    WinLink 1000Installation and Operation Manual

    Point to Point WirelessProduct FamilyRevision 6

  • 8/14/2019 Winlink1000 Manual

    2/124

  • 8/14/2019 Winlink1000 Manual

    3/124

    WinLink 1000

    Point-to-Point Wireless TDM/IP Revision 6.0

    Installation and Operation Manual

    NoticeThis manual contains information that is proprietary to RADWin Ltd. ("RADWIN"). No

    part of this publication may be reproduced in any form whatsoever without prior written

    approval by RADWIN Ltd.

    Right, title and interest, all information, copyrights, patents, know-how, trade secrets

    and other intellectual property or other proprietary rights relating to this manual and to

    the WinLink 1000 and any software components contained therein are proprietaryproducts of RADWIN protected under international copyright law and shall be and

    remain solely with RADWIN.

    WinLink 1000 is a registered trademark of RADWIN. No right, license, or interest to such

    trademark is granted hereunder, and you agree that no such right, license, or interest

    shall be asserted by you with respect to such trademark.

    You shall not copy, reverse compile or reverse assemble all or any portion of the Manual

    or the WinLink 1000. You are prohibited from, and shall not, directly or indirectly,

    develop, market, distribute, license, or sell any product that supports substantially

    similar functionality as the WinLink 1000, based on or derived in any way from theWinLink 1000. Your undertaking in this paragraph shall survive the termination of this

    Agreement.

    This Agreement is effective upon your opening of the WinLink 1000 package and shall

    continue until terminated. RADWIN may terminate this Agreement upon the breach by

    you of any term hereof. Upon such termination by RADWIN, you agree to return to

    RADWIN the WinLink 1000 and all copies and portions thereof.

  • 8/14/2019 Winlink1000 Manual

    4/124

    For further information contact RADWIN at the address below or contact your local

    distributor.

    International Headquarters RADWIN Ltd32 Habarzel Street

    Tel Aviv 69710 Israel

    Tel: 972-54-766-00-44

    Fax: 972-3-7662918

    E-mail: [email protected]

    U S Headquarters RADWIN Inc900 Corporate Drive

    Mahwah, NJ 07430 USA

    Tel: (201) 529-1100Fax: (201) 529-

    5777

    E-mail: [email protected]

    mailto:[email protected]:[email protected]:[email protected]:[email protected]
  • 8/14/2019 Winlink1000 Manual

    5/124

    Quick Start GuideInstallation of WinLink 1000 should be carried out only by a qualified

    technician. If you are familiar with WinLink 1000, use this guide to

    prepare the units for operation.

    1. Installing WinLink 1000 UnitsODU Package Contents:

    ODU Mast/Wall mounting kit WinLink 1000 Management software installation CD Mounting instructions Spare RJ-45 connector ODU to IDU cable at length ordered (optional)IDU-E Package Contents: IDU-E 110V/240V adaptor For DC model, -48 VDC with 2-pin terminal block connector (green) IDU wall-mounting drilling template Spare RJ-45 connector(Optional) IDU-C Package Contents:

    IDU-C For AC model, 110v/240 VAC with 3-prong connector cable For DC model, -24 VDC or -48 VDC with 3-pin terminal block

    connector (green)

    IDU standard 1-U, 19 carrier rack Spare RJ-45 connector

    Installing WinLink 1000 Units 1

  • 8/14/2019 Winlink1000 Manual

    6/124

    Quick Start Guide WinLink 1000Installation and Operation Manual

    Equipment Required:

    RJ-45 crimp tool (If pre-assembled cable is not used) Drill (for wall mounting only) IDU and ODU grounding cable 13 mm or 1/2socket spanner ODU to IDU cable if not ordered (Outdoor class, CAT-5e, 4 twisted

    pairs)

    Cable ties Laptop running Windows 2000 or Windows XP

    Before the installation1. Install the WinLink 1000 software on the laptop.2. Verify that all equipment and tools are available.

    Performing Installation To install the ODU:

    1. At site A, route the ODU cable from the ODU location (on the roof) tothe IDU location (inside the building). The maximum length is 100m.

    2. Mount the ODU unit to the mast or wall, using the mounting kit.3. Connect the RJ-45 connectors to both ends of the cable, use the

    pinout table and diagram below:

    IDU RJ 45 Wire Color Function ODU RJ 451 White/Green Ethernet (RxN) 1

    Twisted2 Green Ethernet (RxT) 2

    3 White/Orange Ethernet (TxT) 3

    Twisted4 Blue Power (+) 4

    5 White\Blue Power (+) 5

    Twisted6 Orange Ethernet (TxN) 6

    7 White/Brown Power () 7

    Twisted8 Brown Power () 8

    4. Secure the ODU and ground cables to the mast or brackets usingcable ties.

    2 Installing WinLink 1000 Units

  • 8/14/2019 Winlink1000 Manual

    7/124

    WinLink 1000Installation and Operation Manual Quick Start Guide

    5. Repeat the procedure at site B. To align the ODU:

    1. Connect power to the IDU.Do not stand in front of a live outdoor unit.The antenna used for this transmitter must be installed to provide a

    separation distance of at least 200 cm from all persons and must not be

    co-located or operating in conjunction with any other antenna or

    transmitter.

    Warning

    2. Align the site A ODU in the direction of the site B ODU.3. Align the site B ODU in the direction of the site A ODU.4. Alternating between each site, turn each ODU slowly listening to the

    buzzer beep sequence until optimal alignment is achieved.

    5. Secure the site A and site B ODUs to the mast/wall.6. Monitor the link quality for about 15 minutes to verify stability.7. Connect the management station to one of the two IDUs in the link.8. Start the WINLink Manager application.9. Open the installation wizard and follow the installation steps.10.After selection of the radio channel and the link rate, verify that the

    link quality bar in the WinLink manager is within the green range for

    TDM service and within the yellow range for Ethernet service.

    ote Achieve the best possible link quality values. In case of radio link loss,verify the ODU alignment, or change the radio channel in both sides of

    the link. When the radio link resumes continue the installation process.

    Connecting User Equipment To connect user equipment to the IDU:

    1. Connect the user equipment (such as PBX) to the IDU RJ-45 portdesignated Trunk: On the rear panel of the IDU-E. On the front panel of the IDC-C,

    Installing WinLink 1000 Units 3

  • 8/14/2019 Winlink1000 Manual

    8/124

    Quick Start Guide WinLink 1000Installation and Operation Manual

    2. Connect user hub/router or any other compatible device to the IDURJ-45 port designated LAN: On the rear panel of the IDU-E. On the front panel of the IDU-C.

    ote IDU-C has an integrated LAN switch that provide 2 port of 10/100BaseT.The Integrated LAN switch is not support spanning tree.

    The two LAN ports can be connected to 2 separated LAN segments but

    connection of both LAN ports to the same LAN segment will create a loop

    that fluid the network. Therefore, this configuration is prohibited.

    2. Operating WinLink 1000WinLink 1000 requires no operator attention once installed, with the

    exception of occasional monitoring of front panel indicators and statistics

    data. Intervention is only required when WinLink 1000 must be

    configured to its operational requirements or diagnostic tests are

    performed:

    Normal IndicationsUpon turning on WinLink 1000, the PWR LED in the front panel lights to

    indicate that WinLink 1000 is on. The table below shows the correctstatus of the indicators after power-up.

    Indicator Color StatusPWR Green On (only on IDU-E)

    IDU Orange

    Green

    Blinks for short duration during startup

    normal operation

    ODU Green normal operation

    AIR I/F Orange

    Green

    Blinks for short duration during startup

    normal operation

    SERVICE Green normal operation

    OFF when SERVICE selected is Ethernet only

    4 Operating WinLink 1000

  • 8/14/2019 Winlink1000 Manual

    9/124

    WinLink 1000Installation and Operation Manual Quick Start Guide

    TroubleshootingIf the WinLink 1000 is not operational, determine the cause and solution

    from the table below.

    Led Status RemedyPWR Off For the IDU-E, check that AC adapter is connected

    to the IDU and the AC power outlet.

    IDU Orange Check that the IDU/ODU cable is properly wired

    and connected.

    ODU Red Check that the IDU/ODU cable is properly wired

    and connected.

    Orange Complete the installation procedure from the

    management software.

    AIR I/F

    Red Check the ODU Antenna alignment. Check that

    the radio configuration of both site A and site B

    units are the same (channel and SSID).

    Off Check the TDM service configuration in the NMS.

    Orange Check that the system is not in loopback mode.

    Check the site B IDU ports and cables and site B

    external equipment.

    SVC.

    Red Check the site A IDU ports, cables and external

    equipment.

