4VDC ± 1%

273 VDC ± 1%

Long-run Model

Battery Type N/A Depending on applicationsNumbers N/A 16 - 20 pcs (Adjustable)

Charging Current (max.) N/A

N/A

1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries)

Charging Voltage 218.4 VDC ± 1% (Based on 16pcs batteries)

INDICATORSLCD Panel Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARMBattery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continuously sounding

PHYSICAL

StandardModel

Dimension, D x W x H (mm)

Dimension, D x W x H (mm)

310 x 438 x 88 [2U] 410 x 438 x 88 [2U] 630 x 438 x 88 [2U]

UPS Unit: 500x438x88

[2U]Battery Pack: 668x438x88

[2U]]

UPS Unit: 500x438x88

[2U]Battery Pack: 580x438x133

[3U]]

UPS Unit: 580x438x133[3U]

Battery Pack: 580x438x133[3U]

Net Weight (kgs) 12 19 29.3UPS Unit: 15Battery Pack:

48

UPS Unit: 15Battery Pack:

61

UPS Unit: 18Battery Pack:

51

UPS Unit: 18Battery Pack:

61Long-run Model*

N/A 500 x 438 x 88[2U] 580 x 438 x 133[3U]Net Weight (kgs) N/A 15 18

ENVIRONMENTHumidity 20-90 % RH @ 0- 40°C (non-condensing) 0-95 % RH @ 0- 40°C (non-condensing)Noise Level Less than 50dB @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACOptional SNMP Power management from SNMP manager and web browser

*1K-3K: Derate to 80% of capacity in Frequency converter mode or when the output voltage is adjusted to 208VAC. 6K/10K: Derate to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC.* Product specifications are subject to change without further notice

Page 23: PROLINK POWER BACKUP SOLUTION

22

Master II Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Master II Series (1P/1P) Tower Type is a single-phase UPS system that employs a true online double-conversion technology. UPS system is designed to deliver clean and high quality electrical power to fully protect critical devices such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

UPS is equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

The Master II series (1P/1P) Tower p.f 0.9 Type is available in capacities ranging from 1KVA to 3KVA. Programmable power outlet feature is implemented in the system so that during power failure, this enables users to extend battery time to critical devices by shutting down the non-critical devices.

In addition, Emergency Power Off (EPO) function is also available for UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO800-ES/EL SERIES 1-3KVA

• True double-conversion online UPS• Wide input voltage range (110-300 VAC, 55-150 VAC) • Input power factor correction 0.99• Output power factor 0.9• 50/60 Hz Frequency Converter Mode • Programmable power management outlets• Emergency power off function (EPO) • ECO mode operation for energy saving• Very high surge immunity up to 7KV, 13KA, 1300J• Generator compatible

• High overload capability and enhanced short circuit protection• SNMP/USB/RS-232 multiple communications• 3-stage smart charging design • Maximum 8A extended parallel control available for long run model • Selectable output voltage: 200-240VAC, 100-127VAC• Laser printer and ultrasound system load acceptable

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 24: PROLINK POWER BACKUP SOLUTION

23

ONLINE UPS

Rear Panel

1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO) 7. USB communication port

8. RS-232 communication port9. Intelligent slot10. External battery connection (Only available for L model) 11. Output terminal 12. Output circuit breaker 13. Cooling fan

1-3KVA

PRO803-EL

7

8

9

10

12

11

1

6 5

4

3

2

13

PRO803-ES

7

8

9

10

11

1

6 5

4

3

2

1213

PRO801-ESPRO8015-ES

7

8

9

10

1

65

13

4

32

PRO802-EL

7

8

9

10

1

6 5

4

32

13

PRO802-ES

7

8

9

10

1

6 5

4

32

13

7

8

9

10

1

6

5

4

32

PRO801-ELPRO8015-EL

13

Page 25: PROLINK POWER BACKUP SOLUTION

24

Full Specifications

ONLINE UPS

MODEL PRO801-ES/EL PRO8015-ES/EL PRO802-ES/EL PRO803-ES/ELPHASE Single phase with groundCAPACITY 1000 VA / 900 W 1500 VA / 1350 W 2000 VA / 1800 W 3000 VA / 2700 WINPUTNominal Voltage 100/110/115/120/127 VAC or 200/208/220/230/240 VAC

Voltage Range 55 - 150 VAC ± 5 % or 110 - 300 VAC ± 5 % at 50% load80 - 150 VAC ± 5 % or 160 - 300 VAC ± 5 % at 100% load

Frequency Range 40 Hz ~ 70 HzPower Factor ≧ 0.99 @ Nominal Voltage (100% Load)

THDi ≦ 5% @100~130VAC or 205-245VAC THDU < 1.6% @ input and full linear load condition with battery fully charged

OUTPUTOutput Voltage 100/110/115/120/127 VAC or 200/208/220/230/240 VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 47~53 Hz or 57~63 HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 HzCurrent Crest Ratio 3:1Harmonic Distortion ≦2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass 4 ms (Typical)

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90% 91%ECO Mode 97%Battery Mode 89% 89% 89% 90%BATTERY

Standard Model

Battery Type 12 V / 7 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah 12 V / 7 AhNumbers 3 3 6 6 8Typical Recharge Time 4 hours recover to 90% capacityCharging Current (max.) 1.5 ACharging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% 109.6 VDC ± 1%

Long-run Model

Battery Type Depending on the capacity of external batteriesNumbers 3 3 6 6 8Charging Current (max.) 1A/2A/4A/6A/8A (Selectable via LCD setting)Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% 109.6 VDC ± 1%

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 5 secondsLow Battery Sounding every 2 secondsOverload Sounding every secondFault Continuously soundingPHYSICAL

Standard Model

Dimension, D x W x H (mm) 397 x 145 x 220 421 x 190 x 318Net Weight (kgs) 12.5 13.8 25.8 27 32.8

Long-run Model

Dimension, D x W x H (mm) 397 x 145 x 220 421 x 190 x 318Net Weight (kgs) 5.8 5.8 12 13.8 13.8

ENVIRONMENTHumidity 20-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 50dB @1MeterMANAGEMENTSmart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser*Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100VAC,200VAC or 208 VAC.**L means long-run model.

Page 26: PROLINK POWER BACKUP SOLUTION

25

Master II Series (1P/1P)-Tower

ONLINE UPS

PRO800-QS/QL SERIES 1-10KVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

• True double-conversion • Microprocessor control optimizes reliability* • Output power factor 1• Input power factor correction • Wide input voltage (110V–300V) • 50/60Hz Frequency Converter Mode• ECO mode energy saving*• Emergency power off (EPO) function• Provides over voltage cut-off protection and surge immunity by MOV for full time equipment protection*

• Low input THDi to reduce power system pollution• Adjustable charging current via LCD panel*• Generator compatible• DSP technology guarantees high performance• Wide input voltage range (110-300 VAC)• Active input power factor correction 0.99• SNMP/USB/RS-232 communications• Optional N+X parallel redundancy• Optional OVCD protection

*Only available for 1-3KVA models Only available for 6-10KVA models

PROLiNK Master II Series (1P/1P) Tower Type is a new UPS system series with output power factor 1.0. The UPS design is using true online double-conversion technology which provides higher charging current and it can be set via LCD display. The system is designed to provide protection for critical loads such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

For 6KVA and 10KVA units, DSP control technology is implemented for the system to have improve performance and real time harmonic cancellation. UPS is equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time. External battery chargers and battery extension assembly are made available for longer runtime applications.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

The Master II series (1P/1P) Tower p.f 1.0 Type is available in capacities ranging from 1KVA to 10KVA. For those applications which require longer backup, long run models with adjustable battery number options are available for 6KVA and 10KVA. Parallel Redundant configuration (N+X) is available as an option for 6KVA and 10KVA units.

In addition, Emergency Power Off (EPO) function is also available for UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

Page 27: PROLINK POWER BACKUP SOLUTION

26

ONLINE UPS

Rear Panel

1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission-critical loads3. AC input4. Network/Fax/Modem surge protection5. USB communication port

6. RS-232 communication port7. Intelligent slot8. Emergency power off function connector (EPO)9. External battery connection 10. Cooling fan

1-3KVA

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Cooling fan

8. Maintenance bypass switch9. Input circuit breaker10. Output receptacles: connect to mission-critical loads11. Output circuit breaker for receptacles12. Output terminal: connect to mission-critical loads13. External battery connector 14. Utility input terminal

6-10KVA

PRO806-QS/PRO810-QS PRO806-QL/PRO810-QL

PRO802-QS

10

5

6

7

9

48

3

1

2

5

6

7

9

48

3

1

2

10

PRO803-QSPRO801-QS/PRO8015-QS

5

6

7

98

4

3

1

2

10

1 2 3 4

13

9

10

12 14

11

8

5

7

6

1 2 3 4

6

13

9

10

12 14

11

8

5

7

Page 28: PROLINK POWER BACKUP SOLUTION

27

ONLINE UPS

Rear Panel

1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission-critical loads3. AC input4. Network/Fax/Modem surge protection5. USB communication port

6. RS-232 communication port7. Intelligent slot8. Emergency power off function connector (EPO)9. External battery connection 10. Cooling fan

1-3KVA

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Cooling fan

8. Maintenance bypass switch9. Input circuit breaker10. Output receptacles: connect to mission-critical loads11. Output circuit breaker for receptacles12. Output terminal: connect to mission-critical loads13. External battery connector 14. Utility input terminal

6-10KVA

PRO806-QS/PRO810-QS PRO806-QL/PRO810-QL

PRO802-QS

10

5

6

7

9

48

3

1

2

5

6

7

9

48

3

1

2

10

PRO803-QSPRO801-QS/PRO8015-QS

5

6

7

98

4

3

1

2

10

1 2 3 4

13

9

10

12 14

11

8

5

7

6

1 2 3 4

6

13

9

10

12 14

11

8

5

7

ONLINE UPS

Full Specifications

MODEL PRO801-QS PRO8015-QS PRO802-QS PRO803-QSPHASE Single phase with groundCAPACITY* 1000 VA / 1000 W 1500 VA / 1500W 2000 VA / 2000 W 3000 VA / 3000 W

INPUT

Nominal Voltage

Voltage Range

100/110/115/120 /127 VAC or 200/208/220/230/240 VAC

55 - 150 VAC ± 3 % or 110 - 300 VAC ± 3 % at 50% load80 - 150 VAC ± 3 % or 160 - 300 VAC ± 3 % at 100% load

Frequency Range 40Hz ~ 70HzPower Factor ≧ 0.99 @ nominal voltage (100% load)THDi% ≦5%OUTPUTOutput Voltage 100*/110*/115*/120 /127 VAC or 200*/208*/220/230/240 VAC

AC Voltage Regulation (Batt. Mode) ± 1%

Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57~63Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz

Current Crest Ratio 3:1

Harmonic Distortion ≦2% THD (Linear Load), ≦4 % THD (Non-linear Load)

Transfer Time

AC to DC Zero

Inverter to Bypass 4 ms (Typical)

ECO to Battery Mode 8 ms (Typical), 10 ms (max)Waveform (Batt. Mode) Pure SinewaveEFFICIENCYLine Mode ≧89% @ battery fully charged ≧91% @ battery fully chargedECO Mode ≧96% @ battery fully chargedBattery Mode ≧88% ≧90%BATTERYBattery Type 12 V / 9 AH 12 V / 7 AH 12 V / 9 AH 12 V / 9 AH 12 V / 7 AH 12 V / 7 AH 12 V / 9AH 12 V / 7AHNumbers 2 3 3 4 6 8 6 8Typical Recharge Time 3 hours recover to 95% capacity for internal battery@ 2A charging current

Charging Current 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable200/208/220/230/240 VAC models: default 2A, max. 12A adjustable Default: 2A, Max: 8A adjustable

Charging Voltage 27.4VDC ± 1% 41.1VDC ± 1% 41.1VDC ± 1% 54.8VDC ± 1%

82.2VDC ± 1%

109.6VDC ± 1%

82.2VDC ± 1%

109.6 VDC ± 1%

INDICATORSLCD Panel Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicatorALARMBattery Mode Sounding every 5 secondsLow Battery Sounding every 2 secondsOverload Sounding every secondFault Continuously soundingPHYSICALDimension, D x W x H (mm) 397 x 145 x 220 421 x 190 x 318Net Weight (without battery) (kgs) 6.6 6.6 7 9.9 9.9 9.9 12.3 12.3Net Weight (w/ built-in battery) (kgs) 11.7 13 14.6 20.3 23.2 28.5 28 33ENVIRONMENTHumidity 20-95 % RH @ 0- 45°C (non-condensing)Noise Level Less than 50dBA @ 1 Meter with Fan speed controlMANAGEMENTSmart RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

*Derate capacity to 80% when the output voltage is adjusted to 100VAC/200VAC/208VAC.

Page 29: PROLINK POWER BACKUP SOLUTION

28

Full Specifications

ONLINE UPS

MODEL PRO806-QS/QL PRO810-QS/QLPHASE 1 phase in / 1 phase outCAPACITY 6000 VA / 6000 W 10000 VA / 10000 WINPUTNominal Voltage 208/220/230/240 VAC

Voltage Range110-300 VAC @ 0 ~60% load

140-300 VAC @ 60 ~ 80% load176-300 VAC @ 80 ~ 100% load

Frequency Range 46~54 Hz or 56~64 Hz Phase Single phase with groundPower Factor ≧ 0.99 @ full loadTHDi <4% @100% Load ; <6% @50% Load OUTPUTOutput Voltage 208/220/230/240 VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)Harmonic Distortion ≦1 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure Sinewave

OverloadAC Mode 100%~110% 10min ; 110%~130%: 1min ; >130% : 1secBattery Mode 100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec

EFFICIENCYAC Mode 94%Battery Mode 91%BATTERY

Standard Model

Battery Type 12 V / 7 Ah 12 V / 9 AhNumbers 16Typical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1.0 ACharging Voltage 218.4 VDC ± 1%

Long-run Model

Battery Type Depending on applicationsNumbers 16-20**Charging Current (max.) 4.0 ACharging Voltage 218.4 VDC ± 1% (Based on 16 pcs batteries)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every 2 secondsOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

Dimension, D x W x H (mm) 369 x 190 x 688 442 x 190 x 688Net Weight (kgs) 54 66

Long-run Model

Dimension, D x W x H (mm) 369 x 190 x 318 442 x 190 x 318Net Weight (kgs) 13 16

ENVIRONMENTOperating Humidity 20-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 50dB @1Meter Less than 58dB @1MeterMANAGEMENTSmart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.**When using batteries from 16-19, the unit will de-rate according to below formula: P=Prating x N/20.***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

Page 30: PROLINK POWER BACKUP SOLUTION

29

Full Specifications

ONLINE UPS

MODEL PRO806-QS/QL PRO810-QS/QLPHASE 1 phase in / 1 phase outCAPACITY 6000 VA / 6000 W 10000 VA / 10000 WINPUTNominal Voltage 208/220/230/240 VAC

Voltage Range110-300 VAC @ 0 ~60% load

140-300 VAC @ 60 ~ 80% load176-300 VAC @ 80 ~ 100% load

Frequency Range 46~54 Hz or 56~64 Hz Phase Single phase with groundPower Factor ≧ 0.99 @ full loadTHDi <4% @100% Load ; <6% @50% Load OUTPUTOutput Voltage 208/220/230/240 VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54 Hz or 56~64 Hz Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)Harmonic Distortion ≦1 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure Sinewave

OverloadAC Mode 100%~110% 10min ; 110%~130%: 1min ; >130% : 1secBattery Mode 100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec

EFFICIENCYAC Mode 94%Battery Mode 91%BATTERY

Standard Model

Battery Type 12 V / 7 Ah 12 V / 9 AhNumbers 16Typical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1.0 ACharging Voltage 218.4 VDC ± 1%

Long-run Model

Battery Type Depending on applicationsNumbers 16-20**Charging Current (max.) 4.0 ACharging Voltage 218.4 VDC ± 1% (Based on 16 pcs batteries)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every 2 secondsOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

Dimension, D x W x H (mm) 369 x 190 x 688 442 x 190 x 688Net Weight (kgs) 54 66

Long-run Model

Dimension, D x W x H (mm) 369 x 190 x 318 442 x 190 x 318Net Weight (kgs) 13 16

ENVIRONMENTOperating Humidity 20-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 50dB @1Meter Less than 58dB @1MeterMANAGEMENTSmart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.**When using batteries from 16-19, the unit will de-rate according to below formula: P=Prating x N/20.***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

Master II Series (1P/1P)-Rack/Tower

ONLINE UPS

PROLiNK Master II Series (1P/1P) Rack / Tower Type is a true online double conversion single phase UPS system which is designed to deliver clean and high quality electrical power to fully protect critical devices in wide range of applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

UPS is equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

The front panel LCD display comes with rotation feature which to be used for both rack and tower types. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

PROLiNK Master II series (1P/1P) Rack /Tower p.f 0.9 Type is available in capacities ranging from 1KVA to 3KVA.

In addition, Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO800-ERS/ERL SERIES 1-3KVA

• True double-conversion online UPS

• Output power factor 0.9

• User-friendly and easy-shift LCD display

• Rack/Tower design

• Programmable power management outlets

• 50/60 Hz frequency converter mode

• ECO and advanced ECO mode for energy saving

• Emergency Power Off Function (EPO)

• Hot-swappable battery design

StoragePLCS

EmergencyAlarm Devices

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

19” RackMount

Page 31: PROLINK POWER BACKUP SOLUTION

30

ONLINE UPS

Rear Panel

1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)

7. USB communication port8. RS-232 communication port9. Intelligent slot10. External battery connector 11. Cooling Fan

1-3KVA

7

8 4

6 9510 11 1 3

2PRO803-ERS/ERL

7

8 4

6 9 510 11 1 3

2PRO802-ERS/ERL

710 11

8

6 9 5 1 3

2PRO801-ERS/ERLPRO8015-ERS/ERL

Page 32: PROLINK POWER BACKUP SOLUTION

31

ONLINE UPS

Rear Panel

1. Programmable outlets: connect to non-critical loads2. Output receptacles: connect to mission-critical loads3. AC input4. Input circuit breaker5. Network/Fax/Modem surge protection6. Emergency power off function connector (EPO)

7. USB communication port8. RS-232 communication port9. Intelligent slot10. External battery connector 11. Cooling Fan

1-3KVA

7

8 4

6 9510 11 1 3

2PRO803-ERS/ERL

7

8 4

6 9 510 11 1 3

2PRO802-ERS/ERL

710 11

8

6 9 5 1 3

2PRO801-ERS/ERLPRO8015-ERS/ERL

Full Specifications

ONLINE UPS

MODEL PRO801-ERS/ERL PRO8015-ERS/ERL PRO802-ERS/ERL PRO803-ERS/ERL

PHASE Single phase with ground

CAPACITYVA 1000 VA 1500 VA 2000 VA 3000 VA

W 900 W 1350 W 1800 W 2700 W

INPUTNominal Voltage 100*/110*/115*/120 /127 VAC or 200/208/220/230/240 VAC

Voltage Range 55-150 VAC ± 5% or 110-300 VAC ± 5%

Frequency Range 40Hz ~ 70Hz

Power Factor ≧ 0.99 @ Nominal Voltage (100% Load)

OUTPUTOutput Voltage 100*/110*/115*/120/127 VAC or 200/208/220/230/240 VAC

AC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.5% or 60Hz ± 0.5%

Current Crest Ratio 5:1 (max.)

Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear load)

Transfer TimeAC Mode to Battery Mode Zero

Inverter to Bypass 4 ms (Typical)

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCYAC Mode 87% 88% 88% 89%

ECO Mode 94% 95% 95% 97%

Battery Mode 85% 86% 86% 87%

BATTERY

Battery Type 12 V / 9 Ah Depending on the capacity of external batteries

12 V / 9 Ah Depending on the capacity of external batteries

12 V / 9 Ah Depending on the capacity of external batteries

12 V / 9 Ah Depending on the capacity of external batteries

Numbers 2 3 4 6

Typical Recharge Time4 hours

recover to 90% capacity

4 hours recover to 90%

capacity

4 hours recover to 90%

capacity

4 hours recover to 90%

capacityCharging Current (max.) 1.0 A 1A / 2A / 4A / 8A 1.0 A 1A / 2A / 4A / 8A 1.0 A 1A / 2A / 4A / 8A 1.0 A 1A / 2A / 4A / 8A

Charging Voltage 27.4 VDC ± 1% 41.1 VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1%

INDICATORSLCD Display Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator

ALARMBattery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continously sounding

PHYSICALDimension, D x W x H (mm) 410 x 438 x 88 [2U] 510 x 438 x 88 [2U] 510 x 438 x 88 [2U] 630 x 438 x 88 [2U] Net Weight (kgs) 12.9 8.6 17.6 10.7 20.6 11.3 28 13.8

ENVIRONMENTHumidity 20-90 % RH @ 0- 40°C (Non-condensing)

Noise Level Less than 50dBA @ 1 Meter

MANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux, Unix, and MAC

Optional SNMP Power management from SNMP manager and web browser**Derate capacity to 95% when the output voltage is adjusted to 115VAC, derate capacity to 90% when the output voltage is adjusted to 110VAC and derate capacity to 80% when the output voltage is adjusted to 100VAC/200VAC/208VAC.

Page 33: PROLINK POWER BACKUP SOLUTION

32

Master II Series (1P/1P)-Rack/Tower

ONLINE UPS

PROLiNK Master II Series (1P/1P) Rack / Tower Type is a new UPS series with output power factor 1.0. The system design is based on a true online double-conversion technology to optimize system reliability and to deliver clean and high quality electrical power to wide range of critical applications. High input power factor correction in the system improves the efficiency and reduces overall losses.

DSP control technology is implemented for the UPS ratings 6KVA and above to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time. Hot swappable battery design is implemented for the UPS ratings from 1KVA to 3KVA.

The front panel LCD display comes with rotation feature which to be used for both rack and tower types. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

PROLiNK Master II series (1P/1P) Rack / Tower- p.f 1.0 Type is available in capacities ranging from 1KVA to 10KVA. Higher charging current is available for 1KVA~3KVA models and it can be set via LCD display.

In addition, Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO800-QRS/QRL SERIES 1-10KVA

Only available for 1-3KVA

• Emergency power off function (EPO)• Generator compatible • SNMP/USB/RS-232 communications• Adjustable battery numbers• Optional N+X parallel redundancy• Low input THDi to reduce power system pollution• Adjustable charging current via LCD panel• Smart battery charger design to optimize battery performance

• True double-conversion • DSP technology guarantees high performance• Output power factor 1 • Wide input voltage range (110-300 VAC)• Active input power factor correction 0.99• 50Hz/60Hz frequency converter mode• Programmable power management outlets• Hot swappable battery design• ECO mode energy saving

StoragePLCS

EmergencyAlarm Devices

Work-Stations ServersLocal AreaNetwork (LAN)

Small ComputerNetwork

19” RackMount

Page 34: PROLINK POWER BACKUP SOLUTION

33

ONLINE UPS

Rear Panel

2

1 12 10 8 3

5 6 7 13 4

9 11

PRO806-QRS/QRLPRO810-QRS/QRL

1-3KVA

1. Programmable outlets: connect to non-critical loads. 2. Output receptacles: connect to mission-critical loads.3. AC input4. Network/Fax/Modem surge protection5. USB communication port

6. RS-232 communication port7. Intelligent slot8. Emergency power off function connector (EPO)9. External battery connection 10. Cooling fan

6-10KVA1. Share current port (only available for parallel configuration)2. Parallel port (only available for parallel configuration)3. External battery connector 4. Intelligent slot5. RS-232 communication port 6. USB communication port 7. Emergency power off function connector (EPO connector)

8. Input circuit breaker9. Output terminals10. Ground11. Input terminals12. Cooling Fan 13. External maintenance bypass switch port

PRO801-QRS / PRO8015-QRS26

4 510 8 7 9 31

PRO802-QRS 26

4 510 8 7 9 31

PRO803-QRS 68

410 57 9

2 2

1 3

Page 35: PROLINK POWER BACKUP SOLUTION

34

ONLINE UPS

Full Specifications

MODEL PRO801-QRS PRO8015-QRS PRO802-QRS PRO803-QRSPHASE Single phase with groundCAPACITY* 1000 VA / 1000 W 1500 VA / 1500 W 2000 VA / 2000 W 3000 VA / 3000 WINPUTNominal Voltage 100/110/115/120/127 VAC or 200/208/220/230/240 VAC

Voltage Range 55-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load80-150 VAC ± 5% or 160-300 VAC ± 5% @ 100% load

Frequency Range 40 Hz ~ 70 HzPower Factor ≧ 0.99 @ nominal voltage (100% load)Harmonic Distortion(THDi) ≦ 5% @ nominal input voltageOUTPUTOutput Voltage 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 57 ~ 63 Hz or 47 ~ 53 HzFrequency Range (Batt. Mode) 60Hz ± 0.1Hz or 50 Hz ± 0.1HzCurrent Crest Ratio 3:1 (max.)Harmonic Distortion ≦2 % THD (Linear Load) ; ≦ 4 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass 4 ms (Typical)

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode ≧89% @ full charged battery ≧91% @ full charged batteryECO Mode ≧96% @ full charged batteryBattery Mode ≧88% ≧90%BATTERYBattery Type 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 7 Ah 12 V / 9 AhNumbers 2 3 3 4 6 6Typical Recharge Time 3 hours recover to 95% capacity for internal battery@ 2A charging current

Charging Current 100/110/115/120 /127 VAC models: default 2A, max. 8A adjustable200/208/220/230/240 VAC models: default 2A, max. 12A adjustable Default: 2A, Max: 8A adjustable

Charging Voltage 27.4 VDC ± 1% 41.1 VDC ± 1% 41.1 VDC ± 1% 54.8 VDC ±1% 82.1 VDC ±1% 82.1 VDC ±1%INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 5 secondsLow Battery Sounding every 2 secondsOverload Sounding every secondFault Continuously soundingPHYSICALDimension, D x W x H(mm) 410 x 438 x 88 410 x 438 x 88 510 x 438 x 88 630 x 438 x 88 630 x 438 x 88Net Weight (without battery) (kgs) 6.6 7.8 8.1 9.4 10.6 12.4Net Weight (w/built-int battery) (kgs) 11.6 14.1 15.5 19.5 23.3 27.5ENVIRONMENTHumidity 20-90 % RH @ 0- 40°C (non-condensing)Noise Level Less than 50dB @ 1 MeterMANAGEMENTSmart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browserSTANDARDEMC/safety (EMC 1-1.5K: EN62040-2 C1, 2K-3K EN62040-2 C2) for CE models*Derate capacity to 80% when the output voltage is adjusted to 100VAC/200VAC/208VAC.

