Upload
others
View
14
Download
2
Embed Size (px)
Citation preview
Reliably Comfortable.TM
HVACmainline.com
MAINLINE ® HVAC
Ductless Heat Pump Product Catalog
Limited 10 year parts & compressor warranty. 3 year replacement warranty. * See warranty certificate for details.
Ductless heat pumps consist of two primary components: The outdoor condensing unit & indoor air handler/evaporator. A refrigerant line set, condensate tubing, as well as electrical wire will need to be connected between the 2 primary components. The condenser is installed
outside the home or structure and the line set/power supply is run from the outdoor unit to individual offices, bedrooms, living rooms, computer/server rooms, and basements, anywhere a conditioned space is desired. A variety of different types of
interior units are then placed in the desired space to condition as needed. Single zone systems condition a single space, multi-zone systems utilize multiple refrigerant lines to provide conditioning in up to 4 separate spaces.
Mainline® ductless heat pumps utilize Inverter Technology to increase energy efficiency. Conventional compressors generally operate by alternately running at maximum capacity or off. Compressors with inverter technology eliminate the frequent cycling with the use of variable frequency to drive the compressor, causing it to operate more at actual system demand. This results in better comfort, efficiency and energy savings.
Not to mention, less wear and tear on the components, increasing overall product life.
OvercoolingPoor temperature controlInefficient use of energy
Minimal temperature fluctuationEfficient use of energy
TEMPERATURE
SET POINT
REACH SETPOINT FASTER
Inverter ACNon-Inverter AC
iFeel function uses the remote to sense surrounding temperatures, adjusting the air flow accordingly for maximum comfort and energy savings.
Frequently, installing ductwork is neither possible or cost-effective. That’s where Mainline® ductless solutions can provide cooling & heating without costly, obtrusive ductwork. They’re a smart alternative to central, forced air HVAC systems and provide an excellent option for remodels, room additions, and as a supplement to existing HVAC systems. Ductless heat pumps also are ideal for a variety of light commercial applications.
Air Handler /Evaporator
Condenser
18K BTU 1 UNIT 2 UNITS
OUTDOOR UNITBBM18H4-OTM18H5-O*
9 9+9
9 9+12
- 12+12
24K BTU 2 UNITS 3 UNITS
OUTDOOR UNITBBM24H4-O TM24H5-O
9+9 12+12 9+9+9 9+12+12
9+12 12+18 9+9+12 9+9+18
9+18 18+18 12+12+12 -
Multi-Zone split systems are designed to provide comfort, uncompromising personal style, quiet operation and Installation flexibility. Simply choose the type of indoor unit and capacity for each room, and the select your system from our matching outdoor/indoor unit combinations chart (below).
30K BTU 2 UNITS 3 UNITS 4 UNITS
OUTDOOR UNITBBM30H4-O
9+9 12+12 9+9+9 12+12+12 9+9+9+9
9+12 12+18 9+9+12 12+12+18 9+9+9+12
9+18 18+18 9+9+18 9+12+18 9+9+12+12
- - 9+12+12 - -
36K BTU 2 UNITS 3 UNITS
OUTDOOR UNIT BBM36H4-O TM36H5-O*
* TM36H5-O ONLY HAS
CONNECTIONS FOR 4 INDOOR UNITS
9+9 12+24 9+9+9 12+12+18 9+9+9+9 9+9+9+24 9+9+9+9+9
9+12 18+18 9+9+12 12+12+24 9+9+9+12 9+9+18+18 9+9+9+9+12
9+18 18+24 9+9+18 12+18+18 9+9+9+18 9+12+12+18 -
9+24 24+24 9+9+24 9+18+18 9+9+12+12 9+12+12+12 -
12+12 12+18 9+12+12 9+12+24 9+9+12+18 12+12+12+12 -
- - 9+12+18 12+12+12 - - -
- - 18+18+18 9+18+24 - - -
42K BTU 2 UNITS 3 UNITS
OUTDOOR UNIT BBM42H3-O TM42H5-O
9+12 12+24 9+9+9 12+12+18 9+9+9+9 9+9+9+24 9+9+9+9+9 9+12+12+12+12
9+18 18+18 9+9+12 12+12+24 9+9+9+12 9+9+12+24 9+9+9+9+12 9+12+12+12+18
9+24 18+24 9+9+18 12+18+18 9+9+9+18 9+9+18+18 9+9+9+9+18 12+12+12+12+12
12+12 24+24 9+9+24 9+18+18 9+9+12+12 9+9+18+24 9+9+9+9+24 9+9+9+18+18
- 12+18 9+12+12 9+12+24 9+9+12+18 9+12+12+18 9+9+9+12+12 9+9+12+12+12
- - 9+12+18 12+12+12 9+12+12+12 9+9+12+24 9+9+9+12+18 9+9+12+12+18
- - 9+18+24 12+18+24 12+12+12+12 9+12+18+18 - -
- - 9+24+24 12+24+24 9+9+12+18 9+18+18+18 - -
- - 18+18+24 18+18+18 12+12+12+18 12+12+12+24 - -
WHAT IS A DUCTLESS HEAT PUMP SYSTEM?