    Operating WinLink 1000 5

  • 8/14/2019 Winlink1000 Manual

    10/124

    Contents

    Chapter 1. Introduction1.1 Overview ..................................................................................................1-1

    Application....................................................................................................... 1-1Features........................................................................................................... 1-1

    1.2 Physical Description..................................................................................1-4Chapter 2. Installation and Setup

    2.1 WinLink 1000 System ...............................................................................2-22.2 Site Requirements and Prerequisites .........................................................2-22.3 Package Contents .....................................................................................2-32.4 Installation and Setup ...............................................................................2-4

    Mounting the ODU ...........................................................................................2-5Connecting the ODU to the IDU ........................................................................2-6Connecting the Power ......................................................................................2-7Installing WinLink 1000 Management Software .................................................2-8Aligning the WinLink 1000 ODUs....................................................................2-11Installing the Link...........................................................................................2-12Connecting the User Equipment .....................................................................2-22

    2.5 TDM Clock Configuration........................................................................2-242.6 PM Monitor .............................................................................................2-27

    Chapter 3. Configuration3.1 Performing Configuration of WinLink 1000 ...............................................3-1

    Configuring Service Parameters ......................................................................3-12Editing the Configuration Parameters .............................................................3-15Changing the Transmit Power.........................................................................3-17Defining the Management Addresses..............................................................3-18

    3.2 Bridge Configuration ..............................................................................3-23Detailed description .......................................................................................3-24ODU Bridge Mode...........................................................................................3-24IDU Aging time...............................................................................................3-25Dry Contact....................................................................................................3-25Configurable Ethernet Mode ...........................................................................3-25Community String ..........................................................................................3-27

    3.3 TDM Clock Configuration........................................................................3-32Installation and Operation Manual i

  • 8/14/2019 Winlink1000 Manual

    11/124

    Table of Contents

    Chapter 4. Operation4.1 Indicators .................................................................................................4-1

    Panel Indicators................................................................................................4-1Connector LED Indicators .................................................................................4-2

    4.2 Operating WinLink 1000 ...........................................................................4-3Turning On WinLink 1000.................................................................................4-3Normal Indications ...........................................................................................4-3Turning Off WinLink 1000 ................................................................................4-4Changing the Password ....................................................................................4-4

    4.3 Managing WinLink 1000 ...........................................................................4-4Resetting WinLink 1000....................................................................................4-7Saving WinLink 1000 Configuration in a File .....................................................4-7Restoring a Configuration File ..........................................................................4-7Displaying the WinLink 1000 Inventory.............................................................4-8

    Chapter 5. Diagnostics and Troubleshooting5.1 Error Detection and Alarms.......................................................................5-15.2 Collecting and Saving Statistics.................................................................5-35.3 Running Diagnostic Loopbacks .................................................................5-7

    Local External Loopback...................................................................................5-8Remote Internal Loopback ................................................................................5-8Remote External Loopback ...............................................................................5-9Local Internal Loopback....................................................................................5-9

    5.4 Troubleshooting .....................................................................................5-105.5 Frequently Asked Questions ...................................................................5-11

    Air Interface ...................................................................................................5-11Management ..................................................................................................5-12Services.......................................................................................................... 5-13Antennas and Cables......................................................................................5-13Competitive ...................................................................................................5-14

    5.6 Technical Support...................................................................................5-14

    Appendix A. Wiring SpecificationsAppendix B. Mast and Wall InstallationAppendix C. Link Budget CalculatorAppendix D. TDM Clock Configuration

    ii WinLink 1000Installation and Operation Manual

  • 8/14/2019 Winlink1000 Manual

    12/124

    Table of Contents

    List of Figures1-1. Typical Application..........................................................................................1-11-2. WinLink 1000 Units .........................................................................................1-42-1. Typical Installation Diagram ............................................................................2-52-2. IDUs connector panels.....................................................................................2-72-3. Login Screen ...................................................................................................2-92-4. Login vial Local Connection Screen................................................................2-102-5. Main Menu ....................................................................................................2-112-6. Beeper Sequence for ODU Alignment.............................................................2-122-7. Link Installation Wizard .................................................................................2-132-8. Password control dialog box .........................................................................2-142-9. Change Link Password...................................................................................2-152-10. Installation Wizard, System dialog box ........................................................2-162-11. Installation Wizard, Channel Select dialog box.............................................2-172-12. Installation Wizard, Channel Select dialog box (Automatic Channel Select

    enabled) ...........................................................................................................2-182-13. Installation Wizard, Channel Select dialog box (Supporting DFS, ETSI standard

    requirement) ....................................................................................................2-192-14. Installation Wizard, Rates dialog box...........................................................2-202-15. Installation Wizard, Services dialog box.......................................................2-212-16. Installation Wizard, Finish Screen ................................................................2-222-17. TDM clock dialog box for T1 IDU.................................................................2-242-18. TDM clock dialog box for E1 IDU .................................................................2-252-19. Performance Monitoring Report window ......................................................2-272-20. Threshold configuration dialog box.............................................................2-293-1. WinLink Manager Main Menu ...........................................................................3-23-2. Configuration Link Wizard...............................................................................3-33-3. Link Configuration, System dialog box ............................................................3-43-4. Encryption password configuration..................................................................3-53-5. Encryption alternative password configuration ................................................3-53-6. Encryption password configuration..................................................................3-63-7. Authentication ERROR message.......................................................................3-63-8. Link Configuration, Channel select dialog box.................................................3-73-9. Link Configuration, Channel select dialog box with Automatic Channel select .3-83-10. Link Configuration, Channel select dialog box with DFS ................................3-93-11. Channel reselection confirmation dialog box...............................................3-10

    Installation and Operation Manual iii

  • 8/14/2019 Winlink1000 Manual

    13/124

    Table of Contents

    3-12. Reselection process.....................................................................................3-103-13. Reselection process "channel not active in list" ............................................3-113-14. Air Interface Rate select Dialog Box .............................................................3-113-15. Service Parameters Dialog Box, E1/T1 Interface...........................................3-133-16. Service Parameters Dialog Box, Ethernet only Interface ................................3-143-17. Configuration Link, Finish screen ................................................................3-153-18. Configuration Dialog Box ............................................................................3-163-19. Changing the Transmit Power......................................................................3-173-20. Configuration, Management ........................................................................3-193-21. Configuration Management Trap Destination............................................3-203-22. Date & Time configuration...........................................................................3-223-23. Manual changing date and time...................................................................3-223-24. Inventory of HeadQuarters ..........................................................................3-233-25. Site configuration dialog box.......................................................................3-243-26. Configurable Ethernet Mode and External alarms input................................3-263-27. Approving the Ethernet configuration..........................................................3-263-28. Login using IP .............................................................................................3-273-29. Login using local connection .......................................................................3-283-30. Community passwords, Read-Read/Write....................................................3-283-31. Change Community access..........................................................................3-293-32. Community String - recovery ......................................................................3-303-33. Alternative Community................................................................................3-313-34. TDM clock dialog box for T1 IDU.................................................................3-323-35. TDM clock dialog box for E1 IDU .................................................................3-334-1. IDU Panels LEDs ..............................................................................................4-14-2. Main Menu, Wireless Link is Active ..................................................................4-54-3. WinLink 1000 Inventory...................................................................................4-85-1. Preferences Dialog Box, Monitor Log tab .........................................................5-45-2. Preferences Dialog Box, Events Log tab ...........................................................5-55-3. Active Alarms Summary...................................................................................5-65-4. Loopbacks Dialog Box .....................................................................................5-75-5. Local External Loopback..................................................................................5-85-6. Remote Internal Loopback...............................................................................5-85-7. Remote External Loopback ..............................................................................5-95-8. Local Internal Loopback...................................................................................5-9

    iv WinLink 1000Installation and Operation Manual

  • 8/14/2019 Winlink1000 Manual

    14/124

    Table of Contents

    List of Tables2-1. Modes of TDM clock......................................................................................2-252-2. Explanation of performance data...................................................................2-282-3. Action of the tool bar button commands .......................................................2-293-1. Modes of TDM clock......................................................................................3-334-1. IDU Panel LEDs ................................................................................................4-24-2. WAN/LAN LEDs................................................................................................4-24-3. TDM Traffic Indicators.....................................................................................4-24-4. WinLink 1000 Indicators at Startup..................................................................4-35-1. WinLink 1000 Alarms and Information Messages .............................................5-25-2. Active Alarms Summary commands .................................................................5-65-3. Troubleshooting with WinLink 1000 LEDs......................................................5-10Table A-1. ODU-IDU Cable Connector Pinout ..........................................................A-1Table A-2. E1/T1 Connector Pinout ........................................................................A-2Table A-3. Fast Ethernet Connector Pinout..............................................................A-2Table A-4. Terminal Block 3-pin -48VDC................................................................A-3Table A-5. Alarm Connector (Dry-Contact) .............................................................A-3

    Installation and Operation Manual v

  • 8/14/2019 Winlink1000 Manual

    15/124

    Overview 1-1

    Chapter 1Introduction1.1OverviewWinLink 1000 is a carrier-class, high capacity, Point-to-Point

    broadband wireless transmission system. WinLink 1000 combines

    legacy TDM and Ethernet services over 2.4GHz, 4.9GHz, and 5.xGHz

    license-exempt bands and is suitable for deployment in FCC, ESTI, orCSA regulated countries. The system provides up to 48 Mbps wireless

    link and supports ranges of up to 80 km (50 miles).