Page 36: PROLINK POWER BACKUP SOLUTION

35

Full Specifications

ONLINE UPS

MODEL PRO806-QRS/QRL PRO810-QRS/QRLPHASE 1 phase in / 1 phase outCAPACITY* 6000 VA / 6000 W 10000 VA / 10000 WINPUTNominal Voltage 208/220/230/240 VAC

Voltage Range110~300VAC @(0~60%) Load

140~300VAC @ ( 60~80% ) Load176~300VAC @(80~100%) Load

Frequency Range 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60HzPower Factor ≧ 0.99 @ full loadTHDi < 4% @100% Load, < 6% @50% Load OUTPUTOutput Voltage 104/110/115/120VAC 104/110/115/120VACAC Voltage Regulation ± 1%Frequency Range (Synchronized Range) 46~54 Hz ◎ 50Hz / 56~64 Hz ◎ 60HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)Harmonic Distortion ≦1.5 % THD (Linear Load), ≦7 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure Sinewave

OverloadAC Mode 100%~110%: 10min、110%~130%: 1min、>130% : 1secBattery Mode 100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec

EFFICIENCYLine Mode 89%Battery Mode 86%BATTERY

Standard Model

Battery Type 12 V / 7 AH 12 V / 9 AHNumbers 16 16Typical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1.0 ACharging Voltage 218.4 VDC ± 1% 218.4 VDC ± 1%

Long-run Model

Battery Type Depending on applicationsNumbers 16-20**Charging Current (max.) 4.0 ACharging Voltage (13.65VDC x battery number) ± 1%

INDICATORSLCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

Dimension, D x W x H (mm)UPS Unit: 600x438x88 [2U]

Battery Pack: 695x438x88 [2U]ISO Pack: 600 x 438 x 88 [2U]

UPS Unit: 600x438x88 [2U]Battery Pack: 695x438x88 [2U]ISO Pack: 686 x 438 x 133 [3U]

Net Weight (kgs) UPS Unit: 15Battery Pack: 48 ; ISO Pack: 61

UPS Unit: 18Battery Pack: 48 ; ISO Pack: 90

Long-run Model

Dimension, D x W x H (mm) UPS Unit: 600 x 438 x 88 [2U]ISO Pack: 600 x 438 x 88 [2U]

UPS Unit: 600 x 438 x 88 [2U]ISO Pack: 686 x 438 x 133 [3U]

Net Weight (kgs) UPS Unit: 15 ; ISO Pack: 61 UPS Unit: 18 ; ISO Pack: 90ENVIRONMENTOperating Humidity 20-90 % RH @ 0- 40°C (non-condensing)Noise Level Less than 55dB @ 1 Meter Less than 58dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

* Derate capacity to 60% of capacity in CVCF mode.**When using batteries from 16-19, the unit will de-rate according to below formula: P=Prating x N/20.If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

Page 37: PROLINK POWER BACKUP SOLUTION

36

Master II Series (3P/3P)-Tower

ONLINE UPS

PRO83300-FS/FL SERIES 30-200KVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

PROLiNK Master II Series (3P/3P) Tower Type is a three-phase output UPS system that employs a true online double-conversion technology. Double conversion between input/output, battery and bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. High input power factor correction in the system improves the efficiency and reduces overall losses.

DSP control technology is implemented for the UPS system to improve performance and real time harmonic cancellation. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

PROLiNK Master II Series (3P/3P) is available in capacities ranging from 30KVA to 200KVA. Maintenance bypass is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option and is limited up to 3 units for (30KVA to 80KVA) and 2 units for (100KVA to 200KVA).

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. For 100KVA and above models, charging current can be adjusted via LCD. Optional 10” touch LCD panel is available for the system.

Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

• True double conversion• DSP technology guarantees high reliability• Output power factor 0.9• Active power factor correction in all phases• 50Hz/60Hz frequency converter mode• ECO mode operation for energy saving • Emergency power off function (EPO)• Optional parallel operation• Smart battery charger design to optimize battery performance• Maintenance bypass available• Adjustable battery design • Adjustable charging current only available for 100K and up models • Optional 10" touch colored LCD only available for 100K and up models

Page 38: PROLINK POWER BACKUP SOLUTION

37

ONLINE UPS

Full SpecificationsMODEL PRO83330-FS/FL PRO83340-FS/FL PRO83360-FL PRO83380-FL PRO833100-FL PRO833120-FL PRO833160-FL PRO833200-FL

PHASE 3-phase in / 3-phase out

CAPACITY 30KVA / 27KW 40KVA / 36KW 60KVA / 54KW 80KVA / 72KW 100KVA / 90KW 120KVA / 108KW 160KVA / 144KW 200KVA / 180KW

INPUT

Nominal Voltage 3 x 400 VAC (3Ph+N)

Voltage Range 190-520 VAC (3-phase) @ 50% load ; 305-478 VAC (3-phase) @ 100% load

208-478 VAC (3-phase) @ 70% load305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz 40~70Hz

Power Factor ≧ 0.99 @ 100% Load

OUTPUT

Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)

AC Voltage Regulation (Batt. Mode) ± 1%

Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

Current Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2 % THD (Linear Load) ; ≦4 % THD (Non-linear Load)

≦2 % THD (Linear Load) ; ≦4 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode Zero

Inverter to Bypass Zero

Waveform (Batt. Mode) Pure Sine wave

OverloadAC Mode 100-110% for 10 min, 110-130% for 1 min,

>130% for 1 second105-110% for 1 hr, 111-125% for 10 min, 126-150% for 1 min,

>150% for 200ms

Battery Mode 100-110% for 30 seconds, 110-130% for 10 seconds, >130% for 1 second

105-110% for 1 hr, 111-125% for 10 min, 126-150% for 1 min, >150% for 200ms

Parallel Capacity up to 3 units in parallel up to 2 units in parallel

EFFICIENCY

AC Mode 94.5% 94.5%

ECO Mode 98.0% 98.0%

Battery Mode 94.5%

BATTERY

Standard Model

Battery Type 12 V / 7 Ah 12 V / 9 Ah

N/A

Numbers (16+16)pcs x 2 strings

(16+16)pcs x 2 strings

Typical Recharge Time 9 hours recover to 90% capacity

Charging Current (max.) 2A

Charging Voltage ± 218 VDC

Long-run Model

Battery Type Depending on the capacity of external batteries

Numbers 32~40 pcs (Adjustable)

Charging Current (max.) 4A 8A 24A 32A 40A 48A

Charging Voltage +/- 13.65V x N (N=16~20) +/-13.7V*N (N = 16~20)

INDICATORS

LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions 5.7” monochrome LCD or 10” Touch Type color LCD

ALARM

Battery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continously sounding

PHYSICAL

Standard Model

Dimension, D x W x H (mm) 815 x 300 x 1000N/A

Net Weight (kgs) 205 230

Long-run Model

Dimension, D x W x H (mm) 815 x 300 x 1000 790 x 360 x 1010 940 x 567 x 1000 1040 x 567 x 1442Net Weight (kgs) 60 61 108 113 194 229 301 335

ENVIRONMENT

Operation Temperture 0-40°C

Operation Humidity < 95% and non-condersing

Noise Level Less than 70dB @ 1 Meter Less than 70dB @ 1 Meter Less than 73dB @ 1 Meter

MANAGEMENT

Smart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MAC

Optional SNMP Power management from SNMP manager and web browser

*If output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%.

Page 39: PROLINK POWER BACKUP SOLUTION

38

Master II+ Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Master II+ (3P/1P) Series are UPS systems are designed to deliver clean and high quality electrical power to fully protect wide range of critical applications such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. In order to have improved performance and real time harmonic cancellation, DSP control technology is implemented for all Master II+ series. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Maintenance bypass is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option.

Master II+ Tower Series (3P/1P) P.F 0.9 is available in capacities ranging from 10KVA to 30KVA. Programmable power outlet feature is implemented in the system so that during power failure, this enables users to extend battery time to critical devices by shutting down the non-critical devices.

PRO83100-ES/EL SERIES 10-30KVA

• True double-conversion

• DSP technology guarantees high performance

• Output power factor 0.9

• Wide input voltage range (110-300 VAC)

• Active power factor correction in all phases

• Built-in phase auto adapt function simplifies

wire installation

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

• Programmable power management outlets

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for

optimized battery performance

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

Page 40: PROLINK POWER BACKUP SOLUTION

39

Master II+ Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Master II+ (3P/1P) Series are UPS systems are designed to deliver clean and high quality electrical power to fully protect wide range of critical applications such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. In order to have improved performance and real time harmonic cancellation, DSP control technology is implemented for all Master II+ series. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Maintenance bypass is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option.

Master II+ Tower Series (3P/1P) P.F 0.9 is available in capacities ranging from 10KVA to 30KVA. Programmable power outlet feature is implemented in the system so that during power failure, this enables users to extend battery time to critical devices by shutting down the non-critical devices.

PRO83100-ES/EL SERIES 10-30KVA

• True double-conversion

• DSP technology guarantees high performance

• Output power factor 0.9

• Wide input voltage range (110-300 VAC)

• Active power factor correction in all phases

• Built-in phase auto adapt function simplifies

wire installation

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

• Programmable power management outlets

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for

optimized battery performance

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Maintenance bypass switch

8. Line input circuit breaker9. Output circuit breaker for receptacles 10. Output receptacles: connect to mission-critical loads11. Input/Output terminal 12. External battery connector/terminal (only available for Long-run model) 13. Input/Output/Battery terminal14. Cooling Fan

10-30KVA

PRO83110-ES/EL

1 2 3 4

6

12

8

11

7

9

10

5

14

14

PRO83115-EL/PRO83120-EL

6

8

1414

13

7

1 2 3 4 5

PRO83115-ES/PRO83120-ES

6

8

11

7

1 2 3 4 5

1414

PRO83130-EL

6

8

13

7

1 2 3 4 5

1414

PRO83130-ES

6

8

11

7

1 2 3 4 5

1414

Page 41: PROLINK POWER BACKUP SOLUTION

40

Full Specifications

ONLINE UPS

MODEL PRO83110-ES/EL PRO83115-ES/EL PRO83120-ES/EL PRO83130-ES/ELPHASE 3-phase in / 1-phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 W 30000 VA / 27000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)Voltage Range 190-520 VAC (3-phase) @ 50% load ; 305-478 VAC (3-phase) @ 100% load Frequency Range 46~54Hz or 56~64HzPower Factor ≧ 0.99 @ 100% LoadTHDi < 6% @ 100% loadOUTPUTOutput Voltage 208/220/230/240VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2 % THD (Line ar Load)≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 91.5% 91.8% 91.8% 92.1%ECO Mode 97% 97% 97% 97%Battery Mode 87% 88% 88% 89%BATTERY

Standard Model

Battery Type 12 V / 9 Ah

Numbers 20 pcs (18 - 20 pcs adjustable)* 20 pcs (18 - 20 pcs adjustable)* x 2 strings 20pcs(18-20pcs adjustable)*x3 strings

Typical Recharge Time 9 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current (max.) 1A 2A 2A 4ACharging Voltage 273 VDC ± 1% (Based on 20pcs batteries)

Long-run Model

Battery TypeDepending on applications

NumbersCharging Current (max.) 4A 8A 8A 12ACharging Voltage 273 VDC ± 1% (Based on 20pcs batteries)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continously soundingPHYSICALStandard Model

Dimension, D x W x H (mm) 592 x 250 x 576 815 x 250 x 826 815 x 300 x 1000Net Weight (kgs) 83 164 164 234

Long-run Model

Dimension, D x W x H (mm) 592 x 250 x 576 592 x 250 x 576 592 x 250 x 576 815 x 250 x 826Net Weight (kgs) 28 40 40 64

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 58dB @ 1 Meter Less than 60dB @1 Meter Less than 65dB @1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

* L means long-run model.**When using internal batteries from 18-19, the unit will de-rate according to below formula: P = PRating x N/20.**Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.

Page 42: PROLINK POWER BACKUP SOLUTION

41

Full Specifications

ONLINE UPS

MODEL PRO83110-ES/EL PRO83115-ES/EL PRO83120-ES/EL PRO83130-ES/ELPHASE 3-phase in / 1-phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 W 30000 VA / 27000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)Voltage Range 190-520 VAC (3-phase) @ 50% load ; 305-478 VAC (3-phase) @ 100% load Frequency Range 46~54Hz or 56~64HzPower Factor ≧ 0.99 @ 100% LoadTHDi < 6% @ 100% loadOUTPUTOutput Voltage 208/220/230/240VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2 % THD (Line ar Load)≦5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 91.5% 91.8% 91.8% 92.1%ECO Mode 97% 97% 97% 97%Battery Mode 87% 88% 88% 89%BATTERY

Standard Model

Battery Type 12 V / 9 Ah

Numbers 20 pcs (18 - 20 pcs adjustable)* 20 pcs (18 - 20 pcs adjustable)* x 2 strings 20pcs(18-20pcs adjustable)*x3 strings

Typical Recharge Time 9 hours recover to 90% capacity 9 hours recover to 90% capacityCharging Current (max.) 1A 2A 2A 4ACharging Voltage 273 VDC ± 1% (Based on 20pcs batteries)

Long-run Model

Battery TypeDepending on applications

NumbersCharging Current (max.) 4A 8A 8A 12ACharging Voltage 273 VDC ± 1% (Based on 20pcs batteries)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continously soundingPHYSICALStandard Model

Dimension, D x W x H (mm) 592 x 250 x 576 815 x 250 x 826 815 x 300 x 1000Net Weight (kgs) 83 164 164 234

Long-run Model

Dimension, D x W x H (mm) 592 x 250 x 576 592 x 250 x 576 592 x 250 x 576 815 x 250 x 826Net Weight (kgs) 28 40 40 64

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 58dB @ 1 Meter Less than 60dB @1 Meter Less than 65dB @1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

* L means long-run model.**When using internal batteries from 18-19, the unit will de-rate according to below formula: P = PRating x N/20.**Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.

Master II+ Series (3P/1P)-Rack

ONLINE UPS

PRO83100-ERS/ERL SERIES 10-20KVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

19” RackMount

• True double-conversion

• DSP technology guarantees high performance

• Output power factor 0.9

• Wide input voltage range (110-300 VAC)

• Active power factor correction in all phases

• Built-in phase auto adapt function simplifies

wire installation

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for

optimized battery performance

• Adjustable battery numbers

• Optional N+X parallel redundancy

PROLiNK Master II+ (3P/1P) UPS systems are designed to deliver clean and high quality electrical power to fully protect wide range of critical applications such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. In order to have improved performance and real time harmonic cancellation, DSP control technology is implemented for all Master II+ series. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

External maintenance bypass switch port is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option.

Master II+ Rack Series (3P/1P) P.F 0.9 is available in capacities ranging from 10KVA to 20KVA.

Page 43: PROLINK POWER BACKUP SOLUTION

42

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Line input circuit breaker

8. Utility input terminal9. Output terminal: connect to mission-critical loads10. External battery connector/terminal (only available for Long-run model) 11. External maintenance bypass switch port12. Cooling Fan 13. Grounding terminal

10-20KVA

1

9

10

13

2

3

4

5

6

7

11 12

12

8

PRO83115-ERS/ERLPRO83120-ERS/ERL

1

210

11

6

3

5 124

9 8 7 PRO83110-ERS/ERL

Page 44: PROLINK POWER BACKUP SOLUTION

43

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Line input circuit breaker

8. Utility input terminal9. Output terminal: connect to mission-critical loads10. External battery connector/terminal (only available for Long-run model) 11. External maintenance bypass switch port12. Cooling Fan 13. Grounding terminal

10-20KVA

1

9

10

13

2

3

4

5

6

7

11 12

12

8

PRO83115-ERS/ERLPRO83120-ERS/ERL

1

210

11

6

3

5 124

9 8 7 PRO83110-ERS/ERL

Full Specifications

ONLINE UPS

MODEL PRO83110-ERS/ERL PRO83115-ERS/ERL PRO83120-ERS/ERLPHASE 3-phase in / 1-phase outCAPACITY 10000 VA/9000 W 15000 VA/13500 W 20000 VA / 18000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% LoadTHDi < 6% @ 100% LoadOUTPUTOutput Voltage 208/220/230/240VACAC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1

Harmonic Distortion ≦ 2 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90.5% 91%ECO Mode 96% 96%Battery Mode 87% 88%BATTERY

Standard Model

Battery Type 12 V / 9 AhNumbers 20 (18 - 20 pcs* adjustable) 20 pcs x 2 strings (18 - 20 pcs* adjustable)Typical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1A 2ACharging Voltage 273 VDC ± 1% (based on battery numbers at 20 pcs)

Long-run Model

Battery TypeDepending on the capacity of external batteries

NumbersCharging Current (max.) 4ACharging Voltage 273 VDC ± 1% (based on battery numbers at 20 pcs)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continously soundingPHYSICAL

Standard Model

Dimension, D x W x H (mm) UPS unit:668 x 438 x 133 [3U]Battery pack: 580 x 438 x 133 [3U]

UPS unit:668 x 438 x 266 [6U] Battery pack: 580 x 438 x 133 [3U] x 2PCS

Net Weight (kgs) UPS unit: 22Battery pack: 63

UPS unit: 45Battery pack: 63 x 2 pcs

Long-run Model

Dimension, D x W x H (mm) 668 x 438 x 133 [3U] 668 x 438 x 266 [6U]Net Weight (kgs) 22 45

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 60dB @ 1 Meter Less than 65dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.

Page 45: PROLINK POWER BACKUP SOLUTION

44

Master II+ Series (3P/3P)-Tower

ONLINE UPS

PROLiNK Master II+ (3P/3P) Series are UPS systems are designed to deliver clean and high quality electrical power to fully protect wide range of critical applications such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. In order to have improved performance and real time harmonic cancellation, DSP control technology is implemented for all Master II+ series. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Maintenance bypass is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option.

Master II+ Tower Value Series (3P/3P) P.F 0.9 is available in capacities ranging from 10KVA to 20KVA. These units can accept dual-mains input to the system.

PRO83300-VES/VEL SERIES 10-20KVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

• True double-conversion

• DSP technology guarantees high performance

• Output power factor 0.9

• Active power factor correction in all phases

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving

• Customized dual-mains inputs

• Emergency power off function (EPO)

• Generator compatible

• 3-stage extendable charging design for

optimized battery performance

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

• Optional isolation transformer offers

full isolation and complete common mode

noise rejection

Page 46: PROLINK POWER BACKUP SOLUTION

45

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. External battery connector (Only available for long-run model)

8. Line Input circuit breaker 9. Input/Output terminal10. Maintenance bypass switch11. Cooling fan

10-20KVA

PRO83310-VEL

6

4321

810

97

5

1111

PRO83315-VEL/PRO83320-VEL

6

4321

810

97

5

1111

PRO83310-VES

6

4321

810

9 7

5

1111

6

810

9

7

4321 5

PRO83315-VES/PRO83320-VES

1111

Page 47: PROLINK POWER BACKUP SOLUTION

46

Full Specifications

ONLINE UPS

MODEL PRO83310-VES/VEL PRO83315-VES/VEL PRO83320-VES/VELPHASE 3 phase in / 3 phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)

Voltage Range 190-520 VAC (3-phase) @ 50% load305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% loadOUTPUTOutput Voltage 3 x 400 VAC (3Ph+N) AC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90.5% 91.5% 91.5%ECO Mode 96.0%Battery Mode 87.0% 88.0% 88.0%BATTERY

Standard Model

Battery Type 12 V / 9 AhNumbers 16 pcs 16 pcs x 2 stringsTypical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1 ACharging Voltage 218.4 VDC ± 1%

Long-run Model

Battery Type Depending on the capacity of external batteriesNumbers 20 PCS (Default, 16-20 pcs adjustable)Charging Current (max.) 4A 4A 4ACharging Voltage 273 VDC ± 1% (Based on 20 pcs batteries)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

Dimension, DxWxH(mm) 592 x 250 x 82696 146

Long-run Model

Dimension, DxWxH(mm) 592 x 250 x 576Net Weight (kgs) 32 35

ENVIRONMENTHumidity 0-95 % RH @ 0- 40°C (non-condensing)Noise Level Less than 60dB@1Meter Less than 65dB@1MeterMANAGEMENTSmart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and MACOptional SNMP Power management from SNMP manager and web browser* L means long-run model **When using batteries from 16-19, the unit will de-rate according to below formula: P=Prating X N/20

Net Weight (kgs)

Page 48: PROLINK POWER BACKUP SOLUTION

47

Full Specifications

ONLINE UPS

MODEL PRO83310-VES/VEL PRO83315-VES/VEL PRO83320-VES/VELPHASE 3 phase in / 3 phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)

Voltage Range 190-520 VAC (3-phase) @ 50% load305-478 VAC (3-phase) @ 100% load

Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% loadOUTPUTOutput Voltage 3 x 400 VAC (3Ph+N) AC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90.5% 91.5% 91.5%ECO Mode 96.0%Battery Mode 87.0% 88.0% 88.0%BATTERY

Standard Model

Battery Type 12 V / 9 AhNumbers 16 pcs 16 pcs x 2 stringsTypical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1 ACharging Voltage 218.4 VDC ± 1%

Long-run Model

Battery Type Depending on the capacity of external batteriesNumbers 20 PCS (Default, 16-20 pcs adjustable)Charging Current (max.) 4A 4A 4ACharging Voltage 273 VDC ± 1% (Based on 20 pcs batteries)

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continuously soundingPHYSICAL

Standard Model

Dimension, DxWxH(mm) 592 x 250 x 82696 146

Long-run Model

Dimension, DxWxH(mm) 592 x 250 x 576Net Weight (kgs) 32 35

ENVIRONMENTHumidity 0-95 % RH @ 0- 40°C (non-condensing)Noise Level Less than 60dB@1Meter Less than 65dB@1MeterMANAGEMENTSmart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and MACOptional SNMP Power management from SNMP manager and web browser* L means long-run model **When using batteries from 16-19, the unit will de-rate according to below formula: P=Prating X N/20

Net Weight (kgs)

Master II+ Series (3P/3P)-Tower

ONLINE UPS

PROLiNK Master II+ (3P/3P) Series are UPS systems are designed to deliver clean and high quality electrical power to fully protect wide range of critical applications such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. In order to have improved performance and real time harmonic cancellation, DSP control technology is implemented for all Master II+ series. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Maintenance bypass is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option.

Master II+ Tower Series (3P/3P) P.F 0.9 is available in capacities ranging from 10KVA to 30KVA. UPS ratings from 10KVA to 20KVA accept dual-mains input.

