34
X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT Jan W. Hopmans Volker Clausnitzer University of California Davis Dorthe Wildenschild & Annette Mortensen

X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT

X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND TRANSPORT

Jan W. Hopmans Volker ClausnitzerUniversity of California

Davis

Dorthe Wildenschild &

Annette Mortensen

Page 2: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

ISSUES:

• Measurements and modeling of water flow and contaminant transport in soils and groundwater are generally macroscopic (spatial scale range of 1 cm to 1 m or larger);

• Fundamental mechanisms occur at microscopic scales ( micrometer or smaller);

• Improved understanding and model predictions require microscopic approach.

Page 3: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

WE HAVE COME AT CROSS ROADS WITHIN PORE-SCALE FLUID

CONTINUUM,

FOR WHICH MEASUREMENTS AND MODELING APPLY TO IDENTICAL

SPATIAL SCALES

Note: It was Bear (1972) that presumed that any attempt to describe in an exact manner the geometry of pores and solid surfaces inside a porous medium is hopeless.

Page 4: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Detector Plane

Source

X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive and noninvasive measurements of fluid saturation

and concentration at the micro-scale

Pore-scale measurements are being developed so that fundamental processes of flow & transport can be studied at pertinent micro-scale range

AS OPPOSED TO RADIOGRAPHY

(2-dimensional)

Page 5: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Io (x-rays): Intensity (photons/sec) produced by electron ray tube

Bremstrahlung

Characteristic energy levels (Tungsten target)

1.E-5

1.E-4

1.E-3

1.E-2

1.E-1

1.E+0

1.E+1

0 20 40 60 80 100 120

Photon Energy [keV]

Spec

ific

Bea

m In

tens

ity [p

hoto

ns s

ec-1

eV-1

]

at Source

after 3.2 mm Plexiglas

after 3.2 mm Plexiglas + 2 mm H2O + 3 mm GlassPOLYCHROMATIC

Page 6: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Detector Plane

Source

Procedure for 3-D imaging:Cone beam with planar Detector Array;Scan object from many different beam directions;By rotating scanning object;Use reconstruction algorithm to solve for µ(x).

Page 7: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

⎛ ⎞⎜ ⎟⎝ ⎠∫oL

I = I exp - µ(x)dx

µ : linear attenuation coefficient, and is equal to the probability that photon is removed from the beam (by either scattering or absorption). It is a function of energy of x-ray

source

Io

I

L

Page 8: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

R2 = 0.9992

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 20 40 60 80 100

c NaI [mg/ml]

µ [c

m-1

]50 keV

60 keV

70 keV80 keV

⎛ ⎞⎜ ⎟⎝ ⎠∫oL

I = I exp - µ(x)dxAttenuation coefficient is a linear function of

electron density.

In practice:

Conduct a priori calibration to estimate soil

density, water content, or soil

solution concentration

Page 9: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

0

0.5

1

1.5

2

2.5

3

0 0.2 0.4 0.6 0.8 1

Object Depth [cm]

Effe

ctiv

e Li

near

Att

enua

tion

Coe

ffic

ient

[cm-1

]

0

10

20

30

40

50

60

Equi

vale

nt M

onoc

hrom

atic

Bea

m E

nerg

y [k

eV]

[keV]

[cm-1]

BEAM HARDENING

For polychromatic radiation, attenuation decreases with penetration depth, due to selected removal of photons of the more strongly attenuated energy levels, hence variations in

attenuation are biased

Page 10: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Detector:Planar x-ray-sensitive scintillating detector;provides instantaneous 2D radiographic image,that is recorded by CCD camera

Detector Plane

Source

CCD Camera

mirror

Page 11: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Detector Plane

Source

Beam Geometry: Fan beam (2D)Cone beam (3D)Parallel beam (3D- synchrotron

Voxel size controlled by: source and detector sizephoton fluxacquisition time

Page 12: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Example of CMT for nondestructive 3D plant root measurements

Experimental Setup

3D Root Image, showing isolines of attenuation

Heeraman, Hopmans andClausnitzer

Plant &Soil, 1997

Page 13: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Representative Elementary Volume (REV) of glass beads Clausnitzer et al (1999)

Detector Plane

Source

Noninvasive measurement of 3D material attenuation;

Glass bead diameter is 0.5 mm

Spatial resolution: 20 micrometer

Page 14: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

f(α) = φairfair(α) + φglass fglass(α) + φmix fmix(α)

1f dα∞

−∞

=∫

0

5

10

15

20

25

-0.04 -0.02 0 0.02 0.04 0.06 0.08 0.1

α [mm-1]

Rel

ativ

e Fr

eque

ncy

Air Glass

( )air airfφ α

( )glass glassfφ α

( )mixed mixedfφ α

Page 15: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

REV

Representative Elementary Volume (REV) of glass beads (Clausnitzer et al 1999)