    Application

    Figure 1-1. Typical Application

    FeaturesWireless LinkWinLink 1000 delivers up to 48 Mbps air rate for Ethernet and E1/T1

    traffic. The system supports a variety of spectrum bands and can be

  • 8/14/2019 Winlink1000 Manual

    16/124

    Chapter 1 Introduction WinLink 1000 Installation and Operation Manual

    1-2 Overview

    configured to operate in any channel on the band with a carrier step

    resolution of 5 MHz.

    WinLink 1000 operation complies with ETSI, CSA and the FCC 47CFR

    Part 15 and subpart C and E requirements.

    WinLink 1000 employs Time Division Duplex (TDD) transmission. Thistechnology simplifies the installation and configuration procedure.

    There is no need to plan and to allocate separate channels for the

    uplink and downlink data streams.

    Operation over 2.4GHz, 4.9 GHz, and 5.x GHz bands is not affected by

    harsh weather conditions, such as fog, heavy rain etc.

    LAN InterfaceThe WinLink 1000 LAN port provides 10/100BaseT interfaces with auto

    negotiation and transparent VLAN support. Traffic handling is providedby a MAC-level self-learning bridge.

    TDM InterfaceThe WinLink 1000 TDM interface accepts E1 or T1 traffic, supporting

    the following:

    Unframed operation (E1 and T1) AMI and B8ZS zero suppression (T1).ManagementWinLink 1000 has full local and remote management capabilities. The

    user-friendly SNMP-based management tool provides full end-to-end

    configuration, event log and performance monitoring capabilities.

    Diagnostics and Performance MonitoringWinLink 1000 supports activating local and remote loopbacks on E1/T1

    links.

    WinLink 1000 constantly monitors the data transmission process,

    evaluates received signal strength, and signal quality. It also monitors

    received traffic and frame rate (FPS) for local and remote units.

  • 8/14/2019 Winlink1000 Manual

    17/124

    WinLink 1000Installation and Operation Manual Chapter 1 Introduction

    Physical Description 1-3

    Optional External AntennaWinLink 1000 supports configuration of an external antennas. In this

    configuration, the radio supplies an N-type connector that connects

    through a coax cable to the external antenna.

    An external antenna can extend the range of the link, and in somecases, it might help to reduce environmental interferences. Various

    external antennas are available for the WinLink 1000 operating

    frequencies.

    For example, an optional flat panel 28 dBi external antenna increases

    the operation range of WinLink 1000 up to 80 km (50 miles).

  • 8/14/2019 Winlink1000 Manual

    18/124

    Chapter 1 Introduction WinLink 1000 Installation and Operation Manual

    1-4 Physical Description

    1.2 Physical DescriptionWinLink 1000 system consists of an Outdoor Unit (ODU) and an Indoor

    Unit (IDU). Figure 1-2illustrates a WinLink 1000 unit assembly.

    Figure 1-2. WinLink 1000 Units

    IDU-E

    The IDU-E front panel includes five LEDs that display the status of

    E1/T1 and LAN, wireless link, self-test results, ODU-to-IDU link, and

    power status. For a detailed description of the front panel LEDs, see

    Chapter 4.

    The rear panel of the indoor unit (IDU) includes the power, WAN, LAN

    and E1/T1, and ODU connectors. The rear panel LEDs are described in

    Chapter 4, and the wiring specifications detailed in Appendix A.

    IDU-C

    The IDU-C front panel includes four LEDs that display the status of

    E1/T1and, wireless link, self-test results, and ODU-to-IDU link. For a

    detailed description of the front panel LEDs, see Chapter 4.

  • 8/14/2019 Winlink1000 Manual

    19/124

    WinLink 1000Installation and Operation Manual Chapter 1 Introduction

    Physical Description 1-5

    Technical SpecificationsAir-Interface Technology OFDM

    Frequency Band 2.4002.4835 GHz FCC/ETSI/IC

    2.4162.4835 GHz (Israel)4.940-4.990 GHz FCC

    5.2505.330 GHz FCC/IC

    5.4705.725 GHz FCC/ETSI

    5.7255.850 GHz FCC/IC

    Range Up to 80 km (50 miles) (*)

    Duplexing Method Time Division Duplex (TDD)

    Capacity Configurable up to 48 Mbps

    Modulation OFDM - BPSK, QPSK, 16QAM, 64QAM

    Channel setting

    Resolution

    5 MHz (*)

    Transmitter Power 18 dBm max (*)

    ODU Installation Mast or wall mounting

    LAN Interface PHY IF Up to 2 x 10/100BaseT, auto-sensing (**)Framing/Coding IEEE 802.3/U

    Bridging Self-learning, up to 2K MAC addresses

    Line Impedance 100

    VLAN Support Transparent

    Connector RJ-45

    E1 Interface Data Rate 1, 2, 4 x E1Unframed (Transparent) 2.048 MHz (**)

    Line Interface HDB3Connector RJ-45

    T1 Interface Data Rate 1, 2, 4 x T1Unframed (Transparent) 1.544 MHz (**)

    Line Interface AMI, B8ZS

    Connector RJ-45

  • 8/14/2019 Winlink1000 Manual

    20/124

    Chapter 1 Introduction WinLink 1000 Installation and Operation Manual

    1-6 Physical Description

    Indicators PWR (green) Power statusIDU (green) IDU status

    ODU (green/red) ODU-to-IDU link status

    AIR I/F (green/red) Air Interface status

    SERVICE (green/red) E1/T1 signal status

    Power Source IDU-E 100240 VAC or -48VDC from rackSource IDU-C 100240 VAC via cable & plug, or -24VDC or

    -48VDC from rack (**)

    Power Consumption 10W max IDU-E and ODU

    14W max IDU-C and ODU

    Connector 2-pin for IDU-E

    IDU-C:

    DC ver: 3-pin terminal block

    AC ver: 3-prong plug

    Physical Outdoor Unit ODU) with integrated antennaHeight 305 mm / 12 in

    Width 305 mm / 12 in

    Depth 58 mm / 2.3 in

    Weight 3.3 kg / 7.2 lb

    Indoor Unit IDU-E IDU-CHeight 44 mm / 1.7 in (1U) 43 mm / 1.7 in

    Width 237 mm / 9.3 in 297 mm / 11.5 in

    Depth 170 mm / 6.7 in 450 mm / 17.7 in

    Weight 0.58 kg / 1.4 lb 1.5 kg / 3.3 lb

    Environment Outdoor Unit ODU)Enclosure All-weather case

    Temperature -35C to 60C/-31F to 140F

    Indoor Unit IDU-Eand IDU-C)

  • 8/14/2019 Winlink1000 Manual

    21/124

    WinLink 1000Installation and Operation Manual Chapter 1 Introduction

    Physical Description 1-7

    Temperature -5C to 45C/23F to 113F

    Humidity Up to 90%, non-condensing

    (*) Specification is different per product, for further details refer to the Link Budget

    Calculator

    (**) Specification is different per ordering option

    Antenna Characteristics ***)Band GHz) 2.312-

    2.3870

    2.400-

    2.4835

    4.940-

    4.990

    5.250-

    5.330

    5.4470-

    5.725

    5.725-

    5.850

    Integrated Antenna 1 ftGain 16dBi 16dBi 22dBi 22dBi 22dBi

    Beam width 20 20 N/A 9 9 9

    Polarization Linear Linear Linear Linear Linear

    External antenna 1 ftGain 21 dBi 22 dBi 22 dBi 22 dBi

    Beam width N/A N/A 9 9 9 9

    Polarization Linear Linear Linear Linear

    External Antenna 2 ftGain 24dBi 24dBi 27 dBi 28dBi 28dBi 28dBi

    Beam width 8 8 8 4.5 4.5 4.5

    Polarization Linear Linear Linear Linear Linear Linear

    External Antenna 3 ftGain 32 dBi 32.5 dBi

    Beam width N/A N/A N/A 4.5 N/A 4.5

    Polarization Linear Linear

    (!) Antennas with higher gains are available

    (***) IC related:

    1. This device has been designed to operate with an antenna having a maximumgain of 32.5dBi. Antenna having a higher gain is strictly prohibited per

    regulations of industry Canada. The required antenna impedance is 50.