PRO83300-ES/EL SERIES 10-30KVA

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

• True double-conversion

• DSP technology guarantees high performance

• Output power factor 0.9

• Active power factor correction in all phases

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving (ECO)

• Accepts dual-mains inputs (Only for

10K/15K/20K models)

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for

optimized battery performance

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

Page 49: PROLINK POWER BACKUP SOLUTION

48

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Cooling fan

8. External battery connector (Only available for long-run model) 9. Bypass Input Circuit Breaker (Only available for dual input unit)10. Input/Output terminal 11. Line Input circuit breaker 12. Maintenance bypass switch

10-30KVA

PRO83330-ES

1 2 3 4

6

812

11

10

5

77

PRO83330-EL

1 2 3 4

6

812

11

10

5

77

PRO83310-ES/ELPRO83320-ES/EL

1 2 3 4

6

8

9

12

11

10

5

77

Page 50: PROLINK POWER BACKUP SOLUTION

49

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (only available for parallel configuration)5. Parallel port (only available for parallel configuration)6. Intelligent slot7. Cooling fan

8. External battery connector (Only available for long-run model) 9. Bypass Input Circuit Breaker (Only available for dual input unit)10. Input/Output terminal 11. Line Input circuit breaker 12. Maintenance bypass switch

10-30KVA

PRO83330-ES

1 2 3 4

6

812

11

10

5

77

PRO83330-EL

1 2 3 4

6

812

11

10

5

77

PRO83310-ES/ELPRO83320-ES/EL

1 2 3 4

6

8

9

12

11

10

5

77

Full Specifications

ONLINE UPS

MODEL PRO83310-ES/EL PRO83315-ES/EL PRO83320-ES/EL PRO83330-ES/ELPHASE 3-phase in / 3-phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 W 30000 VA / 27000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N) Input Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% loadFrequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% LoadOUTPUTOutput Voltage 3 x 400 VAC (3Ph+N) AC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90.5% 91.5% 91.5% 92.1%ECO Mode 96%Battery Mode 87% 88% 88% 89%BATTERY

Standard Model

Battery Type 12 V / 9 AhNumbers 20 pcs (18 - 20 adjustable)* 20 pcs (18 - 20 adjustable)*x 2 strings 20pcs (18-20 adjustable)* x 3 stringsTypical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1A 2A 2A 4ACharging Voltage 273 VDC ± 1%

Long-run Model

Battery TypeDepending on the capacity of external batteries

NumbersCharging Current (max.) 4A 4A 4A 12ACharging Voltage 273 VDC ± 1%

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault ALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continously soundingPHYSICALStandard Model

Dimension, D x W x H (mm) 815 x 250 x 826 815 x 250 x 826 815 x 250 x 826 815 x 300 x 1000Net Weight (kgs) 109 164 164 233.5

Long-run Model

Dimension, D x W x H (mm) 592 x 250 x 826 592 x 250 x 826 592 x 250 x 826 815 x 250 x 826Net Weight (kgs) 38 40 40 64

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 60dB @ 1 Meter Less than 65dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.

Page 51: PROLINK POWER BACKUP SOLUTION

50

Master II+ Series (3P/3P)-Rack

ONLINE UPS

PRO83300-ERS/ERL SERIES 10-20KVA

• True double-conversion

• DSP technology guarantees high performance

• Output power factor 0.9

• Wide input voltage range (110-300 VAC)

• Active power factor correction in all phases

• 50Hz/60Hz frequency converter mode

• Eco mode operation for energy saving (ECO)

• Accepts dual power inputs

• Emergency power off function (EPO)

• Generator compatible

• SNMP+USB+RS-232 multiple communications

• 3-stage extendable charging design for

optimized battery performance

• Adjustable battery numbers

• Maintenance bypass available

• Optional N+X parallel redundancy

• Optional isolation transformer offers full

isolation and complete common mode noise

PROLiNK Master II+ (3P/3P) Series are UPS systems are designed to deliver clean and high quality electrical power to fully protect wide range of critical applications such as sensitive networks, small computer centres, servers, medical equipment, telecom applications as well as industrial applications.

High input power factor correction in the system improves the efficiency and reduces overall losses. In order to have improved performance and real time harmonic cancellation, DSP control technology is implemented for all Master II+ series. UPS is also equipped with 3-stage smart charging design to optimize battery performance. This feature extends the useful service life of battery and optimizes battery recharge time.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Maintenance bypass is available for the loads which uptime is critical so that bypass allows seamless transfer of electrical loads from UPS power to mains. Parallel Redundant configuration is available as an option.

Master II+ Rack Series (3P/3P) P.F 0.9 is available in capacities ranging from 10KVA to 20KVA.

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

19” RackMount

Page 52: PROLINK POWER BACKUP SOLUTION

51

ONLINE UPS

Rear Panel

1. RS-232 communication port 2. USB communication port 3. Emergency power off function connector (EPO connector)4. Share current port (Only available for parallel configuration)5. Parallel port (Only available for parallel configuration)6. Intelligent slot7. External battery connector (Only available for long-run model)

8. Line Input circuit breaker 9. Output Grounding terminal 10. Output terminal: connect to mission-critical loads11. Utility input terminal12. External maintenance bypass switch port13. Cooling fan

10-20KVA

613

13

12

8

1

2

3

4

7

9

10

5

11

PRO83310-ERS/ERLPRO83315-ERS/ERLPRO83320-ERS/ERL

Page 53: PROLINK POWER BACKUP SOLUTION

52

Full Specifications

ONLINE UPS

MODEL RO83310-ERS/ERL RO83315-ERS/ERL RO83320-ERS/ERLPHASE 3-phase in / 3-phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% LoadOUTPUTOutput Voltage 3 x 400 VAC (3Ph+N)AC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)

Harmonic Distortion ≦ 2 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90.5% 91.0% 91%ECO Mode 96%Battery Mode 86% 87% 87%BATTERY

Standard Model

Battery Type 12 V / 9 AhNumbers 20 pcs (18-20 adjustable)** 20 pcs (18-20 adjustable)**x 2 strings 20pcs (18-20 adjustable)** x 2 stringsTypical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1A 2A 2ACharging Voltage 273 VDC ± 1%

Long-run Model

Battery TypeDepending on the capacity of external batteries

NumbersCharging Current (max.) 4A 4A 4ACharging Voltage 273 VDC ± 1%

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continously soundingPHYSICAL

Standard Model

UPS: 668x438x266 [6U]Battery pack : 580x438x133 [3U]

UPS: 668 x 438 x 266 [6U]Battery pack : 580x438x133 [3U] x 2 pcs

UPS: 668 x 438 x 266 [6U]Battery pack : 580 x 438 x 133[3U] x 2 pcs

Net Weight (kgs) UPS unit: 42Battery pack: 63

UPS unit: 45Battery pack: 63 x 2 pcs

UPS unit: 45Battery pack: 63 x 2 pcs

Long-run Model

Dimension, DxWxH (mm) 668 x 438 x 266 [6U] 668 x 438 x 266 [6U] 668 x 438 x 266 [6U]Net Weight (kgs) 42 45 45

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 60dB @ 1 Meter Less than 65dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

* L means long-run model**When using internal batteries from 18-19, the unit will de-rate according to below formula: P = PRating x N/20.

Dimension, DxWxH (mm)

Page 54: PROLINK POWER BACKUP SOLUTION

53

Full Specifications

ONLINE UPS

MODEL RO83310-ERS/ERL RO83315-ERS/ERL RO83320-ERS/ERLPHASE 3-phase in / 3-phase outCAPACITY 10000 VA / 9000 W 15000 VA / 13500 W 20000 VA / 18000 WINPUTNominal Voltage 3 x 400 VAC (3Ph+N)Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load Frequency Range 46~54 Hz or 56~64Hz Power Factor ≧ 0.99 @ 100% LoadOUTPUTOutput Voltage 3 x 400 VAC (3Ph+N)AC Voltage Regulation (Batt. Mode) ± 1%Frequency Range (Synchronized Range) 46~54Hz or 56~64HzFrequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 HzCurrent Crest Ratio 3:1 (max.)

Harmonic Distortion ≦ 2 % THD (Linear Load)≦ 5 % THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode ZeroInverter to Bypass Zero

Waveform (Batt. Mode) Pure SinewaveEFFICIENCYAC Mode 90.5% 91.0% 91%ECO Mode 96%Battery Mode 86% 87% 87%BATTERY

Standard Model

Battery Type 12 V / 9 AhNumbers 20 pcs (18-20 adjustable)** 20 pcs (18-20 adjustable)**x 2 strings 20pcs (18-20 adjustable)** x 2 stringsTypical Recharge Time 9 hours recover to 90% capacityCharging Current (max.) 1A 2A 2ACharging Voltage 273 VDC ± 1%

Long-run Model

Battery TypeDepending on the capacity of external batteries

NumbersCharging Current (max.) 4A 4A 4ACharging Voltage 273 VDC ± 1%

INDICATORSLCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery Mode Sounding every 4 secondsLow Battery Sounding every secondOverload Sounding twice every secondFault Continously soundingPHYSICAL

Standard Model

UPS: 668x438x266 [6U]Battery pack : 580x438x133 [3U]

UPS: 668 x 438 x 266 [6U]Battery pack : 580x438x133 [3U] x 2 pcs

UPS: 668 x 438 x 266 [6U]Battery pack : 580 x 438 x 133[3U] x 2 pcs

Net Weight (kgs) UPS unit: 42Battery pack: 63

UPS unit: 45Battery pack: 63 x 2 pcs

UPS unit: 45Battery pack: 63 x 2 pcs

Long-run Model

Dimension, DxWxH (mm) 668 x 438 x 266 [6U] 668 x 438 x 266 [6U] 668 x 438 x 266 [6U]Net Weight (kgs) 42 45 45

ENVIRONMENTOperating Humidity 0-95 % RH @ 0- 40°C (Non-condensing)Noise Level Less than 60dB @ 1 Meter Less than 65dB @ 1 MeterMANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browser

* L means long-run model**When using internal batteries from 18-19, the unit will de-rate according to below formula: P = PRating x N/20.

Dimension, DxWxH (mm)

Power I Series (3P/3P)-Tower

ONLINE UPS

PROLiNK Power I Series (3P/3P) three-phase input / three-phase output, true online double conversion UPS system guarantees to supply consistent and quality electrical power to protect wide range of critical applications such as data centres, medical equipment and call centres.

Harmful effects of harmonic injection are eliminated with the employment of Adaptive Feed Forward Cancellation (AFC) technology. With a UPS system that reflects low harmonic distortion and high input power factor, it is able to lower installation costs by utilizing smaller cables and breakers.

UPS is equipped with 5.7” LCD monitor display with all information and alarm notifications viewable within a single display. PROLiNK Power I series UPS systems have RS-232 and RS 485 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. Power I series is available in models ranging from 10kVA to 200kVA.

The unit has high flexibility in single-phase / three-phase (input/ output) configurations. Parallel redundant configuration that allows four identical units to operate in parallel is included as an option.

In addition, Emergency Power Off (EPO) function is also available for the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

PRO73300-ES/EL SERIES 10-200KVA

• Online double conversion technology with

DSP control

• Output power factor 0.9

• Advanced control with Adaptive Feed Forward

Cancellation (AFC) technology for very low

harmonic distortion

• Very low input current distortion (THDi < 1%)

• Input power factor 0.99 at 10% load

• Output efficiency up to 95%

• Space-saving compact design

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

• Over 60% materials recyclable

• Remaining backup time calculation

• Front access makes maintenance and

replacement easy

• High flexibility in single phase/ three-phase

set-ups

• Parallel redundant operation with up to 4 units

• Varieties of communication options available

• Flexible battery type configuration upon request

(only available for Taurus Pro 400V models)

Page 55: PROLINK POWER BACKUP SOLUTION

54

The Most Versatile Solution For Power ProtectionThe Power I Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and induction motors. The Power I Series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power I Series is available incapacities ranging from 10 to 200kVA.

Online Double Conversion Technology with DSP ControlThe Power I Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves theperformance and efficiency of the UPS.

Advanced Control with Adaptive Feed Forward Cancellation (AFC) TechnologyBy cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.

Low Input Current Distortion (THDi < 1%)AFC cells are used to achieve extremely low distortion values. Power I Series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network.

Input Power Factor 0.99 At 10% LoadLower power losses would result in reduced consumption, lower operation and maintenance costs.

Output Efficiency of up to 95%Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses.

1,20

1,00

0,80

0,60

0,40

0,20

0,000% 25% 50%

LOAD

INPUT POWER FACTOR

PFin

100%

75%

50%

25%

0%0%

SERIES TIPICAL EFFICIENCY

25% 50%

EFFI

CIEN

CY

LOAD

Small Form FactorUtilizes a transformerless technology allows the design of the UPS to be lighter and smaller.

Output Power FactorNowadays IT installation requirements are driving to power sources able to supply loads with leading powerwithout affecting the power capability. Power E Series UPS are able to supply full power without any deratingfor all loads from 0.9 lagging to 0.9 leading. This uniquecharacteristic avoids any UPS over sizing in case of unity or leading power factor as for the loads.

ONLINE UPS

Page 56: PROLINK POWER BACKUP SOLUTION

55

The Most Versatile Solution For Power ProtectionThe Power I Series is designed with the new state of art transformerless PWM technology that can be easily adapted to any kinds of complicated loads such as the non-linear systems (IT systems), highly inductive/ capacitive loads, high-density discharge lamps and induction motors. The Power I Series is designed with 2 important criterions in mind; maximum efficiency and energy conservation. The unit also comes with a small form factor to allow for minimum installation effort. Furthermore, a parallel redundant system is integrated to allow two UPS models to operate in parallel as backup for each other. The Power I Series is available incapacities ranging from 10 to 200kVA.

Online Double Conversion Technology with DSP ControlThe Power I Series is able provide a higher load up-time and effective insulation against network disturbance with its online double conversion technology. A Digital Signal Processor (DSP) controller improves theperformance and efficiency of the UPS.

Advanced Control with Adaptive Feed Forward Cancellation (AFC) TechnologyBy cancelling both the input current and the output voltage harmonics, the harmful effects of harmonic injection can be eliminated and this enhances the load integrity.

Low Input Current Distortion (THDi < 1%)AFC cells are used to achieve extremely low distortion values. Power I Series is able to obtain a low input current distortion at THDi < 1% under full load and a THDi < 5% under smaller load (i.e. 10% of load). This will prevent distortion of electrical network upstream and thus, result in the reduction of cable usage and protective devices in the electrical network.

Input Power Factor 0.99 At 10% LoadLower power losses would result in reduced consumption, lower operation and maintenance costs.

Output Efficiency of up to 95%Designed with a DSP controller and fourth generation IGBT transistors, the UPS is able to achieve extremely high efficiency of up to 95%. With such high ratings, components in the UPS are not only protected but also prolonged due to the decrease in heat losses.

1,20

1,00

0,80

0,60

0,40

0,20

0,000% 25% 50%

LOAD

INPUT POWER FACTOR

PFin

100%

75%

50%

25%

0%0%

SERIES TIPICAL EFFICIENCY

25% 50%

EFFI

CIEN

CY

LOAD

Small Form FactorUtilizes a transformerless technology allows the design of the UPS to be lighter and smaller.

Output Power FactorNowadays IT installation requirements are driving to power sources able to supply loads with leading powerwithout affecting the power capability. Power E Series UPS are able to supply full power without any deratingfor all loads from 0.9 lagging to 0.9 leading. This uniquecharacteristic avoids any UPS over sizing in case of unity or leading power factor as for the loads.

ONLINE UPS

Front Access conceptAn important consideration has been given during the UPS design phase to create a system that allows users to access the unit’s electronic cards and powercomponents with minimum effort. All electronic boards and components can be accessed from the front panel for easy maintenance and replacement activities.

Versatile Single-Phase / Three-Phase set-upsThis highly versatile UPS is designed with different types of setting-up options;• Three-phase input / Three-phase output (III/III) • Three-phase input / Single phase output (III/I)• Single Phase input / Single Phase output (I/I)• Single Phase input / Three Phase output (I/III)

Control Components are designed to with stand all kinds of loadsIn the Power I Series , the control components are designed to withstand all types of loads. These include loads such as; resistive, capacitive, non-linear, high-density discharge lamps, induction motors, speed drives etc. This makes the UPS extremely compatible with many types of electronics. Better yet, the UPS comes with a wide array of parameters that can be programmed locally or remotely to fit different types of environment.

N+1 RedundancyA parallel redundant system allows 4 UPS models to operate in parallel and as backup for each other.

Variety Of Communications And OptionAvailableThe UPS has provided the following standardcommunication selections:• Relay interface• RS-232/485 port• 1 × SNMP slot• Modbus RTU / SEC protocol• 2 × connectors for parallel connection

Made of 60% RecyclableMaterialsWhen it comes to conserving the environment, PROLiNK is committed to play a part by designing their UPS products using recyclable materials.

Back-up Time indicatorWith the use of simple algorithms, an estimated remaining back-up time can be calculated and indications will be reflected on a LCD panel.

5.7” Multiple Languages Graphical LCDDisplayOur team of specialists has gathered together to revolutionize the UPS usability by adding in a 5.7” LCD monitor display with all information and alarm notifications viewable within a single display.

ONLINE UPS

Page 57: PROLINK POWER BACKUP SOLUTION

56

23

1

ONLINE UPS

Rear Panel

1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slot5. Input circuit breaker

6. Maintenance bypass switch7. Output switch8. Battery switch9. Input/Output/Battery Terminal10. Parallel port (only available for parallel configuration)

10-200KVA

PRO73380-EL

5

6

8

7

9

4

23

1

10

5

6

87

4

12

103

PRO733160-ELPRO733200-EL

PRO733100-ELPRO733120-EL

8

5

7

6

4

9

10

PRO73310-ES/ELPRO73315-ES/ELPRO73320-ES/ELPRO73330-ES/ELPRO73340-ES/EL

PRO73360-EL

2

4

5

6

8

7

9

3

1

10

4

21

310

5

6

8

7

9

Page 58: PROLINK POWER BACKUP SOLUTION

57

23

1

ONLINE UPS

Rear Panel

1. Relay interface2. Emergency Power Off (EPO)3. RS-232 COM ports4. Intelligent Slot5. Input circuit breaker

6. Maintenance bypass switch7. Output switch8. Battery switch9. Input/Output/Battery Terminal10. Parallel port (only available for parallel configuration)

10-200KVA

PRO73380-EL

5

6

8

7

9

4

23

1

10

5

6

87

4

12

103

PRO733160-ELPRO733200-EL

PRO733100-ELPRO733120-EL

8

5

7

6

4

9

10

PRO73310-ES/ELPRO73315-ES/ELPRO73320-ES/ELPRO73330-ES/ELPRO73340-ES/EL

PRO73360-EL

2

4

5

6

8

7

9

3

1

10

4

21

310

5

6

8

7

9

Full Specifications

ONLINE UPS

MODELPRO

73310-ES/EL

PRO73315-ES/EL

PRO73320-ES/EL

PRO73330-ES/EL

PRO73340-ES/EL

PRO73360-

EL

PRO73380-

EL

PRO733100-

EL

PRO733120-

EL

PRO733160-

EL

PRO733200-

ELPHASE 3-phase in / 3-phase out

CAPACITY 10KVA/9KW

15KVA/13.5KW

20KVA/18KW

30KVA/27KW

40KVA/36KW

60KVA/54KW

80KVA/72KW

100KVA/90KW

120KVA/108KW

160KVA/144KW

200KVA/180KW

INPUTNominal Voltage 3 x 400V (3Ph + N)Acceptable Voltage Range +15% or –20%Frequency 50 / 60 Hz ±5 %

Total Harmonic Distortion (THDi)

< 1.5% @ 100% load< 2.5% @ 50% load< 6.0% @ 10% load

< 1.0% @ 100% load< 2.0% @ 50% load< 5.0% @ 10% load

< 1.5% @ 100% load< 2.0% @ 50% load< 6.0% @ 10% load

Current Limitation High overload: PFC Limit (discharging batteries)Power Factor 1.0INVERTERNominal Voltage 3 x 400V (3Ph + N)Precision Stationary: ±1% ; Transitory: ±2% (load variations 100-0-100%)Frequency 50/60 Hz synchronised ±4 % With mains absent ±0.05%Max. Synchronisation Speed 10 Hz/sWaveform Pure SinewaveTotal Harmonic Distortion (THDv) < 0.5% (Linear Load) ; < 1.5% (Non-linear Load)Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)Dynamic Recovery Time 10 ms. at 98 % of the static valueAdmissible Overload Phase Overload: 125% for 10 min., 150% for 60s ; Total Overload: 112.5% for 10 min., 135% for 60sAdmissible Crest Factor 3.4 : 1 3.2 :1 2.8 : 1 3.2 :1 3.0 :1Admissible Power Factor 0.7 inductive to 0.7 capacitiveImbalance Output Voltage @ 100%Unbalanced Load <1%

Current Limit High overload, short-circuit: RMS Voltage Limit ; High Crest-Factor current: Peak Voltage LimitSTATIC BYPASSType Solid stateVoltage 3x400V (3Ph + N)Frequency 50/60 HzActivation Criterion Microprocessor controlTransfer Time ZeroAdmissible Overload 400% for 10 sec.Transfer to Bypass Immediate, for overloads above 150%Retransfer Automatically retransfer after alarm is clearMAINTENANCE BYPASSType Without interruptionVoltage 3 x 400V (3Ph + N)Frequency 50/60 Hz

91.0% 91.5% 92.0% 93.0% 93.5% 94.0% 95.0% 94.5% 94.0% 95.0% 95.0%BATTERYBuilt-in Battery Type (2x31) 12V 4.5Ah 12V 4.5Ah 12V 7Ah 12V 9Ah 12V 12Ah -Back-up Time (minutes) 5 3 5 3 3 -Max. Charging Current 23.5 A 47 A 70.5 A 188 APHYSICALDimension, D x W x H (mm) 770 x 450 x 1100 805 x 590 x 1320 850 x 900 x 1900Net Weight (without batteries) (Kg) 83 88 95 113 120 185 265 290 540 550

Net Weight (w/built-in batteries) (Kg) 210 212 215 310 400 -

*NOTE: When temperature is above 30°C, the output power will be derated. The output power is derated to 90% at 31°C -35°C and 80% at 36°C -40°C.*

Page 59: PROLINK POWER BACKUP SOLUTION

58

Giant Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Giant Series (1P/1P) true online double conversion UPS systems are

using Galvanic Isolation design to withstand all kinds of loads. The UPS applies

an advanced digital controller to control the double conversion system, and with

an isolated transformer at the output to protect the load and the UPS itself. The

system has unique ventilation design for effective heat dissipation. All internal

PCBAs are coated to withstand harsh environment. The unit is able to accept

wide input voltage and frequency range to withstand robust environment.

Users can easily monitor and access to their UPS status from a comprehensive

LCD display. The UPS systems have USB and RS-232 communication ports as

standard, with a built-in intelligent slot for additional adapters, protocol

converters and relay contact cards. SNMP option is also available for power

management via SNMP manager and web browser. Giant (1P/1P) series are

available in models ranging from 6kVA to 10kVA.

PRO600-L SERIES 6-10KVA

• Galvanic isolation design to withstand all kinds of loads

• Output power factor 0.8

• Fully coating PCBAs to withstand harsh environment

• Unique ventilation design for effective heat dissipation

• Wide input voltage and frequency range

to withstand robust environment

• High short-circuit and overload capabilities

• Maintenance bypass switch (option)

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 60: PROLINK POWER BACKUP SOLUTION

59

Giant Series (1P/1P)-Tower

ONLINE UPS

PROLiNK Giant Series (1P/1P) true online double conversion UPS systems are

using Galvanic Isolation design to withstand all kinds of loads. The UPS applies

an advanced digital controller to control the double conversion system, and with

an isolated transformer at the output to protect the load and the UPS itself. The

system has unique ventilation design for effective heat dissipation. All internal

PCBAs are coated to withstand harsh environment. The unit is able to accept

wide input voltage and frequency range to withstand robust environment.

Users can easily monitor and access to their UPS status from a comprehensive

LCD display. The UPS systems have USB and RS-232 communication ports as

standard, with a built-in intelligent slot for additional adapters, protocol

converters and relay contact cards. SNMP option is also available for power

management via SNMP manager and web browser. Giant (1P/1P) series are

available in models ranging from 6kVA to 10kVA.