0.10

0.15

0.20

0.25

0.30

0.35

0.40

0.45

0.50

0.55

0.60

0.65

0.70

0.75

0 1 2 3 4 5 6

L /d p

Poro

sity

↓REV

centered in pore

centered in solid REV

Page 16: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Pore-scale measurements of solute breakthrough (Clausnitzer et al 2000)

• 5 cm long and 4.76 mm diameter plexiglas flow cell

• After saturation and steady flow rate, 90-minute pulse of 0.1 ml/hr NaI solution was applied

• 3-dimensional scans of 0.44 mm thick slice, about 20 mm below inflow end, were obtained during breakthrough 4.76 mm

5cm

2cm

0.44mm

Page 17: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

CT SCAN of iodide transportSpatial resolution: 20 µm

Nr. of voxels: about 2 million15 scans for a total of 5 hrs

iodide

iodide

4.76 mm

Page 18: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

POTENTIAL FOR WITHIN PORE CONCENTRATION MEASUREMENT

500 micrometer

Page 19: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

SPATIAL DISTRIBUTION OF PORE WATER VELOCITY

Computed from time to peak concentration to pass through each of

17x17 segments

-10

0

10

20

30

40

50

60

0 60 120 180 240 300

Elapsed Time [min]

c NaI

[mg/

ml]

6789

b

-10

0

10

20

30

40

50

60

0 60 120 180 240 300

Elapsed Time [min]

c NaI

[mg/

ml]

310

c

Page 20: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

( , ) ( )poreT A

Mass c t v dAdt= ∫ ∫ x x

Spatial distribution of total mass breakthrough, with decreasing segment size

17 x 17 segments, with 4100 voxels per

segment

Mass balance error: 5%

-10

0

10

20

30

40

50

60

0 60 120 180 240 300

Elapsed Time [min]

c NaI [m

g/m

l]

310

c

Page 21: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Synchrotron-produced x-rays

High photon flux fluence rate (photons mm-2 sec-1);

Although beam is filtered (monochromator), the fluencerate remains very high;

Thereby allowing high spatial resolutions (micrometer);

And fast transient measurements;

Furthermore, monochromatic beam eliminates beam-hardening;

Experimental results can be compared with Lattice-Boltzmann simulations

Page 22: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

ADVANCED PHOTON SOURCE OF ANL, CHICAGO, IL

Page 23: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

,

BOOSTER,elevating electron energy to 7 billion

electron volts (GeV), about equal to speed of light

Storage Ring of about 1,100 m

High brilliance, up to 100 keV

Page 24: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

GeoSoilEnviroCARS-CAT (13) BeamlineAdvanced Photon Source

Argonne National Laboratory

Page 25: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Drainage and inhibition of fine sand (median particle size is about 200

micrometer)

1.5 mm

Study of Flow Rate Effects on Water Distribution

www.aps.a

nl.gov/ap

simage/poro

usmediamain.h

tml

Page 26: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Separate solid from water and air phase, and

estimate interfacial areas

IMAGE PROCESSING

6 mm

Page 27: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Solid Grain

Pore Space

LATTICE BOLTZMANN SIMULATIONS

(Don Zhang et al, Geophys Res Letters, 2000)

Page 28: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

• Unique capabilities (advantages):– Quantitatively incorporates pore-scale physical and

chemical processes– For arbitrarily complex pore space geometries– Allows direct computation of system characteristics

(e.g., permeability, dispersion)

• Unique capabilities (advantages):– Quantitatively incorporates pore-scale physical and

chemical processes– For arbitrarily complex pore space geometries– Allows direct computation of system characteristics

(e.g., permeability, dispersion)

• Links microscale physics to macroscaleprocesses

• Links microscale physics to macroscaleprocesses

LATTICE BOLTZMANN SIMULATIONS

Page 29: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Neutron Radiography& Computed Tomography

Gadolinium control rods

Page 30: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive
Page 31: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

2.0 x2.0 cm triangular aluminum sample holders

Increasing water saturation

Increasing thickness

Page 32: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Attenuation - Saturation

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0 20 40 60 80 100 120 140 160 180

Attenuation

Satu

ratio

n [v

/v%

]

12.3 mm15.4 mm25.4 mm30.7 mm20.1 mm6.8 mm9.0 mm11.0 mm

AttenuationVolumet

ric

Wat

er C

onte

nt 1 cm thick soil sample

2 cm thick

Page 33: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

Fast Neutron Tomography

Page 34: X-RAY MICRO-TOMOGRAPHY OF PORE-SCALE FLOW AND …hopmans.lawr.ucdavis.edu/papers-ppt-zip/xrayCMT-ppt.pdf · X-ray computed micro-tomography (CMT) provides three-dimensional nondestructive

OPPORTUNITIES ? ? ? ? ?

Development of micro tomography capabilities is approaching spatial and time scales that control flow and transport;

Capabilities are becoming such that physical, chemical and biological processes at solid-liquid and liquid-gas interfaces can be measured;

This is especially true for high photon fluxes, such as provided by synchrotron;

THERE ARE PLENTY ! ! ! ! ! ! !