    2. Operation is subject to the following 2 conditions:a. This device may not cause interference.

  • 8/14/2019 Winlink1000 Manual

    22/124

    Chapter 1 Introduction WinLink 1000 Installation and Operation Manual

    1-8 Physical Description

    b. This device must accept any interference, including interference that maycause undesired operation of the device.

    3. Caution:High power radars are allocated at the follow frequencies ranges:

    5250-5350MHz, 5650-5850MHz, these radars cause interference and/or

    damage to the LELAN device

  • 8/14/2019 Winlink1000 Manual

    23/124

    WinLink 1000 System 2-1

    Chapter 2Installation and SetupThis chapter describes installation and setup procedures for WinLink

    1000 system.

    After installing the unit, refer to Chapter 3for configuration

    instructions and Chapter 4for operation instructions.

    In case a problem is encountered, refer to Chapter 5for test and

    diagnostic instructions.

    Internal settings, adjustment, maintenance, and repairs may beperformed only by a skilled technician who is aware of the hazardsinvolved.Always observe standard safety precautions during installation,operation, and maintenance of this product.The operator of the spread spectrum intentional radiator or, if theequipment is professionally installed, the installer is responsible forensuring that the system is used exclusively for fixed, point-to-pointoperations . The instruction manual furnished with the intentionalradiator shall contain language in the installation instructionsinforming the operator and the installer of this responsibility.WinLink 1000 has three types of products:

    Auto channel selection is not supportedPrevious or Future release.

    Auto channel selection supportedUser can enable/disable auto

    channel configuration.

    DFSAuto channel is mandatory.

    Warning

    ote

    Warning

  • 8/14/2019 Winlink1000 Manual

    24/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-2 Package Contents

    2.1 WinLink 1000 SystemWinLink 1000 system comprises the following units:

    Outdoor Unit ODU): The ODU has 2 configurations: ODU withintegrated antenna and ODU with N-Type connector for connection

    to an external antenna. Both ODU types have the same interface to

    the IDU. The ODU with integrated antenna has an enclosed

    aluminum frame with a front sealed plastic cover, containing an

    integrated transceiver with an antenna, RF module, modem and

    standard interfaces.

    ODU includes a power connector that receives -48 VDC and a RJ-45

    for Ethernet traffic from the indoor unit (IDU).

    The ODU is attached to a mast using a special mounting kit, which

    is supplied with the unit.

    Indoor Unit IDU): There are two types of IDU cages. IDU-E that is aplastic box of x 19 in. and IDU-C that is based on a metal 19in.

    box address the carrier-class applications. IDU is the interface unit

    between the ODU and the user. It converts 100240 VAC to

    -48VDC, and feeds the ODU by it. The IDU does not store any

    configuration data. Therefore, there is no need for additional

    configuration of the WinLink 1000 system when replacing an IDU.

    2.2 Site Requirements and PrerequisitesFor the IDU, allow at least 90 cm (36 in) of frontal clearance for

    operating and maintenance accessibility. Allow at least 10 cm (4 in)

    clearance at the rear of the unit for signal lines and interface cables.

    The ambient operating temperature should be 45C to 60C/-49F to

    140F (ODU), or -5C to 45C/23F to 113F (IDU) at a relative humidity

    of up to 90%, non-condensing.

    Before starting the installation, use the Link Budget Calculator utility to

    calculate expected performance of the link. You can vary parameter

    inputs to the calculator to determine the optimum system

    configuration. The utility is described in Appendix C.

  • 8/14/2019 Winlink1000 Manual

    25/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-3

    2.3 Package ContentsThe WinLink 1000 packages include the following items:

    ODU Package Containing:

    ODU

    Mast/Wall mounting kit plus mounting instructions

    WinLink 1000 Manager installation CD

    Spare RJ-45 Connector

    IDU-E Package Contents:

    IDU-E

    110V/240V adaptor

    IDU wall-mounting drilling template

    Spare RJ-45 connector

    (Optional) IDU-C Package Contents:

    IDU-C

    For AC model, 110v/240 VAC with 3-prong connector cable

    For DC model, 24VDC or -48 VDC with 3-pin terminal blockconnector (green)

    IDU standard 1-U, 19 carrier rack

    Spare RJ-45 connector

    External antenna (if ordered)

    ODU/IDU Cable at length ordered (optional)

  • 8/14/2019 Winlink1000 Manual

    26/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-4 Installation and Setup

    2.4 Installation and SetupPhysical installation of the WinLink 1000 system installation includes

    the following steps:

    1. Installing ODU at both sites of the link.

    2. Installing ODU cable and connecting ODU to IDU at both sites.

    3. Connecting power.

    4. Installing the management program on the network management

    station.

    5. Aligning the ODUs.

    6. Running the Installation wizard from the management program.

    7. Connecting user equipment to the local and remote IDUs.

  • 8/14/2019 Winlink1000 Manual

    27/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-5

    Figure 2-1illustrates a typical installation of WinLink 1000 with an

    external antenna.

    Figure 2-1. Typical Installation Diagram

    Mounting the ODUThe ODU is the transmitting and receiving element of the WinLink 1000

    system. The ODU can be mounted on a mast or a wall. In both

    installations, the supplied mounting kit is used to secure the ODU.

    Appendix Bdescribes the mast/wall installation instructions.

    A WinLink 1000 link operates in pairs of two WinLink 1000 systems

    with the same configuration. Both systems must be installed, and the

    antennas of the outdoor units must be aligned for maximum

    throughput.

  • 8/14/2019 Winlink1000 Manual

    28/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-6 Installation and Setup

    Prior to connecting cables to the ODU, the protective earth terminalscrew) of the ODU must be connected to an external protective ground

    conductor or to a grounded mast.Only a qualified person using the proper safety equipment shouldclimb the antenna mast. Only trained professional installers should beused when installing or dismantling ODUs and masts.

    To mount the ODU:1. Verify that the ODU mounting brackets are properly grounded.

    2. Attach the ODU unit to the mast. Refer to Appendix Bfor the ODU

    mounting instructions.

    3. Connect the ground cable to the chassis point on the ODU.

    4. Attach the ODU cable to the RJ-45 connector. Refer to Appendix Afor the connector pinout.

    5. Secure the cables to the mast or brackets using provided UV-rated

    cable ties.

    6. Repeat the procedure at the remote site.

    Do not tightly secure the ODU to its mounting brackets, until the

    alignment process of the antenna is complete.

    When installing the ODU, it is important to check that there are no

    direct obstructions in front of the ODU or interference from man-made

    obstacles.

    Connecting the ODU to the IDUThe ODU cable conducts all the user traffic between the IDU and the

    ODU. The ODU cable also provides -48 VDC supply to the ODU. The

    maximum length for one leg of the ODU cable is 100m (328 ft) in

    accordance with10/100BaseT standards.

    ODU cable is supplied pre-assembled with RJ-45 connectors, at thelength specified when ordering. If the ODU cable was not ordered, use

    Cat. 5e shielded cable, the wiring specifications are given in

    Appendix A.

    1. Route the cable from the ODU location into the building, leaving

    some spare. Secure the cable along its path.

    Warning

    ote

  • 8/14/2019 Winlink1000 Manual

    29/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-7

    2. Connect the ODU cable to the RJ-45 connector on the IDU panel

    designated WAN. Figure 2-2illustrates a typical panel of the IDU-E

    and IDU-C.

    Figure 2-2. IDUs connector panels

    Other models may have a different configuration for these panels.

    Connecting the PowerBefore connecting any cable, the protective earth terminals of theAC/DC power must be connected to the protective ground conductorof the mains power cord. Applies to both IDU models.) If you are usingan extension cord power cable) make sure it is grounded as well.Any interruption of the protective grounding) conductor inside oroutside the instrument) or disconnecting of the protective earthterminal can make this unit dangerous. Intentional interruption isprohibited.

    Power is supplied to WinLink 1000 via an external AC/DC converter,

    which receives power from 110240 VAC source and converts it to

    -24VDC or -48 VDC.

    Warning

    ote

  • 8/14/2019 Winlink1000 Manual

    30/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-8 Installation and Setup

    To connect the power IDU-E:1. Connect the 2-pin plug of the AC/DC converter to the 2-pin DC

    power connector on the IDU-E rear panel.

    2. Connect the AC/DC converter 3-prong plug to mains outlet.

    To connect the power for IDU-C: For AC power model, connect the AC cable 3-prong plug to mains

    outlet.