PRO600-L SERIES 6-10KVA

• Galvanic isolation design to withstand all kinds of loads

• Output power factor 0.8

• Fully coating PCBAs to withstand harsh environment

• Unique ventilation design for effective heat dissipation

• Wide input voltage and frequency range

to withstand robust environment

• High short-circuit and overload capabilities

• Maintenance bypass switch (option)

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

21

3

4

6

7

5

11

8

10

9

12

ONLINE UPS

Rear Panel

1. Intelligent slot

2. External battery connector

3. RS-232 communication port

4. Dry contact port

5. USB communication port

6. Emergency power off function connector (EPO connector)

7. Maintenance bypass switch (option)

8. Output Breaker

9. Bypass Breaker

10. Input circuit breaker

11. Output/Bypass/Input terminal

12. Cooling fan

6-10KVA

PRO606-L/PRO608-L/PRO610-L

12

Page 61: PROLINK POWER BACKUP SOLUTION

60

Full Specifications

ONLINE UPS

MODEL PRO606-L PRO608-L PRO610-L

PHASE Single phase with ground

CAPACITY 6KVA / 4.8KW 7.5KVA / 6KW 10KVA / 8KW

INPUT

Nominal Voltage 208VAC/220VAC/230VAC

Voltage Range 165VAC ~ 275VAC @ 16 pcs of batteries185VAC ~ 275VAC @ 18 pcs of batteries

Frequency 40 Hz ~ 55 Hz @ 50Hz system56 Hz ~ 64 Hz @ 60Hz system

OUTPUT

Output Voltage 208VAC/220VAC/230VAC

Voltage Regulation ± 1%

Frequency Range (Synchronized Range) 45Hz ~ 55 Hz or 56 Hz ~ 64 Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz

Current Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer TimeAC to DC Zero

Inverter to Bypass Zero

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

AC Mode 88.3%

Battery Mode 92%

EXTERNAL BATTERY

Numbers 16 pcs 18 pcs 16pcs 18 pcs 16pcs 18 pcs

Charging Current (max.) Default :8 A ± 10%; Max: 2A, 4A, 8A(Adjustable)

Charging Voltage 218.4 V ± 1% 245.7 V ± 1% 218.4 V ± 1% 245.7 V ± 1% 218.4 V ± 1% 245.7 V ± 1%

INDICATORS

LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM

Battery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continously sounding

PHYSICAL

Dimensions, D x W x H (mm) 562 x 250 x 830

Net Weight (Kgs) 62 78 86

ENVIRONMENT

Operating Temperature 0 ~ 50°C(battery life cycle will be shorten when temperature is above 25°C)

Operating Humidity < 95 % and non-condensing

Noise Level Less than 60dBA @ 1 Meter

MANAGEMENT

Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC

Dry Contact Five signals: AC failure, low battery, UPS alarm, bypass and UPS fault

Optional SNMP Power management from SNMP manager and web browser

Page 62: PROLINK POWER BACKUP SOLUTION

61

Full Specifications

ONLINE UPS

MODEL PRO606-L PRO608-L PRO610-L

PHASE Single phase with ground

CAPACITY 6KVA / 4.8KW 7.5KVA / 6KW 10KVA / 8KW

INPUT

Nominal Voltage 208VAC/220VAC/230VAC

Voltage Range 165VAC ~ 275VAC @ 16 pcs of batteries185VAC ~ 275VAC @ 18 pcs of batteries

Frequency 40 Hz ~ 55 Hz @ 50Hz system56 Hz ~ 64 Hz @ 60Hz system

OUTPUT

Output Voltage 208VAC/220VAC/230VAC

Voltage Regulation ± 1%

Frequency Range (Synchronized Range) 45Hz ~ 55 Hz or 56 Hz ~ 64 Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz

Current Crest Ratio 3:1

Harmonic Distortion ≦ 3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Transfer TimeAC to DC Zero

Inverter to Bypass Zero

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

AC Mode 88.3%

Battery Mode 92%

EXTERNAL BATTERY

Numbers 16 pcs 18 pcs 16pcs 18 pcs 16pcs 18 pcs

Charging Current (max.) Default :8 A ± 10%; Max: 2A, 4A, 8A(Adjustable)

Charging Voltage 218.4 V ± 1% 245.7 V ± 1% 218.4 V ± 1% 245.7 V ± 1% 218.4 V ± 1% 245.7 V ± 1%

INDICATORS

LCD Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

ALARM

Battery Mode Sounding every 4 seconds

Low Battery Sounding every second

Overload Sounding twice every second

Fault Continously sounding

PHYSICAL

Dimensions, D x W x H (mm) 562 x 250 x 830

Net Weight (Kgs) 62 78 86

ENVIRONMENT

Operating Temperature 0 ~ 50°C(battery life cycle will be shorten when temperature is above 25°C)

Operating Humidity < 95 % and non-condensing

Noise Level Less than 60dBA @ 1 Meter

MANAGEMENT

Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC

Dry Contact Five signals: AC failure, low battery, UPS alarm, bypass and UPS fault

Optional SNMP Power management from SNMP manager and web browser

Giant Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Giant Series (3P/1P) true online double conversion UPS systems are

using Galvanic Isolation design to withstand all kinds of loads. The UPS applies

an advanced digital controller to control the double conversion system, and with

an isolated transformer at the output to protect the load and the UPS itself. The

system has unique ventilation design for effective heat dissipation. All internal

PCBAs are coated to withstand harsh environment. The unit is able to accept

wide input voltage and frequency range to withstand robust environment.

Users can easily monitor and access to their UPS status from a comprehensive

LCD display. The UPS systems have USB and RS-232 communication ports as

standard, with a built-in intelligent slot for additional adapters, protocol

converters and relay contact cards. SNMP option is also available for power

management via SNMP manager and web browser. Giant (3P/1P) series are

available in models ranging from 6kVA to 10kVA.

PRO63100-L SERIES 6-10KVA

• Galvanic isolation design to withstand all kinds of loads

• Output power factor 0.8

• Fully coating PCBAs to withstand harsh environment

• Unique ventilation design for effective heat dissipation

• Wide input voltage and frequency range

to withstand robust environment

• High short-circuit and overload capabilities

• Maintenance bypass switch (option)

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 63: PROLINK POWER BACKUP SOLUTION

62

ONLINE UPS

Rear Panel

1. Intelligent slot

2. External battery connector

3. RS-232 communication port

4. Dry contact port

5. USB communication port

6. Emergency power off function connector (EPO connector)

7. Maintenance bypass switch (option)

8. Output Breaker

9. Bypass Breaker

10. Input circuit breaker

11. Out put/Bypass/Input terminal

12. Cooling fan

6-10KVA

1

2

3

54

8

6

7

10

9

11

PRO63106-L / PRO63108-L / PRO63110-L

12

12

Page 64: PROLINK POWER BACKUP SOLUTION

63

ONLINE UPS

Rear Panel

1. Intelligent slot

2. External battery connector

3. RS-232 communication port

4. Dry contact port

5. USB communication port

6. Emergency power off function connector (EPO connector)

7. Maintenance bypass switch (option)

8. Output Breaker

9. Bypass Breaker

10. Input circuit breaker

11. Out put/Bypass/Input terminal

12. Cooling fan

6-10KVA

1

2

3

54

8

6

7

10

9

11

PRO63106-L / PRO63108-L / PRO63110-L

12

12

Full Specifications

ONLINE UPS

MODEL PRO63106-L PRO63108-L PRO63110-LPHASE 3-phase in / 1-phase out

CAPACITY 6KVA / 4.8KW 7.5KVA / 6KW 10KVA / 8KW

INPUTNominal Voltage 3 x 360VAC/380VAC/400VAC(3Ph + G or 3Ph + N + G)

Acceptable Voltage Range 286VAC ~ 476VAC @ 16 pcs of batteries320VAC ~ 476VAC @ 18 pcs of batteries

Frequency 40Hz ~ 55Hz @ 50Hz system57Hz ~ 63Hz @ 60Hz system

OUTPUTNominal Voltage 208VAC/220VAC/230VAC /240VAC (Selectable)

Connection Type Hardwire 3-wire (1Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Waveform ±5%

Frequency 50 Hz

Frequency Stability ± 1%

Frequency Synchronisation Range ± 4Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Crest Factor 3:1

Total Harmonic Distortion (THDv) <3% (Linear Load) ; <5% (Non-linear Load)

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <100 ms recover to 90% of nominal voltage

Transfer Time 0 ms

Overload Capability 110%~120% for 30 min. ; 120% ~ 130% for 5 min; >130% for 10 sec.

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 3-wire (1Ph+N+G)

Input Voltage Range 165VAC ~ 275VAC @ 16 pcs of batteries185VAC ~ 275VAC @ 18 pcs of batteries

Overload Capability 1.5 In~1.8 In 30s~ 1h

Short-circuit Capability 1.8 In ~ >2.0 In 200ms~30s

EFFICIENCYLine Mode 87%

Battery Mode 92%

EXTERNAL BATTERYNumbers 16pcs 18pcs 16pcs 18pcs 16pcs 18pcs

Charging Current (Max.) 2A/4A/8A(selectable)

Charging Voltage 218.4 V ± 1% 245.7 V ± 1% 218.4 V ± 1% 245.7 V ± 1% 218.4 V ± 1% 245.7 V ± 1%

PHYSICALDimensions, D x W x H (mm) 815 x 250 x 826

Net Weight (Kgs) 85 100 104

ENVIRONMENTOperating Temperature 0~ 40°C

Operating Humidity 0~90% (non-condensing)

Noise Level Less than 58dBA @ 1 Meter

MANAGEMENTSmart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC

Optional SNMP Power management from SNMP manager and web browser

Page 65: PROLINK POWER BACKUP SOLUTION

64

Giant I Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Giant I Series (3P/1P) is a new series that uses true online double conversion technology with galvanic isolation transformer design which guarantees to supply consistent and quality electrical power to protect your mission critical applications. DSP control technology is implemented for the system to have improved performance and high reliability.

The front access design makes it easy for users to perform maintenance and replacement activities. The system offers easy integration into existing electrical network or generator. It has robust electrical performance to prevent damage from top and bottom connections and cabinet is using screw-less cabinet design. The system has unique ventilation design for effective heat dissipation. All internal PCBAs are coated to withstand harsh environment.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. Giant I (3P/1P) series is available in models ranging from 10kVA to 40kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63100-GL SERIES 10-40KVA

• True online double conversion with DSP control

• Robust electrical performance to prevent damage from top and bottom connections

• Screwless cabinet design and fully coating PCBAs to withstand harsh environment

• Unique ventilation design for effective heat dissipation

• Accept dual-mains inputs

• High short-circuit and overload capabilities

• Easy integration into existing electrical networks or generator

• Parallel capability up to 4 units

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 66: PROLINK POWER BACKUP SOLUTION

65

Giant I Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Giant I Series (3P/1P) is a new series that uses true online double conversion technology with galvanic isolation transformer design which guarantees to supply consistent and quality electrical power to protect your mission critical applications. DSP control technology is implemented for the system to have improved performance and high reliability.

The front access design makes it easy for users to perform maintenance and replacement activities. The system offers easy integration into existing electrical network or generator. It has robust electrical performance to prevent damage from top and bottom connections and cabinet is using screw-less cabinet design. The system has unique ventilation design for effective heat dissipation. All internal PCBAs are coated to withstand harsh environment.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. Giant I (3P/1P) series is available in models ranging from 10kVA to 40kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63100-GL SERIES 10-40KVA

• True online double conversion with DSP control

• Robust electrical performance to prevent damage from top and bottom connections

• Screwless cabinet design and fully coating PCBAs to withstand harsh environment

• Unique ventilation design for effective heat dissipation

• Accept dual-mains inputs

• High short-circuit and overload capabilities

• Easy integration into existing electrical networks or generator

• Parallel capability up to 4 units

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

ONLINE UPS

Rear Panel

1. Interface

2. Input/ Output / Bypass/ Battery Terminals

3. Breakers and switch

4. Cooling Fan

5. Communication ports / slot / terminals

6. Cold start button. This button is

located same position for whole series.

10-40KVA

3

2

6

5

6

5

3

2

4

4

Front Rear

Front Rear

PRO63110-GL / PRO63115-GL / PRO63120-GL / PRO63130-GL

PRO63140-GL

Page 67: PROLINK POWER BACKUP SOLUTION

66

Full Specifications

ONLINE UPS

MODEL PRO63110-GL PRO63115-GL PRO63120-GL PRO63130-GL PRO63140-GLCAPACITY 10 KVA / 8 KW 15 KVA / 12 KW 20 KVA / 16 KW 30 KVA / 24 KW 40 KVA / 32 KWINPUTNominal Voltage 3 x 380VAC/400VAC (3Ph + N or 3Ph + N + G)Acceptable Voltage Range 285VAC ~ 475VACFrequency 50Hz/60Hz ±5 Hz (±10%)INVERTERNominal Voltage 220VAC/230VAC/240VAC (Adjustable)Waveform Pure Sinewave

Output Voltage Stability

Steady state ±1%Transient state ±5%

Frequency 50 Hz / 60 HzFrequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)Frequency Synchronisation Speed 1~2 Hz/sPower Factor 0.8Crest Factor 3:1

Total Harmonic Distortion (THDv) < 2% (Linear Load) < 5% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) <±5% ; 20%->100%->20% (R Load) ±3%Dynamic Recovery Time (III Grade) 0%~100% RCD load ; <60 ms recover to 90% of nominal voltageTransfer Time 0 msOverload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200msShort-circuit Capability 60~100msTransient Response Time < 5msBYPASSConnection Type Hardwire 3-wire (1Ph+N+G)Input Voltage Range 220VAC ± 25%

Overload Capability/Short-circuit Capability1.5 In~1.8 In 1h~30s

1.8 In ~ >2.0 In 30s~200msSYSTEM

≧90%ECO Mode (Non-parallel models) YesEPO Function YesStandard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 SafetyBATTERY & CHARGER

Type 6 pulseRated output voltage 384 VDCCharger voltage 190VDC ~ 435VDC (Adjustable)Charging current(max) Default 10A, Maximum=Capacity/Battery Voltage Default 10A, Maximum 40A, 5A@Full load

BatteryType Support VRLA BatteryNumbers 32 pcs (29 ~ 32 adjustable)Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)Dimensions, D x W x H (mm) 656 x 405 x 817 821 x 432 x 1159Net Weight (Kgs) 118 120 145 193 278ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nomina linput voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Operating Humidity 0~90% (non-condensing)Noise Level Less than 70dB @ 1 MeterMANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MACDry Contacts 6 outputs and 2 inputsOptional SNMP Power management from SNMP manager and web browser

Giant I Series (3P/3P)-Tower

ONLINE UPS

PROLiNK Giant I Series (3P/3P) three-phase output UPS system is designed based on true online double conversion technology and using galvanic isolation transformer design which guarantees to supply consistent and quality electrical power to protect critical applications. The UPS systems accept dual-mains inputs. DSP control technology is implemented for the system to have improved performance and high reliability.

The front access design makes it easy for users to perform maintenance and replacement activities. Intelligent battery management feature is implemented in the UPS system to prolong battery life cycle.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. Giant I (3P/3P) series is available in models ranging from 10kVA to 200kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63300-L SERIES 10-200KVA

• Online double-conversion

• DSP technology guarantees high reliability

• True galvanic isolation transformer design

• Control designed to withstand all kinds of loads

• Intelligent battery management to prolong battery lifecycle

• Redundant fan design and independent ventilation enhance durable

operation under harsh environment

• Adjustable battery numbers

• Accept dual-mains input

• Parallel operation with up to 4 units (option)

• Varieties of communication options available

• Optional 7" touch LCD

• Reverse phase frequency operation and supports non-neutral input

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 68: PROLINK POWER BACKUP SOLUTION

67

Giant I Series (3P/3P)-Tower

ONLINE UPS

PROLiNK Giant I Series (3P/3P) three-phase output UPS system is designed based on true online double conversion technology and using galvanic isolation transformer design which guarantees to supply consistent and quality electrical power to protect critical applications. The UPS systems accept dual-mains inputs. DSP control technology is implemented for the system to have improved performance and high reliability.

The front access design makes it easy for users to perform maintenance and replacement activities. Intelligent battery management feature is implemented in the UPS system to prolong battery life cycle.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. The UPS systems have USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser. Giant I (3P/3P) series is available in models ranging from 10kVA to 200kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63300-L SERIES 10-200KVA

• Online double-conversion

• DSP technology guarantees high reliability

• True galvanic isolation transformer design

• Control designed to withstand all kinds of loads

• Intelligent battery management to prolong battery lifecycle

• Redundant fan design and independent ventilation enhance durable

operation under harsh environment

• Adjustable battery numbers

• Accept dual-mains input

• Parallel operation with up to 4 units (option)

• Varieties of communication options available

• Optional 7" touch LCD

• Reverse phase frequency operation and supports non-neutral input

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 69: PROLINK POWER BACKUP SOLUTION

68

Full Specifications

ONLINE UPS

MODEL PRO63310-L

PRO63315-L

PRO63320-L

PRO63330-L

PRO63340-L

PRO63360-L

PRO63380-L

PRO633100-L

PRO633120-L

PRO633160-L

PRO633200-L

CAPACITY 10 KVA / 8 KW

15KVA / 12KW

20 KVA / 16 KW

30 KVA / 24 KW

40 KVA / 32 KW

60 KVA / 48 KW

80 KVA / 64 KW

100 KVA / 80 KW

120 KVA / 96KW

160 KVA / 128KW

200 KVA / 160KW

INPUTNominal Voltage 3 x 380VAC/400VAC (3Ph + N)Acceptable Voltage Range 285VAC ~ 475VACFrequency 50/60 Hz ± 10 %INVERTERNominal Voltage 3 x 380VAC/400VAC (3Ph + N)

Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)

Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz

Max. Synchronization Speed ±1 Hz/sWaveform Pure SinewaveTotal Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)

Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)Dynamic Recovery Time 3 cycles at 90 % of the static valueAdmissible Overload 110% for 10min; 150% for 60sec ; >160% for 200msAdmissible Crest Factor 3:1Admissible Power Factor 0.6~1 (inductive or capacitive)Imbalance Output Voltage @ 100% Unbalanced Load <1%

Current Limit High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit

STATIC BYPASSType Solid stateVoltage 3 x 380VAC/400VAC (3Ph + N)Frequency 50/60 HzActivation Criterion Microprocessor controlTransfer Time ZeroAdmissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200msTransfer to Bypass Immediate, for overloads above 160%Retransfer Automatic after alarm clearMAINTENANCE BYPASSType Without interruptionVoltage 3 x 400V (3Ph + N)Frequency 50/60 Hz

Overall Line Mode 89% 90% 91% 92%Battery Mode 90% 91% 92% 93%

BATTERY & CHARGERBattery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)Charging Method CC/CVPrecision ±1%Charging Current Default 10A,Maximum*=Capacity/Battery Default: 10A. Max. 40ACharging Voltage 432 VDC (Based on 32pcs batteries)PHYSICALDimensions, D x W x H (mm) 656 x 405 x 817 656 x 405

x 941 821 x 432 x 1159 975 x 554 x 1286 975 x 635 x 1326 1051x705x1646

Net Weight (Kgs) 118 120 145 193 278 365 471 573 650 760 840* The maximum current is never higher than 40A.

Page 70: PROLINK POWER BACKUP SOLUTION

69

Full Specifications

ONLINE UPS

MODEL PRO63310-L

PRO63315-L

PRO63320-L

PRO63330-L

PRO63340-L

PRO63360-L

PRO63380-L

PRO633100-L

PRO633120-L

PRO633160-L

PRO633200-L

CAPACITY 10 KVA / 8 KW

15KVA / 12KW

20 KVA / 16 KW

30 KVA / 24 KW

40 KVA / 32 KW

60 KVA / 48 KW

80 KVA / 64 KW

100 KVA / 80 KW

120 KVA / 96KW

160 KVA / 128KW

200 KVA / 160KW

INPUTNominal Voltage 3 x 380VAC/400VAC (3Ph + N)Acceptable Voltage Range 285VAC ~ 475VACFrequency 50/60 Hz ± 10 %INVERTERNominal Voltage 3 x 380VAC/400VAC (3Ph + N)

Precision Stationary: ±1% Transitory: ±5% (load variations 100-0-100%)

Frequency 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz

Max. Synchronization Speed ±1 Hz/sWaveform Pure SinewaveTotal Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)

Phase Displacement 120º ±1% (balanced load) ; 120º ±2% (imbalances 50% of the load)Dynamic Recovery Time 3 cycles at 90 % of the static valueAdmissible Overload 110% for 10min; 150% for 60sec ; >160% for 200msAdmissible Crest Factor 3:1Admissible Power Factor 0.6~1 (inductive or capacitive)Imbalance Output Voltage @ 100% Unbalanced Load <1%

Current Limit High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit

STATIC BYPASSType Solid stateVoltage 3 x 380VAC/400VAC (3Ph + N)Frequency 50/60 HzActivation Criterion Microprocessor controlTransfer Time ZeroAdmissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200msTransfer to Bypass Immediate, for overloads above 160%Retransfer Automatic after alarm clearMAINTENANCE BYPASSType Without interruptionVoltage 3 x 400V (3Ph + N)Frequency 50/60 Hz

Overall Line Mode 89% 90% 91% 92%Battery Mode 90% 91% 92% 93%

BATTERY & CHARGERBattery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)Charging Method CC/CVPrecision ±1%Charging Current Default 10A,Maximum*=Capacity/Battery Default: 10A. Max. 40ACharging Voltage 432 VDC (Based on 32pcs batteries)PHYSICALDimensions, D x W x H (mm) 656 x 405 x 817 656 x 405

x 941 821 x 432 x 1159 975 x 554 x 1286 975 x 635 x 1326 1051x705x1646

Net Weight (Kgs) 118 120 145 193 278 365 471 573 650 760 840* The maximum current is never higher than 40A.

Giant Industrial Series (3P/1P)-Tower

ONLINE UPS

PROLiNK Giant Industrial Series are single-phase output UPS systems which apply a true online double-conversion technology. Double conversion between input/output, battery and bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. All Giant Industrial Series UPS systems accept dual-mains inputs.

DSP control technology is implemented for the UPS system to improve performance and high reliability. The front access design makes it easy for users to perform maintenance and replacement activities. The system can have easy integration into existing electrical network or generator. During wiring connection, the unit can be accessed either from top or bottom under different environmental conditions.

The system has robust electrical performance to prevent damage from top and bottom connections and cabinet is using screw-less cabinet design. All internal PCBAs are coated to withstand harsh environment.

PROLiNK Giant Industrial Series has built-in high short circuit protection. Once short circuit occurs, this protection will be activated. The load will stay protected and the UPS will remain intact.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. Potential free dry contacts are provided for UPS alarm monitoring via hard wire. The UPS systems have USB and RS-485 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Giant Industrial series (220VDC) (3P/1P) series is available in models ranging from 10kVA to 120kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63100-L-220 SERIES 10-120KVA

• True online double conversion with DSP control• Robust electrical performance to prevent damage from top and bottom connections• Screwless cabinet design and fully coating PCBAs to withstand harsh environment • Unique ventilation design for effective heat dissipation• Flexible battery configuration adapts different applications• Accepts dual-mains inputs• Front access makes maintenance and replacement easy• High short-circuit and overload• Easy integration into existing electrical networks or generator• Parallel capability up to 4 units

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 71: PROLINK POWER BACKUP SOLUTION

70

Full Specifications

ONLINE UPS

MODEL PRO63110-L-220

PRO63115-L-220

PRO63120-L-220

PRO63130-L-220

PRO63140-L-220

PRO63150-L-220

PRO63160-L-220

PRO63180-L-220

PRO631100-L-220

PRO631120-L-220

CAPACITY 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 50KVA/40KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW

INPUTNominal Voltage 3 x 380VAC (3Ph + G or 3Ph + N + G)

Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 50Hz ±5 Hz (±10%)

OUTPUTNominal Voltage 220VAC/230VAC/240VAC (Selectable)

Connection Type Hardwire 3-wire (1Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Transient state ±5%

Frequency 50 Hz

Frequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.8

Crest Factor 3:1Total Harmonic Distortion (THDv)

<2% (Linear Load)<5% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) <±5% : 20%->100%->20% (R Load) ±3%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <60 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1% (balanced load)120º ±2% (imbalances 50% of the load)

Transfer Time 0 ms

Overload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 3-wire (1Ph+N+G)

Input Voltage Range 220VAC ± 25%

Overload Capability 1.5 In~1.8 In 1h~30s

Short-circuit Capability 1.8 In ~ >2.0 In 30s~200ms

SYSTEM

and 270VDC) 90% 90% 91% 91% 91% 91% 91% 92% 92% 92%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 Safety

BATTERY & CHARGERType 6 pulse 6 pulse or 12 pulse 6 pulseRated output voltage 220 VDC

Charger voltage 216VDC ~ 243VDC (Adjustable)Charging current(max) 20A 20A 20A 20A 40A 40A 40A 40A 40A 40A

Battery

Type Support VRLA Battery

Numbers 18 pcs

Reverse Diode Yes

Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)

Dimensions, DxWxH (mm) 800 x 800 x 1800 800 x 1200 x 1800 800 x 1600 x 1800

Net Weight (Kgs) 365 386 430 645 680 810 960 1160 1300 1580

ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Operating Humidity 0~90% (non-condensing)

Noise Level Less than 70dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Dry Contacts 6 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

Page 72: PROLINK POWER BACKUP SOLUTION

71

Full Specifications

ONLINE UPS

MODEL PRO63110-L-220

PRO63115-L-220

PRO63120-L-220

PRO63130-L-220

PRO63140-L-220

PRO63150-L-220

PRO63160-L-220

PRO63180-L-220

PRO631100-L-220

PRO631120-L-220

CAPACITY 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 50KVA/40KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW

INPUTNominal Voltage 3 x 380VAC (3Ph + G or 3Ph + N + G)

Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 50Hz ±5 Hz (±10%)

OUTPUTNominal Voltage 220VAC/230VAC/240VAC (Selectable)

Connection Type Hardwire 3-wire (1Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Transient state ±5%

Frequency 50 Hz

Frequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.8

Crest Factor 3:1Total Harmonic Distortion (THDv)

<2% (Linear Load)<5% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) <±5% : 20%->100%->20% (R Load) ±3%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <60 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1% (balanced load)120º ±2% (imbalances 50% of the load)

Transfer Time 0 ms

Overload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 3-wire (1Ph+N+G)

Input Voltage Range 220VAC ± 25%

Overload Capability 1.5 In~1.8 In 1h~30s

Short-circuit Capability 1.8 In ~ >2.0 In 30s~200ms

SYSTEM

and 270VDC) 90% 90% 91% 91% 91% 91% 91% 92% 92% 92%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 Safety

BATTERY & CHARGERType 6 pulse 6 pulse or 12 pulse 6 pulseRated output voltage 220 VDC

Charger voltage 216VDC ~ 243VDC (Adjustable)Charging current(max) 20A 20A 20A 20A 40A 40A 40A 40A 40A 40A

Battery

Type Support VRLA Battery

Numbers 18 pcs

Reverse Diode Yes

Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)

Dimensions, DxWxH (mm) 800 x 800 x 1800 800 x 1200 x 1800 800 x 1600 x 1800

Net Weight (Kgs) 365 386 430 645 680 810 960 1160 1300 1580

ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Operating Humidity 0~90% (non-condensing)

Noise Level Less than 70dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Dry Contacts 6 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

ONLINE UPS

Users can easily monitor and access to their UPS status from a comprehensive LCD display. Potential free dry contacts are provided for UPS alarm monitoring via hard wire. The UPS systems have USB and RS-485 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Giant Industrial series (384VDC) (3P/1P) series is available in models ranging from 10kVA to 120kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63100-L-384 SERIES 10-120KVA

• True online double conversion with DSP control• Robust electrical performance to prevent damage from top and bottom connections• Screwless cabinet design and fully coating PCBAs to withstand harsh environment • Unique ventilation design for effective heat dissipation• Flexible battery configuration adapts different applications• Accepts dual-mains inputs• Front access makes maintenance and replacement easy• High short-circuit and overload• Easy integration into existing electrical networks or generator• Parallel capability up to 4 units

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

PROLiNK Giant Industrial Series are single-phase output UPS systems which apply a true online double-conversion technology. Double conversion between input/output, battery and bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. All Giant Industrial Series UPS systems accept dual-mains inputs.

