GENUINE CABLE GROUP A DIVISION OF EIS, INC. CHICAGO BOSTON ATLANTA PHILADELPHIA DALLAS PHOENIX 847.944.1500 978.534.5300 678.297.1080 215.674.8773 469.467.0480 623.478.8700 [email protected] www.electrowire.com 50 VITALINK ® MC TRANSIT 90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120) FEATURES PERFORMANCE STANDARDS • NFPA 130 - Chapter 12 - exceeds fire resistive requirements • NFPA 502 - Chapter 12 - exceeds fire resistive requirements • New York City Approval • NFPA 70 Article 728 - Electrical Circuit Integrity System 120 • FHIT 120 of the UL Fire Resistance Directory • UL 2196 - Listed as 2-hour fire rated • IEEE 1202/FT4 vertical flame test; ST1 limited smoke • UL 1569 - Listed as Type MC • NFPA 70 Article 330 • UL 2225 - Listed as MC-HL for hazardous locations • Copper sheath exceeds the NEC requirement for equipment grounding conductor Table 250.122 • Copper Conductors to ASTM B8 • 2-hour fire resistance • Splice available • Superior resistance to flame propagation • Only conventional tools required to terminate • Commercially available brass/stainless steel connectors • Printed number coding allows for easy identification (ICEA Method 4) • Labor savings on termination, installation, and handling • Made in USA • Superior impact & crush resistance (hazardous locations) • Low smoke, low toxicity, halogen free design • Welded armor forms an impervious barrier • Armor for equipment grounding • Sunlight Resistant • 90°C for Wet Locations • Flexible • Long continuous lengths available • Multiple sizes and conductor counts available • VFD cable design available APPLICATIONS • NFPA 130, NFPA 502 • Lighting, Ventilation, Communications • NFPA 70/NEC - Articles 695, 700, 728, 760 • NFPA 72, 101 CONSTRUCTION Conductor: Annealed copper Insulation: LSZH ceramifiable silicone Inner Jacket: Ceramifiable silicon rubber bedding layer Armor: Continuously welded and corrugated copper Jacket: Flame resistant low smoke zero halogen (colorable) SCOPE VITALink ® MC is a 600V 2-hour fire rated cable listed to UL2196. It is specifically designed to meet both the electrical and fire-resistive cable requirements of NFPA 130 and NFPA 502 for Emergency Communications, Emergency Lighting & Emergency Ventiliation. When installed per system FHIT 120 and the NEC, VITALink ® MC meets code requirements for 2 hour Fire Rated Circuits, Electrical Cirtcuit Integrity Systems, Survivabilitiy and Circuit Integrity. VITALink ® MC Cables offered lowered cost, reliabilitiy and ease of installation advantages over MI cable and other methods of providing Fire Rated Circuits. The equipment grounding copper armor is terminated with commercially available brass MC connectors and the cable connections are made without the need for splicing or use of special tools. Compared to Mineral Insulated (MI) cable, VITALink ® MC is not exposed to costly field expenses in preparing cable ends, special panel penetrations, additional flexible terminations and the splicing of shorter lengths in longer run. VITALink ® MC is not susceptible to failures caused by moisture ingress through leaky seals or faulty storage.

VITALINK MC TRANSIT - Electro WireVITALink® is a registered trademark RSCC Wire & Cable LLC 90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VITALINK MC TRANSIT - Electro WireVITALink® is a registered trademark RSCC Wire & Cable LLC 90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

GENUINE CABLE GROUP

A DIVISION OF EIS, INC.