    For DC power model, connect to DC supply on the rack (male

    connector for the terminal block is included).

    Installing WinLink 1000 Management SoftwareWinLink 1000 management application is distributed on CD-ROM as an

    executable file. The application has the following PC requirements:

    Memory: 128 MB RAM

    Disk: 1 GB free hard disk space

    Processor: Pentium 3 or higher

    Network: 10/100BaseT NIC

    Graphics: Card and Monitor that supports 1024768 screen

    resolution with 16 bit color

    Operating system: Windows 2000/XP

    Microsoft Explorer 5.01 or later.

    To install the WinLink 1000 management program:1. Insert the CD-ROM into your CD-ROM drive.

    2. If the installation does not start automatically, run *.exe from the

    CD-ROM drive.

    3. Follow the on screen instructions of the installation wizard to

    complete setup of the WinLink 1000 Management program in thedesired location.

    To perform initial setup:1. Power up the site A's IDU (see Connecting the Poweron page 2-7).

    Wait about 1 minute.

    2. Power up the site BIDU.

  • 8/14/2019 Winlink1000 Manual

    31/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-9

    3. Connect the management station to the LAN.

    Any PC running the WinLink 1000 Management application can be used

    to configure WinLink 1000 units.

    To start WinLink 1000 manager:The ODU communicates with the management application using

    SNMPv1 protocol. The protocol defines three types of "passwords"

    called communities. These communities are Read-Only community -

    for retrieving information from the ODU. A Read-Write community to

    configure and control the ODU, and a trap community used by the ODU

    to issue traps. Refer to Chapter 3, Community Stringon page3-1 for

    a complete description.

    1. From the Startmenu, point to Programs, point to WinLink 1000Manager, and then click WinLink 1000 Manager.

    The password/IP request dialog appears.

    Figure 2-3. Login Screen

    2. Select the suitable option for the IP Address field:

    Enter the IP address of the ODU default value 10.0.0.120.

    The IP address is defined later during link configuration.

    (optional) If user is connected directly to the IDU LAN port, use

    the adjacent list arrow to select Local Connection.

    ote

    ote

  • 8/14/2019 Winlink1000 Manual

    32/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-10 Installation and Setup

    Figure 2-4. Login vial Local Connection Screen

    3. Enter the password

    Default password admin(see Chapter 4 for Changing thePassword)

    The WinLink 1000 Manager Main menu is displayed (see

    Figure 2-5).

  • 8/14/2019 Winlink1000 Manual

    33/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-11

    Figure 2-5. Main Menu

    Aligning the WinLink 1000 ODUsPerform the WinLink 1000 ODU alignment using the Buzzers located

    inside the ODUs. Alignment of a WinLink 1000 link must be performed

    by two people simultaneously, at site Aand at site B. To align the ODUs via ODU Buzzer:

    1. Verify that power is connected to the IDUs at both sites.

    Do not stand in front of a live radio terminal.

    2. Align the site A ODU in the direction of the site B ODU.

    3. Align the site B ODU in the direction of the site A ODU

    4. Alternating between each site, turn each ODU slowly while listening

    to the buzzer beep sequence for the Best Signal sound, until

    optimal alignment is achieved.

    Warning

  • 8/14/2019 Winlink1000 Manual

    34/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-12 Installation and Setup

    5. Secure the site Aand site B ODUs to the mast/wall.6. Monitor the link quality for about 15 minutes to verify stability.

    Buzzer Sequence =buzzer on=buzzer off

    Description

    Best Signal so far

    Signal quality increased

    No change in signal

    Signal quality decreased

    No air link

    Figure 2-6. Beeper Sequence for ODU Alignment

    Installing the LinkInstallation and definition of all parameters are applied to both sides of

    the link.

    To install the link:1. Verify that the management station is properly connected to the

    same LAN as the IDU, and the WinLink 1000 Manager application is

    running.

    2. In the toolbar, click the LinkInstallationbutton.The Installation wizard opens, (see Figure 2-7).

  • 8/14/2019 Winlink1000 Manual

    35/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-13

    Figure 2-7. Link Installation Wizard

    3. Click Next.

    The Password control dialog box opens (see Figure 2-8).

    From Version 1.400 on, the links support AES128 encryptions.

  • 8/14/2019 Winlink1000 Manual

    36/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-14 Installation and Setup

    .

    Figure 2-8. Password control dialog box

    4. If you wish to change the present password, click Change

    If this is the first time initiating an installation on a new link, the

    user must change the pre-defined, default Link Password. The

    wizard will automatically pop up a message to inform you.

    Click OK to open the Change Link Password dialog box (see

    Figure 2-9).

  • 8/14/2019 Winlink1000 Manual

    37/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-15

    Figure 2-9. Change Link Password

    1.Enter the new password in the appropriate text fields.

    Please note that the initial default password is wireless-bridge.

    2.Click OK.

    A warning message appears to confirm the change.

    3.Click Yes to change.

    A message appears to confirm a successful change.

    5. Click Next to proceed with the Installation procedure.

    The system dialog box opens (see Figure 2-10)

  • 8/14/2019 Winlink1000 Manual

    38/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-16 Installation and Setup

    Figure 2-10. Installation Wizard, System dialog box

    6. Enter a SSID (System ID) minimum of eight characters. The ID is

    initially factory set.

    Both sites of a link must always have the same number

    7. Enter Link name for the link identification.

    8. Enter a name for site 1.

    9. Enter a name for site 2.

    10.Click Next.The Channel Select dialog box appears (see Figure 2-11for

    previous releases).

    For release 1.1.6 and above refer to Figure 2-12, page 2-18.

    For 5.4GHz DFS according to ETSI standard, refer to Figure 2-13on

    page 2-19.

    otes

    ote

  • 8/14/2019 Winlink1000 Manual

    39/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-17

    Figure 2-11. Installation Wizard, Channel Select dialog box

    11.Select the required operating channel.

    The pull down list shows the frequencies available.

    The Manual option allows you a User defined channel, within the

    system frequency band.

    Selecting a new channel causes the system quality to change. The

    quality bar shows the adjustment until the system finds the best

    quality link.

    The installation of products that support automatic channel selection is

    performed in a user defined channel, called the installation channel.

    After selecting the channel, the list of channels for automatic channel

    selection can be modified.

    ote

  • 8/14/2019 Winlink1000 Manual

    40/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-18 Installation and Setup

    Figure 2-12. Installation Wizard, Channel Select dialog box (Automatic

    Channel Select enabled)

    This feature is for the 5.4GHz ETSI version product only.DFS/TPCDynamic Frequency Select/Transmit Power control: according

    to ETSI standard for the unlicensed band that eliminates interruption of

    the wireless data equipment to the radar service.

    ote

  • 8/14/2019 Winlink1000 Manual

    41/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-19

    Figure 2-13. Installation Wizard, Channel Select dialog box (Supporting DFS,

    ETSI standard requirement)

    12.Click Next.The Rate Select dialog box appears (see Figure 2-14)

    Table 1-1lists throughput rates and capacities.

  • 8/14/2019 Winlink1000 Manual

    42/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-20 Installation and Setup

    Figure 2-14. Installation Wizard, Rates dialog box

    13.Select a suitable air interface rate according to the services

    required.

    14.Click Evaluate.15.A question box pops up, asking if you want to re-evaluate the link.

    Click Yesto change the rate Noto keep the existing rate.Selecting a new rate causes the system quality to change. The

    quality bar shows the adjustment until the system finds the best

    quality link.

    16.Click Next.The Service Parameters dialog box appears (see Figure 2-15).

  • 8/14/2019 Winlink1000 Manual

    43/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    Installation and Setup 2-21

    Figure 2-15. Installation Wizard, Services dialog box

    17.In the Service dialog box, select one of the following:

    E1/T1 Select the E1/T1 field, if you intend to transmit E1/T1

    data and Ethernet data.

    The Ethernet BW field shows the remaining bandwidth in Mbps

    available for Ethernet. The available bandwidth depends on the

    number of E1/T1 ports selected.

    Select the Ethernet field, if you intend to transmit Ethernet data

    only.

    If you select any of the options except Ethernet only, the wizard opens

    the TDM Clock configuration dialog box, see page 2-24.

    Click Next.The Finish screen appears (see Figure 2-16).

    The Finish screen shows a summary of the link configuration,

    the alignment is complete.

    ote

  • 8/14/2019 Winlink1000 Manual

    44/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-22 Installation and Setup

    Figure 2-16. Installation Wizard, Finish Screen

    18.Click Finishto complete the installation wizard.When the wireless link is established between the site Aandsite Bunits, the Link Status indication bar of the Main menu iswithin the green area.

    19.Verify that the radio signal strength (RSS) in the Main menu is

    according to expected results.