DSP control technology is implemented for the UPS system to improve performance and high reliability. The front access design makes it easy for users to perform maintenance and replacement activities. The system can have easy integration into existing electrical network or generator. During wiring connection, the unit can be accessed either from top or bottom under different environmental conditions.

The system has robust electrical performance to prevent damage from top and bottom connections and cabinet is using screw-less cabinet design. All internal PCBAs are coated to withstand harsh environment.

PROLiNK Giant Industrial Series has built-in high short circuit protection. Once short circuit occurs, this protection will be activated. The load will stay protected and the UPS will remain intact.

Giant Industrial Series (3P/1P)-Tower

Page 73: PROLINK POWER BACKUP SOLUTION

72

Full Specifications

ONLINE UPS

MODEL PRO63110-L-384

PRO63120-L-384

PRO63130-L-384

PRO63140-L-384

PRO63160-L-384

PRO63180-L-384

PRO631100-L-384

PRO631120-L-384

CAPACITY 10KVA / 8KW 20KVA / 16KW 30KVA / 24KW 40KVA / 32KW 60KVA / 48KW 80KVA / 64KW 100KVA / 80KW 120KVA / 96KW

INPUTNominal Voltage 3 x 380VAC (3Ph + G or 3Ph + N + G)

Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 50Hz ±5 Hz (±10%)

OUTPUTNominal Voltage 220VAC/230VAC/240VAC (Selectable)

Connection Type Hardwire 3-wire (1Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ± 1%

Transient state ± 5%

Frequency 50 Hz

Frequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.8

Crest Factor 3:1Total Harmonic Distortion (THDv)

<2% (Linear Load)<4% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) <±5% : 20%->100%->20% (R Load) ±3%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <60 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1% (balanced load)120º ±2% (imbalances 50% of the load)

Transfer Time 0 ms

Overload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 3-wire (1Ph+N+G)

Input Voltage Range 220VAC ± 25%

Overload Capability 1.5 In~1.8 In 1h~30s

Short-circuit Capability 1.8 In ~ >2.0 In 30s~200ms

SYSTEM≧90%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 Safety

BATTERY & CHARGERType 6 pulseRated output voltage 384 VDC

Charger voltage 290VDC ~ 435VDC (Adjustable)Charging current(max) 20A 40A 40A 40A 40A 40A 40A 40A

Battery

Type Support VRLA Battery

Numbers 32 Pcs (29 ~ 32 pcs adjustable)

Reverse Diode Yes

Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)

Dimensions, D x W x H (mm) 800 x 800 x 1800 800 x 1200 x 1800

Net Weight (Kgs) 360 400 430 490 610 680 900 920

ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Operating Humidity 0~90% (non-condensing)

Noise Level Less than 70dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Dry Contacts 6 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

Page 74: PROLINK POWER BACKUP SOLUTION

73

Full Specifications

ONLINE UPS

MODEL PRO63110-L-384

PRO63120-L-384

PRO63130-L-384

PRO63140-L-384

PRO63160-L-384

PRO63180-L-384

PRO631100-L-384

PRO631120-L-384

CAPACITY 10KVA / 8KW 20KVA / 16KW 30KVA / 24KW 40KVA / 32KW 60KVA / 48KW 80KVA / 64KW 100KVA / 80KW 120KVA / 96KW

INPUTNominal Voltage 3 x 380VAC (3Ph + G or 3Ph + N + G)

Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 50Hz ±5 Hz (±10%)

OUTPUTNominal Voltage 220VAC/230VAC/240VAC (Selectable)

Connection Type Hardwire 3-wire (1Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ± 1%

Transient state ± 5%

Frequency 50 Hz

Frequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.8

Crest Factor 3:1Total Harmonic Distortion (THDv)

<2% (Linear Load)<4% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) <±5% : 20%->100%->20% (R Load) ±3%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <60 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1% (balanced load)120º ±2% (imbalances 50% of the load)

Transfer Time 0 ms

Overload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 3-wire (1Ph+N+G)

Input Voltage Range 220VAC ± 25%

Overload Capability 1.5 In~1.8 In 1h~30s

Short-circuit Capability 1.8 In ~ >2.0 In 30s~200ms

SYSTEM≧90%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 Safety

BATTERY & CHARGERType 6 pulseRated output voltage 384 VDC

Charger voltage 290VDC ~ 435VDC (Adjustable)Charging current(max) 20A 40A 40A 40A 40A 40A 40A 40A

Battery

Type Support VRLA Battery

Numbers 32 Pcs (29 ~ 32 pcs adjustable)

Reverse Diode Yes

Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)

Dimensions, D x W x H (mm) 800 x 800 x 1800 800 x 1200 x 1800

Net Weight (Kgs) 360 400 430 490 610 680 900 920

ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Operating Humidity 0~90% (non-condensing)

Noise Level Less than 70dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Dry Contacts 6 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

Giant Industrial Series (3P/3P)-Tower

ONLINE UPS

PROLiNK Giant Industrial Series are three-phase output UPS systems which apply a true online double-conversion technology. Double conversion between input/output, battery and bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. All Giant Industrial Series UPS systems accept dual-mains inputs.

DSP control technology is implemented for the UPS system to improve performance and high reliability. The front access design makes it easy for users to perform maintenance and replacement activities. The system can have easy integration into existing electrical network or generator. During wiring connection, the unit can be accessed either from top or bottom under different environmental conditions.

The system has robust electrical performance to prevent damage from top and bottom connections and cabinet is using screw-less cabinet design. All internal PCBAs are coated to withstand harsh environment.

PROLiNK Giant Industrial Series has built-in high short circuit protection. Once short circuit occurs, this protection will be activated. The load will stay protected and the UPS will remain intact.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. Potential free dry contacts are provided for UPS alarm monitoring via hard wire. The UPS systems have USB and RS-485 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Giant Industrial series (384VDC) (3P/3P) series is available in models ranging from 10kVA to 400kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

PRO63300-L-384 SERIES 10-400KVA

• True online double conversion with DSP control• Robust electrical performance to prevent damage from top and bottom connections• Screwless cabinet design and fully coating PCBAs to withstand harsh environment • Unique ventilation design for effective heat dissipation• Flexible battery configuration adapts different applications• Accepts dual-mains inputs• Front access makes maintenance and replacement easy• High short-circuit and overload• Easy integration into existing electrical networks or generator• Parallel capability up to 4 units

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 75: PROLINK POWER BACKUP SOLUTION

74

Full Specifications

ONLINE UPS

MODELPRO63310

-L-384PRO63315

-L-384PRO63320

-L-384PRO63330

-L-384PRO63340

-L-384PRO63360

-L-384PRO63380

-L-384PRO633100

-L-384PRO633120

-L-384PRO633160

-L-384PRO633200

-L-384PRO633250

-L-384PRO633300

-L-384PRO633400

-L-384

CAPACITY 10KVA / 8KW

15KVA / 12KW

20KVA /16KW

30KVA /24KW

40KVA /32KW

60KVA /48KW

80KVA /64KW

100KVA /80KW

120KVA /96KW

160KVA /128KW

200KVA /160KW

250KVA /200KW

300KVA /240KW

400KVA / 320KW

INPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph + N or 3Ph + N + G)Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 50Hz ±5 Hz (±10%)

OUTPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (Selectable)

Connection Type Hardwire 5-wire (3Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Transient state ±5%

Frequency 50 Hz

Frequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.8

Crest Factor 3:1Total Harmonic Distortion (THDv)

< 2% (Linear Load)< 4% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) < ±5% ; 20%->100%->20% (R Load) ±3%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : < 60 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1% (balanced load)120º ±2% (imbalances 50% of the load)

Transfer Time 0 ms

Overload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 5-wire (3Ph+N+G)

Input Voltage Range 220VAC ± 25%

Overload Capability 1.5 In~1.8 In 1h~30s

Short-circuit Capability 1.8 In ~ >2.0 In 30s~200ms

SYSTEM

(At Linear Load) 90% 90% 91% 91% 91% 91% 92% 92% 92% 92% 92% 92% 93% 93%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 Safety

BATTERY & CHARGER

R

Type 6 pulse 6 pulse or 12 pulseRated output voltage 384 VDC

Charger voltage 395VDC ~ 435VDC (Adjustable)Charging current(max) 20A 20A 40A 40A 40A 40A 40A 40A 40A 50A 50A 50A 70A 70A

Battery

Type Support VRLA Battery

Numbers 32 Pcs (29 ~ 32 pcs adjustable)

Reverse Diode No

Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)Dimensions, D x W x H (mm) 800 x 800 x 1800 800 x 1200 x 1800 800 x 1600 x 1800 850x1630

x1900900x 1700

x 1900Net Weight (Kgs) 350 370 420 450 480 730 790 1000 1300 1400 1700 1900 2300 2500

ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Humidity 0~90% (non-condensing)

Noise Level Less than 70dB @ 1 Meter Less than 72dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Dry Contacts 6 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

Page 76: PROLINK POWER BACKUP SOLUTION

75

Full Specifications

ONLINE UPS

MODELPRO63310

-L-384PRO63315

-L-384PRO63320

-L-384PRO63330

-L-384PRO63340

-L-384PRO63360

-L-384PRO63380

-L-384PRO633100

-L-384PRO633120

-L-384PRO633160

-L-384PRO633200

-L-384PRO633250

-L-384PRO633300

-L-384PRO633400

-L-384

CAPACITY 10KVA / 8KW

15KVA / 12KW

20KVA /16KW

30KVA /24KW

40KVA /32KW

60KVA /48KW

80KVA /64KW

100KVA /80KW

120KVA /96KW

160KVA /128KW

200KVA /160KW

250KVA /200KW

300KVA /240KW

400KVA / 320KW

INPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph + N or 3Ph + N + G)Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 50Hz ±5 Hz (±10%)

OUTPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (Selectable)

Connection Type Hardwire 5-wire (3Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Transient state ±5%

Frequency 50 Hz

Frequency Stability ± 1%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.8

Crest Factor 3:1Total Harmonic Distortion (THDv)

< 2% (Linear Load)< 4% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% (R Load) < ±5% ; 20%->100%->20% (R Load) ±3%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : < 60 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1% (balanced load)120º ±2% (imbalances 50% of the load)

Transfer Time 0 ms

Overload Capability 0% ~ 110% continuous running; 110% ~ 150% for 10 min~1 min; >160% for 200ms

Short-circuit Capability 60~100ms

Transient Response Time < 5ms

BYPASSConnection Type Hardwire 5-wire (3Ph+N+G)

Input Voltage Range 220VAC ± 25%

Overload Capability 1.5 In~1.8 In 1h~30s

Short-circuit Capability 1.8 In ~ >2.0 In 30s~200ms

SYSTEM

(At Linear Load) 90% 90% 91% 91% 91% 91% 92% 92% 92% 92% 92% 92% 93% 93%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 61000-4-5 Protection surge, IEC 62040-2 EMC/EMI, IEC62040-1 Safety

BATTERY & CHARGER

R

Type 6 pulse 6 pulse or 12 pulseRated output voltage 384 VDC

Charger voltage 395VDC ~ 435VDC (Adjustable)Charging current(max) 20A 20A 40A 40A 40A 40A 40A 40A 40A 50A 50A 50A 70A 70A

Battery

Type Support VRLA Battery

Numbers 32 Pcs (29 ~ 32 pcs adjustable)

Reverse Diode No

Cold Start Yes

PHYSICALIP Protection IP20 (Default), IP21/IP31 (Option)Dimensions, D x W x H (mm) 800 x 800 x 1800 800 x 1200 x 1800 800 x 1600 x 1800 850x1630

x1900900x 1700

x 1900Net Weight (Kgs) 350 370 420 450 480 730 790 1000 1300 1400 1700 1900 2300 2500

ENVIRONMENT

Operating Temperature 0~ 35°C continuous running, 40°C 8-hour running at nominal input voltage, recharging batteries and no overload, 45°C derating to 85% with linear load

Humidity 0~90% (non-condensing)

Noise Level Less than 70dB @ 1 Meter Less than 72dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Dry Contacts 6 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

ONLINE UPS

Giant Industrial Series (3P/3P)-TowerPRO633000-EL-480 SERIES 100-600KVA

PROLiNK Giant Industrial Series are three-phase output UPS systems which apply a true online double-conversion technology. Double conversion between input/output, battery and bypass are totally isolated power line noise, spike and transients, keeping power failure away from critical loads. It is designed to deliver clean and high quality electrical power for electrical loads. All Giant Industrial Series UPS systems accept dual-mains inputs.

DSP control technology is implemented for the UPS system to improve performance and high reliability. The front access design makes it easy for users to perform maintenance and replacement activities. The system can have easy integration into existing electrical network or generator. During wiring connection, the unit can be accessed either from top or bottom under different environmental conditions.

The system has robust electrical performance to prevent damage from top and bottom connections and cabinet is using screw-less cabinet design. All internal PCBAs are coated to withstand harsh environment.

PROLiNK Giant Industrial Series has built-in high short circuit protection. Once short circuit occurs, this protection will be activated. The load will stay protected and the UPS will remain intact.

Users can easily monitor and access to their UPS status from a comprehensive LCD display. Potential free dry contacts are provided for UPS alarm monitoring via hard wire. The UPS systems have USB and RS-485 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relay contact cards. SNMP option is also available for power management via SNMP manager and web browser.

Giant Industrial series (480VDC) (3P/3P) series is available in models ranging from 100kVA to 600kVA.

In addition, the system comes with a parallel redundant configuration option that allows four units to operate in parallel.

• True online double conversion with DSP control• Robust electrical performance to prevent damage from top and bottom connections• Screwless cabinet design and fully coating PCBAs to withstand harsh environment • Unique ventilation design for effective heat dissipation• Flexible battery configuration adapts different applications• Accepts dual-mains inputs• Front access makes maintenance and replacement easy• High short-circuit and overload• Easy integration into existing electrical networks or generator• Parallel capability up to 4 units

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 77: PROLINK POWER BACKUP SOLUTION

76

Full Specifications

ONLINE UPS

MODELPRO633100

-EL-480PRO633120

-EL-480PRO633160

-EL-480PRO633200

-EL-480PRO633250

-EL-480PRO633300

-EL-480PRO633400

-EL-480PRO633500

-EL-480PRO633600

-EL-480CAPACITY 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW 250KVA/225KW 300KVA/270KW 400KVA/360KW 500KVA/450KW 600KVA/540KW

INPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph + G)

Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 45Hz ~ 65Hz

OUTPUTNominal Voltage 380VAC/400VAC/415VAC (Selectable)

Connection Type Hardwire 5-wire (3Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Transient state ± 5%

Frequency 50 Hz or 60 Hz (Selectable)

Frequency Stability ± 0.05%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.9

Crest Factor 3:1Total Harmonic Distortion (THDv)

< 1% (Linear Load)< 3% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% load : ≤1%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <20 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1%

Transfer Time 0 ms

Overload Capability 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute, 200% for 7 seconds

Short-circuit Capability 180% for 1 second

Transient Response Time < 10ms

BYPASSConnection Type Hardwire 5-wire (3Ph+N+G)

Input Voltage Range 220VAC ± 15% (setting range ±10% ~ ±25%)

Overload Capability 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute

Short-circuit Capability 1 second (Rated x 7 ), 500 ms (Rated x 8 ), 200 ms (Rated x 9 ), 100 ms (Rated x 10 ), 100 ms (Rated x 14)

SYSTEM93% 93% 93.5% 93.5% 93.5% 93% 93% 93% 93%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 60529, IEC 60664, IEC 60755

BATTERY & CHARGERType IGBTRated output voltage 480 VDC

Charger voltage 524VDC ~ 576VDC (Adjustable) 542VDC ~ 576VDC (Adjustable)Charging current(max) 20A 24A 32A 40A 50A 50A 70A 70A 70A

Battery

Type Support VRLA Battery

Numbers 40 Pcs (40 ~ 43 adjustable)

Reverse Diode No

Cold Start Yes

PHYSICALIP Protection IP20 (Default)

Dimensions, D x W x H(mm) 850 x 800 x 1900 850 x 1000 x 1900 1000 x 1500 x 1900 1000 x 2100 x 1900

Net Weight (Kgs) 656 700 800 910 1000 1400 1700 2100 2400

ENVIRONMENTOperating Temperature 0~ 40°C continuous running, 45°C derating to 85% with linear load

Humidity 0~90% (non-condensing)

Noise Level Less than 65~70dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

Dry Contacts 3 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

Page 78: PROLINK POWER BACKUP SOLUTION

77

Full Specifications

ONLINE UPS

MODELPRO633100

-EL-480PRO633120

-EL-480PRO633160

-EL-480PRO633200

-EL-480PRO633250

-EL-480PRO633300

-EL-480PRO633400

-EL-480PRO633500

-EL-480PRO633600

-EL-480CAPACITY 100KVA/90KW 120KVA/108KW 160KVA/144KW 200KVA/180KW 250KVA/225KW 300KVA/270KW 400KVA/360KW 500KVA/450KW 600KVA/540KW

INPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph + G)

Acceptable Voltage Range 304VAC ~ 456VAC

Frequency 45Hz ~ 65Hz

OUTPUTNominal Voltage 380VAC/400VAC/415VAC (Selectable)

Connection Type Hardwire 5-wire (3Ph+N+G)

Waveform Pure SinewaveOutput Voltage Stability

Steady state ±1%

Transient state ± 5%

Frequency 50 Hz or 60 Hz (Selectable)

Frequency Stability ± 0.05%Frequency Synchronisation Range ± 5Hz (Equal to bypass working range)

Frequency Synchronisation Speed 1~2 Hz/s

Power Factor 0.9

Crest Factor 3:1Total Harmonic Distortion (THDv)

< 1% (Linear Load)< 3% (Non-linear Load)

Dynamic in-rush Voltage Range 0%->100%->0% load : ≤1%

Dynamic Recovery Time (III Grade) 0%~100% RCD load : <20 ms recover to 90% of nominal voltage

Phase Displacement 120º ±1%

Transfer Time 0 ms

Overload Capability 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute, 200% for 7 seconds

Short-circuit Capability 180% for 1 second

Transient Response Time < 10ms

BYPASSConnection Type Hardwire 5-wire (3Ph+N+G)

Input Voltage Range 220VAC ± 15% (setting range ±10% ~ ±25%)

Overload Capability 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute

Short-circuit Capability 1 second (Rated x 7 ), 500 ms (Rated x 8 ), 200 ms (Rated x 9 ), 100 ms (Rated x 10 ), 100 ms (Rated x 14)

SYSTEM93% 93% 93.5% 93.5% 93.5% 93% 93% 93% 93%

ECO Mode (Non-parallel models) Yes

EPO Function Yes

Standard IEC 60529, IEC 60664, IEC 60755

BATTERY & CHARGERType IGBTRated output voltage 480 VDC

Charger voltage 524VDC ~ 576VDC (Adjustable) 542VDC ~ 576VDC (Adjustable)Charging current(max) 20A 24A 32A 40A 50A 50A 70A 70A 70A

Battery

Type Support VRLA Battery

Numbers 40 Pcs (40 ~ 43 adjustable)

Reverse Diode No

Cold Start Yes

PHYSICALIP Protection IP20 (Default)

Dimensions, D x W x H(mm) 850 x 800 x 1900 850 x 1000 x 1900 1000 x 1500 x 1900 1000 x 2100 x 1900

Net Weight (Kgs) 656 700 800 910 1000 1400 1700 2100 2400

ENVIRONMENTOperating Temperature 0~ 40°C continuous running, 45°C derating to 85% with linear load

Humidity 0~90% (non-condensing)

Noise Level Less than 65~70dB @ 1 Meter

MANAGEMENTModbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC

Dry Contacts 3 outputs and 2 inputs

Optional SNMP Power management from SNMP manager and web browser

ONLINE UPS

Sorra Series (3P/1P & 3P/3P)-Rack/TowerPRO53110-QRS / PRO53310-QRS SERIES 10KVA

PROLiNK Sorra Rack/Tower Series- P.F 1.0 UPS systems is designed based on true online double conversion to effectively insulate against network disturbances and enable higher load up time.

PROLiNK Sorra series is applied with patented modular hot-swapping design to enhance the flexibility of power expansion and maintenance. It also simplifies the process of maintenance and replacement to reduce the maintenance cost effectively. DSP technology digitizes the data and mathematically manipulates them to provide an improved solution with higher performance.

PROLiNK Sorra series is designed for easy adjustment, vertical/ horizontal conversion design enhances the flexibility and scalability of the modular UPS. 19” form factor suits the standard rack and optimizes cost expense to meet the power demands.

UPS includes user friendly and easy shift LCD display which shows all information of each power module. It also can be set to display information of whole customized system. SNMP option is also available for power management via SNMP manager and web browser.

The UPS can accept generator as power source and still convert perfect power to the connected loads.

In addition, Emergency Power Off (EPO) function is also available the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

• True double-conversion

• Modular connector box with hot-swappable design for ease of power expansion,

installation and maintenance

• Standard 19” form factor with tower/rack convertible design

• Parallel operation up to 10 UPS modules with common battery

• Adjustable battery design

• DSP technology guarantees high reliability

• Output power factor 1.0

• 50Hz/60Hz frequency converter mode

• ECO mode operation for energy saving

• Emergency power off function (EPO)

• Generator compatible

• Customized system

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

19” RackMount

Local AreaNetwork

(LAN)

Page 79: PROLINK POWER BACKUP SOLUTION

78

Full Specifications

ONLINE UPS

MODEL PRO53310-QRS PRO53110-QRS

PHASE 3 phase in / 3 phase out 3 phase in / 1 phase out

CAPACITY 10000 VA / 10000 W 10000 VA / 10000 W

INPUT

Nominal Voltage 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)

3 x360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)

Voltage Range 190-520 VAC (3-phase) @ 50% load305-478 VAC (3-phase) @ 100% load

190-520 VAC (3-phase) @ 50% load305-478 VAC (3-phase) @ 100% load

Frequency Range 40 Hz ~ 70 Hz

Power Factor ≧ 0.99 @ 100% load

THDi < 4% @ full linear load

OUTPUT

Output Voltage 360VAC/380VAC/400VAC/415VAC (3Ph+N) 208*/220/230/240VAC(L+N)

AC Voltage Regulation (Batt. Mode) ± 1%

Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

Current Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2% THD (Linear Load) ; ≦ 3% THD (Non-linear Load)

≦2% THD (Linear Load) ; ≦ 3% THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode zero

Inverter to Bypass

At Full Load

Peak

zero

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

AC Mode 94% 94%

ECO Mode 97% 97%

BatteryMode 92% 92%

91% 91%

BATTERY CHARGER

Battery Voltage ± 12V / 9 Ah

Battery Numbers 16 ~ 20 pcs (adjustable) x 2 16 ~ 20 pcs (adjustable) x 2

Nominal Voltage +/-192V (12V x 32 pcs) +/-192V (12V x 32 pcs)

Maximum Voltage +/- 240V (12V x 40 pcs) +/- 240V (12V x 40 pcs)

Minimum Voltage +/-192V (12V x 32 pcs) +/-192V (12V x 32 pcs)

Charging Voltage ± 218V ± 218V

Typical Recharging Time 9 hours recover to 90% capacity

Charging Current ± 4A

INDICATORS

LCD/LED Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

PHYSICAL

Dimension, D x W x H(mm) 615 x 418 x 132 [3U]

Net Weight (kgs) 22 22

ENVIRONMENT

Operating Humidity 0-95 % RH @ 0- 40°C (non-condensing)

Noise Level Less than 55dB @ 1 Meter Less than 55dB @ 1 Meter

MANAGEMENT

Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Optional SNMP Power management from SNMP manager and web browser

*Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.