HOW IT WORKS
INVERTER TECHNOLOGY
iFEEL FUNCTION
MULTI ZONE HEAT PUMP SYSTEMS ALLOWABLE COMBINATIONS
COOL FEATURES,HOT TECHNOLOGY.TAKE COMFORT IN MAINLINE®.
4 UNITS* 5 UNITS*
4 UNITS 5 UNITS*
*TM18H5-O Must have a minimum of 2 indoor units connected.
Reliably Comfortable.TM
To learn more visit HVACmainline.com
Reliably Comfortable.TM
HVACmainline.com
MAINLINE ® HVAC
Ductless Heat Pump Product Catalog
Limited 10 year parts & compressor warranty. 3 year replacement warranty. * See warranty certificate for details.
Ductless heat pumps consist of two primary components: The outdoor condensing unit & indoor air handler/evaporator. A refrigerant line set, condensate tubing, as well as electrical wire will need to be connected between the 2 primary components. The condenser is installed
outside the home or structure and the line set/power supply is run from the outdoor unit to individual offices, bedrooms, living rooms, computer/server rooms, and basements, anywhere a conditioned space is desired. A variety of different types of
interior units are then placed in the desired space to condition as needed. Single zone systems condition a single space, multi-zone systems utilize multiple refrigerant lines to provide conditioning in up to 4 separate spaces.
Mainline® ductless heat pumps utilize Inverter Technology to increase energy efficiency. Conventional compressors generally operate by alternately running at maximum capacity or off. Compressors with inverter technology eliminate the frequent cycling with the use of variable frequency to drive the compressor, causing it to operate more at actual system demand. This results in better comfort, efficiency and energy savings.
Not to mention, less wear and tear on the components, increasing overall product life.
OvercoolingPoor temperature controlInefficient use of energy
Minimal temperature fluctuationEfficient use of energy
TEMPERATURE
SET POINT
REACH SETPOINT FASTER
Inverter ACNon-Inverter AC
iFeel function uses the remote to sense surrounding temperatures, adjusting the air flow accordingly for maximum comfort and energy savings.
Frequently, installing ductwork is neither possible or cost-effective. That’s where Mainline® ductless solutions can provide cooling & heating without costly, obtrusive ductwork. They’re a smart alternative to central, forced air HVAC systems and provide an excellent option for remodels, room additions, and as a supplement to existing HVAC systems. Ductless heat pumps also are ideal for a variety of light commercial applications.
Air Handler /Evaporator
Condenser
18K BTU 1 UNIT 2 UNITS
OUTDOOR UNITBBM18H4-OTM18H5-O*
9 9+9
9 9+12
- 12+12
24K BTU 2 UNITS 3 UNITS
OUTDOOR UNITBBM24H4-O TM24H5-O
9+9 12+12 9+9+9 9+12+12
9+12 12+18 9+9+12 9+9+18
9+18 18+18 12+12+12 -
Multi-Zone split systems are designed to provide comfort, uncompromising personal style, quiet operation and Installation flexibility. Simply choose the type of indoor unit and capacity for each room, and the select your system from our matching outdoor/indoor unit combinations chart (below).
30K BTU 2 UNITS 3 UNITS 4 UNITS
OUTDOOR UNITBBM30H4-O
9+9 12+12 9+9+9 12+12+12 9+9+9+9
9+12 12+18 9+9+12 12+12+18 9+9+9+12
9+18 18+18 9+9+18 9+12+18 9+9+12+12
- - 9+12+12 - -
36K BTU 2 UNITS 3 UNITS
OUTDOOR UNIT BBM36H4-O TM36H5-O*
* TM36H5-O ONLY HAS
CONNECTIONS FOR 4 INDOOR UNITS
9+9 12+24 9+9+9 12+12+18 9+9+9+9 9+9+9+24 9+9+9+9+9
9+12 18+18 9+9+12 12+12+24 9+9+9+12 9+9+18+18 9+9+9+9+12
9+18 18+24 9+9+18 12+18+18 9+9+9+18 9+12+12+18 -
9+24 24+24 9+9+24 9+18+18 9+9+12+12 9+12+12+12 -
12+12 12+18 9+12+12 9+12+24 9+9+12+18 12+12+12+12 -
- - 9+12+18 12+12+12 - - -
- - 18+18+18 9+18+24 - - -
42K BTU 2 UNITS 3 UNITS
OUTDOOR UNIT BBM42H3-O TM42H5-O
9+12 12+24 9+9+9 12+12+18 9+9+9+9 9+9+9+24 9+9+9+9+9 9+12+12+12+12
9+18 18+18 9+9+12 12+12+24 9+9+9+12 9+9+12+24 9+9+9+9+12 9+12+12+12+18
9+24 18+24 9+9+18 12+18+18 9+9+9+18 9+9+18+18 9+9+9+9+18 12+12+12+12+12
12+12 24+24 9+9+24 9+18+18 9+9+12+12 9+9+18+24 9+9+9+9+24 9+9+9+18+18
- 12+18 9+12+12 9+12+24 9+9+12+18 9+12+12+18 9+9+9+12+12 9+9+12+12+12
- - 9+12+18 12+12+12 9+12+12+12 9+9+12+24 9+9+9+12+18 9+9+12+12+18
- - 9+18+24 12+18+24 12+12+12+12 9+12+18+18 - -
- - 9+24+24 12+24+24 9+9+12+18 9+18+18+18 - -
- - 18+18+24 18+18+18 12+12+12+18 12+12+12+24 - -
WHAT IS A DUCTLESS HEAT PUMP SYSTEM?