    Connecting the User EquipmentThe IDU-E is a standalone desktop, wall-mounted unit. This unit has

    both front and rear panel connections.

    The optional IDU-C is a standalone rack mounted unit. This unit has

    only front panel connections.

    Figure 2-2illustrates the typical panels of the IDUs.

  • 8/14/2019 Winlink1000 Manual

    45/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    TDM Clock Configuration 2-23

    To connect user equipment to the IDU:1. Connect user E1/T1 traffic to the appropriate IDU panel RJ-45 port

    designated Trunk. Refer to Appendix Afor the connector pinout.2. Connect user hub/router or any other compatible device to the

    appropriate IDU panel RJ-45 port designated LAN. Refer toAppendix Afor the connector pinout.

    IDU-C has an integrated LAN switch that provides 2 ports of

    10/100BaseT. The integrated LAN switch does not support spanning

    tree.

    The two LAN ports can be connected to two separate LAN segments,

    but connection of both LAN ports to the same LAN segment will create

    a loop that floods the network. Therefore, this configuration is

    prohibited.

    ote

  • 8/14/2019 Winlink1000 Manual

    46/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-24 TDM Clock Configuration

    2.5 TDM Clock ConfigurationThe TDM clock feature is enabled in all carrier class IDUs in addition to

    new hardware IDUs. A TDM dialog box will appear where IDU supports

    the clocking configuration feature (see Figure 2-17and Figure 2-18).

    A new master clock configuration option is available in the Link

    Configuration Wizard. The automatic mode selects the clock from the

    first trunk which is working in normal mode (or is configured to loop-

    back maintenance). If a specific trunk is selected this trunk shall be

    used as the system master regardless of the trunks state. The current

    master clock trunk is also displayed.

    Figure 2-17. TDM clock dialog box for T1 IDU

  • 8/14/2019 Winlink1000 Manual

    47/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    TDM Clock Configuration 2-25

    Figure 2-18. TDM clock dialog box for E1 IDU

    This dialog box is activated only after a TDM service was chosen in the

    previous "Service dialog box". In Ethernet only services, the dialog box

    will not be activated.

    This dialog box contains five working modes (see Table 2-1). One

    chooses the appropriate clock mode for the application. Choosing one

    of these modes will set the TDM clock behavior on both sides of the

    link (Headquarter & branch).

    Table 2-1. Modes of TDM clock

    Unit Clock mode User Equipment sideLocal Unit Remote Unit HQ side Branch side1 Transparent Transparent Internal/Recover Internal/Recover

    2 Loop Time Recover Internal Recover

    3 Recover Loop Time Recover Internal

    ote

  • 8/14/2019 Winlink1000 Manual

    48/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-26 PM Monitor

    4 Internal Recover Recover Recover

    5 Recover Internal Recover Recover

    Transparent / Transparent- This mode is identical to the clock methodin previous versions where Winlink1000 transparently regenerates the

    clock from line clock side to Tx clock on the opposite side of the link.The user equipment should be configured as described in the

    embedded table.

    Loop time / RecoverThe local unit receive clock is used as Tx clockon both sides of the link. The user equipment should be set according

    to the embedded table.

    Recover / Loop time- The remote unit receive clock is used as Txclock on both sides. The user equipment should be set according to

    the embedded table.

    Internal / Recover The local unit internal oscillator generates theclock while theremote unit recover this clock. The user equipmentshould be set according to the embedded table.

    Recover / Internal -The remote unit internal oscillator generates theclock while the local unit recovers this clock. The user equipment

    should be set according to the embedded table.

    Chose one of the available modes according to your application.

    The Line code option is used with T1.

  • 8/14/2019 Winlink1000 Manual

    49/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    PM Monitor 2-27

    2.6 PM MonitorThe Performance Monitor Report opens a window (Figure 2-19)

    displaying performance views of each of the interfaces1. Several

    performance data are collected for each of the interface (ES, SES, and

    UAS), Specific data per Interface type (e.g., TX and RX bytes for

    Ethernet). For the Air Interface, user defined thresholds data are

    collected. Refer to Table 2-2, page 2-28and Table 2-3, page 2-29.

    Data are collected and selectively displayed based on three time

    intervals as selected by the Intervalradio buttons: Current (t=0)

    15 minutes Intervals

    Daily.

    Figure 2-19. Performance Monitoring Report window

    1Ethernet performance is not collected in PoE systems.

  • 8/14/2019 Winlink1000 Manual

    50/124

    Chapter 2 Installation and Setup WinLink 1000Installation and Operation Manual

    2-28 PM Monitor

    Table 2-2. Explanation of performance data

    Data type Reported value ExplanationUAS Unavailable

    Seconds

    Seconds in which the interface was out of service.

    ES Error Second The number of seconds in which there was at least an error block.

    Note that notation of an error block is different per interface.

    SES Severe Error

    Second

    The number of seconds in which the service quality is low (the

    actual BBER ratio varies per interface).

    BBE Background

    Block Error

    The number of error block in an interval

    Generic PM

    Data

    Integrity A flag indicating that the data is valid. Note that the PM data is not

    valid if not all the values were stored2

    Max RSL The maximum of the receive signal level (measured in dBm).

    Min RSL The minimum of the receive signal level (measured in dBm).

    Max TSL The maximum of the transmit signal level (measured in dBm)3.

    Min TSL The minimum of the transmit signal level (measured in dBm).

    RSL Threshold 1 This parameter counts the number of seconds in which the RSL is

    below the specified threshold.

    RSL Threshold 2 This parameter counts the number of seconds in which the RSL is

    below the specified threshold.

    TSL Threshold 1 This parameter counts the number of seconds in which the RSL is

    above the specified threshold.

    Air Interface

    PM Data

    BBER Threshold The BBER Threshold value counts the number of seconds in which

    the Background Block Error Ratio (BBER) exceeds the specified

    threshold. Note, that the system is design for excellent quality of

    service with BBER of less then 1%. (at 1% BBER expected TDM BER is

    less than 1E-6.

    Received Bytes The number of Mega bytes received in the specified port within the

    interval

    Ethernet

    Interface PM

    DataTransmitted Bytes The number of Mega bytes received in the specified port within the

    interval.

    2Possible reasons are: Clock changes within the interval and Power up reset

    3The transmit power is fixed. The value can be changed only by user configuration

  • 8/14/2019 Winlink1000 Manual

    51/124

    WinLink 1000Installation and Operation Manual Chapter 2 Installation and Setup

    PM Monitor 2-29

    Table 2-3. Action of the tool bar button commands

    Button ActionGet Data Uploads the selected report from the ODU.

    Save Saves the data in a CSV or Text format for additional analysis.

    Clear Removes the current data from the window.

    Selection

    pane

    Selects the site, interface, and interval to be displayed.

    Threshold Opens the threshold configuration dialog box (Figure 2-20) to set the

    Air Interface thresholds. Note that threshold change is effected

    immediately, but it does not change any historical data.

    Close Closes the Performance Monitor Report window.

    Figure 2-20. Threshold configuration dialog box

  • 8/14/2019 Winlink1000 Manual

    52/124

    Performing Configuration of WinLink 1000 3-1

    Chapter 3ConfigurationThis chapter describes configuration procedures that are performed

    after the link has been installed, synchronized, and the link

    configuration has been performed by wizard.

    WinLink 1000 has three types of products:

    Auto channel selection is not supportedPrevious or Future release.

    Auto channel selection supportedUser can enable/disable auto

    channel configuration.

    DFSAuto channel is mandatory.

    3.1 Performing Configuration of WinLink 1000After installing the link, the system configuration can be altered.

    ote

  • 8/14/2019 Winlink1000 Manual

    53/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-2 Performing Configuration of WinLink 1000

    Installation and definition of all parameters are applied to both sides of

    the link.

    Figure 3-1. WinLink Manager Main Menu

    To change general parameters:1. In the Main menu, click the Link Configurationbutton.2. The Configuration Wizard opens.

    The wizard is used to make configuration changes.

    ote

  • 8/14/2019 Winlink1000 Manual

    54/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-3

    Figure 3-2. Configuration Link Wizard

    3. Click Next.4. The Link Configuration dialog box appears (see Figure 3-3).

  • 8/14/2019 Winlink1000 Manual

    55/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-4 Performing Configuration of WinLink 1000

    Figure 3-3. Link Configuration, System dialog box

    5. In the System dialog box, enter the new data to for the link. All

    fields with a white background can be edited.

    6. Link password (Encryption)

    WinLink 1000 Radio Link is encrypted using Advanced

    Encryption System (AES) with a 128 bit dynamic key. During the

    installation process, a Link Password must be set. An Initial

    encryption key is generated. Each time a link is established, the

    Encryption key is validated. If the validation failed, the link is

    established but no service or configuration is allowed. In this

    state, the user can change the link password of each of the sites.