Page 80: PROLINK POWER BACKUP SOLUTION

79

Full Specifications

ONLINE UPS

MODEL PRO53310-QRS PRO53110-QRS

PHASE 3 phase in / 3 phase out 3 phase in / 1 phase out

CAPACITY 10000 VA / 10000 W 10000 VA / 10000 W

INPUT

Nominal Voltage 3 x 360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)

3 x360VAC/380VAC/400VAC/415VAC (3Ph+N+PE)

Voltage Range 190-520 VAC (3-phase) @ 50% load305-478 VAC (3-phase) @ 100% load

190-520 VAC (3-phase) @ 50% load305-478 VAC (3-phase) @ 100% load

Frequency Range 40 Hz ~ 70 Hz

Power Factor ≧ 0.99 @ 100% load

THDi < 4% @ full linear load

OUTPUT

Output Voltage 360VAC/380VAC/400VAC/415VAC (3Ph+N) 208*/220/230/240VAC(L+N)

AC Voltage Regulation (Batt. Mode) ± 1%

Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz

Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz

Current Crest Ratio 3:1 (max.)

Harmonic Distortion ≦2% THD (Linear Load) ; ≦ 3% THD (Non-linear Load)

≦2% THD (Linear Load) ; ≦ 3% THD (Non-linear Load)

Transfer Time

AC Mode to Batt. Mode zero

Inverter to Bypass

At Full Load

Peak

zero

Waveform (Batt. Mode) Pure Sinewave

EFFICIENCY

AC Mode 94% 94%

ECO Mode 97% 97%

BatteryMode 92% 92%

91% 91%

BATTERY CHARGER

Battery Voltage ± 12V / 9 Ah

Battery Numbers 16 ~ 20 pcs (adjustable) x 2 16 ~ 20 pcs (adjustable) x 2

Nominal Voltage +/-192V (12V x 32 pcs) +/-192V (12V x 32 pcs)

Maximum Voltage +/- 240V (12V x 40 pcs) +/- 240V (12V x 40 pcs)

Minimum Voltage +/-192V (12V x 32 pcs) +/-192V (12V x 32 pcs)

Charging Voltage ± 218V ± 218V

Typical Recharging Time 9 hours recover to 90% capacity

Charging Current ± 4A

INDICATORS

LCD/LED Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions

PHYSICAL

Dimension, D x W x H(mm) 615 x 418 x 132 [3U]

Net Weight (kgs) 22 22

ENVIRONMENT

Operating Humidity 0-95 % RH @ 0- 40°C (non-condensing)

Noise Level Less than 55dB @ 1 Meter Less than 55dB @ 1 Meter

MANAGEMENT

Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC

Optional SNMP Power management from SNMP manager and web browser

*Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.

ONLINE UPS

Extend Series (3P/3P)-TowerPROLiNK Extend series UPS system is modular three-phase input / three-phase output online double conversion UPS which takes scalability to a whole new level. Based on a scalable design, the Extend series comes with a range of capacity, from 20kVA to as high as 90kVA.

PROLiNK Extend series is designed with the latest online double conversion technology that provides a high efficiency rating of 94.5% at 50% load. With such a high efficiency rating, the Extend can save hundreds of dollars each year.

The modular design ensures uninterrupted power supply during UPS maintaining and replacing activities. Also, the Extend Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of equipment recovery.

For easy management, the intuitive design of 5.7” graphic LCD display enhances the readability of identified and advanced configuration. Adjustable charging current (6A~8A) feature is provided for each power module.

• High efficiency online double conversion technology

• Output power factor 1

• Modular design lowers MTTR

• Adjustable battery numbers

• Adjustable charging current

• Built-in maintenance bypass switch for easy maintenance without interruption

• Graphic 5.7" LCD design for easy configurationvv

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

Page 81: PROLINK POWER BACKUP SOLUTION

80

Full Specifications

ONLINE UPS

MODEL Extend 15U-60-20HV Extend 15U-90-30HVPHASE 3-phase in/3-phase outMAX CABINET CAPACITY* 60KW 90KWBATTERY TYPE External BatteryONE POWER MODULE CAPACITY 20KVA / 20KW 30KVA / 30KWMAX. POWER MODULE NO. 3INPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N) Voltage Range 305 ~ 478 VAC at 100% load; 208 ~ 478 VAC at <70% loadNominal Frequency 50/60Hz (Auto sensing)Frequency Range 40Hz ~70HzPower Factor > 0.99 at 100% load, >0.98 at 50% loadHarmonic Distortion (THDi) < 3% @ 100% loadOUTPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N)

Voltage Regulation (Steady state) ≦ ± 1% Typical (balanced load) ≦ ± 2% Typical (unbalanced load)

Voltage Regulation (Transient) ≦± 5% Typical Nominal Frequency 50/60HzFrequency Range (Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz Overload Capability 1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150%Harmonic Distortion ≦1.5% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)

Up to 94.5%BATTERY / CHARGERNominal Voltage +/- 216V (12V x 36 Pcs)Maximum Voltage +/- 240V (12V x 40 Pcs)Minimum Voltage +/- 192V (12V x 32 Pcs)Float Charging Voltage 2.25V/CellBoost Charging Voltage 2.35V/CellTemperature Compensation Yes

6A (User-adjustable) 8A (User-adjustable)PHYSICALCabinet Dimension (D x W x H) mm 1000 x 515 x 760Net Weight (kg) 182 183.5ENVIRONMENTOperating Temperature 0 ~ 40°CRelative Humidity 0 ~ 95% non-condensingAltitude <1000m for Nominal powerIP Class IP 20MANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browserSTANDARDSSafety IEC/EN 60950-1; IEC/EN 62040-1EMC IEC/EN 62040-2 Category C3

*When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃. **If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.

Maximum Charging Current

Page 82: PROLINK POWER BACKUP SOLUTION

81

Full Specifications

ONLINE UPS

MODEL Extend 15U-60-20HV Extend 15U-90-30HVPHASE 3-phase in/3-phase outMAX CABINET CAPACITY* 60KW 90KWBATTERY TYPE External BatteryONE POWER MODULE CAPACITY 20KVA / 20KW 30KVA / 30KWMAX. POWER MODULE NO. 3INPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N) Voltage Range 305 ~ 478 VAC at 100% load; 208 ~ 478 VAC at <70% loadNominal Frequency 50/60Hz (Auto sensing)Frequency Range 40Hz ~70HzPower Factor > 0.99 at 100% load, >0.98 at 50% loadHarmonic Distortion (THDi) < 3% @ 100% loadOUTPUTNominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N)

Voltage Regulation (Steady state) ≦ ± 1% Typical (balanced load) ≦ ± 2% Typical (unbalanced load)

Voltage Regulation (Transient) ≦± 5% Typical Nominal Frequency 50/60HzFrequency Range (Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz Overload Capability 1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150%Harmonic Distortion ≦1.5% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)

Up to 94.5%BATTERY / CHARGERNominal Voltage +/- 216V (12V x 36 Pcs)Maximum Voltage +/- 240V (12V x 40 Pcs)Minimum Voltage +/- 192V (12V x 32 Pcs)Float Charging Voltage 2.25V/CellBoost Charging Voltage 2.35V/CellTemperature Compensation Yes

6A (User-adjustable) 8A (User-adjustable)PHYSICALCabinet Dimension (D x W x H) mm 1000 x 515 x 760Net Weight (kg) 182 183.5ENVIRONMENTOperating Temperature 0 ~ 40°CRelative Humidity 0 ~ 95% non-condensingAltitude <1000m for Nominal powerIP Class IP 20MANAGEMENTSmart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MACOptional SNMP Power management from SNMP manager and web browserSTANDARDSSafety IEC/EN 60950-1; IEC/EN 62040-1EMC IEC/EN 62040-2 Category C3

*When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃. **If the UPS is installed or used in a placewhere the altitude is above than 1000m, the output power must be derated one percent per 100m.

Maximum Charging Current

ONLINE UPS

Titan Series (3P/3P)-Tower

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

DataCentre

PROLiNK Titan Series is modular three-phase input / three-phase output online double conversion UPS takes

scalability to a whole new level. Based on a scalable design, the Titan comes with a wide range of capacity, ranging

from as low as 20kVA to as high as 300kVA. The Titan series is designed with a N+X parallel redundancy system that

allows two or more UPS modules to operate in parallel and as back-up for each other.

This unit provides an ideal protection for data centres, telecommunication facilities and other critical applications. Up

to ten 30kVA modules can be fitted into a standard cabinet to simplify maintenance and replacement activities. The

Series guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair

and the point of equipment recovery. Some distinct features of the PROLiNK Titan series are as listed below.

Page 83: PROLINK POWER BACKUP SOLUTION

82

High Efficiency Online Double Conversion TechnologyPROLiNK Titan series is designed with the latest online double conversion technology that provides a high efficiency rating of

94.5% at 50% load. With such a high efficiency rating, the Titan can save hundreds of dollars each year.

High ScalabilityBased on a scalable design, the Titan Series simplifies future expansion by making UPS units easily upgradable. This architecture

allows you to meet power demands by adding additional modules vertically in a single rack enclosure.

Unity Output Power FactorWith a unity output factor (kVA = kW), the PROLiNK Titan UPS system is 100% compatible with today's high power factor loads. It

is able to meet the latest server requirements, giving the best value for your IT investments.

Modular Design Lowers MTTRThe modular design ensures uninterrupted power supply during UPS maintaining and replacing activities. Also, the Titan Series

guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of

equipment recovery.

N+1 and N+X Parallel Redundancy for power guaranteePROLiNK Titan series is designed with scalable architecture which allows user to optimise cost expense to meet power demands

by vertically expanding in a single rack enclosure from 30KVA to 300KVA and achieve N+1 or N+X redundancy in the same rack.

Ease Of Installation and MaintenanceWith a built-in maintenance bypass feature, the UPS is able to deliver continuous power to the

critical load during maintenance. Better yet, the Titan comes with a front access concept to facilitate

installation.

Flexible Battery configuration adapts different applicationsBattery numbers can be adjusted flexibly. It will adapt different power demands and shorten system

downtime. Battery voltage can be set from 32 to 40 pieces per string.

Highly reliable operation with redundant power supply in STSPROLiNK Titan series provides 2 power supplies in STS, ensuring no risks of shut down.

User adjustable charging currentPROLiNK Titan series provides maximum 8A or 6A charging current for every power module and its

user adjustable requirement.

High Overload CapabilityPROLiNK Titan series supports 110 % overload for 60 mins, 125% for 10 mins and 150% for 1 min.

Graphic 5.7” LCD for easy managementFor easy management, the intuitive design of 5.7” graphic LCD display enhances the readability of

identified and advanced configuration. Optional 10” touch LCD panel is available for the system.

ONLINE UPS

Page 84: PROLINK POWER BACKUP SOLUTION

83

High Efficiency Online Double Conversion TechnologyPROLiNK Titan series is designed with the latest online double conversion technology that provides a high efficiency rating of

94.5% at 50% load. With such a high efficiency rating, the Titan can save hundreds of dollars each year.

High ScalabilityBased on a scalable design, the Titan Series simplifies future expansion by making UPS units easily upgradable. This architecture

allows you to meet power demands by adding additional modules vertically in a single rack enclosure.

Unity Output Power FactorWith a unity output factor (kVA = kW), the PROLiNK Titan UPS system is 100% compatible with today's high power factor loads. It

is able to meet the latest server requirements, giving the best value for your IT investments.

Modular Design Lowers MTTRThe modular design ensures uninterrupted power supply during UPS maintaining and replacing activities. Also, the Titan Series

guarantees a low mean-time-to-repair (MTTR), giving users a shorter elapsed time between the point of repair and the point of

equipment recovery.

N+1 and N+X Parallel Redundancy for power guaranteePROLiNK Titan series is designed with scalable architecture which allows user to optimise cost expense to meet power demands

by vertically expanding in a single rack enclosure from 30KVA to 300KVA and achieve N+1 or N+X redundancy in the same rack.

Ease Of Installation and MaintenanceWith a built-in maintenance bypass feature, the UPS is able to deliver continuous power to the

critical load during maintenance. Better yet, the Titan comes with a front access concept to facilitate

installation.

Flexible Battery configuration adapts different applicationsBattery numbers can be adjusted flexibly. It will adapt different power demands and shorten system

downtime. Battery voltage can be set from 32 to 40 pieces per string.

Highly reliable operation with redundant power supply in STSPROLiNK Titan series provides 2 power supplies in STS, ensuring no risks of shut down.

User adjustable charging currentPROLiNK Titan series provides maximum 8A or 6A charging current for every power module and its

user adjustable requirement.

High Overload CapabilityPROLiNK Titan series supports 110 % overload for 60 mins, 125% for 10 mins and 150% for 1 min.

Graphic 5.7” LCD for easy managementFor easy management, the intuitive design of 5.7” graphic LCD display enhances the readability of

identified and advanced configuration. Optional 10” touch LCD panel is available for the system.

ONLINE UPS

Full Specifications

ONLINE UPS

MODEL Titan 30U-90-30HV Titan 42U-120-30HV Titan 30U-120-30HVTitan 30U-80-20HV

Titan 30U-180-30HVTitan 30U-120-20HV Titan 42U-200-20HV Titan 42U-210-30HV Titan 42U-300-30HV

PHASE 3-phase in / 3-phase out

CABINET CAPACITY* 90 KW 120 KW 120 KW or 80 KW 180 KW or 120 KW 200 KW 210 KW 300 KW

BATTERY TYPE Built-in Battery External Battery

ONE POWER MODULE CAPACITY 30KVA / 30KW 30KVA / 30KW or 20KVA / 20KW 20KW 30KVA / 30KW 30KVA / 30KW

MAX. POWER MODULE NO. 3 4 4 6 10 8 10

MAX. BATTERY SET NO.** 3 5 - - - - -

INPUT

Nominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N)

Voltage Range 305 ~ 478 VAC at 100% load; 208 ~ 304VAC at <70% load

Nominal Frequency 50/60Hz (Auto Sensing)

Frequency Range 40Hz ~70Hz

Power Factor > 0.99 @ 100% Load , >0.98 @ 50% Load

Harmonic Distortion (THDi) < 3% @ 100% load

OUTPUT

Nominal Voltage 3 x 380VAC/400VAC/415VAC (3Ph+N)

Voltage Regulation(Steady state) ≦± 1% Typical (balanced load) ; ≦ ± 2% Typical (imbalanced load)

Nominal Frequency 50/60Hz

Frequency Range(Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz

Overload Capability 1 hour for 110%, 10 mins for 125%,; 1 min for 150%, 200ms for >150%

Harmonic Distortion ≦ 2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load)

Up to 94.5%

BATTERY / CHARGER

Nominal Voltage +/- 216V (12V x 36 pcs)

Maximum Voltage +/- 240V (12V x 40 pcs)

Minimum Voltage +/- 192V (12V x 32 pcs)

Float Charging Voltage 2.25V / Cell

Boost Charging Voltage 2.35V / Cell

Temperature Compensation Yes

Maximum Charging Current (Per Power Module) 8A 8A for 30KW power module

6A for 20KW power module 6A 8A

PHYSICAL

Cabinet Dimension (DxWxH) mm 1100 x 600 x 1475 1100 x 600 x 2010 1100 x 600 x 1475 1100 x 600 x 1475 1100 x 600 x 2010

Net Weight (Kg) 675 932 335 or 333 437.5 or 434.5 611 549 620

ENVIRONMENT

Operating Temperature 0 ~ 40°C

Relative Humidity 0 ~ 95% non-condensing

Altitude <1000m for Nominal power

IP Class IP 20

MANAGEMENT

Smart RS-232 / USB Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux and MAC

Optional SNMP Power management from SNMP manager and web browser

STANDARDS

Safety IEC/EN 60950-1; IEC/EN 62040-1

EMC IEC/EN 62040-2 Category C3

*When temperature is above 30℃, the output power factor will be de-rated, 0.9 at 31℃~35℃ and 0.8 at 36℃~40℃. ** One battery module contains 10 pcs of 12V/7Ah or 12/9Ah sealed lead acid batteries in one tray. One complete battery set contains 4 battery modules.***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.

Efficiency

Page 85: PROLINK POWER BACKUP SOLUTION

84

ONLINE UPS

PRO-R Series

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

PRO-R Series is transformer-less design with slim 1U form factor, perfect to fit for data processing and transmission such as servers, networking and IP telephone services. Despite its truly compact size, just 44 mm, it offers the same intelligent performance as any other online UPS.

With true double-conversion technology, it provides clean, high level quality power to fully protect mission-critical devices. With Built-in master and slave output segments, PRO-R series UPS will automatically shut down the power to two slave output receptacles when the master device is no longer drawing current. Besides, it is designed with easy-replaceable battery design to simplify battery replacement within few minutes and shorten system downtime.

In addition, Emergency Power Off (EPO) function is also available the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

1

187

4

6

2 3 5 4 6

2

9

9PRO1000RL

PRO1000RS

Rear Panel

1. AC input2. Output receptacle: connect to mission-critical loads3. Programmable outlets: connect to non-critical loads4. USB/RS-232 serial communication port 5. ROO/RPO function connector

6. SNMP intelligent slot 7. Dry contact8. External battery connector9. Cooling fan

1KVA

PRO1000RS/RL SERIES

Page 86: PROLINK POWER BACKUP SOLUTION

85

ONLINE UPS

PRO-R Series

DataCentre

Electro-MedicalDevice

StoragePLCS

EmergencyAlarm

Devices

E-Business(Server Farms, ISP/ASP/POP)

TelecommunicationDevices

Local AreaNetwork

(LAN)

PRO-R Series is transformer-less design with slim 1U form factor, perfect to fit for data processing and transmission such as servers, networking and IP telephone services. Despite its truly compact size, just 44 mm, it offers the same intelligent performance as any other online UPS.

With true double-conversion technology, it provides clean, high level quality power to fully protect mission-critical devices. With Built-in master and slave output segments, PRO-R series UPS will automatically shut down the power to two slave output receptacles when the master device is no longer drawing current. Besides, it is designed with easy-replaceable battery design to simplify battery replacement within few minutes and shorten system downtime.

In addition, Emergency Power Off (EPO) function is also available the UPS models and which is used to protect the personnel and the equipment in case of fire outbreak or other types of emergency.

1

187

4

6

2 3 5 4 6

2

9

9PRO1000RL

PRO1000RS

Rear Panel

1. AC input2. Output receptacle: connect to mission-critical loads3. Programmable outlets: connect to non-critical loads4. USB/RS-232 serial communication port 5. ROO/RPO function connector

6. SNMP intelligent slot 7. Dry contact8. External battery connector9. Cooling fan

1KVA

PRO1000RS/RL SERIES

ONLINE UPS

Full Specifications

MODEL PRO1000RS PRO1000RL

CAPACITY

INPUT

Voltage Range

Low Line Transfer

Low Line Comeback

High Line Transfer

High Line Comeback

Frequency Range

Phase

Power Factor

OUTPUT

EFFICIENCY

BATTERY

PHYSICAL

ENVIRONMENT

MANAGEMENT

Output voltage

AC Voltage Regulation

Frequency Range (Synchronized Range)

Frequency Range (Bat. Mode)

Overload

Current Crest Ratio

Harmonic Distortion

Transfer Time Inverter to Bypass

AC Mode to Bat Mode

Waveform (Bat Mode)

AC Mode

Battery Mode

Battery Type

Numbers

Recharge Time

Dimension, D X W X H (mm)

Net Weight (kg)

Operation Humidity

Noise Level

USB/RS-232

Optional SNMP

*1KL is only available in 220/230/240VAC system.

1000 VA / 800 W

150 VAC ± 5 % or 300 VAC ± 5 %

140 VAC ± 5 % or 290 VAC ± 5 %

40Hz ~ 70 Hz

Single phase with ground

≧ 0.99 @ Nominal voltage (full load)

110/120 VAC or 220/230/240 VAC

± 1%

57 ~ 63 Hz or 47 ~ 53 Hz

60Hz or 50 Hz± 0.3 Hz

80VAC/70VAC/60VAC/55VAC ± 5 % or 160VAC/140VAC/120VAC/110VAC ± 5 %( based on load percentage 100% -80 % / 80 % -70 % / 70 -60 % / 60 % -0)

85VAC/75VAC/65VAC/60VAC ± 5 % or 170VAC/150VAC/130VAC/120VAC ± 5 %( based on load percentage 100% -80 % / 80 % -70 % / 70 -60 % / 60 % -0)

100%~105%: audible warning 105%-130%: UPS shuts down in 10 seconds at battery mode or transfers to bypass mode after 2min when the utility is normal.

>130%: UPS shuts down immediately at battery mode or transfer to bypass mode after 10s when the utility is normal.

5:1 for 110/120 VAC system or 3:1 for 220/230/240 VAC systems

≦3 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)

Zero

4 ms (Typical)

Pure Sinewave

~ 86% @ 100% load

~ 83% @ 100% load

6 V / 9 AH

4 Lithium-iron battery or Sealed Lead-acid battery (Battery voltage: 48VDC)

9 hours recover to 90% capacity

477 x 438 x 44

12.6

20-90 % RH @ 0-50°C (non-condensing)

20-90 % RH @ 0-55°C (non-condensing)

300 x 438 x 44

Less than 50dBA @ 1 Meter

Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC

Power management from SNMP manager and web browser

6

Page 87: PROLINK POWER BACKUP SOLUTION

86

Super Fast Charging Line Interactive Series

LINE INTERACTIVE UPS

PROLiNK SFC series is a single-phase input/ single-phase

output Line-Interactive UPS system with PROLiNK’s latest

Super-Fast Charging technology. This cutting-edge technology

is able to recharge the battery back to 90% of its capacity within

2-4 hours, and is ideal for providing stable backup power to

home/ small office applications. A wide input voltage range is

supported due to the integrated 3-Step AVR which features 2

boosts and 1 buck to regulate output voltage. This prevents

under voltage brownouts and over voltage surges. The unit also

comes with universal sockets to provide better compatibility

with a wider range of devices.

PRO SFC SERIES 650VA-2000VA

• Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours

• Excellent microprocessor control guarantees high reliability

• Boost and buck AVR for voltage stabilization

• Auto restart while AC is recovering

• Simulated sine wave

• Off-mode charging

• Cold start function

• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection

PC Printer Work-Stations

Page 88: PROLINK POWER BACKUP SOLUTION

87

Super Fast Charging Line Interactive Series

LINE INTERACTIVE UPS

PROLiNK SFC series is a single-phase input/ single-phase

output Line-Interactive UPS system with PROLiNK’s latest

Super-Fast Charging technology. This cutting-edge technology

is able to recharge the battery back to 90% of its capacity within

2-4 hours, and is ideal for providing stable backup power to

home/ small office applications. A wide input voltage range is

supported due to the integrated 3-Step AVR which features 2

boosts and 1 buck to regulate output voltage. This prevents

under voltage brownouts and over voltage surges. The unit also

comes with universal sockets to provide better compatibility

with a wider range of devices.