HOW IT WORKS
INVERTER TECHNOLOGY
iFEEL FUNCTION
MULTI ZONE HEAT PUMP SYSTEMS ALLOWABLE COMBINATIONS
COOL FEATURES,HOT TECHNOLOGY.TAKE COMFORT IN MAINLINE®.
4 UNITS* 5 UNITS*
4 UNITS 5 UNITS*
*TM18H5-O Must have a minimum of 2 indoor units connected.
Reliably Comfortable.TM
To learn more visit HVACmainline.com
SINGLE ZONE HEAT PUMP SYSTEMSWALL MOUNT
Slim, stylish and elegant, these ductless wall mount heat pump units from Mainline® feature 16 SEER efficiency, inverter driven compressor technology, LED display, wireless remote control, vertical swing louvers, sleep mode, permanent/washable air filters and utilizes environmentally friendly R410A refrigerant. Each ductless indoor unit is designed to heat or cool a single room, while blending seamlessly into any decor. Available in 115 volt & 208/230 volt models. Cooling operation to 0°, heating to -5°.
Featuring all of the benefits of the 16 SEER models, these 23 SEER ductless heat pumps from Mainline® offer higher efficiency, Energy Star rated, LED display, optional Wi-Fi, and added protection of high & low pressure protection. Available in 208/230 volt models only. Cooling operation to 0°, heating to -5°. Indoor unit compatible with Mainline® multi-zone ductless systems.
• WIRELESS REMOTE CONTROL • INTELLIGENT PRE-HEATING & DEFROST • CONTROL LOCK • MEMORY FUNCTION • IFEEL FUNCTION • LOW VOLTAGE START • AIR FILTERS
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
115 VOLT MODELS BB09HQ1B8A-O BB09HQ1B8A-I 3099-9599 3100-12000 16 10 9
BB09HQ1B8A-O BB12HQ1B8A-I 3 3753-12500 3924-14000 16 9.2 E 9E
208/230 VOLT MODELS – SINGLE PHASE
BB09HQ1C8D-O BB09HQ1C8D-I 3099-9599 3100-12000 16 10 E 9E
BB12HQ1C8D-O BB12HQ1C8D-I 3753-12500 3924-14000 16 9.2 E 9E
BB18HQ1C8D-O BB18HQ1C8D-I 7165-20000 7336-23498 16 9.3 E 9E
BB24HQ1C8D-O BB24HQ1C8D-I 8630-23200 8650-26000 16 9.7 E 9E
PRIM
E 16
SER
IES
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
BB09HQ2A3D-O BB09HQ2A3D-I 3100-9600 1911-12000 23 14.2 10.5
BB12HQ2A3D-O BB12HQ2A3D-I 3100-13000 2400-14000 22 12.5 11E
BB18HQ2A3D -O BB18HQ2A3D-I 6800-2000 7340-23500 20 12.5 10E
BB24HQ2A3D -O BB24HQ2A3D-I 6820-30710 6820-30710 20 12.5 10
BB30HQ2A3D -O BB30HQ2A3D-I 9490-30030 10000-32990 18 10.4 9
BB36HQ2A3D -O BB36HQ2A3D-I 7400-3600 14980-36000 18 8.2 E 9E
TL127000600-L722279 WI-FI KIT
SINGLE ZONE HEAT PUMP SYSTEMSWALL MOUNT
At the top of the single zone list, these single zone ductless heat pumps achieve upwards of an astonishing 38 SEER! These Mainline® systems offer the ultimate in efficiency, with the addition of built in Wi-Fi, crankcase heater, auto fan swing & fan delay functions, upgraded remote control and base pan heater. Models can operate in heating mode as low as -31° ambient temperatures, with 80% heating capacity at -22°. Available in 208/230 volt models only. Indoor unit compatible with Mainline® multi-zone ductless systems.
