MULTIGAS ANALYSIS

Advanced Technology for

Speed, Accuracy and Reliability

• PHASEINgasanalysisbenchwarmsupandbegins providingfullaccuracyofgasconcentrationdataand agentidentificationinlessthan20seconds.Automatic zerocalibrationatstartup,andthenonceevery8hours ofcontinuoususe,eliminatesmultiplezeroingmessages andthedropoffofcriticaldata.Alight-emittinggasinlet providesastatusindicatortotheuser,detectingthe presenceofaNomolinesamplinglineandproviding color-codedinformationaboutbenchstatusand thealarmsystem.

• Servomexparamagneticoxygensensorprovidesinspired oxygen(FiO2),expiredoxygen(FeO2)andinstantaneousO2 values.Anon-depletingsensor,itdoesnotrequirereplacement.

• Nomoline“no-moisture”gassamplinglineprovideswater andfiltrationmanagementwithouttheneedforwatertraps. Achoiceofsingleandmultipleuseversionsavailable.

Speed and Performance in a Small Package

SpacelabsHealthcare’sMultigasModuleincorporatesadvancedtechnology– includingthePHASEINgasanalysisbench,theNomoline™(no-moisture)gas samplinglineandtheServomexO2sensor–forincreasedperformance andreliabilityinmonitoringCO2,N2O,O2andanestheticagents.

92518MultigasModule

ThisMultigasModuleiscapableofidentifyinganddisplayingagentvaluesinlessthan 20secondsafterstartup,andissuitable foruseonallpatientpopulations–fromnewbornthroughadult–duetoitslowsampleflowrate(50ml/min). Acompactsolutionfor yourcompletegasanalysisneeds,itcanbeintegrateddirectlyintoSpacelabspatientmonitoringsystems.

Page 2: MULTIGAS ANALYSIS - Spacelabs Healthcare

www.spacelabshealthcare.com

Spacelabs Healthcare Company Headquarters5150 220th Ave. SE, Issaquah, WA 98029PO Box 7018, Issaquah, WA 98027-7018

Telephone: +1 425-657-7200In North America: +1 800-522-7025Fax: +1 425-657-7212

© 2011 Spacelabs HealthcareSpecifications subject to change without notice. Ultraview SL and Xprezzon are trademarks of Spacelabs Healthcare. Other brands and product names are trademarks of their respective owners.

Product may not be available in all locations. Check with your local Spacelabs representative.

M1122-de11

For all Patient Populations – Neonate through Adult

TheMultigasModule’shighlyefficientPHASEINgasanalysis benchusesasampleflowrateofjust50ml/min–allowing side-streamgassamplingonallpatientpopulations.

Compact & Compatible

ForintegrationwithSpacelabsXprezzon™andUltraviewSL® patientmonitoringsystems.

Performance Specifications

WarmUp <20secondsforconcentrationreporting,automaticagentidentification,andfullaccuracyspecification

SampleLineFlow50ml/min±10ml/min

Occlusion Automaticallydetectsandattemptstoclear samplelineocclussions

SuspendSampling InSuspendMode,sensorscontinuetooperatebutpumpstopsandwaveformsandnumericzonesarecleared,allowingsensorstoremainwarmedup

Comprehensive Gas Analysis

• RELIABLECO2&multigasmonitoring• FASTO2technology• AUTOagentidentification -Isoflurane -Desflurane -Sevoflurane -Enflurane -Halothane