29
1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department Worcester Polytechnic Institute Worcester, Massachusetts funded by US Department of Justice National Institute of Justice

WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

Embed Size (px)

Citation preview

Page 1: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

1

WPI Precision Personnel Location

(PPL) System

Jim DuckworthElectrical and Computer Engineering Department

Worcester Polytechnic Institute

Worcester, Massachusetts

funded by

US Department of JusticeNational Institute of Justice

Page 2: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

2

Outline

�Need for Position Locator

�Development of our PPL System

�Experimental Results

�The new Locator design

�WPI Location and Tracking Workshop

� August 2007

Page 3: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

3

Position-Finding Technology for Emergency Personnel is a Critical Need

�12/3/99: Six firefighters died in a warehouse fire literally within a few feet of safety in Worcester, MA.

�9/11/01: A disaster of far greater magnitude, with some deaths in circumstances similar to the Worcester

warehouse fire

�NFPA: lost/trapped 3rd ranking cause of fatalities

�Current emergency responder escape technology:

� Audio alarms which sound with lack of motion

� Homing devices (Ultrasonic, RF) becoming available

Page 4: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

4

PPL Goal

�A location and tracking system which

� displays locations, paths, and landmarks

(exits, etc.)

� for multiple responders

� in 3 dimensions,

� requiring no pre-installed infrastructure

� and minimal setup

�Must be transparent to users

Page 5: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

5

The PPL Team

Research Assistants� Jack Coyne� Hauke Daempfling� Jason Farmer� Jason Huang� Shashank Kulkarni� Hemish Parikh� Ben Woodacre� Vincent Amendolare� David Holl

Faculty

� David Cyganski

� R. James Duckworth

� Sergey Makarov

� William Michalson

� John Orr

Technician

� Bob Boisse

Page 6: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

6

System Overview

Personnel

Unit

Reference units

Commander

Display

Page 7: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

7

System Requirements

�Fundamental capabilities:

� 3-D location of each user relative to a chosen reference point

� Relative locations among users� Graphical display at the incident command center

� Graphical path information on all users

�Accuracy: +/- 1 ft�Range: 2000 ft

�Number of simultaneous users: 100�Future enhancements:

� Physiological information telemetry

� Integration with stored databases: geographic and structural

Page 8: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

8

Background

Ranging Signal

� Multi-carrier ranging signal

� Typically 50 carriers� Bandwidths of about 25-

200 MHz� Multipath-resistant� Processed by custom

algorithms� Generated digitally

6986143

6085122

4704101

Upper Freq.

(MHz)

Lower Freq.

(MHz)

Band

Page 9: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

9

Spectrally Friendly System

�The spectral footprint of the MC-WB signal can be tailored to avoid existing services

MC-WB

Existing Services

Page 10: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

10

System Overview

Apply new WPI multi-carrier approach to achieve the necessary precision with low bandwidth, flexible spectral footprint

Page 11: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

11

2005 Outdoor Position Tests

Page 12: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

12

Outdoor 2D TDOA results

Our new multicarrier (MC) signal structure and processing approach theoretically provides high accuracy ranging data with low bandwidth and spectral flexibility

The result of the outdoor test proved that our approach achieved high precision results

Only classic radio location algorithms were applied to the new ranging data

Page 13: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

13

But Indoors is not like Outdoors

Metal ceiling and floor decks

Steel building structure

Every metal structure bounces the signal and contributes another solution confusing multipath component

Page 14: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

14

MC/Classic Location Fails in Hi-Multipath

� By April ’06 we repeatedly demonstrated MC/classic method of radio location could not cope with high multipath indoor propagation problems

� There was much gnashing of teeth

� But adversity is the mother of invention……

Page 15: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

15

New end-to-end method developed

By June 2006 we created an entirely new approach to radio location that uses our MC signal structure but abandons any classic component of radio location – it was a breakthrough

Page 16: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

16

Through-wall/High Multipath Demo

Antennas on 3 sides WPI

Civil Eng. Building –

poor

geometry

Antennas

facing directly into

brick walls

No system

training

information or pre-sited

devices

Page 17: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

17

Kaven Hall Geo-lab test site

Demo site is WPI Civil Eng.

Geology Lab in

Kaven Hall

Steel Frame and

concrete block

construction

with heavy equipment and

metal

furnishings

Since metal

sheets block

and reflect radio waves, this is a difficult test!

Page 18: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

18

The command (debug) post

Real-Time-

update display

of location solution and signal integrity

on command

console

Demonstrated

live at WPI’s

Technology Workshop

(August 6-7

2006)

Page 19: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

19

Low Location Error within Building

Blue squares show actual locations

Red arrows point to locator estimates

Page 20: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

20

Modifying Bandwidth

� 410-470MHz

� Middle Slice

� Mean Error

� 20MHz-2.32m

� 30MHz-1.00m

� 40MHz-0.87m

� 50MHz-0.58m

� 60MHz-0.5m

Page 21: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

21

Ant Location on Fire Truck

CP Patch Ants

Page 22: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

22

Antenna Position

� 60MHz BW

� Change of tx

ant height

� Mean Error

� 1.11m

� 0.67m

� 0.98m

� 0.92m

Page 23: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

23

Improvements with Algorithm

� 60MHz BW

� Mean Error

� 0.50m

� 0.37m

Page 24: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

24

New Locator Requirements

� Transmit ranging signal � Up to 150MHz bandwidth

• programmable waveform

� Support 100 locators� Updates each second

� Low power, long battery life, automatic on/off

� Monitor and report environmental status data� Temperature, movement, diagnostics

� Provide distress button� Small size, lightweight

� Provide support for Physiological data

Page 25: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

25

Locator Hardware

Distress Button

Acceler-ometer

Transceiver Module

PC Interface

Temperature Sensor

Micro-processor

RF Hardware Interface

PC Interface

Acceler-ometer

Temp. Sensor

Distress Button

Micro-

processor

Interfaceto RF

Hardware

RF Data

Channel

Page 26: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

26

Digital Waveform Generation

DAC Output at 300 MSPSZoomed to center carriers

Page 27: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

27

Ongoing R & D

� Enhancing and refining location algorithms to further improve accuracy

� New custom hardware accelerator solution under construction will allow real-time operation with multiple transmitters

� Developing and testing new receiver and transmitter hardware � smaller size and weight� lower power consumption (longer battery life)� better performance � multiple transmitter support� work with wider bandwidths in different bands

� Wearable and receiver antenna designs� Extend from 2D to 3D location� Evaluate system in other locations/buildings

� We have made a promising start� We eagerly await new experimental results!

Page 28: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

28

Precision Indoor Location and TrackingTechnology Workshop

� WPI two day workshop - August 2006

� Over 70 researchers/developers from over 40 companies and institutions

� Presentations, Demos, Working Sessions

� Will host new workshop August 2007

Page 29: WPI Precision Personnel Location (PPL) System · 1 WPI Precision Personnel Location (PPL) System Jim Duckworth Electrical and Computer Engineering Department ... PPL Goal A location

29

WPI Precision Personnel Locator

�Acknowledgments

� The rest of the WPI team

� Worcester Fire Department

� The support of the National Institute of

Justice of DOJ

�Thank you!

www.ece.wpi.edu/Research/PPL/