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
TW09HQ3D6D-O TW09HQ3D6D-I 1535-12996 2388-13648 38 16.5 15
TW12HQ3D6D-O TW12HQ3D6D-I 2900-15354 3071-18766 30.5 15.3 14E
TW18HQ3D6D-O TW18HQ3D6D-I 4094-21837 4094-24566 24.5 13.5 12E
TW24HQ3D6D -O TW24HQ3D6D-I 6800-30700 6800-32000 21.5 13 12PREM
IER 38
SERIE
S
OPTIONAL WALL MOUNT CONTROLLERS
XE71 OPTIONAL WALL MOUNT CONTROLLER
For the ultimate in comfort and flexibility, Mainline® offers multi zone ductless heating & cooling equipment capable of conditioning up to 5 distinct zones of a home or light commercial structure. Several types of indoor units can be installed with this outdoor unit: Wall mounted, ducted, console, floor/ceiling & cassette type indoor units are available for any application. H4/H3 Suffix models can operate in heating mode down to-5° ambient temperatures, while the H5 suffix models can operate as low as -31°, with 80% heating capacity at -22°. Follow installation manual regarding piping & proper indoor unit selection. 208/230 volt –Single phase only.
MULTI ZONE HEAT PUMP SYSTEMS• MULTIPLE ZONES, MULTIPLE INDOOR UNIT CHOICES • INTELLIGENT PRE-HEATING & DEFROST
• CONTROL LOCK • MEMORY FUNCTION • IFEEL FUNCTION
OUTDOOR UNIT NO. ZONES OPERATING RANGE CLG. OPERATING RANGE HTG. CLG. CAP. BTUH HTG. CAP. BTUH SEER NON DUCTED SEER DUCTED VOLTAGE
BBM18H4-O 1-2 0 - 118° -5 – 75° 7000-21000 8500-22600 22 16 208/230-1
BBM24H4-O 2-3 0 - 118° -5 – 75° 7500-33000 7500-27978 21 16 208/230-1
BBM30H4-O 2-4 0 - 118° -5 – 75° 8200-33400 8188-32414 21 16 208/230-1
BBM36H4-O 2-5 0 - 118° -5 – 75° 8900-35800 8871-44356 21 16 208/230-1
BBM42H3-O 2-5 0 - 118° -5 – 75° 8900-40900 8871-46062 21 14.7 208/230-1
TM18H5-O 1-2 0 - 118° -31 – 75° 7000-21000 8500-22600 22 16 208/230-1
TM24H5-O 2-3 0 - 118° -31 – 75° 7500-33000 7500-27978 21 16 208/230-1
TM36H5-O 2-4 0 - 118° -31 – 75° 8900-35800 8871-44356 21 16 208/230-1
TM42H5-O 2-5 0 - 118° -31 – 75° 8900-40900 8871-46062 21 14.7 208/230-1
XE76 OPTIONAL WALL MOUNT DELUXE CONTROLLER
MULTI-ZONE HEAT PUMP SYSTEMS INDOOR UNITS
INDOOR UNIT NO. TYPE NOM. CAPACITY
BBM12HKD-I CASSETTE 12,000
BB18HKD-I CASSETTE 18,000
BBM24HKD-I CASSETTE 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
BB09HQ2A3D-1 WALL MOUNT 9,000
BB12HQ2A3D-I WALL MOUNT 12,000
BB18HQ2A3D-I WALL MOUNT 18,000
BB24HQ2A3D-I WALL MOUNT 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
BBM12HFD-I SLIM DUCT - LOW STATIC 12,000
BBM18HFD-I SLIM DUCT - LOW STATIC 18,000
BBM24HFD-I SLIM DUCT - LOW STATIC 24,000
TMHS09HFD-I SLIM DUCT - MED. STATIC 9,000
TMHS12HFD-I SLIM DUCT - MED. STATIC 12,000
TMHS18HFD-I SLIM DUCT - MED. STATIC 18,000
TMHS24HFD-I SLIM DUCT - MED. STATIC 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
TM09HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 9,000
TM12HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 12,000
TM18HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 18,000
TM24HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
TM09HED-1 MINI CONSOLE 9,000
TM12HED-1 MINI CONSOLE 12,000
TM18HED-1 MINI CONSOLE 18,000
PREF
ERRE
D 23
SER
IES
SINGLE ZONE HEAT PUMP SYSTEMSWALL MOUNT
Slim, stylish and elegant, these ductless wall mount heat pump units from Mainline® feature 16 SEER efficiency, inverter driven compressor technology, LED display, wireless remote control, vertical swing louvers, sleep mode, permanent/washable air filters and utilizes environmentally friendly R410A refrigerant. Each ductless indoor unit is designed to heat or cool a single room, while blending seamlessly into any decor. Available in 115 volt & 208/230 volt models. Cooling operation to 0°, heating to -5°.
Featuring all of the benefits of the 16 SEER models, these 23 SEER ductless heat pumps from Mainline® offer higher efficiency, Energy Star rated, LED display, optional Wi-Fi, and added protection of high & low pressure protection. Available in 208/230 volt models only. Cooling operation to 0°, heating to -5°. Indoor unit compatible with Mainline® multi-zone ductless systems.
