LAKOS High E
cienc
y Pr
odu c
t TM
Series of LAKOS HTH 1950 separators used to keep sand our of customer cooling tower installation in Mexico.
LAKOS HTH 0500 used to keep water tower condenser free of solids in chilled water system.
LAKOS HTH 3500 used to keep wind-blown sand from damaging heat exchangers and other equipment in manufafacturing plant in New Mexico.
LAKOS High E
cienc
y Pr
odu c
t TM
Solids Collection – Zero Liquid Loss and Capture Separated Solids
Purge Options – Automated Solids Purge
Tower Basin Sweeping with HydroBoosters
• Captureseparatedsolidseasilyandreturnliquidback to system
• Removecollectedsolidswithoutinterruptingsystemflow
• Single(1)bagSolidsRecoveryVessel(SRV)availableintwosizes:16-inch(SRV-816)and33-inch(SRV-833)
• Three(3)bagClosedRecoveryVessel(CRS)for10”separators and larger
• Filterbagsavailablefrom10micronto50microns• Optionalindicatorpackageprovidesconvenientway
todeterminebagchange-outsonSRV-816,SRV-833andCRS-836B
• Optionaldrycontactavailableforremotemonitoring.CanbetiedtoBMS(BuildingManagementSystem)
• LowerwastewatertreatmentcostsFormoreinformation,seeLAKOSLiteratureLS-576andLS-622
• PurgeseparatedsolidsfromLAKOSSeparatorsatpre-determinedintervals.LAKOSControllersprovideoptionstocontrolandadjustpurgeintervalsandduration
• LAKOSPurgevalvesarecapableofhandlingalltypesoffine,fibrous,andmildlyabrasivesolids
• EFS:ElectricBatteryBackupFail-safevalveautomaticallyclosesthevalveintheeventofapowerfailure
• LAKOSControllersfeaturesolidstatereliability,thusremovingtheneed for routine maintenance
• AllLAKOSValvesareCEcompliantFormoreinformation,seeLAKOSLiteratureLS-238andLS-913
• PatentedLAKOSHydroBoosterscreatesweepingactiononthecoolingtowerbasinfloortoreduceunder-depositcorrosion,coolingtowernozzleclogging and extend cooling tower life
• HBandeHBHydroBoostersVortexingactionmovescoolingtowersolidstowardsthefiltrationsystembyusingdirectedturbulence,therebypreventingsolidsaccumulationonthebasinfloor,andremovingthefoodsourceforbiologicalactivity
• Minimizemanualbasincleaning,coolingtowermaintenance,riskofinjuryassociatedwithbasinfloorcleaning,andsystemdowntime
•HBandeHBHydroBoostersaredesignedfordurability and to resist cooling tower water chemicals
Filtered water sent downstream to chillers/heat exchangers
Solids are directed to LAKOS Separator
Filtered waterflows to LAKOSHydroBoosters
LAKOS Separatorand System
HydroBoosters
ToLAKOS
Separator
Cooling Tower
AutomaticBallValve
ABV2
CRS-836-B(ClosedRecovery
Vessel)
SRV-833(SolidsRecoveryVessel)
SRV-816