    In order to change the link password, the user must enter the

    old password. In case of forgotten password, the user may enter

    an alternative password supplied with the product. The

    alternative password is also supplied from customer support

    (after validation of the device serial number or MAC address.

  • 8/14/2019 Winlink1000 Manual

    56/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-5

    The user may change the link password of both sides of the link

    at any time using the Link Configuration Wizard (Figure 3-3).

    An Encryption status icon in the status bar indicates the status

    of the radio link as follows:

    Encrypted Link establishedLink Password Validation failed. The link is encrypted with

    default keys. Service and configuration is unavailable. You

    must change the link password in either site.

    No Encryption an older release is used. No encryption is

    available.

    Figure 3-4. Encryption password configuration

    Figure 3-5. Encryption alternative password configuration

  • 8/14/2019 Winlink1000 Manual

    57/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-6 Performing Configuration of WinLink 1000

    Figure 3-6. Encryption password configuration

    Figure 3-7. Authentication ERROR message

    7. Click Next.The Frequency dialog box appears (see Figure 3-8).

    For releases 1.1.6 and above, refer to Figure 3-9.

    For 5.4GHz DFS according to ETSI standard, refer to Figure 3-10.

    8. Select the required operating channel frequency.

  • 8/14/2019 Winlink1000 Manual

    58/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-7

    Figure 3-8. Link Configuration, Channel select dialog box

    Selecting the Manual option provides the capability to configure the

    channel in 5 MHz steps in the specified band of the product.

    Some of the products support the Automatic channel selection. The

    mode is activated in normal operation mode. During installation the

    user must select the channel manually in order to optimize the antenna

    alignment. Enabling automatic channel selection is perform be clicking

    on the Automatic channel selection check box. After selecting this

    mode, the available channel list is enabled, and the user can select

    which channels are used for the automatic selection (at least twochannels must be selected). The reselect channel button is used to

    change to a new channel from the available channels list.

    ote

  • 8/14/2019 Winlink1000 Manual

    59/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-8 Performing Configuration of WinLink 1000

    By reselecting channel, the radio starts scanning all the channels from

    the available channels list and looks for radio activity in each of the

    channels. It tries to select the optimal channels. If another channels is

    desired the operating channel must be removed from the available

    channel list.

    Some product configurations support the DFS/TPC ETSI Standard. In

    this standard, The Radio is detects Radars and selecting only channels

    were no active Radars. According to the standard, a channel with active

    Radar is prohibited for 30 minutes. Also before any transmission the

    device probe the channel for Radar for a period of 60 seconds before it

    can start transmission.

    Figure 3-9. Link Configuration, Channel select dialog box with Automatic

    Channel select

    ote

  • 8/14/2019 Winlink1000 Manual

    60/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-9

    This feature is for the 5.4GHz ETSI version product only.

    DFS/TPC Dynamic Frequency Select / Transmit Power control ETSI

    standard for the unlicensed band that eliminates interruption of the

    wireless data equipment to the radar service.

    The sign on the configuration Wizard and Status bar indicates thatthe radar detection is on.

    Figure 3-10. Link Configuration, Channel select dialog box with DFS

    Automatic channel selection cannot be unchecked, due to ETSI

    standard requirements.

    A Channel reselection process interrupts the service for the period of

    scanning and re-synchronization of the link. In most of the product

    this process takes few seconds. In products that support DFS/TPC this

    process might take few minute (each channel must be monitored for a

    60 seconds before any transmission can start.

    ote

    ote

  • 8/14/2019 Winlink1000 Manual

    61/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-10 Performing Configuration of WinLink 1000

    Figure 3-11. Channel reselection confirmation dialog box

    Figure 3-12. Reselection process

    Reselection process can take up to few minutes. A bar with activitydisplays the progress of the reselection process.

    ote

  • 8/14/2019 Winlink1000 Manual

    62/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-11

    Figure 3-13. Reselection process "channel not active in list"

    9. Click Next.The Rate Select dialog box appears (see Figure 3-14)

    Table 1-1 lists throughput rates and capacities.

    Figure 3-14. Air Interface Rate select Dialog Box

    10.Select a suitable air interface rate according to the services

    required.

    11.Click Evaluate.

  • 8/14/2019 Winlink1000 Manual

    63/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-12 Performing Configuration of WinLink 1000

    The Evaluate button becomes enabled when a new rate has been

    selected.

    12.A question box pops up, asking if you want to re-evaluate the link.

    Click Yesto change the rate or Noto keep the existing rate.Selecting a new air-interface rate causes the system to change

    its air-interface rate and commence evaluation of the link

    performance at the new air-interface rate. This process of

    evaluation takes a few seconds.

    13.Click Next.The Service Parameters dialog box appears.

    Configuring Service ParametersIn the Service Parameters dialog box configure E1/T1 (x1 or x2) and

    Ethernet parameters.

    To configure E1/T1 and Ethernet:1. In the Service dialog box, select one of the following:

    E1/T1 Select the E1/T1 field, if you intend to transmit E1/T1

    data and Ethernet data.

    The Ethernet BW field shows the remaining bandwidth in Mbps

    available for Ethernet. The available bandwidth depends on the

    number of E1/T1 ports selected.

    Select the Ethernet field, if you intend to transmit Ethernet data

    only

    ote

  • 8/14/2019 Winlink1000 Manual

    64/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-13

    Figure 3-15. Service Parameters Dialog Box, E1/T1 Interface

  • 8/14/2019 Winlink1000 Manual

    65/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-14 Performing Configuration of WinLink 1000

    Figure 3-16. Service Parameters Dialog Box, Ethernet only Interface

    2. Click Next.The Finish screen appears (see Figure 3-17).

    The Finish screen shows a summary of the link configuration.

  • 8/14/2019 Winlink1000 Manual

    66/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-15

    Figure 3-17. Configuration Link, Finish screen

    3. Click Finishto complete the configuration wizard.The Main screen is displayed.

    Editing the Configuration ParametersThe configuration parameters can be edited for each site individually

    without running a wizard.

    To edit the Configuration Parameters:1. Click configurationfrom the main menu.2. Select which site to configure.

    The configuration dialog box opens. (See Figure 3-18)

  • 8/14/2019 Winlink1000 Manual

    67/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-16 Performing Configuration of WinLink 1000

    Figure 3-18. Configuration Dialog Box

    3. In the Configuration dialog box, edit the data to for the link:

    System Tab The contact person and location details can be

    edited.

    Air Interface Tab Used for changing the transmit power

    Management Tab To configure the IP address, Subnet Mask,

    Default Gateway, and the Trap Destination.

    Inventory Tab This screen is read only and cannot be edited

    Date & Time To synchronize date and time to a Network Time

    Protocol version 3 compatible server.

    Backup button Save a backup ini file with current

    configuration.

    Restore button Load the backup ini created by the Backup

    button.

    Install Mode return to Install Mode for the entire link. The

    Buzzer can be muted by selecting the Mute check box before

    click the Install Mode button.

  • 8/14/2019 Winlink1000 Manual

    68/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-17

    4. Click Apply to save the changes.Changing the Transmit Power

    Each ODU can be configured to have a different transmit power level.

    To change the Transmit Power:1. Click configurationfrom the main menu.2. Select which site to configure.

    The configuration dialog box opens.

    3. Click the Air Interface Tab. (See Figure 3-19)

    4. Select the required Transmit Power Level (See Figure 3-19, below).

    Figure 3-19. Changing the Transmit Power

  • 8/14/2019 Winlink1000 Manual

    69/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-18 Performing Configuration of WinLink 1000

    Defining the Management AddressesEach site must be configured separately, first site A then site B.

    To define the Management Addresses:1. Click configurationfrom the main menu.2. Select which site to configure.

    The configuration dialog box opens.

    3. Click the Management Tab (see Figure 3-20).

    4. Enter the IP address of the ODU in the IP address field.

    This screen allow configuration of up to 10 different trap destinations.

    Each destination is defined by an IP address and a UDP port. This

    feature is useful for managing different locations and for running

    several management applications on a single workstation. When

    connected to ODU with firmware older then 1.1.1, a single trap

    destination is displayed, and the trap is always sent to SNMP trap port

    (162). If performing configuration from the WinLink manager, the IP

    address is entered in the login screen (Figure 2-3)

    5. Enter the Subnet Mask.

    6. Enter the Default Gateway.

    7. Enter the Trap Destination. This is the IP address of the PC runningthe management application. The event log will be stored at this

    address.

    ote

  • 8/14/2019 Winlink1000 Manual

    70/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-19

    Figure 3-20. Configuration, Management

  • 8/14/2019 Winlink1000 Manual

    71/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-20 Performing Configuration of WinLink 1000

    Figure 3-21. Configuration Management Trap Destination

    In order to add or change a trap destination, click Edit to open the Trap

    Destination dialog box. Enter the desired IP and port addresses and

    click OK. To clear a trap destination, select the trap and click Clear.

