7
X – SERIES REVERSE OSMOSIS SYSTEMS

X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

X – SERIES REVERSE OSMOSIS SYSTEMS

Page 2: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

PRODUCT OVERVIEW

COMPANY OVERVIEW

• Boiler Feedwater• Small Municipalities• Chemical Manufacturing• Electronics Manufacturing• Metal Plating and Finishing • Ink and Dye Production• Ice Production Equipment • Food and Beverage Production• Bottled Water• Deionization Pre–Treatment

Light weight, heavy-duty Fiberglass Membrane Housing(ASME Certified)

UL/CUL Listed Microprocessor Contoller with NEMA 4X rated enclosure

Up to 80% achievable System recovery, dramatically reducing the waste water to the drain.

High grade Steel Construction and heavy-duty Powder Coating to withstand harsh environment.

Variable Frequency drive for 15HP and larger. Optional for 10HP units.

High Efficiency Vertical Stainless Steel Multi-Stage Pump coupled with Super-E (efficient) motors.

AXEON X – Series Membrane Systems utilize reverse osmosis technology to produce high purity water by reducing contaminants such as dissolved minerals, particulates and organic impurities. AXEON X – Series Membrane Systems are engineered using the highest quality components and materials for reliable operation and exceptional performance. Our standard systems are available with product water outputs from 6 – 396 gpm (8,640 – 570,240 gpd).

AXEON X – Series Membrane Systems are offered with a variety of options such as pre– and post–treatment equipment, distribution pumps and integrated controls for a complete water treatment solution. AXEON X – Series Membrane Systems are skid mounted, pre–plumbed and pre–wired allowing for quick installation and start up. A variety of membrane types are available including low energy, brackish, sea water and low fouling, nanofiltration and ultrafiltration. Our engineers are available for consultation and to assist you in designing your next water treatment solution.

The following are just a few of the industrial applications that benefit from the use of an industrial membrane system:

X1 – SERIESX2 – SERIESX3 – SERIES

0 5000 10000 15000 20000 25000 30000 35000 40000FEED TDS (PPM)

INDUSTRIAL X – SERIES SYSTEMSINDUSTRIAL X – SERIES SYSTEMS

In 30 years, AXEON has made its mark on becoming a world leader and preferred partner for the engineering and manufacturing of innovative membrane and filtration systems and components. With our customers at the center of all that we do, we deliver smart solutions and best quality, distinctive products, that are trusted for their reliability and backed by outstanding support. Our dedicated team of professionals go above and beyond to help our customers grow their business with a competitive advantage in their markets. AXEON. The Watermark of Distinction™

Page 3: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

SKID AND FRAME ASSEMBLYMembrane systems are manufactured in a skid frame design for ease of installation with minimum floorspace requirements. AXEON X – Series Membrane Systems are constructed of welded structural carbon steel tubing and finished with corrosion resistant epoxy powder coating. Stainless steel fasteners and hardware is standard for added corrosion resistance.

CARTRIDGE PRE-FILTRATION HOUSINGIntegrated prefiltration is standard on all systems.

SYSTEM PRESSURE PUMPStandard pressure pumps are constructed with 304 / 316 stainless steel housings, as well as impeller and diffuser stage assemblies. Pumps are equipped with TEFC motors and wired for 230 / 460 VAC voltage, and rated for full load, continuous duty.

MEMBRANE HOUSINGSAll systems feature membrane housings constructed of fiberglass reinforced polyester (FRP) with 316 stainless steel side–entry feed and concentrate ports. Standard housings have a white polyurethane finish and are NSF61 rated. ASME code–stamping is available on all membrane housings.

INSTRUMENTATIONAll systems feature a complete instrumentation package for optimal performance monitoring. Each of the following instruments are panel–mounted and pre–wired:

• Pre– and Post–Cartridge Filter Pressure Gauges• Pump Concentrate Pressure Gauges• Reverse Osmosis Inlet Pump Discharge Pressure

Switches• Permeate and Concentrate Electronic Flow Sensors or

Rotameters• Permeate and Feed Conductivity Monitor• Temperature Sensor• Pump Run Hour Meter

MEMBRANE ELEMENTSStandard reverse osmosis membrane elements are high rejection, thin–film composite (TFC) type, in a spiral–wound configuration. Membrane elements are tested and carry a one–year warranty against defects in quality and workmanship.