• WIRELESS REMOTE CONTROL • INTELLIGENT PRE-HEATING & DEFROST • CONTROL LOCK • MEMORY FUNCTION • IFEEL FUNCTION • LOW VOLTAGE START • AIR FILTERS
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
115 VOLT MODELS BB09HQ1B8A-O BB09HQ1B8A-I 3099-9599 3100-12000 16 10 9
BB09HQ1B8A-O BB12HQ1B8A-I 3 3753-12500 3924-14000 16 9.2 E 9E
208/230 VOLT MODELS – SINGLE PHASE
BB09HQ1C8D-O BB09HQ1C8D-I 3099-9599 3100-12000 16 10 E 9E
BB12HQ1C8D-O BB12HQ1C8D-I 3753-12500 3924-14000 16 9.2 E 9E
BB18HQ1C8D-O BB18HQ1C8D-I 7165-20000 7336-23498 16 9.3 E 9E
BB24HQ1C8D-O BB24HQ1C8D-I 8630-23200 8650-26000 16 9.7 E 9E
PRIM
E 16
SER
IES
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
BB09HQ2A3D-O BB09HQ2A3D-I 3100-9600 1911-12000 23 14.2 10.5
BB12HQ2A3D-O BB12HQ2A3D-I 3100-13000 2400-14000 22 12.5 11E
BB18HQ2A3D -O BB18HQ2A3D-I 6800-2000 7340-23500 20 12.5 10E
BB24HQ2A3D -O BB24HQ2A3D-I 6820-30710 6820-30710 20 12.5 10
BB30HQ2A3D -O BB30HQ2A3D-I 9490-30030 10000-32990 18 10.4 9
BB36HQ2A3D -O BB36HQ2A3D-I 7400-3600 14980-36000 18 8.2 E 9E
TL127000600-L722279 WI-FI KIT
SINGLE ZONE HEAT PUMP SYSTEMSWALL MOUNT
At the top of the single zone list, these single zone ductless heat pumps achieve upwards of an astonishing 38 SEER! These Mainline® systems offer the ultimate in efficiency, with the addition of built in Wi-Fi, crankcase heater, auto fan swing & fan delay functions, upgraded remote control and base pan heater. Models can operate in heating mode as low as -31° ambient temperatures, with 80% heating capacity at -22°. Available in 208/230 volt models only. Indoor unit compatible with Mainline® multi-zone ductless systems.
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
TW09HQ3D6D-O TW09HQ3D6D-I 1535-12996 2388-13648 38 16.5 15
TW12HQ3D6D-O TW12HQ3D6D-I 2900-15354 3071-18766 30.5 15.3 14E
TW18HQ3D6D-O TW18HQ3D6D-I 4094-21837 4094-24566 24.5 13.5 12E
TW24HQ3D6D -O TW24HQ3D6D-I 6800-30700 6800-32000 21.5 13 12PREM
IER 38
SERIE
S
OPTIONAL WALL MOUNT CONTROLLERS
XE71 OPTIONAL WALL MOUNT CONTROLLER
For the ultimate in comfort and flexibility, Mainline® offers multi zone ductless heating & cooling equipment capable of conditioning up to 5 distinct zones of a home or light commercial structure. Several types of indoor units can be installed with this outdoor unit: Wall mounted, ducted, console, floor/ceiling & cassette type indoor units are available for any application. H4/H3 Suffix models can operate in heating mode down to-5° ambient temperatures, while the H5 suffix models can operate as low as -31°, with 80% heating capacity at -22°. Follow installation manual regarding piping & proper indoor unit selection. 208/230 volt –Single phase only.
MULTI ZONE HEAT PUMP SYSTEMS• MULTIPLE ZONES, MULTIPLE INDOOR UNIT CHOICES • INTELLIGENT PRE-HEATING & DEFROST
• CONTROL LOCK • MEMORY FUNCTION • IFEEL FUNCTION
OUTDOOR UNIT NO. ZONES OPERATING RANGE CLG. OPERATING RANGE HTG. CLG. CAP. BTUH HTG. CAP. BTUH SEER NON DUCTED SEER DUCTED VOLTAGE
BBM18H4-O 1-2 0 - 118° -5 – 75° 7000-21000 8500-22600 22 16 208/230-1
BBM24H4-O 2-3 0 - 118° -5 – 75° 7500-33000 7500-27978 21 16 208/230-1
BBM30H4-O 2-4 0 - 118° -5 – 75° 8200-33400 8188-32414 21 16 208/230-1
BBM36H4-O 2-5 0 - 118° -5 – 75° 8900-35800 8871-44356 21 16 208/230-1
BBM42H3-O 2-5 0 - 118° -5 – 75° 8900-40900 8871-46062 21 14.7 208/230-1
TM18H5-O 1-2 0 - 118° -31 – 75° 7000-21000 8500-22600 22 16 208/230-1
TM24H5-O 2-3 0 - 118° -31 – 75° 7500-33000 7500-27978 21 16 208/230-1
TM36H5-O 2-4 0 - 118° -31 – 75° 8900-35800 8871-44356 21 16 208/230-1
TM42H5-O 2-5 0 - 118° -31 – 75° 8900-40900 8871-46062 21 14.7 208/230-1
XE76 OPTIONAL WALL MOUNT DELUXE CONTROLLER