PRO SFC SERIES 650VA-2000VA

• Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours

• Excellent microprocessor control guarantees high reliability

• Boost and buck AVR for voltage stabilization

• Auto restart while AC is recovering

• Simulated sine wave

• Off-mode charging

• Cold start function

• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection

PC Printer Work-Stations

LINE INTERACTIVE UPS

Rear Panel

1. AC input

2. Backup Output

3. Bypass Output (without battery back up)

4. USB Port (Only available in SFCU series)

5. RJ11

6. Cooling Fan

650-2000VA

1 11

1

4

3

4 44

5

5

2 2

2

32

5

PRO700SFC/ SFCU PRO851SFCU PRO1201SFC/ SFCU

PRO1501SFC/SFCU PRO2000SFC/SFCU

6

Page 89: PROLINK POWER BACKUP SOLUTION

88

Full Specifications

LINE INTERACTIVE UPS

MODEL

CAPACITY

INPUT

Nominal Voltage

Voltage Range

Nominal Frequency

OUTPUT

Output Voltage Regulation (Battery Mode)

Frequency

Transfer Time (Typical)

Waveform

BATTERY

Number of Battery

Recharge Time (Typical)

PROTECTION

Full Protection

INDICATION

LED Display

ALARM

Sounding

PHYSICAL

Dimension (mm) D x W x H

Net Weight (kgs)

ENVIRONMENT

Humidity

Noise Level

MANAGEMENT

USB/RS-232

230VAC

140 - 300 VAC ± 5%

50 or 60Hz (Auto sensing)

± 10%

50 or 60Hz ± 1Hz

2 - 6m

Simulated Sinewave

650VA 850VA 1200VA

12 V/8.2 Ah x 1 12 V/10 Ah x 1 12 V/8.2 Ah x 2 12 V/10 Ah x 2

4-6 hours recover to 90% capacity

1500VA 2000VA

PRO700SFC/SFCU PRO851SFC/SFCU PRO1201SFC/SFCU PRO1501SFC/SFCU PRO2000SFC/SFCU

2-4 hours recover to 90% capacity

Short Circuit, Overload, Discharge and Overcharge Protection

AC Mode - Green Lighting

Battery Mode - Yellow Flashing every 10 seconds

Overload - Red Flashing every second

Fault - Red Lighting

Battery Mode - Sounding every 10 seconds

Low Battery - Sounding every second

Overload - Souding every 0.5 seconds

Battery Replacement Alram - Sounding every 2 seconds

Fault - Continously sounding

0-90 % RH @ 0- 40°C (Non-condensing)

Less than 40dB

Support Windows® 2003/XP/Vista/2008/7/8/10, Linux and Mac

279 x 101 x 142

4.2 4.9 8.2 10.4 10.6

320 x 130 x 182

Product specifications are subject to change without further notice.

Page 90: PROLINK POWER BACKUP SOLUTION

89

Super Fast ChargingLine Interactive Series

LINE INTERACTIVE UPS

The PRO SFT series is a single-phase input/ single-phase

output Line-Interactive UPS system with PROLiNK's latest

Super-Fast Charging technology. It allows for the battery to be

recharged back to 90% of its capacity within 2-4 hours, and is

ideal for providing stable backup power to home/ small office

applications.

A wide input voltage range is supported due to the integrated

3-Step AVR which features 2 boosts and 1 buck to regulate

output voltage. This helps prevent under voltage brownouts and

over voltage surges. The unit also comes with a LCD user interface

that provides valuable information such as output voltage, input

voltage, load level, battery voltage and overload warning

signals.

PRO SFT SERIES 650VA-2000VA

• Built-in super fast charger, battery can be recharged to 90% of its capacity within 2-4 hours

• Excellent microprocessor control guarantees high reliability

• Boost and buck AVR for voltage stabilization

• Auto restart while AC is recovering

• Simulated sine wave

• Off-mode charging

• Cold start function

• Optional USB/RS-232 communication port and RJ-11/RJ-45 protection

PC Printer Work-Stations

Page 91: PROLINK POWER BACKUP SOLUTION

90

LINE INTERACTIVE UPS

Rear Panel

1. AC Input2. Backup Outlet3. Bypass Outlet (without battery back up) 4. USB Port (only available in SFTU models) 5. RJ11 Ports6. Cooling Fan

650-2000VA

PRO700SFT/SFTU PRO850SFTU PRO1201SFT/SFTU

1

1

4

4

4

5

22 2

1

3

5

1

4

32

5

PRO1501SFT/SFTUPRO2000SFT/SFTU

6

Page 92: PROLINK POWER BACKUP SOLUTION

91

Full Specifications

LINE INTERACTIVE UPS

MODEL

CAPACITY

INPUT

Nominal Voltage

Voltage Range

Nominal Frequency

OUTPUT

Output Voltage Regulation (Battery Mode)

Frequency

Transfer Time (Typical)

Waveform

BATTERY

Number of Battery

Recharge Time (Typical)

PROTECTION

Full Protection

INDICATION

LCD Display

ALARM

Sounding

PHYSICAL

Dimension (mm) D x W x H

Net Weight (kgs)

ENVIRONMENT

Humidity

Noise Level

MANAGEMENT

USB/RS-232

230VAC

140 - 300 VAC ± 5%

50 or 60Hz (Auto sensing)

± 10%

50 or 60Hz ± 1Hz

2 - 6m

Simulated Sinewave

650VA 850VA 1200VA

12 V/8.2 Ah x 1 12 V/10 Ah x 1 12 V/8.2 Ah x 2 12 V/10 Ah x 2

4-6 hours recover to 90% capacity

1500VA 2000VA

PRO700SFT/SFTU PRO851SFT/SFTU PRO1201SFT/SFTU PRO1501SFT/SFTU PRO2000SFT/SFTU

2-4 hours recover to 90% capacity

Short Circuit, Overload, Discharge and Overcharge Protection

Battery Mode - Sounding every 10 seconds

Low Battery - Sounding every second

Overload - Souding every 0.5 seconds

Battery Replacement Alram - Sounding every 2 seconds

Fault - Continously sounding

0-90 % RH @ 0- 40°C (Non-condensing)

Less than 40dB

Support Windows® 2003/XP/Vista/2008/7/8/10, Linux and Mac

300 x 101 x 142

4.2 4.9 8.2 10.4 10.6

320 x 130 x 182

Product specifications are subject to change without further notice.

Page 93: PROLINK POWER BACKUP SOLUTION

92

Line Interactive Series

LINE INTERACTIVE UPS

PRO-L Series is a single-phase input / single-phase output

line-interactive UPS system that provides clean and reliable

back-up power for longer periods of time. It is able to provide

clean electrical power and is ideal for home / small office a

pplications. A wide input voltage range is supported due to the

integrated 3-Step AVR which features 2 boosts and 1 buck to

regulate output voltage. High voltage battery chargers and

battery extension assembly are made available for longer

runtime applications. The PRO-L Series with capacities of up to

850VA also comes with universal sockets to provide better

compatibility with a wider range of devices.

PRO-L Series 600VA-2000VA

• Excellent microprocessor control guarantees high reliability

• Boost and buck AVR for voltage stabilization

• Adjustable battery charging current

• Auto restart while AC is recovering

• Off-mode charging

• Cold start function

• Simulated sine wave

PC Printer Work-Stations

Page 94: PROLINK POWER BACKUP SOLUTION

93

LINE INTERACTIVE UPS

Rear Panel

1. AC input2. Input protection3. Output outlet4. Battery Connection5. Fan

600-2000VA

4

1

5

2

3

4

1

5

2

3

PRO700L/PRO1000L PRO2000L

Page 95: PROLINK POWER BACKUP SOLUTION

94

Full Specifications

LINE INTERACTIVE UPS

MODEL PRO700L PRO1000L PRO2000L

CAPACITY 600 VA / 360 W 1000 VA / 600 W 2000 VA / 1200 W

INPUT

Voltage 220/230 VAC

Acceptable Voltage Range 140 - 300 VAC

Frequency Range 50Hz

OUTPUT

AC Voltage Regulation (Batt. Mode) 220/230 ± 10%

Frequency Range (Batt. Mode) 50 Hz ±1 Hz

Transfer Time Typical 4-8 ms

Waveform (Batt. Mode) Simulated Sinewave

BATTERY

Battery Voltage 12 VDC 24 VDC

Floating Charging Voltage 13.7 VDC ± 2% 27.4 VDC ± 2%

Maximum Charge Current 2.5A/6A/10A (Adjustable from manufacturer)

5A/10A/15A/20A (Adjustable from manufacturer)

PROTECTION

Full Protection Overload, discharge, and overcharge protection

INDICATORS

Line Mode Green lighting

Battery Mode

Fault Red lighting

ALARM

Low Battery Sounding every second

Overload Sounding every 0.5 second

Battery Replacement Alarm Sounding every 2 seconds

Fault Continuously sounding

PHYSICAL

Dimension, D x W x H (mm) 358.5 x 96.8 x 146.5 395 x 145 x 220

Net Weight (kgs) 5.8 9.0 13.55

ENVIRONMENT

Humidity 0 to 90% Relative Humidity (Non-condensing)

Noise Level Less than 40dB

Yellow flashing

Product specifications are subject to change without further notice.

Page 96: PROLINK POWER BACKUP SOLUTION

95

Full Specifications

LINE INTERACTIVE UPS

MODEL PRO700L PRO1000L PRO2000L

CAPACITY 600 VA / 360 W 1000 VA / 600 W 2000 VA / 1200 W

INPUT

Voltage 220/230 VAC

Acceptable Voltage Range 140 - 300 VAC

Frequency Range 50Hz

OUTPUT

AC Voltage Regulation (Batt. Mode) 220/230 ± 10%

Frequency Range (Batt. Mode) 50 Hz ±1 Hz

Transfer Time Typical 4-8 ms

Waveform (Batt. Mode) Simulated Sinewave

BATTERY

Battery Voltage 12 VDC 24 VDC

Floating Charging Voltage 13.7 VDC ± 2% 27.4 VDC ± 2%

Maximum Charge Current 2.5A/6A/10A (Adjustable from manufacturer)

5A/10A/15A/20A (Adjustable from manufacturer)

PROTECTION

Full Protection Overload, discharge, and overcharge protection

INDICATORS

Line Mode Green lighting

Battery Mode

Fault Red lighting

ALARM

Low Battery Sounding every second

Overload Sounding every 0.5 second

Battery Replacement Alarm Sounding every 2 seconds

Fault Continuously sounding

PHYSICAL

Dimension, D x W x H (mm) 358.5 x 96.8 x 146.5 395 x 145 x 220

Net Weight (kgs) 5.8 9.0 13.55

ENVIRONMENT

Humidity 0 to 90% Relative Humidity (Non-condensing)

Noise Level Less than 40dB

Yellow flashing

Product specifications are subject to change without further notice.

Outdoor Line Interactive Series

LINE INTERACTIVE UPS

The PROLiNK® PRO2000LD is a single-phase input/ single-phase output Outdoor UPS system. A wide operating temperature range of -40°C to 80°C makes it ideal for outdoor usage. Designed to put up the best performance under the harshest environment, the PRO2000LD is able to supply continuous power to critical loads during a blackout or power outage.

Equipped with dry contacts, the PRO2000LD is able to program safety-oriented signals to meet the requirements of different applications. As such, users are able to monitor UPS events that are most concerned to them. The PRO2000LD comes in a capacity of 2000VA.

PRO2000LD (2000VA)

• Provide continuous power to critical loads during blackout in rugged environment

• Wide operating temperature range from -40°C to 80°C suits for outdoor applications

• Built-in boost and buck AVR to regulate input voltage

• Selectable transfer time for normal or generator modes

• Provide RS-232, USB and SNMP intelligent port

• Circuit breaker protection on AC input, AC output and external battery input

• User-adjustable charging current

• Adjustable input threshold voltage

• Provide programmable signals for dry contacts

• Battery compensation optimizes battery lifecycle

PC CCTV Traffic LightControl System

Work-Stations

Page 97: PROLINK POWER BACKUP SOLUTION

96

LINE INTERACTIVE UPS

Rear Panel

1. AC input terminal block

2. AC input breaker

3. AC output terminal block

4. AC output breaker

5. Input contact

6. Dry contact

7. Internal fan

8. GND

9. Battery connector

10. Battery temperature sensor

11. External FAN connector

12. PTS control connector

13. Battery breaker

14. Battery voltage test points

15. Function keys

16. Liquid Crystal Display (LCD)

17. Indicator LEDs

18. USB connector

19. RS232 connector

20. Intelligent slot

2000VA

PRO2000LD

20

1 3 5 6 7 8 9

14151641819 2 17 1210 11

13

Page 98: PROLINK POWER BACKUP SOLUTION

97

Full Specifications

LINE INTERACTIVE UPS

MODEL PRO2000LD

Rated Power 2000VA / 1600W

INPUT

Nominal Voltage 120 VAC or 230 VAC

Acceptable Voltage Range 100-130 VAC (Default) or 170-300 VAC88-152 VAC (AVR Function enabled only available for 120VAC system, adjustable)

Frequency Range 50 Hz/60 Hz (Auto sensing)

OUTPUT

Nominal Voltage 120 VAC or 230 VAC

Voltage Regulation (Batt. Mode) 120 VAC ± 5% or 230 VAC ± 5%

Output Frequency 50Hz/60Hz ± 0.1%

THD (Batt. Mode) <3% @ Full resistive load

AC Mode 95%

AVR Mode 90%

Battery Mode 87% - 90%

Transfer Time Normal Mode (max.) 12ms

Generator Mode (max.) 25ms

Waveform Pure sinewave

BATTERY

Nominal DC Voltage 48VDC

Low DC Warning Voltage 46VDC ± 0.4VDC @ no load

Battery Type AGM/Gel

Charging Current 2A/4A/6A/8A/10A (Adjustable)

INDICATORS

Bypass Mode Green LED on

Battery Mode

No Output Green LED off

Warning with Output Yellow LED on

Fault without Output Red LED on

MANAGEMENT

Communication RS-232/USB and SNMP

Dry Contact Rating 3A @ 125VAC or 250VAC

PHYSICAL

Dimension, Dx W x H (mm) 400 x 240 x 133

Net Weight (kgs) 12.5

Type of Mechanical Protection IP20

ENVIRONMENT

Humidity 5% to 95% Relative Humidity(Non-condensing)

Operating Temperature -40℃ to 80℃

Noise Level < 48dB

COMPLIANCE

EMI Compliance Class A FCC/CISPR [EN50091-2: 1995]

Surge Protection IEEE/ANSI C.62.41 & 2KV, L-N

Green LED flashing

Efficiency

Page 99: PROLINK POWER BACKUP SOLUTION

98

Simulated Sinewave Inverter Series

INVERTER

PROLiNK IPS Series is a compact home inverter system that delivers high efficiency conversion from DC to AC power. This economically ideal system provides clean and stable power for home appliances and generator related devices. In cases where the electrical utility is down, the home inverter system is able to draw DC current from the battery and supply power to all the AC loads connected to it. Covering a wide selection of sizes, the IPS Series is available in capacities as low as 1200VA to as high as 2400VA.

IPS Series 1.2KVA-2.4KVA

• Selectable Voltage Range

• Advanced Protection

• Auto restart while AC is recovering

• LCD and/or LED panel (Refer to the specifications)

Rear Panel

1. Output receptacles

2. Operation mode selector

4. AC input

5. Input breaker

6. External battery connectors

7. Solar panel terminal (option)

8. Solar charging indicator connection (option)

1200-2400VA2 4

57

6

6

8

2 4

578IPS2400

IPS1200

1

Page 100: PROLINK POWER BACKUP SOLUTION

99

Full Specifications

INVERTER

Nominal Voltage

Voltage Range

Capacity

Battery VoltageFloating Charge Voltage

INPUT

MODELS

Frequency Range

BATTERY

ENVIRONMENT

PHYSICAL

ALARM

INDICATORS

PROTECTION

LED Display

LCD Display

Shutdown VoltageOvercharge Protection

Maximum Charge Current

Full Protection

AC Voltage Regulation (Batt. Mode)

Transfer Time

Waveform (Batt. Mode)Peak Efficiency

Low Battery Alarm Voltage

FaultLine Mode

Battery ModeLow Battery

Shutdown ModeCharging ModeOverload

Low BatteryOverloadFault

Battery Replacement

Overload and short circuit protection

OUTPUT

0 to 90% Relative Humidity (Non-condensing)HumidityOperating TemperatureStorage Temperature

Dimension (mm) D x W × HNet Weight (kgs)

170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)

50/60 Hz (Auto Sensing)

220/ 230/ 240 VAC

13.7 VDC ± 0.25 VDCNot Applicable

Not Applicable

1200VAIPS1200

230VAC ± 10%

10 ms (Typical) 20 ms (max)

>95%Simulated Sinewave

10A or 20A (Selectable)

15 VDC

Input Voltage, Output Voltage,Load level, Battery level and Fault alarm

Not Applicable

Yellow FlashingYellow Flashing

Yellow Flashing

Green FlashingRed Flashing

Red Lighting

Sounding every 2 secondsSounding every 0.5 second

Continuously sounding

Not Applicable

293 x 231.5 xx 82.5

0°C to 40°CNot Applicable

2.35

170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)

220/ 230/ 240 VAC

2400VA

24 VDC

IPS2400

230VAC ± 10%

10 ms (Typical) 20 ms (max)

>95%

27.4 VDC ± 0.5 VDCNot Applicable

Not Applicable30 VDC

10A or 20A (Selectable)

Input Voltage, Output Voltage,Load level, Battery level and Fault alarm

Not Applicable

Yellow FlashingYellow Flashing

Yellow Flashing

Green FlashingRed Flashing

Red Lighting

Sounding every 2 seconds

Not Applicable

293 x 231.5 xx 82.5

Not Applicable

2.55

Page 101: PROLINK POWER BACKUP SOLUTION

100

Pure Sinewave Inverter Series

INVERTER

IPS Series 2KVA-3KVA

• Pure sine wave inverter • Isolation design between input and output for safety guarantee • Lightweight, stainless steel, and anodised aluminium casing • Low power consumption for energy saving • Over-temperature, DC reverse polarity and short circuit protection • Low/High battery alarm and protection

Rear Panel

1. LCD display2. Status indicator3. Fault indicator4. Function buttons5. Power on/off switch6. Battery input 7. AC output8. Communication port9. Remote on/off control port10. GND Terminal11. Cooling fans

2000-3000VA

DC/AC inverter without charger

AC/DC

External Battery pack

BATTERYBATTERYBATTERYDC Input

AC Output

Appliances

This inverter can offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation based on different applications.

6

5 78

9

10

1

2 3

4

11

Page 102: PROLINK POWER BACKUP SOLUTION

101

Full Specifications

INVERTER

MODEL IPS2000 IPS3002

Rated Power 2000VA/1600W 3000VA/2400W

INPUT

Nominal DC Voltage 24 VDC

Cold Start Voltage 23 VDC

Acceptable Voltage Range 21 VDC ~ 29 VDC

Low DC Warning Voltage@ load <20% 22.0 VDC

@ 20% ≦ load < 50% 21.4 VDC

@ load ≧ 50% 20.2 VDC

Low DC Warning Return Voltage@ load <20% 23.0 VDC

@ 20% ≦ load < 50% 22.4 VDC

@ load ≧ 50% 21.2 VDC

Low DC Cut-off Voltage@ load <20% 21.0 VDC

@ 20% ≦ load < 50% 20.4 VDC

@ load ≧ 50% 19.2 VDC

> 90 %

No Load Power Consumption < 20 W

Saving Mode Power Consumption < 10 W

OUTPUT

AC Voltage Regulation (Batt. Mode) 230VAC ± 5%

Surge Power 4000VA 6000VA

Waveform Pure sine wave

PHYSICAL

Dimension, D x W x H (mm) 82 x 232 x 369

Net Weight (kgs) 4.3 4.3

ENVIRONMENT

Humidity 5% to 95% Relative Humidity (Non-condensing)

Operating Temperature 0°C - 55°C

Storage Temperature -15°C - 60°C

ice.

Efficiency

Page 103: PROLINK POWER BACKUP SOLUTION

102

Pure Sinewave Inverter Series

INVERTER

IPS Series 3KVA-5KVA

• Super efficient DC to AC conversion, minimizing charging losses.

• High frequency technology, provides critical overload protection.

• User selectable for accepting wider input voltage.

• Full automatic start operation and silent operation.

• Compact size for convenient use and storage.

• Small scale and cost effective inverter for home appliances and office equipment.

• Eco-friendly and non-polluting (green device).

Rear Panel

1. Battery connector2. Input protector3. AC input4. Inverter output

3000-5000VA

PROLiNK® IPS3001/IPS5001 Inverter Series is a compact design of inverter system which converts DC power to AC

power with high efficiency conversion. The system is an economic ideal for provide clean and stable power for any

home or small office application such as TVs, stereos, desktop or laptop computers and other. With built-in high dc

charger current, it is suitable to charge up to 100Ah battery. In addition, PROLiNK® IPS3001/IPS5001 Inverter Series

comes with comprehensive LCD display that provides system status, and user-friendly panel eases parameters

settings.

2

3

4 1 2 3 4 1

IPS3001 IPS5001

Page 104: PROLINK POWER BACKUP SOLUTION

103

Pure Sinewave Inverter Series

INVERTER

IPS Series 3KVA-5KVA

• Super efficient DC to AC conversion, minimizing charging losses.

• High frequency technology, provides critical overload protection.

• User selectable for accepting wider input voltage.

• Full automatic start operation and silent operation.

• Compact size for convenient use and storage.

• Small scale and cost effective inverter for home appliances and office equipment.

• Eco-friendly and non-polluting (green device).

Rear Panel

1. Battery connector2. Input protector3. AC input4. Inverter output

3000-5000VA

PROLiNK® IPS3001/IPS5001 Inverter Series is a compact design of inverter system which converts DC power to AC

power with high efficiency conversion. The system is an economic ideal for provide clean and stable power for any

home or small office application such as TVs, stereos, desktop or laptop computers and other. With built-in high dc

charger current, it is suitable to charge up to 100Ah battery. In addition, PROLiNK® IPS3001/IPS5001 Inverter Series

comes with comprehensive LCD display that provides system status, and user-friendly panel eases parameters

settings.

2

3

4 1 2 3 4 1

IPS3001 IPS5001

BATTERY

CHARGER

AUDIBLE ALARM

PHYSICAL

GENERAL SPECIFICATIONS

Battery Voltage

Battery low alarm voltage

Battery low shut-down voltage

Battery high voltage protection (fault)

Charger Current

Low Battery at Inverter Mode

Dimension(DxWxH)mm

Operating Environment

Storage temperature

Audible Noise

Net weight

Overload

Fault

Boost charger voltage (bat. Type)

Floating charger voltage (bat. Type)

Over charger Voltage

Full Specifications

INVERTER

MODEL IPS3001

Rated Power

INPUT

OUTPUT

Nominal Input Voltage

Input voltage range

Max AC Input Voltage

Nominal Input Frequency

Input voltage waveform

Wave from

Voltage Regulation (Inverter Mode)

Output Frequency

Nominal Efficiency

Capable of starting electric motor

Over-Load Protection

Transfer Time (AC to DC)

2.4KW/3KVA

230Vac

175Vac-280Vac(Normal) ; 90Vac-280Vac(Generator/Wide)

300Vac RMS

50Hz / 60Hz (Auto detection)

Sinusoidal

Pure sine wave (Inverter mode)

±10% RMS

50Hz / 60Hz ± 1Hz

90% peak

1.5HP

fault after 10s@110%~150% loadfault after 5s@≥150% load,<=200% load

Normal range : 10ms (typical) 15ms (max) Generator/wide range: 20ms (typical) 40ms (max)

24.0Vdc ± 0.6Vdc

21.0Vdc ± 0.6Vdc

20.0Vdc ± 0.6Vdc

58.0Vdc

10A/20A selectable 10A @Vi/p<170Vac or Vi/p>280Vac; 20A@Vi/p=230Vac

28.8Vdc (Flooded); 28.2Vdc (AGM / Gel)

27.4Vdc (Flooded); 27.4Vdc (AGM / Gel)

30.0Vdc

Beep 1time every 2s

110%~150%load: beep 10s every 0.5s; >150% load: beep 5s every 0.5s then fault.

Continuously beep

330mm(D) x 268mm(W) x 76mm(H)

5.0KG

0°C to 45°C; 5% to 95% non-condensing

-15°C ~ 60°C

60dB maxProduct specifications are subject to change without further notice.

Page 105: PROLINK POWER BACKUP SOLUTION

104

INVERTER

BATTERY

CHARGER

AUDIBLE ALARM

PHYSICAL

GENERAL SPECIFICATIONS

Battery Voltage

Battery low alarm voltage

Battery low shut-down voltage

Battery high voltage protection (fault)

Charger Current

Low Battery at Inverter Mode

Dimension(DxWxH)mm

Operating Environment

Storage temperature

Audible Noise

Net weight

Overload

Fault

Boost charger voltage (bat. Type)

Floating charger voltage (bat. Type)

Over charger Voltage

Full Specifications

MODEL IPS5001

Rated Power

INPUT

OUTPUT

Nominal Input Voltage

Input voltage range

Max AC Input Voltage

Nominal Input Frequency

Input voltage waveform

Wavefrom

Voltage Regulation (Inverter Mode)

Output Frequency

Nominal Efficiency

Capable of starting electric motor

Over-Load Protection

Transfer Time (AC to DC)

4.2KW/5KVA

230VAC

175VAC-280VAC(Normal) ; 90VAC-280VAC(Generator/Wide)

300VAC RMS

50Hz / 60Hz

Sinusoidal

Pure sine wave (Inverter mode)

±10% RMS

50Hz / 60Hz ± 1Hz

90% peak

2.5HP

Fault after 5s@≥150% load; Fault after 10s@110%~150% load

Normal range : 10ms (typical) 15ms (max) Generator/wide range: 20ms (typical) 40ms (max)

48.0VDC

42.0VDC

40.0VDC

58.0VDC

25A @180V~280V; 20A @90V~180V

57.6VDC (Flooded); 56.4VDC (AGM / Gel)

54.8VDC (Flooded); 54VDC (AGM / Gel)

60.0VDC

Beep every 2s

110%~150%load: beep 10s every 0.5s; >150% load: beep 5s every 0.5s then fault.