SYSTEM CONTROLSOperation of the systems are automatically controlled through a comprehensive microprocessor controller housed in a NEMA – 4X industrial electrical enclosure. The control system also includes a pre–wired motor

starter, operator switches, push–buttons, and status alarm indicator lights. Standard systems include the following isolated alarm conditions:

• Low Inlet Pressure• High Pump Discharge Pressure• High TDS

SYSTEM PIPING AND VALVESAll membrane systems are completely pre–plumbed and installation ready. Sch80 PVC is used for all piping and valves under 75 psig operating pressure. Higher pressure piping and valves are constructed of 316 stainless steel for the X2 and X3. The following valves are provided as standard for accurate flow and pressure control and convenient operation:

• Automatic Inlet Valve to Prevent Water Flow through the System During Shutdown

• Pressure Pump Discharge Throttle Valve• Reverse Osmosis Concentrate Valve• Optional Recirculation Valve• Automatic System Flush Valve for Prevention of

Membrane Fouling and Scale Formation• Inlet and Sampling Valves• Individual Membrane Housing Product Sampling

Valves• CIP Ports for Use with Membrane Cleaning System

FEATURES OVERVIEW

AXEON NAMING MATRIX

X-SERIES MODELX2 Brackish Water Model

HOUSING QUANTITY DESIGNATION1 1 Vessel2 2 Vessels3 3 Vessels4 4 Vessels5 5 Vessels6 6 Vessels

MEMBRANE QUANTITY PER HOUSING2 4 Membranes4 4 Membranes

2.5 INCH MEMBRANE DIAMETER

X2 5 2 80

AXEON NAMING MATRIX

X3 5 2 80X-SERIES MODELX3 Seawater Model

HOUSING QUANTITY DESIGNATION1 1 Vessel2 2 Vessels3 3 Vessels4 4 Vessels5 5 Vessels

MEMBRANE QUANTITY PER HOUSING2 2 Membranes

8.0 INCH MEMBRANE DIAMETER

X – SERIES MODELX1 Tap Water ModelX2 Brackish Water ModelX3 Sea Water Model

HOUSING QUANTITY DESIGNATION1 1 Vessel2 2 Vessels3 3 Vessels4 4 Vessels5 5 Vessels6 6 Vessels7 7 Vessels8 8 Vessels9 9 Vessels10 10 Vessels11 12 Vessels12 12 Vessels

MEMBRANE QUANTITY PER HOUSING1 1 Membrane2 2 Membranes3 4 Membranes4 4 Membranes6 6 Membranes

MEMBRANE SIZE80 8.0 Inch Membrane

AXEON NAMING MATRIX

X1 5 2 80

Page 4: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

X1-1180X1-2180X1-3180X1-2280X1-3280X1-4280X1-5280X1-3480X1-4480X1-5480X1-6480X1-5680X1-6680X1-7680X1-8680X1-9680

X1-10680X1-11680X1-12680

0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400

X1 PERMEATE FLOW RATE (GPM)

X1-SERIESAXEON X – SERIES PERMEATE FLOW RATE CHARTS

X2-1180X2-2180X2-3180X2-4180X2-2280X2-3280X2-4280X2-5280X2-3480X2-4480X2-5480X2-6480X2-5680X2-6680X2-7680X2-8680X2-9680

X2-10680X2-11680X2-12680

0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400

X2 PERMEATE FLOW RATE (GPM)

X2-SERIES

X3-1180X3-1280X3-2280X3-3280X3-4280X3-5280X3-3480X3-4480X3-5480X3-6480

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75

X3 PERMEATE FLOW RATE (GPM)