MULTI-ZONE HEAT PUMP SYSTEMS INDOOR UNITS
INDOOR UNIT NO. TYPE NOM. CAPACITY
BBM12HKD-I CASSETTE 12,000
BB18HKD-I CASSETTE 18,000
BBM24HKD-I CASSETTE 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
BB09HQ2A3D-1 WALL MOUNT 9,000
BB12HQ2A3D-I WALL MOUNT 12,000
BB18HQ2A3D-I WALL MOUNT 18,000
BB24HQ2A3D-I WALL MOUNT 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
BBM12HFD-I SLIM DUCT - LOW STATIC 12,000
BBM18HFD-I SLIM DUCT - LOW STATIC 18,000
BBM24HFD-I SLIM DUCT - LOW STATIC 24,000
TMHS09HFD-I SLIM DUCT - MED. STATIC 9,000
TMHS12HFD-I SLIM DUCT - MED. STATIC 12,000
TMHS18HFD-I SLIM DUCT - MED. STATIC 18,000
TMHS24HFD-I SLIM DUCT - MED. STATIC 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
TM09HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 9,000
TM12HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 12,000
TM18HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 18,000
TM24HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
TM09HED-1 MINI CONSOLE 9,000
TM12HED-1 MINI CONSOLE 12,000
TM18HED-1 MINI CONSOLE 18,000
PREF
ERRE
D 23
SER
IES
SINGLE ZONE HEAT PUMP SYSTEMSWALL MOUNT
Slim, stylish and elegant, these ductless wall mount heat pump units from Mainline® feature 16 SEER efficiency, inverter driven compressor technology, LED display, wireless remote control, vertical swing louvers, sleep mode, permanent/washable air filters and utilizes environmentally friendly R410A refrigerant. Each ductless indoor unit is designed to heat or cool a single room, while blending seamlessly into any decor. Available in 115 volt & 208/230 volt models. Cooling operation to 0°, heating to -5°.
Featuring all of the benefits of the 16 SEER models, these 23 SEER ductless heat pumps from Mainline® offer higher efficiency, Energy Star rated, LED display, optional Wi-Fi, and added protection of high & low pressure protection. Available in 208/230 volt models only. Cooling operation to 0°, heating to -5°. Indoor unit compatible with Mainline® multi-zone ductless systems.
• WIRELESS REMOTE CONTROL • INTELLIGENT PRE-HEATING & DEFROST • CONTROL LOCK • MEMORY FUNCTION • IFEEL FUNCTION • LOW VOLTAGE START • AIR FILTERS
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
115 VOLT MODELS BB09HQ1B8A-O BB09HQ1B8A-I 3099-9599 3100-12000 16 10 9
BB09HQ1B8A-O BB12HQ1B8A-I 3 3753-12500 3924-14000 16 9.2 E 9E
208/230 VOLT MODELS – SINGLE PHASE
BB09HQ1C8D-O BB09HQ1C8D-I 3099-9599 3100-12000 16 10 E 9E
BB12HQ1C8D-O BB12HQ1C8D-I 3753-12500 3924-14000 16 9.2 E 9E
BB18HQ1C8D-O BB18HQ1C8D-I 7165-20000 7336-23498 16 9.3 E 9E
BB24HQ1C8D-O BB24HQ1C8D-I 8630-23200 8650-26000 16 9.7 E 9E
PRIM
E 16
SER
IES
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
BB09HQ2A3D-O BB09HQ2A3D-I 3100-9600 1911-12000 23 14.2 10.5
BB12HQ2A3D-O BB12HQ2A3D-I 3100-13000 2400-14000 22 12.5 11E
BB18HQ2A3D -O BB18HQ2A3D-I 6800-2000 7340-23500 20 12.5 10E
BB24HQ2A3D -O BB24HQ2A3D-I 6820-30710 6820-30710 20 12.5 10
BB30HQ2A3D -O BB30HQ2A3D-I 9490-30030 10000-32990 18 10.4 9
BB36HQ2A3D -O BB36HQ2A3D-I 7400-3600 14980-36000 18 8.2 E 9E
TL127000600-L722279 WI-FI KIT
SINGLE ZONE HEAT PUMP SYSTEMSWALL MOUNT
At the top of the single zone list, these single zone ductless heat pumps achieve upwards of an astonishing 38 SEER! These Mainline® systems offer the ultimate in efficiency, with the addition of built in Wi-Fi, crankcase heater, auto fan swing & fan delay functions, upgraded remote control and base pan heater. Models can operate in heating mode as low as -31° ambient temperatures, with 80% heating capacity at -22°. Available in 208/230 volt models only. Indoor unit compatible with Mainline® multi-zone ductless systems.
