    EURA E ed SE FUNCTIONING CHECK AND FAULTS FINDING CHARTSThe following check must be executed with the help of the Instructions Manual

    REMARK: The lasting check must be executed with a tester on the flow of the , after disconnecting the boiler and after

    disconnecting the connector relevant to the component or circuit to be tested.

    For the tests on the electrical components check the connections and the contacts of the connections even if not indicated

    ABBREVIATIONS: PCB/M = Modulation PCB - PCB/I = Flame check PCB

    NO Check the connection and insert the external switch

    NO NOYES

    Check the supplying cables and

    the connections

    Give the electrical supply

    to the boiler with thebotton O/I

    Does the green led flash?

    Is the boilerelectrically

    supplied?Are there 230v

    between L.N. of

    M11 of the

    PCB/M? YES Replace the fuse and the PCB/MYES

    Is the yellow led off? NO - The positioning of the Mixing valve is disabled (parameter 9 on 1)- The antifrost system is on

    YES WAIT 80 SECONDS FOR THE POSITIONING OF THE MIXING VALVE

    YES The display shows the error code. If the led is constantly on it is possible to reset

    with the relevant button, if it is flashing read the following instructions

    E01 Block of the ignition board Reset with the button RESETE02 Block for lack of burner ignition Reset with the button RESET

    E05 Damaged flow sensor Replace the sensor

    E12 Damaged Micro-storage sensor Replace the sensor

    NO E18 Water filling in action (led off) Wait 4 minutesE19 Water filling not completed within 4 minutes Reset the el. network

    E21 Lack of water. 3 tempts of filling already done Reset the el. network

    E22 EPROM errors. Demand for programming Reset the el. network

    E 29 Modulator coil in short circuit Replace the coil

    E31 Eventual not compatible remote control Replace the eventual remote

    Is the red led off?

    E 68 Eventual not programmed remote Program it

    YESMove the boiler on

    Summer

    Does the green led switch

    on?

    NOReplace the

    PCB/M

    YES NO Controllare il buon funzionamento del galleggiante

    o sostituire il micro del flussostato

    NO

    Regulate the DHW at

    maximum and open an

    hot water tap.

    Does the boiler switch

    on?

    Is the contact of

    DHW micro switch

    closed ?

    ( continuity between

    26 and 29 of M5 of

    PCB/M

    YESReplace the PCB/M after checking that the wires of

    the micro are connected and entire

    YES NO

    Replace the PCB/MNOIs the pump on? Are there 230vbetween the clampsof the pump? YES Replace the pump

    YES NO Replace the pressure switch

    NO

    NO

    With boiler off is the

    contact between C

    and NC of the Flue

    press. switch closed? YES Does the fan turn?

    ( only SE models)

    Are there

    230v on the

    clamps of

    the fan?

    YES Replace the fan

    Switch on the boiler. If

    there are not 230v between

    41 and 48 of M4 replace the

    PCB/I. If not, replace the

    PCB/I

    YES

  • 7/30/2019 z Eura Technical 2003 Manuale

    15/24

    NO Replace the PCB/I

    NODoes the sparkle appear

    on the burner?

    Are the ignition

    electrode and its

    cable dirty or

    damaged?

    YESClean or replace

    electrodes and cable

    For the SE models: check that

    the contact between C and NO of

    the flue press.switch is closed,

    that the pipes are connected and

    that the press.switch is efficient

    YES Replace the damaged one

    NO REMARK: for the flue therm.As first check the draughtNO Replace the damaged one

    NO

    Have the safety

    thermostat and

    the flue therm.(E model) the

    contact closed?

    YES Replace the PCB/I

    Does the burner switchon?

    During the

    ignition, are

    there 230 vbetween the

    coils of the gas

    valve?

    (reset if the

    boiler goes in

    blockYES Replace the valve if gas arrives from the network (IN

    plug)

    YES NO

    Check the regulation of power of slow ign. And of

    minimum power of gas valve ( see the Manual )

    Replace the PCB/M

    Does the flame remain in

    slow ignition for 8 secs? NO

    Has the power

    of slow ignition

    been properly

    regulated?

    (see Manual)

    YES Is the modulator

    interrupted or in

    short circuit ?

    NO

    YES Replace the modulatorYES

    NO Does the flame

    remain at minimum

    or at slow power?

    YESRegulate the maximum

    power of the gas valve as

    indicated in the Manual.

    NO Replace the Iono board

    After 8 seconds does the

    flame move to the

    maximum power?

    NODoes the boiler

    goes in block

    after 10 secs?

    YES

    Is the ionization

    electrode dirty,

    wrong regulated or

    damaged? YESClean, regulate or replace

    the ionization elec.

    YES NO

    Does the water flow

    remain low? YESClean the DHW

    exchanger with specific

    products

    Does the water at the tap

    get warm? NO

    The water draw

    off is superior to

    that allowed by

    the boiler?

    ( see the Manual YES Reduce the water draw off at the tapYES

    Reduce the draw off at the

    tap at 5 l/min

    Does the flame modulate

    after some seconds?

    NOCheck the resistance of

    the NTC sensor and

    replace it if necessary

    0C = 33 k20C = 12,5 k60C = 2,5 k80C = 1,3 k

    YES END OF THE DHW TEST CHECK OF THE HEATING

    NO Regulate the room thermostatNO

    Move the selector on

    WINTER with theregulation at maximum

    Does the boiler switch on?

    Does the Room

    Therm. ask forheat?

    YES Create a jumper between 5 and 7 of M10 of the PCB/M,

    if the boiler doesnt switch on replace the PCB/M

    YES NO Regulate the parameterDoes the pump start

    working? NOIs the

    parameter 5

    regulated on the

    value 0?YES Replace the PCB/M

    YESDo the radiators get

    warm?

    NO Check that the taps or thermostatic valves are open

    YES END OF THE TEST

  • 7/30/2019 z Eura Technical 2003 Manuale

    16/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    17/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    18/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    19/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    20/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    21/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    22/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    23/24

  • 7/30/2019 z Eura Technical 2003 Manuale

    24/24