X3-SERIES

SYSTEMSPERMEATE FLOW RATE

GPM GPDX1 – SERIES

X1 – 1180 6 8,640X1 – 2180 12 17,280X1 – 3180 18 25,920X1 – 2280 22 31,680X1 – 3280 33 47,520X1 – 4280 44 63,360X1 – 5280 55 79,200X1 – 3480 66 95,040X1 – 4480 88 126,720X1 – 5480 110 158,400X1 – 6480 132 190,080X1 – 5680 165 237,600X1 – 6680 198 285,120X1 – 7680 231 332,640X1 – 8680 264 380,160X1 – 9680 297 427,680X1–10680 330 475,200X1–11680 363 522,720X1–12680 396 570,240

X2 – SERIESX2 – 1180 5 7,200X2 – 2180 10 14,400X2 – 3180 15 21,600X2 – 4180 20 28,800X2 – 2280 20 28,800X2 – 3280 30 43,200X2 – 4280 40 57,600X2 – 5280 50 72,000X2 – 3480 60 86,400X2 – 4480 80 115,200X2 – 5480 100 144,000X2 – 6480 120 172,800X2 – 5680 150 216,000X2 – 6680 180 259,200X2 – 7680 210 302,400X2 – 8680 240 345,600X2 – 9680 270 388,800

X2 – 10680 300 432,000X2 – 11680 330 475,200X2 – 12680 360 518,400

X3 – SERIESX3 – 1180 3 4,320X3 – 2180 6 8,640X3 – 2280 12 17,280X3 – 3280 18 25,920X3 – 4280 24 34,560X3 – 5280 30 43,200X3 – 3480 36 51,840X3 – 4480 48 69,120X3 – 5480 60 86,400X3 – 6480 72 103,680

800-320-4074 axeonwater.com©2020 AXEON Water TechnologiesMKT – 560 – A

Page 5: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

MODELS X1 – 2280 X1 – 3280 X1 – 4280 X1 – 5280 X1 – 3480 X1 – 4480 X1 – 5480 X1 – 6480

DESIGN

Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass

Feedwater Source† TDS <2,000 ppm

TDS <2,000 ppm

TDS <2,000 ppm

TDS <2,000 ppm

TDS <2,000 ppm

TDS <2,000 ppm

TDS <2,000 ppm

TDS <2,000 ppm

Standard Recovery % 61 70 75 75 75 75 75 75

Recovery with Concentrate Recycle gpm % 80 80 80 N/A N/A N/A N/A N/A

REJECTIONS AND FLOW RATES

Nominal Salt Rejection % 99 99 99 99 99 99 99 99

Permeate Flow Rate (gpm / lpm) 22.00 / 83.00 33.00 / 125.00 44.00 / 167.00 55.00 / 208.00 66.00 / 250.00 88.00 / 333.00 110.00 / 416.00 132.00 / 500.00

Minimum Concentrate Flow Rate (gpm / lpm) 14 / 53 14 / 53 14.6 / 55 18.3 / 69 22 / 83 29 / 111 36.6 / 139 44 / 167

CONNECTIONS

Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT 3 FNPT 3 FNPT 3 FNPT

Permeate Connection (in) 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 1/2 FNPT 2 1/2 FNPT 3 FNPT 3 FNPT

Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT

Clean–in–Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT

Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT

MEMBRANES

Membrane(s) Per Vessel 2 2 2 2 4 4 4 4

Membrane Quantity 4 6 8 10 12 16 20 24

Membrane Size 8040 8040 8040 8040 8040 8040 8040 8040

VESSELS

Vessel Array 1:1 1:1:1 1:1:1:1 2:1:1:1 2:1 2:1:1 3:1:1 3:2:1

Vessel Quantity 2 3 4 5 3 4 5 6

PUMPS

Pump Type

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Motor HP / KW 10 / 7.5 10 / 7.5 10 / 7.5 10 / 7.5 15 / 11 15 / 11 20 / 11 20 / 11