OUTDOOR UNIT NO. INDOOR UNIT NO. CLG. CAP. BTUH. HTG. CAP. BTUH SEER EER HSPF
TW09HQ3D6D-O TW09HQ3D6D-I 1535-12996 2388-13648 38 16.5 15
TW12HQ3D6D-O TW12HQ3D6D-I 2900-15354 3071-18766 30.5 15.3 14E
TW18HQ3D6D-O TW18HQ3D6D-I 4094-21837 4094-24566 24.5 13.5 12E
TW24HQ3D6D -O TW24HQ3D6D-I 6800-30700 6800-32000 21.5 13 12PREM
IER 38
SERIE
S
OPTIONAL WALL MOUNT CONTROLLERS
XE71 OPTIONAL WALL MOUNT CONTROLLER
For the ultimate in comfort and flexibility, Mainline® offers multi zone ductless heating & cooling equipment capable of conditioning up to 5 distinct zones of a home or light commercial structure. Several types of indoor units can be installed with this outdoor unit: Wall mounted, ducted, console, floor/ceiling & cassette type indoor units are available for any application. H4/H3 Suffix models can operate in heating mode down to-5° ambient temperatures, while the H5 suffix models can operate as low as -31°, with 80% heating capacity at -22°. Follow installation manual regarding piping & proper indoor unit selection. 208/230 volt –Single phase only.
MULTI ZONE HEAT PUMP SYSTEMS• MULTIPLE ZONES, MULTIPLE INDOOR UNIT CHOICES • INTELLIGENT PRE-HEATING & DEFROST
• CONTROL LOCK • MEMORY FUNCTION • IFEEL FUNCTION
OUTDOOR UNIT NO. ZONES OPERATING RANGE CLG. OPERATING RANGE HTG. CLG. CAP. BTUH HTG. CAP. BTUH SEER NON DUCTED SEER DUCTED VOLTAGE
BBM18H4-O 1-2 0 - 118° -5 – 75° 7000-21000 8500-22600 22 16 208/230-1
BBM24H4-O 2-3 0 - 118° -5 – 75° 7500-33000 7500-27978 21 16 208/230-1
BBM30H4-O 2-4 0 - 118° -5 – 75° 8200-33400 8188-32414 21 16 208/230-1
BBM36H4-O 2-5 0 - 118° -5 – 75° 8900-35800 8871-44356 21 16 208/230-1
BBM42H3-O 2-5 0 - 118° -5 – 75° 8900-40900 8871-46062 21 14.7 208/230-1
TM18H5-O 1-2 0 - 118° -31 – 75° 7000-21000 8500-22600 22 16 208/230-1
TM24H5-O 2-3 0 - 118° -31 – 75° 7500-33000 7500-27978 21 16 208/230-1
TM36H5-O 2-4 0 - 118° -31 – 75° 8900-35800 8871-44356 21 16 208/230-1
TM42H5-O 2-5 0 - 118° -31 – 75° 8900-40900 8871-46062 21 14.7 208/230-1
XE76 OPTIONAL WALL MOUNT DELUXE CONTROLLER
MULTI-ZONE HEAT PUMP SYSTEMS INDOOR UNITS
INDOOR UNIT NO. TYPE NOM. CAPACITY
BBM12HKD-I CASSETTE 12,000
BB18HKD-I CASSETTE 18,000
BBM24HKD-I CASSETTE 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
BB09HQ2A3D-1 WALL MOUNT 9,000
BB12HQ2A3D-I WALL MOUNT 12,000
BB18HQ2A3D-I WALL MOUNT 18,000
BB24HQ2A3D-I WALL MOUNT 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
BBM12HFD-I SLIM DUCT - LOW STATIC 12,000
BBM18HFD-I SLIM DUCT - LOW STATIC 18,000
BBM24HFD-I SLIM DUCT - LOW STATIC 24,000
TMHS09HFD-I SLIM DUCT - MED. STATIC 9,000
TMHS12HFD-I SLIM DUCT - MED. STATIC 12,000
TMHS18HFD-I SLIM DUCT - MED. STATIC 18,000
TMHS24HFD-I SLIM DUCT - MED. STATIC 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
TM09HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 9,000
TM12HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 12,000
TM18HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 18,000
TM24HTD-I UNIVERSAL MOUNT (FLOOR CEILING) 24,000
INDOOR UNIT NO. TYPE NOM. CAPACITY
TM09HED-1 MINI CONSOLE 9,000
TM12HED-1 MINI CONSOLE 12,000
TM18HED-1 MINI CONSOLE 18,000
PREF
ERRE
D 23
SER
IES
Reliably Comfortable.TM
HVACmainline.com
MAINLINE ® HVAC
Ductless Heat Pump Product Catalog
Limited 10 year parts & compressor warranty. 3 year replacement warranty. * See warranty certificate for details.
Ductless heat pumps consist of two primary components: The outdoor condensing unit & indoor air handler/evaporator. A refrigerant line set, condensate tubing, as well as electrical wire will need to be connected between the 2 primary components. The condenser is installed
outside the home or structure and the line set/power supply is run from the outdoor unit to individual offices, bedrooms, living rooms, computer/server rooms, and basements, anywhere a conditioned space is desired. A variety of different types of
interior units are then placed in the desired space to condition as needed. Single zone systems condition a single space, multi-zone systems utilize multiple refrigerant lines to provide conditioning in up to 4 separate spaces.