CHICAGO BOSTON ATLANTA PHILADELPHIA DALLAS PHOENIX847.944.1500 978.534.5300 678.297.1080 215.674.8773 469.467.0480 623.478.8700

[email protected] www.electrowire.com50

VITALINK® MC TRANSIT90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

FEATURES

PERFORMANCE STANDARDS• NFPA 130 - Chapter 12 - exceeds fire resistive requirements• NFPA 502 - Chapter 12 - exceeds fire resistive requirements• New York City Approval• NFPA 70 Article 728 - Electrical Circuit Integrity System 120• FHIT 120 of the UL Fire Resistance Directory• UL 2196 - Listed as 2-hour fire rated• IEEE 1202/FT4 vertical flame test; ST1 limited smoke• UL 1569 - Listed as Type MC• NFPA 70 Article 330• UL 2225 - Listed as MC-HL for hazardous locations• Copper sheath exceeds the NEC requirement for equipment grounding conductor Table 250.122• Copper Conductors to ASTM B8

• 2-hour fire resistance• Splice available• Superior resistance to flame propagation• Only conventional tools required to terminate• Commercially available brass/stainless steel connectors• Printed number coding allows for easy identification (ICEA Method 4)• Labor savings on termination, installation, and handling• Made in USA• Superior impact & crush resistance (hazardous locations)• Low smoke, low toxicity, halogen free design• Welded armor forms an impervious barrier• Armor for equipment grounding• Sunlight Resistant• 90°C for Wet Locations• Flexible• Long continuous lengths available• Multiple sizes and conductor counts available• VFD cable design available

APPLICATIONS• NFPA 130, NFPA 502• Lighting, Ventilation, Communications• NFPA 70/NEC - Articles 695, 700, 728, 760• NFPA 72, 101

CONSTRUCTIONConductor: Annealed copperInsulation: LSZH ceramifiable siliconeInner Jacket: Ceramifiable silicon rubber bedding layerArmor: Continuously welded and corrugated copperJacket: Flame resistant low smoke zero halogen (colorable)

SCOPEVITALink® MC is a 600V 2-hour fire rated cable listed to UL2196. It is specifically designed to

meet both the electrical and fire-resistive cable requirements of NFPA 130 and NFPA 502 for

Emergency Communications, Emergency Lighting & Emergency Ventiliation. When installed per system FHIT 120 and the NEC, VITALink® MC

meets code requirements for 2 hour Fire Rated Circuits, Electrical Cirtcuit Integrity Systems,

Survivabilitiy and Circuit Integrity. VITALink® MC Cables offered lowered cost, reliabilitiy and ease

of installation advantages over MI cable and other methods of providing Fire Rated Circuits.

The equipment grounding copper armor is terminated with commercially available brass MC connectors and the cable connections are made without the need for splicing or use of special tools. Compared to Mineral Insulated

(MI) cable, VITALink® MC is not exposed tocostly field expenses in preparing cable ends, special panel penetrations, additional flexible

terminations and the splicing of shorter lengths in longer run. VITALink® MC is not susceptible to failures caused by moisture

ingress through leaky seals or faulty storage.

Infra

stru

ctur

e

Page 2: VITALINK MC TRANSIT - Electro WireVITALink® is a registered trademark RSCC Wire & Cable LLC 90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

CHICAGO BOSTON ATLANTA PHILADELPHIA DALLAS PHOENIX847.944.1500 978.534.5300 678.297.1080 215.674.8773 469.467.0480 623.478.8700

[email protected] www.electrowire.comGENUINE CABLE GROUP

A DIVISION OF EIS, INC.

51

GCG Part Number

Cond. Size (AWG)

