3
OTP-B Boreal Ductless Single Zone Heat Pump Operating mode • Cooling and heating. Nominal capacity • 9000, 12000, 18000 and 24000 BTU/hr. Voltage • 240/208V, 60 Hz, 1-phase. Indoor unit • High wall installation, dual side connection. • Plastic housing, standard white. • 4-speed cross-flow fan (turbo, high, medium and low). • Smart preheating. • Washable filters. Outdoor unit • Variable speed rotary compressor (INVERTER), with overload protection. • Electronic expansion valve for precise control of refrigerant flow. • Condenser fins covered in a blue hydrophilic coating for improved corrosion resistance. • Large diameter quiet axial-flow fan for more efficient heat exchange. • Drip pan heating cable. • Compressor blanket and preheating technology. • Cooling mode operating ambient temperature: -17 to 43 °C (0.4 to 109.4 °F). • Heating mode operating ambient temperature: -20 to 24 °C (-5 to 75.2 °F). • Installation on epoxy/polyester powder coated adjustable steel wall bracket (optional). Refrigerant • R410A refrigerant, pre-charged for 25 ft. (7.5 m) long connection piping. Connection piping • Minimum piping length of 10 ft. (3 m). • Flared connections. Control • Wireless remote included. • Set temperature: 16 to 30 °C (61 to 86 °F). • Modes: AUTO, COOL, DRY, FAN and HEAT. • SLEEP mode. • Timer. • Auto-Clean function (X-Fan). • Horizontal deflector adjustment. • Temperature display format (°C or °F). • Smart defrosting, starts only when required. • Auto restart in case of power shortage. Warranty Note: All heat pump systems must be installed and registered by a certified Ouellet installer to be covered by the basic warranty. • 5-year basic warranty on parts (labour not included). Sold separately: • Extended warranty from the 1 st to 5 th year, parts and labour. • Extended warranty from the 1 st to 10 th year, parts and labour with system replacement if the compressor fails. Application • Dining room-kitchen, living room, family room, commercial building, office building, condo, restaurant. Features Indoor Unit 22 to 18 SEER Outdoor Unit R410A To Order: OTP-BXXXXXD-I 1 OTP-BXXXXXD-E 1 Indoor Unit Outdoor Unit Note that each unit is individually wrapped. 1 XXXXX = BTU/hr. + OTP-BXXXXXD-I 1 OTP-BXXXXXD-E 1 = OTP-B

OTP-B Boreal Ductless Single Zone Heat Pump - Guillevin · OTP-B Boreal. Ductless Single Zone Heat Pump . Operating mode • Cooling and heating. Nominal capacity ... Connection piping

  • Upload
    lamthu

  • View
    232

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OTP-B Boreal Ductless Single Zone Heat Pump - Guillevin · OTP-B Boreal. Ductless Single Zone Heat Pump . Operating mode • Cooling and heating. Nominal capacity ... Connection piping

OTP-B Boreal Ductless Single ZoneHeat Pump

Operating mode •Coolingandheating.

Nominal capacity •9000,12000,18000and24000BTU/hr.

Voltage •240/208V,60Hz,1-phase.

Indoor unit •Highwallinstallation,dualsideconnection.•Plastichousing,standardwhite. •4-speedcross-flowfan(turbo,high,mediumandlow). •Smartpreheating.•Washablefilters.

Outdoor unit •Variablespeedrotarycompressor(INVERTER),withoverloadprotection. •Electronicexpansionvalveforprecisecontrolofrefrigerantflow. •Condenserfinscoveredinabluehydrophiliccoatingforimprovedcorrosionresistance.

•Largediameterquietaxial-flowfanformoreefficientheatexchange. •Drippanheatingcable. •Compressorblanketandpreheatingtechnology.•Coolingmodeoperatingambienttemperature:-17to43°C(0.4to109.4°F).

•Heatingmodeoperatingambienttemperature:-20to24°C(-5to75.2°F).

• Installationonepoxy/polyesterpowdercoatedadjustablesteelwallbracket(optional).

Refrigerant •R410Arefrigerant,pre-chargedfor25ft.(7.5m)longconnectionpiping.

Connection piping •Minimumpipinglengthof10ft.(3m). •Flaredconnections.

Control •Wirelessremoteincluded. •Settemperature:16to30°C(61to86°F). •Modes:AUTO,COOL,DRY,FANandHEAT. •SLEEPmode. •Timer. •Auto-Cleanfunction(X-Fan). •Horizontaldeflectoradjustment.•Temperaturedisplayformat(°Cor°F). •Smartdefrosting,startsonlywhenrequired. •Autorestartincaseofpowershortage.

Warranty Note: All heat pump systems must be installed and registered by a certified Ouellet installer to be covered by the basic warranty. •5-yearbasicwarrantyonparts(labournotincluded). Soldseparately: •Extendedwarrantyfromthe1stto5thyear,partsandlabour. •Extendedwarrantyfromthe1stto10thyear,partsandlabourwithsystemreplacementifthecompressorfails.

Application •Diningroom-kitchen,livingroom,familyroom,commercialbuilding,officebuilding,condo,restaurant.

Features

Indoor Unit

22 to 18 SEEROutdoor Unit

R410A

To Order:

OTP-BXXXXXD-I1 OTP-BXXXXXD-E1

IndoorUnit OutdoorUnit

Note that each unit is individually wrapped.1 XXXXX=BTU/hr.