    The Install mode button opens the Main Window for installation mode

    for reinstalling the link.

    The Backup and Restore buttons are for saving and restoring the

    configuration files.

    To set Date and timeThe ODU maintain a time & date value. The time and date value should

    be synchronized to any Network Time Protocol (NTP) version 3

    compatible server1. On power-up the ODU tries to configure the initial

    date and time using an NTP server. If the server IP is not configured or

    is not reachable a default time is set. When configuring the NTP server

    1Windows XP is configured by default as a server.

    otes

    ote

  • 8/14/2019 Winlink1000 Manual

    72/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Performing Configuration of WinLink 1000 3-21

    IP, one should configure also the offset from the Universal Coordinated

    Time (UTC). If there is no server available, the user can set either set

    the time and date or the manager workstation time. Note that manual

    setting is not recommended since reset, power up, or synchronization

    with an NTP server will override the setting.

    The NTP uses UDP port 123. If a firewall is configured between the

    ODU and the NTP server this port must be opened2.

    It can take up to 8 minute for the to synchronize the ODU date and

    time.

    8. Click configurationfrom the main menu.9. Select which site to configure.

    The configuration dialog box opens.

    10.Click the Date & Time Tab (see Figure 3-22).

    2Windows XP command w32tm /stripchart /computer: can be use to

    check the NTP server connectivity

    ote

    ote

  • 8/14/2019 Winlink1000 Manual

    73/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-22 Performing Configuration of WinLink 1000

    Figure 3-22. Date & Time configuration

    11.If entering an address for the NTP Server, click Clear, and then

    enter the new address.

    12.Set the Offset value.

    13.To manually set the date and time, click Change (Figure 3-23) and

    edit the new values.

    Figure 3-23. Manual changing date and time

    To view the inventory HeadQuarters data1. Click configurationfrom the main menu.

  • 8/14/2019 Winlink1000 Manual

    74/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Bridge Configuration 3-23

    2. Select which site to configure.

    The configuration dialog box opens.

    3. Click the Inventory Tab (Figure 3-24).

    This screen is for viewing purposes only.

    Figure 3-24. Inventory of HeadQuarters

    3.2 Bridge ConfigurationBridge configuration is required in various network topologies, such asprotection (1+1) and ring application.

    Detailed descriptionThe bridge configuration parameters are available from the Advanced

    tab of the site configuration dialog box (Figure 3-25). There are two

    parameters:

    ote

  • 8/14/2019 Winlink1000 Manual

    75/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-24 Bridge Configuration

    ODU bridge mode

    IDU Aging time

    Figure 3-25. Site configuration dialog box

    ODU Bridge ModeThis parameter controls the ODU mode with two optional values,

    Bridge Mode (default) (Figure 3-25). In "bridge" mode the ODU

    performs both learning and aging, the aging time of the ODU if

    fixed.

    Hub Mode - in "hub" mode the ODU transparently forward the all

    the packets over the wireless link.

    Changing these parameters requires system reset.ote

  • 8/14/2019 Winlink1000 Manual

    76/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Bridge Configuration 3-25

    IDU Aging timeThis parameter controls the IDU (E and C) aging time.

    The IDU has 2K MAC address learning table. The aging time parameter

    controls the time each MAC address is dropped from the table. Default

    value is 300 (sec).

    Change to these parameters is effective immediately.

    Each side of the link can be configured separately.

    The following list detail common configurations, both sides are

    configured with the same values.

    Standard (Default) Configuration for Ethernet Applications

    IDU-E or IDU-C aging is set to 300 sec (ODU is set to Bridge mode,see Figure 3-25.

    Fast aging mode(for rapid network topology changes)

    IDU-E or IDU-C aging is set to 1 seconds, ODU is set to Hub mode.

    Dry ContactThe IDU-C lets the user configure up to two external alarms using the

    dry contact D-Type connector. The external alarm indicates, in a SNMP

    compatible management system, an alarm generated by on-site

    equipment. For example, smoke detector and low battery alarm can be

    connected to inputs 1 and input 2 (Figure 3-26). The user enables or

    disables each alarm and configures the text that appears in both alarm

    and clear traps. The ODU sends the alarm within a second or less from

    the actual alarm trigger. The delay until the alarm is received by the

    NMS system depends on the network delay.

    Configurable Ethernet ModeThe IDU Ethernet (LAN) port(s) default configuration is auto detect. Inthis mode, the ports detect both line speed (10/100), duplex mode

    (Half/Full) and cable type (Straight/Crossed). If the external equipment

    does not support auto detect or a specific configuration is required,

    the configuration can be selected using the port configuration at the

    advanced tab (figure 3-18).

    ote

    ote

  • 8/14/2019 Winlink1000 Manual

    77/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-26 Bridge Configuration

    Figure 3-26. Configurable Ethernet Mode and External alarms input

    A selection other then "auto detect" disables the cable type detection.

    It is not recommended to configure the port which is used for themanagement connection, since a wrong configuration can cause

    management disconnection. Also wrong configuration might cause

    Ethernet services interruption, refer to Figure 3-27

    Figure 3-27. Approving the Ethernet configuration

    ote

  • 8/14/2019 Winlink1000 Manual

    78/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Bridge Configuration 3-27

    Community StringThe ODU communicates with the management application using

    SNMPv1 protocol. The protocol defines three types of "passwords"

    called communities. These communities are:

    Read-Only community for retrieving information from the ODU.

    Read-Write community to configure and control the ODU.

    Trap community used by the ODU to issue traps.

    Both manager application and ODU use the "public-bru1" for the local

    unit and "public-bru4097" for the remote unit as the factory defaults.

    The management application allows changing these communities. The

    change is performed in a secured (encrypted) manner. Note that there

    is no way to manage the ODU if the read-write or the read community

    were forgotten. In such a case a device specific community must be

    obtained. This community enables connection to the ODU for the

    purpose of setting new community. The device specific community is

    supplied with the device. It can be also obtained from technical

    support. In order to obtain it the serial number or the MAC address of

    the ODU must be supplied.

    Login ScreenThe new read only mode allows accessing the device for monitor andconfiguration display only. No changes to the device are available in

    this mode. Only read-only community is required for this mode.

    Figure 3-28. Login using IP

  • 8/14/2019 Winlink1000 Manual

    79/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-28 Bridge Configuration

    Figure 3-29. Login using local connection

    The "options" button adds two more fields to the login screen. The

    read-only community is required for read only mode login while bothread-only and read-write communities are required for the standard

    login. The device specific community can be used for either read-only

    or read-write communities. The managers set as default the last

    successful login communities.

    Note that, only ODU from release 1.1.2 support changing the

    Community String (Figure 3-30). Older releases support the factory

    default Community String (public-bru1 for both read and read-write).

    Figure 3-30. Community passwords, Read-Read/Write

  • 8/14/2019 Winlink1000 Manual

    80/124

    WinLink 1000Installation and Operation Manual Chapter 3 Configuration

    Bridge Configuration 3-29

    Device Specific Community ChangeA new community must be set when entering the device specific

    community (as the read write community). At the minimum the read-

    write community and read-only community must be set (minimum 5

    characters, the following combinations cannot be used ";", ".", "bru1"

    and "bru4097 ). The values must be confirmed by retyping. The change

    of the trap community is optional using the check box (Figure 3-31).

    Figure 3-31. Change Community access

    Change Communities Change DialogThe community change dialog box is available from the siteconfiguration advanced tab. In these dialog each of the communities

    can be changed. To Change a community, first type the current read-

    write community, the select the type of communities to be change type

    the new community and re-type to confirm. On the first change of the

    read-write community use the "netman" as the current community.

    Also both read-write and read-only communities must be changed.

  • 8/14/2019 Winlink1000 Manual

    81/124

    Chapter 3 Configuration WinLink 1000Installation and Operation Manual

    3-30 Bridge Configuration

    Figure 3-32. Community String - recovery

    Forgotten Community stringIf the read-write community string is not available, an alternative

    community string can be used. The alternative community string is

    unique per ODU. The alternative community string can be used only in

    order to change the communities. The alternative community is

    available with the product. It is recommended to keep it. If both the

    read-write community and the alternative community are not available

    the alternative community can be retrieved by customer support using

    the ODU serial number or MAC address. The serial number can be

    found on the product, the MAC address is di