SYSTEM ELECTRICAL

Standard Voltage + Amp Draw208V – 230V, 60Hz, 3PH, 28A – 27A**

208V – 230V, 60Hz, 3PH, 28A – 27A**

208V – 230V, 60Hz, 3PH, 28A – 27A**

208V – 230V, 60Hz, 3PH, 28A – 27A**

208V – 230V, 60Hz, 3PH,

40.5A – 37A**

208V – 230V, 60Hz, 3PH,

40.5A – 37A**

208V – 230V, 60Hz, 3PH,

49A**

208V – 230V, 60Hz, 3PH,

49A**

SYSTEM DIMENSIONS

Approximate Dimensions* L x W x H (in / cm)

112 x 35 x 74 / 284 x 89 x 188

112 x 35 x 74 / 284 x 89 x 188

112 x 35 x 74 / 284 x 89 x 188

112 x 35 x 74 / 284 x 89 x 188

194 x 41 x 78 / 493 x 104 x 198

194 x 41 x 78 / 493 x 104 x 198

194 x 41 x 78 / 493 x 104 x 198

194 x 41 x 84 / 493 x 104 x 213

Approximate Weight (lbs / kg) 1,285 / 583 1,435 / 651 1,585 / 719 1,735 / 787 2,005 / 910 2,275 / 1,032 2,645 / 1,200 2,910 / 1,320

AXEON X1-SERIES REVERSE OSMOSIS SYSTEMS SPECIFICATIONS

Test Parameters: 550 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 100 psi / 6.9 bar Operating Pressure 77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.** Varies with motor manufacturer.

P: 800-320-4074 • W: www.axeonwater.com • A: 40980 County Center Drive, Suite 100, Temecula, CA 92591

Page 6: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

MODELS X2 – 2280 X2 – 3280 X2 – 4280 X2 – 5280 X2 – 3480 X2 – 4480 X2 – 5480 X2 – 6480

DESIGN

Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass

Feedwater Source TDS max (ppm)† 7,000 7,000 7,000 7,000 7,000 7,000 7,000 7,000

Standard Recovery % 58 70 73 73 73 70 70 73

REJECTIONS AND FLOW RATES

Nominal Salt Rejection % 99.8 99.8 99.8 99.8 99.8 99.8 99.8 99.8

Permeate Flow Rate (gpm / lpm) 21.00 / 79.50 31.50 / 119.00 42.00 / 159.00 52.50 / 198.70 63.00 / 238.40 84.00 / 318.00 105.00 / 397.00 126.00 / 477.00

Minimum Concentrate Flow Rate (gpm / lpm) 15 / 57 13.5 / 51 15.3 / 58 19.42 / 73.51 23.3 / 88.20 36 / 136 45 / 170 46.6 / 176.40

CONNECTIONS

Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT 3 FNPT 3 FNPT 3 FNPT

Permeate Connection (in) 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 1/2 FNPT 2 1/2 FNPT 3 FNPT 3 FNPT

Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT

Clean–in–Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT

Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT

MEMBRANES

Membrane(s) Per Vessel 2 2 2 2 4 4 4 4

Membrane Quantity 4 6 8 10 12 16 20 24

Membrane Size 8040 8040 8040 8040 8040 8040 8040 8040

VESSELS

Vessel Array 1:1 1:1:01 2:1:1 2:1:1:1 2:1 2:1:1 3:1:1 3:2:1

Vessel Quantity 2 3 4 5 3 4 5 6

PUMPS

Pump Type

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Vertical Multi–Stage Centrifugal

Pump

Motor HP / KW 15 / 11 15 / 11 25 / 19 25 / 19 25 / 19 40 / 30 40 / 30 50 / 37

SYSTEM ELECTRICAL

Standard Voltage + Amp Draw 460V, 60Hz, 3PH, 19A**

460V, 60Hz, 3PH, 19A**

460V, 60Hz, 3PH, 31A**

460V, 60Hz, 3PH, 31A**

460V, 60Hz, 3PH, 31A**

460V, 60Hz, 3PH, 48.5A**

460V, 60Hz, 3PH, 48.5A**

460V, 60Hz, 3PH, 58.5A**

SYSTEM DIMENSIONS

Approximate Dimensions* L x W x H (in / cm)

