Match UPSProduct ManagementJuly 2004
Match UPSProduct Management
July 29th, 2004
RangeTopologyUnique Selling PointsKey FeaturesAccessoriesApplications
Contents
Match UPSProduct Management
July 29th, 2004
“Even a moment’s disruption can have devastating effects on power sensitive customers such as internet service providers, data centres, wireless telecommunications networks, on line traders, computer chip manufacturers and medical research centres. For these customers, power disruptions can result in data corruption, burned circuit boards, component damage, file corruption and lost customers.” - “Electrical Power Interruption Cost Estimates for Individual Industries, Sectors and US Economy” February 2002, US Dept of Energy, Office of Power Technologies
“The system and its data can become corrupt as a result of power failure…a UPS can protect the system if power is lost. A UPS usually provides…temporary power which may be enough to permit a graceful shutdown” - Special Publication 800-34 Contingency Planning Guide for Information Technology Systems, National Institute of Standards and
Technology, June 2002
Match UPSProduct Management
July 29th, 2004
Models available include
500, 700, 1000, 1500, 2200 & 3000VA tower models 700, 1000, 1500, 2200 & 3000VA 19inch rackmount models Longer runtime (L) version for 700VA and 1000VA 2200 and 3000VA with DC connector for additional batteries
Matching battery cabinets
Range
Match UPSProduct Management
July 29th, 2004
Control Inverter
Boost
Buck
Normal
Battery
SafetyRelay
AVRRelay
IN
OUT
Line Interactive
Topology
Match UPSProduct Management
July 29th, 2004
A Line Interactive UPS provides:
Battery back up and voltage stabilisationAs well as providing back up power from the battery when the mains fails, the UPS filters the mains during normal operation, regulating the incoming voltage
Cost effective UPS protection Lower price compared to on line UPS
Topology
Match UPSProduct Management
July 29th, 2004
A Line Interactive UPS provides:
Small break in powerDuring the switch from mains to battery, there is a small loss of power to the load (typically 2-4ms, not affecting most computer type loads)
Medium degree of protection When compared to on line (double conversion) UPS
Topology
Match UPSProduct Management
July 29th, 2004
Excellent High Voltage ProtectionThe Match UPS will protect itself and the
supported load up to 350VAC. Most UPS will damage themselves or the load if the input voltage exceeds 300V
Low ‘Green’ Power Consumption Compared to other line interactive UPS, the
power consumption is extremely low during normal operation
Unique Selling Points
Match UPSProduct Management
July 29th, 2004
Unique Selling Points
Optimised Sinewave Output The output waveform is sinusoidal with a linear load, and with a crest load is slightly flattened. This avoids high current peaks on the electronics and the battery, and still provides high efficiency.
This is the optimal solution between sinewave and stepwave UPS outputs. Stepwave UPS can cause some electronic equipment to malfunction.
Match UPSProduct Management
July 29th, 2004
Additional USPs, Match 2200 & 3000 Extremely wide input voltage window
At 165-275V (500-1500VA) and 140-305V (2200 & 3000VA), the output voltage is limited to 190-254V. This minimises the need for battery use, extending battery life
Battery charging even at 140VAC Even in poor mains conditions there is a fast recovery of battery power, increasing up time and battery life
High battery recharge current
When additional battery packs are connected, the charger current automatically increases to 10A, ensuring much faster recharge time
Match UPSProduct Management
July 29th, 2004
Additional USPs, Match 2200 & 3000
Deep battery calibration testThe actual battery capacity can be tested and calibrated. This ensures the predicted runtime stays accurate throughout the life of the UPS
Load dependent end of dischargeIf the discharge time is shorter, batteries may be discharged deeper. This features ensures maximum runtime is is given at any load level, without the risk of damaging the battery during longer power failures
Match UPSProduct Management
July 29th, 2004
Automatic voltage regulationThe buck and boost function minimises battery operation, increasing the battery life. With an inout voltage window of 165-275V, the output voltage is limited to 190-254V
Crest factor input acceptance 6:1The Match is especially suited for computer loads, and no oversizing is necessary
Key Features
Match UPSProduct Management
July 29th, 2004
Battery start (cold start)Allows the UPS to be switched on without mains power, for mobile applications or to perform a quick action during a mains failure
Extended communicationRS232, SNMP and contact interface communication (plug in options for Match 700L and above)
Key Features
Match UPSProduct Management
July 29th, 2004
Key Features – Superior Battery ManagementAutomatic monthly
battery testing
Charger off at end of discharge period
Automatic boost charge
2 hours battery recharge time
The UPS keeps running in normal operation over the test, rather than switching to battery. If the battery is damaged or empty, the load is still supported
Lowest battery temperature during mains operation
Prevents battery depletion beyond recharge capability
Safe battery test
Alerts the user that the batteries need to be replaced
For areas with poor mains, ensures a faster recharge time than with float charge only
On battery at less than 5% load, the UPS performs an automatic shutdown to protect the battery. This function can be disabled
Means that loads even in very poor mains areas can be supported more than once during a shift
The electronic design of the UPS means the battery temperature is very low, increasing battery life
No load shutdown
Match UPSProduct Management
July 29th, 2004
Accessories SNMP Card Can be used with Match 700L upwards
Presents UPS information across a network via: SNMP Agent (one or more NMS can monitor, manage and control the UPS) Web Server (UPS data in HTML format, so standard internet browser can be used to monitor UPS) Easy installation through RS232 slot SNMP box also available
Network Protection Software CD packed with UPS free of charge, with intelligent communication cable. Simple installation Virtually invisible operation under normal conditions Provides a graceful shutdown of load after a lengthy mains failure Supports all major operating systems DataShield supplied for JAVA supported operating systems
Match UPSProduct Management
July 29th, 2004
Accessories Relay Interface Card Can be used with Match 700L upwards Easily installed into CardConnect slot at rear of UPS Provides 4 potential free contacts for:
Mains failure
General alarm
Battery low
Bypass active
and a 9 pole Sub-D connector
Manual Service Bypass Contains a manual bypass switch Allows for maintenance or testing of UPS with no interference to the protected load Pluggable as standard, but can be hardwired using the internal terminal strip
Match UPSProduct Management
July 29th, 2004
PCs
Servers
Workstations
Hubs, switches and routers
Cash register systems (EPOS)
Fax, modem, ISDN adaptors
Applications