No. of Cond

Nom.Core Diam

IN

Nom. Armor Diam

IN

Nom. Cable Diam

Over Outer Jacket

Approx Net WtLBS/1000 FT

VTMC-110-001 1/0 1 0.66 1.00 1.11 935

VTMC-210-001 2/0 1 0.70 1.04 1.15 1,050

VTMC-310-001 3/0 1 0.75 1.08 1.18 1,190

VTMC-410-001 4/0 1 0.81 1.16 1.26 1,375

VTMC-250-001 250 1 0.89 1.22 1.32 1,555

VTMC-350-001 350 1 0.99 1.35 1.45 1,955

VTMC-500-001 500 1 1.13 1.50 1.60 2,530

VTMC-750-001 750 1 1.34 1.73 1.85 3,535

VTMC-014-002 14 2 0.49 0.82 0.92 495

VTMC-012-002 12 2 0.53 0.82 0.92 520

VTMC-010-002 10 2 0.58 0.89 0.99 585

VTMC-014-003 14 3 0.52 0.82 0.92 525

VTMC-012-003 12 3 0.56 0.89 0.99 585

VTMC-010-003 10 3 0.61 0.94 1.04 660

VTMC-008-003 8 3 0.72 1.04 1.15 800

VTMC-006-003 6 3 0.80 1.16 1.26 980

VTMC-004-003 4 3 0.91 1.24 1.34 1,210

VTMC-003-003 3 3 0.97 1.30 1.40 1,365

VTMC-002-003 2 3 1.04 1.41 1.51 1,570

VTMC-001-003 1 3 1.21 1.59 1.71 1,945

VTMC-110-003 1/0 3 1.29 1.67 1.79 2,230

VTMC-210-003 2/0 3 1.39 1.80 1.92 2,600

VTMC-310-003 3/0 3 1.49 1.92 2.04 3,030

VTMC-410-003 4/0 3 1.62 2.04 2.16 3,595

VTMC-250-003 250 3 1.80 2.26 2.41 4,275

VTMC-350-003 350 3 2.02 2.48 2.63 5,460

VTMC-500-003 500 3 2.30 2.82 2.97 7,225

VITALINK® MC TRANSIT

* Continued on next page

VITALink® is a registered trademark RSCC Wire & Cable LLC

90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

Page 3: VITALINK MC TRANSIT - Electro WireVITALink® is a registered trademark RSCC Wire & Cable LLC 90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

GENUINE CABLE GROUP

A DIVISION OF EIS, INC.

CHICAGO BOSTON ATLANTA PHILADELPHIA DALLAS PHOENIX847.944.1500 978.534.5300 678.297.1080 215.674.8773 469.467.0480 623.478.8700

[email protected] www.electrowire.com

GCG Part Number

Cond. Size (AWG)

No. of Cond

Nom.Core Diam

IN

Nom. Armor Diam

IN

Nom. Cable Diam

Over Outer Jacket

Approx Net WtLBS/1000 FT

VTMC-014-004 14 4 0.57 0.89 0.99 590

VTMC-012-004 12 4 0.62 0.94 1.04 660

VTMC-010-004 10 4 0.67 1.00 1.11 755

VTMC-008-004 8 4 0.80 1.16 1.26 955

VTMC-006-004 6 4 0.89 1.22 1.32 1,340

VTMC-004-004 4 4 1.00 1.35 1.45 1,450

VTMC-003-004 3 4 1.07 1.41 1.51 1,645

VTMC-002-004 2 4 1.15 1.50 1.60 1,890

VTMC-001-004 1 4 1.34 1.73 1.85 2,375

VTMC-110-004 1/0 4 1.43 1.82 1.94 2,745

VTMC-210-004 2/0 4 1.54 1.95 2.07 3,215

VTMC-310-004 3/0 4 1.68 2.12 2.25 3,830

VTMC-410-004 4/0 4 1.82 2.26 2.41 4,610

VTMC-250-004 250 4 2.00 2.46 2.63 5,365

VTMC-350-004 350 4 2.25 2.71 2.86 6,905

VTMC-500-004 500 4 2.60 3.13 3.30 9,370

VTMC-014-005 14 5 0.63 0.94 1.04 645

VTMC-012-005 12 5 0.68 1.00 1.11 735

VTMC-010-005 10 5 0.74 1.08 1.18 850

VTMC-008-005 8 5 0.88 1.22 1.32 1,075

VTMC-006-005 6 5 0.99 1.30 1.40 1,315

VTMC-004-005 4 5 1.11 1.48 1.58 1,705

VITALINK® MC TRANSIT90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

Page 4: VITALINK MC TRANSIT - Electro WireVITALink® is a registered trademark RSCC Wire & Cable LLC 90ºC • 600V • NEC Type MC UL Listed UL Electrical Circuit Integrity System (FHIT 120)

CHICAGO BOSTON ATLANTA PHILADELPHIA DALLAS PHOENIX847.944.1500 978.534.5300 678.297.1080 215.674.8773 469.467.0480 623.478.8700

[email protected] www.electrowire.comGENUINE CABLE GROUP

A DIVISION OF EIS, INC.