Continuously beep

407mm x 350mm x 110mm

9.2KG

0°C to 45°C; 5% to 95% non-condensing

-15°C ~ 60°C

60dB maxProduct specifications are subject to change without further notice.

Page 106: PROLINK POWER BACKUP SOLUTION

105

INVERTER

BATTERY

CHARGER

AUDIBLE ALARM

PHYSICAL

GENERAL SPECIFICATIONS

Battery Voltage

Battery low alarm voltage

Battery low shut-down voltage

Battery high voltage protection (fault)

Charger Current

Low Battery at Inverter Mode

Dimension(DxWxH)mm

Operating Environment

Storage temperature

Audible Noise

Net weight

Overload

Fault

Boost charger voltage (bat. Type)

Floating charger voltage (bat. Type)

Over charger Voltage

Full Specifications

MODEL IPS5001

Rated Power

INPUT

OUTPUT

Nominal Input Voltage

Input voltage range

Max AC Input Voltage

Nominal Input Frequency

Input voltage waveform

Wavefrom

Voltage Regulation (Inverter Mode)

Output Frequency

Nominal Efficiency

Capable of starting electric motor

Over-Load Protection

Transfer Time (AC to DC)

4.2KW/5KVA

230VAC

175VAC-280VAC(Normal) ; 90VAC-280VAC(Generator/Wide)

300VAC RMS

50Hz / 60Hz

Sinusoidal

Pure sine wave (Inverter mode)

±10% RMS

50Hz / 60Hz ± 1Hz

90% peak

2.5HP

Fault after 5s@≥150% load; Fault after 10s@110%~150% load

Normal range : 10ms (typical) 15ms (max) Generator/wide range: 20ms (typical) 40ms (max)

48.0VDC

42.0VDC

40.0VDC

58.0VDC

25A @180V~280V; 20A @90V~180V

57.6VDC (Flooded); 56.4VDC (AGM / Gel)

54.8VDC (Flooded); 54VDC (AGM / Gel)

60.0VDC

Beep every 2s

110%~150%load: beep 10s every 0.5s; >150% load: beep 5s every 0.5s then fault.

Continuously beep

407mm x 350mm x 110mm

9.2KG

0°C to 45°C; 5% to 95% non-condensing

-15°C ~ 60°C

60dB maxProduct specifications are subject to change without further notice.

Pure Sinewave Inverter Series (Parallelable option)

INVERTER

• Pure sine wave output• 5KW per EPS module, paralleable to 45KW• 60A AC charger per module, up to 360A super large AC charger per system• Selectable input voltage range for home appliances and personal computers• Selectable charging current based on applications• Configurable parameter settng via LCD display• Compatible with mains voltage or generator power

Rear Panel

1. Operation panel2. RS-232 communication port3. AC input terminal4. AC output terminal 5. Battery input6. Circuit breaker7. Parallel communication ports8. Share current ports 9. Dry contact10. Communication ports

5000VA

This is a multi-functional inverter/charger, combining functions of inverter and battery charger to offer uninterruptible power for office and home appliances. Its comprehensive LCD display offers user-configurable parameters, such as battery charging current, and acceptable inputs voltage by setting easy-accessible buttons to fit different application.

BATTERYBATTERYBATTERY

Load

Utility

AC Output

Charging

AC Input

Discharging

Battery

9 3 4 5 210

8 7 6

5KVA INVERTER

Page 107: PROLINK POWER BACKUP SOLUTION

106

Full Specifications

INVERTER

MODEL IPS5002Rated Power 5000VA/5000WINPUTVoltage 220/230/240 VAC

Selectable Voltage Range 170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)

Frequency Range 50 Hz/60 Hz (Auto sensing)OUTPUTAC Voltage Regulation (Batt. Mode) 220/230/240VAC ± 5%Surge Power for 5 seconds 10000VA

93%

Transfer Time 10 ms (For Personal Computers)20 ms (For Home Appliances)

Waveform (Batt. Mode) Pure sine waveBATTERY Battery Voltage 48 VDCCC/CV Charge Voltage 56.4 VDCFloating Charge Voltage 53.6 VDCOvercharge Protection 60 VDCAC CHARGERMaximum AC Charge Current (Adjustable) 2.5~60 ACharging modes 3 steps for CC, CF and FloatingPARALLELMaximum Parallel units Up to 9 unitsParallel Type Single Phase or Three PhaseTransfer Time in Parallel Mode <40msPHYSICAL

INTERFACE

Dimension, D x W x H (mm) 400 x 438 x 88 (2U)Net Weight (kgs) 9.1

OPERATING ENVIRONMENTHumidity 5% to 95% Relative Humidity (Non-condensing)Operating Temperature 0°C to 55°C (De-rate to 4KW at 55°C)Storage Temperature -15°C to 60°C

ice.

Efficiency (Peak)

CommunicationDry Contact

Modbus RS-485Deliver signal to external device such as generator

Page 108: PROLINK POWER BACKUP SOLUTION

107

PROLiNK PVR

AUTO VOLTAGE REGULATOR

• Microprocessor control guarantees high reliability

• Selectable input voltage range

• Time delay function eliminates transients that can affect connected equipment

• Provide stable output voltage

• Provide under-voltage, over-voltage, over-heat and over current protection

• Provide surge and spike suppression

Rear Panel

1. Output sockets2. AC input terminal

3. Grounding (black)4. AC output terminal

5000VA-10KVA

PROLiNK PVR Series is designed to automatically maintain

a constant voltage level to protect sensitive electronics

from brownouts, under voltages and over voltages. The

PROLiNK PVR takes efficiency to a new level with its

microprocessor controller tailored to allow extremely fast

response for detecting and regulating voltage. Equipped

with a time-delay function, the PVR is able to protect

connected devices from power-back surges. This high

performance AVR comes with the versatility to fit all kinds

of equipment with its wide input voltage range selection.

The PROLiNK PVR provides you with the optimum solution

for your everyday needs.

1

1 231

2

24

Page 109: PROLINK POWER BACKUP SOLUTION

108

Full Specifications

AUTO VOLTAGE REGULATOR

MODEL PVR500D/M PVR1000D/M PVR1500D/M PVR2000D/M PVR3000D/M PVR5000D/M PVR8000D/M PVR10000D/M

CAPACITY500 VA /400 W

1000 VA /800 W

1500 VA /1200 W

2000 VA /1600 W

3000 VA /2400 W

5000 VA /4000W

8000 VA /6400W

10000 VA /8000W

INPUT

Voltage 220 VAC or 230 VAC 220 VAC or 230 VAC

Voltage Range110 VAC - 270 VAC or 110 VAC - 280 VAC (Wide input window)

140 VAC - 260 VAC or 150 VAC - 270 VAC (Normal input window)

140 - 260 VAC or 140 - 270 VACOption 1: 100 - 260 VAC or 100 - 270 VACOption 2: 80 - 260 VAC or 80 - 270 VAC

Frequency Range 60 Hz / 50 Hz

OUTPUT

Voltage 220 VAC or 230 VAC 220 VAC or 230 VAC

Voltage Regulation -10% ~ +10%

EFFICIENCY

Normal Mode 95% 98%

AVR Mode 92% 92-95%*

PROTECTION

Delay Time 3 minutes or 10 Seconds

Full Protection Over-voltage, under-Voltage, over-heat and over current Protection

INDICATORS

LED Indicator Normal indicator, AVR indicator, delay time setting and fault indicator

Digital or Meter Display Input and output voltage

PHYSICAL

Dimension, D X W X H (mm) 197 x 110 x 124 234 x 134 x 181 297 x 150 x 199 450 x 210 x 237

Net Weight (kgs) 2.4 3.91 5.4 6.55 8.56 10.96 14.31 15.95

ENVIRONMENT

Operating Temperature 0- 40°C

Humidity 0-90 % relative humidity (Non-condensing)

ice.D - LCD Display; M - Analog Display

Page 110: PROLINK POWER BACKUP SOLUTION

109

Rechargeable Power Adapter

DC UPS

• Built-in Li-ion battery• Microprocessor controller guarantees high reliability• Auto start when plugged in• Manual power off switch• Multi-color indicator • Overload, short-circuit, over-charge and over-discharge protection

The PROLiNK® PDC12V Rechargeable Power Adapter is designed to provide power backup for small electrical appliances. It comes with a universal voltage of 90 - 264 VAC, which is able to power up most electronic devices such as networking products, IP cameras and security systems.

The product also with built-in high quality components that ensures optimal performance and safety protection such as over-discharge, over-charge, short-circuit and overload.

PDC12V is small and light-weight, which suits users who are looking for a portable power backup solution for their devices.

PDC12V

MODEL PDC12V

AC INPUT

Voltage Range 90 VAC ~ 264 VAC

Frequency 50 or 60 Hz

Surge protection 1.5KV (Optional K.21 enhanced, 6KV)

DC OUTPUT

Voltage 12VDC ± 5%

Max. Power 25W (2.1A)

BATTERY

Type Lithium-ion Battery

Voltage 3.7VDC

Capacity 2600mAh

Typical Charging Time 3 hours recover to 90% capacity

PROTECTION

Battery Deep Discharge, Over-charge and Short Circuit Protection

Input/Output Fuse for Short Circuit and Overload Protection

INDICATORS

LED

Full Battery Green lighting

Battery Charging

Battery Discharging

Fault Red lighting

PHYSICAL

Input Plug Mounted on the housing (NEMA/EU/UK)

Output Cable 1m Length (DC Male Jack, OD 4mm, ID 1.7mm)

Dimension, D x W x H (mm) 68 x 42 x 74

Net Weight (g) 280

Product specifications are subject to change without further notice.

Constant flashing on Green LED

Quick flashing on Green LED

Page 111: PROLINK POWER BACKUP SOLUTION

110

DC UPS

Back-up (PBU) Unit

The PROLiNK® PBU5022 / 5027 Back-Up (PBU) unit is a user-friendly lighting power supply unit that is suitable for home/ outdoor settings. This portable-sized unit may appear small but it comes with an amazing 230VDC output that can be used for powering up energy saving light bulbs of up to 11W. The unit is designed with the flexibility to be powered by regular AC supply or via the supplied battery. The PROLiNK PBUs’ potential is best realized for users that commonly experience power blackouts.

On top of its amazing performance, this unit is brilliantly designed to allow a range of flexible display methods: vertically or horizontally standing, wall-mounted or as a portable display. Moreover, the PBU series comes with the choice to select between a B22 or E27 light bulb terminal. The PROLiNK Back-Up unit is the perfect cost-effective solution for your lighting requirements.

PBU5022/5027

• 40W DC UPS • Equipped with one lamp holder for energy saving bulb • 3 set of DC-powered outlets for energy saving bulb • Off-mode charging

• Overload protection in battery mode and short circuit protection • Three indicators available• 3-step charging design to extend battery life

MODEL PBU5022/5027

CAPACITY 50VA/40 W

INPUT

Nominal Voltage 230 VAC

Voltage Range 100 VAC - 300 VAC

OUTPUT

Output Voltage (AC Mode) 100 VDC - 300 VDC

Output Voltage (Batt. Mode) 160-230 VDC ± 10%

Waveform (Batt. Mode) DC Output

BATTERY & CHARGER

Battery Type and Numbers 12V 7Ah x 1

Battery Voltage 12 VDC

Bulk charging voltage 14.5V ±1.5%

Floating Voltage 13.7V ±1.5%

Charging Current 1 A

Typical Recharge Time 6 hours recover to 90% capacity

INDICATORS

Full battery at Line Mode Green lighting

Charging battery at Line Mode

Normal battery voltage at Battery Mode Yellow lighting

Low battery at Battery Mode

Output short-circuited Red lighting

Overload

Overcharge Red LED staying on for one second and off for 4 seconds

PHYSICAL

Dimension, D x W x H (mm) 209 x 87 x 200

Net Weight (kgs) 2.7

ENVIRONMENT

Humidity 0-90 % RH @ 0- 40°C (non-condensing)

Noise Level Less than 40dB

Green flashing every 2 seconds

Yellow flashing every seconds

Red flashing rapidly every 0.5 seconds

Product specifications are subject to change without further notice.

Page 112: PROLINK POWER BACKUP SOLUTION

111

External Battery Charger (PEC)

SOFTWARE & ACCESSORIES

PROLiNK External Charger (PEC) is an additional external smart charger for PROLiNK Online UPS system. It designed with isolation structure and operated in parallel with several units for charging capability expandable. 

Product specifications are subject to change without further notice.

MODEL PEC20-24 PEC15-36 PEC15-48 PEC12-72 PEC10-96 PEC24-240INPUTNominal Voltage 230VACVoltage Range 170~280VAC 110~300VACNominal Frequency 50/60HzInput Current (max) @ full load 8A 60AOUTPUTNominal Voltage 24VDC 36VDC 48VDC 72VDC 96VDC 240VDCOutput Current (max) 20A 15A 12A 10A 24AFloating Charging Voltage 27.3VADC 41.1VDC 54.8VDC 82.2VDC 109.6VDC 273.6VDCEFFICIENCYAC Mode Up to 85%PROTECTIONFull Protection Over-voltage, Thermal control, Over current, Short circuit, Reversal polarityINDICATION

LED Display

Charger ON – Green LED

N/ABoost Charging Status – Yellow LED

Floating Charging Status – Green LEDLow Charging Voltage – Red LED

PHYSICALDimension (mm) D x W × H 300 x 177 x 90 570 x 250 x 215Net Weight (kgs) 3.1 14ENVIRONMENTRelative Humidity <95% (Non-condensing)Operation Temperature 0 ~ 40°CNoise Level <50dBIP Class IP20

With PROLiNK External Battery Cabinet

Expandable PROLiNK battery cabinets

UPS Expandable Charger units

Expandable battery units

UPS Expandable Charger units

With External Battery Bank

• Input PFC control• Back feed protection• Three-stage smart charging• Short circuit and over voltage protection• Maximum current restriction• Redundancy operation

Page 113: PROLINK POWER BACKUP SOLUTION

112

SOFTWARE & ACCESSORIES

Automatic Transfer Switch

PROLiNK Automatic Transfer Switch (ATS) is designed to allow two independent power inputs to supply power to the

connected load. In the event where the primary power source fails, the ATS automatically transfers the backup

connection to the secondary power source without any interruption, providing seamless electrical power and the

highest protection for your equipment. The PROLiNK ATS is also designed to automatically transfer the connection

backto the primary power source once it has detected restored power.

• 16A maximum input current

• Powered by two separate independent power sources

• Dual power supply for redundancy

• Provides seamless power switch for IT equipment

• Preferred source selection on front panel

• 19” rack-mount design (1U)

• Built-in USB and RS-232 interface

MODEL ATS16-RCurrent Rating 16AINPUTInput Voltage 230VACAcceptable Input Voltage 207 ~ 253VACInput Frequency 50Hz/ 60HzOUTPUTOutput Voltage 230VACMaximum Output Current 10A for IEC-C13 Outlets; 16A for IEC-C19 OutletsCONNECTIONInput 2xIEC-C20 InletsOutput 8xIEC-C13; 1xIEC-C19Communication USB/ RS-232Transfer Time 9 ~ 12ms (Typical)PHYSICALDimension (mm) D x W × H 310 x 430 x 44Net Weight (kgs) 3.65ENVIRONMENTOperation Temperature 20 ~ 95% Relative Humidity @ -5°C ~ 45°C (Non-condensing)

Product specifications are subject to change without further notice.

Page 114: PROLINK POWER BACKUP SOLUTION

113

SOFTWARE & ACCESSORIES

Automatic Transfer Switch

PROLiNK Automatic Transfer Switch (ATS) is designed to allow two independent power inputs to supply power to the

connected load. In the event where the primary power source fails, the ATS automatically transfers the backup

connection to the secondary power source without any interruption, providing seamless electrical power and the

highest protection for your equipment. The PROLiNK ATS is also designed to automatically transfer the connection

backto the primary power source once it has detected restored power.

• 16A maximum input current

• Powered by two separate independent power sources

• Dual power supply for redundancy

• Provides seamless power switch for IT equipment

• Preferred source selection on front panel

• 19” rack-mount design (1U)

• Built-in USB and RS-232 interface

MODEL ATS16-RCurrent Rating 16AINPUTInput Voltage 230VACAcceptable Input Voltage 207 ~ 253VACInput Frequency 50Hz/ 60HzOUTPUTOutput Voltage 230VACMaximum Output Current 10A for IEC-C13 Outlets; 16A for IEC-C19 OutletsCONNECTIONInput 2xIEC-C20 InletsOutput 8xIEC-C13; 1xIEC-C19Communication USB/ RS-232Transfer Time 9 ~ 12ms (Typical)PHYSICALDimension (mm) D x W × H 310 x 430 x 44Net Weight (kgs) 3.65ENVIRONMENTOperation Temperature 20 ~ 95% Relative Humidity @ -5°C ~ 45°C (Non-condensing)

Product specifications are subject to change without further notice.

SOFTWARE & ACCESSORIES

PDU & Maintenance Bypass Switch

The PDU & Maintenance Bypass Switch is an external power distribution unit used in conjunction with UPS systems or large-scale voltage regulators. This device enables the UPS to be isolated for scheduled maintenance or replacement without interrupting the power to the load.

• Master-slave function for energy saving• Choose between a rack or tower design to fit into any working environment• Simple installation with plug-and-play socket type• Suitable for all UPSs up to 3kVA

MODEL MBS16-R (I/U/S/N) (*) MBS16-T (I/U/S/N) (*)Current Rating 16AVoltage Rating 208/ 220/ 230/ 240/VAC

Master/ Slave FunctionYes. When power consumption in Master Outlet is lower

Master/ Slave Function than 20W (±5W), it will shut off the power for slave outlets.

NA

CONNECTION

InputAC Power 1 x IEC (16A) Connector & 1 x Customized Plug CableUPS Input

1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k)UPS Output

Output

IEC 5 x IEC 10A Socket + 1 x IEC 16A Socket(with 2 circuit breakers)

8 x IEC 10A Socket + 1 x IEC 16A Socket(with 2 circuit breakers)

Schuko 4 x Schuko 16A SocketsUK 4 x UK 13A SocketsNEMA 5 x NEMA 20A Sockets x NEMA 20A Sockets

PHYSICAL

Dimension (mm)D x W x H

Transfer Time 80 x 438 x 50 180 x 160 x 50Transfer Time

80 x 438 x 60 180 x 200 x 50Transfer TimeTransfer Time 80 x 438 x 50 180 x 160 x 50

Net Weight (kgs) 1.50 1.30ENVIRONMENTOperation Temperature 20 ~ 95% Relative Humidity @ -0°C ~ 40°C (Non-condensing)

Product specifications are subject to change without further notice.

Rotary bypass switch

Circuit breaker

Slave output sockets (10 A)

Master output socket (10 A)

Master output socket (16 A)

IEC 16A input socket

IEC 16A socket connecting UPS output

IEC 16A socket connecting UPS input

Master/Slave function switch

IEC UK NEMASchuko

Page 115: PROLINK POWER BACKUP SOLUTION

114

SOFTWARE & ACCESSORIES

SNMP CardIntegrated with our latest ViewPower software, the SNMP manager operates as an enhanced communication solution for your UPS system. It allows you to remotely manage and monitor your UPS system via internet connectivity. Once connected to the internet, the ViewPower software provides you access to remotely program or even shut down your UPS system.

• Allows control and monitoring of multiple UPSs through RJ-45 network connection• Real-time dynamic graphs reflecting UPS data (Voltage, frequency, load level and battery level)• Warning notifications via audible alarm, broadcast, mobile messenger, e-mail and SNMP traps• Historical data logging• One click easy firmware upgrade• Password security protection and remote access management• Supports optional environmental monitoring detector for temperature, humidity and smoke

Modbus CardThe ModBus Card provides UPS and PV inverter systems with the functionality to communicate with PCs through the ModBus Protocol.

• Adopts ModBus RTU Protocol• Comes with functions that includes read Holding Registers and write Registers• RS232 and RS485 interface

AS-400 CardThe AS-400 communication card is designed with a high quality contact closure board that accurately converts UPS signals into dry contacts for users to monitor UPS events that are most concerned to them. By setting the jumper, the AS-400 communication card allows you to select various status indicators such as; UPS alarm, UPS failure, Bypass, Low Battery etc.

• Capable of selecting the status of the dry-contact signal by setting the jumper to meet different application requirements• Suitable applications include; IBM Server, Personal PC & Workstations equipments, Auto-controlled industrial equipment & communication applications

Rack Mount SliderThe PROLiNK Rack-mount slider kit offers you the best solution to install a PROLiNK UPS system into a 19” server rack enclosure. This kit comes with a pair of heavy duty sliders that are attached with quality assured ball bearings to ensure that your server can slide effortlessly into and out of the rack. Furthermore, the PROLiNK Rack-mount slider kit includes a superior quality front and rear mounting brackets to withstand the weight of your UPS.

• Simple and easy installation• Suitable for PROLiNK Rack Mount Online UPS system• Slider length available in 700mm and 1100mm to suit different types of cabinet

Page 116: PROLINK POWER BACKUP SOLUTION

115

SOFTWARE & ACCESSORIES

Viewpower – UPS Management SoftwareViewPower is an advanced UPS management software that is designed for users to remotely monitor and manage multiple UPS units in a networked environment, either by LAN or INTERNET. The ViewPower software is able to protect your important data by executing a safety OS shutdown during power failure. Better yet, this software gives users the ability to store programming data and also scheduled a UPS shutdown when necessary.

• Allows control and monitoring of multiple UPSs via LAN and INTERNET• User-friendly power analysis graphs• Real-time dynamic graphs of UPS data• Safety OS shutdown to prevent data losses during power failure• Warning notifications via audible alarm, broadcast, mobile messenger, and e-mail• Scheduled UPS on/off, battery test, programmable outlet control, and audible alarm control• Password security protection and remote access management• Supports multiple OS and local languages

ViewPower Pro Management Software Integrated with SNMP card or Modbus card, ViewPower Pro is a UPS management software to monitor and manage from one to multiple UPSs in a networked environment, either LAN, INTERNET, and serial connection. It’s also compatible with Shutdown Wizard which is a highly specialized and designed tool to perform shutdown task. The system diagram is shown as below:

• Compatible with SNMP and Modbus cards.

• Centralized control and monitor up to 1000 UPSs in LAN, Internet, or serial networks.

• Allows simple remote monitoring via web browser.

• Offers quick overview for multiple-UPS monitoring in Text and Graphic view

• Offers user-customized background picture for graphic view with simple drag and drop.

• Scheduled UPS on/off, battery test, and scheduled wake on LAN programs.

• Supports multiple OS and languages

Page 117: PROLINK POWER BACKUP SOLUTION

116

APPENDIX

Battery CabinetMODEL

Battery Quantity Cabinet Dimension (CM)

X1

X2

X3

X4

X6

X8

X12

X16

X20

X32

X40

5

10

14

20

28

-

-

62

-

-

-

17AH

2

4

6

12

16

28

30

40

56

62

-

24AH

1

2

3

4

6

8

12

16

20

32

40

100AH

Weight(Kgs)

3.5

6.5

7.8

14.5

21

23

31

40.5

46.5

73

132

N.W

43

43

58

45

58

78

78

78

95

78

106

Length

21

43

43

47

47

47

47

47

47

88

88

Width

29

29

29

61

62

62

91

119

119

119

119

Height

1

2

3

4

6

8

12

16

20

32

-

65AH

2

4

6

8

12

20

24

32

40

62

-

38AH

Page 118: PROLINK POWER BACKUP SOLUTION

SINGAPOREFIDA INTERNATIONAL (S) PTE LTDBlock 16 Kallang Place#06-02, Singapore 339156Tel: (65) 6357 0668

MALAYSIAFIDA SYSTEMS (M) SDN BHDTel: (60) 3 8024 9151

INDONESIAPROLiNK INDONESIATel: (62) 21 3483 1777

Technical Support Hotline:Singapore (65) 6357 0666Malaysia (60) 3 8023 9151Indonesia (62) 21 3483 1717

Operating HoursMonday - Friday: 9.00am - 6.00pmClosed on Saturdays, Sundays & Public Holidays


Recommended