112 x 35 x 74 / 284 x 89 x 188

112 x 35 x 74 / 284 x 89 x 188

112 x 35 x 74 / 284 x 89 x 188

112 x 35 x 84 / 284 x 89 x 213

194 x 41 x 78 / 493 x 104 x 198

194 x 41 x 78 / 493 x 104 x 198

194 x 41 x 78 / 493 x 104 x 198

194 x 41 x 84 / 493 x 104 x 213

Approximate Weight (lbs / kg) 2130 / 970 2450 / 1110 3040 / 1380 3340 / 1520 4100 / 1860 4490 / 2040 5280 / 2400 5640 / 2560

AXEON X2-SERIES REVERSE OSMOSIS SYSTEMS SPECIFICATIONS

Test Parameters: 7000 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 350 psi / 24 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.** Varies with motor manufacturer.

P: 800-320-4074 • W: www.axeonwater.com • A: 40980 County Center Drive, Suite 100, Temecula, CA 92591

Page 7: X – SERIES REVERSE OSMOSIS SYSTEMS Brochures/MKT-560-A...• Food and Beverage Production • Bottled Water • Deionization Pre–Treatment Light weight, heavy-duty Fiberglass Membrane

PRODUCT BROCHURE

MODELS X3 – 1280 X3 – 2280 X3 – 3280 X3 – 4280 X3 – 5280

DESIGN

Configuration Single Pass Single Pass Single Pass Single Pass Single Pass

Feedwater Source TDS max (ppm)† 38,000 38,000 38,000 38,000 38,000

Standard Recovery % 30 45 50 50 50

REJECTIONS AND FLOW RATES

Nominal Salt Rejection % 99.8 99.8 99.8 99.8 99.8

Permeate Flow Rate (gpm / lpm) 5.60 / 21.00 11.10 / 42.00 16.70 / 63.00 22.20 / 84.00 27.80 / 105.00

Minimum Concentrate Flow Rate (gpm / lpm) 14 / 53 14 / 53 17 / 64 22 / 83 28 / 106

CONNECTIONS

Feed Connection (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT

Permeate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT

Concentrate Connection (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT

Clean–in–Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT

Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT

MEMBRANES

Membrane(s) Per Vessel 2 2 2 2 4

Membrane Quantity 2 4 6 8 10

Membrane Size 8040 8040 8040 8040 8040

VESSELS

Vessel Array 1 1:1 1:1:1 2:1:1 2:1:1:1

Vessel Quantity 1 2 3 4 5

PUMPS

Pump Type Axial Piston Axial Piston Axial Piston Axial Piston Axial Piston

Motor HP / KW 20 / 15 20 / 15 25 / 19 40 / 30 40 / 30

SYSTEM ELECTRICAL

Standard Voltage + Amp Draw 460V, 60Hz, 3PH, 25.5A

460V, 60Hz, 3PH, 25.5A

460V, 60Hz, 3PH, 31A**

460V, 60Hz, 3PH, 48.5A

460V, 60Hz, 3PH, 48.5A

SYSTEM DIMENSIONS

Approximate Dimensions* L x W x H (in / cm)

144 x 41 x 75 / 366 x 104 x 190

144 x 41 x 75 / 366 x 104 x 190

144 x 41 x 75 / 366 x 104 x 190

144 x 41 x 75 / 366 x 104 x 190

144 x 41 x 85 / 366 x 104 x 216

Approximate Weight (lbs / kg) 2230 / 1060 2660 / 1206 3090 / 1400 3860 / 1750 4220 / 1920

AXEON X3-SERIES REVERSE OSMOSIS SYSTEMS SPECIFICATIONS

Test Parameters: 35,000 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 950 / 65.5 psi bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.** Varies with motor manufacturer.

P: 800-320-4074 • W: www.axeonwater.com • A: 40980 County Center Drive, Suite 100, Temecula, CA 92591