+OTP-BXXXXXD-I1

OTP-BXXXXXD-E1

= OTP-B

Page 2: OTP-B Boreal Ductless Single Zone Heat Pump - Guillevin · OTP-B Boreal. Ductless Single Zone Heat Pump . Operating mode • Cooling and heating. Nominal capacity ... Connection piping

OTP-B

Option

Models

Product # Description

OTP-WB3 Adjustablewallbracketforoutdoorunit

Product #1OTP-B09000D-IOTP-B09000D-E

OTP-B12000D-IOTP-B12000D-E

OTP-B18000D-IOTP-B18000D-E

OTP-B24000D-IOTP-B24000D-E

Technical Performance

Cooling capacityNominal W (BTU/hr) 2637(9000) 3517(12000) 5275(18000) 6272(21400)

Min.–max. W (BTU/hr) 1026-2813(3500-9600) 909-3810(3100-13000) 1749-6550(5970-22350) 2813-7327(9600-25000)

Heating capacityNominal W (BTU/hr) 2872(9800) 3810(13000) 5803(19800) 6741(23000)

Min.–max. W (BTU/hr) 645-3224(2200-11000) 703-4103(2400-14000) 1201-6448(4100-22000) 1260-7620(4300-26000)

Used cooling power inputNominal W 620 1000 1500 1780

Min.–max. W 370–1075 365–1080 300–2650 500–2650

Used heating power inputNominal W 750 1200 1650 2100

Min.–max. W 200–900 340–1360 335–2750 400–2750

Used rated input W 1430 1500 2750 2750

Rated current A 7 7.2 12.2 12.2

SEER - 22 20 18 18

HSPF - 9.2 9.2 10 10

EER (BTU/hr)/W 14.2 12 12 12

COP (BTU/hr)/W 14 10.8 12 10.95

Energy Star - 3 3 3 3

Indoor Unit

Dehumidification pt/hr (l/hr) 2.54(2.4) 2.96(2.8) 0.85(0.81) 1.18(1.12)

Air flow volume T/H/M/L2 cfm 306/277/253/218 335/277/253/218 500/459/383/324 589/471/412/353

Sound level T/H/M/L2 dB (A) 42/38/35/32 44/39/36/33 49/44/40/35 53/45/41/37

Fan motor power output W 20 20 20 60

Fan motor RLA A 0.2 0.2 0.32 0.24

Deflector stepper motor power output W 2 2 2.5 3

Weight lb (kg) 22(10) 22(10) 28.7(13) 35.3(16)

Outdoor Unit

Air flow volume cfm 941.6 941.6 1883 2354

Sound level dB (A) 50 52 56 58

Compressor manufacturer - MITSUBISHIELECTRIC(GUANGZHOU)COMPRESSORCO.LTD

Compressor power output W 860 860 1200 1420

Compressor LRA A - - 13.8 18.5

Compressor RLA A 3.2 3.2 4.1 4.9

Fan motor power output W 30 30 60 90

Fan motor RLA A 0.13 0.13 0.28 1.1

Refrigerant volume (R410A) oz (g) 45.864(1300) 45.864(1300) 49.392(1400) 56.448(1600)

Weight lb (kg) 79(36) 88(40) 99(45) 121(55)

Connection Piping

Pre-charge length ft. (m) 25(7.5) 25(7.5) 25(7.5) 25(7.5)

Additional refrigerant charge oz/ft. (g/m) 0.2(18.6) 0.2(18.6) 0.2(18.6) 0.5(46.5)

Liquid pipe outer diameter in. 1/4 1/4 1/4 1/4

Gas pipe outer diameter in. 3/8 3/8 1/2 5/8

Maximum height difference ft. (m) 33(10) 33(10) 33(10) 33(10)

Maximum total length ft. (m) 50(15.2) 66(20.1) 82(25) 82(25)

Drain pipe inner diameter in. 5/8 5/8 5/8 5/8

1 1 indoor unit and 1 outdoor unit. Note that each unit is individually wrapped.2 Cross-Flow Fan Speeds: (T) Turbo / (H) High / (M) Medium / (L) Low.

Page 3: OTP-B Boreal Ductless Single Zone Heat Pump - Guillevin · OTP-B Boreal. Ductless Single Zone Heat Pump . Operating mode • Cooling and heating. Nominal capacity ... Connection piping

OTP-B

Indoor Unit

Outdoor Unit

Adjustable Wall Bracket for Outdoor Unit

Front View Back ViewSide View

L

A B C

D

H

Front View Top ViewSide ViewSide ViewD L

HA

B

L

H

D

Indoor UnitL H D A B C

in. mm in. mm in. mm in. mm in. mm in. mm

OTP-B09000D-IOTP-B12000D-I

331/4 846 103/4 274 7 178 51/8 130 211/4 541 63/4 173

OTP-B18000D-I 37 940 113/4 297 77/8 201 2 51 27 686 8 203

OTP-B24000D-I 393/4 1008 123/8 315 85/8 218 51/2 140 27 686 71/4 183

Outdoor UnitL H D A B

in. mm in. mm in. mm in. mm in. mm

OTP-B09000D-E 333/8 848 211/4 538 125/8 320 211/4 541 111/4 287

OTP-B12000D-E 333/8 848 231/4 589 125/8 320 211/4 541 111/4 287

OTP-B18000D-E 375/8 955 275/8 701 155/8 396 22 559 141/2 368

OTP-B24000D-E 385/8 980 311/8 790 163/4 427 24 610 153/4 399

Adjustable Wall Bracket

L H D Maximum Capacity

in. mm in. mm in. mm lb kg

OTP-WB3 297/8 759 153/4 400 241/4 616 500 227