Mainline® ductless heat pumps utilize Inverter Technology to increase energy efficiency. Conventional compressors generally operate by alternately running at maximum capacity or off. Compressors with inverter technology eliminate the frequent cycling with the use of variable frequency to drive the compressor, causing it to operate more at actual system demand. This results in better comfort, efficiency and energy savings.
Not to mention, less wear and tear on the components, increasing overall product life.
OvercoolingPoor temperature controlInefficient use of energy
Minimal temperature fluctuationEfficient use of energy
TEMPERATURE
SET POINT
REACH SETPOINT FASTER
Inverter ACNon-Inverter AC
iFeel function uses the remote to sense surrounding temperatures, adjusting the air flow accordingly for maximum comfort and energy savings.
Frequently, installing ductwork is neither possible or cost-effective. That’s where Mainline® ductless solutions can provide cooling & heating without costly, obtrusive ductwork. They’re a smart alternative to central, forced air HVAC systems and provide an excellent option for remodels, room additions, and as a supplement to existing HVAC systems. Ductless heat pumps also are ideal for a variety of light commercial applications.
Air Handler /Evaporator
Condenser
18K BTU 1 UNIT 2 UNITS
OUTDOOR UNITBBM18H4-OTM18H5-O*
9 9+9
9 9+12
- 12+12
24K BTU 2 UNITS 3 UNITS
OUTDOOR UNITBBM24H4-O TM24H5-O
9+9 12+12 9+9+9 9+12+12
9+12 12+18 9+9+12 9+9+18
9+18 18+18 12+12+12 -
Multi-Zone split systems are designed to provide comfort, uncompromising personal style, quiet operation and Installation flexibility. Simply choose the type of indoor unit and capacity for each room, and the select your system from our matching outdoor/indoor unit combinations chart (below).
30K BTU 2 UNITS 3 UNITS 4 UNITS
OUTDOOR UNITBBM30H4-O
9+9 12+12 9+9+9 12+12+12 9+9+9+9
9+12 12+18 9+9+12 12+12+18 9+9+9+12
9+18 18+18 9+9+18 9+12+18 9+9+12+12
- - 9+12+12 - -
36K BTU 2 UNITS 3 UNITS
OUTDOOR UNIT BBM36H4-O TM36H5-O*
* TM36H5-O ONLY HAS
CONNECTIONS FOR 4 INDOOR UNITS
9+9 12+24 9+9+9 12+12+18 9+9+9+9 9+9+9+24 9+9+9+9+9
9+12 18+18 9+9+12 12+12+24 9+9+9+12 9+9+18+18 9+9+9+9+12
9+18 18+24 9+9+18 12+18+18 9+9+9+18 9+12+12+18 -
9+24 24+24 9+9+24 9+18+18 9+9+12+12 9+12+12+12 -
12+12 12+18 9+12+12 9+12+24 9+9+12+18 12+12+12+12 -
- - 9+12+18 12+12+12 - - -
- - 18+18+18 9+18+24 - - -
42K BTU 2 UNITS 3 UNITS
OUTDOOR UNIT BBM42H3-O TM42H5-O
9+12 12+24 9+9+9 12+12+18 9+9+9+9 9+9+9+24 9+9+9+9+9 9+12+12+12+12
9+18 18+18 9+9+12 12+12+24 9+9+9+12 9+9+12+24 9+9+9+9+12 9+12+12+12+18
9+24 18+24 9+9+18 12+18+18 9+9+9+18 9+9+18+18 9+9+9+9+18 12+12+12+12+12
12+12 24+24 9+9+24 9+18+18 9+9+12+12 9+9+18+24 9+9+9+9+24 9+9+9+18+18
- 12+18 9+12+12 9+12+24 9+9+12+18 9+12+12+18 9+9+9+12+12 9+9+12+12+12
- - 9+12+18 12+12+12 9+12+12+12 9+9+12+24 9+9+9+12+18 9+9+12+12+18
- - 9+18+24 12+18+24 12+12+12+12 9+12+18+18 - -
- - 9+24+24 12+24+24 9+9+12+18 9+18+18+18 - -
- - 18+18+24 18+18+18 12+12+12+18 12+12+12+24 - -
WHAT IS A DUCTLESS HEAT PUMP SYSTEM?
HOW IT WORKS
INVERTER TECHNOLOGY
iFEEL FUNCTION
MULTI ZONE HEAT PUMP SYSTEMS ALLOWABLE COMBINATIONS
COOL FEATURES,HOT TECHNOLOGY.TAKE COMFORT IN MAINLINE®.
4 UNITS* 5 UNITS*
4 UNITS 5 UNITS*
*TM18H5-O Must have a minimum of 2 indoor units connected.
Reliably Comfortable.TM
To learn more visit HVACmainline.com